This is a technical specifications document (Exhibit E) for hazardous chemical and radiochemical analytical laboratory services prepared by Brookhaven National Laboratory's Environmental Protection Division, dated January 26, 2026.
The document establishes comprehensive quality control requirements and detection limits for 46 analytical methods spanning organic compounds, metals, radiochemical parameters, and specialty analyses. For organic analyses, the contractor laboratory must set recovery control limits with a minimum acceptable threshold of 10%. Key organic methods include EPA Method 624.1/SW-846 8260D for volatile organic compounds (detection limits 0.5–10 ug/L depending on analyte), EPA Method 524.3 for drinking water organics (0.5 ug/L), EPA Method 625/SW-846 8270E for semivolatile compounds (10–50 ug/Kg), and EPA Method 608.3/SW-846 8081B for organochlorine pesticides and PCBs (0.05–2.5 ug/L). Metal analysis utilizes EPA Methods 200.7, 200.8, 6010C, and 6020A via ICP techniques with detection limits ranging from 0.2 to 200 ug/L. Radiochemical analyses include isotopic tritium, gross alpha/beta, strontium-89/90, radium-226/228, technetium-99, uranium isotopes, plutonium isotopes, americium-241, and curium isotopes, each with specified pCi/L or pCi/g detection limits and QA/QC requirements. Gamma spectroscopy includes five reporting subsets (Remediation, Surveillance, BGRR, TPL/BLIP, and Building 811) with radionuclide-specific detection limits and search libraries. Additional specialized methods address PFAS/PFOA compounds (EPA Methods 537.1, 533, 1633A), hexavalent chromium (Method 218.6), dioxins (Method 613), and asbestos (Method 198.2). All methods reference specific EPA or ASTM standards and require documented quality control including method blanks, duplicates, matrix spike/spike duplicates, calibration checks, and precision/accuracy validation per individual method specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DRAFT Exhibit B 2026.pdf | ||
| DRAFT Exhibit F and Tech.pdf | ||
| DRAFT Exhibit D.pdf | ||
| DRAFT Exhibit C and Qualifiers 2026.pdf | ||
| DRAFT Exhibit A 2026.pdf | ||
| DRAFT Exhibit H 2026.pdf | ||
| DRAFT Exhibit G 2026.pdf | ||
| DRAFT Fee Schedule.xlsx | XLSX spreadsheet | |
| DRAFT SOW 26 Jan 2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit E Technical Specifications for Hazardous Chemical and Radiochemical Analytical Laboratory
Services - Part I
DRAFT
Exhibit E
Technical Specifications For Hazardous Chemical and Radiochemical
Analytical Laboratory Services Part I
January 26, 2026
Prepared by: Environmental Protection Division
Brookhaven National Laboratory Upton, NY 11973-5000
Section I - Analytical Method Specifications
The following section lists the required QC for analysis for selected methods and the full data package deliverables. Whenever practical, the analyte lists contained in the PDF copies of the data packages should be numbered. For organic analyses where the contractor laboratory is responsible for setting the recovery control limits for various quality control checks (i.e. lab control samples, surrogate recoveries, etc.), the minimal acceptable control limit cannot be lower than 10%.
1. Method 624.1 or SW-846 (8260D):
References:
Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater- EPA 600/4-82-057, Method 624, Federal Register, Vol. 49, No.209, p. 43373, October 26, 1984.
Method 624.1-Purgeables by GC/MS EPA 821-R-16-008, December 2016 Test Methods for Evaluation of Solid Waste, SW-846 manual, Method 8260.
U.S. EPA. 2006. "Method 8260D (SW-846): Volatile Organic Compounds by Gas Chromatography/Mass Spectrometry
(GC/MS)," Revision 3. Washington, DC
QA/QC required:
Please see Section 9 (Quality Control) of Method 8260D for QC requirements Please see Section 8 (Quality Control) of Method 624.1 for QC requirements
Deliverables:
Please see Exhibit G
Methods 624, SW-846 (8260D) Low Level(LL), and SW-846 (8260D) analytes and detection limits
PARAMETER CAS# REQUIRED DETECTION LIMITS
(ug/L, ug/L, ug/Kg) *
1. Benzene 71-43-2 0.5/5/5
2. Bromodichloromethane 75-27-4 0.5/5/5
3. Bromoform 75-25-2 0.5/5/5
4. Bromomethane 74-83-9 0.5/10/10
5. Carbon tetrachloride 56-23-5 0.5/5/5
6. Chlorobenzene 108-90-7 0.5/5/5
7. Chloroethane 75-00-3 0.5/10/10
8. 2-Chloroethylvinyl ether 110-75-8 1/10/10
9. Chloroform 67-66-3 0.5/5/5
10. Chloromethane 74-87-3 0.5/10/10
11. Dibromochloromethane 124-48-1 0.5/5/5
12. 1,2-Dichlorobenzene 95-50-1 0.5/5/5
13. 1,3-Dichlorobenzene 541-73-1 0.5/5/5
14. 1,4-Dichlorobenzene 106-46-7 0.5/5/5
15. 1,1-Dichloroethane 75-34-3 0.5/5/5
16. 1,2-Dichloroethane 107-06-2 0.5/5/5
17. 1,1-Dichloroethylene 75-35-4 0.5/5/5
18. trans-l,2-Dichloroethylene 540-59-0 0.5/5/5
19. 1,2-Dichloropropane 78-87-5 0.5/5/5
20. cis-l,3-Dichloropropylene 10061-01-5 0.5/5/5
21. trans-l,3-Dichloropropylene 10061-02-6 0.5/5/5
22. Ethyl benzene 100-41-4 0.5/5/5
23. Methylene chloride 75-09-2 0.5/5/5
24. 1,1,2,2-Tetrachloroethane 79-34-5 0.5/5/5
25. Tetrachloroethylene 127-18-4 0.5/5/5
26. Toluene 108-88-3 0.5/5/5
27. 1,1,1-Trichloroethane 71-55-6 0.5/5/5
28. 1,1,2-Trichloroethane 79-00-5 0.5/5/5
29. Trichloroethylene 79-01-6 0.5/5/5
30. Trichlorofluoromethane 75-69-4 0.5/5/5
31. Vinyl chloride 75-01-4 0.5/10/10
32. acetone 67-64-1 10
33. carbon disulfide 75-15-0 5
34. 2-butanone 78-93-3 10
35. vinyl acetate 108-05-4 10 36.2-hexanone 591-78-6 10
37. 4-methyl-2-pentanone 108-10-1 10
38. MTBE 1634-04-4 0.5/5/10
* The detection limits (DL) listed are for low-level water, water and low-level soils, respectively. However, DLs could be appropriately higher for medium/ high level soils and for samples requiring dilution.
** Due to the higher method detection limits, these methods are unsuitable for DMR SPDES samples.
2. EPA Method 524.3:
Reference:
Methods for the Determination of Organic Compounds in Drinking Water: EPA 815-B-09-009 June 2009.
QA/QC required:
Please see Section 9 (Quality Control) of Method 524.3 for QC requirements
Deliverables:
Please see Exhibit G
Method 524.3 analytes & detection limits:
PARAMETER CAS# REQUIRED DETECTION LIMITS (ug/L) benzene 71-43-2 0.5 bromobenzene 108-86-1 0.5 bromochloromethane 74-97-5 0.5 bromodichloromethane 75-27-4 0.5 bromoform 75-25-2 0.5 bromomethane 74-83-9 0.5 n-butylbenzene 104-51-8 0.5 sec-butylbenzene 135-98-8 0.5 tert-butylbenzene 98-06-6 0.5 carbon tetrachloride 56-23-5 0.5 chlorobenzene 108-90-7 0.5 chloroethane 75-00-3 0.5 chloroform 67-66-3 0.5 chloromethane 74-87-3 0.5 2-chlorotoluene 95-49-8 0.5 4-chlorotoluene 106-43-4 0.5 dibromochloromethane 124-48-1 0.5 1,2-dibromo-3-chloropropane 96-12-8 0.5 1,2-dibromoethane 106-93-4 0.5 dibromomethane 74-95-3 0.5 1,2-dichlorobenzene 95-50-1 0.5 1,3-dichlorobenzene 541-73-1 0.5 1,4-dichlorobenzene 106-46-7 0.5 dichlorodifluoromethane 75-71-8 0.5 1,1-dichloroethane 75-34-3 0.5 1,2-dichloroethane 107-06-2 0.5 l,l-dichloroethene 75-35-4 0.5 cis-l,2-dichloroethene 156-59-2 0.5 trans-l,2-dichloroethene 540-59-0 0.5 1,2-dichloropropane 78-87-5 0.5 1,3-dichloropropane 142-28-9 0.5 2,2-dichloropropane 594-20-7 0.5 l,l-dichloropropene 563-58-6 0.5 cis-l,2-dichloropropene 6923-20-2 0.5 trans-l,2-dichloropropene 7069-38-7 0.5 ethylbenzene 100-41-4 0.5 hexachlorobutadiene 87-68-3 0.5 isopropylbenzene 98-82-8 0.5 4-isopropyltoluene 99-87-6 0.5 methylene chloride 75-09-2 0.5 naphthalene 91-20-3 0.5 propylbenzene 103-65-1 0.5 styrene 100-42-5 0.5 1,1,1,2-tetrachloroethane 630-20-6 0.5 1,1,2,2-tetrachloroethane 79-34-5 0.5 tetrachloroethene 127-18-4 0.5 toluene 108-88-3 0.5 1,2,3-trichlorobenzene 87-61-6 0.5 1,2,4-trichlorobenzene 120-82-1 0.5 l,l,l-trichloroethane 71-55-6 0.5 1,1 ,2-trichloroethane 79-00-5 0.5 trichloroethene 79-01-6 0.5 trichlorofluoromethane 75-69-4 0.5 1,2,3-trichloropropane 96-18-4 0.5 1,2,4-trimethylbenzene 526-73-8 0.5 1,3,5-trimethylbenzene 108-67-8 0.5 vinyl chloride 75-01-4 0.5 o-xylene 95-47-6 0.5 m-xylene 108-38-3 0.5 p-xylene 106-42-3 0.5
MTBE 1634-04-4 0.5
I
3. EPA method 502.2:
Reference:
Methods for the Determination of Organic Compounds in Drinking Water: EPA 600/R-95-131 August 1995.
QA/QC required:
Please see Section 9 (Quality Control) of Method 502.2 for QC requirements
Deliverables:
Please see Exhibit G
Method 502.2 analytes & detection limits:
PARAMETER CAS# REQUIRED DETECTION LIMITS (ug/L)
Benzene 71-43-2 0.5 bromobenzene 108-86-1 0.5 bromochloromethane 74-97-5 0.5 bromodichloromethane 75-27-4 0.5 bromoform 75-25-2 0.5 bromomethane 74-83-9 0.5 n-butylbenzene 104-51-8 0.5 sec-butylbenzene 135-98-8 0.5 tert-butylbenzene 98-06-6 0.5 carbon tetrachloride 56-23-5 0.5 chlorobenzene 108-90-7 0.5 chloroethane 75-00-3 0.5 chloroform 67-66-3 0.5 chloromethane 74-87-3 0.5 2-chlorotoluene 95-49-8 0.5 4-chlorotoluene 106-43-4 0.5 dibromochloromethane 124-48-1 0.5 1,2-dibromo-3-chloropropane 96-12-8 0.5 1,2-dibromoethane 106-93-4 0.5 dibromoethane 74-95-3 0.5 1,2-dichlorobenzene 95-50-1 0.5 1,3-dichlorobenzene 541-73-1 0.5 1,4-dichlorobenzene 106-46-7 0.5 dichlorodifluoromethane 75-71-8 0.5 l,l-dichloroethane 75-34-3 0.5 1,2-dichloroethane 107-06-2 0.5 l,l-dichloroethene 75-35-4 0.5 cis-l,2-dichloroethene 6923-20-2 0.5 trans-l,2-dichloroethene 540-59-0 0.5 1,2-dichloropropane 78-87-5 0.5 1,3-dichloropropane 142-28-9 0.5 2,2-dichloropropane 594-20-7 0.5 l,l-dichloropropene 563-58-6 0.5 cis-l,2-dichloropropene 6923-20-2 0.5 trans-l,2-dichloropropene 7069-38-7 0.5 ethylbenzene 100-41-4 0.5 hexachlorobutadiene 87-68-3 0.5 isopropylbenzene 98-82-8 0.5 4-isopropyltoluene 99-87-6 0.5 methylene chloride 75-09-2 0.5 naphthalene 91-20-3 0.5 propylbenzene 103-65-1 0.5 styrene 100-42-5 0.5 1,1,1,2-tetrachloroethane 630-20-6 0.5 1,1,2,2-tetrachloroethane 79-34-5 0.5
PARAMETER CAS# REQUIRED DETECTION LIMITS (ug/L) tetrachloroethene 127-18-4 0.5 toluene 108-88-3 0.5 1,2,3-trichlorobenzene 87-61-6 0.5 1,2,4-trichlorobenzene 120-82-1 0.5 l,l,l-trichloroethane 71-55-6 0.5 1,1,2-trichloroethane 79-00-5 0.5 trichloroethene 79-01-6 0.5 trichlorofluoromethane 75-69-4 0.5 1,2,3-trichloropropane 96-18-4 0.5 1,2,4-trimethylbenzene 526-73-8 0.5 1,3,5-trimethylbenzene 108-67-8 0.5 vinyl chloride 75-01-4 0.5 o-xylene 95-47-6 0.5 m-xylene 108-38-3 0.5 p-xylene 106-42-3 0.5
MTBE 1634-04-4 0.5
Freon 113 76-13-1 1.0
*Method 524.3 can be substituted for Method 502.2 provided all analytes and Limits are meet
4. EPA Method 504.1 and EPA Method 8011:
Methods for the Determination of Organic Compounds in Drinking Water: EPA 600/R-95-131 August 1995.
SW-846 Compendium Method 8011: USEPA July 1992
QA/QC required:
Please see Section 9 (Quality Control) of Method 504.1 for QC requirements Please see Section 8 (Quality Control) of Method 8011 for QC requirements
Method 504.1 and Method 8011 analyte & detection limit:
PARAMETER CAS# DETECTION LIMIT (ug/L)
1,2-dibromoethane 106-93-4 0.02 1,2-dibromo-3-chloropropane 96-12-8 0.05
5. EPA Method 505.2 (chlorinated pesticides)
Reference:
Methods for the Determination of Organic Compounds in Drinking Water: EPA 600/R-95-131 March 1995.
QA/QC required:
Please see Section 9 (Quality Control) of Method 505.2 for QC requirements
EPA Method 505.2 analytes & method detection limits:
PARAMETER CAS DETECTION LIMITS (ug/L) aldrin 309-00-2 0.05 chlordane-alpha 5103-71-9 0.05 chlordane-gamma 5103-74-2 0.05 endrin 72-20-8 0.10 heptachlor 76-44-8 0.05 heptachlor epoxide 1024-57-3 0.05 lindane 58-89-9 0.05 methoxychlor 72-43-5 0.50 toxaphene 8001-35-2 1.0 dieldrin 60-57-1 0.10 propachlor 1918-16-7 0.5 PCBs (total) OER-101-88 0.5
6. EPA Method 515 (chlorinated acids):
Methods for the Determination of Organic Compounds in Drinking Water: EPA 600/4-88/039 December 1988.
Water: EPA 600/R-92/129 August 1992- Supplement 2.
Water - Supplement III (EPA/600/R-95-131)
Methods for the Determination of Organic and Inorganic Compounds in Drinking Water, Volume 1 (EPA/815-R-00-014)
Please see Section 9 (Quality Control) of Method 515 for QC requirements
EPA Method 515 analytes & detection limits:
PARAMETER CAS# DETECTION LIMITS (ug/L)
2,4-D 94-75-7 0.50 2,4,5-TP (silvex) 93-72-1 0.50 dalapon 75-99-0 5.0 dicamba 1918-00-9 0.50 dinoseb 88-85-7 0.50 pentachlorophenol 87-86-5 0.10 picloram 1918-02-1 0.50
7. EPA Method 522 (1,4-Dioxane):
METHOD 522 DETERMINATION OF 1,4-DIOXANE IN DRINKING WATER BY SOLID PHASE EXTRACTION (SPE) AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) WITH SELECTED ION MONITORING (SIM):
EPA/600/R-08/101, September 2008.
Please see Section 9 (Quality Control) of Method 522 for QC requirements
Method 522 analyte & detection limit:
PARAMETER CAS# DETECTION LIMIT (ug/L)
1,4-Dioxane 123-91-1 0.1
8. EPA Method 525.3 (extractable compounds by GC/MS including nitrogen & Phosphorus containing pesticides):
Methods for the Determination of Organic Compounds in Drinking Water: EPA 600/4-88/039 December 1988.
Methods for the Determination of Organic Compounds in Drinking Water - Supplement III (EPA/600/R-95-131)
National Service center for Environmental Publications (NSCEP) (EPA/600/R-12/010)
Please see Section 9 (Quality Control) of Method 525.3 for QC requirements
EPA METHOD 525.3 analytes & detection limits:
PARAMETER CAS# DETECTION LIMITS (ug/L)
Alachlor 15972-60-8 1.0 atrazine 1912-24-9 0.5 benzo(a)pyrene 50-32-8 5.0 butachlor 23184-66-9 1.0 di-(2-ethylhexyl)adipate 103-23-1 5.0 di-(2-ethylhexyl)phthalate 117-81-7 5.0 hexachlorobenzene 118-74-1 1.0 hexachlorocyclopentadiene 77-47-4 1.0 metolachlor 51218-45-2 1.0 metribuzin 21087-64-9 0.5 simazine 122-34-9 0.5
9. Method 625 or SW-846 (8270D):
References:
Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater- EP A 600/4-82-057, Method 625, Federal Register, Vol. 49, No.209, pp 43385, October 26, 1984.
Method 625.1-Base/Neutrals and Acids by GC/MS USEPA, December 2016
Test methods for Evaluating Solid Waste, SW-846 Methods, U.S. EPA. 2014. "Method 8270E (SW-846): Semivolatile Organic Compounds by Gas Chromatography/ Mass Spectrometry (GC/MS)," Washington, DC
QA/QC required:
Please see Section 9 (Quality Control) of Method 8270E for QC requirements Please see Section 8 (Quality Control) of Method 625.1 for QC requirements
Method 625 and SW-846 (8270) Analytes & Detection Limits
PARAMETER CAS# REQUIRED DETECTION LIMITS
(ug/L or ug/Kg)*
1. Acenaphthene 83-32-9 10/330
2. Acenaphthylene 208-96-8 10/330
3. Anthracene 120-12-7 10/330
4. Aldrin 309-00-2 (#)
5. Benzo(a)anthracene 56-55-3 10/330
6. Benzo(b)fluoranthene 205-99-2 10/330
7. Benzo(k)fluoranthene 207-08-9 10/330
8. Benzo(a)pyrene 50-32-8 10/330
9. Benzo(ghi)perylene 191-24-2 10/330
10. Benzyl butyl Phthalate 85-68-7 10/330
11. beta-BHC 319-85-7 (#)
12. delta- BHC 319-86-8 (#)
13. Bis(2-chloroethyl) ether 111-44-4 10/330
14. Bis(2-chloroethoxy)methane 111-91-1 10/330
15. bis(2-ethylhexyl)phthalate 117-81-7 10/330
16. Bis(2-chloroisopropyl)ether 39638-32-9 10/330
17. 4-Bromophenyl phenylether 101-55-3 10/330
18. chlordane 57-74-9 (#)
19. 2-Chloronaphthalene 91-58-7 10/330
20. 4-Chlorophenyl phenyl ether 7005-72-3 10/330
21. Chrysene 218-01-9 10/330
22. 4,4'-DDD 72-54-8 (#)
23. 4,4'-DDE 72-55-9 (#)
24. 4,4'-DDT 50-29-3 (#)
25. Dibenzo(a,h)anthracene 53-70-3 10/330
26. Di-n-butylphthalate 84-74-2 10/330
27. 1,3-Dichlorobenzene 541-73-1 10/330
28. 1,2-Dichlorobenzene 95-50-1 10/330
29. 1,4-Dichlorobenzene 106-46-7 10/330
30. 3,3'-Dichlorobenzidine 91-94-1 40/1300
31. Dieldrin 60-57-1 (#)
32. Diethyl phthalate 84-66-2 10/330
33. Dimethyl phthalate 131-11-3 10/330
34. 2,4-Dinitrotoluene 121-14-2 10/330
35. 2,6-Dinitrotoluene 606-20-2 10/330
36. Di-n-octylphthalate 117-84-0 10/330
37. Endosulfan sulfate 1031-07-8 (#)
38. Endrin aldehyde 7421-93-4 (#)
39. Fluoranthene 206-44-0 10/330
40. Fluorene 86-73-7 10/330
41. Heptachlor 76-44-8 (#)
42. Heptachlorepoxide 1024-57-3 (#)
43. Hexachlorobenzene 118-74-1 10/330
44. Hexachlorobutadiene 87-68-3 10/330
45. Hexachloroethane 67-72-1 10/330
46. Indeno(1,2,3-cd)pyrene 193-39-5 10/330
47. Isophorone 78-59-1 10/330
48. Naphthalene 91-20-3 10/330
49. Nitrobenzene 98-95-3 10/330
50. N-Nitroso-di-n-propylamine 621-64-7 10/330
51. PCB-1016 12674-11-2 (#)
52. PCB-1221 11104-28-2 (#)
53. PCB-1232 11141-16-5 (#)
54. PCB-1242 53469-21-9 (#)
55. PCB-1248 12672-29-6 (#)
56. PCB-1254 11097-69-1 (#)
57. PCB-1260 11096-82-5 (#)
58. Phenanthrene 85-01-5 10/330
59. Pyrene 129-00-0 10/330
60. Toxaphene 8001-35-1 (#)
61. 1,2,4-Trichlorobenzene 120-82-1 10/330 62.4-Chloro-3-methylphenol 59-50-7 10/330
63. 2-Chlorophenol 95-57-8 10/330
64. 2,4-Dichlorophenol 120-83-2 10/330
65. 2,4-Dimethylphenol 105-67-9 10/330
66. 2,4-Dinitrophenol 51-28-5 50/1700
67. 2-Methyl-4,6-dinitrophenol 534-52-1 50/1700
68. 2-Nitrophenol 88-75-5 10/330
69. 4-Nitrophenol 100-02-7 50/1700
70. Pentachlorophenol 87-86-5 50/1700
71. Phenol 108-95-2 10/330
72. 2,4,6- Trichlorophenol 88-06-2 10/330
73. alpha- BHC 319-84-6 (#)
74. gamma- BHC 58-89-9 (#)
75. Endosulfan-l 959-98-8 (#)
76. Endosulfan- 2 33213-65-9 (#)
77. Endrin 72-20-8 (#)
78. Hexachlorocyclopentadiene 77-74-4 10/330
79. N-Nitrosodimethylamine 62-75-9 10/330
80. N-Nitrosodiphenylamine 86-30-6 10/330
81. 1,4-Dioxane by SIM 123-91-1 0.1
(#) compounds may be analyzed by methods 608 or SW-846 (8081) with lower detection limits (see methods 608 and 8081 required detection limits). However, if concentration of anyone of these compounds in the ~ is more than 10 ug/ml, confirmation by GCMS is required-
* The detection limits (DL) listed are for water and low-level soils, respectively. However, DLs could be appropriately higher for medium/ high level soils and for samples requiring dilution.
10. Method 608.3 and SW-846 (8081B and 8082A):
Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater- EPA 600/4-82-057, Method 608, Federal Register, Vol. 49, No.209, October 26, 1984, pp 43321.
U.S. EPA. 2016. EPA 821-R-16-009 "Method 608.3: Organochlorine Pesticides and PCBs by GC/HSD" Washington, DC
December 2016
Test Methods for Evaluating Solid Waste, SW-846 Methods, Method 8081B: Organochlorine Pesticides by Gas Chromatography, part of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, February 2007.
Method 8082A: Polychlorinated Biphenyls (PCB) by Gas Chromatography, part of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, February 2007
QA/QC required:
Please see Section 8 (Quality Control) of Method 608.3 for QC requirements Please see Section 9 (Quality Control) of Method 8081B for QC requirements Please see Section 9 (Quality Control) of Method 8082A for QC requirements
Deliverables:
Please see Exhibit G
Method 608 or SW-846 (8081B):
PARAMETER CAS# REQUIRED DETECTION LIMITS (ug/L or ug/Kg)* Aldrin 309-00-2 0.05/1.7 beta- BHC 319-85-7 0.05/1.7 delta- BHC 319-86-8 0.10/3.3 chlordane 57-74-9 0.05/1.7
4,4'-DDD 72-54-8 0.05/1.7
4,4'-DDE 72-55-9 0.10/3.3
Dieldrin 60-57-1 0.10/3.3
4,4.- DDT 50-29-3 0.10/3.3
Endosulfan sulfate 1031-07-8 0.10/3.3 Endrin aldehyde 7421-93-4 0.10/3.3 Endrin ketone 53494-70-5 0.10/3.3 Heptachlor 76-44-8 0.05/1.7 Heptachlor epoxide 1024-57-3 0.05/1.7 alpha- BHC 319-84-6 0.05/1.7 gamma- BHC 58-89-9 0.05/1.7 Endosulfan- 1 959-98-8 0.05/1.7 Endosulfan- 2 33213-65-9 0.10/3.3 Endrin 72-20-8 0.10/3.3 Methoxychlor 72-43-5 0.50/17.0 Toxaphene 8001-35-2 2.5/170
PCB-1016** 12674-11-2 0.065/33.0
PCB-1221 ** 11104-28-2 0.065/67.0
PCB-1232** 11141-16-5 0.065/33.0
PCB-1242** 53469-21-9 0.065/33.0
PCB-1248** 12672-29-6 0.065/33.0
PCB-1254** 11097-69-1 0.065/33.0
PCB-1260** 11096-82-5 0.065/33.0
* For water and low-level soils, respectively. The detection limits will be higher for medium/high level soils and samples requiring dilution.
** For method 608 Flora and Fauna only.
10 Method 608 or SW-846 (8082A):
PARAMETER CAS# REQUIRED DETECTION LIMITS (ug/L or ug/Kg)*
PCB-1016 12674-11-2 0.065/33.0
PCB-1221 11104-28-2 0.065/67.0
PCB-1232 11141-16-5 0.065/33.0
PCB-1242 53469-21-9 0.065/33.0
PCB-1248 12672-29-6 0.065/33.0
PCB-1254 11097-69-1 0.065/33.0
PCB-1260 11096-82-5 0.065/33.0
* PCBs in oil must have a detection limits at a maximum of 2 mg/kg.
11. EPA Method 531.2 (carbamate pesticides):
Reference:
Methods for the Determination of Organic Compounds in Drinking
Water - Supplement III (EPA/600/R-95-131).
EPA Method 531.2 Measurement of N-methylcarbamoyloximes and N-methylcarbamates in WATER by Direct Aqueous Injection HPLC with Postcolumn Derivatization (EPA 815-B-01-002) September 2001
Please see Section 9 (Quality Control) of Method 531.2 for QC requirements
Deliverables:
Please see Exhibit G
EPA METHOD 531.2 analytes & detection limits:
PARAMETER CAS# DETECTION LIMITS (ug/L) aldicarb 116-06-3 < 5.0 aldicarb sulfoxide 1646-87-3 < 5.0 aldicarb sulfone 1646-88-4 < 5.0 carbofuran 1563-66-2 < 5.0 carbaryl 63-25-2 < 5.0 methomyl 16752-77-5 < 5.0 3-hydroxycarbofuran 16655-82-6 < 5.0 oxamyl-(vydate) 23135-22-0 < 5.0
12. EPA METHOD 547 (GLYPHOSATE):
Reference:
Water: EPA 600/4-90/020.July 1990- Supplement 1.
Please see Section 10 (Quality Control) of Method 547 for QC requirements
EPA METHOD 547 analyte & detection limit:
PARAMETER CAS DETECTION LIMIT (ug/L) glyphosate 1071-83-6 10
13. EPA METHOD 548.1 (ENDOTHALL):
Water: EPA 600/4-90/020 July 1990- Supplement- 1.
Water - Supplement II (EPA/600/R-92-129) August 1992
Please see Section 9 (Quality Control) of Method 548.1 for QC requirements
EPA METHOD 548.1 analyte & detection limit:
PARAMETER CAS DETECTION LIMIT (ug/L) endothall 145-73-3 25
14. EPA METHOD 549.2 (diquat)
Reference:
Water: EPA 600/4-90/020 July 1990. Supplement- 1.
Please see Section 9 (Quality Control) of Method 549.2 for QC requirements
EPA METHOD 549.2 analyte & detection limit:
diquat 85-00-7 5.0
15. Metals:
Methods for chemical analysis of water and wastes- EPA-600/4- 79-020- Revised March 1983 -see Appendix 8 for individual method references.
Methods for the determination of metals in environmental samples- EPA-600/4-91-010- June 1991, method 200.7 using ICP-OES.
Method 200.7, Revision 4.4: Determination of Metals and Trace Elements in Water and Wastes by Inductively Coupled Plasma- Atomic Emission Spectrometry. USEPA 1994
Methods for the determination of metals in environmental water, waste and potable water samples, method 200.8 Method 200.8, Revision 5.4: Determination of Trace Elements in Waters and Wastes by Inductively Coupled Plasma-Mass Spectrometry. USEPA 1994 Method 245.1: Methods for the Determination of Metals in Environmental Samples, Supplement 1 (EPA/600/R-94/111) Method 245.2: Methods for the Chemical Analysis of Water and Wastes (MCAWW) (EPA/600/4-79/020) Method 245.7: Mercury in Water by Cold Vapor Atomic Fluorescence Spectrometry, Revision 2.0, February 2005, (EPA-821-R-05-001) SW-846 Test Method 6010D: Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES). USEPA July 2018 SW-846 Test Method 6020B: Inductively Coupled Plasma- Mass Spectrometry. USEPA July 2014
SW-846 Test Method 7000B: Flame Atomic Absorption Spectrophotometry. USEPA February 2007
SW-846 Test Method 7010: Graphite Furnace Atomic Absorption Spectrophotometry. USEPA February 2007
SW-846 Test Method 7470A: Mercury in Liquid Waste (Manual Cold-Vapor Technique). USEPA September 1994
SW-846 Test Method 7471B: Mercury in solid or Semisolid Waste (Manual Cold-Vapor Technique). USEPA February 2007
Method 1631, Revision E: Mercury in Water by Oxidation, Purge and Trap, and Cold Vapor Atomic Fluorescence Spectrometry.
EPA-821-R-02-019. U.S. Environmental Protection Agency, Office of Water, August 2002, 38 p
QA/QC required:
Please see the Quality Control section of the above reference methods for QC requirements
Deliverables:
Please see Exhibit G
Metals:
Element Method # Required Detection Limit (ug/L)*
Aluminum 200.9(STGFAA), 202.1(AAS) 200
200.7, 200.8 or 6010C, 6020A 15
Antimony 200.7, 200.8 or 6010, 6020 3
200.9 (STGFAA) 3
Arsenic 200.9 (STGFAA), 1 200.7, 200.8 or 6010C, 6020A 2
Barium 200.7, 200.8 or 6010C, 6020A 0.8
Beryllium 200.7, 200.8 or 6010C, 6020A 0.2
Cadmium 200.7, 200.8 or 6010C, 6020A 0.5
Calcium 200.7, 200.8 or 6010C, 6020A 50
Chromium 200.7, 200.8 or 6010C, 6020A 0.5
Cobalt 200.7, 200.8 or 6010C, 6020A 1
Copper 200.7, 200.8 or 6010C, 6020A 1
Iron 200.7, 200.8 or 6010C, 6020A 5
Lead 200.7, 200.8 or 6010C, 6020A 1 Element Method # Required Detection Limit (ug/L)*
Magnesium 200.7, 200.8 or 6010C, 6020A 25
Manganese 200.7, 200.8 or 6010C, 6020A 0.5
Mercury 245.1, 245.2, or 245.7 0.1
7470A, 7471B 0.1
Mercury (low level) 1631 0.001
Nickel 200.7, 200.8 or 6010C, 6020A 2
Potassium 200.7, 200.8 or 6010C, 6020A 20
Selenium 200.7, 200.8 or 6010C, 6020A 2
Silver 200.7, 200.8 or 6010C, 6020A 0.5
Sodium 200.7, 200.8 or 6010C, 6020A 15
Thallium 200.7, 200.8 or 6010C, 6020A 0.5
Vanadium 200.7, 200.8 or 6010C, 6020A 2 zinc 200.7, 200.8 or 6010C, 6020A 1
* These detection limits will be correspondingly high for soils and other samples with matrix problems, and for samples requiring dilutions.
AAS= Atomic Absorption Spectroscopy GFAA= Graphite Furnace Atomic Absorption ICP= Inductively Coupled Plasma Optical Emission Spectrometry
16. Method 1631 (Methyl Mercury)
References:
Test Methods for Evaluating Solid Waste, SW-846 Methods, Method 1631
QA/QC required:
Please see Section 9 (Quality Control) of Method 1631 for QC requirements
17. Method 1311, Toxicity Characteristic Leaching Procedure (TCLP) Organic and Inorganic
Federal Register: II Hazardous Management System; Identification and Listing of Hazardous Waste; Toxicity Characteristic revisions." Vol. 55, NO.61, pp 117P7-11877 (March 29, 1990) and Vol. 126, pp 26986-26998 (June 29,1990). i
Test Methods for Evaluation of Solid Waste, third edition, SW-846 method 1311.
QA/QC required:
Please see Section 8 (Quality Control) of Method 1311, in addition to the required analytical method quality control, for QC requirements
Required detection limit – 0.02 ng/L
TCLP Analytes and Required Detection Limits (SW-846 Method 1311):
PARAMETER CAS# DETECTIQN LIMIT ( mg/L)
1) benzene 71-43-2 0.05
2) carbon tetrachloride 56-23-5 0.05
3) chlordane 57-74-9 0.015
4) chlorobenzene 108-90-7 10
5) chloroform 67-66-3 0.60
6) o-cresol 95-48-7 20
7) m-cresol 108-39-4 20
8) p-cresol 106-44-5 20
9) 1,4-dichlorobenzene 106-46-7 0.75
10) 1,2-dichloroethane 107-06-2 0.05
11) 1,1-dichloroethylene 540-59-0 0.07
12) 2,4-dinitrotoluene 121-14-2 0.01
13) hexachlorobenzene 118-74-1 0.01
14) hexachloro-l,3-butadiene 87-68-3 0.05
15) hexachloroethane 67-72-1 0.30
16) methyl ethyl ketone 78-93-3 20
17) nitrobenzene 98-95-3 0.20
18) pentachlorophenol 87-86-5 10
19) pyridine 110-86-1 0.50
20) tetrachloroethylene 127-18-4 0.07
21) trichloroethylene 79-01-6 0.05
22) 2,4,5-trichlorophenol 95-95-4 40
23) 2,4,6-trichlorophenol 88-06-2 0.20
24) vinyl chloride 75-01-4 0.02
25) arsenic 0.50
26) barium 10 27)cadmium 0.10
28) chromium 0.50 29 lead 0.50
30) mercury 0.02
31) selenium 0.10
32) silver 0.50
33) heptachlor 76-44-8 0.004
34) heptachlor epoxide 1024-57-3 0.004
35) endrin 72-20-8 0.005
36) lindane 58-89-9 0.04
37) methoxychlor 72-43-5 1.0
38) toxaphane 8001-35-2 0.10
39) 2,4-D 94-75-7 1.0
40) 2,4,5- TP (silvex) 93-72-1 0.1
18. Method 1312, Synthetic Precipitation Leaching Procedure (SPLP) Organic and Inorganic Reference:
SW-846 Test Method 1312: Synthetic Precipitation Leaching Procedure, part of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods. September 1994
QA/QC required:
Please see Section 8 (Quality Control) of Method 1312, in addition to the required analytical method quality control, for QC requirements
Required detection limit – 0.02 ng/L PFAS/PFOA required detection limit- 10 ppt
*PFAS/PFOA compounds are considered semivolatiles
SPLP Analytes and Required Detection Limits (SW-846 Method 1312):
1) benzene 71-43-2 0.05
2) carbon tetrachloride 56-23-5 0.05
3) chlordane 57-74-9 0.015
4) chlorobenzene 108-90-7 10
5) chloroform 67-66-3 0.60
6) o-cresol 95-48-7 20
7) m-cresol 108-39-4 20
8) p-cresol 106-44-5 20
9) 1,4-dichlorobenzene 106-46-7 0.75
10) 1,2-dichloroethane 107-06-2 0.05
11) 1,1-dichloroethylene 540-59-0 0.07
12) 2,4-dinitrotoluene 121-14-2 0.01
13) hexachlorobenzene 118-74-1 0.01
14) hexachloro-l,3-butadiene 87-68-3 0.05
15) hexachloroethane 67-72-1 0.30
16) methyl ethyl ketone 78-93-3 20
17) nitrobenzene 98-95-3 0.20
18) pentachlorophenol 87-86-5 10
19) pyridine 110-86-1 0.50
20) tetrachloroethylene 127-18-4 0.07
21) trichloroethylene 79-01-6 0.05
22) 2,4,5-trichlorophenol 95-95-4 40
23) 2,4,6-trichlorophenol 88-06-2 0.20
24) vinyl chloride 75-01-4 0.02
25) arsenic 0.50
26) barium 10 27)cadmium 0.10
28) chromium 0.50 29 lead 0.50
30) mercury 0.02
31) selenium 0.10
32) silver 0.50
33) heptachlor 76-44-8 0.004
34) heptachlor epoxide 1024-57-3 0.004
35) endrin 72-20-8 0.005
36) lindane 58-89-9 0.04
37) methoxychlor 72-43-5 1.0
38) toxaphane 8001-35-2 0.10
39) 2,4-D 94-75-7 1.0
40) 2,4,5- TP (silvex) 93-72-1 0.1
41) PFOS 1763-23-1 (10 ppt)
45) PFOA 335-67-1 (10 ppt)
19. Wet Chemistry Methods:
The following reference is applicable for the parameters listed below. Any other equivalent method (eg: Standard Methods 23rd edition) may be used provided required detection limits and QA/QC are met and method used is identified.
Methods for Analysis of Water and Wastes- Revised March 1983. EPA-600/4-79-020, unless otherwise stated.
Please see the Quality Control section of the above reference methods for QC requirements
PARAMETER Method # REQUIRED DETECTION LIMIT
(mg/L)
1) Alkalinity 2320B 1.0
2) ammonia-N 350.1/4500 0.05 ammonia (NH3) 4500 20 ug/L
3) bromide 300 0.02
4) chloride 300 1.0 chloride (Cl) 4500 (IC) 10
5) hexavalent chromium 7196A 0.010
PARAMETER Method # REQUIRED DETECTION LIMIT
(mg/L)
6) TKN 351 0.10
7) TOC 5310/9060A 1.0
8) COD 410 1.0
9) BODs 5120 1.0
10) ortho-phosphate-P 365 0.2 11 phenol 420 0.01
12) chloride 300 1.0
13) sulfate 300 5.0 sulfate 4500 or 4110 (IC) 0.5
14) sulfide 4500 0.1
15) cyanide 335, 9010 0.01 cyanide (CN) 4500 10
16) total suspended solids 2540 2.0
17) turbidity 180 0.1 NTU
18) oil & grease 664A 5.0
19) total petroleum hydrocarbons (TPH) 418.1, ASTM D7678-11 1.0
20) methylene blue active substances (MBAS) 425 10 ug LAS detergents (MBAS) 5540 50 ug/L
21) Total Phosphorous 365.3 0.20
22) Residual chlorine 4500-Cl- 0.10
23) pH 9040C 0.1 units pH (waste/soil) 9045D 0.1 units pH (H+) 4500 0.1 units
24) nitrite-N 300, 353.2 0.005 nitrite as N (N02) 4500 or 4110 (IC) 0.5
25) nitrate-N 353 0.005 nitrate as N (N03) 4500 or 4110 (IC) 0.5
26) Total Nitrogen M4500-N 0.1
27) Nitrate-nitrite (as N) 300, 353.2 0.1
28) Salinity 2520 0.1
29) color 2120 5 units
30) specific conductivity 2510 100 µmhos
31) fluoride (F) 4500 0.1
32) odor 2150 odor units
33) total calcium (Ca) 3500 0.5
34) Cation exchange capacity 9081
35) Clay content ------ %
Reference for Corrosivity and Ignitability:
Corrosivity Method 1110 Ignitability Method 1010 or 1020
* The MDLs required for cyanide and sulfide are:
cyanide (water/soil) 0.05 mg/L and 25 mg/Kg, respectively sulfide (water/soil) 1.0 mg/L and 50 mg/Kg, respectively.
20. EPA Method 198.2 Asbestos:
Standard Methods for the Examination of Water and Wastewater, 23th edition (2017)- method 2570 (transmission electron microscopy) Item 198.1. 198.6, 198.4, 198.8 of manual (EPA 600/M4/82/020)
Minimum QA/QC required:
1) routine instrument calibration and documentation of results
2) recounting of at least 10 t of samples
3) blank checks
1) chain-of-custody
2) analytical results for all samples containing:
asbestos concentration in structures/L total and fibrous asbestos structures > 10 micron in length types of asbestos present number of asbestos structures counted effective filtration area average size of TEM grid openings counted number of grid openings examined size category for each structure counted PDF copy of the TEM count sheet
3) blank analysis data
4) duplicate analysis data
5) PDF copy of instrument calibration results (annual)
EPA METHOD 198.2 analyte & detection limit:
PARAMETER CAS DETECTION LIMIT
(MF/L)
Asbestos OER-200-004 0.68
21. Method 9020B Total Organic Halides (TOX):
Water: Test Methods for Evaluation of Solid Waste -SW-846 manual, method 9020B.
Oils: Test Methods for Evaluation of Solid Waste 1- SW-846 manual, Proposed Update II. Method 9076 (or an equivalent method which can provide an MDL of 10 ppm and meet required QC as described below).
Minimum Detection Limit:
Water: 50 ug/L
Oil: 10 ug/g
QA/QC required:
Please see Section 8 (Quality Control) of Method 9020B for QC requirements
22 Method 2510 Conductivity:
Standard Methods for the Examination of Water and Wastewater, 23th edition (2017)- method 2510
2) method blank analysis
3) one duplicate analysis per sampling event on BNL sample
2) analytical results for all samples reported as µmhos/cm 25.0°C
3) blank analysis data
4) duplicate analysis data
5) PDF copy of instrument calibration results
6) PDF copy of instrument logbooks.
METHOD 2510 analyte & detection limit:
PARAMETER DETECTION LIMIT
Conductivity 100 µmhos/cm
23 pH:
Standard Methods for the Examination of Water and Wastewater, 23th edition (2017)- method 4500/9040C/9045D
2) method blank analysis
3) one duplicate analysis per sampling event on BNL sample
2) analytical results for all samples reported as 0.1 units
3) blank analysis data
4) duplicate analysis data
5) PDF copy of instrument calibration results
6) PDF copy of instrument logbooks.
Analyte & detection limit:
PARAMETER DETECTION LIMIT
pH 0.1 units
24 Fecal & Total Coliform:
New York State Environmental Laboratory Approval Program (ELAP) Certification Manual- Item No. 245.
Standard Methods for the Examination of Water and Wastewater, 23th edition (2017).
Methods: part 9000 (microbiological examination of water) in general, and 9200 series methods using either
a) multiple-tube fermentation (MPN), or
b) membrane filtration (MF) technique.
Please see Part 9000 Microbiological Examination (9020 Quality Control) of Method 9020B for QC requirements
Deliverables:
1) chain-of-custody with signature, date & time of sample collection and receipt
2) case narrative describing any deviations from prescribed protocols, analytical problems, QC violations and other relevant information
3) analysis report for all samples with BNL ID, reference method used, method detection limit, matrix, and date analyzed
4) PDF copies of logbooks.
5) record of date/time of sample(s) preparation, incubation time and temperature etc.
25 RCRA Parameters for Oil samples (for burning):
The following parameters are to be analyzed under this category.
References:
1) Test Methods for Evaluation of Solid Waste, SW-846, Third edition. The respective methods for metals and detection limits for each parameter are given below.
2) Test Methods for Evaluation of Solid Waste, SW-846, third edition- for TOX in oils: Proposed Update 11, Method 9076(or an equivalent which can provide an MDL of 10 ppm and meet required QC as described below).
3) EPA 600/4-81-045 (9/82- The determination of polychlorinated biphenyls in transformer fluid and waste oils.
Parameter Test Methods (ref.1) Detection limit (ppm)
Prep Analysis
Arsenic 3040/3050 7060 0.5 Cadmium 3040/3050 6010/7131 0.2 Chromium 3040/3050 6010/7191 1.0 Lead 3040/3050 6010/7420/7421 1.0 Flash point 1010 -- Total organic halogens Section.2 10 PCB Section 6 2.0 Sulfur ASTM D4294 or D2622 0.5 % Gross Heat Content ASTM D240 or D4809 12500 BTU/Ga1
TOX ASTM D 808-81
QA/QC required:
Please see the Quality Control section of the above reference methods for QC requirements
26 Lead in paint samples:
Reference and detection limit:
Test Methods for Evaluating Solid Waste, SW-846 methods, third edition.
Parameter Method Detection Limit. (mg/Kg) total lead 7421 1.0 TCLP lead 1311/6010/7470 0.5
QA/QC required:
Please see the Quality Control section of the above reference methods for QC requirements
27 Method- 615 or SW-846 (8151A):
References:
Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater- EPA 600/4-82-057, Method 615, Federal Register, Vol. 49, No.209, October 26, 19r4, pp. 43321. ; Test Methods for Evaluating Solid Waste, SW-846; Methods, Third Edition, Method 8151A.
QA/QC required:
Please see Section 8 (Quality Control) of Method 8151A for QC requirements Please see Section 8 (Quality Control) of Method 615 for QC requirements
Deliverables:
Please see Exhibit G
Method- 615 and SW-846 (8151A) analyte & detection limit::
PARAMETER CAS # REQUIRED DETECTION LIMITS - (ug/L or ug/Kg)*
2,4 -D 94- 75-7 0.25/8.2
2,4-DB 94-82-6 0.25/8.2
2,4,5-TP 93-72-1 0.25/8.2
2,4,5-T 93-76-5 0.25/8.2 Da1apon 75-99-0 0.25/8.2 Dicamba 1918-00-9 0.25/8.2 Dich1oroprop 120-36-5 0.25/8.2 Dinoseb 88-85-7 0.25/8.2
MCPA 94-74-6 0.25/8.2
MCPP 93-65-2 0.25/8.2
4-Nitrophenol 100-02-1 0.25/8.2 Pentachlorophenol 87-86-5 0.25/8.2
28 Method 314: References:
Method 314.0 Determination of Perchlorate in Drinking Water using Ion Chromatography, November 1999, Revision 1.0
QA/QC required:
Please see Section 9 (Quality Control) of Method 314 for QC requirements
Deliverables:
Please see Exhibit G
Methods 314 analyte & detection limit
PARAMETER REQUIRED DETECTION LIMITS
(ug/L)
1. Perchlorate 1.0
29 Isotopic Tritium
Introduction
Low energy beta particle counting in a cocktail vial with liquid scintillation counter (LSC) shall be used for tritium analysis.
Sample shall be extracted by distillation method, and LSC calibrated with NIST traceable source. QA/QC samples shall be analyzed with the SDG.
References:
HASL 300, Chieco, N.A., Bogen, D.C., and E.O. Knutson, eds. EML Procedures Manual, 27th Edition, Volume 1, New York, Environmental Measurements Laboratory, U.S. Department of Energy, HASL 300, 1990.
Krieger, H. L., Whittaker, E. L. Prescribed procedures for measurement of radioactivity in drinking water. Cincinnati, OH:
Office of Research and Development, U.S. Environmental Protection Agency, EPA-600/4-80-032, 1980.
Contract Method Detection Limits:
Tritium 500 pCi/L water and 500 pCi/g for soil.
Certification with NYS DOH Efficiency/quench curves shall be established at least semiannually for each radionuclide to be counted, with daily verification checks.
Each batch shall contain a batch blank vial that will be used for blank subtraction.
Batch calibration for background and efficiency at a frequency as required by the SOP method Continuing calibration checks at a frequency as required by the method or once per day, whichever is more frequent.
Method blank processed in each batch.
A batch matrix spike (MS) and matrix spike duplicate (MSD) per batch of 20 samples.
Laboratory control sample (one per batch, minimum)
Summary data packages are required and include:
Original chain-of-custody Formal analysis report for all samples showing ID#, date, result, uncertainty and MDC.
Method blank data. MDC of 500 pCi/L is required for H3.
Laboratory control sample data. Recovery must be 75-125%.
For matrix spike dups, precision must be within 20% and accuracy within 20%.
Full data packages may be requested (on a select basis) and will include QA/QC data not provided in Summary packages:
Trending analyses for calibration and QC standards are maintained by contractor laboratory and can be made available upon request.
Initial and continuing calibration data, precision and accuracy results (obtained from MS and MSD samples) maintained by the contractor laboratory.
Excel raw data spreadsheets for sample analyses Log-book records.
30 Gross Alpha/Beta
Introduction
Low background proportional counting system shall be used for gross alpha/beta analysis. The system shall be calibrated with NIST traceable source and efficiency curves shall be generated using tap water residue for range of precipitate weights that will be utilized for counting planchet. The gross alpha counting shall be analyzed such that the sample residue density does not exceed 5 mg/sq.cm.
HASL 300, Chieco, N.A., Bogen, D.C., and E.O. Knutson, eds. EML Procedures Manual, 27th Edition, Volume 1, New York, Environmental Measurements Laboratory, U.S. Department of Energy, HASL 300, 1990.
Krieger, H. L., Whittaker, E. L. Prescribed procedures for measurement of radioactivity in drinking water. Cincinnati, OH:
Office of Research and Development, U.S. Environmental Protection Agency, EPA-600/4-80-032, 1980.
Contract Method Detection Limits:
Gross alpha – 2.0 pCi/L (water) and 1.0 pCi/g (soil, oil, etc) Gross beta – 4 pCi/L (water) and 1.0 pCi/g (soil, oil, etc)
1000-minute minimum background counts shall be performed at least monthly.
Daily background checks shall be performed.
Detector efficiency shall be determined at least annually with recalibration performed when daily checks fail the acceptance criteria.
Detector efficiency checks shall be performed daily before use.
Mass attenuation curves shall be generated at least annually.
Voltage plateau curve determinations shall be performed at least annually with performance check performed after each gas bottle change or maintenance activity.
Cross talk determination shall be made at least annually Continuing calibration checks at a frequency as required by the method or daily, whichever is more frequent.
Method blank processed in each batch.
A batch matrix spike (MS) and matrix spike duplicate (MSD) per batch of 20 samples.
Copy of chain-of-custody Formal analysis report for all samples showing ID#, date, result, uncertainty and MDC.
Method blank data. MDC of 3E-4 pCi/L for gross alpha and 1 pCi/L for gross beta are required.
Laboratory control sample data. Recovery must be 75-125%.
For matrix spike dups, precision must be within 20% and accuracy within 20%.
Full data packages may be requested (on a select basis) and will include QA/QC data not provided in Summary packages (See Attachment 1):
Trending analyses for calibration and QC standards are maintained by contractor laboratory and can be made available upon request.
Initial and continuing calibration data, precision and accuracy results (obtained from MS and MSD samples) maintained by the contractor laboratory.
31 Isotopic Strontium
HASL 300, Chicago, N.A., Bogen, D.C., and E.O. Knutson, eds. EML Procedures Manual, 27th Edition, Volume 1, New York, Environmental Measurements Laboratory, U.S. Department of Energy, HASL 300, 1990.
Krieger, H. L., Whittaker, E. L. Prescribed procedures for measurement of radioactivity in drinking water. Cincinnati, OH:
Office of Research and Development, U.S. Environmental Protection Agency, EPA-600/4-80-032, 1980.
Sr-89 -5 pCi/L for water and 5 pCi/g for soil/sludge Sr-90 -0.8 pCi/L for water 7.5 pCi/g for soil/sludge
Batch calibration for background and efficiency at a frequency as required by the SOP method Continuing calibration at a frequency as required by the SOP method Method blank processed in each batch.
A batch matrix spike (MS) and matrix spike duplicate (MSD) per batch of 20 samples.
Copy of chain-of-custody Formal analysis report for all samples showing ID#, date, result, uncertainty and MDC.
Method blank data. MDC of 2E-10 uCi/cc air for Sr-90 is required.
Laboratory control sample data. Recovery must be 75-125%.
For matrix spike dups, precision must be within 20% and accuracy within 20%.
Full data packages may be requested (on a select basis) and will include QA/QC data not provided in Summary packages (See Attachment 1):
Trending analyses for calibration and QC standards are maintained by contractor laboratory and can be made available upon request.
Initial and continuing calibration data, precision and accuracy results (obtained from MS and MSD samples) maintained by the contractor laboratory.
32 Radiological Parameter: Radium-226 and Radium 228
References:
For drinking water:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 903.0,903.1 or DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML
Method Ra-03 or Standard Methods for the Examination of Water and Wastewater, 19th edition, Std. Method 750-Ra B.
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Section 8, Radium-228 in Drinking Water Method 904.0
For soils/sludges:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 901.1 or DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML Method
Ra-03, 04.
Contract Method Detection Limits:
Radium-226 -2.0 pCi/L for water (alpha spectroscopy only) and 0.5 pCi/g for soil.
Minimum QC Requirements:
1) background measurements and calibration check using NIST traceable standards for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes using NIST traceable standards
3) 5% of water and wastewater samples to include field and laboratory blanks
4) 6 month holding time
5) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Chain-of-custody with signature, date & time of sample collection and receipt Case narrative describing any deviations from prescribed protocols, analytical problems, QC violations and other relevant information Analysis report for all samples with BNL ID, reference method used, method detection limit, matrix, and date analyzed Copies of raw data output from GeLi or Alpha Spectrometer counter Copies of calibration curves, NIST traceable source certificate, and calibration factor calculations Control charts of background measurements and calibration checks using NIST traceable standards along with the associated
Quality Control limits.
Quality control results and associated acceptance criteria for control spike, matrix spikes, duplicates and field/laboratory blanks.
33 Radiological Parameter: Technicium-99
References:
For drinking water:
DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML Method Tc- 01-RC. DOE Method RD 550-I, revision 1 November 1999. For soils/sludge’s: ASTM C1387, “Standard Guide for the Determination of Technetium-99 in Soil technicium-99 -379 pCi/L for water, 15 pci/g for soil
Minimum QC Requirements:
I) background measurements and calibration check using NIST traceable standards for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes using NIST traceable standards
3) 5% of water and wastewater samples to include field and laboratory blanks
4) 6 month holding time
5) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Chain-of-custody with signature, date & time of sample collection and receipt Case narrative describing any deviations from prescribed protocols, analytical problems, QC violations and other relevant information Analysis report for all samples with BNL ID, reference method used, method detection limit, matrix, and date analyzed Copies of raw data output from liquid scintillation Ci>n counter Copies of quench curves, NIST traceable source certificate, and calibration factor calculations Control charts of background measurements and calibration checks using NIST traceable standards along with the associated
Quality control results and associated acceptance criteria for control spikes, duplicates, matrix spikes, and field/laboratory blanks.
34 Radiological Parameter: Uranium-234/235/238
For drinking water:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 908.0 or DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML Method
U-02-RC, U-04, or ASTM D3972-09.
For soils/sludges:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 907.0 or DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML Method U-02-RC, U- 04.
Contract Method Detection Limits:
Uranium-234/235/238 -26 pCi/L in water and 0.9 pCi/g for soil. Minimum QC Requirements:
1) Background measurements and calibration check for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes
3) 5% of water and wastewater samples to include field and laboratory blanks
4) 6 month holding time
5) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Copy of chain-of-custody Formal analysis report for all samples showing ID#, date, result, uncertainty and MDC.
Method blank data. MDC of 2E-8 pCi/L for both U-235 and U-238.
Laboratory control sample data. Recovery must be 75-125%.
For matrix spike dups, precision must be within 20% and accuracy within 20%.
Full data packages may be requested (on a select basis) and will include QA/QC data not provided in Summary packages:
Trending analyses for calibration and QC standards are maintained by contractor laboratory and can be made available upon request.
Initial and continuing calibration data, precision and accuracy results (obtained from MS and MSD samples) maintained by the contractor laboratory.
35 Radiological Parameter: Plutonium-238/239/240
For drinking water: Not applicable.
For soils/sludges:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 907.0 or DOE's Environmental Measurement Laboratory's HASL-300 Procedures Manual, February 1992, EML Method
Pu-02-RC, 03, ASTM Method P3865-90
Contract Method Detection Limits:
Plutonium-238/239/240 -6.6,4.0,4.0 pCi/g, respectively for soil.
Plutonium-238/239/240 -0.7, 6.0, 6.0 pCi/L, respectively for water
Minimum QC Requirements:
I) background measurements and calibration check using NIST traceable standards for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes using NIST traceable standards
3) 6 month holding time
4) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Chain-of-custody with signature, date & time of sample collection and receipt Case narrative describing any deviations from prescribed protocols, analytical problems, QC violations and other relevant information Analysis report for all samples with BNL ID, reference method used, method detection limit, matrix, and date analyzed Copies of raw data output from alpha spectrometer counter Copies of calibration curves, NIST traceable source certificate, and calibration factor calculations Control charts of background measurements and calibration checks using NIST traceable standards along with the associated
Quality control results and associated acceptance criteria for control spikes, matrix spikes and duplicates.
36 - Radiological Parameter: Plutonium-239, 240
Inductively Coupled Plasma Mass Spectroscopy ICP/MS
For drinking water: Not applicable.
For soils/sludges:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 907.0 or DOE's Environmental Measurement Laboratory HASL-300 Procedures Manual, February 1992, EML Method
Pu-02-RC, 03.
Contract Method Detection Limits:
Plutonium-239, 240- 1 pCi/L for aqueous samples and 1 pCi/g for solid samples
Minimum QC Requirements:
1) background measurements and calibration check using NIST traceable standards for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes using NIST traceable standards
4) 6 month holding time
5) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Chain-of-custody with signature, date & time of sample collection and receipt Case narrative describing any deviations from prescribed protocols, analytical problems, QC violations and other relevant information Analysis report for all samples with BNL ID, reference method used, method detection limit, matrix, and date analyzed Copies of raw data output from alpha spectrometer counter Copies of calibration curves, NIST traceable source certificate, and calibration factor calculations Control charts of background measurements and calibration checks using NIST traceable standards along with the associated
Quality control results and associated acceptance criteria for control spikes, matrix spikes and duplicates.
37 Radiological Parameter: Americium-241
For drinking water:
Prescribed Procedures for Measurement of Radioactivity in Drinking Water, EPA-600/4-80-032, August 1980, Method 907.0. DOE: Environmental Measurement Laboratory, HASL-300 Procedure Manual, February 1992, EML Method Am-
03-RC.
For soils/sludges:
DOE's Environmental Measurement Laboratory's lIASL-300 Procedures Manual, February 1992, EML Methods Am-01, 02.
Contract Method Detection Limits:
Americium-241 -0.6 pCi/L for water by alpha spectroscopy. , 25 pCi/L for water and 4.0 pCi/g for soil by gamma spectroscopy.
Minimum QC Requirements:
I) background measurements and calibration check using NIST traceable standards for each batch
2) 5% of samples to be analyzed will include duplicates, matrix spikes, and control spikes using NIST traceable standards
3) 5% of water and wastewater samples to include field and laboratory blanks
4) 6 month holding time
5) 90 % data completeness +/-25% accuracy and ~ 35% precision.
Deliverables:
Chain-of-custody with signature, date & time of…