This is a bid set document for Capital Improvement Project (CIP) #4211 issued by the City of Beaverton, Oregon, detailing the design specifications and construction requirements for SW Hart Road Traffic Circle Public Waterline Improvements. The project encompasses the installation of approximately 1,800 linear feet of zinc-coated ductile iron potable water pipe with polyethylene wrapping in sizes of 12", 8", 6", and 4" diameter. The scope includes four waterline connection details, multiple water service installations and abandonments, fire hydrant assembly installations, water valve installations, and thrust block construction. The project is located along a heavily traveled residential street in the Hart Road traffic circle area and includes 21 sheets of construction plans with detailed alignments, profiles, connection details, and standard engineering drawings. The document specifies that all materials must be domestically manufactured, new materials only, with no rebuilt or foreign-manufactured components permitted. Contractor responsibilities include providing temporary and permanent blow-off assemblies, pressure testing at 150 PSI minimum, chlorination and disinfection in accordance with Oregon Health Division guidelines, erosion prevention and sediment control measures, traffic control compliance with the Manual for Uniform Traffic Control Devices, and restoration of landscaping and ground cover. The project requires coordination with existing utilities, including 5 working days' advance notice to the City for planned service disruptions, and all existing water mains and services must remain operational until new facilities are connected and in service.
The document establishes construction standards requiring all mainline pipes to be push-on cement-lined zinc-coated ductile iron Class #52 with Tyton joints and all mechanical joints to conform to ANSI A-21.11 specifications. Backfill in rights-of-way and traffic areas must be compacted crushed rock achieving 95 percent maximum density per AASHTO T-99 standards. Water service installations include both 1-inch and 2-inch connections per City of Beaverton standard details, with contractors responsible for furnishing materials, installing new piping, and coordinating final service connections with the City Water Department. The City will install new meters, and private plumbing permits are required at contractor expense for work on the customer side of meters. All valves must include valve boxes and lids per technical specifications, fire hydrants must maintain minimum 36-inch clear space, and all survey monuments must be located and protected. The project mandates contractor compliance with City of Beaverton standards, Oregon APWA/ODOT standard specifications, Clean Water Services standards, and Oregon Administrative Rules Chapter 333. As-built information must be submitted upon completion, and the contractor shall notify the City Inspector at least 48 hours prior to project commencement and maintain City-approved construction plans on-site during all work phases.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SW HART RD
SW 27TH ST
SORRENTO RD
SW
T
R
IL
LI
U
M A
VE
SW
TH
C T
SW
JU
NI
PE
R
TE
R
SW
S
O R
R
EN
TO
R
D
SW
T
R
IL
LI
U
M C
T
SW
TH
A
VE
SW GLENN DR
SW
DALE AVE
SW
CITY OF BEAVERTON
1S1W SECTION 21, COB INDEX 3816
CIP# 4211 - SW HART RD TRAFFIC CIRCLE
PUBLIC WATERLINE IMPROVEMENTS
Scholls Ferry Rd
Barrows Rd
Tile Flat Rd
5t h Av e
Weir Rd
Brockman St
Allen Blvd
Denney Rd
M ur ra y
Bl vd Hall Blvd
Barnes Rd
Cornell Rd Sunset Hwy
Walker Rd
Jenkins Rd
BH Hwy
SHEET INDEX
Canyon Rd
Sheet No.17
0t h
Av e
Sheet Title
Hart Rd
COVER SHEET
Davis Rd
Nora Rd
Garden Home Rd
ABBREVIATIONS & SYMBOLOGY
3Farmington Rd
GENERAL NOTES
TV Hwy Ced ar H ills B lvd
4-16 Scholls Ferry Rd
PROPOSED WATER PLAN & PROFILE
17-20
VICINITY MAP
CONNECTION DETAILS
N.T.S.
Project Site
ABANDONMENT
CONTACTS LIST
Project Manager Phone Number
COB Project Manager - Eduardo Roman
(503) 686-1890
Company Phone Number Comcast - Dispatch (503) 617-1212
Frontier - David Carnley (503) 940-9000
Verizon - Daniel Ruiz (503) 350-3251
PGE - Outage & Emergencies (503) 464-7777 or (800) 544-1795
BPA - Jim Clark (503) 304-5906 (O) or (503) 758-3883 (C)
Kinder Morgan (866) 762-8442
NW Natural (800) 882-3377
CoB Utilities (503) 526-2261
TVWD Water (503) 848-3000
CWS Storm/Sewer (503)547-8100
ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-001-0001 through
952-001-0090. You may obtain copies of the rules by calling the center.
NOTE: The telephone number for the Oregon Utility Notification Center is (503) 232-1987.
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
DesignedAppv'd
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
C O
VE
R
S H
EE
T
ERRBD
Benchmark/Basis of Bearing ORS 92.044
THIS DESIGN COMPLIES WITH ORS 92.044(7) IN THAT NO UTILITY
INFRASTRUCTURE IS DESIGNED TO BE LOCATED WITHIN ONE FOOT
OF A SURVEY MONUMENT LOCATION SHOWN ON A SUBDIVISION OR
PARTITION PLAT. NO DESIGN MODIFICATION OR FINAL FIELD
LOCATION CHANGE SHALL BE PERMITTED IF IT WOULD CAUSE ANY
UTILITY INFRASTRUCTURE TO BE PLACED WITHIN A PROHIBITED
AREA.
PROJECT COORDINATES AND ELEVATIONS:
COORDINATES ARE STATE PLANE OREGON NORTH
ELEVATIONS ARE WASHINGTON COUNTY, BASED OFF BM 716, BEING A PK NAIL IN LEAD SET IN THE
SOUTH CURB OF SW BROCKMAN ROAD ABOUT 400' EAST OF SW DAVIES ROAD, HAVING AN
ELEVATION OF 270.005 FEET. SITE BENCHMARK IS A BRASS CAP MARKED "OTAK CONTROL" SET IN THE NORTHERLY TOP OF CURB OF SW 22ND STREET, BEING 20 FEET WEST OF THE CENTERLINE OF
SW WISTERIA PLACE, HAVING AN ELEVATION OF 231.29 FEET.
UNITS IN INTERNATIONAL FEET
N
PROJECT
AREA
PROJECT SITE MAP - N.T.S.
BID
S
ET
410 PRESSURE ZONE
APPROX. STATIC PRESSURE: 78 PSI
22-33 COB ENGINEERING STD DRAWINGS
PROPOSEDEXISTING
SYMBOLOGYABBREVIATIONS
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
BID
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
A B
B R
EV
IA
TI
O
N S
A N
D S
YB
O
LS
ERRBD
AC ASPHALTIC CONCRETE
AD ALGEBRAIC DIFFERENCE
ADA AMERICANS WITH DISABILITIES ACT
APPROX APPROXIMATELY
APPVD APPROVED
APWA AMERICAN PUBLIC WORKS ASSOCIATION
AWWA AMERICAN WATER WORKS ASSOCIATION
BFV BUTTERFLY VALVE
BGN BEGIN
BO BLOW OFF
BVCE BEGIN VERTICAL CURVE ELEVATION
BVCS BEGIN VERTICAL CURVE STATION
COB, C.O.B CITY OF BEAVERTON
CB CATCH BASIN
CI CAST IRON
CL CENTERLINE
CMP CORRUGATED METAL PIPE
CO CLEANOUT
CONC CONCRETE
CPLG COUPLING
CU COPPER
CWS CLEAN WATER SERVICES
DEFL DEFLECT
DTL DETAIL
DI DUCTILE IRON
DIA DIAMETER
EA EACH
EG EXISTING GRADE
ESMT EASEMENT
EVCE END VERTICAL CURVE ELEVATION
EVCS END VERTICAL CURVE STATION
EX, X EXISTING
FG FINISHED GROUND
FITG FITTING
FH FIRE HYDRANT
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FL FLOW LINE
G GAS
GALV GALVANIZED
GB GRADE BREAK
GR GRADE
HDPE HIGH DENSITY POLYETHLENE
HYD HYDRANT
IE INVERT ELEVATION
IP IRON PIPE
IR IRON ROD
JT JOINT
K RATE OF CURVATURE
LAT LATERAL
LF LINEAL FEET
LS LONG SLEEVE
L LEFT
LVC LENGTH OF VERTICAL CURVE
MAX MAXIMUM
MATL MATERIAL
MECH MECHANICAL JOINT
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
NIC NOT IN CONTRACT
OC ON CENTER
OD OUTSIDE DIAMETER
PWR POWER
PRV PRESSURE REDUCING VALVE
PT POINT
PVI POINT OF VERTICAL INTERSECTION
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
RW RIGHT-OF-WAY
RCP REINFORCED CONCRETE PIPE
RDCR REDUCER
REINF REINFORCED CONCRETE PIPE
REQ'D REQUIRED
RESTR RESTRAINED
RIM RIM ELEVATION
R RIGHT
RSGV RESILIENT SEATED GATE VALVE
SW SIDEWALK
SAN, SS SANITARY SEWER
SCHED, SCH SCHEDULE
SD, STM STORM
SLV SLEEVE
STA STATION
SVC SERVICE
TB THRUST BLOCK
TBC TOP BACK CURB
TFC TOP FACE CURB
T, TEL TELEPHONE
TEMP TEMPORARY
THRD THREADED(ED)
T.O.P. TOP OF PIPE
TYP TYPICAL
UNK UNKNOWN
VERT VERTICAL
WAT WATER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
BLOW OFF
AutoCAD SHX Text
REDUCER
AutoCAD SHX Text
THRUST BLOCK
AutoCAD SHX Text
UTILITY POLE
AutoCAD SHX Text
ELECT. VAULT
AutoCAD SHX Text
TEL MANHOLE
AutoCAD SHX Text
TEL VAULT
AutoCAD SHX Text
TEL PEDESTAL
AutoCAD SHX Text
CABLE RISER
AutoCAD SHX Text
LIGHT POLE
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
STREET LIGHT
AutoCAD SHX Text
DECID TREE
AutoCAD SHX Text
CONFIR TREE
AutoCAD SHX Text
SAN CLEANOUT
AutoCAD SHX Text
SANITARY MANHOLE
AutoCAD SHX Text
STORM CLEANOUT
AutoCAD SHX Text
STORM MANHOLE
AutoCAD SHX Text
CATCH BASIN
AutoCAD SHX Text
SIGN
AutoCAD SHX Text
ABANDONED UTILITY
AutoCAD SHX Text
CABLE TV
AutoCAD SHX Text
POWER
AutoCAD SHX Text
FIBER OPTICS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
RIGHT OF WAY
AutoCAD SHX Text
SANITARY SEWER
AutoCAD SHX Text
STORM
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
WATER
AutoCAD SHX Text
CL ROW
AutoCAD SHX Text
PROP LINE
AutoCAD SHX Text
WATER
AutoCAD SHX Text
EASEMENT
AutoCAD SHX Text
OVERHEAD LINES
AutoCAD SHX Text
WM
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
BLOW OFF
AutoCAD SHX Text
REDUCER
AutoCAD SHX Text
THRUST BLOCK
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text
FO
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
CO
AutoCAD SHX Text D
AutoCAD SHX Text
CO
AutoCAD SHX Text
WM
AutoCAD SHX Text
STRADDLE BLOCK
SW 27TH ST
SORRENTO RD
SW
T
R
IL
LI
U
M A
VE
SW
TH
C T
SW
JU
NI
PE
R
TE
R
SW
S
O R
R
EN
TO
R
D
SW
T
R
IL
LI
U
M C
T
SW
TH
A
VE
SW GLENN DR
SW
DALE AVE
SW
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
G
EN
ER
A
L N
O
TE
S
ERRBD
WATERLINE CONSTRUCTION NOTES
1. CONTRACTOR SHALL INFORM OWNER AND OWNER'S REPRESENTATIVE 5 WORKING
DAYS IN ADVANCE OF CONSTRUCTION AND/OR PLANNED DISRUPTION OF WATER
SERVICE. CONTRACTOR SHALL NOT ASSUME SHUTDOWN TIMES, BUT WILL RATHER
SCHEDULE AND COORDINATE SHUTDOWNS WITH AFFECTED UTILITIES.
2. OWNER WILL PROVIDE NOTIFICATION TO AFFECTED WATER USERS FOR PLANNED
SERVICE DISRUPTIONS.
3. OWNER WILL PROVIDE SURVEYING AS REQUIRED FOR NEW WATERLINE
CONSTRUCTION.
4. OPERATION OF EXISTING VALVES SHALL ONLY BE PERFORMED BY CITY STAFF.
5. EXISTING WATER MAINS AND SERVICES SHALL BE KEPT IN OPERATIONS UNTIL NEW
MAINS ARE CONNECTED AND IN SERVICE.
6. CONTRACTOR SHALL PROVIDE TEMPORARY THRUST BLOCKING WHERE REQUIRED ON
THOSE FITTINGS WHICH WILL SEE SERVICE PRESSURE BEFORE CONCRETE THRUST
BLOCK DEVELOPS FULL STRENGTH.
7. CONTRACTOR SHALL PLACE 8-MIL PLASTIC SHEETING BETWEEN THRUST BLOCK AND
PIPE FITTINGS.
8. ALL VALVES SHALL INCLUDE VALVE BOXES AND LIDS AS OUTLINED IN THE TECHNICAL
SPECIFICATIONS AND DRAWINGS.
9. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH AWWA, CITY OF BEAVERTON,
AND THE UNIFORM PLUMBING CODE AS APPLICABLE. ALL MATERIALS SHALL BE OF NEW
MANUFACTURE, AND MUST BE DOMESTIC. NO REBUILT OR USED MATERIALS WILL BE
ALLOWED. ALL MATERIALS SHALL HAVE DOCUMENTATION PROVIDING EVIDENCE THAT
THE MATERIALS USED IN THIS CONSTRUCTION WERE MANUFACTURED IN THE UNITED
STATES. NO FOREIGN MANUFACTURED MATERIALS WILL BE ALLOWED.
10. ALL MAINLINE PIPES SHALL BE PUSH-ON CEMENT-LINED ZINC COATED DUCTILE IRON,
CLASS #52 WITH TYTON JOINTS. ALL MECHANICAL JOINTS SHALL CONFORM TO ANSI
A-21.11.
11. FIRE HYDRANT ASSEMBLIES SHALL CONFORM TO THE CITY OF BEAVERTON'S
ACCEPTED BRANDS AND MODELS.
12. FIRE HYDRANTS SHALL BE LOCATED TO ALLOW A MINIMUM OF 36" CLEAR SPACE
SURROUNDING ALL PORTIONS OF THE HYDRANT. THERE SHALL ALSO BE NO
OBSTRUCTIONS DIRECTLY IN LINE WITH ANY OF THE PORTS OF THE HYDRANT FOR A
DISTANCE OF 5 FEET.
13. ALL BACKFILL IN THE RIGHT OF WAY OR OTHER TRAFFIC AREAS SHALL BE ¾"-0"
COMPACTED CRUSHED ROCK, COMPACTED TO 95 PERCENT OF MAXIMUM DENSITY AS
OBTAINED BY AASHTO T-99 COMPACTION TEST.
14. CONTRACTOR SHALL FURNISH AND INSTALL WATER SERVICES, 1" (OR 2") SHORT (OR
LONG) SIDE AS SPECIFIED SERVICE IN ACCORDANCE WITH COB STANDARD DETAIL
660-3 (OR 660-5). CONTRACTOR SHALL PROVIDE NEW PIPING, AND ALL FITTINGS/PARTS
TO FACILITATE NEW WATER SERVICE INSTALLATION, ACCORDING TO THE STANDARD
DETAIL.
15. UPON ACCEPTANCE OF THE MAINS AND SERVICES, THE CONTRACTOR SHALL
COORDINATE FINAL SERVICE CONNECTIONS WITH CITY WATER DEPARTMENT. CITY
WATER DEPARTMENT WILL INSTALL THE NEW METER. A PRIVATE PLUMING PERMIT IS
REQUIRED FOR ALL WORK ON THE CUSTOMER SIDE OF NEW WATER METER
(BACKSIDE), AT CONTRACTOR'S EXPENSE.
16. THE CONTRACTOR SHALL PROVIDE INSTALL AND ADJUST THE NEW WATER METER BOX
TO FINAL LINE AND GRADE. REMOVE AND DISPOSE OF THE OLD METER BOX AND
OTHER EXCESS MATERIALS. COMPLETE LANDSCAPING RESTORATION, CURB
REPLACEMENT AND SIDEWALK AS REQUIRED.
TRAFFIC CONTROL NOTES
1. TRAFFIC CONTROL TO BE PERFORMED IN ACCORDANCE WITH THE MANUAL FOR UNIFORM TRAFFIC
CONTROL DEVICES AND OREGON AMENDMENTS AS REQUIRED. THE CITY CAN REQUIRE
ADDITIONAL TRAFFIC CONTROL MEASURES AS NEEDED TO PROVIDE FOR PUBLIC SAFETY.
2. ON RESIDENTIAL LOCAL STREETS, THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL
REQUIRED TRAFFIC CONTROL WHEN WORK IS BEING DONE IN THE RIGHT OF WAY.
3. ALL TRAFFIC CONTROL MEASURES NEED TO BE SUBMITTED TO THE CITY OF BEAVERTON FOR
REVIEW AT LEAST 5 (FIVE WORKING DAYS PRIOR TO CONSTRUCTION. ALL STREET CLOSURES
SHALL BE APPROVED BY THE CITY TRAFFIC ENGINEER, AT LEAST 5 (FIVE) WORKING DAYS IN
ADVANCE.
4. UPON APPROVAL, THE CONTRACTOR SHALL NOTIFY THE BEAVERTON POLICE DEPARTMENT,
TUALATIN VALLEY FIRE AND RESCUE AND THE BEAVERTON SCHOOL DISTRICT TRANSPORTATION
OFFICE AT LEAST 48 HOURS IN ADVANCE OF ANY STREET CLOSURE.
5. TRAFFIC CONTROL PLANS SHALL COMPLY WITH THE OREGON DEPARTMENT OF TRANSPORTATION
- "SHORT TERM TRAFFIC CONTROL HANDBOOK". TRAFFIC CONTROL DEVICES SHALL COMPLY WITH
THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" PREPARED BY THE FEDERAL HIGHWAY
ADMINISTRATION, LATEST REVISION. CONTRACTOR SHALL COMPLY WITH ALL CONDITIONS
SPECIFIED IN ROAD PERMITS ISSUED FOR THIS PROJECT.
6. CONTRACTOR SHALL COORDINATE ALL STREET AND SIDEWALK CLOSURES WITH THE CITY.
CONTRACTOR SHALL SUPPLY SIGNING AND BARRICADES AS REQUIRED TO ASSURE AUTOMOTIVE
AND PEDESTRIAN SAFETY.
GENERAL CONSTRUCTION NOTES
1. THE CONTRACTOR SHALL NOTIFY THE CITY INSPECTOR AT LEAST 48 HOURS (TWO FULL WORKING DAYS) PRIOR TO BEGINNING THE PROJECT. CONNECTIONS BETWEEN EXISTING INFRASTRUCTURE
AND NEW WORK SHALL NOT BE MADE UNTIL NECESSARY INSPECTIONS AND TESTS HAVE BEEN
COMPLETED ON THE NEW WORK AND IT IS FOUND TO CONFORM IN ALL RESPECTS TO THE
REQUIREMENTS OF THE PLANS AND SPECIFICATIONS.
2. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES WHERE
FACILITIES CROSS. CONTRACTOR SHALL POT HOLE EXISTING UTILITIES 200 FEET AHEAD OF
LAYING PIPE AT ALL CROSSINGS. IF CONFLICTS ARISE, THE CONTRACTOR SHALL NOTIFY THE
OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. UTILITY LOCATE ONE CALL #
1-800-332-2344
3. ALL CONSTRUCTION IS TO BE PERFORMED IN ACCORDANCE WITH THE MOST RECENT VERSION
OF CITY OF BEAVERTON STANDARDS, OREGON APWA/ODOT STANDARD SPECIFICATIONS, CLEAN
WATER SERVICES (CWS) STANDARDS (INCLUDING EROSION PREVENTION AND SEDIMENT
CONTROL) AND THE OREGON ADMINISTRATION RULES (OAR), CHAPTER 333, UNLESS NOTED ON
THE PLANS OR SPECIFIED OTHERWISE.
4. ALL EXISTING UTILITIES DISTURBED BY CONTRACTOR SHALL BE REPAIRED IMMEDIATELY AND THE
RESPECTIVE UTILITY COMPANY NOTIFIED OF THE DISTURBANCE WITHOUT DELAY.
5. CONTRACTOR SHALL SUBMIT "AS-BUILT" INFORMATION TO THE OWNER'S REPRESENTATIVE UPON
COMPLETION OF CONSTRUCTION.
6. THE CONTRACTOR SHALL NOT DAMAGE OR CUT EXISTING ASBESTOS CEMENT PIPE. EXCAVATE
AND EXPOSE EXISTING ASBESTOS CEMENT PIPE UNTIL APPROPRIATE JOINTS ARE EXPOSED.
DISCONNECT THE ASBESTOS CEMENT PIPE JOINT AND REMOVE THE APPROPRIATE SECTIONS OF
ASBESTOS CEMENT PIPE WITHOUT CUTTING OR DAMAGING THEM. DISPOSE OF REMOVED
ASBESTOS CEMENT PIPE IN A LEGAL MANNER AND IN CONFORMANCE WITH THE REQUIREMENTS
OF AUTHORITIES CONTROLLING AIR POLLUTION AND SOLID WASTE DISPOSAL. CONTRACTOR
SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF OREGON REVISED STATUTES (ORS)
468A.700 THROUGH 468A-760.
7. FINAL LOCATIONS OF ALL VALVES AND VALVE BOXES, FIRE HYDRANTS, AIR RELEASE ASSEMBLIES, SERVICE CONNECTION CORP STOPS, DRIVEWAY APRONS, SEWER LATERALS, PERMANENT SIGNS, AND CATCH BASINS SHALL BE FIELD LOCATED. THE CONTRACTOR SHALL COORDINATE FINAL
LOCATIONS OF THE DESCRIBED ITEMS WITH THE OWNER'S REPRESENTATIVE.
8. UTILITY CONSTRUCTION SEQUENCING WILL BE REQUIRED IN ORDER TO PREVENT CONFLICTS
WITH EXISTING UTILITIES REMAINING IN SERVICE UNTIL NEWLY INSTALLED UTILITIES ARE
CONNECTED AND IN SERVICE. CONTRACTOR SHALL SEQUENCE UTILITY WORK INCLUDING
TEMPORARY CONNECTIONS AND BYPASSES AS REQUIRED SUCH AS TO MINIMIZE DISRUPTION OF
SERVICES. SEE SECTION 105.4.01 WITHIN THE SPECIFICATIONS REGARDING CONSTRUCTION
SEQUENCING REQUIREMENTS FOR THIS PROJECT.
9. MAINTENANCE OF THE WORK AREA AND APPROACH ROADS IS THE RESPONSIBILITY OF THE
CONTRACTOR. THE WORK AREA AND APPROACH ROADS SHALL BE MAINTAINED IN A CLEAN
CONDITION, FREE FROM OBSTRUCTIONS AND HAZARDS.
10. ANY CHANGE IN CONSTRUCTION AFTER PLAN APPROVAL MUST BE SUBMITTED IN WRITING AND
APPROVED BY THE CITY PRIOR TO CHANGE.
11. AT THE END OF EACH WORK DAY ALL TRENCHES SHALL BE BACKFILLED AND ALL TRENCHES
WITHIN STREETS SHALL BE TEMPORARY PAVED OR COVERED TO THE SATISFACTION OF THE
OWNER'S REPRESENTATIVE. STEEL SHEET PLACEMENTS SHALL BE LIMITED TO 36 HOURS IN ANY
ONE LOCATION. BEYOND 36 HOURS, EXCAVATIONS SHALL BE PAVED. AC PAVEMENT EITHER
TEMPORARY OR PERMANENT, SHALL BE HOT MIX BITUMINOUS ASPHALT. NO TRENCH, ON-SITE OR
OFF-SITE, SHALL BE LEFT AT ANY TIME IN AN UNSAFE CONDITION. THE CONTRACTOR IS
RESPONSIBLE FOR AND IS LIABLE FOR HAZARDS OR DAMAGE RESULTING FROM THE
PROSECUTION OF THE WORK.
12. EFFECTIVE EROSION PREVENTION & SEDIMENT CONTROL, DUST CONTROL, AND DRAINAGE
CONTROL IS REQUIRED AT ALL TIMES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
PROTECTION OF ALL WORK, ADJACENT PROPERTIES AND DOWNSTREAM FACILITIES FROM
EROSION AND SILTATION DURING THE COURSE OF THE WORK. ANY DAMAGE RESULTING FROM
SUCH EROSION AND SILTATION SHALL BE CORRECTED AT THE SOLE EXPENSE OF THE
CONTRACTOR.
13. THE CONTRACTOR SHALL MAINTAIN ACCESS TO ALL DRIVEWAYS. IF A DRIVEWAY MUST BE
BLOCKED, THE CONTRACTOR SHALL GIVE THE HOMEOWNER, APARTMENT MANAGER AND/OR
BUILDING OWNER 24 HOURS NOTICE AND SHALL ENSURE ACCESS TO DRIVEWAYS AT THE END OF
EACH WORK DAY.
14. THE CONTRACTOR SHALL EXERCISE ALL DUE CARE IN PROTECTING PROPERTY ALONG THE
ROUTE OF THE IMPROVEMENTS. THIS PROTECTION SHALL INCLUDE, BUT NOT BE LIMITED TO,
TREES, YARDS, FENCES, DRAINAGE LINES, MAIL BOXES, DRIVEWAYS, SHRUBS, LAWNS,
IRRIGATION SYSTEMS, WITHIN ANY RIGHTS-OF-WAYS AND EASEMENTS. IF ANY OF THE ABOVE
HAVE BEEN DISTURBED, THEY SHALL BE RESTORED AS NECESSARY TO AS NEAR THEIR ORIGINAL
CONDITION AS POSSIBLE OR REPLACED IN KIND.
15. ALL SURVEY MONUMENTS SHALL BE LOCATED AND PROTECTED, EXCEPT AS SPECIFICALLY
DIRECTED BY THE CITY ENGINEER.
16. THE CONTRACTOR SHALL PERFORM ALL THE WORK SHOWN ON THE DRAWINGS AND ALL
INCIDENTAL WORK CONSIDERED NECESSARY TO COMPLETE THE PROJECT IN AN ACCEPTABLE
MANNER.
17. THE CONTRACTOR AND OR SUB-CONTRACTOR SHALL HAVE A MINIMUM OF ONE SET OF CITY
APPROVED CONSTRUCTION PLANS ON THE JOB SITE AT ALL TIMES DURING EACH CONSTRUCTION
PHASE WHILE WORK IS BEING DONE.
18. ALL MATERIAL SUPPLIERS SHALL SUBMIT TO THE ENGINEER PROOF OF MATERIAL(S) TESTED IN
ACCORDANCE WITH SPECIFICATIONS. BY ACCEPTANCE OF THE CONTRACT WITH THE
OWNER/DEVELOPER, THE CONTRACTOR CERTIFIES THAT ALL MATERIALS DELIVERED TO THE JOB SITE WILL MEET OR EXCEED THOSE SPECIFICATIONS. ANY MATERIAL NOT CONFORMING SHALL BE
REMOVED FROM THE SITE AT NO ADDITIONAL COST TO THE OWNER.
19. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL LEAVE THE PROJECT AREA FREE OF
DEBRIS AND UNUSED MATERIALS.
THIS DESIGN COMPLIES WITH ORS 92.044 (7) IN THAT NO UTILITY INFRASTRUCTURE IS DESIGNED TO BE WITHIN ONE FOOT OF A SURVEY MONUMENT LOCATION SHOWN ON A SUBDIVISION OR PARTITION PLAT. NO DESIGN MODIFICATION NOR FINAL FIELD LOCATION CHANGE SHALL BE PERMITTED IF IT
WOULD CAUSE ANY UTILITY INFRASTRUCTURE TO BE PLACED WITHIN THE PROHIBITED AREA.
EROSION PREVENTION & SEDIMENT CONTROL STANDARD NOTES
1. APPROVAL OF THIS EROSION PREVENTION & SEDIMENTATION CONTROL (ESC) PLAN DOES NOT
CONSTITUTE AN APPROVAL OF PERMANENT ROAD OR DRAINAGE DESIGN (E.G. SIZE AND
LOCATION OF ROADS, PIPES, RESTRICTORS, CHANNELS, RETENTION FACILITIES, UTILITIES, ETC.).
2. THE IMPLEMENTATION OF THESE ESC PLANS AND THE CONSTRUCTION, MAINTENANCE,
REPLACEMENT, AND UPGRADING OF THESE ESC FACILITIES IS THE RESPONSIBILITY OF THE
APPLICANT/CONTRACTOR UNTIL ALL CONSTRUCTION IS COMPLETED AND APPROVED AND
VEGETATION/LANDSCAPING IS ESTABLISHED.
3. THE ESC FACILITIES SHOWN ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION WITH ALL
CLEARING AND GRADING ACTIVITIES, AND IN SUCH A MANNER AS TO INSURE THAT SEDIMENT
LADEN WATER DOES NOT ENTER THE DRAINAGE SYSTEM OR VIOLATE APPLICABLE WATER
STANDARDS.
4. THE ESC FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR ANTICIPATED
SITE CONDITIONS. DURING THE CONSTRUCTION PERIOD, THESE ESC FACILITIES SHALL BE
UPGRADED AS NEEDED FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT
SEDIMENT-LADEN WATER DOES NOT LEAVE THE SITE.
5. THE ESC FACILITIES SHALL BE INSPECTED DAILY BY THE APPLICANT/CONTRACTOR AND
MAINTAINED AS NECESSARY TO ENSURE THEIR CONTINUED FUNCTIONING.
6. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF
ONCE A MONTH OR WITHIN THE 24 HOURS FOLLOWING A STORM EVENT.
7. AT NO TIME SHALL MORE THAN ONE FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A TRAPPED CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR
TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT LADEN WATER INTO THE
DOWNSTREAM SYSTEM.
8. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF
CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES
MAY BE REQUIRED TO INSURE THAT ALL PAVED AREAS ARE KEPT CLEAN FOR THE DURATION OF
THE PROJECT.
WATERLINE - SEWERLINE SEPARATION:
ZONE 1: PARALLEL WATERLINES OK. CROSSING RESTRICTIONS ONLY
ZONE 2: NOT ALLOWED (UNLESS SPECIAL PERMISSION FROM OHA) AND CITY ENGINEER
ZONE 3: PARALLEL WATERLINES PROHIBITED
ZONE 4: PARALLEL WATERLINES PROHIBITED
SEE OAR CHAPTER 333 FOR FULL NOTES ON WATERLINE REQUIREMENTS.
CROSSINGS NOTES:
1. WHEREVER POSSIBLE, THE BOTTOM OF THE WATER LINE SHALL BE 1.5' OR MORE ABOVE THE TOP OF
THE SEWER AND ONE FULL LENGTH OF THE WATERLINE CENTERED AT THE CROSSINGS.
2. WHERE THE WATER LINE CROSSES OVER THE SEWER LINE BUT WITH A CLEARANCE OF LESS THAN 1.5
FEET: CENTER ONE LENGTH OF THE WATER LINE AT THE CROSSING AND THE SEWER LINE SHALL BE REPLACED WITH A FULL LENGTH OF PIPE CENTERED AT THE CROSSING POINT WITH C900, HDPE SDR 17, CLASS 52 DIP A MINIMUM OF 9' ON BOTH SIDES OF THE CROSSINGS.
3. WHERE THE WATER LINE CROSSES UNDER THE SEWER LINE: CENTER ONE LENGTH OF THE WATER LINE AT THE CROSSING AND THE SEWER LINE SHALL BE REPLACED WITH A FULL LENGTH OF PIPE CENTERED AT THE CROSSING POINT WITH C900, HDPE SDR 17, CLASS 52 DIP A MINIMUM OF 9' ON BOTH
SIDES OF THE CROSSINGS. BACKFILL IN THIS AREA SHALL BE 100 PSI CLSM.
17. PRIOR TO TIE-IN, THE CONTRACTOR SHALL INSTALL TEMPORARY BLOW-OFF ASSEMBLIES FOR
PRESSURE TESTING AND CHLORINATION. ALL NEW WATER MAINS SHALL BE PRESSURE TESTED
AND DISINFECTED BEFORE CONNECTION TO THE EXISTING SYSTEM AND BEFORE ANY SERVICE
CONNECTIONS ARE MADE. PROVIDE 1" TEMPORARY TAPS FOR THE CHLORINATION INJECTION AS
REQUIRED. PLUG TEMPORARY TAPS WITH BRASS PLUG UPON ACCEPTANCE OF NEW WATERLINE.
18. UPON COMPLETION OF INSTALLATION OF THE WATER SYSTEM, ALL LINES SHALL BE FLUSHED AND
DISINFECTED IN CONFORMANCE WITH OREGON HEALTH DIVISION GUIDELINES AND THE
REQUIREMENTS OF THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY. WATERLINES
SHALL BE PRESSURE TESTED FOLLOWING COMPLETION. THE MINIMUM TEST PRESSURE SHALL BE
150 PSI. FOR LINES WORKING WITH OPERATION PRESSURES GREATER THAN 100 PSI, THE
MINIMUM TEST PRESSURE SHALL BE ONE AND ONE-HALF TIMES THE DESIGN OPERATION
PRESSURE. ALLOWABLE LEAKAGE IS 0 PSI.
19. THE CONTRACTOR SHALL DISPOSE OF THE SUPERCHLORINATED WATER IN AN APPROVED
MANNER. DO NOT ALLOW DISINFECT ION WATER TO FLOW INTO A WATERWAY WITHOUT
ADEQUATE DILUTION OR OTHER SATISFACTORY METHODS OF REDUCING CHLORINE RESIDUALS
TO A SAFE LEVEL AS MANDATED BY DEQ.
20. THERE MAY BE SHORT SECTIONS OF THE PIPE LINE THAT CONNECT TO THE EXISTING SYSTEM
THAT ARE DIFFICULT TO CHLORINATE. THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR
SHALL IDENTIFY THESE SHORT SECTIONS OF PIPELINE AND AN ALTERNATIVE METHOD OF
DISINFECT ION EMPLOYED. APPLICATION OF 300mn/l CHLORINE SOLUTION SHALL BE APPLIED BY
SOAKING IN CONTAINER APPROVED BY OWNER'S REPRESENTATIVE. THE CHLORINE SOLUTION
SHALL REMAIN FOR THREE HOURS BEFORE FLUSHING. ALL SWABBING / SOAKING ACTIVITIES TO
BE DONE WITH CITY WATER REPRESENTATIVE PRESENT.
21. CONTRACTOR SHALL PROTECT WATER PIPE ENDS FROM CONTAMINATED WATER AND DEBRIS AT
ALL TIMES. CONTRACTOR SHALL CAP AND /OR COVER PIPE ENDS AT THE END OF EACH WORK
DAY.
22. WHENEVER THE WATERLINE OR SERVICES CROSS GAS LINES WITHIN 6" INSTALL A FIBERGLASS
SHEATHING MATERIAL PROVIDED BY NW NATURAL OR HALF A SECTION OF PVC PIPE BETWEEN
THE GAS LINE AND THE WATERLINE FOR A DISTANCE OF 18" ON EACH SIDE OF THE GAS LINE.
SHEET 4 SHEET 5 SHEET 6
SHEET 7
SH
EE
T
SH
EE
T
SH
EE
T
SH
EE
T
SHEET 12
SHEET 13
SHEET 14
SHEET 15
SHEET 16
ALIGNMENT KEY
ALIGNMENT # SHEET #
A 4 - 11 B 12 - 13 C 14 D 15 E 16
OAR CHAPTER 333 CROSSING- SANITARY SEWER AND WATERLINES NOTES
AutoCAD SHX Text
ZONE 2
AutoCAD SHX Text
ZONE 2
AutoCAD SHX Text
ZONE 4
AutoCAD SHX Text
ZONE 4
AutoCAD SHX Text
ZONE 1
AutoCAD SHX Text
ZONE 1
AutoCAD SHX Text
ZONE 3
AutoCAD SHX Text
ZONE 4
AutoCAD SHX Text 5.0'
AutoCAD SHX Text 10.0'
AutoCAD SHX Text
EX GROUND
EX SEWER MAIN OR LATERAL
S
D
DD
58" COVER
36" COVER 36" COVER
60" COVER
36" COVER
SW HART RD
SW
TH
A
VE
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VE
M
EN
TS
C
IP
SW
H
A R
T R
D T
R A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+8
TO
S
TA
+7
ERRBDN
SCALE
EROSION CONTROL NOTES
12'
WATER NOTES
PLAN
PROFILE
SCALE: 1"=5' V
SH
EET 5
M
ATC
H
LIN
E STA: 2+75
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text 12980
AutoCAD SHX Text 12960
AutoCAD SHX Text
WM
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
10" DI
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
10" CI
AutoCAD SHX Text
410' NEXT VALVE
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
18" SD
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
12980 SW HART RD
AutoCAD SHX Text 36198685
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
12960 SW HART RD
AutoCAD SHX Text 36279522
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 175' OF CL 52 12" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. CONNECT TO EXISTING 1O" WATER MAIN VIA 10" HOT TAP W/ THRUST BLOCK PER C.O.B. ENGINEERING STANDARD DRAWING 630-2, SEE SHEET 24. SEE CONNECTION DETAIL 1, SEE SHEET 17. INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. REPAIR EXISTING SPEED HUMP TO CONFORM TO ORIGINAL PARABOLIC GEOMETRY. CONTRACTOR TO INSTALL SHEATHING MATERIAL PROVIDED BY NW NATURAL BETWEEN EX GAS LINE & NEW WATERLINE, 18" EA SIDE XING, TYP. INSTALL 1" CARV PER C.O.B. ENGINEERING STANDARD DRAWING 640-5, SEE SHEET 26. INSTALL 12" - 11.25° VERTICAL BEND, MJ.ABANDON EXISTING WATER MAIN, TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
36" COVER
36" COVER 74" COVER
74" COVER
18" MIN.
N
SCALE
SW HART RD
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+7
TO
S
TA
+5
ERRBD
EROSION CONTROL NOTES
SH
EET 6
M
ATC
H
LIN
E STA: 4+50
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
+7
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
12'
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text 12950
AutoCAD SHX Text 12940
AutoCAD SHX Text 12850
AutoCAD SHX Text 12945
AutoCAD SHX Text 12925
AutoCAD SHX Text
WM
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
4" DI
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
10" DI
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 175' OF CL 52 12" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 12" x 6" TEE, MJ, W/ 6" RSGV, MJ & HYDRANT ASSEMBLY PER C.O.B ENGINEERING STANDARD DRAWING 650-2, SEE SHEET 27, TYP. REMOVE EXISTING FIRE HYDRANT AND ASSEMBLY, PLUG PIPE AND ABANDON IN PLACE, TYP. INSTALL 12" - 22.5° HORIZONTAL BEND, MJ.INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. ABANDON EXISTING WATER MAIN, TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
12950 SW HART RD
AutoCAD SHX Text 36198685
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
12940 SW HART RD
AutoCAD SHX Text 36279522
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
12945 SW HART RD
AutoCAD SHX Text 36279522
AutoCAD SHX Text
29 FT
AutoCAD SHX Text
12850 SW HART RD
AutoCAD SHX Text 36279522
AutoCAD SHX Text
10 FT
AutoCAD SHX Text
12925 SW HART RD
AutoCAD SHX Text 36279522
AutoCAD SHX Text
30 FT
AutoCAD SHX Text
12905 SW HART RD
AutoCAD SHX Text 48860981
AutoCAD SHX Text
30 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
36" COVER
36" COVER
32" COVER
64" COVER
T
N
SCALE
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+5
TO
S
TA
+2
ERRBD
EROSION CONTROL NOTES
WATER NOTES
PROFILE
SCALE: 1"=5' V
SW HART RD
SH
EET 7
M
ATC
H
LIN
E STA: 6+25
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
+5
PLAN
SW
HART RD
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text
WM
AutoCAD SHX Text 12830
AutoCAD SHX Text 12810
AutoCAD SHX Text
WM
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 162' OF CL 52 12" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 13' OF CL 52" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 12" - 11.25° HORIZONTAL BEND, MJ.INSTALL 12" RSGV, MJ. INSTALL 12" TEE, MJ. INSTALL 12" x 8" REDUCER, MJ. INSTALL 8" x 6" TEE, MJ. INSTALL 8" RSGV, MJ. INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. CONTRACTOR TO INSTALL SHEATHING MATERIAL PROVIDED BY NW NAT. BETWEEN EX GAS LINE & NEW WATERLINE, 18" EA SIDE XING, TYP. INSTALL 1" CARV PER C.O.B. ENGR STD DWG 640-5, SEE SHEET 26. INSTALL 12" - 11.25° VERTICAL BEND, MJ.ABANDON EXISTING WATER MAIN, TYP. EXERCISE CAUTION AROUND DUCT BANKS; ANY DAMAGE SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
12830 SW HART RD
AutoCAD SHX Text 87862744
AutoCAD SHX Text
10 FT
AutoCAD SHX Text
12810 SW HART RD
AutoCAD SHX Text 83103239
AutoCAD SHX Text
63 FT
AutoCAD SHX Text
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
NEW 12" DI SEE SHEET 12
AutoCAD SHX Text
NEW 8" DI SEE SHEET 14
AutoCAD SHX Text
10" DI
AutoCAD SHX Text
12" SD
AutoCAD SHX Text
4" CI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
36" COVER
46" COVER
36" COVER
N
SCALE
SW JUNIPER TER
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+2
TO
S
TA
+7
ERRBD
SW
S
O
RR
EN
TO
R D
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
+2
SHEET 8
M
ATCH LINE STA: 7+75
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text 12845
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 150' OF CL 52 8" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 8" - 11.25° HORIZONTAL BEND, MJ.INSTALL 8" - 22.5° HORIZONTAL BEND, MJ.INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. INSTALL 8" x 6" TEE, MJ, W/ 6" RSGV, MJ & HYDRANT ASSEMBLY PER C.O.B ENGINEERING STANDARD DRAWING 650-2, SEE SHEET 27, TYP. REMOVE EXISTING FIRE HYDRANT AND ASSEMBLY, PLUG PIPE AND ABANDON IN PLACE, TYP. ABANDON EXISTING WATER MAIN, TYP. RESTORE SURFACE OF LANDSCAPE ISLAND WITH EARTH-COVERED 3" LAYER OF DOUG FIR BARK MULCH AFTER CONSTRUCTION AND ACCEPTANCE OF NEW WATERLINE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
12845 SW HART PL
AutoCAD SHX Text 36279522
AutoCAD SHX Text
12 FT
AutoCAD SHX Text
7295 SW JUNIPER TER
AutoCAD SHX Text 44325941
AutoCAD SHX Text
36 FT
AutoCAD SHX Text
7265 SW JUNIPER TER
AutoCAD SHX Text 22054709
AutoCAD SHX Text
36 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
46" COVER
36" COVER
36" COVER
N
SCALE
SW JUNIPER TER
SH
EE
T
M
AT
C
H L
IN
E
ST
A:
+7
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+7
TO
S
TA
+7
ERRBD
9.9'
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
SH
EET 9
M
ATC
H
LIN
E STA: 8+75
8" SAN SWR >7' DEEP
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
NEW 4" DI SEE SHEET 16
AutoCAD SHX Text
4" CI
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 100' OF CL 52 8" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 8" x 4" TEE, MJ. INSTALL 8" RSGV, MJ. INSTALL 4" RSGV, MJ. ABANDON EXISTING WATER MAIN, TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
36" COVER
36" COVER
N
SCALE
SW JUNIPER TER
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
+7
TO
S
TA
0+
ERRBD
EROSION CONTROL NOTES
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
+7
WATER NOTES
8'
PROFILE
SCALE: 1"=5' V
PLAN
SH
EET 10
M
ATC
H
LIN
E STA: 10+25
8" SAN SWR > 8' DEEP
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
12" SD
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 150' OF CL 52 8" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. ABANDON EXISTING WATER MAIN, TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
7225 SW JUNIPER TER
AutoCAD SHX Text 46936
AutoCAD SHX Text
15 FT
AutoCAD SHX Text
7195 SW JUNIPER TER
AutoCAD SHX Text 20412417
AutoCAD SHX Text
16 FT
AutoCAD SHX Text
15" SD
AutoCAD SHX Text
AutoCAD SHX Text
36" COVER
36" COVER
N
SCALE
SW JUNIPER TER
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
0+
T
O S
TA
2+
ERRBD
EROSION CONTROL NOTES
SW
27TH ST
WATER NOTES
8.7'
PROFILE
SCALE: 1"=5' V
PLAN
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
0+
SH
EET 11
M
ATC
H
LIN
E STA: 12+00
23.7'
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
NEW 8" DI SEE SHEET 15
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
15" SD
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 175' OF CL 52 8" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 8" - 11.25° HORIZONTAL BEND, MJ.INSTALL 8" TEE, MJ. INSTALL 8" RSGV, MJ. INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. ABANDON EXISTING WATER MAIN, TYP. CONTRACTOR TO INSTALL SHEATHING MATERIAL PROVIDED BY NW NATURAL BETWEEN EX GAS LINE & NEW WATERLINE, 18" EA SIDE XING, TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
7165 SW JUNIPER TER
AutoCAD SHX Text 29541125
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
7145 SW JUNIPER TER
AutoCAD SHX Text 47782195
AutoCAD SHX Text
14 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COM
M
S
S
50" COVER
31" COVER
36" COVER
36" COVER
N
SCALE
SW JUNIPER TER
SH
EE
T
M
AT
C H
L
IN
E
ST
A:
2+
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
A
PL
A N
P
R O
FI
LE
S
TA
2+
T
O S
TA
3+
ERRBD
EROSION CONTROL NOTES
SW
D
AL
E
AV
E
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
14+00
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
EX 8"
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 8" DI
AutoCAD SHX Text
110' NEXT VALVE
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
8" CI
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
8" SAN
AutoCAD SHX Text
6" CI
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 198' OF CL 52 8" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 8" - 11.25° HORIZONTAL BEND, MJ.INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. ABANDON EXISTING WATER MAIN, TYP. CONNECT TO EXISTING 8" WATER MAIN, SEE CONNECTION DETAIL 2, SEE SHEET 18. DEPTH TO BE VERIFIED BY CONTRACTOR.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WATER SERVICE TABLE
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
EX. WM #
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
7125 SW JUNIPER TER
AutoCAD SHX Text 35067288
AutoCAD SHX Text
15 FT
AutoCAD SHX Text
7095 SW JUNIPER TER
AutoCAD SHX Text 34862049
AutoCAD SHX Text
15 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
4" LAT
AutoCAD SHX Text
T
59" COVER
81" COVER
N
SCALE
SW HART RD
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
B
PL
A N
P
R O
FI
LE
S
TA
+8
TO
S
TA
+5
ERRBD
EROSION CONTROL NOTES
SW
J
UN
IP
ER
TE
R SHEET 13
M
ATCH LINE STA: 2+50
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
TL
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
NEW 8" DI SEE SHEET 7
AutoCAD SHX Text
NEW 12" DI SEE SHEET 6
AutoCAD SHX Text
NEW 8" DI SHEET 14
AutoCAD SHX Text
10" DI
AutoCAD SHX Text
12" SD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 150' OF CL 52 12" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 12" TEE, MJ. INSTALL 12" RSGV, MJ. INSTALL 12" - 22.5° HORIZONTAL BEND, MJ.RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. REMOVE & REINSTALL TRAFFIC SIGN, TYP. ABANDON EXISTING WATER MAIN, TYP. REMOVE EXISTING TREE, INCLUDING ROOTS, AS NECESSARY FOR WATERLINE INSTALLATION. FOR EXCAVATION WITHIN TREE DRIP LINE USE PNEUMATIC AIR GUN, VACTOR, OR APPROVED EQUIVALENT IN ORDER TO PROTECT TREE AND TREE ROOTS GREATER THAN 1.5 INCHES PER CITY ARBORIST AND SPECIAL PROVISIONS. INSTALL TREE PROTECTION FENCING AS REQUIRED OR INSTRUCTED. CONTRACTOR SHALL FURNISH AND INSTALL (3) VANDERWOLF'S PYRAMID LIMBER PINE (PINUS FLEXILIS), IN ACCORDANCE WITH CITY OF BEAVERTON DETAIL 4040, ENSURING PROPER SOIL PREPARATION, STAKING, MULCHING, AND INITIAL WATERING TO ESTABLISH HEALTHY GROWTH. LOCATIONS TO BE CONFIRMED BY CITY ARBORIST. RESTORE SURFACE OF LANDSCAPE ISLAND WITH EARTH-COVERED 3" LAYERED OF DOUG FIR BARK MULCH AFTER CONSTRUCTION AND ACCEPTANCE OF NEW WATERLINE. EXERCISE CAUTION AROUND DUCT BANKS; ANY DAMAGE SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
S/////
34" COVER
81" COVER
71" COVER
N
SCALE
SW HART RD
SHEET #
CIP PROJ #
CheckedDrawn
PLOT DATE: 12/11/2025
H:\CIP\4211 - HART RD TRAFFIC CIR - WATER - 2021\CAD\ALEE\CIP 4211 HART RD TRAFFIC CIRCLE FINAL V4.DWG
D
AT
E R
EV
IS
IO
N
BY
AP
R
VD
PH
O N
E:
(5
) 5
-2
SW
M
IL
LI
KA
N W
AY
BE
AV
ER
TO
N , O
R
S
ET
DRRERR
W A
TE
R
LI
N
E
IM
PR
O
VM
EN
TS
C
IP
SW
H A
R T
R D
T R
A
FF
IC
C
IR
C
LE
PR
O
PO
SE
D A
LI
G
N M
EN
T
B
PL
A N
P
R O
FI
LE
S
TA
+5
TO
S
TA
+5
ERRBD
EROSION CONTROL NOTES
SW SORRENTO RD
WATER NOTES
PROFILE
SCALE: 1"=5' V
PLAN
SH
EE
T
M
AT
CH
L
IN
E
ST
A:
+5
AutoCAD SHX Text
WM
AutoCAD SHX Text
WM
AutoCAD SHX Text 12825
AutoCAD SHX Text
WM
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
EX 16"
AutoCAD SHX Text
FULLY RESTRAINED, CLASS B GRANULAR BACKFILL
AutoCAD SHX Text
NEW 12" DI
AutoCAD SHX Text
TRENCH
AutoCAD SHX Text
ABANDON
AutoCAD SHX Text
AutoCAD SHX Text INSTALL INLET SEDIMENT CONTROL DEVICE @ CB OPENING, NO INTERNAL OVERFLOW ALLOWED. SEE INLET SEDIMENT CONTROL DETAILS ON SHEETS 31 & 32.
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 113' OF CL 52 12" DI WATER MAIN, FULLY RESTRAINED, ZINC COATED W/ POLY WRAP, CLASS B GRANULAR BACKFILL, TYP. INSTALL 12" - 22.5° HORIZONTAL BEND, MJ.INSTALL 12" - 11.25 VERTICAL BEND, MJ. INSTALL 12" - 45° HORIZONTAL BEND, MJ.INSTALL 1" DOMESTIC WATER SERVICE PER C.O.B. ENGINEERING STANDARD DRAWING 660-3. SEE SHEET 28, TYP. REMOVE EXISTING WATER METER AND ABANDON EXISTING SERVICE LINE PER C.O.B. ENGINEERING STANDARD DRAWING 660-1, SEE SHEET 28, TYP. CONNECT NEW SERVICE LINE TO EXISTING, SEE WATER SERVICE CONNECTION DETAIL, SEE SHEET 33, TYP. INSTALL 1" CARV PER C.O.B. ENGINEERING STANDARD DRAWING 640-5, SEE SHEET 26. REMOVE & REPLACE EX SIDEWALK WHERE DISTURBED PER C.O.B. ENGINEERING STANDARD DRAWING 2040, SEE SHEET 22, TYP. RESTORE GROUND COVER/LANDSCAPING TO MATCH SURROUNDING, TYP. REMOVE & REPLACE CURB & GUTTER PER C.O.B. ENGINEERING STANDARD DRAWING 2020, SEE SHEET 22, TYP. CONNECT TO EXISTING 16" WATER MAIN, SEE CONNECTION DETAIL 3, SEE SHEET 19. ABANDON EXISTING WATER MAIN, SEE ABANDONMENT DETAIL SHEET 21. EXERCISE CAUTION AROUND DUCT BANKS; ANY DAMAGE SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .