This document contains a special notice and interior signage guide for the Defense Health Agency.
The special notice provides information on an upcoming solicitation for an initial outfitting project at Misawa Air Base Hospital in Japan. The project scope includes work for the Dental, Sterile Processing, Nutritional Medicine, and Pharmacy departments. A mobile sterilization unit must also be supplied immediately upon award. The estimated contract value is between $5-10 million. The solicitation will use FAR Part 13 simplified acquisition procedures and FAR Part 12 for commercial items. The requirement is a total small business set-aside under NAICS code 337127 with a size standard of 500 employees. Questions may be asked through October 15th and proposals are due by October 31st. The project completion date is April 2024.
The interior signage guide outlines requirements and standards for Military Health System signage at medical facilities. It includes the MHS logo and examples of primary sign types from the Air Force Interior Design Guide. Emphasis is placed on using the MHS seal and incorporating it on directional and department signs in a tone-on-tone background insert. Removable acrylic inserts with set screws are referenced as the standard to enable easy message changes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| draft SOLICITATION INFORMATION.docx | DOCX document | |
| MABH-SID-Package-Vol3.pdf | ||
| DHA22I Misawa Hospital Modernization IO Bid Schedule 24 Aug 21 .xlsx | XLSX spreadsheet | |
| Specifications_Volume 1_Addendum 02.pdf | ||
| FY21 Misawa Requirement Documents_20210820 v4.docx | DOCX document | |
| Misawa Existing Inventory (G) 2JUN2021.xlsx | XLSX spreadsheet | |
| 06 MABH-Equipment.pdf | ||
| BoDEquipmentCutSheets-LogCATA.pdf | ||
| MABH-SID-Package-Vol2.pdf | ||
| MABH-SID-Package-Vol1.pdf | ||
| 10 MABH-Electrical.pdf | ||
| ProjectContents_20191218_163212.pdf | ||
| PN99822_FP_Misawa Hospital Addition and Alteration_V2.0 (22 Feb 21).pdf | ||
| IFC- Rack Sizing Calculations.pdf | ||
| LVS Division 27 - DHA Specification_Standard 06.14.21.pdf | ||
| draft SOLICITATION INFORMATION.docx | DOCX document | |
| 01 MABH-General.pdf | ||
| 05 MABH-Interiors.pdf | ||
| MABH-FFE-Package.pdf | ||
| 07 MABH-FireProtection.pdf | ||
| Specifications_Vol 2_Addm 01.pdf | ||
| Mobile SPD PWS_mws (003).docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET
DHA Interior Signage & Wayfinding Guide
(AS OF 3/23/2021)
SEE ATTACHED:
Page 1: Exterior signage requirements
Page 2: MHS logo/seal Page 3-32: Excerpts from Air Force Interior
Design Guide
Page 1: DHA Exterior Signage
Page 2: DHA MHS Logo/Seal
Graphic design/signage company to request vector file of MHS logo/seal for accuracy.
Page 3: Excerpt from Air Force Interior Design Signage Guide
Page 4: Excerpt from Air Force Interior Design Signage Guide
Entry lobby signage to be represented by MHS seal not local command shield and to be treated in monumental manner such as this example
Page 5: Excerpt from Air Force Interior Design Signage Guide
*Medium
Page 6: Excerpt from Air Force Interior Design Signage Guide
Page 7: Excerpt from Air Force Interior Design Signage Guide
Page 8: Excerpt from Air Force Interior Design Signage Guide
Page 9: Excerpt from Air Force Interior Design Signage Guide
Set screw is required to lock message panel in place – Air Force uses the removable acrylic window and set screw as their design standard so that it makes it easy for the facility to change out the inserts when they need to be revised. Once the insert is replaced, the set screw locks in the acrylic which prevents any possible tampering or message sliding out.
The set screw is called out to be used on the following sign types in the Air Force Design Guide:
• A1/A2 Primary/secondary room identification
• B1/B2 Large/small changeable message
• D1 Evacuation maps
• G1/G2 Patient rights/Staff rights
• J1/J2 Large/small wall mounted directionals
*Page 10: Excerpt from Air Force Interior Design Signage Guide
Clarification of the set screw in signage
Page 11: Set Screw Clarification Referenced in the Air Force Interior Design Signage Guide
Page 12: Excerpt from Air Force Interior Design Signage Guide
Page 13: Excerpt from Air Force Interior Design Signage Guide
Page 14: Excerpt from Air Force Interior Design Signage Guide
Page 15: Excerpt from Air Force Interior Design Signage Guide
MHS seal to be incorporated in a tone on tone background insert for the Command department
Page 16: Excerpt from Air Force Interior Design Signage Guide
The set screw is called out to be used on the following sign types in the Air Force Design Guide:
• A1/A2 Primary/secondary room identification
• B1/B2 Large/small changeable message
• D1 Evacuation maps
• G1/G2 Patient rights/Staff rights
• J1/J2 Large/small wall mounted directionals
Set screw is required to lock message panel in place – Air Force uses the removable acrylic window and set screw as their design standard so that it makes it easy for the facility to change out the inserts when they need to be revised. Once the insert is replaced, the set screw locks in the acrylic which prevents any possible tampering or message sliding out.*Page 17: Excerpt from Air
Page 18: Excerpt from Air Force Interior Design Signage Guide
Page 19: Excerpt from Air Force Interior Design Signage Guide
Page 20: Excerpt from Air Force Interior Design Signage Guide
• A1/A2 Primary/secondary room identification
• B1/B2 Large/small changeable message
• D1 Evacuation maps
• G1/G2 Patient rights/Staff rights
• J1/J2 Large/small wall mounted directionals
Set screw is required to lock message panel in place – Air Force uses the removable acrylic window and set screw as their design standard so that it makes it easy for the facility to change out the inserts when they need to be revised. Once the insert is replaced, the set screw locks in the acrylic which prevents any possible tampering or message sliding out.*Page 21: Excerpt from Air
Page 22: Excerpt from Air Force Interior Design Signage Guide
Page 23: Excerpt from Air Force Interior Design Signage Guide
Page 24: Excerpt from Air Force Interior Design Signage Guide
• A1/A2 Primary/secondary room identification
• B1/B2 Large/small changeable message
• D1 Evacuation maps
• G1/G2 Patient rights/Staff rights
• J1/J2 Large/small wall mounted directionals
Set screw is required to lock message panel in place – Air Force uses the removable acrylic window and set screw as their design standard so that it makes it easy for the facility to change out the inserts when they need to be revised. Once the insert is replaced, the set screw locks in the acrylic which prevents any possible tampering or message sliding out.*Page 25: Excerpt from Air
Page 26: Excerpt from Air Force Interior Design Signage Guide
The set screw is called out to be used on the following sign types in the Air Force Design Guide:
• A1/A2 Primary/secondary room identification
• B1/B2 Large/small changeable message
• D1 Evacuation maps
• G1/G2 Patient rights/Staff rights
• J1/J2 Large/small wall mounted directionals
Set screw is required to lock message panel in place – Air Force uses the removable acrylic window and set screw as their design standard so that it makes it easy for the facility to change out the inserts when they need to be revised. Once the insert is replaced, the set screw locks in the acrylic which prevents any possible tampering or message sliding out.*Page 27: Excerpt from Air
Page 28: Excerpt from Air Force Interior Design Signage Guide
Page 29: Excerpt from Air Force Interior Design Signage Guide
Page 30: Excerpt from Air Force Interior Design Signage Guide
Page 31: Excerpt from Air Force Interior Design Signage Guide
Page 32: Excerpt from Air Force Interior Design Signage Guide
Page 33: Excerpt from Air Force Interior Design Signage Guide
File details come from the government source that posted it. Updated .