Hawaii
Job Corps Center Waimanalo, HI
Facility Planning Report Volume II
Supporting Data
Final June 2009
Department of Labor/ Office of Job Corps
Hawaii
Job Corps Center Waimanalo, HI
Facility Planning Report Volume II
Supporting Data
Final June 2009
Male and Female Dorm Building 7
• Building Condition by Function
• Building Condition Site Plan
VOLUME II - Supporting Data
• VICINITY MAP
• LOCATION MAP
• EXISTING SITE PLAN
D. DESCRIPTIONS
• Program Descriptions
— Square Footage Details (GSF by Building, Space Utilization Comparison, NSF by Building)
— Energy Management
— Environmental Management (Environmental Management Report and Radon Report)
• Site Descriptions
• Building Descriptions
E. DEFICIENCIES
F. CORRESPONDENCE AND REPORTS
• Center Review Brief
• Survey Brief
• RA and Student Facility Feedback Questionnaire
• Life Safety Defi ciencies Transmittal and List
• O & M Defi ciency List
• Active Warranty Report
• FRPC Performance Measures Matrix
VOLUME I - Planning Strategy
• Existing Site Plan
• Center Statistics
INTRODUCTION
• Purpose
• Report Contents
EXECUTIVE SUMMARY
• Signifi cant Issues
• Recommended Plan
• Summary of Proposed Projects
A. EXISTING CONDITIONS
• Background
• General Site Conditions
• General Building Conditions
• Ownership
• Facility Assessment by Function
• Energy
• Environmental Issues
• Sustainability
• Accessibility Standards
• Current and Completed Projects Since the Last Survey
• Health and Life Safety Issues
• Summary of Defi ciencies
B. RECOMMENDATIONS
• Status of the Previous (PY05) Plan
• Issues
• PY 08 Plan Overview
• Regional Projects
• Proposed Site Plan
C. PLANNING ANALYSIS
• Purpose
• Planning Objectives and Assumptions
• Space Utilization Analysis
• Federal Real Property Asset Management
• Mission Dependency Site Plan
• Defi ciency Analysis
• Facility Condition Summary Report
CONTENTS
HAWAII JOB CORPS CENTER
FACILITY PLANNING REPORT
D Descriptions
BUILDINGS AND STRUCTURES
00903 HAWAII 04-JUN-09
1Page:
0001 - GATEHOUSE
0002 - ADMINISTRATION
0002A - MEDICAL/DENTAL
0003 - EDUCATION CENTER
0004 - HARD VOC/WARE HOUSE/OACTS
0005 - DINING/CULINARY ARTS
0006 - RECREATION/GROUP LIFE
0007 - MALE AND FEMALE DORM
0008 - CHILD DEVELOPMENT CENTER
0009 - Pavilion #1 0010 - Pavilion #2 0011 - Pavilion #3 0012 - Pavilion #4
0014 - STORAGE CONTAINER #2
0017 - STORAGE CONTAINER #5
0019 - OIL STORAGE
0020 - EQUIPMENT STORAGE
0023 - STORAGE CONTAINER #7
0028 - DORMITORY STORAGE
0029 - STORAGE
Name GSF
5,434 2,516
10,760 15,485 9,260
11,100 29,876 5,055
Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
StatusType
Building Building Building Building Building Building Building Building Building Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure
Use Group Built Flrs Const
Business Business Business Business Factory/Ind.
Assembly Assembly Residential Business Assembly Assembly Assembly Assembly Storage Storage Storage Storage Storage Storage Storage
Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good
ConditionAsset Number
0090300044 0090300045 0090308053 0090300046 0090300047 0090300048 0090300049 0090300050 0090300051 0090300052 0090300053 0090300054 0090300055 0090300056 0090300060 0090308038 0090308039 0090308042 0090308047 0090308054
9 89,766
11 3,160
20 92,926
Buildings
Structures
Total
GSF
GSF
GSF
Summary
June 04, 2009 Space Utilization By Function 00903 Hawaii
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 210 Non Residents 40
250Total Students
(210)
(250)
(250)
DIFFERENCE
21,000
17,300
4,500
27,640
23,545
6,530
Lounge Other Shower/Toilet Sleeping Storage
Academic (250) Non-Academic
8 -- ACT (Off-Ctr) 20 -- Auto Repair Tech/Helper + 90 -- Business Office Technologies 20 -- Culinary Arts + 24 -- Facilities Maint. and Const. + 30 -- Health Occupations + 24 -- Landscaping +
6 -- OCT
24 -- Painting +
Dining (2 Servings) Food Preparation Food Storage
2,460 1,180 4,310
16,410 3,280
3,255 7,425
2,840 2,055 1,730 1,780
1,780
1,815
3,965 1,950
2,100
2,520 15,120 1,260
2,500 2,500
1,500 3,600 1,200 1,800 1,200 1,200
1,800
2,000 1,500 1,000
1,790 1,290 2,020
4,925
1,340 -1,545
-20
-335
1,965 -385
Vocations
6,640
6,245
2,030
June 04, 2009 Space Utilization By Function 00903 Hawaii
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 269.06 67,265 79,168
(250)
(250)
(250)
(250)
DIFFERENCE
89,766
0.88
TOTAL GSF
NET TO GROSS RATIO
11,100
1,445
6,920
5,000
5,981
1,904
8,984
4,584
Arts & Crafts Assembly Hall Hospitality Centers Miscellaneous Recreation Non-Resident Lounge Pool Hall Recreation Room Recreation Storage Weight Room
Medical/Dental
Administration Child Development Center (24)
Operations & Maintenance Warehouse
5.78
1,770
1,490
1,904
4,434 4,550
2,114 2,470
1,445
5,000 1,920
2,000 3,000
-566 2,630
-530
RESIDENT
NON-RESIDENT
(210)
(40) 15
50 10,500
-5,119
2,064
-416
11,903
Net Square Footage By Building Date: 06/04/2009 Page: 1Center: HAWAII (00903)
HOUSING
EDUCATION
Sleeping
Lounge
Storage
Shower/Toilet
Other
Academic
Health Occupations
Culinary Arts
Painting
Facilities Maint. and Const.
Landscaping
Non-Academic
Business Office Technologie
Auto Repair Tech/Helper
Function Suggested NSF
16,410
2,460
3,280
4,310
1,180
1,085
1,730
1,815
1,780
1,780
2,000
1,475
1,310
2,055
2,840
0007 - MALE AND FEMALE DORM
0007 - MALE AND FEMALE DORM
0007 - MALE AND FEMALE DORM
0007 - MALE AND FEMALE DORM
0007 - MALE AND FEMALE DORM
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0005 - DINING/CULINARY ARTS
0004 - HARD VOC/WARE HOUSE/OACTS
0004 - HARD VOC/WARE HOUSE/OACTS
0004 - HARD VOC/WARE HOUSE/OACTS
0003 - EDUCATION CENTER
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0003 - EDUCATION CENTER
0004 - HARD VOC/WARE HOUSE/OACTS
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0003 - EDUCATION CENTER
0004 - HARD VOC/WARE HOUSE/OACTS
Bldg Name Actual NSF Difference
16,410
2,460
3,280
4,310
1,180
3,255
1,730
1,815
1,780
1,780
7,425
2,055
2,840
Sub Total:
Sub Total:
27,640
23,545
15,120
2,100
1,260
2,520
2,500
1,200
1,200
1,800
1,800
1,200
2,500
3,600
1,500
21,000
17,300
1,290
2,020
1,790
1,180
-335
-20
4,925
-1,545
1,340
6,640
6,245
Page: 2Center: HAWAII (00903)
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
Dining (2 Servings)
Food Preparation
Food Storage
Arts & Crafts
Weight Room
Miscellaneous Recreation
Pool Hall
Assembly Hall
Hospitality Centers
Recreation Room
Non-Resident Lounge
Recreation Storage
Medical/Dental
Administration
Child Development Center
Function Suggested NSF
3,965
1,950
1,490
1,770
1,904
4,200
4,550
0005 - DINING/CULINARY ARTS
0005 - DINING/CULINARY ARTS
0005 - DINING/CULINARY ARTS
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0006 - RECREATION/GROUP LIFE
0002A - MEDICAL/DENTAL
0001 - GATEHOUSE
0002 - ADMINISTRATION
0008 - CHILD DEVELOPMENT CENTER
Bldg Name Actual NSF Difference
3,965
1,950
1,490
1,770
1,904
4,434
4,550
Sub Total:
Sub Total:
Sub Total:
Sub Total:
6,530
5,981
1,904
8,984
2,000
1,500
1,000
1,445
5,000
1,920
4,500
11,100
1,445
6,920
1,965
-385
-566
2,630
2,030
-5,119
2,064
Page: 3Center: HAWAII (00903)
STORAGE/SUPPORT
Warehouse
Operations & Maintenance
Function Suggested NSF
2,470
1,910
0004 - HARD VOC/WARE HOUSE/OACTS
0004 - HARD VOC/WARE HOUSE/OACTS
0006 - RECREATION/GROUP LIFE
Bldg Name Actual NSF Difference
2,470
2,114
Sub Total: 4,584
3,000
2,000
5,000
-530
( 250
-416
Energy Management Report
Center: HAWAII (00903) Page: 1 Date: 06/04/2009
CENTER ENERGY DATA
Deferred (new center)
ENERGY CONSUMPTION STATISTICS
23.8 64,904 36,700 52,429
ENERGY USE BY FUEL TYPE
Energy Audit :
Date of Audit :
Electric Company :
1985 Baseline :
2005 Goal (30% Reduction) :
Current Consumption Rate :
Percent Change :
Average Program Goal :
Natural Gas Company :
Property Status :
N/A
Hawaiian Electric Company Airgas Gaspro
Leased
1,207,441 4,120=
Total 5,826
MBtu
MBtu
Total $287,776 MBtu/ $49.395
88,276
Btu/GSF/YR Btu/GSF/YR Btu/GSF/YR
Btu/GSF/YR
Data from the most recent four quarters
Electricity
Propane kWh
17,868 Gal = 1,706 MBtu
$241,706 $0.200= kWhElectricity
Propane $46,070 = $2.578 Gal
ENERGY COST BY FUEL TYPE
COMMENTS
2/01- Controlling A/C units, Controlling appliances, Controlling kitchen appliances
Page: 2 Date: 06/04/2009
Implementing some of the below recommendations can save you 10% to 25% off your annual energy bill without negatively impacting comfort or productivity.
1. Your staff and students are the key to savings. Educate the students and staff on the why of energy saving - costs and environmental impacts. Encouraging them to actively participate in energy reduction is also important. Post reminders at exit doors and bulletin boards about energy conservation. Simple tips include:
a. Turn it down (lights, heating & cooling),
b. Turn it off (lights, computers, other equipment),
c. Keep it tight (close doors and windows, use window blinds)
2. Operations and Maintenance: Educate the O&M staff on the why of energy saving -costs and environmental impacts. Simple tips include:
a. Make sure that the Operations and Maintenance staff is properly trained for the equipment they operate.
b. Tune and clean HVAC: Perform seasonal cleanups on air conditioners, boilers and furnaces, and regularly clean cooling coils and drain pans. Get rooftop or outdoor condenser coils cleaned and maintain an appropriate filter changing schedule.
c. Check (or ask your HVAC contractor to check) your outside air dampers or economizers to verify proper ventilation. Make sure economizer controls function properly. Make sure automatic dampers close during unoccupied periods.
d. Restore automatic control: When troubleshooting a system, take time to figure out and repair the automatic controls. Today's quick fix is tomorrow's bad idea.
e. Reasonable set points: Try 68°F in the heating season and 78°F in the cooling season.
f. Schedule HVAC equipment and lighting: (weekdays, weekends, holidays, off-season). Make sure equipment runs only when it is needed and the buildings are occupied. When buildings are vacant (i.e. dormitories during the day with students in class), make sure all the lights in the building are off.
g. Seasonal (resets, schedules, and shutoffs): As the seasons change, adjust set points and schedules to match the system's response to the weather.
h. Lighting: Invest in an inexpensive light level meter to measure the foot-candles in spaces to determine whether or not they are over lit and lamps can be safely removed. Where four-lamp fixtures are in use, two lamps can usually be removed from every fixture or every other fixture. After lamps are removed, disconnect ballasts. Contact the Energy team at PBDewberry for suggested light levels for individual space types. Cleaning fixtures regularly increases light levels.
i. Utilize power management features for all computers and monitors to shut them off when idle for more than 15 minutes.
Page: 3 Date: 06/04/2009
j. Have your vending machine suppliers turn off or remove light tubes from the advertising lighting in the machine. This will save about $50 per year per vending machine.
k. Save water with low flow sink aerators (0.5gpm) and low flow shower heads (1.5gpm - 2.0gpm). This will also reduce water heating energy consumption.
l. Set your water heater to 120°F. Verify by measuring at the tap. Never go below 115°F.
m. For water heaters installed in unconditioned spaces, add insulation blankets making sure that access covers, electric connection areas, and pressure relief valves are left uncovered.
n. Caulk and fill cracks around doors and windows to reduce costly air leaks.
o. When replacing broken glass, use high transmittance, low heat gain windows.
p. Make sure automatic door closers are functioning properly to avoid drafts.
3. Buy energy efficient, buy EnergyStar (www.energystar.gov).
a. Buy EnergyStar appliances and equipment.
b. Replace burned out lightbulbs with EnergyStar labeled compact fluorescent lightbulbs (CFLs).
c. Replace broken thermostats with EnergyStar labeled programmable products.
d. Replace broken exit signs with EnergyStar LED exit signs.
Environmental Management Report
Page: 1 Date: 06/04/2009
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
Yes Building 4 (Vocational Trades/Warehouse)
Oil-based paint (1,000 gals), organic solvent (300 gals), propane Yes
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazadous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance :
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Non-PCB Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Browning Ferris Industries, Inc.
Yes Lead/acid batteries (2-4 per year)
Conditionally Exempt Small Quantity Generator N/A Commercial Hazardous Waste Disposal Service
United Environmental Services, Waimanalo, HI
No No
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
No N/A
No Survey Required due to Age of Buildings None N/A
N/A No
No Yes
ID Fuel Type Capacity Location Overfill Secondary Containment
2 Petroleum - Waste Oil 50 Near Building 4 No Yes
Tank Status Active
Tank Status
Radon
Date: Jun. 04, 2009Center : Hawaii (00903) Page: 1 of 1
0001 - GATEHOUSE
0002 - ADMINISTRATION
0002A - MEDICAL/DENTAL
0003 - EDUCATION CENTER
0004 - HARD VOC/WARE HOUSE/OACTS
0005 - DINING/CULINARY ARTS
0006 - RECREATION/GROUP LIFE
0007 - MALE AND FEMALE DORM
0008 - CHILD DEVELOPMENT CENTER
Bldg Name Test Date
No
No
No
No
No
No
No
No
No
Radon Testing
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description
Page: 1 Date: 06/04/2009
ACCESSIBILITY
Yes
NoNoNoNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Drain System Soil Erosion Soil Erosion Location
No N/ASurface Run-off
Paving Type for Roads & Parking Paving Type for Sidewalks
Asphalt Concrete
Comments:
Structures Fencing Outdoor Recreation
Four Pavilions, Three Storage Containers, Four Storage Structures
Chain Link, CMU Amphitheater, Basketball, Volleyball
The chain link fence is located at the north and portions of the east and west property lines. CMU fence is located at portions of the east and west property lines.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water
Treatment Type Storage Type Storage Capacity Maintenance Responsibility
Utility
NoMasterCity of Honolulu Board of Water SPublic Water Authority
None 0None
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity Pressure Source # of Fire Pumps
Yes 0 0None Municipal
The nearest fire department is the Waimanalo Fire Station. The response time is 3 to 5 minutes.
Sewage Treatment Sewer Line Owner
N/APublicly Owned Treatment Works MunicipalityMunicipal
Maintenance ResponsibilityCapacity(Gallons)
Number of Deficiencies = 1
Accessible Parking: Accessible Slope:
Yes
Curb Cuts:
Yes
Ramps:
YesYes
Site Accessible Route:
HISTORIC PRESERVATION
STORM WATER SYSTEM Number of Deficiencies = 2
Number of Deficiencies = 1SITE FEATURES
UTILITY
3. Sanitary Sewer System/ Sewage Treatment Plant
2. Fire Protection
Page: 2 Date: 06/04/2009
Propane
None
Comments:
Electric Company
PCB Transformer Mounting
Transformer Ownership
Systems Ownership
Maintenance Responsibility
Hawaiian Electric Company
The underground service is brought from a utility pole on Hihimanu Street southeast of the center to a 750 kVA utility-owned, pad-mounted transformer located outside Building 6. The transformer energizes a 1,600A, 480/277V, 3-phase, 4 wire three-section (meter section, main switch section and distribution section) switchboard located in the electrical room on the north side of Building 6. With the exception of Gatehouse Building 1 which is sub fed from Administration Building 2, all buildings have step-down transformers for additional 120/208V 3-phase, 4 wire system. In addition to the primary meter at the center's service switchboard, a secondary electronic meter is installed at each of the individual building service entrance location. A 50 kVA propane fueled generator provides backup power for kitchen equipment via a 100A automatic transfer switch located in the loading dock of Dining/Culinary Arts Building 5. The generator and propane gas tank are located outside northwest of the building. The site lighting consists of building-mounted exterior lights, pole-mounted lights, and sport lights at the basketball court. The sport lights are locally controlled and the pole and building-mounted fixtures are controlled by photocells and timeclock. The center owns and maintains the site lighting system.
Pad Center Center CenterNo
Comments:
Telephone Company On-site Line Owner
The telephone service is brought to the center by Hawaiian Telephone Company and terminates in the electrical room in Building 6. From this location Job Corps Data Center provides and maintains the digital voice over IP (VoIP) and data network for the entire center. The cable TV (CATV) service, security and fire alarm system are also routed through this location. The security system, monitored by the local security company Diebold, consists of door alarms, motion detectors and keypads installed in most buildings. The building fire alarm systems are connected to the main fire alarm control/annunciator panel located in the gate house.
Hawaiian Telephone - Verizon
Maint. Responsibility
Center Center
Security
Motion Detectors, Door Alarms, Keypads
01/01/1995
01/01/1995
Center
Center
Active
Active
Aboveground
Aboveground
Near Building 5
Near Building 4
Propane is provided to the dormitory for domestic hot water and to the dining hall for domestic hot water and cooking appliances.
Yes
Yes
Propane
Petroleum - Waste Oil
STORAGE TANK
Comments:
TypeStatus Location Owner Fuel Type Capacity Install Date
12.4/7.2 kV, 3-Phase, 4 Wire
480/277V, 3-Phase,4 W and 120/208V, 3-Ph, 4 WUnderground
Overhead & UndergroundPrimary Service
Secondary Service
Distribution Characteristics
ID
Reg.
4. Gas
5. Central Plant
6. Electric
7. Communication
Other
Waste Oil
Purpose
Page: 3 Date: 06/04/2009
Earthquake Risk
Medium High LowLow LowUniform Medium
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
GENERAL SITE CONDITION
Rating X Good Fair Poor
NATURAL HAZARDS
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
D Descriptions
Building Descriptions and Utilities Hawaii Job Corps Center
BUILDING 1 - GATEHOUSE
Building Descriptions
Page: 1 of 41
Building: 0001 - GATEHOUSE
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Business 280 234 1 Owned 1995 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
No
No
Yes
N/A
N/A
N/A
Yes
Yes
N/A
N/A
N/A
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 1995 7 Hip Entire Building
3. Roof
Entire Building
Area Served
Page: 2 of 41
Building: 0001 - GATEHOUSE
INTERIOR FINISH
Vinyl Tile
Drywall
Wood Unit - Wood Frame
Natural Entire Building
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Stairs
Comments: Concrete stairs lead to the entry.
Casement - Wood Frame; Single Glazing;
Split Direct Expansion (Air
Source)
Split Ductless None Electric Natural None Entire Building
Gypsum Board
Exhaust Ventilation
The gatehouse is cooled by a Mitsubishi model MS15TN split ductless system.Comments:
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Ceilings
3. Air Conditioning
Page: 3 of 41
Building: 0001 - GATEHOUSE
None None None
None
None
None None ABC Type Fire Extinguisher
Comments: This building is subfed from Building 2. Electrical usage in this building is reflected in Building 2 meter.
None None None None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Comments: The recorded footcandle level includes natural light contribution.
High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells. Building-mounted fixtures are both incandescent and compact fluorescent lights.
LIGHTING
T8 - Fluorescent55Offices 50
Area Recommended Recorded Light Type
None None
Main Branch Panel 120/208V, 3-Phase, 4 Wire Branch Panel Only Receptacles, Switches
Sprinkler System Stand Pipe System Fire Suppression
Emergency Exit
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
Page: 4 of 41
Building: 0001 - GATEHOUSE
FIRE ALARM
Comments: The central fire alarm control/annunciator panel is located in this building. It is a Simplex model 4602.
Control/Annunciator Panel
Connected to Main System None None None
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas N/A N/AZone
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
BUILDING 2 - ADMINISTRATION
Page: 5 of 41
Building: 0002 - ADMINISTRATION
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof None Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Business 5,434 4,200 1 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Asphalt Shingles Gutters and Downspouts 1995 7 Hip Entire Building
3. Roof
Page: 6 of 41
Building: 0002 - ADMINISTRATION
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Wall Covering Wood Paneling
Metal Unit - Metal Frame Wood Unit - Metal Frame
Wood Unit - Wood Frame
Mechanical
Mechanical
Restroom
Janitor's Closet
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Ramp Concrete Stairs
Comments: Concrete stairs and concrete ramp lead to the entry.
Fixed - Aluminum Frame; Single Glazing; Hopper - Aluminum Frame; Single Glazing;
Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Wood Truss Gypsum Board
Exhaust Ventilation
Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Ventilation2.
Page: 7 of 41
Building: 0002 - ADMINISTRATION
Domestic hot water is provided by a State 66-gallon water heater.Comments:
PVC None None
Electric Water Cooler Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Comments: Service is brought from a 225A, 480/277V, 3-phase, 4 wire panel and a 75 kVA transformer located in Medical/Dental Building 2A electrical room. Service terminates in a 225A MCB panel. A meter is installed near the panels. The 75 kVA transformer provides 208/120V, 3-phase, 4 wire system. Gatehouse Building 1 is sub-fed from a 150A MCB, 120/208V, 3 -phase, 4 wire panel in this building.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Split Ductless
Single Duct
Refrigerant
None
Electric
Electric
Natural
Mechanical
None
None
Offices
Offices
Main Distribution Panel 277/480V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Two Mitsubishi model M509TW and three Carrier 9,700 BTUH split ductless systems provide air conditioning to offices on the northwest side of the building.
Air conditioning for offices on the southeast of the building is provided by a Trane model TCH150D400BB packaged unit.
Comments:
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Page: 8 of 41
Building: 0002 - ADMINISTRATION
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Simplex model 4001 located in the waiting area. It is connected to the central fire alarm control/annunciator panel in Gatehouse Building 1.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Remote Annunciator Smoke Detector Visual Alarm
Connected to Main System Motion Detector None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: Some exit signs in the building are LED.
Compact Fluorescent High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
Offices
Conference Rooms
Reception
Lounges
Corridors & Stairs
Toilets
Storage Rooms
Equipment Rooms (Elec/Mech)
Area Recommended Recorded Light Type
Selected Lighting w/ Battery Tritium Gas
Emergency Exit
Number of Deficiencies = 1
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
Electric Water Gas No N/AZone
Page: 9 of 41
Building: 0002 - ADMINISTRATION
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
Structure: Good Exterior: Good Interior: Good Mechanical: Fair Electrical: Good
BUILDING 2A - MEDICAL/DENTAL
Page: 10 of 41
Building: 0002A - MEDICAL/DENTAL
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Business 2,516 1,904 1 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Asphalt Shingles Gutters and Downspouts 1995 7 Hip Entire Building
3. Roof
Page: 11 of 41
Building: 0002A - MEDICAL/DENTAL
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall Wall Covering Wood Paneling
Metal Unit - Metal Frame Wood Unit - Metal Frame
Wood Unit - Wood Frame
Mechanical Toilet/Shower
Ventilation Area Served
VERTICAL CIRCULATION
None
Fixed - Aluminum Frame; Single Glazing; Hopper - Aluminum Frame; Single Glazing;
Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Page: 12 of 41
Building: 0002A - MEDICAL/DENTAL
Domestic hot water is provided by a Ruud 65-gallon water heater.Comments:
PVC None None
Electric Water Cooler Hose Bibb Lavatory Shower/Bathtub Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Comments: Service is brought to Medical/Dental Building 2A from a 225A breaker in the 1,600A, 480/277V, 3-phase, 4 wire switchboard located in Recreation/Group Life Building 6. Service terminates in a 255A, 480/277V, 3-phase, 4 wire main distribution panel (MDP) located in Building 2A electrical room. A 75 kVA transformer provides 120/208V, 3-phase, 4 wire system in the building. A meter is installed near the MDP. The MDP and the transformer also serve the nearby Administration Building 2.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Single Duct Refrigerant Electronic Mechanical None Entire Building
Main Distribution Panel 277/480V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Air conditioning is provided by a Carrier model 40RR-012-550 air handler with evaporator coils paired with a Carrier model 38ARS-012---611 air-cooled condensing unit.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Page: 13 of 41
Building: 0002A - MEDICAL/DENTAL
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Simplex model 4001, located in the waiting area and connected to the central fire alarm control/annunciator panel in Gatehouse Building 1.
Comments: A security keypad is installed at the administration office entrance/exit door.
Audible Alarm Control/Annunciator Panel Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System Motion Detector None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Compact Fluorescent High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Medical/Dental
Reception
Wards (Patient)
Corridors & Stairs
Toilets
Storage Rooms
Equipment Rooms (Elec/Mech)
Area Recommended Recorded Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No N/AZone
BUILDING 3 - EDUCATION CENTER
Page: 14 of 41
Building: 0003 - EDUCATION CENTER
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Business 10,760 9,465 1 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 1995 7 Hip Entire Building
3. Roof
Page: 15 of 41
Building: 0003 - EDUCATION CENTER
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall
Wood Unit - Metal Frame
Mechanical
Mechanical
Mechanical
Restroom
Janitor's Closet
Equipment Room
Ventilation Area Served
VERTICAL CIRCULATION
Concrete Ramp Concrete Stairs
Comments: Concrete stairs and concrete ramp lead to the entry.
Hopper - Aluminum Frame; Single Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Ventilation2. Number of Deficiencies = 1
Page: 16 of 41
Building: 0003 - EDUCATION CENTER
Domestic hot water is provided by a Rheem model RMEMVR50 water heater.Comments:
PVC None None
Electric Water Cooler Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Comments: Service is brought to Building 3 from a 250A breaker in the 1,600A, 480/277V, 3-phase, 4 wire switchboard located in Recreation/Group Life Building 6. Service terminates in a 300A, 480/277V, 3-phase, 4 wire main distribution panel (MDP) located in Building 3 electrical room. A 75 kVA transformer provides 120/208V, 3-phase, 4 wire system in the building. A meter is installed near the MDP.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Portable Unit
Refrigerant
None
Electric
Electric
Mechanical
Natural
None
None
Entire Building
Electronic Equipment
Room
Main Distribution Panel 277/480V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Air conditioning is provided by a Carrier model 39NSX26-N air handler with coils matched to a Carrier model 38AK-044-600 condensing unit.
The portable units are Freecom model M2000 portable air conditioners.
Comments:
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 1
Page: 17 of 41
Building: 0003 - EDUCATION CENTER
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Simplex model 4001, located behind the reception desk and connected to the central fire alarm control/annunciator panel in Gatehouse Building 1.
Comments: In addition to TV and VCR, the classrooms are provided with computer work stations. A security keypad is installed at each classroom entrance/exit door.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Remote Annunciator Visual Alarm
Connected to Main System Motion Detector None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Compact Fluorescent High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
LIGHTING
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Classrooms
Offices
Conference Rooms
Storage Rooms
Toilets
Mail Room
Equipment Rooms (Elec/Mech)
Area Recommended Recorded Light Type
Selected Lighting w/ Battery Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No N/AYes
BUILDING 4 - HARD VOC/WARE HOUSE/OACTS
Page: 18 of 41
Building: 0004 - HARD VOC/WARE HOUSE/OACTS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
Metal Siding
Wall Roof Batt Sprayed
Metal Rollup - Steel Frame Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Factory/Industrial 15,485 14,070 2 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Metal Gutters and Downspouts 1995 27 Gable Entire Building
3. Roof
Page: 19 of 41
Building: 0004 - HARD VOC/WARE HOUSE/OACTS
INTERIOR FINISH
Carpet Ceramic Tile Concrete Metal Plywood Vinyl Tile
CMU Ceramic Tile Drywall Plaster Wood Paneling
Metal Unit - Metal Frame Wood Unit - Metal Frame
Wood Unit - Wood Frame
VERTICAL CIRCULATION
Metal Stairs Wood Stairs
Comments: Wood stairs and metal stairs lead to the storage mezzanine.
Fixed - Aluminum Frame; Louvers Glazing; Fixed - Wood Frame; Single Glazing;
Hopper - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Windows6. Number of Deficiencies = 1
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Page: 20 of 41
Building: 0004 - HARD VOC/WARE HOUSE/OACTS
Mechanical
Natural
Mechanical
Dust Collection
Restroom
Shop Area
Paint Booth
Shop Area
Comments: The facility maintenance vocation shop is equipped with a dust collector.
Ventilation Area Served
Packaged Direct
Expansion (Air Source)
Split Direct Expansion (Air
Source)
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Portable Unit
Split Ductless
Single Duct
Window Unit
None
Refrigerant
Refrigerant
None
Electric
Electric
Electric
Electric
Natural
Natural
Natural
Natural
None
None
None
None
Classrooms and Offices
Offices
Offices
Offices
Exhaust Ventilation
Portable air conditioners include an 18,000 BTUH army surplus unit in the automotive vocation classroom and Freecom model M2000 portable units in some offices.
The TABE testing room is cooled by a Mitsubishi PUY-A30NHA split ductless system.
A Rheem model RAKA-048JAZ system cools the Work Based Learning offices.
One vocation office uses a window unit rejecting heat to the shop area.
Comments:
Comments:
Comments:
Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Page: 21 of 41
Building: 0004 - HARD VOC/WARE HOUSE/OACTS
PVC None None
Electric Water Cooler Emergency Eye Wash Hose Bibb Lavatory Sink Water Closet (Flush Valve)
None
None None ABC Type Fire Extinguisher
Comments: The paint booth is provided with an ABC automatic fire extinguishing system.
Comments: Service is brought to Building 4 from a 300A breaker in the 1,600A, 480/277V, 3-phase, 4 wire switchboard located in Recreation/Group Life Building 6. Service terminates in a 300A, 480/277V, 3-phase, 4 wire main distribution panel (MDP) located in the warehouse in Building 4. A 150 kVA transformer provides 120/208V, 3-phase, 4 wire system in the building. A meter is installed near the
MDP.
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Comments: Exterior lighting is provided by surrounding area pole-mounted light fixtures which are controlled by time clock and photocells.
LIGHTING
Main Distribution Panel 277/480V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
Exterior Lighting1.
Page: 22 of 41
Building: 0004 - HARD VOC/WARE HOUSE/OACTS
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Simplex model 4005, located in the warehouse office and connected to the central fire alarm control/annunciator panel in Gatehouse Building 1. A Simplex remote annunciator panel is installed near the center maintenance roll up door.
Comments: A security keypad is installed at each of the shop entrance/exit door.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Remote Annunciator Visual Alarm
Connected to Main System Motion Detector None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. The landscaping shop has eight 2x4 skylights.
Compact Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Classrooms
Classrooms
Offices
Locker Room
Storage/Warehouse-Active
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Recorded Light Type
Selected Lighting w/ Battery Battery Backup
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No N/AYes
BUILDING 5 - DINING/CULINARY ARTS
Page: 23 of 41
Building: 0005 - DINING/CULINARY ARTS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Assembly 9,260 8,260 1 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Built-up Roofing
Asphalt Shingles
Interior Roof Drains
Surface Run-off
Flat
Hip
Kitchen
Entire Building
Number of Deficiencies = 13. Roof
Page: 24 of 41
Building: 0005 - DINING/CULINARY ARTS
INTERIOR FINISH
Ceramic Tile Concrete Quarry Tile Vinyl Tile
Ceramic Tile Drywall Plastic Laminate Stainless Steel
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Ramp Concrete Stairs
Comments: Concrete stairs and concrete ramp lead to the entry.
Hopper - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
HVAC
Heat1.
None None None None Natural None None
Page: 25 of 41
Building: 0005 - DINING/CULINARY ARTS
Mechanical
Mechanical
Mechanical
Mechanical
Restroom
Kitchen Hood
Dishwashing Hood
Dining Room
Comments: There are solar powered exhaust fans in the dining room.
Ventilation Area Served
Packaged Direct
Expansion (Air Source)
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Portable Unit
Split Ductless
Window Unit
None
None
Refrigerant
Electric
Electric
Electric
Natural
Natural
Natural
None
None
None
Offices
Dining Hall
Offices
Exhaust Ventilation
The main kitchen office is cooled by a Freecom model M2000 unit.
One Mitsubishi split ductless unit serves the culinary arts dining area and one serves the main kitchen dry food storage area.
The culinary arts instructor's office is cooled by a window unit.
Comments:
Comments:
Comments:
Ventilation2.
System Type
Number of Deficiencies = 1
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Area Served
Page: 26 of 41
Building: 0005 - DINING/CULINARY ARTS
Three State model SBF100 199 PET1 commercial propane-fired water heaters serve the main kitchen and culinary arts.
Comments:
Comments:
PVC Outdoor None
There are two grease traps. One for the main kitchen and one for culinary arts.
Electric Water Cooler Emergency Eye Wash Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
Gas (Propane)
None None ABC Type Fire Extinguisher, K Type Fire Extinguisher, Wet Chemical
Comments: All hoods are protected by UL 300 compliant wet chemical fire suppression systems.
Comments: Service is brought to Building 5 from a 500A breaker in the 1,600A, 480/277V, 3-phase, 4 wire switchboard located in Recreation/Group Life Building 6. Service terminates in a 500A, 480/277V, 3-phase, 4 wire main distribution panel (MDP) located in the loading dock of Building 5. Two transformers, a 225 kVA and a 30 kVA, provide 120/208V, 3-phase, 4 wire system in the building. A meter is installed near the MDP. Arrangement for backup power for kitchen equipment consists of a 50 kW propane fueled generator, a 100A, 480/277V automatic transfer switch, a 100A, 480/277V, 3-phase, 4 wire panel, a 30 kVA transformer and a 100A, 120/208V, 3-phase, 4 wire panel.
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
LIGHTING
Main Circuit Breaker 277/480V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Exterior Lighting1.
Page: 27 of 41
Building: 0005 - DINING/CULINARY ARTS
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Simplex model 4001, located in the mechanical room and connected to the central fire alarm control/annunciator panel in Gatehouse Building 1.
Comments: A security keypad is installed at the entrance to the kitchen and honor dining room.
Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Remote Annunciator Smoke Detector Visual Alarm
Connected to Main System Motion Detector None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Lighting in the dining room is a combination of decorative pendant-mounted compact fluorescent fixtures, paddle fans with incandescent lights and fluorescent cove lighting. There is a large skylight at the center of the dining room.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Classrooms
Food Preparation
Dining/Lunch Rooms
Locker Room
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Recorded Light Type
Battery Backup Tritium Gas
Emergency Exit
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2. Number of Deficiencies = 1
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoYes
Structure: Good Exterior: Good Interior: Good Mechanical: Fair Electrical: Good
BUILDING 6 - RECREATION/GROUP LIFE
Page: 28 of 41
Building: 0006 - RECREATION/GROUP LIFE
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Stucco Wood Siding
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
Assembly 11,100 8,845 1 Owned 1995 Unevaluated
Comments: Strobes are not provided in public restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Type Area Served
Asphalt Shingles Gutters and Downspouts 1995 7 Hip Entire Building
3. Roof
Page: 29 of 41
Building: 0006 - RECREATION/GROUP LIFE
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
Ceramic Tile Drywall
Metal Unit -…