Coping Roof RR Newington_CAD-Detail ROOF PLAN 5.pdf
PDF 313 KB Posted
- Solicitation number
- 36C24123B0001
About this file
This document includes a roofing plan drawing and details for the Newington VA Medical Center campus in Newington, Connecticut as well as an associated federal contract solicitation.
The roofing plan drawing provides details for the restoration of three separate roof areas totaling approximately 1,000 square feet. It specifies the removal and replacement of roof drains, HVAC unit supports, vent flashing, and perimeter fascia. The drawing also indicates that the existing adhered modified bitumen roofing system and all related flashing will be prepared and cleaned in their entirety to accept a new aliphatic liquid applied roof system.
The related federal contract solicitation is identified as number 36C24123B0001 and seeks bids for a metal coping and roof repair/replacement project at the Newington VA campus. The solicitation includes a Standard Form 1442 and Invitation for Bid but does not specify pricing terms, response dates, or other salient details. The contracting agency is listed as the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY
CGS
APPROVED
A HALL
DATE
P R
O J E
C T
N e w i n g t o n
V
A
M e d i c a l
C e n t e r
A1.4
T h e r m a l
S c a n
R e s t o r a t i o n
Roof Work Plan
DRAWING NAME:
DRAWING NUMBER:
& General Notes
P r o j e c t
O w n e r
L O
C A
T I O
N
DRAWING STATUS:
A1.4
W i l l a r d
A v e
N e w i n g t o n
C
T
DATE No. REVISIONS
Issued for Review:
27 JULY 2022
27 JULY 2022
U S
V e t e r a n s
A f f a i r s
D e p
M e d i c a l
C e n t e r
AutoCAD SHX Text
SITE LOCUS PLAN
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
- WET INSULATION
AutoCAD SHX Text
ROOF SF - 291 SF WET SF - 0 SF DRY SF - 291 SF
AutoCAD SHX Text
- WET INSULATION
AutoCAD SHX Text
ROOF SF - 310 SF WET SF - 0 SF DRY SF - 310 SF
AutoCAD SHX Text
- WET INSULATION
AutoCAD SHX Text
ROOF SF - 407 SF WET SF - 0 SF DRY SF - 407 SF
AutoCAD SHX Text D1.1
AutoCAD SHX Text D16.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.4
AutoCAD SHX Text D1.1
AutoCAD SHX Text D16.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.4
AutoCAD SHX Text D1.1
AutoCAD SHX Text D16.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.4
AutoCAD SHX Text D1.1
AutoCAD SHX Text D16.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.4
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text
TYP
AutoCAD SHX Text D1.2
AutoCAD SHX Text
TYP
AutoCAD SHX Text D1.2
AutoCAD SHX Text
TYP
AutoCAD SHX Text D1.2
AutoCAD SHX Text
TYP
AutoCAD SHX Text D1.2
AutoCAD SHX Text
TYP
AutoCAD SHX Text D1.1
AutoCAD SHX Text
DEMOLITION GENERAL WORK NOTES::
AutoCAD SHX Text
XXX
AutoCAD SHX Text
NOTES WITHOUT ARROW INDICATE ENTIRE SPACE/AREA
AutoCAD SHX Text
XXX
AutoCAD SHX Text
NOTES WITH ARROWS INDICATE SPECIFIC AREAS &/OR ITEMS
AutoCAD SHX Text D1
AutoCAD SHX Text
ROOFING/FLASHING
AutoCAD SHX Text D1.2
AutoCAD SHX Text R&D EXISTING FASCIA AND RELATED FLASHING. REFER TO DETAIL 1/A2.1 FOR NEW PERIMETER FASCIA DETAILS. MATCH TO EXISTING METAL. SEE BID FORM UNIT COST FOR REPLACEMENT
AutoCAD SHX Text PREP & CLEAN ADHERED MOD-BIT ROOFING SYSTEM INCLUDING ALL RELATED FLASHING IN ITS ENTIRETY - PREPARE ROOF SURFACE FOR ALIPHATIC LIQUID APPLIED ROOF SYSTEM. SEE DRAWING A1.0 FOR EXISTING ROOF CONSTRUCTION CORE INFORMATION
AutoCAD SHX Text D15
AutoCAD SHX Text
PLUMBING AND HVAC PENETRATIONS
AutoCAD SHX Text D15.2
AutoCAD SHX Text ALL ROOF MOUNTED HVAC UNITS & CONDENSER UNITS ARE TO REMAIN. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA. NEW PITCH POCKETS + SUPPORT BLOCKING TO BE F&I BY THE ROOFING CONTRACTOR - REFER TO DETAILS 7/A2.1 FOR EQUIPMENT SUPPORT AND PITCH POCKET / WORK BOX DETAILS
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.1
AutoCAD SHX Text EXISTING CURB MOUNTED HVAC UNITS / FAN UNIT / DUCT PENETRATIONS TO REMAIN. REFER TO DETAIL 3/A2.1 FOR CURB FLASHING DETAIL. DISCONNECT AND RE-CONNECT BY OWNER'S DESIGNATED CONTRACTOR. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA.
AutoCAD SHX Text EXISTING VENT STACKS TO REMAIN UNLESS NOTED OTHERWISE - ALL VENT PIPE FLASHING F&I BY THE ROOFING CONTRACTOR - REFER TO DRAWING 6/A2.1 FOR VENT FLASHING DETAIL
AutoCAD SHX Text D15.4
AutoCAD SHX Text ALL ROOF DRAINS ARE TO BE REMOVED AND REPLACED WITH NEW CAST IRON ROOF DRAIN ASSEMBLY, INCLUDING TOP SET DECK PLATE AND ADJUSTABLE DECK CLAMP AND CAST IRON STRAINER - TO TIE INTO EXISTING ROOF DRAIN PIPING BY THE ROOFING CONTRACTOR - REFER TO DRAWING 4/A2.1 FOR ROOF DRAIN DETAIL
AutoCAD SHX Text D16.1
AutoCAD SHX Text D16
AutoCAD SHX Text UNLESS NOTED OTHERWISE ALL EXISTING ROOF MOUNTED ELECTRICAL AND COMMUNICATIONS CONDUIT AND RELATED WORK BOXES, CONTROL PANELS, SECURITY CAMERAS, ETC. IS TO BE REMOVED AND/OR RE-WORKED TO ALLOW FOR INSTALLATION OF NEW ROOFING AND FLASHING SYSTEMS BY THE OWNER'S DESIGNATED ELECTRICAL CONTRACTOR. THE ROOFING CONTRACTOR SHALL CAREFULLY COORDINATE AND FACILITATE WORK BETWEEN THE TWO TRADES & THE VA.
AutoCAD SHX Text
ELECTRICAL AND COMMUNICATIONS SYSTEMS
| Sheets and Views |
| 2022_VA Newington_CAD-ROOF PLAN 5.1 |
File details come from the government source that posted it. Updated .