Detroit Oil Transformer Pumps and Motors Specifications.pdf
PDF 98 KB Posted
- Solicitation number
- W9127N26QA135
About this file
This is a Purchase Description for the procurement of twelve (12) centrifugal pumps with induction motors for the Detroit Powerhouse. The pumps are replacements for original equipment over 70 years old that shows signs of imminent failure, including abnormal bearing noise, vibration, and motor insulation degradation. These pumps are critical to the hydropower mission, as they circulate transformer oil for cooling and insulation while maintaining dissolved gas levels essential to fish habitat. Delivery must be made to Detroit Dam, 40990 Highway 22, Mill City, OR 97360, Monday through Thursday between 0700-1600, excluding Federal Holidays, with all shipping costs included in the bid.
The pump specifications require a size of 2-1/2 x 2-1/2 with a 4-1/2 impeller, 50-foot head, and 160 gallons per minute capacity. Pumps must be centrifugal type with heavy-duty class 30 cast iron construction, designed for continuous duty operation between 0 and 40 degrees Celsius, with Viton internal elastomers, Buna N gaskets, and complete sealing. Flange dimensions and all performance criteria must be identical to the original Allis Chalmers type XGHT pump. Motors must be TA frame size 180, 5 horsepower, 3500 RPM, 460V-480V, 3-phase, 60 Hertz, with continuous duty cycle capability, class F insulation, and ability to accept a 60-degree Celsius temperature rise. Contractors must provide shop drawings with all dimensions for technical acceptance prior to award and must furnish complete full-run performance test data with delivery of the pumps.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PURCHASE DESCRIPTION
DETROIT POWERHOUSE TRANSFORMER OIL PUMPS AND MOTORS
Scope:
This Purchase Description (PD) covers the purchase of twelve (12) centrifugal pumps with induction motors, per attached specifications.
Background:
Detroit Powerhouse has five main unit transformers that each require two oil circulation pumps that ensure efficient cooling and insulation by circulating oil through the transformer. The other two pumps will be critical spares. These pumps and motor combinations are mounted in proximity to the transformers and connected through an integrated series of pipes. These pumps are original and are over 70 years old. They have begun to reflect signs suggesting that their end of serviceable life is imminent. Maintenance Technicians have observed abnormal bearing noise to include vibration. Electrical testing has recently revealed a degradation to the motor insulation and windings.
Justification:
Transformer oil circulation pumps and motors are considered critical to the hydropower mission.
Transformers will not be able to maintain precise temperature or adequate insulation, which would result in loss of power generation, and potential damage to equipment. Additionally, the outflow of water from the main units assists with regulating the amount of dissolved gases in the water in respect to other water passage ways such as Spillways, and Regulating Outlet gates. These dissolved gas numbers are critical to fish habitat.
Requirements:
Purchase twelve (12) centrifugal pumps with induction motors, per specifications below and attached drawings, to replace current pumps. For informational purposes only, original manufacturer was Allis Chalmers, type XGHT.
Pumps:
Size: 2-1/2 x 2-1/2 Impeller size: 4-1/2 Head: 50 feet Gallons per minute: 160
Flange dimensions and all performance criteria shall be identical to original pump and motor. The shaft, rotor, and impeller assembly shall be dynamically balanced. Pumping fluid is transformer oil. All internal elastomers shall be Viton and confined groove arrangements. Pumps shall be supplied with Buna N gaskets, or equivalent, for flanges. Pumps shall be centrifugal type and manufactured with heavy-duty class 30 cast iron construction with coatings applied to protect against rust inside and outside. Pumps shall be designed for continuous duty operation in temperatures ranging from 0 degrees Celsius to 40 degrees Celsius. Pumps shall be completely sealed. Pumps must be clocked at 90 degrees clockwise facing the impeller. Pumps are required to be manufactured with certain specific dimensions that must be met, those dimensions are highlighted in red within attached drawing. (see also required data below).
Motors:
Motor Type: TA Frame size: 180 Horsepower: 5
RPM: 3500
Voltage: 460V-480V
Phase: 3 Cycles: 60 Hertz
Motors shall be continuous duty cycle and accept a temperature rise of 60 degrees Celsius. Motors shall be wound with class F insulation. A rotation sight glass shall be installed where applicable. The motor must be suitable to operate on 480V nominal voltage.
Required Data:
Shop drawings of the pump/motor combinations with all applicable dimensions are required to be provided and technically accepted in advance of award. A complete and full-run performance test shall be performed, and the data results shall be forwarded with the pumps.
Shipping:
Pumps shall be delivered to Detroit Dam, 40990 Highway 22, Mill City, OR, 97360. The Government shall not be responsible for the cost of shipping to Detroit Dam and to be included with bid. Deliveries must be made Monday-Thursday between 0700-1600, excluding Federal Holidays.