This document package includes construction drawings and specifications for a roof repair and replacement project, along with details of a related federal contract opportunity. The drawings show the existing roof and parapet wall conditions at the Newington VA Medical Center in Newington, Connecticut and specify a fluid applied reinforced aliphatic roof membrane system to be installed over the primed modified bitumen roof. Key components include new insulation, flashing details at drains, walls, equipment and other penetrations. The related solicitation is for metal coping and roof repair/replacement work at the Newington campus under Solicitation Number 36C24123B0001. The Department of Veterans Affairs Veterans Health Administration VISN 1 is the contracting agency. The bid response due date is not provided.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWN BY

CGS

APPROVED

A HALL

DATE

P R

O J E

C T

N e w i n g t o n

V

A

M e d i c a l

C e n t e r

A2.1

T h e r m a l

S c a n

R e s t o r a t i o n

DRAWING NAME:

DRAWING NUMBER:

DETAILS

P r o j e c t

O w n e r

L O

C A

T I O

N

DRAWING STATUS:

W i l l a r d

A v e

N e w i n g t o n

C

T

DATE No. REVISIONS

Issued for Review:

27 JULY 2022

27 JULY 2022

U S

V e t e r a n s

A f f a i r s

D e p

M e d i c a l

C e n t e r

AutoCAD SHX Text

ROOF RESTORATION

AutoCAD SHX Text

FM ROOF NAV - N/A (ROOF RESTORATION)

AutoCAD SHX Text

SLOPED STRUCTURAL DECK (VARIES)

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC ROOF MEMBRANE SYSTEM OVER PRIMED MOD-BIT - BASE COAT APPLIED @ 3 GAL/SQ. (48 MIL. WET THICKNESS) WITH EMBEDDED GLASS MAT REINFORCING - INSTALL TOP COAT OVER CURED BASE COAT & REINFORCING @ 2 GAL/SQ. (32 MIL. WET THICKNESS) INSTALLED PER MANUFACTURER'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

EXISTING STRUCTURAL DECK TO REMAIN - SLOPE VARIES (VIF)

AutoCAD SHX Text CLEAN AND PRIME EXISTING AND NEW MOD BIT MEMBRANES PER SPECS. PRIOR TO INSTALLING FLUID APPLIED MEMBRANE (TYP)

AutoCAD SHX Text NEW FLAT & TAPERED STOCK STOCK POLYISOCYANURATE POLYISOCYANURATE POLYISOCYANURATE INSULATION TO ALIGN WITH EXISTING TO REMAIN - ADHERE TO PRIMED DECK WITH LOW RISE FOAM PER SPECS.

AutoCAD SHX Text NEW MOD-BIT MEMBRANE FULLY ADHERED TO INSULATION & STRIPPED IN TO EXISTING MOD-BIT TO REMAIN PER SPECS. (TYP)

AutoCAD SHX Text REMOVE ALL EXISTING ISOCYANURATE INSULATION AND ANY UNDERLYING ROOFING TO STRUCTURAL DECK FOR 1'MIN. OUTSIDE ANY WET AREAS OF INSULATION IDENTIFIED (TYP)

AutoCAD SHX Text EXISTING ADHERED MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

16 OZ. COPPER WORK BOX BASE FLASHING

AutoCAD SHX Text

WITH 4"MIN. WIDE FLANGE - SET IN SPECIFIED

AutoCAD SHX Text

SEALANT & FASTEN @ 3" O.C. (MIN) OVER TPO

AutoCAD SHX Text

NEW 16 OZ. STAINLESS-STEEL OR ZINC

AutoCAD SHX Text

CRIMP AND SOLDERED JOINT BETWEEN

AutoCAD SHX Text

PROVIDE P.T. WOOD BLOCKING

AutoCAD SHX Text

COATED COPPER CAP- PITCH TO DRAIN

AutoCAD SHX Text

CAP AND BASE FLASHING CONTINUOUS

AutoCAD SHX Text

ALL SIDES OF BOX-OUT

AutoCAD SHX Text

FILL BOX-OUT WITH FIBERGLASS BATT

AutoCAD SHX Text

INSULATION BY ROOFING CONTRACTOR

AutoCAD SHX Text

SEAL PENETRATION IN WATER

AutoCAD SHX Text

CUT-OFF MASTIC

AutoCAD SHX Text

TYPICAL NEW WORK BOX FLASHING DETAIL

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PRIMED MOD-BIT FLASHING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

CAREFULLY BEND UP EXISTING THRU WALL FLASHING

AutoCAD SHX Text

TO INSTALL NEW WORK - SOLDER ALL SEAMS

AutoCAD SHX Text

WATERTIGHT AFTER RE-SETTING (TYP)

AutoCAD SHX Text

FLUID APPLIED FLASHING DETAIL @ BASE FLASHING

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN - WALL CONSTRUCTION VARIES, V.I.F. (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text GRIND SMOOTH & PRIME STEEL VENT PIPE OR EQUIPMENT PENETRATION WITH METAL PRIMER PRIOR TO ALIPHATIC FLASHING INSTALLATION PER SPECIFICATIONS (TYP)

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED TO 8" MIN. ABOVE ROOF SURFACE OVER PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT MOD-BIT IN STRICT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text A2.1

AutoCAD SHX Text

FLUID APPLIED FLASHING DETAIL @ VENT PIPE*

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED OVER PRIMED METAL SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)

AutoCAD SHX Text EXISTING MASONRY PARAPET CONSTRUCTION TO BE REPAIRED & STONES TO BE REPAIRED AS NEEDED. NEW METAL COPING IS TO BE INSTALLED ON ALL MASONRY OR CONCRETE PARAPETS.

AutoCAD SHX Text SEAL JOINT BETWEEN COPING AND LIMIT OF FLUID APPLIED FLASHING WITH COMPATIBLE URETHANE SEALANT AND BACKER ROD (TYP)

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PARAPET OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text ALPHAGUARD FLUID APPLIED REINFORCED ALIPHATIC MEMBRANE SYSTEM INSTALLED OVER PRIMED MOD-BIT MEMBRANE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text NEW CAST-IRON ROOF DRAIN WITH TOP SET DECK PLATE, ADJUSTABLE EXTENSION MOUNTING KIT AND CAST-IRON STRAINER - PRIME PER SPEC. (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT AND DOWN INTO DRAIN RING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text INFILL OPENING BETWEEN NEW DRAIN BODY AND CONCRETE DECK WITH SPRAY FOAM INSULATION (TYP)

AutoCAD SHX Text TOP MOUNT ROOF DRAIN DECK PAN - SECURE TO CONCRETE DECK & MODIFY OPENING AS REQUIRED TO FIT (TYP)

AutoCAD SHX Text REPLACE MOD-BIT TARGET AROUND DRAIN SUMP WITH NEW MOD-BIT AND TIE INTO NEW DRAIN BODY AND EXISTING SURROUNDING MOD-BIT MEMBRANE TO REMAIN (TYP)

AutoCAD SHX Text PRE-FORMED 4'X4' TAPERED SUMP AT ROOF DRAIN TO TRANSITION SMOOTHLY TO HEIGHT OF ADJACENT INSULATION (TYP)

AutoCAD SHX Text TIE NEW ROOF DRAIN BODY TO DRAIN PIPING BY PLUMBER - VERIFY EXIST PIPE SIZE PRIOR TO ORDER (TYP)

AutoCAD SHX Text REFER TO PLANS FOR EXACT EXTENT OF DRAIN REPLACEMENT / REPAIR & REPLACEMENT OF WET INSULATION AT EXISTING SUMPS - AT EXISTING DRAINS TO REMAIN REMOVE CLAMPING RING TO ALLOW FOR INSTALLATION OF FLUID APPLIED FLASHING PER MFGR'S SPECS & RE-INSTALL AFTER COMPLETING FLASHING (TYP)

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

CAST IRON ROOF DRAIN FLUID APPLIED FLASHING DETAIL

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text EXISTING PERIMETER WOOD BLOCKING, METAL FASCIA AND RELATED ACCESSORIES TO REMAIN UNLESS NOTED OTHERWISE (TYP)

AutoCAD SHX Text EXISTING METAL FASCIA TO REMAIN -MECHANICALLY GRIND MECHANICALLY GRIND SURFACE TO BRIGHT METAL IN AREAS TO RECEIVE FLUID APPLIED FLASHING & PRIME WITH M PRIME PER SPECS. (TYP) (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT AND PRIMED FASCIA IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text A2.1

AutoCAD SHX Text

FLUID APPLIED FLASHING DETAIL @ EXIST FASCIA

AutoCAD SHX Text

FLUID APPLIED PARAPET WALL FLASHING DETAIL

AutoCAD SHX Text REPAIR AND RE-ATTACH FASCIA AND FLANGE AS REQUIRED WITH MFGR'S APPROVED FASTENERS AND FLASHING SHEET AS REQUIRED PRIOR TO FLUID APPLIED FLASHING INSTALLATION (TYP)

AutoCAD SHX Text CAREFULLY BEND UP BACK LEG OF EXIST COPING TO ALLOW FOR INSTALLATION OF FLUID APPLIED FLASHING - RE-SECURE WITH S.S. NEOPRENE GASKETED FASTENERS @ 8" O.C. MAX. (TYP)

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)

AutoCAD SHX Text CAREFULLY REMOVE EXISTING PITCH POCKET, FILLER AND RELATED MATERIALS TO DECK AROUND EXISTING UTILITIES TO REMAIN (TYP)

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

(*ROUND HVAC DUCT FLASHING SIMILAR)

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PRIMED MOD-BIT FLASHING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT MOD-BIT IN STRICT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text CONT. URETHANE CORNER BEAD TO MAKE SMOOTH TRANSITION AT ALL 90 DEG. INTERSECTIONS AS REQUIRED (TYP)

AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)

AutoCAD SHX Text

FLUID APPLIED FLASHING DETAIL AT HVAC CURB

AutoCAD SHX Text SEAL JOINT BETWEEN HVAC UNIT AND LIMIT OF FLUID APPLIED FLASHING WITH COMPATIBLE URETHANE SEALANT AND BACKER ROD (TYP)

AutoCAD SHX Text

CURB-MOUNTED EQUIPMENT AND INS. CURB CONSTRUCTION TO REMAIN (TYP)

AutoCAD SHX Text A2.1

AutoCAD SHX Text A2.1

AutoCAD SHX Text A2.1

AutoCAD SHX Text A2.1

AutoCAD SHX Text A2.1

AutoCAD SHX Text

NOTE:

Sheets and Views
2022_VA Newington_CAD-A2.1