About this file

This document includes a roof plan and details for the Newington Metal Coping and Roof Repair/Replacement Project at the Newington CT Campus of the Connecticut VA Health Care System. The project involves repair and replacement of adhered modified bitumen roofing systems and flashing for approximately 1,496 square feet of roof area. Key scope items include removal of the existing roof system, preparation of the roof surface, installation of a new aliphatic liquid applied roof system, replacement of roof drains and pitch pockets, and coordination with other trades for electrical, HVAC and plumbing work. The solicitation number is 36C24123B0001 and bids are due according to Invitation for Bid Solicitation 36C24123B0001. The owner is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWN BY

CGS

APPROVED

A HALL

DATE

P R

O J E

C T

N e w i n g t o n

V

A

M e d i c a l

C e n t e r

A1.1

T h e r m a l

S c a n

R e s t o r a t i o n

Roof Work Plan

DRAWING NAME:

DRAWING NUMBER:

& General Notes

P r o j e c t

O w n e r

L O

C A

T I O

N

DRAWING STATUS:

A1.1

W i l l a r d

A v e

N e w i n g t o n

C

T

DATE No. REVISIONS

Issued for Review:

27 JULY 2022

27 JULY 2022

U S

V e t e r a n s

A f f a i r s

D e p

M e d i c a l

C e n t e r

AutoCAD SHX Text

SITE LOCUS PLAN

AutoCAD SHX Text

- DECKING:

AutoCAD SHX Text

CONCRETE DECK

AutoCAD SHX Text

- INSULATION:

AutoCAD SHX Text

- VAPOR BARRIER:

AutoCAD SHX Text N/A

AutoCAD SHX Text

CORE "A"

AutoCAD SHX Text

- ROOF:

AutoCAD SHX Text

COATED SINGLE PLY

AutoCAD SHX Text

EXISTING ROOF CONSTRUCTION

AutoCAD SHX Text

4" POLYISOCYANURATE INSUALTION

AutoCAD SHX Text

- COVER BOARD:

AutoCAD SHX Text N/A

AutoCAD SHX Text

- WET INSULATION

AutoCAD SHX Text

ROOF PLAN

AutoCAD SHX Text

SCALE: 3/16" = 1'-0"

AutoCAD SHX Text

ROOF SF - 1,496 SF WET SF - 80 SF DRY SF - 1,416 SF

AutoCAD SHX Text

CORE CUTS

AutoCAD SHX Text

CORRIDOR ROOF

AutoCAD SHX Text

ROOF N.I.S.

AutoCAD SHX Text D1.1

AutoCAD SHX Text

DEMOLITION GENERAL WORK NOTES::

AutoCAD SHX Text

XXX

AutoCAD SHX Text

NOTES WITHOUT ARROW INDICATE ENTIRE SPACE/AREA

AutoCAD SHX Text

XXX

AutoCAD SHX Text

NOTES WITH ARROWS INDICATE SPECIFIC AREAS &/OR ITEMS

AutoCAD SHX Text D1

AutoCAD SHX Text

ROOFING/FLASHING

AutoCAD SHX Text D1.2

AutoCAD SHX Text R&D EXISTING FASCIA AND RELATED FLASHING. REFER TO DETAIL 1/A2.1 FOR NEW PERIMETER FASCIA DETAILS. MATCH TO EXISTING METAL. SEE BID FORM UNIT COST FOR REPLACEMENT

AutoCAD SHX Text PREP & CLEAN ADHERED MOD-BIT ROOFING SYSTEM INCLUDING ALL RELATED FLASHING IN ITS ENTIRETY - PREPARE ROOF SURFACE FOR ALIPHATIC LIQUID APPLIED ROOF SYSTEM. SEE DRAWING A1.0 FOR EXISTING ROOF CONSTRUCTION CORE INFORMATION

AutoCAD SHX Text D15

AutoCAD SHX Text

PLUMBING AND HVAC PENETRATIONS

AutoCAD SHX Text D15.2

AutoCAD SHX Text ALL ROOF MOUNTED HVAC UNITS & CONDENSER UNITS ARE TO REMAIN. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA. NEW PITCH POCKETS + SUPPORT BLOCKING TO BE F&I BY THE ROOFING CONTRACTOR - REFER TO DETAILS 7/A2.1 FOR EQUIPMENT SUPPORT AND PITCH POCKET / WORK BOX DETAILS

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.1

AutoCAD SHX Text EXISTING CURB MOUNTED HVAC UNITS / FAN UNIT / DUCT PENETRATIONS TO REMAIN. REFER TO DETAIL 3/A2.1 FOR CURB FLASHING DETAIL. DISCONNECT AND RE-CONNECT BY OWNER'S DESIGNATED CONTRACTOR. IF DISCONNECTION IS REQUIRED COORDINATE WITH VA.

AutoCAD SHX Text EXISTING VENT STACKS TO REMAIN UNLESS NOTED OTHERWISE - ALL VENT PIPE FLASHING F&I BY THE ROOFING CONTRACTOR - REFER TO DRAWING 6/A2.1 FOR VENT FLASHING DETAIL

AutoCAD SHX Text D15.4

AutoCAD SHX Text ALL ROOF DRAINS ARE TO BE REMOVED AND REPLACED WITH NEW CAST IRON ROOF DRAIN ASSEMBLY, INCLUDING TOP SET DECK PLATE AND ADJUSTABLE DECK CLAMP AND CAST IRON STRAINER - TO TIE INTO EXISTING ROOF DRAIN PIPING BY THE ROOFING CONTRACTOR - REFER TO DRAWING 4/A2.1 FOR ROOF DRAIN DETAIL

AutoCAD SHX Text D16.1

AutoCAD SHX Text D16

AutoCAD SHX Text UNLESS NOTED OTHERWISE ALL EXISTING ROOF MOUNTED ELECTRICAL AND COMMUNICATIONS CONDUIT AND RELATED WORK BOXES, CONTROL PANELS, SECURITY CAMERAS, ETC. IS TO BE REMOVED AND/OR RE-WORKED TO ALLOW FOR INSTALLATION OF NEW ROOFING AND FLASHING SYSTEMS BY THE OWNER'S DESIGNATED ELECTRICAL CONTRACTOR. THE ROOFING CONTRACTOR SHALL CAREFULLY COORDINATE AND FACILITATE WORK BETWEEN THE TWO TRADES & THE VA.

AutoCAD SHX Text

ELECTRICAL AND COMMUNICATIONS SYSTEMS

AutoCAD SHX Text D1.1

AutoCAD SHX Text D16.1

AutoCAD SHX Text D15.1

AutoCAD SHX Text D15.3

AutoCAD SHX Text D15.4

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP

AutoCAD SHX Text D1.2

AutoCAD SHX Text

TYP