DRAFT8457_E1.pdf

PDF 211 KB Posted

Attached to
Fort Leonard Wood MATOC IDIQ
Solicitation number
W911S7-23-R-0001
Issued by

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE:

D E

S I G

N E

D

C H

E C

K E

D

S U

B M

I T

T E

D

A P

P R

O V

E D

D A

T E

R E

V I S

I O

N S

D I R

E C

T O

R A

T E

O

F

P

U B

L I C

W

R

K S

F O

R

L

O

N A

W

O

D

M

I S

S O

U R

I

D R

A W

N

DATE:

PROJECT NO:

DRAWING NO:

SHEET OF

D A

T E

M A

D E

A P

P R

O V

E D

J

B a l e s

C

E

D B

A

K H

A N

A

K H

A N

J

B

A L E

S

A

L O

P

Z

M

P O

R A

Y

K

T

C H

N

Q U

I P

M E

N T

P L

A N

R E

N O

V A

K

T

C H

N

A

B U

I L

D I N

G

AS SHOWN

07DEC22

M.0118951

FES 08369-1J

8457.12

E1 3

N

E1

MICROWAVE

DISHWASHER

TEMPORARY ARRANGEMENT OF KITCHEN EQUIPMENT IN BUILDING 580

NOT TO SCALE

12'-0"

15'-0"

COOKING RANGE

REFRIGERATOR

REFRIGERATOR

REFRIGERATOR

CKT NO.4/ PANEL-EP-S

CKT NO.6/ PANEL-EP-S

CKT NO.8/ PANEL-EP-S

CKT. NO.8 /PANEL-KP

CKT. NO.3/

PANEL-KP

CKT. NO.5/PANEL-KP

CKT. NO.28/

PANEL-RM

CKT NO.2/PANEL-LP

GENERAL NOTES

1. REFER TO DRW. NO. E2 AND E3 FOR THE RENOVATION OF THE KITCHEN.

2. THIS IS THE TENTATIVE ARRANGEMENT AND THE CONTRACTOR SHALL

MATCH WITHIN THE PLUMBING DRAWING FOR THE FINAL LAYOUT.

3. THE CONTRACTOR SHALL PROVIDE NEW WIRING AND CONDUITS FOR

THE TEMPORARY ARRANGEMENT AND SHALL FOLLOW STRICTLY IEEE

C2,NFPA70,NFPA 72 AND NFPA-101 RULES.

4. THE CONTRACTOR SHALL PROVIDE HEAT DETECTOR IN THE CEILING AS

SHOWN IN THE DRAWING.THE CONTRACTOR SHALL PROGRAM THE

DETECTOR WITH EXISTING FIRE ALARM SYSTEM AND TEST IT WITH THE

10% FIRE ALARM DEVICES IN THE PRESENT OF FIRE DEPARTMENT

PERSONNEL.

5. THE CONTRACTOR SHALL RELOCATE ALL THE EXISTING RECEPTACLES

FROM THE KITCHEN.ALL THE DUPLEX WITHIN THE DISTANCE OF 6'-0"

FROM THE SINK SHALL BE GFCIS.

6. THE CONTRACTOR SHALL FIELD VERIFY THE CIRCUITRY OF THE

EXISTING APPLIANCES,RECEPTACLES AND LIGHTING BEFORE START

THE WORK.

7. SMALL APPLIANCES RECEPTACLES SHALL BE LOCATED AT COUNTER

HEIGH.

8. ALL NEW CONNECTIONS SHALL BE SURFACE MOUNTED.

LEGEND :

G

DUPLEX RECEPTACLES WALL MOUNT

GFCI DUPLEX RECEPTACLES WALL MOUNT

( FOR DISH WASHER UNDER THE COUNTER)

(APPROX)

H

H

NEW HEAT DETECTOR TO BE MOUNTED ON THE CEILING

SINK

SINK

TABLE

TABLE

G

CKT. NO.1 /

PANEL-KP

CKT.NO.6/PANEL-KP

FRYER

Sheets and Views
8457_E1-DEMOLITION PLAN