This document is a Contract Data Requirements List (CDRL) detailing eight specific deliverables for a Computer Room Air Conditioning (CRAC) maintenance and replacement contract at Joint Base Lewis-McChord (JBLM). The deliverables include As-Built Drawings (A001), Work Schedule (A002), Status Reports (A003), Meeting Minutes (A004), Test Reports (A005), Test Plan (A006), OPSEC Plan (A007), and Quality Control Plan (A008). Each deliverable has a specific purpose, such as ensuring proper installation, tracking project progress, documenting unit functionality, and maintaining operational security for critical infrastructure. All deliverables are subject to government acceptance and must meet professional standards outlined in the Performance Work Statement (PWS), and must be produced using government-approved software tools and versions.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DELIVERABLES.
All deliverables are subject to Government acceptance and approval. They shall meet professional standards and the requirements set forth in the Performance Work Statement (PWS).
All deliverables shall be produced using recommended software tools/versions as accepted by the Government. The Contractor shall submit the following deliverables:
CDRL Data Item Title Data Item Description
A001 As-Built Drawings As-built requirements to ensure proper installation of new CRAC units, as well as continuity for future projects on units.
A002 Work Schedule Work schedule required to ensure required tasks for contract are being addressed, and the required timeframe for when tasks will be completed.
A003 Status Report Status reports required to update Customer on CRAC unit functionality.
A004 Meeting Minutes Meeting minutes required to ensure all parties are prepared for meetings and to provide continuity between Contractor and Customer on what was discussed during the meeting.
A005 Test Report Test reports required to provide Customer with CRAC unit functionality.
A006 Test Plan Test plan required to update Customer on what tests will be performed on CRAC units to provide updates to other key personnel on CRAC unit functionality.
A007 OPSEC Plan OPSEC plan required as CRAC units support critical infrastructure to the installation and is also required for work performed on JBLM.
A008 Quality Control Plan Quality control plan required to explain how the contractor will check their own work to ensure it is up to standards outlined in the PWS and verifiable by government Quality Assurance Representatives.
LIST OF DELIVERABLES.