J-9_Facility_Survey_2012_Vol_2_Part_2.pdf

PDF 14 MB Posted

Attached to
Operation of the Gary Job Corps Center with OA/CTS
Solicitation number
DOL-ETA-16-R-00059
Issued by

About this file

Facility Survey 2012 Vol 2 Part 2

View the file

Other files

File Type Posted
Sol_DOL-ETA-16-R-00059_Amd_000006.pdf PDF
Sol_DOL-ETA-16-R-00059_Amd_000005.pdf PDF
DOL-ETA-16-R-00059_Amendment_5_Questions_and_Answers.pdf PDF
DOL-ETA-16-R-00059_Amendment_4_Q_and_As.pdf PDF
Sol_DOL-ETA-16-R-00059_Amd_000004.pdf PDF
DOL-ETA-16-R-00059_Amendment_4_Revised_Sections_L_and_M.pdf PDF
DOL-ETA-16-R-00059_Amendment_3.pdf PDF
DOL-ETA-16-R-00059_Amendment_3_Q_and_As.pdf PDF
Sol_DOL-ETA-16-R-00059_Amd_000003.pdf PDF
Sol_DOL-ETA-16-R-00059_Amd_000002.pdf PDF
Vehicle_Lease_Report_Gary_JCC.pdf PDF
Vehicle_Fuel_Log_Gary_JCC.pdf PDF
DOL-ETA-16-R-00059_Amendment_2_Questions_and_Answers.pdf PDF
Sol_DOL-ETA-16-R-00059_Amd_000001.pdf PDF
J-7_Past_Performance_Questionnaire.pdf PDF
J-6_Subcontracting_Plan_Summary_Sheet.pdf PDF
J-2_Statement_of_Financial_Capability_ETA_8554.pdf PDF
J-15_Dallas_Region_Career_Pathway_Plan.pdf PDF
J-9_Facility_Survey_2014_Vol_2_Part_1.pdf PDF
J-8_Standard_Form_1413_Statement_and_Acknowledgement.pdf PDF
J-4_STAFFING_CHART.pdf PDF
J-3_Financial_Display_ETA_2110.pdf PDF
J-17_DB_Wage_Determinations_Gary.pdf PDF
Sol_DOL-ETA-16-R-00059.pdf PDF
J-5_CTST.pdf PDF
J-9_Facility_Survey_2012_Vol_2_Part_3.pdf PDF
J-10_Gary_Property_Summary_Rpt.pdf PDF
J-9_Facility_Survey_2014_Vol_1.pdf PDF
J-10_Gary_Master_Property_Rpt.pdf PDF
J-13_National_Staff_Compensation_Report_GARY.pdf PDF
J-11_Gary_Inventory_Estimate.pdf PDF
J-1_Cost_Detail_Template.pdf PDF
J-12_Utilities_and_Energy_Usage_Information.pdf PDF
J-18_SCA_Wage_Determinations_01_12_2016.pdf PDF
PRE-SOLICITATION_NOTICE_Gary_JCC.docx DOCX document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GaryGary

Job Corps Center San Marcos, TX

Facility Planning ReportFacility Planning Report Volume II (2 of 3)

Supporting Data Buildings: 07-171 thru 11-353

Structures: 00-100 thru 11-350A Typical Staff Housing and Carport

FinalFinal February 2012

Department of Labor/ Office of Job Corps

22Gary Job Corps Center

GaryGary

Job Corps Center San Marcos, TX

Facility Planning Reporty g p Volume II (2 of 3)

Supporting Data Buildings: 07-171 thru 11-353

Structures: 00-100 thru 11-350A Typical Staff Housing and Carport

Final February 2012

Building 7-300 Dining Hall

33 Gary Job Corps Center

CONTENTS

GARY JOB CORPS CENTER

FACILITY PLANNING REPORT

VOLUME I - Planning Strategy

• Existing Site Plan

• Center Statistics

INTRODUCTION

• Purpose

• Report Contents

EXECUTIVE SUMMARY

A. EXISTING CONDITIONS

• Background

• General Site Conditions

• General Building Conditions

• Preventive Maintenance

• Ownership

• Facility Assessment by Function

• Energy

• Environmental Issues

• Sustainability

• Accessibility Standards

• Completed and Current Projects Since the Last Survey

• Health and Life Safety Issues

• Summary of Defi ciencies

B. RECOMMENDATIONS

• Status of the Previous (PY08) Plan

• Signifi cant Issues

• PY 11 Plan Overview

• Summary of Proposed Projects

• Regional Projects

• Proposed Phase I Site Plan

• Proposed Phase II Site Plan

• Proposed Futre Site Plan

• Implementation Plan

• Summary of National Projects

• Project Data Sheets

C. PLANNING ANALYSIS

• Purpose

• Planning Objectives and Assumptions

• Space Utilization Analysis

• Federal Real Property Asset Management

• Mission Dependency Site Plan

• Defi ciency Analysis

• Facility Condition Summary Report

• Building Condition by Function

• Building Condition Site Plan

VOLUME II - Supporting Data

• VICINITY MAP

• LOCATION MAP

• EXISTING SITE PLAN

D. DESCRIPTIONS

• Building and Structures

• Space Utilization By Function

• NSF by Building

• Energy Management Report

• Environmental Management

Asbestos Report Radon Report

• Site Descriptions

• Building Descriptions

• Building Descriptions: 00-301 thru 07-165

• Existing Site Plan

• Building Descriptions: 07-171 thru 11-353

• Structures: 00-100 thru 11-350A

• Typical Staff Housing and Carport

• Existing Site Plan

E. DEFICIENCIES

F. CORRESPONDENCE AND REPORTS

• Center Review Brief

• Survey Brief

• RA and Student Facility Feedback Questionnaire

• Life Safety Defi ciencies Transmittal and List

• O & M Defi ciency List

• Active Warranty Report

• FRPC Performance Measures Matrix

• Existing Site Plan (11x17)

• Proposed Phase I Site Plan (11x17)

• Proposed Phase II Site Plan (11x17)

• Mission Dependency Site Plan (11x17)

• Building Condition Site Plan (11x17)

• Future Center Reconfi guration Site Plan (11x17)

G ary Job C orps C enter

55 Gary Job Corps Center

D Descriptions

Building Descriptions and Utilities Gary

BUILDING 07 171 HEALTH OCCUPATIONS/VACANT/CNABUILDING 07-171 - HEALTH OCCUPATIONS/VACANT/CNA

Building Descriptions Date: Feb. 07, 2012Center : Gary (00606) Page: 255 of 499

Building: 07-171 - HEALTH OCCUPATIONS/VACANT/CNA

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Wood Wood

Ceramic Tile Stucco Wood Siding

Wall Roof None None

Metal Unit - Metal Frame Wood Unit - Wood Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 4,968 3,811 1 Owned 1942 Unevaluated

Comments: There are no visual alarms in toilet rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

No

No

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material

Repairs of tabs are complete and the roofing should provide protection for another 6 years.

Drainage Year Life

Remaining Type Area Served

Asphalt Shingles Surface Run-off 1990 6 Gable Entire Building

Comments:

3. Roof

Entire Building

Area Served

Page: 256 of 499

Building: 07-171 - HEALTH OCCUPATIONS/VACANT/CNA

INTERIOR FINISH

Ceramic Tile Resilient Vinyl Tile

Ceramic Tile Drywall Wood Paneling

Comments: One interior wall is lead lined that was used to protect students and staff from the x-ray machine.

Wood Unit - Wood Frame

Mechanical Restroom

Ventilation Area Served

VERTICAL CIRCULATION

None

Casement - Aluminum Frame; Single Glazing; Single Hung - Aluminum Frame; Double Glazing;

Acoustical Tile Gypsum

Exhaust Ventilation

Windows6.

Floors1. Asbestos: Yes Number of Deficiencies = 1

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

There are two furnaces (Carrier #58PAV090, 71 MBH output) serving this building.Comments:

HVAC

Heat1.

Gas-Fired Furnace

Single Duct None Electric Natural None Classrooms

Ventilation2. Number of Deficiencies = 1

Ceilings

Page: 257 of 499

Building: 07-171 - HEALTH OCCUPATIONS/VACANT/CNA

The water heater (State #PV4020AT8F, 4.5 kW, 40 gallon) is electric.Comments:

Cast Iron, PVC None None

Electric Water Cooler Hose Bibb Lavatory Multi-Compartment Sink Service Sink Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Comments: Overhead service is provided to a 400A disconnect fused at 400A, which in turn serves a 400A main-lug-only panelboard (Square D, NQO-424-4).

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Split Heat Pump (Air

Source)

Portable Unit Refrigerant Electric Natural None Classrooms

None

Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

There are two condensing units (Carrier #38AK008, 7-1/2 tons) serving this building.Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2. Number of Deficiencies = 1

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 4

Exterior Lighting1.

3. Air Conditioning

LIGHTING

Page: 258 of 499

Building: 07-171 - HEALTH OCCUPATIONS/VACANT/CNA

FIRE ALARM

Comments: The fire alarm panel is an ESL 1500.

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Comments: Photoluminescent exit signs are also utilized.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Compact Fluorescent

Offices

Classrooms

Storage Rooms

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

The vinyl floor is dilapidated; rain penetrates through door edges;

interior finishes in vacant areas are in poor condition.

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 2

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Fair Interior: Fair Mechanical: Good Electrical: Good

BUILDING 07 172 VACANTBUILDING 07-172 - VACANT

Page: 259 of 499

Building: 07-172 - VACANT

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Loadbearing Masonry Wood

CMU Masonry Wood Siding

Wall Roof None None

Metal Overhead - Metal Frame Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 2,046 1,141 1 Owned 1995 Unevaluated

Comments: This building was formerly an automotive paint booth.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

No

Yes

No

No

N/A

N/A

N/A

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Asphalt Shingles

Asphalt Shingles

Surface Run-off

Surface Run-off

Gable

Gable

Entire Building

Storage Addition

3. Roof

Page: 260 of 499

Building: 07-172 - VACANT

INTERIOR FINISH

Concrete

CMU

Metal Unit - Metal Frame

Natural

Mechanical

Entire Building

Paint Booth

Comments:

Comments:

The paint booths are operable but no longer used.

When a paint booth is operating the building is ventilated. Otherwise, it is natural.

Ventilation Area Served

VERTICAL CIRCULATION

None

None

Exposed structure

Exhaust Ventilation

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The paint booths receive heated makeup air.Comments:

HVAC

Heat1.

Gas-Fired Furnace

Makeup Air Unit

None Electric Mechanical None Shop Area

Page: 261 of 499

Building: 07-172 - VACANT

Cast Iron, PVC None None

Emergency Eye Wash Hose Bibb Service Sink

Gas (Natural)

None None ABC Type Fire Extinguisher, Dry Chemical

Comments: Underground service for this building is provided from pole-mounted center-owned transformer bank, located at the east side of the building, to two exterior-mounted adjacent disconnects, each rated and fused at 200A.

None Copper None None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

None None None None Natural None Entire Building

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

Main Disconnect Switches 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1. Number of Deficiencies = 1

Page: 262 of 499

Building: 07-172 - VACANT

FIRE ALARM

Comments: The fire alarm panel is a Faraday Firewatch 2.

Audible Alarm Control Panel Heat Detector Manual Pull Station Visual Alarm

None None None None

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Comments: Three tritium gas exit signs are also utilized. These expired in 1994.

T8 - Fluorescent

T12 - Fluorescent

T8 - Fluorescent

Classrooms

Storage Rooms

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 2

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good

BUILDING 07 173 HEALTH OCCUPATIONSBUILDING 07-173 - HEALTH OCCUPATIONS

Page: 263 of 499

Building: 07-173 - HEALTH OCCUPATIONS

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Wood Wood

Ceramic tile Stucco T111 Siding

Wall Roof None Batt

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 4,924 3,121 1 Owned 1942 Unevaluated

Comments: There are ramps into the toilet rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

Yes

Yes

Yes

Yes

Yes

Yes

N/A

N/A

Yes

No

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material

The roofing has been repaired and it should provide protection for another 6 years.

Drainage Year Life

Remaining Type Area Served

Asphalt Shingles Surface Run-off 1990 6 Gable Entire Building

Comments:

3. Roof

Page: 264 of 499

Building: 07-173 - HEALTH OCCUPATIONS

INTERIOR FINISH

Ceramic Tile Concrete Vinyl Tile

Ceramic Tile Drywall

Metal Unit - Metal Frame Wood Unit - Metal Frame

Mechanical

Mechanical

Shop Area

Restroom

Ventilation Area Served

VERTICAL CIRCULATION

Ramp

Single Hung - Aluminum Frame; Single Glazing;

Acoustical Tile

Exhaust Ventilation

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The heat pump (Ruud #UPMA036JAZ, 36 MBH output) is roof-mounted.

The two units (Bryant, 3000 CFM) are mounted on the roof.

Comments:

Comments:

HVAC

Heat1.

Split Heat Pump (Air

Source)

Gas-Fired Packaged

Single Duct

Single Duct

Refrigerant

None

Electric

Electric

Natural

Natural

None

None

Classrooms and Offices

Entire Building

Page: 265 of 499

Building: 07-173 - HEALTH OCCUPATIONS

Cast Iron, PVC None None

Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Service Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None None

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Packaged Direct

Expansion (Air Source)

Single Duct

Single Duct

Refrigerant

None

Electric

Electric

Natural

Natural

None

None

Classrooms and Offices

Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The heat pump (Ruud #UPMA036JAZ, 3 tons) is roof-mounted.

The two units (Bryant, 7-1/2 ton) are mounted on the roof.

Comments:

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Number of Deficiencies = 1FIRE PROTECTION

Page: 266 of 499

Building: 07-173 - HEALTH OCCUPATIONS

Comments: Underground service is provided to a 225A exterior wall-mounted main circuit breaker located at the south exterior wall. A second overhead service is provided to a 100A main-lug-only loadcenter utilized for new HVAC equipment. A third overhead service is provided to a disconnect switch rated and fused at 100A.

The 100A loadcenter and 100A disconnect switch are located along the east exterior wall.

FIRE ALARM

Comments: The fire alarm panel is a Silent Knight IFP-50.

Comments: The building is connected to the center LAN system for data communications.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution. Occupancy sensors are incorporated for control.

Comments: Photoluminescent exit signs are also utilized.

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Classrooms

Corridors & Stairs

Toilets

Storage Rooms

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Circuit Breaker 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 3

Exterior Lighting1. Number of Deficiencies = 1

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 1

COMMUNICATION

Electric Water Gas No NoNo

Page: 267 of 499

Building: 07-173 - HEALTH OCCUPATIONS

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

The roof shingles have been damaged by high winds.

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good

BUILDING 07 174 HEALTH OCCUPATIONSBUILDING 07-174 - HEALTH OCCUPATIONS

Page: 268 of 499

Building: 07-174 - HEALTH OCCUPATIONS

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Wood Wood

Ceramic Tile Stucco T111 Siding

Wall Roof None None

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 5,095 3,966 1 Owned 1942 Unevaluated

Comments: The women's restroom is accessible and used by disabled persons of both genders.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

Yes

Yes

Yes

Yes

Yes

Yes

N/A

N/A

Yes

No

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material

The roofing appears to be in good condition, therefore it should provide protection for another 6 years.

Drainage Year Life

Remaining Type Area Served

Asphalt Shingles Surface Run-off 1990 6 Gable Entire Building

Comments:

3. Roof

Page: 269 of 499

Building: 07-174 - HEALTH OCCUPATIONS

INTERIOR FINISH

Ceramic Tile Concrete Vinyl Tile

Ceramic Tile Drywall Plywood

Wood Unit - Metal Frame

Mechanical Restroom

Ventilation Area Served

VERTICAL CIRCULATION

Ramp

Comments: The interior ramp is to the toilet room.

Single Hung - Aluminum Frame; Single Glazing; Sliding - Aluminum Frame; Single Glazing;

Acoustical Tile

Exhaust Ventilation

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The heat pump outdoor unit (Ruud #UPMA036JAZ, 36 MBH, built 4/1994) is located on the roof.

The HOT lab is served by a roof-mounted unit (Trane #TCD180, built 4/2008) with electric heat.

Comments:

Comments:

HVAC

Heat1.

Split Heat Pump (Air

Source)

Electric Resistance

Single Duct

Single Duct

Refrigerant

None

Electric

Electric

Natural

Mechanical

None

None

Classrooms and Offices

Classrooms and Offices

Ventilation2. Number of Deficiencies = 2

Page: 270 of 499

Building: 07-174 - HEALTH OCCUPATIONS

Cast Iron/PVC None None

Electric Water Cooler Hose Bibb Lavatory Service Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Packaged Direct

Expansion (Air Source)

Single Duct

Single Duct

Refrigerant

None

Electric

Electric

Natural

Mechanical

None

None

Classrooms and Offices

Classrooms and Offices

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The heat pump outdoor unit (Ruud #UPMA036JAZ, 3 ton, built 4/1994) is located on the roof.

The HOT lab is served by a roof-mounted unit (Trane #TCD180, 15 ton, built 4/2008).

Comments:

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

Page: 271 of 499

Building: 07-174 - HEALTH OCCUPATIONS

Comments: Underground service is provided to a 225A exterior wall-mounted main circuit breaker (MCB), which in turn serves a 250A panelboard (Siemens, S1C42Q225ATS). A second overhead service is provided to a 100A loadcenter with a 100A MCB utilized for new HVAC equipment.

FIRE ALARM

Comments: The fire alarm panel is a Silent Knight IFP-50.

Comments: The building is connected to the center LAN system for data communications.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution. Occupancy sensors are incorporated for control.

Comments: One battery backup exit sign is also utilized.

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Incandescent

Classrooms

Offices

Storage Rooms

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Photoluminescent

Main Circuit Breaker 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2. Number of Deficiencies = 1

Emergency /Exit Lighting3. Number of Deficiencies = 1

COMMUNICATION

Electric Water Gas No NoNo

Page: 272 of 499

Building: 07-174 - HEALTH OCCUPATIONS

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

The wood siding is deteriorated.

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

BUILDING 07 176 GARY DELUXE HOME ECONBUILDING 07-176 - GARY DELUXE HOME ECON

Page: 273 of 499

Building: 07-176 - GARY DELUXE HOME ECON

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Wood Wood

Ceramic Tile Stucco T111 Siding

Wall Roof None None

Comments: Double ceiling and air gap in between provide some insulation.

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 4,630 3,511 1 Owned 1942 Unevaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

N/A

N/A

Yes

Yes

N/A

N/A

Yes

No

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Material Drainage Year Life

Remaining Type Area Served

Asphalt Shingles

Metal

Surface Run-off 2004

Gable

Gable

Entire Building

Canopy

3. Roof

Page: 274 of 499

Building: 07-176 - GARY DELUXE HOME ECON

INTERIOR FINISH

Concrete Quarry Tile Vinyl Tile

Drywall Wood Paneling

Wood Unit - Wood Frame

VERTICAL CIRCULATION

None

Metal Unit - Metal Frame Wood Unit - Wood Frame

Single Hung - Wood Frame; Single Glazing;

Acoustical Tile Gypsum

Exterior Doors5.

Windows6.

Floors1.

Interior Walls2. Number of Deficiencies = 1

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

There are two units (Trane #YSC120A3RLA, 120 MBH output each) outside on steel stands and ducted into the building.

There are two electric wall heaters.

Comments:

Comments:

HVAC

Heat1.

Gas-Fired Packaged

Electric Resistance

Single Duct

Unit Heater

None

None

Electric

Electric

Natural

Natural

None

None

Entire Building

Offices

Page: 275 of 499

Building: 07-176 - GARY DELUXE HOME ECON

Mechanical

Mechanical

Restroom

Kitchen

Comments: There is a roof-mounted exhaust fan (Captive-Aire #NCA14FA, 1 HP, built 3/2005) that serves the 7'-0" x 6'-0" kitchen hood. It is interlocked with a roof-mounted makeup air unit.

The water heater (Rheem #G72250A, 72 gallon, 250 MBH input) was recently installed.Comments:

Cast Iron, PVC Outdoor None

Electric Water Cooler Hose Bibb Lavatory Multi-Compartment Sink Shower Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher, Dry Chemical

Ventilation Area Served

Copper, Galvanized Steel

Copper, PVC Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Packaged Direct

Expansion (Air Source)

Single Duct None Electric Natural None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Exhaust Ventilation

There are two units (Trane #YSC120A3RLA, 10 tons each) outside on steel stands and ducted into the building.

Comments:

Ventilation2.

System Type

Number of Deficiencies = 1

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Page: 276 of 499

Building: 07-176 - GARY DELUXE HOME ECON

Comments: Overhead service is provided to a trough with two 150A main circuit breakers, which in turn serve two 200A main-lug-only loadcenters (Square D, QOC-43OL).

FIRE ALARM

Comments: The fire alarm panel is an ESL 1500.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Visual Alarm

Connected to Main System Closed Circuit TV None Local Cable Company

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Comments: Photoluminescent exit sign is also utilized.

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Incandescent

Storage Rooms

Classrooms

Dining/Lunch Rooms

Food Preparation

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Circuit Breakers 120/208V, 3-Phase, 4 Wire Loadcenter Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

Location UL300 Compliance Status The hood is located in the kitchen. Compliant

UL300 COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION

Page: 277 of 499

Building: 07-176 - GARY DELUXE HOME ECON

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING 07 178 STORAGEBUILDING 07-178 - STORAGE

Page: 278 of 499

Building: 07-178 - STORAGE

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Metal Steel

Metal Siding

Wall Roof None None

Metal Overhead - Metal Frame Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Storage 3,510 3,371 1 Owned 1968 Unevaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

No

N/A

N/A

Yes

N/A

N/A

N/A

N/A

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Metal Surface Run-off 1997 26 Gable Entire Building

3. Roof

Page: 279 of 499

Building: 07-178 - STORAGE

INTERIOR FINISH

Concrete

Exposed Structure

None

Mechanical Entire Building

Comments: There is one small sidewall exhaust fan ventilating the building.

Ventilation Area Served

VERTICAL CIRCULATION

None

Single Hung - Aluminum Frame; Single Glazing;

None None None None Natural None Entire Building

Exposed Structure

Exhaust Ventilation

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

HVAC

Heat1.

Gas-Fired Unit Heater None Electric Natural None Entire Building

Ventilation2.

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Page: 280 of 499

Building: 07-178 - STORAGE

None None None

None

Gas (Natural)

None None None

Comments: Overhead service is provided to a 100A disconnect fused at 100A.

None None None None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Comments: As of the March 2011 Facility Survey, the lighting in this building was turned off at the loadcenter.

None

T8 - Fluorescent0Storage/Warehouse-Inactive 10

Area Recommended Level

Recorded Level Light Type

None Battery Backup

Main Disconnect Switch 120/208V, 1-Phase, 3 Wire Loadcenter Receptacles, Switches

Sprinkler System Stand Pipe System Fire Suppression

Emergency Exit

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2. Number of Deficiencies = 1

Emergency /Exit Lighting3.

Page: 281 of 499

Building: 07-178 - STORAGE

FIRE ALARM

None

Connected to Main System None None None

Telephone Security Public Address Television

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

The exterior is deteriorated.The interior finishes are in poor condition.

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas N/A NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Fair Interior: Fair Mechanical: Good Electrical: Good

This building has been recommended for demolition in the Long Range Development Plan.

DEMOLITION RECOMMENDATION

BUILDING 07 180 TCUBUILDING 07-180 - TCU

Page: 282 of 499

Building: 07-180 - TCU

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel Steel

CMU Masonry Metal Siding Wood Siding

Wall Roof Batt Batt

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 9,851 6,911 1 Owned 1989 Unevaluated

Comments: There are no visual alarms in toilet rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

Yes

Yes

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Metal Surface Run-off 1989 18 Gable Entire Building

3. Roof

Page: 283 of 499

Building: 07-180 - TCU

INTERIOR FINISH

Ceramic Tile Concrete Vinyl Tile

CMU Ceramic Tile Drywall

Metal Unit - Metal Frame Wood Unit - Metal Frame

VERTICAL CIRCULATION

None

Double Hung - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;

Acoustical Tile Exposed structure Gypsum Board

Number of Deficiencies = 1

Windows6.

Floors1.

Interior Walls2.

3. Number of Deficiencies = 1

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The corridor and restrooms are served by hot water unit heaters. The boiler (Cleaver-Brooks #WTW7031000, 1000 MBH input) is located in the mechanical room.

There are eight fan-coil units fitted with hot water coils.

The furnace was built by Carrier.

Comments:

Comments:

Comments:

HVAC

Heat1.

Gas-Fired Hot Water Boiler

Gas-Fired Hot Water Boiler

Gas-Fired Furnace

Unit Heater

Single Duct

Single Duct

Two-Pipe

Two-Pipe

None

Electric

Electric

Electric

Natural

Natural

Natural

None

None

None

Common Area

Classrooms and Offices

Offices

Page: 284 of 499

Building: 07-180 - TCU

Mechanical

Mechanical

Restroom

Corridor

The water heater was built by Rheem (#22V30F, 32 MBH input, 29 gallons, 2/2008).Comments:

Cast Iron/PVC None None

Electric Water Cooler Lavatory Mop Sink Urinal Wall Hydrant Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Ventilation Area Served

Copper Copper, Galvanized Steel

Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct Refrigerant Electric Natural None Classrooms and Offices

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Exhaust Ventilation

There are nine condensing units located at grade level around the building. (Four by Lennox #HS16511U8P, 4 tons, built 10/1991; three by Trane, two #TTB724B, 2 tons each built 1988 and a 2TTB0048A, 4 tons, built 6/2005; one by Carrier #24ABA336A310, 3 tons; and one by Nordyne #JS3BA048KA, 4 tons.)

Comments:

Ventilation2.

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Page: 285 of 499

Building: 07-180 - TCU

Comments: Underground service for this building is provided from a pole-mounted center-owned transformer bank, located at the east side of the building, to a 600A main switchboard (Square D, I-Line, E1) with a 500A main circuit breaker. The switchboard has (6) 100A and (1) 250A circuit breakers, and serves six 225A main-lug-only (MLO) panels located one in each shop and one two-section 225A MLO panel located in the mechanical room and serving north building's end.

FIRE ALARM

Comments: The fire alarm panel is a Silent Knight 2224.

Comments: The building is connected to the center LAN system for data communications.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None Local Cable Company

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Compact Fluorescent High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Classrooms

Storage Rooms

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 2

COMMUNICATION

Electric Water Gas No NoNo

Page: 286 of 499

Building: 07-180 - TCU

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

BUILDING 07 200 COMMUNITY LIFE / HUB / SECURITYBUILDING 07-200 - COMMUNITY LIFE / HUB / SECURITY

Page: 287 of 499

Building: 07-200 - COMMUNITY LIFE / HUB / SECURITY

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Structural Steel Steel

CMU Masonry

Wall Roof Batt Rigid

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Business 10,340 6,844 1 Owned 1990 Unevaluated

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

Yes

Yes

N/A

ACCESSIBILITY

Structural Systems1.

Exterior Walls2. Number of Deficiencies = 1

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Metal Gutters and Downspouts 1990 19 Gable Entire Building

3. Roof

Page: 288 of 499

Building: 07-200 - COMMUNITY LIFE / HUB / SECURITY

INTERIOR FINISH

Ceramic Tile Concrete Vinyl Tile

CMU Ceramic Tile Drywall

Wood Unit - Metal Frame

Mechanical Restroom

Ventilation Area Served

VERTICAL CIRCULATION

None

Single Hung - Aluminum Frame; Double Glazing;

Acoustical Tile Gypsum Board

Exhaust Ventilation

Number of Deficiencies = 2

Windows6.

Floors1.

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

There are six vertical, upflow furnaces manufacturered by Bryant, Trane and York some of which are actually two furnaces in a twinned arrangement operating and controlled as one.

Comments:

HVAC

Heat1.

Gas-Fired Furnace

Single Duct None Electric Mechanical None Entire Building

Page: 289 of 499

Building: 07-200 - COMMUNITY LIFE / HUB / SECURITY

The water heater was built by A.O. Smith (#BT120880, 96 MBH output, 75 gallon tank).Comments:

Cast Iron/PVC None None

Electric Water Cooler Hose Bibb Lavatory Mop Sink Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Packaged Direct

Expansion (Air Source)

Single Duct

Window Unit

Refrigerant

None

Electric

Electric

Mechanical

Natural

None

None

Entire Building

Offices

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The cooling is produced by six condensing units built by three manufacturers (a Trane #2TTB0036A1, 3 tons, built 8/2003; three Trane #TTA090A300FA, 7-1/2 tons each, built 2002 & 2004; a Rheem #RAWD076CAZ, 7-1/2 tons, built 6/2001 and a Bryant #563CNX036D, 3 tons). Each of these units operate in conjunction with one of the six furnaces that each have a DX evaporator coil mounted on the discharge.

There are a couple of window units in the former director of community life's office.

Comments:

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Page: 290 of 499

Building: 07-200 - COMMUNITY LIFE / HUB / SECURITY

Comments: Underground electrical service is provided from a pole-mounted center-owned transformer bank located at the north side of the building to a 600A switch-and-fuse type main switchboard (Westinghouse, FDP- 326R, built 4/90). The switchboard has four 60A, two 100A and two 200A switches, and serves two 225A main-lug-only (MLO) panels (Westinghouse, PRL1, built 4/90), five HVAC units and a kiln.

FIRE ALARM

Comments: The fire alarm panel is an Edwards 6616 located in the main entry.

Comments: This building houses a LAN server room for data communications for most 07-000 series buildings.

This server reports back to the main server at Building 05-214. 25 cameras are used to monitor the center from a color monitor located in the coordinator's office. Additionally, security systems for intrusion detection, installed in Payroll Building 06-106, Center Administration Building 06-104, and several other buildings, report alarm status to this building.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System Closed Circuit TV None Local Cable Company

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Comments: Some battery backup emergency lights are also utilized.

High Intensity Discharge (HID) Incandescent

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Conference Rooms

Corridors & Stairs

Storage Rooms

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Selected Lighting w/ Battery Battery Backup

Switchboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

Number of Deficiencies = 1

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 2

COMMUNICATION

Page: 291 of 499

Building: 07-200 - COMMUNITY LIFE / HUB / SECURITY

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING 07 216 DORMITORYBUILDING 07-216 - DORMITORY

Page: 292 of 499

Building: 07-216 - DORMITORY

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Loadbearing Masonry Steel

Brick Masonry

Wall Roof Batt Batt

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Residential 9,576 7,356 1 Owned 1974 Unevaluated

Comments: There are no visual alarms in laundry and toilet/shower rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

No

No

Yes

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material Drainage Year Life

Remaining Type Area Served

Metal

Metal

Gutters and Downspouts

Surface Run-off

Gable

Mansard

Entire Building

Building Periphery

3. Roof

Page: 293 of 499

Building: 07-216 - DORMITORY

INTERIOR FINISH

Concrete Terrazzo Vinyl Tile

Ceramic Tile Drywall FRP Wood paneling

Metal Unit - Metal Frame Wood Units - Metal Frame

Mechanical Toilet/Shower

Ventilation Area Served

VERTICAL CIRCULATION

None

Casement - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Single Glazing;

Exposed Structure Gypsum Board

Exhaust Ventilation

Number of Deficiencies = 1

Windows6.

Floors1.

Interior Walls2. Number of Deficiencies = 1

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The heating unit is a duct heater (Reznor, approx. 350 MBH) mounted in the return airsteam. It is equipped with a powered flue vent and outdoor air intake. The air is circulated by an air handling unit (Carrier #40RM024B511GC, 8000 CFM, built 11/2002).

Comments:

HVAC

Heat1.

Gas-Fired Furnace

Single Duct None Electric Mechanical None Entire Building

Page: 294 of 499

Building: 07-216 - DORMITORY

The water is heated by two water heaters (a State #SBF100199NET1, built 1995 and a Rheem #GN100200, built 7/2003, both 100 gallon, 160 MBH output).

Comments:

Cast Iron/PVC None None

Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Galvanized Steel/Copper

Copper, Galvanized, PVC

Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The cooling is provided by two condensing units (a Carrier #38ARZ012, built 1/2002 and a Trane #TTA120300DL, built 9/2001, both 10 ton) mounted at grade level on concrete pads. The air is circulated by an air handling unit (Carrier #40RM024B511GC, 8000 CFM, built 11/2002) with two evaporater coils.

Comments:

Number of Deficiencies = 1

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2. Number of Deficiencies = 1

Fixtures3.

Fuel Distribution4.

Page: 295 of 499

Building: 07-216 - DORMITORY

Comments: Underground electrical service is provided from a pole-mounted center-owned transformer bank located at the southwest side of the building to a 400A disconnect fused at 400A located in the mechanical/electrical room. This disconnect serves through the trough two 100A and one 150A single-phase disconnects and one 100A main-lug-only panelboard.

FIRE ALARM

Comments: The fire alarm panel is an ESL 1500 located in the RA office.

Comments: Pay phones are provided for student use. The building is connected to the center LAN system for data communications.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System Magnetic Door/Alarm None Local Cable Company

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution. Compact fluorescent fixtures are utilized in the corridors and lounge area. T12 -fluorescent light fixtures are also utilized throughout the building.

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T8 - Fluorescent

T12 and T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

T8 - Fluorescent

Compact Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

Offices

Sleeping Rooms

Storage Rooms

Corridors & Stairs

Laundry Room

Lounges

Toilets

Shower

Shaving, Make-Up, Grooming

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 2

Exterior Lighting1. Number of Deficiencies = 1

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 1

COMMUNICATION

Page: 296 of 499

Building: 07-216 - DORMITORY

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

Service disconnect and service entrance conductor to the building are too small for the existing load.

Several loadcenters throughout the building are deteriorated. Fire alarm system is deteriorated. Interior finishes are deteriorated.

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Fair Interior: Fair Mechanical: Good Electrical: Fair

This building has been recommended for renovation in the Long Range Development Plan.

RENOVATION RECOMMENDATION

BUILDING 07 217 DORMITORYBUILDING 07-217 - DORMITORY

Page: 297 of 499

Building: 07-217 - DORMITORY

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Loadbearing Masonry Steel

Brick Masonry

Wall Roof Batt Rigid

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Residential 9,576 6,804 1 Owned 1973 Unevaluated

Comments: There are no visual alarms in laundry and toilet/shower rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

No

No

Yes

ACCESSIBILITY

Structural Systems1.

Exterior Walls2.

Insulation4.

Exterior Doors5.

Material

The roofing appears to be in good condition, therefore it should provide protection for another 6 years.

Drainage Year Life

Remaining Type Area Served

Built-up Roofing

Metal

Surface Run-off

Surface Run-off

Flat

Mansard

Entire Building

Building Periphery

Number of Deficiencies = 1

Comments:

3. Roof

Page: 298 of 499

Building: 07-217 - DORMITORY

INTERIOR FINISH

Ceramic Tile Concrete Vinyl Tile

CMU Ceramic Tile Drywall FRP Wood paneling

Metal Unit - Metal Frame Wood Unit - Metal Frame

Mechanical Toilet/Shower

Comments: There are four rooftop exhaust fans serving these spaces.

Ventilation Area Served

VERTICAL CIRCULATION

None

Casement - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Single Glazing;

Exposed structure Gypsum Board

Exhaust Ventilation

Number of Deficiencies = 1

Windows6.

Floors1. Asbestos: Yes

Interior Walls2.

3.

Interior Doors4.

Heat Source

Heat Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

The heating unit is a Reznor duct heater (#HX3008E, 240 MBH output, built 9/1998) mounted in the return airsteam. The air is circulated by an air handling unit (Carrier #40RM024H511HC, 8000 CFM, built 4/2005).

Comments:

HVAC

Heat1.

Gas-Fired Furnace

Single Duct None Electric Natural None Entire Building

Page: 299 of 499

Building: 07-217 - DORMITORY

The water is heated by two water heaters (each a State #SBF100199NET1, 160 MBH output, 100 gallon tank, built in 1996 and 1998).

Comments:

Cast Iron/PVC None None

Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper, Galvanized, PVC

Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct None Electric Natural None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The cooling is provided by two condensing units (Trane #TTA180C300EA, each 10 ton with two compressors, built 4/2010) mounted on the roof. The air is circulated by an air handling unit (Carrier #40RM024H511HC, 8000 CFM, R-410a, built 4/2005) with two evaporater coils.

Comments:

Number of Deficiencies = 1

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation

Measure

Area Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Page: 300 of 499

Building: 07-217 - DORMITORY

Comments: Underground electrical service is provided from a pole-mounted center-owned transformer-banks located at the east side of the building to a 400A disconnect switch with 400A fuses, which in turn serves two 100A panelboards (Square D, NQO-28-304-1), several loadcenters and another disconnect switch fused and rated at 200A providing for HVAC equipment.

FIRE ALARM

Comments: The fire alarm panel is a ESL-1500 located in the RA office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution. Compact fluorescent fixtures are utilized in the corridors and lounge area.

High Intensity Discharge (HID)

Comments: Building-mounted light fixtures are controlled by photocell.

T12 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

T12 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

Offices

Sleeping Rooms

Storage Rooms

Lounges

Laundry Room

Corridors & Stairs

Shower

Toilets

Shaving, Make-Up, Grooming

Equipment Rooms (Elec/Mech)

Area Recommended Level

Recorded Level Light Type

Battery Backup Battery Backup

Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1. Number of Deficiencies = 1

Interior Lighting2.

Emergency /Exit Lighting3.

Type Location Battery Operated Corridor

CARBON MONOXIDE DETECTION

Page: 301 of 499

Building: 07-217 - DORMITORY

Comments: Pay phones are provided for student use. The building is connected to the center LAN system for data communications.

Connected to Main System Magnetic Door/Alarm None Local Cable Company

Telephone Security Public Address Television

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING 07 218 DORMITORYBUILDING 07-218 - DORMITORY

Page: 302 of 499

Building: 07-218 - DORMITORY

BUILDING ENVELOPE

Foundation RoofBuilding

Concrete Loadbearing Masonry Steel

Brick Masonry

Wall Roof None None

Metal Unit - Metal Frame

AccessibilityFeature

GSF NSF Year Built Use Group Historic Ownership#Floors

Residential 9,576 6,770 1 Owned 1973 Unevaluated

Comments: There are no visual alarms in laundry and toilet/shower rooms.

REAL ESTATE

Access to Building

Ramps

Entrance

2nd Egress

Visual Alarm

Corridor/Aisle

Rooms

Stairs

Elevator

Restrooms

Drinking Fountain

Telephone

Yes

N/A

Yes

Yes

Yes

Yes

Yes

N/A

N/A

No

No

Yes

ACCESSI…