Construction_Plans.pdf

PDF 2 MB Posted

Attached to
Votran Transfer Plaza Restroom Renovations
Solicitation number
26-B-46LL
Issued by
Volusia County, Florida

About this file

Construction Plans Summary

This is a comprehensive set of construction documents prepared by Hall & Ogle Architects, Inc. for Volusia County, Florida's VOTRAN Transfer Plaza Restroom Renovations project located at 207 Dr. Mary McLeod Bethune Boulevard in Daytona Beach, Florida. The project involves complete renovation of two employee restrooms (men's Room 106 and women's Room 107) including full demolition of existing fixtures, partitions, and finishes, followed by installation of new ADA-compliant plumbing fixtures (lavatories, water closets, and urinals), updated lighting systems with occupancy sensor controls, improved mechanical ventilation with new exhaust fans and ductwork, and durable interior finishes including new ceramic tile flooring, fiberglass reinforced panels for wall surfaces, and acoustical ceiling tiles. The work must be completed in phases to maintain employee break room access and minimize disruptions to facility operations. The project is designed to comply with the 2023 Florida Building Code (including Eighth Edition standards for Building, Accessibility, Energy Conservation, Fuel Gas, Mechanical, and Plumbing), the 2023 NFPA National Electric Code, and the 2023 Florida Fire Prevention Code. Bidders must submit electronic responses via Volusia County's eProcurement Portal by March 12, 2026, at 3:00 p.m., with a non-mandatory pre-bid meeting scheduled for February 13, 2026, at 10:00 a.m., and a question submission deadline of February 26, 2026, at 11:59 p.m. Substantial completion is required within 60 days of Notice to Proceed, with final completion within 30 days thereafter for a total contract duration of 90 days, and liquidated damages assessed at $100 per day for delays beyond the scheduled completion date.

The estimated construction cost for this project is $225,000.00, with the final contract award to be determined upon receipt and evaluation of responsive bids. The County offers a three percent local bid preference to prime contractors maintaining a permanent business location for at least six months in Lake, Orange, Osceola, Seminole, Brevard, or Volusia County, or a two percent preference if subcontractors represent 51 percent or greater of contracted work. All contractors must comply with Federal Transit Administration requirements under FTA Circular 4220.1F, including Davis-Bacon Act prevailing wage compliance and Buy America requirements for manufactured products. A Disadvantaged Business Enterprise participation goal of 5.2% applies, with contractors required to make good faith efforts to meet this goal. Insurance requirements include commercial general liability coverage of $1,000,000 per occurrence and $2,000,000 general aggregate, workers' compensation with Florida statutory limits, and auto liability with $1,000,000 combined single limits. Plumbing fixtures must comply with Volusia County's Preferred Plumbing Fixture List, and any substitutions require prior written approval from County Transit Services/Facilities management. Contractors must submit detailed Schedules of Values and Construction Schedules within 10 days of Notice to Proceed, comprehensive shop drawings and product data, daily construction reports, monthly Applications for Payment with supporting documentation, Site Safety Plans with qualified flaggers and OSHA compliance, and final completion documentation including occupancy permits, warranties, test/adjust/balance records, and as-built documentation in CAD format.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

PROJECT SITE AREA OF WORK

AERIAL VIEW STREET VIEW

DAYTONA BEACH, FLORIDA

VOTRAN TRANSFER PLAZA

RESTROOM RENOVATIONS

HALL & OGLE

ARCHITECTS, INC.

PH (386) 255-6163 208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

JULY 28, 2025100% CONSTRUCTION DOCUMENTS

SCHEDULE OF DRAWINGS

VC PROJECT NO. PC2868

GENERAL NOTES

AutoCAD SHX Text

CS

AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

REVISION/ SUBMISSIONS

AutoCAD SHX Text

SHT. TITLE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PROJECT ARCH:

AutoCAD SHX Text

COMMISSION NO.

AutoCAD SHX Text

DAVID D. OGLE AR93986

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DO

AutoCAD SHX Text

DO

AutoCAD SHX Text

RESTROOM RENOVATIONS

AutoCAD SHX Text

28-JULY-2025

AutoCAD SHX Text

DAYTONA BEACH, FLORIDA

AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.

AutoCAD SHX Text

VOTRAN TRANSFER PLAZA

AutoCAD SHX Text

SC/DO

AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114

AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114

AutoCAD SHX Text

COVER SHEET / SCHEDULE OF DRAWINGS

AutoCAD SHX Text

CS

AutoCAD SHX Text A2.0

AutoCAD SHX Text

FLOOR PLAN / REFLECTED CEILING PLAN

AutoCAD SHX Text D2.0

AutoCAD SHX Text

DEMOLITON PLANS

AutoCAD SHX Text

ARCHITECTURAL

AutoCAD SHX Text

PD111

AutoCAD SHX Text

PLUMBING FLOOR PLANS - DEMO

AutoCAD SHX Text P-001

AutoCAD SHX Text

PLUMBING LEGENDS, SYMBOLS, & SPECS

AutoCAD SHX Text

PLUMBING

AutoCAD SHX Text M-002

AutoCAD SHX Text

MECHANICAL SPECIFICATIONS

AutoCAD SHX Text M-001

AutoCAD SHX Text

MECHANICAL LEGENDS, SYMBOLS, & GENERAL NOTES

AutoCAD SHX Text M-111

AutoCAD SHX Text

MECHANICAL FLOOR PLANS

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text E-002

AutoCAD SHX Text

ELECTRICAL GENERAL NOTES

AutoCAD SHX Text E-001

AutoCAD SHX Text

ELECTRICAL LEGENDS & SYMBOLS

AutoCAD SHX Text E-003

AutoCAD SHX Text

ELECTRICAL SPECIFICATIONS

AutoCAD SHX Text E-101

AutoCAD SHX Text

ELECTRICAL FLOOR PLANS

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text P-111

AutoCAD SHX Text

PLUMBING FLOOR PLANS - NEW

AutoCAD SHX Text P-301

AutoCAD SHX Text

PLUMBING DETAILS

AutoCAD SHX Text A2.1

AutoCAD SHX Text

ELEVATIONS AND DETAILS

AutoCAD SHX Text

ALL CONSTRUCTION TO CONFORM AS APPLICABLE TO THE FOLLOWING CODES:

AutoCAD SHX Text

NFPA NATIONAL ELECTRIC CODE (2023)

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) BUILDING

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) ACCESSIBILITY

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) FBC ENERGY CONSERVATION

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) FUEL GAS

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) MECHANICAL

AutoCAD SHX Text

FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) PLUMBING

AutoCAD SHX Text

FLORIDA FIRE PREVENTION CODE - EIGHTH EDITION (2023)

HALL & OGLE

ARCHITECTS, INC.

PH (386) 255-6163 208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

AutoCAD SHX Text

WOMEN'S

AutoCAD SHX Text

AutoCAD SHX Text

MEN'S

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN'S

AutoCAD SHX Text

AutoCAD SHX Text

MEN'S

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: \"= 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

REVISION/ SUBMISSIONS

AutoCAD SHX Text

SHT. TITLE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PROJECT ARCH:

AutoCAD SHX Text

COMMISSION NO.

AutoCAD SHX Text

DAVID D. OGLE AR93986

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DO

AutoCAD SHX Text

DO

AutoCAD SHX Text

RESTROOM RENOVATIONS

AutoCAD SHX Text

28-JULY-2025

AutoCAD SHX Text

DAYTONA BEACH, FLORIDA

AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.

AutoCAD SHX Text

VOTRAN TRANSFER PLAZA

AutoCAD SHX Text

SC/DO

AutoCAD SHX Text

DEMOLITION FLOOR PLAN

AutoCAD SHX Text D2.0

AutoCAD SHX Text

DEMOLITION PLANS

AutoCAD SHX Text

DEMOLITION NOTES:

AutoCAD SHX Text

1. REMOVE ALL EXISTING PLUMBING FIXTURES 2. REMOVE EXISTING TOILET PARTITIONS 3. REMOVE EXISTING VANITIES 4. REMOVE ALL TILE FLOORING (COVE BASE TO REMAIN) 5. REMOVE PORTION OF GYP. BD. SOFFIT 6. REMOVE ALL EXISTING TOILET ACCESSORIES 7. REMOVE PORTION OF EXISTING STUD WALL 8. REMOVE EXISTING CEILING TILES, GRID TO REMAIN

AutoCAD SHX Text

SCALE: \"= 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

DEMOLITION REFLECTED CEILING PLAN

AutoCAD SHX Text

NOTE 5

AutoCAD SHX Text

NOTE 1

AutoCAD SHX Text

NOTE 1

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text

(TYP.)

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text

NOTE 3

AutoCAD SHX Text

NOTE 3

AutoCAD SHX Text

NOTE 6

AutoCAD SHX Text

NOTE 6

AutoCAD SHX Text

NOTE 7

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text

NOTE 8

AutoCAD SHX Text

NOTE 8

AutoCAD SHX Text

NOTE 4

NOTE 4

PH (386) 255-6163 208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

AutoCAD SHX Text

WOMEN'S

AutoCAD SHX Text

AutoCAD SHX Text

MEN'S

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN'S

AutoCAD SHX Text

AutoCAD SHX Text

MEN'S

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: \"= 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

REVISION/ SUBMISSIONS

AutoCAD SHX Text

SHT. TITLE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PROJECT ARCH:

AutoCAD SHX Text

COMMISSION NO.

AutoCAD SHX Text

DAVID D. OGLE AR93986

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DO

AutoCAD SHX Text

DO

AutoCAD SHX Text

RESTROOM RENOVATIONS

AutoCAD SHX Text

28-JULY-2025

AutoCAD SHX Text

DAYTONA BEACH, FLORIDA

AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.

AutoCAD SHX Text

VOTRAN TRANSFER PLAZA

AutoCAD SHX Text

SC/DO

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text A2.0

AutoCAD SHX Text

FLOOR PLAN / REFLECTED CEILING PLAN

AutoCAD SHX Text

SCALE: \"= 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

REFLECTED CEILING PLAN

AutoCAD SHX Text

INFILL ACOUSTICAL CEILING GRID IN THIS AREA

AutoCAD SHX Text REPLACE ALL ACOUSTICAL CEILING TILES W/ USG SHEETROCK BRAND LAY-IN CLIMAPLUS PANELS, ITEM 3260 OR EQUAL

AutoCAD SHX Text

NEW HVAC DEVICES, SEE MECHANICAL DWG'S.

AutoCAD SHX Text

NEW LIGHT FIXTURES, SEE ELECTRICAL DWG'S.

AutoCAD SHX Text

AutoCAD SHX Text A2.2

AutoCAD SHX Text

AutoCAD SHX Text K

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A2.2

AutoCAD SHX Text

AutoCAD SHX Text A2.2

AutoCAD SHX Text

TOILET ACCESSORY SCHEDULE

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

TOILET AREAS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (36")

AutoCAD SHX Text

MANUFACTURER/MODEL NUMBER

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text

(SM) SOAP DISPENSER

AutoCAD SHX Text

N.I.C. (BY COUNTY)

AutoCAD SHX Text

(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE

AutoCAD SHX Text

BOBRICK B-3699

AutoCAD SHX Text

(SM) TOILET PAPER DISP. (DBL. ROLL)

AutoCAD SHX Text

BOBRICK B-2888

AutoCAD SHX Text G

AutoCAD SHX Text

(SM) SANITARY NAPKIN DISPOSAL

AutoCAD SHX Text

BOBRICK B-254

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text MIRROR (30" x 48")

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (42")

AutoCAD SHX Text B

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text F

AutoCAD SHX Text

BOBRICK B-2908-1836

AutoCAD SHX Text

(SM) MIRROR (18" X 36")

AutoCAD SHX Text H

AutoCAD SHX Text J

AutoCAD SHX Text

COUNTERTOP PAPER TOWEL DISPENSER

AutoCAD SHX Text

TORK 302030

AutoCAD SHX Text K

AutoCAD SHX Text

DROP-IN TRASH CHUTE

AutoCAD SHX Text

BOBRICK B-529

AutoCAD SHX Text L

AutoCAD SHX Text

ROBE HOOK

AutoCAD SHX Text

BOBRICK B-76717

AutoCAD SHX Text

ACCESSORY SCHEDULE NOTES

AutoCAD SHX Text

N.I.C. TO BE SUPPLIED BY OWNER

AutoCAD SHX Text

AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.

AutoCAD SHX Text

AutoCAD SHX Text

SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.

AutoCAD SHX Text

AutoCAD SHX Text

SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.

AutoCAD SHX Text

TOILET ACCESSORY SCHEDULE

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

TOILET AREAS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (36")

AutoCAD SHX Text

MANUFACTURER/MODEL NUMBER

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text

(SM) SOAP DISPENSER

AutoCAD SHX Text

N.I.C. (BY COUNTY)

AutoCAD SHX Text

(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE

AutoCAD SHX Text

BOBRICK B-3699

AutoCAD SHX Text

(SM) TOILET PAPER DISP. (DBL. ROLL)

AutoCAD SHX Text

BOBRICK B-2888

AutoCAD SHX Text G

AutoCAD SHX Text

(SM) SANITARY NAPKIN DISPOSAL

AutoCAD SHX Text

BOBRICK B-254

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text MIRROR (30" x 48")

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (42")

AutoCAD SHX Text B

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text F

AutoCAD SHX Text

BOBRICK B-2908-1836

AutoCAD SHX Text

(SM) MIRROR (18" X 36")

AutoCAD SHX Text H

AutoCAD SHX Text J

AutoCAD SHX Text

COUNTERTOP PAPER TOWEL DISPENSER

AutoCAD SHX Text

TORK 302030

AutoCAD SHX Text K

AutoCAD SHX Text

DROP-IN TRASH CHUTE

AutoCAD SHX Text

BOBRICK B-529

AutoCAD SHX Text L

AutoCAD SHX Text

ROBE HOOK

AutoCAD SHX Text

BOBRICK B-76717

AutoCAD SHX Text

ACCESSORY SCHEDULE NOTES

AutoCAD SHX Text

N.I.C. TO BE SUPPLIED BY OWNER

AutoCAD SHX Text

AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.

AutoCAD SHX Text

AutoCAD SHX Text

SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.

AutoCAD SHX Text

AutoCAD SHX Text

SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.

AutoCAD SHX Text J

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text NEW 12" X 12" PORCELAIN CERAMIC TILE W/ EPOXY GROUT OVER CRACK ISOLATION MEMBRANE, DALTILE HARMONIST, COLOR AS SELECTED BY OWNER

AutoCAD SHX Text TOILET PARTITIONS TO BE SCRANTON HINY HIDERS 55", FLOOR MOUNTED, OVERHEAD BRACED. COLOR: AS SELECTED (TYP.), INSTALL IN SAME LOCATION AS EXISTING PARTITIONS

AutoCAD SHX Text M

AutoCAD SHX Text

HAND DRYER

AutoCAD SHX Text

XLERATOR OR EQUAL

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

PROVIDE SCHLUTER REDUCER STRIP AT EXISTING FLOORING, RENO-U SATIN FINISH

AutoCAD SHX Text

TERMINATE TILE AT EXISTING DOOR THRESHOLD

ALL INTERIOR WALLS TO RECEIVE FRP PANELS OVER THE EXISTING MOSAIC WALL TILE, FROM THE TOP OF THE COVE BASE TO THE CEILING ABOVE, INCLUDING AROUND THE WINDOW OPENINGS, COLOR TO BE SELECTED BY THE OWNER

PH (386) 255-6163 208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

AutoCAD SHX Text

60" MIN.

AutoCAD SHX Text

48" MIN

AutoCAD SHX Text

30" MIN.

AutoCAD SHX Text

60" DIAM. MIN

AutoCAD SHX Text 2'-9 1/2"

AutoCAD SHX Text

2'-1" COUNTER TOP

AutoCAD SHX Text

2'-0" BASE CABINET

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text 2'-8\"

AutoCAD SHX Text 4"

AutoCAD SHX Text 1'-8"

AutoCAD SHX Text 4"

AutoCAD SHX Text

2'-1" COUNTER TOP

AutoCAD SHX Text

2'-0" BASE CABINET

AutoCAD SHX Text 4"

AutoCAD SHX Text 9"

AutoCAD SHX Text 13"

AutoCAD SHX Text

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

REVISION/ SUBMISSIONS

AutoCAD SHX Text

SHT. TITLE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

NO.

AutoCAD SHX Text

PROJECT ARCH:

AutoCAD SHX Text

COMMISSION NO.

AutoCAD SHX Text

DAVID D. OGLE AR93986

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DO

AutoCAD SHX Text

DO

AutoCAD SHX Text

RESTROOM RENOVATIONS

AutoCAD SHX Text

28-JULY-2025

AutoCAD SHX Text

DAYTONA BEACH, FLORIDA

AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.

AutoCAD SHX Text

VOTRAN TRANSFER PLAZA

AutoCAD SHX Text

SC/DO

AutoCAD SHX Text A2.1

AutoCAD SHX Text

ELEVATIONS AND DETAILS

AutoCAD SHX Text

TOILET ACCESSORY SCHEDULE

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

TOILET AREAS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (36")

AutoCAD SHX Text

MANUFACTURER/MODEL NUMBER

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text

(SM) SOAP DISPENSER

AutoCAD SHX Text

N.I.C. (BY COUNTY)

AutoCAD SHX Text

(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE

AutoCAD SHX Text

BOBRICK B-3699

AutoCAD SHX Text

(SM) TOILET PAPER DISP. (DBL. ROLL)

AutoCAD SHX Text

BOBRICK B-2888

AutoCAD SHX Text G

AutoCAD SHX Text

(SM) SANITARY NAPKIN DISPOSAL

AutoCAD SHX Text

BOBRICK B-254

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text MIRROR (30" x 48")

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (42")

AutoCAD SHX Text B

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text F

AutoCAD SHX Text

BOBRICK B-2908-1836

AutoCAD SHX Text

(SM) MIRROR (18" X 36")

AutoCAD SHX Text H

AutoCAD SHX Text J

AutoCAD SHX Text

COUNTERTOP PAPER TOWEL DISPENSER

AutoCAD SHX Text

TORK 302030

AutoCAD SHX Text K

AutoCAD SHX Text

DROP-IN TRASH CHUTE

AutoCAD SHX Text

BOBRICK B-529

AutoCAD SHX Text L

AutoCAD SHX Text

ROBE HOOK

AutoCAD SHX Text

BOBRICK B-76717

AutoCAD SHX Text

ACCESSORY SCHEDULE NOTES

AutoCAD SHX Text

N.I.C. TO BE SUPPLIED BY OWNER

AutoCAD SHX Text

AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.

AutoCAD SHX Text

AutoCAD SHX Text

SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.

AutoCAD SHX Text

AutoCAD SHX Text

SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.

AutoCAD SHX Text

ADA ACCESSIBILITY NOTES

AutoCAD SHX Text

AutoCAD SHX Text

WALL ELEVATION REFERENCE

AutoCAD SHX Text TOILET ROOMS SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR HANDICAPPED ACCESSIBILITY, INCLUDING ALL AMENDMENTS AND REVISIONS TO DATE. MOUNTING HEIGHTS OF FIXTURES AND ACCESSORIES SHALL BE AS FOLLOWS:

AutoCAD SHX Text

WATER CLOSET SEAT HEIGHT - 1'-3" TO 1'-7" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

CENTER LINE OF WATER CLOSET TO SIDE WALL - 1'-6"

AutoCAD SHX Text

AutoCAD SHX Text

FLUSH VALVE HANDLE LOCATED ON APPROACH SIDE OF W.C.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR BEHIND WATER CLOSET - 36" LONG MIN.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR ON SIDE OF WATER CLOSET - 42" LONG MIN.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR MOUNTING HEIGHT- 34" AFF TO CENTER LINE OF BAR.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR DIAMETER - 1 1/2"

AutoCAD SHX Text

AutoCAD SHX Text

SPACE BETWEEN GRAB BAR AND WALL - 1 1/2"

AutoCAD SHX Text

AutoCAD SHX Text

TOILET PAPER DISPENSER - 36" MAX FROM REAR WALL, 30" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

BOTTOM EDGES OF MIRRORS WILL BE A MAX. OF 40" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

KNEE CLEARANCE AT LAVATORY - APRON 29" MIN. HEIGHT, 8" MIN. DEPTH.

AutoCAD SHX Text

AutoCAD SHX Text

LAVATORY RIM SURFACE - 34" MAX AFF.

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE ADA SYMBOL SIGNS FOR MEN'S AND WOMEN'S ADA ACCESSIBLE TOILET ROOMS. SIGNS SHALL BE MOUNTED ON THE EXTERIOR WALL ADJACENT TO THE TOILET ROOM DOOR.

AutoCAD SHX Text

AutoCAD SHX Text FLUSH VALVE HANDLE TO BE POSITIONED TO FACE BASIN SIDE OF ALL ADA ACCESSIBLE TOILER ROOMS AND TOILET STALLS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.

AutoCAD SHX Text

POSITION MIRROR AND LAV. FAUCET CENTER TO LAV. BASIN.

AutoCAD SHX Text

AutoCAD SHX Text

( 5'-0" DIA. TYPICAL )

AutoCAD SHX Text

WHEELCHAIR MANEUVERING CIRCLE

AutoCAD SHX Text

5'-0" DIA

AutoCAD SHX Text

ACCESSIBILITY CLEARANCES

AutoCAD SHX Text NOTE: CLEARANCES AS SHOWN ON FLOOR PLANS PER FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text

( 5'-0" DIA. TYPICAL )

AutoCAD SHX Text

WHEELCHAIR MANEUVERING CIRCLE

AutoCAD SHX Text CLEAR FLOOR OR GROUND SPACE SECTION 305.3 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text CLEARANCE AT WATER CLOSETS SECTION 604 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text

TOILET ACCESSORY SCHEDULE

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

TOILET AREAS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (36")

AutoCAD SHX Text

MANUFACTURER/MODEL NUMBER

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text

(SM) SOAP DISPENSER

AutoCAD SHX Text

N.I.C. (BY COUNTY)

AutoCAD SHX Text

(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE

AutoCAD SHX Text

BOBRICK B-3699

AutoCAD SHX Text

(SM) TOILET PAPER DISP. (DBL. ROLL)

AutoCAD SHX Text

BOBRICK B-2888

AutoCAD SHX Text G

AutoCAD SHX Text

(SM) SANITARY NAPKIN DISPOSAL

AutoCAD SHX Text

BOBRICK B-254

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text MIRROR (30" x 48")

AutoCAD SHX Text

(SM) STAINLESS STEEL GRAB BARS (42")

AutoCAD SHX Text B

AutoCAD SHX Text

BOBRICK B-6806

AutoCAD SHX Text F

AutoCAD SHX Text

BOBRICK B-2908-1836

AutoCAD SHX Text

(SM) MIRROR (18" X 36")

AutoCAD SHX Text H

AutoCAD SHX Text J

AutoCAD SHX Text

COUNTERTOP PAPER TOWEL DISPENSER

AutoCAD SHX Text

TORK 302030

AutoCAD SHX Text K

AutoCAD SHX Text

DROP-IN TRASH CHUTE

AutoCAD SHX Text

BOBRICK B-529

AutoCAD SHX Text L

AutoCAD SHX Text

ROBE HOOK

AutoCAD SHX Text

BOBRICK B-76717

AutoCAD SHX Text

ACCESSORY SCHEDULE NOTES

AutoCAD SHX Text

N.I.C. TO BE SUPPLIED BY OWNER

AutoCAD SHX Text

AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.

AutoCAD SHX Text

AutoCAD SHX Text

SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.

AutoCAD SHX Text

AutoCAD SHX Text

SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.

AutoCAD SHX Text

ADA ACCESSIBILITY NOTES

AutoCAD SHX Text

AutoCAD SHX Text

WALL ELEVATION REFERENCE

AutoCAD SHX Text TOILET ROOMS SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR HANDICAPPED ACCESSIBILITY, INCLUDING ALL AMENDMENTS AND REVISIONS TO DATE. MOUNTING HEIGHTS OF FIXTURES AND ACCESSORIES SHALL BE AS FOLLOWS:

AutoCAD SHX Text

WATER CLOSET SEAT HEIGHT - 1'-3" TO 1'-7" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

CENTER LINE OF WATER CLOSET TO SIDE WALL - 1'-6"

AutoCAD SHX Text

AutoCAD SHX Text

FLUSH VALVE HANDLE LOCATED ON APPROACH SIDE OF W.C.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR BEHIND WATER CLOSET - 36" LONG MIN.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR ON SIDE OF WATER CLOSET - 42" LONG MIN.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR MOUNTING HEIGHT- 34" AFF TO CENTER LINE OF BAR.

AutoCAD SHX Text

AutoCAD SHX Text

GRAB BAR DIAMETER - 1 1/2"

AutoCAD SHX Text

AutoCAD SHX Text

SPACE BETWEEN GRAB BAR AND WALL - 1 1/2"

AutoCAD SHX Text

AutoCAD SHX Text

TOILET PAPER DISPENSER - 36" MAX FROM REAR WALL, 30" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

BOTTOM EDGES OF MIRRORS WILL BE A MAX. OF 40" AFF.

AutoCAD SHX Text

AutoCAD SHX Text

KNEE CLEARANCE AT LAVATORY - APRON 29" MIN. HEIGHT, 8" MIN. DEPTH.

AutoCAD SHX Text

AutoCAD SHX Text

LAVATORY RIM SURFACE - 34" MAX AFF.

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE ADA SYMBOL SIGNS FOR MEN'S AND WOMEN'S ADA ACCESSIBLE TOILET ROOMS. SIGNS SHALL BE MOUNTED ON THE EXTERIOR WALL ADJACENT TO THE TOILET ROOM DOOR.

AutoCAD SHX Text

AutoCAD SHX Text FLUSH VALVE HANDLE TO BE POSITIONED TO FACE BASIN SIDE OF ALL ADA ACCESSIBLE TOILER ROOMS AND TOILET STALLS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.

AutoCAD SHX Text

POSITION MIRROR AND LAV. FAUCET CENTER TO LAV. BASIN.

AutoCAD SHX Text

AutoCAD SHX Text

( 5'-0" DIA. TYPICAL )

AutoCAD SHX Text

WHEELCHAIR MANEUVERING CIRCLE

AutoCAD SHX Text

5'-0" DIA

AutoCAD SHX Text

ACCESSIBILITY CLEARANCES

AutoCAD SHX Text NOTE: CLEARANCES AS SHOWN ON FLOOR PLANS PER FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text

( 5'-0" DIA. TYPICAL )

AutoCAD SHX Text

WHEELCHAIR MANEUVERING CIRCLE

AutoCAD SHX Text CLEAR FLOOR OR GROUND SPACE SECTION 305.3 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text CLEARANCE AT WATER CLOSETS SECTION 604 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.

AutoCAD SHX Text

SOLID SURFACE COUNTER TOP W/ 4" BACKSPLASH

AutoCAD SHX Text

PLAST. LAM. FIN. ALL EXPOSED SURFACES

AutoCAD SHX Text

DROP-IN TRASH CHUTE, BOBRICK B-529

AutoCAD SHX Text

1/4" VENEER CORE PLYWOOD CABINET BACK.

AutoCAD SHX Text

1/4" VENEER CORE PLYWOOD CABINET BACK.

AutoCAD SHX Text

PLYWOOD FRAMING, TYP.

AutoCAD SHX Text

FLEX PIPE IF REQUIRED

AutoCAD SHX Text

WOOD BRACING AS REQ'D

AutoCAD SHX Text

WALL

AutoCAD SHX Text

UNDERMOUNT SINK, (SEE PLUMB. DWGS.)

AutoCAD SHX Text

SOLID SURFACE COUNTERTOP

AutoCAD SHX Text

LATCHABLE PANEL W/ P. LAM. FINISH

AutoCAD SHX Text

BASE CABINET BEYOND WHERE INDICATED ON ELEVATIONS

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

AutoCAD SHX Text A2.2

AutoCAD SHX Text

BASE CABINET W/ LATCHABLE ACCESS PANEL

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

AutoCAD SHX Text A2.2

AutoCAD SHX Text

BASE CABINET W/ DOORS / WASTE OPENING

AutoCAD SHX Text

SCALE: 1\" = 1'-0"

AutoCAD SHX Text

SCALE: 1\" = 1'-0"

AutoCAD SHX Text

SCALE: \" = 1'-0"

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: \" = 1'-0"

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text J

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text K

AutoCAD SHX Text G

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text E

AutoCAD SHX Text H

AutoCAD SHX Text E

AutoCAD SHX Text TOILET PARTITIONS TO BE SCRANTON HINY HIDERS 55", FLOOR MOUNTED, OVERHEAD BRACED. COLOR: AS SELECTED (TYP.)

AutoCAD SHX Text M

AutoCAD SHX Text

STD. GLASS W/ POLISHED EDGES

PLAST. LAM. ON BASE

1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH 2020 FLORIDA

BUILDING CODE - PLUMBING.

2. LOCATE VALVES IN ACCESSIBLE AREAS WHERE NECESSARY. (12"X12" MIN.)

3. COORDINATE ACTUAL LOCATIONS OF MECHANICAL FLOOR DRAINS WITH

FINAL EQUIPMENT LOCATIONS ON SHOP DRAWINGS.

4. VENT PIPING SHOWN IS ONLY FOR DIAGRAMMATIC PURPOSES. COORDINATE

VTRs WITH HVAC AIR INTAKES.

5. LABEL VALVES ABOVE CEILINGS AND IN CONCEALED SPACES AT CEILING TILE

WITH METAL CEILING TACKS INDICATING VALVE # AND TYPE OF WATER. (i.e.;

BLUE= COLD WATER, LETTERING CW VLV1-001).

6. PROVIDE AND INSTALL WATER WATER HAMMER ARRESTORS IN ACCORDANCE

WITH PDI-WH201 IN ALL HW AND CW SUPPLY PIPING WITH QUICK CLOSING

VALVES AS REQUIRED. AIR CHAMBERS ARE NOT ACCEPTABLE

SUBSTITUTIONS.

7. PROVIDE THERMAL INSULATION FOR HOT WATER AND HOT WATER RETURN

PIPING IN ACCORDANCE WITH THE ENERGY EFFICIENCY CODE FOR BUILDING

CONSTRUCTION AND PER SPECIFICATIONS.

8. PROVIDE CLEANOUTS AT THE BASE OF EACH SANITARY STACK. SIZE

CLEANOUTS TO MATCH THE PIPING SERVED. SPACE FLOOR CLEANOUTS AT

100'-0" MAX. ALSO PROVIDE CLEANOUTS IN HORIZONTAL CHANGE OF

DIRECTION > 45°.

9. FIRE CAULK AND SLEEVE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES.

REFER TO LIFE SAFETY PLANS FOR RATED ASSEMBLY LOCATIONS. REFER TO

ARCHITECTURAL SHEETS FOR DETAILS AND UL ASSEMBLY NUMBERS.

10. REFER TO ARCHITECTURAL SHEETS FOR FIXTURE MOUNTING.

11. COORDINATE UNDERGROUND PIPING INVERT ELEVATIONS WITH STRUCTURAL

FOOTING ELEVATIONS AND CIVIL INVERT CONNECTIONS PRIOR TO ANY

UNDERGROUND PIPING INSTALLATIONS. IF FOOTINGS ARE IN CONFLICT AND

WHERE A PIPING ROLL DOWN IS NOT POSSIBLE, COORDINATE WITH GENERAL

CONTRACTOR FOR DROPS IN FOOTING AS REQUIRED.

12. COORDINATE CEILING PIPING AND ELEVATIONS IN SHOP DRAWINGS WITH ALL

OTHER TRADES (I.E. HVAC, FIRE PROTECTION, ELECTRICAL, TELECOMM,

STRUCTURAL, ETC.) PRIOR TO ANY INSTALLATION TO ENSURE PROPER

CLEARANCES AND PENETRATIONS.

13. VALVES AND FITTINGS SHALL BE THE SAME SIZE AS THE PIPING WHERE THEY

ARE LOCATED UNLESS NOTED OTHERWISE.

14. PROVIDE ALL NECESSARY SUPPORTING DEVICES FOR FIXTURES PER

MANUFACTURER INSTALLATION INSTRUCTIONS.

15. PROVIDE ALL FLOOR DRAINS, FLOOR SINKS AND HUB DRAINS WITH DEEP

SEAL P-TRAPS. ALL DRAINS NOT RECEIVING CONTINUOUS DISCHARGE SHALL

BE PROVIDED WITH TRAP PRIMER CONNECTIONS TO ENSURE TRAP SEAL

PROTECTION.

16. ROUGH-IN WASTE AND WATER SUPPLIES FOR FIXTURES AND PERFORM FINAL

CONNECTIONS PER MANUFACTURER RECOMMENDATIONS.

17. ROUGH IN FLUSH VALVE WATER CLOSETS SO THAT THE FLUSH VALVE

HANDLE IS TO THE WIDE SIDE OF THE ROOM.

18. COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY

GUIDELINES FOR BUILDINGS AND FACILITIES.

19. ALL AUTOMATIC CONTROL, PROTECTIVE OR SIGNAL DEVICES REQUIRED FOR

THE OPERATION SPECIFIED, SHALL BE PROVIDED WITH ANY CONTROL WIRING

AND INSTALLED PER MANUFACTURERS REQUIREMENTS.

20. SHOP DRAWING SUBMITTALS SHALL BE FULLY COORDINATED PRIOR TO

SUBMITTAL.

21. PLASTIC VALVES ARE NOT PERMITTED FOR DOMESTIC WATER USE.

22. OFFSET FLANGES ARE PROHIBITED.

PLUMBING ABBREVIATIONSPLUMBING SYMBOL LEGEND

SYMBOL DESCRIPTION

NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT

COMPRESSED AIR PIPINGCA

110° HOT WATER PIPINGHW

HOT WATER RETURN PIPINGHWR

STO STORM OVERFLOW (SECONDARY)

ST STORM (PRIMARY)

SANITARY DRAINAGE PIPING (UNDERGROUND)S U/G

SANITARY DRAINAGE PIPING (ABOVE SLAB)SAN

V VENT PIPING

GATE VALVE

PRESSURE GAUGE

THERMOMETER

CHECK VALVE

BALL VALVE

CIRCULATING PUMP

PIPE END CAP

PIPE TURNING DOWN

PIPE TURNING UP

PIPE TURNING DOWN (TEE)

NATURAL GAS PIPING

CLEANOUTS

CW COLD WATER PIPING

CD CONDENSATE PIPING

CIRCUIT SETTER VALVE

OR

PDI-"?" WATER HAMMER ARRESTER & SIZE

THERMOSTATIC MIXING VALVE

HB-? OR WHY-? HOSE BIBB / WALL HYDRANT

FLOW ARROW

P-TRAP

ROLL DOWN

PIPING TEE

ST U/G STORM PIPING (UNDERGROUND)

G

PRESSURE REGULATING VALVE

BUTTERFLY VALVE

SYMBOL DESCRIPTIONSYMBOL DESCRIPTION

AS ABOVE SLAB

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AP ACCESS PANEL

ASTM AMERICAN STANDARDS TESTING MATERIALS

AWWA AMERICAN WATER WORKS ASSOCIATION

BFP BACKFLOW PREVENTER

BS BELOW SLAB

BF BELOW FLOOR

BG BELOW GRADE

CA COMPRESSED AIR

CD CONDENSATE

CO CLEANOUT

CONN CONNECTION

CONT CONTINUOUS

CP CIRCULATING PUMP

CW COLD WATER

DF DRINKING FOUNTAIN

DFU DRAINAGE FIXTURE UNITS

DIA DIAMETER

DN DOWN

DWG DRAWING

DW DOMESTIC WATER

ECO EXTERIOR CLEANOUT

ELEV ELEVATION

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

ºF DEGREES FAHRENHEIT

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FIN FINISH

FL FLOOR

FPS FEET PER SECOND

FT FEET

FU FIXTURE UNITS

G NATURAL GAS

GAL GALLON(S)

GPM GALLONS PER MINUTE

GR GREASE WASTE

HB HOSE BIBB

HP HORSEPOWER

HR HOUR

HWR HOT WATER RETURN

HZ HERTZ

IE INVERT ELEVATION

ID INTERNAL DIAMETER

IN INCHES

IPS INTERNATIONAL PIPE STANDARD

IRR IRRIGATION WATER

KW KILOWATT

LAV LAVATORY

LF LINEAR FEET

MAX MAXIMUM

MIN MINIMUM

MNTG MOUNTING

MS MOP SINK

NA NOT APPLICABLE

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NSF NATIONAL SANITATION FOUNDATION

NTS NOT TO SCALE

OD OUTSIDE DIAMETER

ORWL OVERFLOW RAIN WATER LEADER

PDI PLUMBING DRAINAGE INSTITUTE

PH PHASE

PPP PRECISION PLUMBING PRODUCTS

PSI POUNDS PER SQUARE INCH

RPM REVOLUTIONS PER MINUTE

RWL RAIN WATER LEADER

S SANITARY

SAN SANITARY

SH SHOWER

SK SINK

SL SODA LINE

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

ST STORM

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TET THERMAL EXPANSION TANK

TMV THERMOSTATIC MIXING VALVE

TP TRAP PRIMER

TYP TYPICAL

UL UNDERWRITER'S LABORATORY

U/G UNDERGROUND

UNO UNLESS NOTED OTHERWISE

UR URINAL

V VENT

VTR VENT THROUGH ROOF

VIV VALVE IN VERTICAL

VLV VALVE

VOL VOLUME

W WATTS

W/ WITH

WC WATER CLOSET

WCO WALL CLEANOUT

WHA WATER HAMMER ARRESTOR

WHY WALL HYDRANT

WFU WATER SUPPLY FIXTURE UNITS

A

B

SIM

A

SECTION SYMBOL:

A = IDENTIFYING LETTER

B = SHEET WHERE SECTION IS SHOWN

SIM =

(ONLY NOTED IF IT APPLIES)

PLUMBING RISER DESIGNATION:

A = RISER IDENTIFYING SYSTEM TYPE

1 =

REVISION CLOUD AND

REVISION NUMBER

SHEET NOTE CALLOUT

A

TITLE SYMBOL ON SHEET WHERE SHOWN

A = IDENTIFYING NUMBER/LETTER

POINT OF CONNECTION

RISER IDENTIFYING SYSTEM NUMBER

SIMILAR

XX

ABBR. DESCRIPTION ABBR. DESCRIPTION

PLUMBING GENERAL NOTES PLUMBING SPECIFICATIONS

GENERAL:

THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK

SPECIFIED IN THIS SECTION.

SCOPE OF WORK:

PROVIDE A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE

DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE

SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO

EQUIPMENT, THE FABRICATION AND/OR INSTALLATION OF THE

SCHEDULED PLUMBING FIXTURES, EQUIPMENT AND RELATED

PIPING. THE COMPLETED PLUMBING SYSTEM SHALL MEET ALL

APPLICABLE STATE & LOCAL CODES AND STANDARDS.

PRODUCTS:

ALL EQUIPMENT, ETC., SHALL BE NEW, AND AS SPECIFIED FREE OF

DEFECTS AS SHOWN ON THE DRAWINGS AND AS INDICATED IN

THESE SPECIFICATIONS. ALL ELECTRICAL POWERED EQUIPMENT

SHALL BE U.L. LISTED.

WATER SUPPLY SYSTEM:

EXTEND WATER SERVICE AS INDICATED ON DESIGN DRAWINGS.

PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE

REQUIRED.

PIPE AND FITTINGS ABOVE GROUND - TYPE L HARD COPPER AND

WROUGHT COPPER FITTINGS, WITH SOLDERED JOINTS (USE ONLY

"LEAD FREE" SOLDER)..

PIPE AND FITTINGS BELOW GROUND - TYPE "K" SOFT COPPER.

PROVIDE POLYBUTYLENE WRAPPING.

VALVES (3 INCH AND LARGER) - GATES VALVES - ALL BRONZE,

RISING STEM, DOUBLE WEDGE TAPER SEAT, 125 PSI STEAM

PRESSURE.

VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 400 PSI WSP FULL

PORT BRONZE BODY BALL VALVE WITH THREADED ENDS,

LOCKABLE LEVER HANDLE AND REPLACEABLE TEFLON OR TFE

SEATS.

CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER

DISTRIBUTION SYSTEMS SHALL BE STERILIZED WITH CHLORINE IN

ACCORDANCE WITH PLUMBING CODE AND AWWA C-651 OR C-652

STANDARD PROCEDURE FOR DISINFECTING WATER MAINS.

DRAINAGE SYSTEM:

EXTEND PIPING FROM NEW FIXTURES AND EQUIPMENT AND

CONNECT TO SYSTEMS AS INDICATED ON THE DRAWINGS.

PIPE SLOPE:

2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH SLOPE

OF NOT LESS THAN 1/4 INCH PER FOOT.

3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A SLOPE

NOT LESS THAN 1/8 INCH PER FOOT.

PIPE AND FITTINGS:

ABOVE GRADE:

SCHEDULE 40 PVC, DWV COPPER, OR SERVICE WEIGHT CAST IRON

DRAIN, WASTE AND VENT PIPING LOCATED IN FIRE RATED WALL

ASSEMBLIES AND RETURN AIR PLENUMS SHALL BE SERVICE-

WEIGHT CAST IRON WITH SPIGOT FITTINGS OR HUBLESS SOIL PIPE

COUPLINGS AS MANUFACTURED BY MISSION (HW), HUSKEY OR

CLAMPALL (125# OF TORQUE).

BELOW GRADE:

SCHEDULE 40 PVC OR SERVICE WEIGHT CAST IRON WITH HUB AND

SPIGOT FITTINGS OR HUBLESS SOIL PIPE COUPLINGS AS

MANUFACTURED BY MISSION (HW), HUSKEY OR CLAMPALL (125# OF

TORQUE).

PROVIDE CLEANOUTS EVERY 100 FEET, AT CHANGES IN

DIRECTION, AT BASE OF DOWNSPOUTS AND AT BASE OF SOIL AND

WASTE STACKS.

SHOCK ARRESTOR: MIFAB, SIOUX CHIEF OR EQUAL

WALL CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL

FLOOR CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL

VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING. AIR

ADMITTANCE VALVES ARE NOT ACCEPTABLE.

CONNECTIONS TO MISCELLANEOUS EQUIPMENT:

ROUGH-IN AND CONNECT WATER, WASTE, AND VENT TO

COMPLETE THE INSTALLATION OF EQUIPMENT LISTED ON THE

DRAWINGS.

PLUMBING FIXTURES SHALL BE PROVIDED COMPLETE AS SHOWN

ON THE DRAWINGS WITH ALL REQUIRED SUPPLY, WASTE, SOIL,

AND VENT CONNECTIONS, TOGETHER WITH ALL FITTINGS,

SUPPORTS, FASTENING DEVICES, COCKS, VALVES AND TRAPS.

ALL FIXTURES SHALL HAVE STOP VALVES ON ALL WATER

CONNECTIONS. ALL EXPOSED METAL TRIM ON ALL FIXTURES SHALL

BE POLISHED CHROMIUM PLATED.

ALL EXPOSED PIPES EXTENDING FROM WALL SHALL HAVE

CHROMIUM PLATED BRASS ESCUTCHEON MOUNTED AGAINST

WALL. EXPOSED PVC PIPING AND P-TRAPS ARE UNACCEPTABLE.

THE PLUMBING FIXTURES SHALL BE ROUGHED-IN ACCORDANCE

WITH MANUFACTURER'S "ROUGH-IN INFORMATION". PROVISIONS

FOR MOUNTING WALL FIXTURES SHALL BE MADE WHILE THE WALL

IS BEING BUILT. PROVIDE ADDITIONAL BLOCKING, HANGERS, AND

SUPPORTS AS REQUIRED.

INSULATION:

SHALL BE AS MANUFACTURED BY OWENS-CORNING, MANVILLE,

PITTSBURGH CORNING, ARMSTRONG, OR APPROVED EQUAL.

INSULATION SUNDRIES AND ADHESIVES SHALL BE AS

MANUFACTURED BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR

APPROVED EQUAL. ALL INSULATION SHALL BE SUITABLE FOR

INSTALLATION IN A RETURN AIR PLENUM.

INSULATE ALL HOT WATER AND HOT WATER RECIRCULATION LINES

WITH MANVILLE MICROLOCK INSULATION WITH ALL SERVICE

JACKETS. THE MINIMUM INSULATION THICKNESS SHALL BE AS

FOLLOWS:

- FOR PIPES UP TO 2" SHALL BE 1" THICK

- FOR PIPES 2.5 AND GREATER SHALL BE 1.5" THICK

- FOR PIPING RUNOUTS (NOT EXCEEDING 12FT.) SHALL BE .5" THICK

IN LIEU OF FIBERGLASS INSULATION SPECIFIED ABOVE THE

CONTRACTOR HAS THE OPTION TO USE AN EQUAL THICKNESS OF

FLEXIBLE CLOSED-FOAM INSULATION (ARMAFLEX AP) OR EQUAL

WITH SELF SEAL SEAMS. INSULATION TO BE RATED FOR USE IN

RETURN AIR PLENUM (FLAME SPREAD RATING OF 25 OR LESS AND

SMOKE DEVELOPED RATING OF 50 OR LESS PER ASTM E-84).

CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND

INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE-

SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE

ACCUMULATION OF ANY OBJECTIONABLE MOISTURE ON THE

EXTERIOR CONDENSATE DRAIN OR STORM WATER PIPING. OR

OTHER PARTS OF THE SYSTEM. CONTRACTOR SHALL CORRECT THE

CAUSE OF ANY CONDENSATION AND WITHOUT COST TO THE

OWNER, ANY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR

EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR

THE FULL PERIOD OF THE GUARANTEE.

HANGERS AND SUPPORTS:

PROVIDE ALL NECESSARY PIPE SUPPORTS, HANGER RODS, CLAMPS

AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT PIPING

AND EQUIPMENT FROM THE BUILDING STRUCTURE.

PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS

REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK.

ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED,

PRIMED AND PAINTED TO PREVENT RUSTING. FINISH COLOR AS

SELECTED BY OWNER.

THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS

NOT ACCEPTABLE FOR SUPPORTS.

WARRANTY/GUARANTEE:

THE CONTRACTOR SHALL

WARRANTY/GUARANTEE AND MAINTAIN THE

STABILITY OF WORK AND MATERIALS AND KEEP

SAME IN PERFECT REPAIR AND CONDITION FOR

THE ENTIRE DURATION OF PROJECT.

DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS

APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE

IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN

EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND

ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND

REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR

FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL

DEFECT OR REPAIRS THERE TO.

SYSTEM IDENTIFICATION:

PROVIDE IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF

MAJOR EQUIPMENT AND EACH OPERATIONAL DEVICE AND

DISCONNECT. THE LABELS SHALL BE CONSTRUCTED OF

ENGRAVED PLASTIC LAMINATE SIGN OR PLASTIC EQUIPMENT

MARKER PERMANENTLY SECURED TO EQUIPMENT. THE

LETTERING SHALL BE A MINIMUM OF 1/2 INCH HIGH FOR

EQUIPMENT NAME AND 3/8 INCH FOR EQUIPMENT INFORMATION.

ALL VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS

AND SECURED WITH BRASS CHAINS. THE TAGS SHALL INDICATE

THE VALVE SIZE, SERVICE AND FUNCTION (IE. 2" CW., MAIN

SERVICE SHUTOFF).

CLEANING, TESTING AND ADJUSTING:

THE PLUMBING CONTRACTOR, AT THIER EXPENSE, SHALL CLEAN,

REPAIR, ADJUST, CHECK, BALANCE, AND PLACE IN SERVICE THE

VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE

EQUIPMENT, ACCESSORIES AND PIPING. THE PLUMBING

CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS,

EQUIPMENT, AND TOOLS REQUIRED TO PERFORM TESTS

REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING

AUTHORITIES.

NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY

INSPECTED AND TESTED.

TESTING:

ALL DOMESTIC WATER PIPING SYSTEMS SHALL BE TESTED FOR

ABSOLUTE TIGHTNESS BY SUBJECTING THE SYSTEM TO

HYDROSTATIC PRESSURE OF 150 PSI GAUGE OR 50 PSI OVER

WORKING PRESSURE, WHICHEVER IS HIGHER FOR A PERIOD OF

NOT LESS THAN EIGHT (8) HOURS. ALL LEAKS SHALL BE REPAIRED

AND THE HYDROSTATIC TEST REAPPLIED UNTIL, FOR AN EIGHT (8)

HOUR PERIOD, NO LEAKS CAN BE FOUND WHILE THE SYSTEM IS

SUBJECT TO THE TEST PRESSURE.

SOIL, VENT PIPES AND CONDENSATE DRAINS SHALL BE TESTED BY

TEMPORARILY PLUGGING ALL OUTLETS AND FILLING THE SYSTEM

WITH WATER TO THE LEVEL OF THE HIGHEST VENT STACK. THE

SYSTEM MUST BE INSPECTED AND ALL LEAKS REPAIRED AND THE

TEST REPEATED UNTIL THE WATER LEVEL DOES NOT DECREASE

FOR A PERIOD OF 24 HOURS.

WATER HAMMER ARRESTOR

SYMBOL

1/2"

PIPE SIZE PDI STANDARD FIXTURE UNIT CAP.

3/4"

1"

1-1/4"

A

B

C

D

1 TO 11

12 TO 32

33 TO 60

61 TO 113

NOT TO SCALE

DATE

SHEET NO.

SCALE:

REVISION/ SUBMISSIONS

SHT. TITLE

SEAL

NO.

AG PROJECT:

COMMISSION NO.

DRAWN:

CHECKED:

DATE:

PH (386) 255-6163208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

RESTROOM RENOVATIONS

DAYTONA BEACH, FLORIDA

207 DR. MARY McLEOD BETHUNE BLVD.

VOTRAN TRANSFER PLAZA

HALL &

ARCHITECT

20-NOV.-2025

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

P-001

PLUMBING LEGENDS, SYMBOLS, & SPECS

AJZ

KJDD

A

N

IE

L G

LO

V

E R

, P .E

F

L Li ce ns e

0121022

SHEET LIST

Sheet Number Sheet Name

P-001 PLUMBING LEGENDS, SYMBOLS, & SPECS

PD111 PLUMBING FLOOR PLANS - DEMO

P-111 PLUMBING FLOOR PLANS - NEW

P-301 PLUMBING DETAILS & SCHEDULES

David Text Box

28-JULY-2025

WOMEN'S

MEN'S

WOMEN'S

MEN'S

WOMEN'S

MEN'S

WOMEN'S

MEN'S

(E)4" FD

(E)4" FD

(E)LAV

(E)SK

(E)LAV

(E)WCO

(E)WCO

(E)WC (E)WC

(E)LAV (E)LAV

(E)WC

(E)LAV

(E)UR

2 2

2 2

(E)4" S

(E)4" S (E)2 1/2" V

(E)1 1/4" V(E)2" V

(E)2" V (E)2 1/2" V (E)2" V (E)1 1/2" V

(E)1 1/4" V

(E)1" CW (E)1 1/4" CW

(E)1 1/2" CW

(E)1/2" HW

(E)2" CW

(E)3/4" HW

(E)1 1/2" CW

(E)3/4" HW

(E)1/2" HW

(E)1/2" CW

(E)3/4" CW

(E)1/2" HW(E)1/2" HW

(E)1 1/2" CW(E)1 1/4" CW(E)1" CW

(E)SK

(E)LAV

(E)LAV

(E)WC (E)WC

(E)LAV (E)LAV

(E)WC

(E)LAV

(E)UR

2 2

2 2

(E)2" CW & 3/4" HW BACK TO

WATER HEATER LOCATED

IN JANITOR'S CLOSET

DATE

SHEET NO.

SCALE:

REVISION/ SUBMISSIONS

SHT. TITLE

SEAL

NO.

AG PROJECT:

COMMISSION NO.

DRAWN:

CHECKED:

DATE:

PH (386) 255-6163208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

RESTROOM RENOVATIONS

DAYTONA BEACH, FLORIDA

207 DR. MARY McLEOD BETHUNE BLVD.

VOTRAN TRANSFER PLAZA

HALL &

ARCHITECT

20-NOV.-2025

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

1/2" = 1'-0"

PD111

PLUMBING FLOOR PLANS - DEMO

AJZ

KJDD

A

N

IE

L G

LO

V

E R

, P .E

F

L Li ce ns e

0121022

1/2" = 1'-0"PD111

1 PLUMBING SANITARY FLOOR PLAN - DEMO

1/2" = 1'-0"PD111

3 PLUMBING DOMESTIC WATER FLOOR PLAN - DEMO

DRAWING NOTES:

1. EXISTING TILE WALL TO REMAIN AND SHALL NOT BE DISTURBED.

2. ALL EXISTING PIPING SHALL REMAIN. IF ANY EXISTING PIPING PENETRATING WALLS IS REQUIRED TO

BE REMOVED FOR CONNECTION TO NEW FIXTURES, A COVER PLATE SHALL BE PROVIDED.

CODED NOTES:

REMOVE AND REPLACE EXISTING GRATE ON FLOOR DRAIN. CLEAN FLOOR DRAIN PRIOR TO

INSTALLATION OF NEW GRATE.

DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. PREPARE PIPE CONNECTIONS FOR NEW FIXTURE.

DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. REMOVE SANITARY AND VENT PIPING BACK TO

POINT INDICATED AND CAP.

DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. REMOVE PRESSURE PIPING BACK TO POINT

INDICATED AND CAP.

0 1' 2' 4' 6'

1/2" = 1'-0" N

David

MEN'S

VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N

VITREOUS CHINA BATHROOM SINK CAXTON K-2210-N

WOMEN'S

MEN'S

VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N

VITREOUS CHINA BATHROOM SINK CAXTON K-2210-N

(E)4" S

(E)4" S

(E)SK

(E)2 1/2" V

(E)1 1/4" V(E)2" V

(E)2" V (E)2 1/2" V (E)2" V (E)1 1/2" V

(E)1 1/4" V

(E)WCO

(E)WCO

L-1 L-1

L-1

(E)4" FD-1

(E)4" FD-11

2 2

WC-1

U-15

WC-15 WC-15

(E)1/2" HW

(E)SK

(E)1" CW (E)1 1/4" CW

(E)1 1/2" CW

(E)1/2" HW

(E)2" CW

(E)3/4" HW

(E)1 1/2" CW

(E)3/4" HW

(E)1/2" CW

(E)3/4" CW

(E)1/2" HW(E)1/2" HW

(E)1 1/2" CW(E)1 1/4" CW(E)1" CW

L-1

WC-1

U-1

3 L-13

L-13

WC-14 WC-14

DATE

SHEET NO.

SCALE:

REVISION/ SUBMISSIONS

SHT. TITLE

SEAL

NO.

AG PROJECT:

COMMISSION NO.

DRAWN:

CHECKED:

DATE:

PH (386) 255-6163208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

RESTROOM RENOVATIONS

DAYTONA BEACH, FLORIDA

207 DR. MARY McLEOD BETHUNE BLVD.

VOTRAN TRANSFER PLAZA

HALL &

ARCHITECT

20-NOV.-2025

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

1/2" = 1'-0"

P-111

PLUMBING FLOOR PLANS - NEW

AJZ

KJDD

A

N

IE

L G

LO

V

E R

, P .E

F

L Li ce ns e

0121022

1/2" = 1'-0"P-111

1 PLUMBING SANITARY FLOOR PLAN - NEW

1/2" = 1'-0"P-111

2 PLUMBING DOMESTIC WATER FLOOR PLAN - NEW

DRAWING NOTES:

1. EXISTING TILE WALL TO REMAIN AND SHALL NOT BE DISTURBED.

2. EXISTING WATER SUPPLY AND SANITARY CONNECTION LOCATIONS SHALL REMAIN. NEW FIXTURES

SHALL CONNECT TO EXISTING WATER SUPPLY AND SANITARY CONNECTIONS.

CODED NOTES:

REFER TO CODED NOTE 1 / PD111.

ADJUST/REPLACE P-TRAP AS REQUIRED TO LINE UP WITH NEW LAVATORY DRAIN.

CONNECT (E)1/2" CW & HW TO ZURN ZW1070XL THERMOSTATIC MIXING VALVE MOUNTED UNDER THE

COUNTER/LAV. ROUTE 1/2" TEMPERED WATER TO LAV.

CONNECT UR/WC TO (E)CW.

CONNECT UR/WC TO (E)SANITARY

0 1' 2' 4' 6'

1/2" = 1'-0"

N

David

EXISTING WATER

SUPPLY

WATER CLOSET

SOLID RING PIPE SUPPORT (2 REQUIRED)

GRAB BAR (BY OTHERS)

FLUSH VALVE

FINISHED WALL

WATER CONNECTION TO

MATCH EXISTING

LOCATION AND HEIGHT

BATTERY POWERED SENSOR

FAUCET. REFER TO SCHEDULE

FOR FAUCET TYPE

LAVATORY

SUPPLY ANGLE

STOP (TYP)

1/2" CW SUPPLY

1/2" HW SUPPLY

95°F (ADJUSTABLE)

TEMPERED WATER

ASSE 1070

THERMOSTATIC

MIXING VALVE

ELECTRONICS

MODULE

NOT TO SCALE

DATE

SHEET NO.

SCALE:

REVISION/ SUBMISSIONS

SHT. TITLE

SEAL

NO.

AG PROJECT:

COMMISSION NO.

DRAWN:

CHECKED:

DATE:

PH (386) 255-6163208 MAGNOLIA AVENUE

DAYTONA BEACH, FLORIDA 32114

AA-C000925

FAX (386)257-5650

www.hoarchitects.com

RESTROOM RENOVATIONS

DAYTONA BEACH, FLORIDA

207 DR. MARY McLEOD BETHUNE BLVD.

VOTRAN TRANSFER PLAZA

HALL &

ARCHITECT

20-NOV.-2025

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

P-301

PLUMBING DETAILS & SCHEDULES

AJZ

KJDD

A

N

IE

L G

LO

V

E R

, P .E

F

L Li ce ns e

0121022

N.T.S.

WATER CLOSET, FLOOR MOUNTED DETAIL

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE MANUFACTURER MODEL NO. TYPE MATERIAL WASTE VENT CW HW REMARKS

L-1 LAVATORY

(ADA ACCESSIABLE)

AMERICAN

STANDARD

0491.019 DROP IN VITREOUS

CHINA

1-1/2" 2" 1/2" 1/2" 19-1/8” ROUND VITREOUS CHINA, SELF-RIMMING, COUNTERTOP LAVATORY WITH 4" CENTER

HOLES. FRONT OVERFLOW DESIGN. WASTE: 1-1/4" O.D. FAUCET: HYDROTEK 5000E BATTERY

POWERED FAUCET WITH OPTIONAL 4" CENTER HOLE COVER PLATE. GRID DRAIN: MCGUIRE

PRODRAIN – OFFSET GRID DRAIN FOR WHEEL CHAIR ACCESSIBILITY. PTRAP: ZURN Z8700-8B-PC.

TRAP WRAP: Z8946-1-NT. SUPPLY: MCGUIRE 2165CC. MIXING VALVE: ZURN ZW1070XL.

U-1 URINAL

(ADA ACCESSIBLE)

AMERICAN

STANDARD

6590.001 FLUSH VALVE

WALL MOUNT

VITREOUS

CHINA

3" 2" 1" - WALL MOUNTED URINAL, VITREOUS CHINA, HIGH EFFICIENCY URINAL, 1.0 GPF, 3/4" TOP SPUD, WITH VACUUM BREAKER AND CONTROL STOP. FLUSH VALVE: SLOAN ROYAL 180-1.0. SENSOR:

SLOAN EBV-200-A (BATTERY). INSTALL URINAL AT HEIGHT TO MATCH EXISTING WATER

CONNECTION TO FLUSH VALVE. MAX ADA HEIGHT IS 17” AFF. CARRIER: Z1221.

WC-1 WATER CLOSET

(ADA ACCESSIBLE)

AMERICAN

STANDARD

3043.001 FLUSH VALVE

FLOOR MOUNT

VITREOUS

CHINA

4" 2" 1-1/4" - FLOOR MOUNTED TOILET AT ADA HEIGHT, VITREOUS CHINA, 1.6 GPF WITH SIPHON JET FLUSHING

ACTION. ELONGATED FRONT RIM, AND 1-1/2" TOP SPUD CONNECTION. SEAT: AMERICAN

STANDARD 5901.100. FLUSH VALVE: SLOAN-REGAL 111-1.6. SENSOR: SLOAN EBV-200-A (BATTERY).

N.T.S.

SENSOR FAUCET DETAIL

David

-ELECTRIC DUCT HEATER (W/PANEL

CLEARANCE)

-MANUAL BALANCING DAMPER

-MOTOR OPERATED CONTROL DAMPER

(MOD)

-FLEXIBLE CONNECTION

-ACCESS DOORS, VERTICAL OR HORIZONTAL

-DOOR GRILLE

-UNDERCUT DOOR

-SPIN-IN TAKE-OFF

-DUCT ELBOW UP THROUGH ROOF OR SLAB

ABOVE

-RECTANGLE-TO-ROUND TAKE-OFF

DNUP

-TRANSITION, SQUARE TO ROUND

-CEILING EXHAUST

-CEILING RETURN

-STANDARD BRANCH TAKE-OFF

-RADIUS ELBOW

-TRANSITION, ECCENTRIC

-FLEXIBLE DUCT

-CHANGE OF ELEVATION

-DUCT ELBOW, NEGATIVE PRESSURE,

RETURN

-DUCT ELBOW, EXHAUST

-DUCT ELBOW, POSITIVE PRESSURE

(SUPPLY)

-NEW DUCTWORK, FIRST DIMENSION IS SIDE

SHOWN

-TRANSITION, CONCENTRIC

-SQUARE THROAT ELBOW

W/TURNING VANES

-RECTANGULAR/ROUND BRANCH TAKE-

OFF

OR ROUND/ROUND BRANCH TAKE-OFF

-SQUARE THROAT TEE

-RADIUS TEE

-SUPPLY REGISTER OR GRILLE

-RETURN/EXHAUST REGISTER OR GRILLE

(VERTICAL MOUNT, SIDEWALL)

(VERTICAL MOUNT, SIDEWALL)

-CEILING DIFFUSER, ROUND NECK

(CEILING DIFFUSERS ARE 4-WAY THROW UNO)

-CEILING DIFFUSER, RECTANGULAR OR

SQUARE NECK (CEILING DIFFUSERS

ARE 4-WAY THROW UNO)

-TEMPERATURE SENSOR

-MOTORIZED CONTROL DAMPER

-HUMIDISTAT/HUMIDITY SENSOR

-THERMOSTAT/TEMPERATURE SENSOR

-REVISION REFERENCE

-DETAIL REFERENCE: TOP - DETAIL#;

BOTTOM - DRAWING# SHOWN ON

-STATIC PRESSURE SENSOR

-DUCT SMOKE DETECTOR

FF -FINAL FILTERS

DDC -DIRECT DIGITAL CONTROLS

PRS -PRESSURE REDUCING STATION

SP -STATIC PRESSURE

-CFM (CUBIC FEET PER MINUTE)

P -CHANGE IN PRESSURE

CV -CONSTANT AIR VOLUME

-ROOFTOP AIR HANDLING UNITRTU

RS/L -REFRIGERANT SUCTION & LIQUID LINES

C -OUTSIDE AIR LOUVEROAL

-VARIABLE AIR VOLUMEVAV

-SUPPLY AIRSA

-ROOFTOP HEAT PUMPRHP

-REHEAT COILRHC

-REVOLUTIONS PER MINUTERPM

-RETURN AIRRA

-POLYVINYL CHLORIDE PIPEPVC

-PSI GAUGEPSIG

-POUNDS PER SQUARE INCHPSI

-PRESSURE REDUCING VALVEPRV

-OUTSIDE AIROA

-NOT TO SCALENTS

-NORMALLY OPENNO

-NORMALLY CLOSEDNC

-LINEAR DIFFUSERLD

-LEAVING WATER TEMPERATURELWT

-LEAVING AIR TEMPERATURELAT

-GALLONS PER MINUTEGPM

-FEET PER MINUTE

-FIRE DAMPER

-FAN COIL UNIT

-ENTERING WATER TEMPERATURE

-ENTERING AIR TEMPERATURE

-DOWN

-CONDENSING UNIT

-CUBIC FEET PER MINUTE

-CHANGE IN TEMPERATURE

-COOLING TOWER

-CONDENSATE

-CENTER LINE

-BRITISH THERMAL UNIT

-BRAKE HORSEPOWER

-BOTTOM OF PIPE

-ACCESS PANEL

-ABOVE FINISHED FLOOR

FPM

FD

FCU

EWT

EAT

DN

CU

CFM

T

CT

CD

BTU

BOP

BHP

AP

AFF

-AIR HANDLING UNITAHU

MBH -THOUSAND BTUs PER HOUR

ESP -EXTERNAL STATIC PRESSURE

KW -KILOWATT

MCA -MINIMUM CIRCUIT AMPS

MOCP -MAXIMUM OVER CURRENT PROTECTION

UNO

TSP -TOTAL STATIC PRESSURE

-VOLTS/PHASEV/PH

VFD -VARIABLE FREQUENCY DRIVE

-UNLESS NOTED OTHERWISE

FLA -FULL LOAD AMPS

NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT

HVAC ABBREVIATIONSHVAC SYMBOL LEGEND

-BACKDRAFT DAMPER

MOD -MOTOR OPERATED CONTROL DAMPER (MOD)

-PACKAGED TERMINAL AIR CONDITIONERPTAC

-SHEET NOTE CALLOUT

-CEILING MOUNTED ACCESS DOOR

-RECTANGULAR DUCT SECTION UP,

EXHAUST

-RECTANGULAR DUCT SECTION UP,

NEGATIVE PRESSURE, RETURN

-RECTANGULAR DUCT SECTION UP, POSITIVE

PRESSURE,

SUPPLY OR OUTSIDE AIR

-ROUND DUCT SECTION UP

SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

-ABOVE FINISHED ROOFAFR

-BUTTERFLY VALVEBFV

c

T

H

DOWN UP W/IN FLOOR

UC

M-1

XX

XX

M

T

SP

BD

M

L

VRF -VARIABLE REFRIGERANT FLOW

-EXHAUST AIREA

-CLEAN OUTCO

-CONNECT TO EXISTING

-DEMOLISH TO POINT INDICATED

-FIRE & SMOKE DAMPER

(WITH ACCESS PANEL)

-FIRE DAMPER (WITH ACCESS PANEL)

-HUMIDITY SENSOR (DUCT MOUNTED)H

-CARBON DIOXIDE SENSOR (DUCT MOUNTED)CO2

-CARBON DIOXIDE SENSORCO2

1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.

TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.

2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR

FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH

AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO

OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST.

3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC

DUCT CONSTRUCTION STANDARD.

4. INSTALL ALL FIRE DAMPERS, SMOKE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS IN

ACCORDANCE WITH MANUFACTURE'S INSTALLATION DIRECTIONS. PROVIDE ACCESS DOORS TO

ALLOW COMPLETE INSPECTION AND MAINTENANCE OF ALL DEVICES.

5. PROVIDE 1.5R ELBOWS IN DUCTWORK AS INDICATED. IF 1.5R ELBOWS DO NOT FIT, PROVIDE 1.0R ELBOWS. IF 1.0R ELBOWS DO NOT FIT, PROVIDE 90 DEGREE RECTANGULAR DUCT ELBOWS WITH

TURNING VANES.

6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT

FURNISHED.

7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED

CEILING PLANS AND EQUIPMENT OF ALL TRADES.

8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48"

ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER

EQUIPMENT, FURNITURE, AND DOOR SWINGS.

9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE

ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.

10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.

11. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.

MECHANICAL EQUIPMENT TAGS

12. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR

PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED.

13. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR

OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.

14. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO

FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.

15. COORDINATE SIZE REQUIREMENTS OF ALL CONCRETE HOUSEKEEPING PADS UNDER ALL FLOOR-

MOUNTED EQUIPMENT. SEE STRUCTURAL DRAWINGS FOR PAD DETAILS AND SPECIFICATIONS.

16. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS

AND OTHER AIR DISTRIBUTION DEVICES.

17. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO FANS, AIR HANDLING

UNITS, AND FAN COIL UNITS.

18. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE

CONNECTED.

19. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS.

20. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.

21. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 10'-0" CLEAR FROM ALL PLUMBING VENTS AND EXHAUST AIR DISCHARGE LOCATIONS. LOWEST POINT OF EACH OUTSIDE AIR INTAKE ON ROOF SHALL

BE A MINIMUM OF 24" ABOVE ROOF.

22. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.

23. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED

FULL SIZE TO THE NEAREST PLUMBING DRAIN.

GENERAL NOTES

-AIR HANDLING UNIT

-AIR DISTRIBUTION DEVICE

AHU-1

VTU-1-1

-ELECTRIC DUCT HEATEREDH-1-1

CFM

SIZE TYPE

SSR - SUPPLY

SRR - RETURN

12x6 SSR

300 CFM

OAV - OUTSIDE AIR VALVE

AHU

NUMBER HEATER NUMBER

TAG

CFM

VTU - VARIABLE TERMINAL UNIT

TERMINAL UNIT TYPE

TERMINAL NUMBER

AHU/OAU NUMBER

AHU NUMBER

45145

BASIC MATERIALS

EXISTING TO BE REMOVED (HEAVY, DASHED LINE)

EX…