Coping Roof RR Newington_CAD Details-A2_1.pdf
PDF 477 KB Posted
- Solicitation number
- 36C24123B0001
About this file
This document package includes construction drawings and specifications for a roof repair and replacement project, along with details of a related federal contract opportunity. The drawings show the existing roof and parapet wall conditions at the Newington VA Medical Center in Newington, Connecticut and specify a fluid applied reinforced aliphatic roof membrane system to be installed over the primed modified bitumen roof. Key components include new insulation, flashing details at drains, walls, equipment and other penetrations. The related solicitation is for metal coping and roof repair/replacement work at the Newington campus under Solicitation Number 36C24123B0001. The Department of Veterans Affairs Veterans Health Administration VISN 1 is the contracting agency. The bid response due date is not provided.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY
CGS
APPROVED
A HALL
DATE
P R
O J E
C T
N e w i n g t o n
V
A
M e d i c a l
C e n t e r
A2.1
T h e r m a l
S c a n
R e s t o r a t i o n
DRAWING NAME:
DRAWING NUMBER:
DETAILS
P r o j e c t
O w n e r
L O
C A
T I O
N
DRAWING STATUS:
W i l l a r d
A v e
N e w i n g t o n
C
T
DATE No. REVISIONS
Issued for Review:
27 JULY 2022
27 JULY 2022
U S
V e t e r a n s
A f f a i r s
D e p
M e d i c a l
C e n t e r
AutoCAD SHX Text
ROOF RESTORATION
AutoCAD SHX Text
FM ROOF NAV - N/A (ROOF RESTORATION)
AutoCAD SHX Text
SLOPED STRUCTURAL DECK (VARIES)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC ROOF MEMBRANE SYSTEM OVER PRIMED MOD-BIT - BASE COAT APPLIED @ 3 GAL/SQ. (48 MIL. WET THICKNESS) WITH EMBEDDED GLASS MAT REINFORCING - INSTALL TOP COAT OVER CURED BASE COAT & REINFORCING @ 2 GAL/SQ. (32 MIL. WET THICKNESS) INSTALLED PER MANUFACTURER'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
EXISTING STRUCTURAL DECK TO REMAIN - SLOPE VARIES (VIF)
AutoCAD SHX Text CLEAN AND PRIME EXISTING AND NEW MOD BIT MEMBRANES PER SPECS. PRIOR TO INSTALLING FLUID APPLIED MEMBRANE (TYP)
AutoCAD SHX Text NEW FLAT & TAPERED STOCK STOCK POLYISOCYANURATE POLYISOCYANURATE POLYISOCYANURATE INSULATION TO ALIGN WITH EXISTING TO REMAIN - ADHERE TO PRIMED DECK WITH LOW RISE FOAM PER SPECS.
AutoCAD SHX Text NEW MOD-BIT MEMBRANE FULLY ADHERED TO INSULATION & STRIPPED IN TO EXISTING MOD-BIT TO REMAIN PER SPECS. (TYP)
AutoCAD SHX Text REMOVE ALL EXISTING ISOCYANURATE INSULATION AND ANY UNDERLYING ROOFING TO STRUCTURAL DECK FOR 1'MIN. OUTSIDE ANY WET AREAS OF INSULATION IDENTIFIED (TYP)
AutoCAD SHX Text EXISTING ADHERED MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
16 OZ. COPPER WORK BOX BASE FLASHING
AutoCAD SHX Text
WITH 4"MIN. WIDE FLANGE - SET IN SPECIFIED
AutoCAD SHX Text
SEALANT & FASTEN @ 3" O.C. (MIN) OVER TPO
AutoCAD SHX Text
NEW 16 OZ. STAINLESS-STEEL OR ZINC
AutoCAD SHX Text
CRIMP AND SOLDERED JOINT BETWEEN
AutoCAD SHX Text
PROVIDE P.T. WOOD BLOCKING
AutoCAD SHX Text
COATED COPPER CAP- PITCH TO DRAIN
AutoCAD SHX Text
CAP AND BASE FLASHING CONTINUOUS
AutoCAD SHX Text
ALL SIDES OF BOX-OUT
AutoCAD SHX Text
FILL BOX-OUT WITH FIBERGLASS BATT
AutoCAD SHX Text
INSULATION BY ROOFING CONTRACTOR
AutoCAD SHX Text
SEAL PENETRATION IN WATER
AutoCAD SHX Text
CUT-OFF MASTIC
AutoCAD SHX Text
TYPICAL NEW WORK BOX FLASHING DETAIL
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PRIMED MOD-BIT FLASHING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CAREFULLY BEND UP EXISTING THRU WALL FLASHING
AutoCAD SHX Text
TO INSTALL NEW WORK - SOLDER ALL SEAMS
AutoCAD SHX Text
WATERTIGHT AFTER RE-SETTING (TYP)
AutoCAD SHX Text
FLUID APPLIED FLASHING DETAIL @ BASE FLASHING
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN - WALL CONSTRUCTION VARIES, V.I.F. (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text GRIND SMOOTH & PRIME STEEL VENT PIPE OR EQUIPMENT PENETRATION WITH METAL PRIMER PRIOR TO ALIPHATIC FLASHING INSTALLATION PER SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED TO 8" MIN. ABOVE ROOF SURFACE OVER PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT MOD-BIT IN STRICT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
FLUID APPLIED FLASHING DETAIL @ VENT PIPE*
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED OVER PRIMED METAL SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)
AutoCAD SHX Text EXISTING MASONRY PARAPET CONSTRUCTION TO BE REPAIRED & STONES TO BE REPAIRED AS NEEDED. NEW METAL COPING IS TO BE INSTALLED ON ALL MASONRY OR CONCRETE PARAPETS.
AutoCAD SHX Text SEAL JOINT BETWEEN COPING AND LIMIT OF FLUID APPLIED FLASHING WITH COMPATIBLE URETHANE SEALANT AND BACKER ROD (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PARAPET OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text ALPHAGUARD FLUID APPLIED REINFORCED ALIPHATIC MEMBRANE SYSTEM INSTALLED OVER PRIMED MOD-BIT MEMBRANE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text NEW CAST-IRON ROOF DRAIN WITH TOP SET DECK PLATE, ADJUSTABLE EXTENSION MOUNTING KIT AND CAST-IRON STRAINER - PRIME PER SPEC. (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT AND DOWN INTO DRAIN RING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text INFILL OPENING BETWEEN NEW DRAIN BODY AND CONCRETE DECK WITH SPRAY FOAM INSULATION (TYP)
AutoCAD SHX Text TOP MOUNT ROOF DRAIN DECK PAN - SECURE TO CONCRETE DECK & MODIFY OPENING AS REQUIRED TO FIT (TYP)
AutoCAD SHX Text REPLACE MOD-BIT TARGET AROUND DRAIN SUMP WITH NEW MOD-BIT AND TIE INTO NEW DRAIN BODY AND EXISTING SURROUNDING MOD-BIT MEMBRANE TO REMAIN (TYP)
AutoCAD SHX Text PRE-FORMED 4'X4' TAPERED SUMP AT ROOF DRAIN TO TRANSITION SMOOTHLY TO HEIGHT OF ADJACENT INSULATION (TYP)
AutoCAD SHX Text TIE NEW ROOF DRAIN BODY TO DRAIN PIPING BY PLUMBER - VERIFY EXIST PIPE SIZE PRIOR TO ORDER (TYP)
AutoCAD SHX Text REFER TO PLANS FOR EXACT EXTENT OF DRAIN REPLACEMENT / REPAIR & REPLACEMENT OF WET INSULATION AT EXISTING SUMPS - AT EXISTING DRAINS TO REMAIN REMOVE CLAMPING RING TO ALLOW FOR INSTALLATION OF FLUID APPLIED FLASHING PER MFGR'S SPECS & RE-INSTALL AFTER COMPLETING FLASHING (TYP)
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CAST IRON ROOF DRAIN FLUID APPLIED FLASHING DETAIL
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text EXISTING PERIMETER WOOD BLOCKING, METAL FASCIA AND RELATED ACCESSORIES TO REMAIN UNLESS NOTED OTHERWISE (TYP)
AutoCAD SHX Text EXISTING METAL FASCIA TO REMAIN -MECHANICALLY GRIND MECHANICALLY GRIND SURFACE TO BRIGHT METAL IN AREAS TO RECEIVE FLUID APPLIED FLASHING & PRIME WITH M PRIME PER SPECS. (TYP) (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT AND PRIMED FASCIA IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
FLUID APPLIED FLASHING DETAIL @ EXIST FASCIA
AutoCAD SHX Text
FLUID APPLIED PARAPET WALL FLASHING DETAIL
AutoCAD SHX Text REPAIR AND RE-ATTACH FASCIA AND FLANGE AS REQUIRED WITH MFGR'S APPROVED FASTENERS AND FLASHING SHEET AS REQUIRED PRIOR TO FLUID APPLIED FLASHING INSTALLATION (TYP)
AutoCAD SHX Text CAREFULLY BEND UP BACK LEG OF EXIST COPING TO ALLOW FOR INSTALLATION OF FLUID APPLIED FLASHING - RE-SECURE WITH S.S. NEOPRENE GASKETED FASTENERS @ 8" O.C. MAX. (TYP)
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text EXISTING ADHERED MOD-BIT MEMBRANE, ISOCYANURATE INSULATION AND UNDERLYING ROOF CONSTRUCTION TO REMAIN (VIF)
AutoCAD SHX Text CAREFULLY REMOVE EXISTING PITCH POCKET, FILLER AND RELATED MATERIALS TO DECK AROUND EXISTING UTILITIES TO REMAIN (TYP)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
(*ROUND HVAC DUCT FLASHING SIMILAR)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PRIMED MOD-BIT FLASHING IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PRIMED MOD-BIT IN STRICT MOD-BIT IN STRICT IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text CONT. URETHANE CORNER BEAD TO MAKE SMOOTH TRANSITION AT ALL 90 DEG. INTERSECTIONS AS REQUIRED (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOF MEMBRANE AND FLASHING SYSTEM IS TO BE INSTALLED OVER PROPERLY PREPARED & PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
FLUID APPLIED FLASHING DETAIL AT HVAC CURB
AutoCAD SHX Text SEAL JOINT BETWEEN HVAC UNIT AND LIMIT OF FLUID APPLIED FLASHING WITH COMPATIBLE URETHANE SEALANT AND BACKER ROD (TYP)
AutoCAD SHX Text
CURB-MOUNTED EQUIPMENT AND INS. CURB CONSTRUCTION TO REMAIN (TYP)
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text
NOTE:
| Sheets and Views |