This document includes a roofing plan drawing and details for the Newington VA Medical Center campus in Newington, Connecticut as well as an associated federal contract solicitation.

The roofing plan drawing provides details for the restoration of three separate roof areas totaling approximately 1,000 square feet. It specifies the removal and replacement of roof drains, HVAC unit supports, vent flashing, and perimeter fascia. The drawing also indicates that the existing adhered modified bitumen roofing system and all related flashing will be prepared and cleaned in their entirety to accept a new aliphatic liquid applied roof system.

The related federal contract solicitation is identified as number 36C24123B0001 and seeks bids for a metal coping and roof repair/replacement project at the Newington VA campus. The solicitation includes a Standard Form 1442 and Invitation for Bid but does not specify pricing terms, response dates, or other salient details. The contracting agency is listed as the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWN BY

CGS

APPROVED

A HALL

DATE

P R

O J E

C T

N e w i n g t o n

V

A

M e d i c a l

C e n t e r

A1.4

T h e r m a l

S c a n

R e s t o r a t i o n

Roof Work Plan

DRAWING NAME:

DRAWING NUMBER:

& General Notes

P r o j e c t

O w n e r

L O

C A

T I O

N

DRAWING STATUS:

A1.4

W i l l a r d

A v e

N e w i n g t o n

C

T

DATE No. REVISIONS

Issued for Review:

27 JULY 2022

27 JULY 2022

U S

V e t e r a n s

A f f a i r s

D e p

M e d i c a l

C e n t e r

AutoCAD SHX Text

SITE LOCUS PLAN

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

- WET INSULATION

AutoCAD SHX Text

ROOF SF - 291 SF WET SF - 0 SF DRY SF - 291 SF

AutoCAD SHX Text

- WET INSULATION

AutoCAD SHX Text

ROOF SF - 310 SF WET SF - 0 SF DRY SF - 310 SF

AutoCAD SHX Text

- WET INSULATION

AutoCAD SHX Text

ROOF SF - 407 SF WET SF - 0 SF DRY SF - 407 SF

AutoCAD SHX Text D1.1

AutoCAD SHX Text D16.1

AutoCAD SHX Text D15.1

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.4

AutoCAD SHX Text D1.1

AutoCAD SHX Text D16.1

AutoCAD SHX Text D15.1

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.4

AutoCAD SHX Text D1.1

AutoCAD SHX Text D16.1

AutoCAD SHX Text D15.1

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.4

AutoCAD SHX Text D1.1

AutoCAD SHX Text D16.1

AutoCAD SHX Text D15.1

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.4

AutoCAD SHX Text D1.2

AutoCAD SHX Text D1.2

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.1

AutoCAD SHX Text

DEMOLITION GENERAL WORK NOTES::

AutoCAD SHX Text

XXX

AutoCAD SHX Text

NOTES WITHOUT ARROW INDICATE ENTIRE SPACE/AREA

AutoCAD SHX Text

XXX

AutoCAD SHX Text

NOTES WITH ARROWS INDICATE SPECIFIC AREAS &/OR ITEMS

AutoCAD SHX Text D1

AutoCAD SHX Text

ROOFING/FLASHING

AutoCAD SHX Text D1.2

AutoCAD SHX Text R&D EXISTING FASCIA AND RELATED FLASHING. REFER TO DETAIL 1/A2.1 FOR NEW PERIMETER FASCIA DETAILS. MATCH TO EXISTING METAL. SEE BID FORM UNIT COST FOR REPLACEMENT

AutoCAD SHX Text PREP & CLEAN ADHERED MOD-BIT ROOFING SYSTEM INCLUDING ALL RELATED FLASHING IN ITS ENTIRETY - PREPARE ROOF SURFACE FOR ALIPHATIC LIQUID APPLIED ROOF SYSTEM. SEE DRAWING A1.0 FOR EXISTING ROOF CONSTRUCTION CORE INFORMATION

AutoCAD SHX Text D15

AutoCAD SHX Text

PLUMBING AND HVAC PENETRATIONS

AutoCAD SHX Text D15.2

AutoCAD SHX Text ALL ROOF MOUNTED HVAC UNITS & CONDENSER UNITS ARE TO REMAIN. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA. NEW PITCH POCKETS + SUPPORT BLOCKING TO BE F&I BY THE ROOFING CONTRACTOR - REFER TO DETAILS 7/A2.1 FOR EQUIPMENT SUPPORT AND PITCH POCKET / WORK BOX DETAILS

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.1

AutoCAD SHX Text EXISTING CURB MOUNTED HVAC UNITS / FAN UNIT / DUCT PENETRATIONS TO REMAIN. REFER TO DETAIL 3/A2.1 FOR CURB FLASHING DETAIL. DISCONNECT AND RE-CONNECT BY OWNER'S DESIGNATED CONTRACTOR. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA.

AutoCAD SHX Text EXISTING VENT STACKS TO REMAIN UNLESS NOTED OTHERWISE - ALL VENT PIPE FLASHING F&I BY THE ROOFING CONTRACTOR - REFER TO DRAWING 6/A2.1 FOR VENT FLASHING DETAIL

AutoCAD SHX Text D15.4

AutoCAD SHX Text ALL ROOF DRAINS ARE TO BE REMOVED AND REPLACED WITH NEW CAST IRON ROOF DRAIN ASSEMBLY, INCLUDING TOP SET DECK PLATE AND ADJUSTABLE DECK CLAMP AND CAST IRON STRAINER - TO TIE INTO EXISTING ROOF DRAIN PIPING BY THE ROOFING CONTRACTOR - REFER TO DRAWING 4/A2.1 FOR ROOF DRAIN DETAIL

AutoCAD SHX Text D16.1

AutoCAD SHX Text D16

AutoCAD SHX Text UNLESS NOTED OTHERWISE ALL EXISTING ROOF MOUNTED ELECTRICAL AND COMMUNICATIONS CONDUIT AND RELATED WORK BOXES, CONTROL PANELS, SECURITY CAMERAS, ETC. IS TO BE REMOVED AND/OR RE-WORKED TO ALLOW FOR INSTALLATION OF NEW ROOFING AND FLASHING SYSTEMS BY THE OWNER'S DESIGNATED ELECTRICAL CONTRACTOR. THE ROOFING CONTRACTOR SHALL CAREFULLY COORDINATE AND FACILITATE WORK BETWEEN THE TWO TRADES & THE VA.

AutoCAD SHX Text

ELECTRICAL AND COMMUNICATIONS SYSTEMS

Sheets and Views
2022_VA Newington_CAD-ROOF PLAN 5.1

File details come from the government source that posted it. Updated .