This document constitutes the complete construction plans for the Votran Transfer Plaza Restroom Renovations project located at 207 Dr. Mary McLeod Bethune Boulevard in Daytona Beach, Florida. The project involves a comprehensive renovation of two employee restrooms (Men's Room 106 and Women's Room 107) adjacent to the break room at the VOTRAN transit facility. The renovation scope includes demolition of existing plumbing fixtures, toilet partitions, vanities, and finishes; installation of new ADA-compliant fixtures including water closets, lavatories, and urinals; replacement of flooring with 12-inch by 12-inch porcelain ceramic tile; installation of fiberglass reinforced panels over existing mosaic tile walls; new lighting fixtures with occupancy sensors; replacement of the exhaust fan system; and installation of new ceiling tiles and accessories. The construction documents are dated July 28, 2025, and were prepared by Hall & Ogle Architects, Inc. under project number PC2868 with architect David D. Ogle (FL License AR93986). The plans encompass architectural, plumbing, mechanical, and electrical design drawings with detailed specifications and schedules organized across multiple sheets including demolition plans, floor plans, elevations, details, and finish schedules.
All construction work must comply with the 2023 Florida Building Code (Eighth Edition) in all applicable divisions, the 2023 NFPA National Electric Code, and the 2023 Florida Fire Prevention Code. The project requires coordination among multiple trades including plumbing, HVAC, electrical, and general construction. Plumbing specifications call for Type L hard copper above ground with soldered lead-free joints, new fixtures with ADA-compliant mounting heights and grab bars, thermostatic mixing valves for water temperature control, and comprehensive testing at 150 PSI. Mechanical work includes replacement of the rooftop exhaust fan (Greenheck G-100-VG, 590 CFM) with connection to existing ductwork and controls, new supply and exhaust grilles, and balancing to specified airflow rates. Electrical work includes new lighting with LED fixtures and occupancy/vacancy sensors with 30-minute timeout settings, replacement of hand dryers, GFCI receptacles, and emergency lighting as required. All work must be performed in phases to maintain employee break room functionality, with careful coordination of temporary closures and staging areas to minimize operational disruption.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP
PROJECT SITE AREA OF WORK
AERIAL VIEW STREET VIEW
DAYTONA BEACH, FLORIDA
VOTRAN TRANSFER PLAZA
RESTROOM RENOVATIONS
HALL & OGLE
ARCHITECTS, INC.
PH (386) 255-6163 208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
JULY 28, 2025100% CONSTRUCTION DOCUMENTS
SCHEDULE OF DRAWINGS
VC PROJECT NO. PC2868
GENERAL NOTES
AutoCAD SHX Text
CS
AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REVISION/ SUBMISSIONS
AutoCAD SHX Text
SHT. TITLE
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
PROJECT ARCH:
AutoCAD SHX Text
COMMISSION NO.
AutoCAD SHX Text
DAVID D. OGLE AR93986
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DO
AutoCAD SHX Text
DO
AutoCAD SHX Text
RESTROOM RENOVATIONS
AutoCAD SHX Text
28-JULY-2025
AutoCAD SHX Text
DAYTONA BEACH, FLORIDA
AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.
AutoCAD SHX Text
VOTRAN TRANSFER PLAZA
AutoCAD SHX Text
SC/DO
AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114
AutoCAD SHX Text 207 Dr. Mary McLeod Bethune Blvd. Daytona Beach, FL 32114
AutoCAD SHX Text
COVER SHEET / SCHEDULE OF DRAWINGS
AutoCAD SHX Text
CS
AutoCAD SHX Text A2.0
AutoCAD SHX Text
FLOOR PLAN / REFLECTED CEILING PLAN
AutoCAD SHX Text D2.0
AutoCAD SHX Text
DEMOLITON PLANS
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
PD111
AutoCAD SHX Text
PLUMBING FLOOR PLANS - DEMO
AutoCAD SHX Text P-001
AutoCAD SHX Text
PLUMBING LEGENDS, SYMBOLS, & SPECS
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text M-002
AutoCAD SHX Text
MECHANICAL SPECIFICATIONS
AutoCAD SHX Text M-001
AutoCAD SHX Text
MECHANICAL LEGENDS, SYMBOLS, & GENERAL NOTES
AutoCAD SHX Text M-111
AutoCAD SHX Text
MECHANICAL FLOOR PLANS
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text E-002
AutoCAD SHX Text
ELECTRICAL GENERAL NOTES
AutoCAD SHX Text E-001
AutoCAD SHX Text
ELECTRICAL LEGENDS & SYMBOLS
AutoCAD SHX Text E-003
AutoCAD SHX Text
ELECTRICAL SPECIFICATIONS
AutoCAD SHX Text E-101
AutoCAD SHX Text
ELECTRICAL FLOOR PLANS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text P-111
AutoCAD SHX Text
PLUMBING FLOOR PLANS - NEW
AutoCAD SHX Text P-301
AutoCAD SHX Text
PLUMBING DETAILS
AutoCAD SHX Text A2.1
AutoCAD SHX Text
ELEVATIONS AND DETAILS
AutoCAD SHX Text
ALL CONSTRUCTION TO CONFORM AS APPLICABLE TO THE FOLLOWING CODES:
AutoCAD SHX Text
NFPA NATIONAL ELECTRIC CODE (2023)
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) BUILDING
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) ACCESSIBILITY
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) FBC ENERGY CONSERVATION
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) FUEL GAS
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) MECHANICAL
AutoCAD SHX Text
FLORIDA BUILDING CODE: - EIGHTH EDITION (2023) PLUMBING
AutoCAD SHX Text
FLORIDA FIRE PREVENTION CODE - EIGHTH EDITION (2023)
HALL & OGLE
ARCHITECTS, INC.
PH (386) 255-6163 208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: \"= 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REVISION/ SUBMISSIONS
AutoCAD SHX Text
SHT. TITLE
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
PROJECT ARCH:
AutoCAD SHX Text
COMMISSION NO.
AutoCAD SHX Text
DAVID D. OGLE AR93986
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DO
AutoCAD SHX Text
DO
AutoCAD SHX Text
RESTROOM RENOVATIONS
AutoCAD SHX Text
28-JULY-2025
AutoCAD SHX Text
DAYTONA BEACH, FLORIDA
AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.
AutoCAD SHX Text
VOTRAN TRANSFER PLAZA
AutoCAD SHX Text
SC/DO
AutoCAD SHX Text
DEMOLITION FLOOR PLAN
AutoCAD SHX Text D2.0
AutoCAD SHX Text
DEMOLITION PLANS
AutoCAD SHX Text
DEMOLITION NOTES:
AutoCAD SHX Text
1. REMOVE ALL EXISTING PLUMBING FIXTURES 2. REMOVE EXISTING TOILET PARTITIONS 3. REMOVE EXISTING VANITIES 4. REMOVE ALL TILE FLOORING (COVE BASE TO REMAIN) 5. REMOVE PORTION OF GYP. BD. SOFFIT 6. REMOVE ALL EXISTING TOILET ACCESSORIES 7. REMOVE PORTION OF EXISTING STUD WALL 8. REMOVE EXISTING CEILING TILES, GRID TO REMAIN
AutoCAD SHX Text
SCALE: \"= 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
DEMOLITION REFLECTED CEILING PLAN
AutoCAD SHX Text
NOTE 5
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 3
AutoCAD SHX Text
NOTE 3
AutoCAD SHX Text
NOTE 6
AutoCAD SHX Text
NOTE 6
AutoCAD SHX Text
NOTE 7
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
NOTE 8
AutoCAD SHX Text
NOTE 8
AutoCAD SHX Text
NOTE 4
NOTE 4
PH (386) 255-6163 208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: \"= 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REVISION/ SUBMISSIONS
AutoCAD SHX Text
SHT. TITLE
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
PROJECT ARCH:
AutoCAD SHX Text
COMMISSION NO.
AutoCAD SHX Text
DAVID D. OGLE AR93986
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DO
AutoCAD SHX Text
DO
AutoCAD SHX Text
RESTROOM RENOVATIONS
AutoCAD SHX Text
28-JULY-2025
AutoCAD SHX Text
DAYTONA BEACH, FLORIDA
AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.
AutoCAD SHX Text
VOTRAN TRANSFER PLAZA
AutoCAD SHX Text
SC/DO
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text A2.0
AutoCAD SHX Text
FLOOR PLAN / REFLECTED CEILING PLAN
AutoCAD SHX Text
SCALE: \"= 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
INFILL ACOUSTICAL CEILING GRID IN THIS AREA
AutoCAD SHX Text REPLACE ALL ACOUSTICAL CEILING TILES W/ USG SHEETROCK BRAND LAY-IN CLIMAPLUS PANELS, ITEM 3260 OR EQUAL
AutoCAD SHX Text
NEW HVAC DEVICES, SEE MECHANICAL DWG'S.
AutoCAD SHX Text
NEW LIGHT FIXTURES, SEE ELECTRICAL DWG'S.
AutoCAD SHX Text
AutoCAD SHX Text A2.2
AutoCAD SHX Text
AutoCAD SHX Text K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A2.2
AutoCAD SHX Text
AutoCAD SHX Text A2.2
AutoCAD SHX Text
TOILET ACCESSORY SCHEDULE
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TOILET AREAS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (36")
AutoCAD SHX Text
MANUFACTURER/MODEL NUMBER
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text
(SM) SOAP DISPENSER
AutoCAD SHX Text
N.I.C. (BY COUNTY)
AutoCAD SHX Text
(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE
AutoCAD SHX Text
BOBRICK B-3699
AutoCAD SHX Text
(SM) TOILET PAPER DISP. (DBL. ROLL)
AutoCAD SHX Text
BOBRICK B-2888
AutoCAD SHX Text G
AutoCAD SHX Text
(SM) SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text
BOBRICK B-254
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text MIRROR (30" x 48")
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (42")
AutoCAD SHX Text B
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text F
AutoCAD SHX Text
BOBRICK B-2908-1836
AutoCAD SHX Text
(SM) MIRROR (18" X 36")
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text
COUNTERTOP PAPER TOWEL DISPENSER
AutoCAD SHX Text
TORK 302030
AutoCAD SHX Text K
AutoCAD SHX Text
DROP-IN TRASH CHUTE
AutoCAD SHX Text
BOBRICK B-529
AutoCAD SHX Text L
AutoCAD SHX Text
ROBE HOOK
AutoCAD SHX Text
BOBRICK B-76717
AutoCAD SHX Text
ACCESSORY SCHEDULE NOTES
AutoCAD SHX Text
N.I.C. TO BE SUPPLIED BY OWNER
AutoCAD SHX Text
AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.
AutoCAD SHX Text
AutoCAD SHX Text
SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.
AutoCAD SHX Text
AutoCAD SHX Text
SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.
AutoCAD SHX Text
TOILET ACCESSORY SCHEDULE
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TOILET AREAS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (36")
AutoCAD SHX Text
MANUFACTURER/MODEL NUMBER
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text
(SM) SOAP DISPENSER
AutoCAD SHX Text
N.I.C. (BY COUNTY)
AutoCAD SHX Text
(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE
AutoCAD SHX Text
BOBRICK B-3699
AutoCAD SHX Text
(SM) TOILET PAPER DISP. (DBL. ROLL)
AutoCAD SHX Text
BOBRICK B-2888
AutoCAD SHX Text G
AutoCAD SHX Text
(SM) SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text
BOBRICK B-254
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text MIRROR (30" x 48")
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (42")
AutoCAD SHX Text B
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text F
AutoCAD SHX Text
BOBRICK B-2908-1836
AutoCAD SHX Text
(SM) MIRROR (18" X 36")
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text
COUNTERTOP PAPER TOWEL DISPENSER
AutoCAD SHX Text
TORK 302030
AutoCAD SHX Text K
AutoCAD SHX Text
DROP-IN TRASH CHUTE
AutoCAD SHX Text
BOBRICK B-529
AutoCAD SHX Text L
AutoCAD SHX Text
ROBE HOOK
AutoCAD SHX Text
BOBRICK B-76717
AutoCAD SHX Text
ACCESSORY SCHEDULE NOTES
AutoCAD SHX Text
N.I.C. TO BE SUPPLIED BY OWNER
AutoCAD SHX Text
AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.
AutoCAD SHX Text
AutoCAD SHX Text
SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.
AutoCAD SHX Text
AutoCAD SHX Text
SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.
AutoCAD SHX Text J
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text NEW 12" X 12" PORCELAIN CERAMIC TILE W/ EPOXY GROUT OVER CRACK ISOLATION MEMBRANE, DALTILE HARMONIST, COLOR AS SELECTED BY OWNER
AutoCAD SHX Text TOILET PARTITIONS TO BE SCRANTON HINY HIDERS 55", FLOOR MOUNTED, OVERHEAD BRACED. COLOR: AS SELECTED (TYP.), INSTALL IN SAME LOCATION AS EXISTING PARTITIONS
AutoCAD SHX Text M
AutoCAD SHX Text
HAND DRYER
AutoCAD SHX Text
XLERATOR OR EQUAL
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
PROVIDE SCHLUTER REDUCER STRIP AT EXISTING FLOORING, RENO-U SATIN FINISH
AutoCAD SHX Text
TERMINATE TILE AT EXISTING DOOR THRESHOLD
ALL INTERIOR WALLS TO RECEIVE FRP PANELS OVER THE EXISTING MOSAIC WALL TILE, FROM THE TOP OF THE COVE BASE TO THE CEILING ABOVE, INCLUDING AROUND THE WINDOW OPENINGS, COLOR TO BE SELECTED BY THE OWNER
PH (386) 255-6163 208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
AutoCAD SHX Text
60" MIN.
AutoCAD SHX Text
48" MIN
AutoCAD SHX Text
30" MIN.
AutoCAD SHX Text
60" DIAM. MIN
AutoCAD SHX Text 2'-9 1/2"
AutoCAD SHX Text
2'-1" COUNTER TOP
AutoCAD SHX Text
2'-0" BASE CABINET
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-8\"
AutoCAD SHX Text 4"
AutoCAD SHX Text 1'-8"
AutoCAD SHX Text 4"
AutoCAD SHX Text
2'-1" COUNTER TOP
AutoCAD SHX Text
2'-0" BASE CABINET
AutoCAD SHX Text 4"
AutoCAD SHX Text 9"
AutoCAD SHX Text 13"
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REVISION/ SUBMISSIONS
AutoCAD SHX Text
SHT. TITLE
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
NO.
AutoCAD SHX Text
PROJECT ARCH:
AutoCAD SHX Text
COMMISSION NO.
AutoCAD SHX Text
DAVID D. OGLE AR93986
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DO
AutoCAD SHX Text
DO
AutoCAD SHX Text
RESTROOM RENOVATIONS
AutoCAD SHX Text
28-JULY-2025
AutoCAD SHX Text
DAYTONA BEACH, FLORIDA
AutoCAD SHX Text 207 DR. MARY McLEOD BETHUNE BLVD.
AutoCAD SHX Text
VOTRAN TRANSFER PLAZA
AutoCAD SHX Text
SC/DO
AutoCAD SHX Text A2.1
AutoCAD SHX Text
ELEVATIONS AND DETAILS
AutoCAD SHX Text
TOILET ACCESSORY SCHEDULE
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TOILET AREAS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (36")
AutoCAD SHX Text
MANUFACTURER/MODEL NUMBER
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text
(SM) SOAP DISPENSER
AutoCAD SHX Text
N.I.C. (BY COUNTY)
AutoCAD SHX Text
(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE
AutoCAD SHX Text
BOBRICK B-3699
AutoCAD SHX Text
(SM) TOILET PAPER DISP. (DBL. ROLL)
AutoCAD SHX Text
BOBRICK B-2888
AutoCAD SHX Text G
AutoCAD SHX Text
(SM) SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text
BOBRICK B-254
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text MIRROR (30" x 48")
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (42")
AutoCAD SHX Text B
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text F
AutoCAD SHX Text
BOBRICK B-2908-1836
AutoCAD SHX Text
(SM) MIRROR (18" X 36")
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text
COUNTERTOP PAPER TOWEL DISPENSER
AutoCAD SHX Text
TORK 302030
AutoCAD SHX Text K
AutoCAD SHX Text
DROP-IN TRASH CHUTE
AutoCAD SHX Text
BOBRICK B-529
AutoCAD SHX Text L
AutoCAD SHX Text
ROBE HOOK
AutoCAD SHX Text
BOBRICK B-76717
AutoCAD SHX Text
ACCESSORY SCHEDULE NOTES
AutoCAD SHX Text
N.I.C. TO BE SUPPLIED BY OWNER
AutoCAD SHX Text
AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.
AutoCAD SHX Text
AutoCAD SHX Text
SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.
AutoCAD SHX Text
AutoCAD SHX Text
SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.
AutoCAD SHX Text
ADA ACCESSIBILITY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
WALL ELEVATION REFERENCE
AutoCAD SHX Text TOILET ROOMS SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR HANDICAPPED ACCESSIBILITY, INCLUDING ALL AMENDMENTS AND REVISIONS TO DATE. MOUNTING HEIGHTS OF FIXTURES AND ACCESSORIES SHALL BE AS FOLLOWS:
AutoCAD SHX Text
WATER CLOSET SEAT HEIGHT - 1'-3" TO 1'-7" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
CENTER LINE OF WATER CLOSET TO SIDE WALL - 1'-6"
AutoCAD SHX Text
AutoCAD SHX Text
FLUSH VALVE HANDLE LOCATED ON APPROACH SIDE OF W.C.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR BEHIND WATER CLOSET - 36" LONG MIN.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR ON SIDE OF WATER CLOSET - 42" LONG MIN.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR MOUNTING HEIGHT- 34" AFF TO CENTER LINE OF BAR.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR DIAMETER - 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
SPACE BETWEEN GRAB BAR AND WALL - 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
TOILET PAPER DISPENSER - 36" MAX FROM REAR WALL, 30" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
BOTTOM EDGES OF MIRRORS WILL BE A MAX. OF 40" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
KNEE CLEARANCE AT LAVATORY - APRON 29" MIN. HEIGHT, 8" MIN. DEPTH.
AutoCAD SHX Text
AutoCAD SHX Text
LAVATORY RIM SURFACE - 34" MAX AFF.
AutoCAD SHX Text
AutoCAD SHX Text PROVIDE ADA SYMBOL SIGNS FOR MEN'S AND WOMEN'S ADA ACCESSIBLE TOILET ROOMS. SIGNS SHALL BE MOUNTED ON THE EXTERIOR WALL ADJACENT TO THE TOILET ROOM DOOR.
AutoCAD SHX Text
AutoCAD SHX Text FLUSH VALVE HANDLE TO BE POSITIONED TO FACE BASIN SIDE OF ALL ADA ACCESSIBLE TOILER ROOMS AND TOILET STALLS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.
AutoCAD SHX Text
POSITION MIRROR AND LAV. FAUCET CENTER TO LAV. BASIN.
AutoCAD SHX Text
AutoCAD SHX Text
( 5'-0" DIA. TYPICAL )
AutoCAD SHX Text
WHEELCHAIR MANEUVERING CIRCLE
AutoCAD SHX Text
5'-0" DIA
AutoCAD SHX Text
ACCESSIBILITY CLEARANCES
AutoCAD SHX Text NOTE: CLEARANCES AS SHOWN ON FLOOR PLANS PER FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text
( 5'-0" DIA. TYPICAL )
AutoCAD SHX Text
WHEELCHAIR MANEUVERING CIRCLE
AutoCAD SHX Text CLEAR FLOOR OR GROUND SPACE SECTION 305.3 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text CLEARANCE AT WATER CLOSETS SECTION 604 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text
TOILET ACCESSORY SCHEDULE
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
TOILET AREAS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (36")
AutoCAD SHX Text
MANUFACTURER/MODEL NUMBER
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text
(SM) SOAP DISPENSER
AutoCAD SHX Text
N.I.C. (BY COUNTY)
AutoCAD SHX Text
(SM) PAPER TOWEL DISPENSER/WASTE RECEPTACLE
AutoCAD SHX Text
BOBRICK B-3699
AutoCAD SHX Text
(SM) TOILET PAPER DISP. (DBL. ROLL)
AutoCAD SHX Text
BOBRICK B-2888
AutoCAD SHX Text G
AutoCAD SHX Text
(SM) SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text
BOBRICK B-254
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text MIRROR (30" x 48")
AutoCAD SHX Text
(SM) STAINLESS STEEL GRAB BARS (42")
AutoCAD SHX Text B
AutoCAD SHX Text
BOBRICK B-6806
AutoCAD SHX Text F
AutoCAD SHX Text
BOBRICK B-2908-1836
AutoCAD SHX Text
(SM) MIRROR (18" X 36")
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text
COUNTERTOP PAPER TOWEL DISPENSER
AutoCAD SHX Text
TORK 302030
AutoCAD SHX Text K
AutoCAD SHX Text
DROP-IN TRASH CHUTE
AutoCAD SHX Text
BOBRICK B-529
AutoCAD SHX Text L
AutoCAD SHX Text
ROBE HOOK
AutoCAD SHX Text
BOBRICK B-76717
AutoCAD SHX Text
ACCESSORY SCHEDULE NOTES
AutoCAD SHX Text
N.I.C. TO BE SUPPLIED BY OWNER
AutoCAD SHX Text
AutoCAD SHX Text (SM) INDICATES "SURFACE MOUNTED", (SR) INDICATES "SEMI RECESSED", (R) INDICATES RECESSED.
AutoCAD SHX Text
AutoCAD SHX Text
SEE TOILET ACCESSORY SCHEDULE FOR ALL TOILET ACCESSORIES.
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE BLOCKING AT ALL WALLS TO RECEIVE WALL MOUNTED GRAB BARS.
AutoCAD SHX Text
AutoCAD SHX Text
SEE ROOM FINISH SCHEDULE FOR ALL FLOOR, WALL AND BASE FINISHES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SANITARY NAPKIN DISPOSAL UNIT SHOULD BE POSITIONED AS SHOWN ON PLAN DRAWINGS AT A HEIGHT TO ALLOW OPENING OF UNIT DOOR. UNITS TO BE INSTALLED AS INDICATED IN ELEVATIONS.
AutoCAD SHX Text
ADA ACCESSIBILITY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
WALL ELEVATION REFERENCE
AutoCAD SHX Text TOILET ROOMS SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR HANDICAPPED ACCESSIBILITY, INCLUDING ALL AMENDMENTS AND REVISIONS TO DATE. MOUNTING HEIGHTS OF FIXTURES AND ACCESSORIES SHALL BE AS FOLLOWS:
AutoCAD SHX Text
WATER CLOSET SEAT HEIGHT - 1'-3" TO 1'-7" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
CENTER LINE OF WATER CLOSET TO SIDE WALL - 1'-6"
AutoCAD SHX Text
AutoCAD SHX Text
FLUSH VALVE HANDLE LOCATED ON APPROACH SIDE OF W.C.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR BEHIND WATER CLOSET - 36" LONG MIN.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR ON SIDE OF WATER CLOSET - 42" LONG MIN.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR MOUNTING HEIGHT- 34" AFF TO CENTER LINE OF BAR.
AutoCAD SHX Text
AutoCAD SHX Text
GRAB BAR DIAMETER - 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
SPACE BETWEEN GRAB BAR AND WALL - 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
TOILET PAPER DISPENSER - 36" MAX FROM REAR WALL, 30" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
BOTTOM EDGES OF MIRRORS WILL BE A MAX. OF 40" AFF.
AutoCAD SHX Text
AutoCAD SHX Text
KNEE CLEARANCE AT LAVATORY - APRON 29" MIN. HEIGHT, 8" MIN. DEPTH.
AutoCAD SHX Text
AutoCAD SHX Text
LAVATORY RIM SURFACE - 34" MAX AFF.
AutoCAD SHX Text
AutoCAD SHX Text PROVIDE ADA SYMBOL SIGNS FOR MEN'S AND WOMEN'S ADA ACCESSIBLE TOILET ROOMS. SIGNS SHALL BE MOUNTED ON THE EXTERIOR WALL ADJACENT TO THE TOILET ROOM DOOR.
AutoCAD SHX Text
AutoCAD SHX Text FLUSH VALVE HANDLE TO BE POSITIONED TO FACE BASIN SIDE OF ALL ADA ACCESSIBLE TOILER ROOMS AND TOILET STALLS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.
AutoCAD SHX Text
POSITION MIRROR AND LAV. FAUCET CENTER TO LAV. BASIN.
AutoCAD SHX Text
AutoCAD SHX Text
( 5'-0" DIA. TYPICAL )
AutoCAD SHX Text
WHEELCHAIR MANEUVERING CIRCLE
AutoCAD SHX Text
5'-0" DIA
AutoCAD SHX Text
ACCESSIBILITY CLEARANCES
AutoCAD SHX Text NOTE: CLEARANCES AS SHOWN ON FLOOR PLANS PER FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text
( 5'-0" DIA. TYPICAL )
AutoCAD SHX Text
WHEELCHAIR MANEUVERING CIRCLE
AutoCAD SHX Text CLEAR FLOOR OR GROUND SPACE SECTION 305.3 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text CLEARANCE AT WATER CLOSETS SECTION 604 - FBC SEVENTH EDITION (2020) ACCESSIBILITY.
AutoCAD SHX Text
SOLID SURFACE COUNTER TOP W/ 4" BACKSPLASH
AutoCAD SHX Text
PLAST. LAM. FIN. ALL EXPOSED SURFACES
AutoCAD SHX Text
DROP-IN TRASH CHUTE, BOBRICK B-529
AutoCAD SHX Text
1/4" VENEER CORE PLYWOOD CABINET BACK.
AutoCAD SHX Text
1/4" VENEER CORE PLYWOOD CABINET BACK.
AutoCAD SHX Text
PLYWOOD FRAMING, TYP.
AutoCAD SHX Text
FLEX PIPE IF REQUIRED
AutoCAD SHX Text
WOOD BRACING AS REQ'D
AutoCAD SHX Text
WALL
AutoCAD SHX Text
UNDERMOUNT SINK, (SEE PLUMB. DWGS.)
AutoCAD SHX Text
SOLID SURFACE COUNTERTOP
AutoCAD SHX Text
LATCHABLE PANEL W/ P. LAM. FINISH
AutoCAD SHX Text
BASE CABINET BEYOND WHERE INDICATED ON ELEVATIONS
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
AutoCAD SHX Text A2.2
AutoCAD SHX Text
BASE CABINET W/ LATCHABLE ACCESS PANEL
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
AutoCAD SHX Text A2.2
AutoCAD SHX Text
BASE CABINET W/ DOORS / WASTE OPENING
AutoCAD SHX Text
SCALE: 1\" = 1'-0"
AutoCAD SHX Text
SCALE: 1\" = 1'-0"
AutoCAD SHX Text
SCALE: \" = 1'-0"
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: \" = 1'-0"
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text J
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text K
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text E
AutoCAD SHX Text TOILET PARTITIONS TO BE SCRANTON HINY HIDERS 55", FLOOR MOUNTED, OVERHEAD BRACED. COLOR: AS SELECTED (TYP.)
AutoCAD SHX Text M
AutoCAD SHX Text
STD. GLASS W/ POLISHED EDGES
PLAST. LAM. ON BASE
1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH 2020 FLORIDA
BUILDING CODE - PLUMBING.
2. LOCATE VALVES IN ACCESSIBLE AREAS WHERE NECESSARY. (12"X12" MIN.)
3. COORDINATE ACTUAL LOCATIONS OF MECHANICAL FLOOR DRAINS WITH
FINAL EQUIPMENT LOCATIONS ON SHOP DRAWINGS.
4. VENT PIPING SHOWN IS ONLY FOR DIAGRAMMATIC PURPOSES. COORDINATE
VTRs WITH HVAC AIR INTAKES.
5. LABEL VALVES ABOVE CEILINGS AND IN CONCEALED SPACES AT CEILING TILE
WITH METAL CEILING TACKS INDICATING VALVE # AND TYPE OF WATER. (i.e.;
BLUE= COLD WATER, LETTERING CW VLV1-001).
6. PROVIDE AND INSTALL WATER WATER HAMMER ARRESTORS IN ACCORDANCE
WITH PDI-WH201 IN ALL HW AND CW SUPPLY PIPING WITH QUICK CLOSING
VALVES AS REQUIRED. AIR CHAMBERS ARE NOT ACCEPTABLE
SUBSTITUTIONS.
7. PROVIDE THERMAL INSULATION FOR HOT WATER AND HOT WATER RETURN
PIPING IN ACCORDANCE WITH THE ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION AND PER SPECIFICATIONS.
8. PROVIDE CLEANOUTS AT THE BASE OF EACH SANITARY STACK. SIZE
CLEANOUTS TO MATCH THE PIPING SERVED. SPACE FLOOR CLEANOUTS AT
100'-0" MAX. ALSO PROVIDE CLEANOUTS IN HORIZONTAL CHANGE OF
DIRECTION > 45°.
9. FIRE CAULK AND SLEEVE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES.
REFER TO LIFE SAFETY PLANS FOR RATED ASSEMBLY LOCATIONS. REFER TO
ARCHITECTURAL SHEETS FOR DETAILS AND UL ASSEMBLY NUMBERS.
10. REFER TO ARCHITECTURAL SHEETS FOR FIXTURE MOUNTING.
11. COORDINATE UNDERGROUND PIPING INVERT ELEVATIONS WITH STRUCTURAL
FOOTING ELEVATIONS AND CIVIL INVERT CONNECTIONS PRIOR TO ANY
UNDERGROUND PIPING INSTALLATIONS. IF FOOTINGS ARE IN CONFLICT AND
WHERE A PIPING ROLL DOWN IS NOT POSSIBLE, COORDINATE WITH GENERAL
CONTRACTOR FOR DROPS IN FOOTING AS REQUIRED.
12. COORDINATE CEILING PIPING AND ELEVATIONS IN SHOP DRAWINGS WITH ALL
OTHER TRADES (I.E. HVAC, FIRE PROTECTION, ELECTRICAL, TELECOMM,
STRUCTURAL, ETC.) PRIOR TO ANY INSTALLATION TO ENSURE PROPER
CLEARANCES AND PENETRATIONS.
13. VALVES AND FITTINGS SHALL BE THE SAME SIZE AS THE PIPING WHERE THEY
ARE LOCATED UNLESS NOTED OTHERWISE.
14. PROVIDE ALL NECESSARY SUPPORTING DEVICES FOR FIXTURES PER
MANUFACTURER INSTALLATION INSTRUCTIONS.
15. PROVIDE ALL FLOOR DRAINS, FLOOR SINKS AND HUB DRAINS WITH DEEP
SEAL P-TRAPS. ALL DRAINS NOT RECEIVING CONTINUOUS DISCHARGE SHALL
BE PROVIDED WITH TRAP PRIMER CONNECTIONS TO ENSURE TRAP SEAL
PROTECTION.
16. ROUGH-IN WASTE AND WATER SUPPLIES FOR FIXTURES AND PERFORM FINAL
CONNECTIONS PER MANUFACTURER RECOMMENDATIONS.
17. ROUGH IN FLUSH VALVE WATER CLOSETS SO THAT THE FLUSH VALVE
HANDLE IS TO THE WIDE SIDE OF THE ROOM.
18. COMPLY WITH THE AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY
GUIDELINES FOR BUILDINGS AND FACILITIES.
19. ALL AUTOMATIC CONTROL, PROTECTIVE OR SIGNAL DEVICES REQUIRED FOR
THE OPERATION SPECIFIED, SHALL BE PROVIDED WITH ANY CONTROL WIRING
AND INSTALLED PER MANUFACTURERS REQUIREMENTS.
20. SHOP DRAWING SUBMITTALS SHALL BE FULLY COORDINATED PRIOR TO
SUBMITTAL.
21. PLASTIC VALVES ARE NOT PERMITTED FOR DOMESTIC WATER USE.
22. OFFSET FLANGES ARE PROHIBITED.
PLUMBING ABBREVIATIONSPLUMBING SYMBOL LEGEND
SYMBOL DESCRIPTION
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
COMPRESSED AIR PIPINGCA
110° HOT WATER PIPINGHW
HOT WATER RETURN PIPINGHWR
STO STORM OVERFLOW (SECONDARY)
ST STORM (PRIMARY)
SANITARY DRAINAGE PIPING (UNDERGROUND)S U/G
SANITARY DRAINAGE PIPING (ABOVE SLAB)SAN
V VENT PIPING
GATE VALVE
PRESSURE GAUGE
THERMOMETER
CHECK VALVE
BALL VALVE
CIRCULATING PUMP
PIPE END CAP
PIPE TURNING DOWN
PIPE TURNING UP
PIPE TURNING DOWN (TEE)
NATURAL GAS PIPING
CLEANOUTS
CW COLD WATER PIPING
CD CONDENSATE PIPING
CIRCUIT SETTER VALVE
OR
PDI-"?" WATER HAMMER ARRESTER & SIZE
THERMOSTATIC MIXING VALVE
HB-? OR WHY-? HOSE BIBB / WALL HYDRANT
FLOW ARROW
P-TRAP
ROLL DOWN
PIPING TEE
ST U/G STORM PIPING (UNDERGROUND)
G
PRESSURE REGULATING VALVE
BUTTERFLY VALVE
SYMBOL DESCRIPTIONSYMBOL DESCRIPTION
AS ABOVE SLAB
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AP ACCESS PANEL
ASTM AMERICAN STANDARDS TESTING MATERIALS
AWWA AMERICAN WATER WORKS ASSOCIATION
BFP BACKFLOW PREVENTER
BS BELOW SLAB
BF BELOW FLOOR
BG BELOW GRADE
CA COMPRESSED AIR
CD CONDENSATE
CO CLEANOUT
CONN CONNECTION
CONT CONTINUOUS
CP CIRCULATING PUMP
CW COLD WATER
DF DRINKING FOUNTAIN
DFU DRAINAGE FIXTURE UNITS
DIA DIAMETER
DN DOWN
DWG DRAWING
DW DOMESTIC WATER
ECO EXTERIOR CLEANOUT
ELEV ELEVATION
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
ºF DEGREES FAHRENHEIT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FIN FINISH
FL FLOOR
FPS FEET PER SECOND
FT FEET
FU FIXTURE UNITS
G NATURAL GAS
GAL GALLON(S)
GPM GALLONS PER MINUTE
GR GREASE WASTE
HB HOSE BIBB
HP HORSEPOWER
HR HOUR
HWR HOT WATER RETURN
HZ HERTZ
IE INVERT ELEVATION
ID INTERNAL DIAMETER
IN INCHES
IPS INTERNATIONAL PIPE STANDARD
IRR IRRIGATION WATER
KW KILOWATT
LAV LAVATORY
LF LINEAR FEET
MAX MAXIMUM
MIN MINIMUM
MNTG MOUNTING
MS MOP SINK
NA NOT APPLICABLE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NSF NATIONAL SANITATION FOUNDATION
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
ORWL OVERFLOW RAIN WATER LEADER
PDI PLUMBING DRAINAGE INSTITUTE
PH PHASE
PPP PRECISION PLUMBING PRODUCTS
PSI POUNDS PER SQUARE INCH
RPM REVOLUTIONS PER MINUTE
RWL RAIN WATER LEADER
S SANITARY
SAN SANITARY
SH SHOWER
SK SINK
SL SODA LINE
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
ST STORM
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TET THERMAL EXPANSION TANK
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
U/G UNDERGROUND
UNO UNLESS NOTED OTHERWISE
UR URINAL
V VENT
VTR VENT THROUGH ROOF
VIV VALVE IN VERTICAL
VLV VALVE
VOL VOLUME
W WATTS
W/ WITH
WC WATER CLOSET
WCO WALL CLEANOUT
WHA WATER HAMMER ARRESTOR
WHY WALL HYDRANT
WFU WATER SUPPLY FIXTURE UNITS
A
B
SIM
A
SECTION SYMBOL:
A = IDENTIFYING LETTER
B = SHEET WHERE SECTION IS SHOWN
SIM =
(ONLY NOTED IF IT APPLIES)
PLUMBING RISER DESIGNATION:
A = RISER IDENTIFYING SYSTEM TYPE
1 =
REVISION CLOUD AND
REVISION NUMBER
SHEET NOTE CALLOUT
A
TITLE SYMBOL ON SHEET WHERE SHOWN
A = IDENTIFYING NUMBER/LETTER
POINT OF CONNECTION
RISER IDENTIFYING SYSTEM NUMBER
SIMILAR
XX
ABBR. DESCRIPTION ABBR. DESCRIPTION
PLUMBING GENERAL NOTES PLUMBING SPECIFICATIONS
GENERAL:
THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK
SPECIFIED IN THIS SECTION.
SCOPE OF WORK:
PROVIDE A COMPLETE PLUMBING SYSTEM AS INDICATED ON THE
DESIGN DRAWINGS AND AS OUTLINED WITHIN THESE
SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO
EQUIPMENT, THE FABRICATION AND/OR INSTALLATION OF THE
SCHEDULED PLUMBING FIXTURES, EQUIPMENT AND RELATED
PIPING. THE COMPLETED PLUMBING SYSTEM SHALL MEET ALL
APPLICABLE STATE & LOCAL CODES AND STANDARDS.
PRODUCTS:
ALL EQUIPMENT, ETC., SHALL BE NEW, AND AS SPECIFIED FREE OF
DEFECTS AS SHOWN ON THE DRAWINGS AND AS INDICATED IN
THESE SPECIFICATIONS. ALL ELECTRICAL POWERED EQUIPMENT
SHALL BE U.L. LISTED.
WATER SUPPLY SYSTEM:
EXTEND WATER SERVICE AS INDICATED ON DESIGN DRAWINGS.
PROVIDE SHOCK ABSORBERS AND VACUUM BREAKERS WHERE
REQUIRED.
PIPE AND FITTINGS ABOVE GROUND - TYPE L HARD COPPER AND
WROUGHT COPPER FITTINGS, WITH SOLDERED JOINTS (USE ONLY
"LEAD FREE" SOLDER)..
PIPE AND FITTINGS BELOW GROUND - TYPE "K" SOFT COPPER.
PROVIDE POLYBUTYLENE WRAPPING.
VALVES (3 INCH AND LARGER) - GATES VALVES - ALL BRONZE,
RISING STEM, DOUBLE WEDGE TAPER SEAT, 125 PSI STEAM
PRESSURE.
VALVES (2-1/2 INCH AND SMALLER) TWO PIECE 400 PSI WSP FULL
PORT BRONZE BODY BALL VALVE WITH THREADED ENDS,
LOCKABLE LEVER HANDLE AND REPLACEABLE TEFLON OR TFE
SEATS.
CHLORINATION - BEFORE BEING PLACED IN SERVICE ALL WATER
DISTRIBUTION SYSTEMS SHALL BE STERILIZED WITH CHLORINE IN
ACCORDANCE WITH PLUMBING CODE AND AWWA C-651 OR C-652
STANDARD PROCEDURE FOR DISINFECTING WATER MAINS.
DRAINAGE SYSTEM:
EXTEND PIPING FROM NEW FIXTURES AND EQUIPMENT AND
CONNECT TO SYSTEMS AS INDICATED ON THE DRAWINGS.
PIPE SLOPE:
2-1/2 INCH DIAMETER AND LESS SHALL BE INSTALLED WITH SLOPE
OF NOT LESS THAN 1/4 INCH PER FOOT.
3 INCH DIAMETER OR LARGER SHALL BE INSTALLED WITH A SLOPE
NOT LESS THAN 1/8 INCH PER FOOT.
PIPE AND FITTINGS:
ABOVE GRADE:
SCHEDULE 40 PVC, DWV COPPER, OR SERVICE WEIGHT CAST IRON
DRAIN, WASTE AND VENT PIPING LOCATED IN FIRE RATED WALL
ASSEMBLIES AND RETURN AIR PLENUMS SHALL BE SERVICE-
WEIGHT CAST IRON WITH SPIGOT FITTINGS OR HUBLESS SOIL PIPE
COUPLINGS AS MANUFACTURED BY MISSION (HW), HUSKEY OR
CLAMPALL (125# OF TORQUE).
BELOW GRADE:
SCHEDULE 40 PVC OR SERVICE WEIGHT CAST IRON WITH HUB AND
SPIGOT FITTINGS OR HUBLESS SOIL PIPE COUPLINGS AS
MANUFACTURED BY MISSION (HW), HUSKEY OR CLAMPALL (125# OF
TORQUE).
PROVIDE CLEANOUTS EVERY 100 FEET, AT CHANGES IN
DIRECTION, AT BASE OF DOWNSPOUTS AND AT BASE OF SOIL AND
WASTE STACKS.
SHOCK ARRESTOR: MIFAB, SIOUX CHIEF OR EQUAL
WALL CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL
FLOOR CLEANOUT: MIFAB, ZURN, JONESPEC, JOSAM OR EQUAL
VENTS SHALL BE EXTENDED TO EXTERIOR OF BUILDING. AIR
ADMITTANCE VALVES ARE NOT ACCEPTABLE.
CONNECTIONS TO MISCELLANEOUS EQUIPMENT:
ROUGH-IN AND CONNECT WATER, WASTE, AND VENT TO
COMPLETE THE INSTALLATION OF EQUIPMENT LISTED ON THE
DRAWINGS.
PLUMBING FIXTURES SHALL BE PROVIDED COMPLETE AS SHOWN
ON THE DRAWINGS WITH ALL REQUIRED SUPPLY, WASTE, SOIL,
AND VENT CONNECTIONS, TOGETHER WITH ALL FITTINGS,
SUPPORTS, FASTENING DEVICES, COCKS, VALVES AND TRAPS.
ALL FIXTURES SHALL HAVE STOP VALVES ON ALL WATER
CONNECTIONS. ALL EXPOSED METAL TRIM ON ALL FIXTURES SHALL
BE POLISHED CHROMIUM PLATED.
ALL EXPOSED PIPES EXTENDING FROM WALL SHALL HAVE
CHROMIUM PLATED BRASS ESCUTCHEON MOUNTED AGAINST
WALL. EXPOSED PVC PIPING AND P-TRAPS ARE UNACCEPTABLE.
THE PLUMBING FIXTURES SHALL BE ROUGHED-IN ACCORDANCE
WITH MANUFACTURER'S "ROUGH-IN INFORMATION". PROVISIONS
FOR MOUNTING WALL FIXTURES SHALL BE MADE WHILE THE WALL
IS BEING BUILT. PROVIDE ADDITIONAL BLOCKING, HANGERS, AND
SUPPORTS AS REQUIRED.
INSULATION:
SHALL BE AS MANUFACTURED BY OWENS-CORNING, MANVILLE,
PITTSBURGH CORNING, ARMSTRONG, OR APPROVED EQUAL.
INSULATION SUNDRIES AND ADHESIVES SHALL BE AS
MANUFACTURED BY BENJAMIN FOSTER, CHILDERS, VIMASCO, OR
APPROVED EQUAL. ALL INSULATION SHALL BE SUITABLE FOR
INSTALLATION IN A RETURN AIR PLENUM.
INSULATE ALL HOT WATER AND HOT WATER RECIRCULATION LINES
WITH MANVILLE MICROLOCK INSULATION WITH ALL SERVICE
JACKETS. THE MINIMUM INSULATION THICKNESS SHALL BE AS
FOLLOWS:
- FOR PIPES UP TO 2" SHALL BE 1" THICK
- FOR PIPES 2.5 AND GREATER SHALL BE 1.5" THICK
- FOR PIPING RUNOUTS (NOT EXCEEDING 12FT.) SHALL BE .5" THICK
IN LIEU OF FIBERGLASS INSULATION SPECIFIED ABOVE THE
CONTRACTOR HAS THE OPTION TO USE AN EQUAL THICKNESS OF
FLEXIBLE CLOSED-FOAM INSULATION (ARMAFLEX AP) OR EQUAL
WITH SELF SEAL SEAMS. INSULATION TO BE RATED FOR USE IN
RETURN AIR PLENUM (FLAME SPREAD RATING OF 25 OR LESS AND
SMOKE DEVELOPED RATING OF 50 OR LESS PER ASTM E-84).
CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND
INSTALLING ADEQUATE AND PROPER INSULATION AND MOISTURE-
SEAL IN A MANNER THAT WILL PERMANENTLY PREVENT THE
ACCUMULATION OF ANY OBJECTIONABLE MOISTURE ON THE
EXTERIOR CONDENSATE DRAIN OR STORM WATER PIPING. OR
OTHER PARTS OF THE SYSTEM. CONTRACTOR SHALL CORRECT THE
CAUSE OF ANY CONDENSATION AND WITHOUT COST TO THE
OWNER, ANY DAMAGES TO BUILDING SURFACES, FURNISHINGS OR
EQUIPMENT CAUSED BY CONDENSATION FROM THIS SYSTEM, FOR
THE FULL PERIOD OF THE GUARANTEE.
HANGERS AND SUPPORTS:
PROVIDE ALL NECESSARY PIPE SUPPORTS, HANGER RODS, CLAMPS
AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT PIPING
AND EQUIPMENT FROM THE BUILDING STRUCTURE.
PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS
REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK.
ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED,
PRIMED AND PAINTED TO PREVENT RUSTING. FINISH COLOR AS
SELECTED BY OWNER.
THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS
NOT ACCEPTABLE FOR SUPPORTS.
WARRANTY/GUARANTEE:
THE CONTRACTOR SHALL
WARRANTY/GUARANTEE AND MAINTAIN THE
STABILITY OF WORK AND MATERIALS AND KEEP
SAME IN PERFECT REPAIR AND CONDITION FOR
THE ENTIRE DURATION OF PROJECT.
DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS
APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE
IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN
EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND
ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND
REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR
FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL
DEFECT OR REPAIRS THERE TO.
SYSTEM IDENTIFICATION:
PROVIDE IDENTIFICATION LABELS ON OR NEAR EACH PIECE OF
MAJOR EQUIPMENT AND EACH OPERATIONAL DEVICE AND
DISCONNECT. THE LABELS SHALL BE CONSTRUCTED OF
ENGRAVED PLASTIC LAMINATE SIGN OR PLASTIC EQUIPMENT
MARKER PERMANENTLY SECURED TO EQUIPMENT. THE
LETTERING SHALL BE A MINIMUM OF 1/2 INCH HIGH FOR
EQUIPMENT NAME AND 3/8 INCH FOR EQUIPMENT INFORMATION.
ALL VALVES SHALL BE TAGGED USING PLASTIC LAMINATE TAGS
AND SECURED WITH BRASS CHAINS. THE TAGS SHALL INDICATE
THE VALVE SIZE, SERVICE AND FUNCTION (IE. 2" CW., MAIN
SERVICE SHUTOFF).
CLEANING, TESTING AND ADJUSTING:
THE PLUMBING CONTRACTOR, AT THIER EXPENSE, SHALL CLEAN,
REPAIR, ADJUST, CHECK, BALANCE, AND PLACE IN SERVICE THE
VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE
EQUIPMENT, ACCESSORIES AND PIPING. THE PLUMBING
CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS,
EQUIPMENT, AND TOOLS REQUIRED TO PERFORM TESTS
REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING
AUTHORITIES.
NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY
INSPECTED AND TESTED.
TESTING:
ALL DOMESTIC WATER PIPING SYSTEMS SHALL BE TESTED FOR
ABSOLUTE TIGHTNESS BY SUBJECTING THE SYSTEM TO
HYDROSTATIC PRESSURE OF 150 PSI GAUGE OR 50 PSI OVER
WORKING PRESSURE, WHICHEVER IS HIGHER FOR A PERIOD OF
NOT LESS THAN EIGHT (8) HOURS. ALL LEAKS SHALL BE REPAIRED
AND THE HYDROSTATIC TEST REAPPLIED UNTIL, FOR AN EIGHT (8)
HOUR PERIOD, NO LEAKS CAN BE FOUND WHILE THE SYSTEM IS
SUBJECT TO THE TEST PRESSURE.
SOIL, VENT PIPES AND CONDENSATE DRAINS SHALL BE TESTED BY
TEMPORARILY PLUGGING ALL OUTLETS AND FILLING THE SYSTEM
WITH WATER TO THE LEVEL OF THE HIGHEST VENT STACK. THE
SYSTEM MUST BE INSPECTED AND ALL LEAKS REPAIRED AND THE
TEST REPEATED UNTIL THE WATER LEVEL DOES NOT DECREASE
FOR A PERIOD OF 24 HOURS.
WATER HAMMER ARRESTOR
SYMBOL
1/2"
PIPE SIZE PDI STANDARD FIXTURE UNIT CAP.
3/4"
1"
1-1/4"
A
B
C
D
1 TO 11
12 TO 32
33 TO 60
61 TO 113
NOT TO SCALE
DATE
SHEET NO.
SCALE:
REVISION/ SUBMISSIONS
SHT. TITLE
SEAL
NO.
AG PROJECT:
COMMISSION NO.
DRAWN:
CHECKED:
DATE:
PH (386) 255-6163208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
RESTROOM RENOVATIONS
DAYTONA BEACH, FLORIDA
207 DR. MARY McLEOD BETHUNE BLVD.
VOTRAN TRANSFER PLAZA
HALL &
ARCHITECT
20-NOV.-2025
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
P-001
PLUMBING LEGENDS, SYMBOLS, & SPECS
AJZ
KJDD
A
N
IE
L G
LO
V
E R
, P .E
F
L Li ce ns e
0121022
SHEET LIST
Sheet Number Sheet Name
P-001 PLUMBING LEGENDS, SYMBOLS, & SPECS
PD111 PLUMBING FLOOR PLANS - DEMO
P-111 PLUMBING FLOOR PLANS - NEW
P-301 PLUMBING DETAILS & SCHEDULES
David Text Box
28-JULY-2025
WOMEN'S
MEN'S
WOMEN'S
MEN'S
WOMEN'S
MEN'S
WOMEN'S
MEN'S
(E)4" FD
(E)4" FD
(E)LAV
(E)SK
(E)LAV
(E)WCO
(E)WCO
(E)WC (E)WC
(E)LAV (E)LAV
(E)WC
(E)LAV
(E)UR
2 2
2 2
(E)4" S
(E)4" S (E)2 1/2" V
(E)1 1/4" V(E)2" V
(E)2" V (E)2 1/2" V (E)2" V (E)1 1/2" V
(E)1 1/4" V
(E)1" CW (E)1 1/4" CW
(E)1 1/2" CW
(E)1/2" HW
(E)2" CW
(E)3/4" HW
(E)1 1/2" CW
(E)3/4" HW
(E)1/2" HW
(E)1/2" CW
(E)3/4" CW
(E)1/2" HW(E)1/2" HW
(E)1 1/2" CW(E)1 1/4" CW(E)1" CW
(E)SK
(E)LAV
(E)LAV
(E)WC (E)WC
(E)LAV (E)LAV
(E)WC
(E)LAV
(E)UR
2 2
2 2
(E)2" CW & 3/4" HW BACK TO
WATER HEATER LOCATED
IN JANITOR'S CLOSET
DATE
SHEET NO.
SCALE:
REVISION/ SUBMISSIONS
SHT. TITLE
SEAL
NO.
AG PROJECT:
COMMISSION NO.
DRAWN:
CHECKED:
DATE:
PH (386) 255-6163208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
RESTROOM RENOVATIONS
DAYTONA BEACH, FLORIDA
207 DR. MARY McLEOD BETHUNE BLVD.
VOTRAN TRANSFER PLAZA
HALL &
ARCHITECT
20-NOV.-2025
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
1/2" = 1'-0"
PD111
PLUMBING FLOOR PLANS - DEMO
AJZ
KJDD
A
N
IE
L G
LO
V
E R
, P .E
F
L Li ce ns e
0121022
1/2" = 1'-0"PD111
1 PLUMBING SANITARY FLOOR PLAN - DEMO
1/2" = 1'-0"PD111
3 PLUMBING DOMESTIC WATER FLOOR PLAN - DEMO
DRAWING NOTES:
1. EXISTING TILE WALL TO REMAIN AND SHALL NOT BE DISTURBED.
2. ALL EXISTING PIPING SHALL REMAIN. IF ANY EXISTING PIPING PENETRATING WALLS IS REQUIRED TO
BE REMOVED FOR CONNECTION TO NEW FIXTURES, A COVER PLATE SHALL BE PROVIDED.
CODED NOTES:
REMOVE AND REPLACE EXISTING GRATE ON FLOOR DRAIN. CLEAN FLOOR DRAIN PRIOR TO
INSTALLATION OF NEW GRATE.
DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. PREPARE PIPE CONNECTIONS FOR NEW FIXTURE.
DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. REMOVE SANITARY AND VENT PIPING BACK TO
POINT INDICATED AND CAP.
DEMOLISH AND DISPOSE OF PLUMBING FIXTURE. REMOVE PRESSURE PIPING BACK TO POINT
INDICATED AND CAP.
0 1' 2' 4' 6'
1/2" = 1'-0" N
David
MEN'S
VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N
VITREOUS CHINA BATHROOM SINK CAXTON K-2210-N
WOMEN'S
MEN'S
VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N VITREO U S CH IN AB ATHRO OM SINKC AXTONK - 2210-N
VITREOUS CHINA BATHROOM SINK CAXTON K-2210-N
(E)4" S
(E)4" S
(E)SK
(E)2 1/2" V
(E)1 1/4" V(E)2" V
(E)2" V (E)2 1/2" V (E)2" V (E)1 1/2" V
(E)1 1/4" V
(E)WCO
(E)WCO
L-1 L-1
L-1
(E)4" FD-1
(E)4" FD-11
2 2
WC-1
U-15
WC-15 WC-15
(E)1/2" HW
(E)SK
(E)1" CW (E)1 1/4" CW
(E)1 1/2" CW
(E)1/2" HW
(E)2" CW
(E)3/4" HW
(E)1 1/2" CW
(E)3/4" HW
(E)1/2" CW
(E)3/4" CW
(E)1/2" HW(E)1/2" HW
(E)1 1/2" CW(E)1 1/4" CW(E)1" CW
L-1
WC-1
U-1
3 L-13
L-13
WC-14 WC-14
DATE
SHEET NO.
SCALE:
REVISION/ SUBMISSIONS
SHT. TITLE
SEAL
NO.
AG PROJECT:
COMMISSION NO.
DRAWN:
CHECKED:
DATE:
PH (386) 255-6163208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
RESTROOM RENOVATIONS
DAYTONA BEACH, FLORIDA
207 DR. MARY McLEOD BETHUNE BLVD.
VOTRAN TRANSFER PLAZA
HALL &
ARCHITECT
20-NOV.-2025
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
1/2" = 1'-0"
P-111
PLUMBING FLOOR PLANS - NEW
AJZ
KJDD
A
N
IE
L G
LO
V
E R
, P .E
F
L Li ce ns e
0121022
1/2" = 1'-0"P-111
1 PLUMBING SANITARY FLOOR PLAN - NEW
1/2" = 1'-0"P-111
2 PLUMBING DOMESTIC WATER FLOOR PLAN - NEW
DRAWING NOTES:
1. EXISTING TILE WALL TO REMAIN AND SHALL NOT BE DISTURBED.
2. EXISTING WATER SUPPLY AND SANITARY CONNECTION LOCATIONS SHALL REMAIN. NEW FIXTURES
SHALL CONNECT TO EXISTING WATER SUPPLY AND SANITARY CONNECTIONS.
CODED NOTES:
REFER TO CODED NOTE 1 / PD111.
ADJUST/REPLACE P-TRAP AS REQUIRED TO LINE UP WITH NEW LAVATORY DRAIN.
CONNECT (E)1/2" CW & HW TO ZURN ZW1070XL THERMOSTATIC MIXING VALVE MOUNTED UNDER THE
COUNTER/LAV. ROUTE 1/2" TEMPERED WATER TO LAV.
CONNECT UR/WC TO (E)CW.
CONNECT UR/WC TO (E)SANITARY
0 1' 2' 4' 6'
1/2" = 1'-0"
N
David
EXISTING WATER
SUPPLY
WATER CLOSET
SOLID RING PIPE SUPPORT (2 REQUIRED)
GRAB BAR (BY OTHERS)
FLUSH VALVE
FINISHED WALL
WATER CONNECTION TO
MATCH EXISTING
LOCATION AND HEIGHT
BATTERY POWERED SENSOR
FAUCET. REFER TO SCHEDULE
FOR FAUCET TYPE
LAVATORY
SUPPLY ANGLE
STOP (TYP)
1/2" CW SUPPLY
1/2" HW SUPPLY
95°F (ADJUSTABLE)
TEMPERED WATER
ASSE 1070
THERMOSTATIC
MIXING VALVE
ELECTRONICS
MODULE
NOT TO SCALE
DATE
SHEET NO.
SCALE:
REVISION/ SUBMISSIONS
SHT. TITLE
SEAL
NO.
AG PROJECT:
COMMISSION NO.
DRAWN:
CHECKED:
DATE:
PH (386) 255-6163208 MAGNOLIA AVENUE
DAYTONA BEACH, FLORIDA 32114
AA-C000925
FAX (386)257-5650
www.hoarchitects.com
RESTROOM RENOVATIONS
DAYTONA BEACH, FLORIDA
207 DR. MARY McLEOD BETHUNE BLVD.
VOTRAN TRANSFER PLAZA
HALL &
ARCHITECT
20-NOV.-2025
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
P-301
PLUMBING DETAILS & SCHEDULES
AJZ
KJDD
A
N
IE
L G
LO
V
E R
, P .E
F
L Li ce ns e
0121022
N.T.S.
WATER CLOSET, FLOOR MOUNTED DETAIL
PLUMBING FIXTURE SCHEDULE
MARK FIXTURE MANUFACTURER MODEL NO. TYPE MATERIAL WASTE VENT CW HW REMARKS
L-1 LAVATORY
(ADA ACCESSIABLE)
AMERICAN
STANDARD
0491.019 DROP IN VITREOUS
CHINA
1-1/2" 2" 1/2" 1/2" 19-1/8” ROUND VITREOUS CHINA, SELF-RIMMING, COUNTERTOP LAVATORY WITH 4" CENTER
HOLES. FRONT OVERFLOW DESIGN. WASTE: 1-1/4" O.D. FAUCET: HYDROTEK 5000E BATTERY
POWERED FAUCET WITH OPTIONAL 4" CENTER HOLE COVER PLATE. GRID DRAIN: MCGUIRE
PRODRAIN – OFFSET GRID DRAIN FOR WHEEL CHAIR ACCESSIBILITY. PTRAP: ZURN Z8700-8B-PC.
TRAP WRAP: Z8946-1-NT. SUPPLY: MCGUIRE 2165CC. MIXING VALVE: ZURN ZW1070XL.
U-1 URINAL
(ADA ACCESSIBLE)
AMERICAN
STANDARD
6590.001 FLUSH VALVE
WALL MOUNT
VITREOUS
CHINA
3" 2" 1" - WALL MOUNTED URINAL, VITREOUS CHINA, HIGH EFFICIENCY URINAL, 1.0 GPF, 3/4" TOP SPUD, WITH VACUUM BREAKER AND CONTROL STOP. FLUSH VALVE: SLOAN ROYAL 180-1.0. SENSOR:
SLOAN EBV-200-A (BATTERY). INSTALL URINAL AT HEIGHT TO MATCH EXISTING WATER
CONNECTION TO FLUSH VALVE. MAX ADA HEIGHT IS 17” AFF. CARRIER: Z1221.
WC-1 WATER CLOSET
(ADA ACCESSIBLE)
AMERICAN
STANDARD
3043.001 FLUSH VALVE
FLOOR MOUNT
VITREOUS
CHINA
4" 2" 1-1/4" - FLOOR MOUNTED TOILET AT ADA HEIGHT, VITREOUS CHINA, 1.6 GPF WITH SIPHON JET FLUSHING
ACTION. ELONGATED FRONT RIM, AND 1-1/2" TOP SPUD CONNECTION. SEAT: AMERICAN
STANDARD 5901.100. FLUSH VALVE: SLOAN-REGAL 111-1.6. SENSOR: SLOAN EBV-200-A (BATTERY).
N.T.S.
SENSOR FAUCET DETAIL
David
-ELECTRIC DUCT HEATER (W/PANEL
CLEARANCE)
-MANUAL BALANCING DAMPER
-MOTOR OPERATED CONTROL DAMPER
(MOD)
-FLEXIBLE CONNECTION
-ACCESS DOORS, VERTICAL OR HORIZONTAL
-DOOR GRILLE
-UNDERCUT DOOR
-SPIN-IN TAKE-OFF
-DUCT ELBOW UP THROUGH ROOF OR SLAB
ABOVE
-RECTANGLE-TO-ROUND TAKE-OFF
DNUP
-TRANSITION, SQUARE TO ROUND
-CEILING EXHAUST
-CEILING RETURN
-STANDARD BRANCH TAKE-OFF
-RADIUS ELBOW
-TRANSITION, ECCENTRIC
-FLEXIBLE DUCT
-CHANGE OF ELEVATION
-DUCT ELBOW, NEGATIVE PRESSURE,
RETURN
-DUCT ELBOW, EXHAUST
-DUCT ELBOW, POSITIVE PRESSURE
(SUPPLY)
-NEW DUCTWORK, FIRST DIMENSION IS SIDE
SHOWN
-TRANSITION, CONCENTRIC
-SQUARE THROAT ELBOW
W/TURNING VANES
-RECTANGULAR/ROUND BRANCH TAKE-
OFF
OR ROUND/ROUND BRANCH TAKE-OFF
-SQUARE THROAT TEE
-RADIUS TEE
-SUPPLY REGISTER OR GRILLE
-RETURN/EXHAUST REGISTER OR GRILLE
(VERTICAL MOUNT, SIDEWALL)
(VERTICAL MOUNT, SIDEWALL)
-CEILING DIFFUSER, ROUND NECK
(CEILING DIFFUSERS ARE 4-WAY THROW UNO)
-CEILING DIFFUSER, RECTANGULAR OR
SQUARE NECK (CEILING DIFFUSERS
ARE 4-WAY THROW UNO)
-TEMPERATURE SENSOR
-MOTORIZED CONTROL DAMPER
-HUMIDISTAT/HUMIDITY SENSOR
-THERMOSTAT/TEMPERATURE SENSOR
-REVISION REFERENCE
-DETAIL REFERENCE: TOP - DETAIL#;
BOTTOM - DRAWING# SHOWN ON
-STATIC PRESSURE SENSOR
-DUCT SMOKE DETECTOR
FF -FINAL FILTERS
DDC -DIRECT DIGITAL CONTROLS
PRS -PRESSURE REDUCING STATION
SP -STATIC PRESSURE
-CFM (CUBIC FEET PER MINUTE)
P -CHANGE IN PRESSURE
CV -CONSTANT AIR VOLUME
-ROOFTOP AIR HANDLING UNITRTU
RS/L -REFRIGERANT SUCTION & LIQUID LINES
C -OUTSIDE AIR LOUVEROAL
-VARIABLE AIR VOLUMEVAV
-SUPPLY AIRSA
-ROOFTOP HEAT PUMPRHP
-REHEAT COILRHC
-REVOLUTIONS PER MINUTERPM
-RETURN AIRRA
-POLYVINYL CHLORIDE PIPEPVC
-PSI GAUGEPSIG
-POUNDS PER SQUARE INCHPSI
-PRESSURE REDUCING VALVEPRV
-OUTSIDE AIROA
-NOT TO SCALENTS
-NORMALLY OPENNO
-NORMALLY CLOSEDNC
-LINEAR DIFFUSERLD
-LEAVING WATER TEMPERATURELWT
-LEAVING AIR TEMPERATURELAT
-GALLONS PER MINUTEGPM
-FEET PER MINUTE
-FIRE DAMPER
-FAN COIL UNIT
-ENTERING WATER TEMPERATURE
-ENTERING AIR TEMPERATURE
-DOWN
-CONDENSING UNIT
-CUBIC FEET PER MINUTE
-CHANGE IN TEMPERATURE
-COOLING TOWER
-CONDENSATE
-CENTER LINE
-BRITISH THERMAL UNIT
-BRAKE HORSEPOWER
-BOTTOM OF PIPE
-ACCESS PANEL
-ABOVE FINISHED FLOOR
FPM
FD
FCU
EWT
EAT
DN
CU
CFM
T
CT
CD
BTU
BOP
BHP
AP
AFF
-AIR HANDLING UNITAHU
MBH -THOUSAND BTUs PER HOUR
ESP -EXTERNAL STATIC PRESSURE
KW -KILOWATT
MCA -MINIMUM CIRCUIT AMPS
MOCP -MAXIMUM OVER CURRENT PROTECTION
UNO
TSP -TOTAL STATIC PRESSURE
-VOLTS/PHASEV/PH
VFD -VARIABLE FREQUENCY DRIVE
-UNLESS NOTED OTHERWISE
FLA -FULL LOAD AMPS
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
HVAC ABBREVIATIONSHVAC SYMBOL LEGEND
-BACKDRAFT DAMPER
MOD -MOTOR OPERATED CONTROL DAMPER (MOD)
-PACKAGED TERMINAL AIR CONDITIONERPTAC
-SHEET NOTE CALLOUT
-CEILING MOUNTED ACCESS DOOR
-RECTANGULAR DUCT SECTION UP,
EXHAUST
-RECTANGULAR DUCT SECTION UP,
NEGATIVE PRESSURE, RETURN
-RECTANGULAR DUCT SECTION UP, POSITIVE
PRESSURE,
SUPPLY OR OUTSIDE AIR
-ROUND DUCT SECTION UP
SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION
-ABOVE FINISHED ROOFAFR
-BUTTERFLY VALVEBFV
c
T
H
DOWN UP W/IN FLOOR
UC
M-1
XX
XX
M
T
SP
BD
M
L
VRF -VARIABLE REFRIGERANT FLOW
-EXHAUST AIREA
-CLEAN OUTCO
-CONNECT TO EXISTING
-DEMOLISH TO POINT INDICATED
-FIRE & SMOKE DAMPER
(WITH ACCESS PANEL)
-FIRE DAMPER (WITH ACCESS PANEL)
-HUMIDITY SENSOR (DUCT MOUNTED)H
-CARBON DIOXIDE SENSOR (DUCT MOUNTED)CO2
-CARBON DIOXIDE SENSORCO2
1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.
TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.
2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR
FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH
AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO
OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST.
3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC
DUCT CONSTRUCTION STANDARD.
4. INSTALL ALL FIRE DAMPERS, SMOKE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS IN
ACCORDANCE WITH MANUFACTURE'S INSTALLATION DIRECTIONS. PROVIDE ACCESS DOORS TO
ALLOW COMPLETE INSPECTION AND MAINTENANCE OF ALL DEVICES.
5. PROVIDE 1.5R ELBOWS IN DUCTWORK AS INDICATED. IF 1.5R ELBOWS DO NOT FIT, PROVIDE 1.0R ELBOWS. IF 1.0R ELBOWS DO NOT FIT, PROVIDE 90 DEGREE RECTANGULAR DUCT ELBOWS WITH
TURNING VANES.
6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT
FURNISHED.
7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED
CEILING PLANS AND EQUIPMENT OF ALL TRADES.
8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48"
ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER
EQUIPMENT, FURNITURE, AND DOOR SWINGS.
9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE
ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.
10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.
11. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.
MECHANICAL EQUIPMENT TAGS
12. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR
PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED.
13. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR
OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.
14. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO
FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.
15. COORDINATE SIZE REQUIREMENTS OF ALL CONCRETE HOUSEKEEPING PADS UNDER ALL FLOOR-
MOUNTED EQUIPMENT. SEE STRUCTURAL DRAWINGS FOR PAD DETAILS AND SPECIFICATIONS.
16. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS
AND OTHER AIR DISTRIBUTION DEVICES.
17. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO FANS, AIR HANDLING
UNITS, AND FAN COIL UNITS.
18. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE
CONNECTED.
19. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS.
20. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.
21. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 10'-0" CLEAR FROM ALL PLUMBING VENTS AND EXHAUST AIR DISCHARGE LOCATIONS. LOWEST POINT OF EACH OUTSIDE AIR INTAKE ON ROOF SHALL
BE A MINIMUM OF 24" ABOVE ROOF.
22. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.
23. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED
FULL SIZE TO THE NEAREST PLUMBING DRAIN.
GENERAL NOTES
-AIR HANDLING UNIT
-AIR DISTRIBUTION DEVICE
AHU-1
VTU-1-1
-ELECTRIC DUCT HEATEREDH-1-1
CFM
SIZE TYPE
SSR - SUPPLY
SRR - RETURN
12x6 SSR
300 CFM
OAV - OUTSIDE AIR VALVE
AHU
NUMBER HEATER NUMBER
TAG
CFM
VTU - VARIABLE TERMINAL UNIT
TERMINAL UNIT TYPE
TERMINAL NUMBER
AHU/OAU NUMBER
AHU NUMBER
45145
BASIC MATERIALS
EXISTING TO BE REMOVED (HEAVY, DASHED LINE)
EX…
This is the start of the file's text. The full file is on GovTribe.