DRAFT8457_E1.pdf
PDF 211 KB Posted
- Attached to
- Fort Leonard Wood MATOC IDIQ
- Solicitation number
- W911S7-23-R-0001
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
D E
S I G
N E
D
C H
E C
K E
D
S U
B M
I T
T E
D
A P
P R
O V
E D
D A
T E
R E
V I S
I O
N S
D I R
E C
T O
R A
T E
O
F
P
U B
L I C
W
R
K S
F O
R
L
O
N A
W
O
D
M
I S
S O
U R
I
D R
A W
N
DATE:
PROJECT NO:
DRAWING NO:
SHEET OF
D A
T E
M A
D E
A P
P R
O V
E D
J
B a l e s
C
E
D B
A
K H
A N
A
K H
A N
J
B
A L E
S
A
L O
P
Z
M
P O
R A
Y
K
T
C H
N
Q U
I P
M E
N T
P L
A N
R E
N O
V A
K
T
C H
N
A
B U
I L
D I N
G
AS SHOWN
07DEC22
M.0118951
FES 08369-1J
8457.12
E1 3
N
E1
MICROWAVE
DISHWASHER
TEMPORARY ARRANGEMENT OF KITCHEN EQUIPMENT IN BUILDING 580
NOT TO SCALE
12'-0"
15'-0"
COOKING RANGE
REFRIGERATOR
REFRIGERATOR
REFRIGERATOR
CKT NO.4/ PANEL-EP-S
CKT NO.6/ PANEL-EP-S
CKT NO.8/ PANEL-EP-S
CKT. NO.8 /PANEL-KP
CKT. NO.3/
PANEL-KP
CKT. NO.5/PANEL-KP
CKT. NO.28/
PANEL-RM
CKT NO.2/PANEL-LP
GENERAL NOTES
1. REFER TO DRW. NO. E2 AND E3 FOR THE RENOVATION OF THE KITCHEN.
2. THIS IS THE TENTATIVE ARRANGEMENT AND THE CONTRACTOR SHALL
MATCH WITHIN THE PLUMBING DRAWING FOR THE FINAL LAYOUT.
3. THE CONTRACTOR SHALL PROVIDE NEW WIRING AND CONDUITS FOR
THE TEMPORARY ARRANGEMENT AND SHALL FOLLOW STRICTLY IEEE
C2,NFPA70,NFPA 72 AND NFPA-101 RULES.
4. THE CONTRACTOR SHALL PROVIDE HEAT DETECTOR IN THE CEILING AS
SHOWN IN THE DRAWING.THE CONTRACTOR SHALL PROGRAM THE
DETECTOR WITH EXISTING FIRE ALARM SYSTEM AND TEST IT WITH THE
10% FIRE ALARM DEVICES IN THE PRESENT OF FIRE DEPARTMENT
PERSONNEL.
5. THE CONTRACTOR SHALL RELOCATE ALL THE EXISTING RECEPTACLES
FROM THE KITCHEN.ALL THE DUPLEX WITHIN THE DISTANCE OF 6'-0"
FROM THE SINK SHALL BE GFCIS.
6. THE CONTRACTOR SHALL FIELD VERIFY THE CIRCUITRY OF THE
EXISTING APPLIANCES,RECEPTACLES AND LIGHTING BEFORE START
THE WORK.
7. SMALL APPLIANCES RECEPTACLES SHALL BE LOCATED AT COUNTER
HEIGH.
8. ALL NEW CONNECTIONS SHALL BE SURFACE MOUNTED.
LEGEND :
G
DUPLEX RECEPTACLES WALL MOUNT
GFCI DUPLEX RECEPTACLES WALL MOUNT
( FOR DISH WASHER UNDER THE COUNTER)
(APPROX)
H
H
NEW HEAT DETECTOR TO BE MOUNTED ON THE CEILING
SINK
SINK
TABLE
TABLE
G
CKT. NO.1 /
PANEL-KP
CKT.NO.6/PANEL-KP
FRYER