CFTOD_TWO01_100 PLANS_ECD OH TRUSS_2026-04-16.pdf
PDF 6 MB Posted
- Attached to
- 2027 Overhead Sign Structure Replacements
- Solicitation number
- 147862
- Issued by
- Polk County, Florida
About this file
This is a 100% design submittal document for the ECD Truss Replacement project, prepared by TLP Engineering Consultants, Inc. for the Central Florida Tourism Oversight District (CFTOD) in Lake Buena Vista, Florida. The project involves the replacement of two overhead sign structures (OT-1 and OT-2) on Epcot Center Drive. OT-1 is a full-span sign structure located at Station 19+00.73 with dimensions of 67 feet in length and 26 feet 4 inches in height, while OT-2 is positioned at Station 25+82.76 with dimensions of 75 feet in length and 22 feet 6 inches in height. The design includes comprehensive engineering plans for sign structure installation, geotechnical analysis based on standard penetration testing, traffic control and detour planning, and utility coordination. The plans are sealed and approved by licensed professional engineers Stephen W. Dickison (License No. 56129), David Michael Waddell (License No. 37382), and Craig G. Ballock (License No. 71571), with a submission date of April 15-16, 2026.
The project requires the contractor to coordinate closely with CFTOD personnel, Reedy Creek Energy Services, and other utility providers for electrical, irrigation, landscape, fiber optic, and smart city telecom installations. The contractor is responsible for implementing erosion control measures, maintaining traffic control devices in accordance with FDOT standards and the Manual of Uniform Traffic Control Devices, and preparing detailed maintenance of traffic (MOT) plans. Road closures on Epcot Center Drive are permitted only between 2 hours after the latest park closure until 6 a.m., with all closure requests requiring a minimum two-week advance notice. The existing sign truss foundations must be removed to 4 feet below existing grade, and all removed materials shall be disposed of by the contractor off CFTOD property. Work within 50 feet of the monorail beam requires an observer and adherence to monorail proximity guidelines. The project includes two drilled shaft foundation designs based on soil conditions identified through borings at each sign structure location, with design wind speeds of 150 mph and consideration of dense sand layers and potential artesian pressure conditions.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
Lake Buena Vista, Florida
Oversight District (CFTOD)
Central Florida Tourism
INTERSTATE
N.T.S.
KINGDOM
MAGIC
EPCOT
STUDIOS
HOLLYWOOD
KINGDOM
ANIMAL
DISNEY'S
N.T.S.
INSERT
SEE
INSERT
DWG NO. DESCRIPTION
PROJECT
LOCATION
ECD TRUSS REPLACEMENT
S-1
INDEX OF DRAWINGS
T I T
L E
A N
D I
N D
E X
O F
D R
A W
I N
G S
SIGNING AND PAVEMENT MARKING
100% SUBMITTAL
S-13 - S-15
S-12
S-10 - S-11
S-9
S-7 - S-8
S-5 - S-6
S-4
S-3
S-2
S-1
DETOUR PLAN
MOT NOTES
SIGN STRUCTURES
REPORT OF SPT BORINGS FOR
SIGN STRUCTURE DATA TABLES
SIGN STRUCTURE CROSS SECTIONS
SIGN STRUCTURE PLAN
PROJECT CONTROL
GENERAL NOTES
SIGNATURE SHEET
TITLE AND INDEX OF DRAWINGS
DRIV
E
EP
COT
CENTER
W O
R L
D
R
IV
E
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\KEYSSP01.dgn2:39:49 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
KEY [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A .C
License No. 56129
Professional Engineer
State of Florida
Stephen W. Dickison
APRIL, 2026
E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\SIGNSP01.dgn2:39:51 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SIGNATURESHEETS
State of Florida
Stephen W. Dickison
SHEET DESCRIPTIONSHEET NO.
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
ON ANY ELECTRONIC COPIES.
SIGNATURE MUST BE VERIFIED
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY
THIS ITEM HAS BEEN DIGITALLY
STATE OF
No 56129
R E
E
NI
GNE LANOIS
SE
F O
R P
ESNECIL
ADIROL
F
N
OSI
KCID .W NEHPE
T
S
STEPHEN W. DICKISON, P.E. NO. 56129
ORLANDO, FLORIDA 32801
450 SOUTH ORANGE AVENUE, SUITE 600
TLP ENGINEERING CONSULTANTS, INC.
SHEET DESCRIPTIONSHEET NO.
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
ON ANY ELECTRONIC COPIES.
SIGNATURE MUST BE VERIFIED
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY
THIS ITEM HAS BEEN DIGITALLY
STATE OF
No 37382
R E
E
NI
GNE LANOIS
SE
F O
R P
ESNECIL
ADIROL
F
L L
E D
DAW LEAHCIM
DI
V A
D
DAVID MICHAEL WADDELL, P.E. NO. 37382
ORLANDO, FLORIDA 32801
450 SOUTH ORANGE AVENUE, SUITE 600
TLP ENGINEERING CONSULTANTS, INC.
SIGN STRUCTURE DATA TABLE
SIGNATURE SHEET
S-9
S-2
DETOUR PLAN
MOT NOTES
SIGN STRUCTURE CROSS SECTIONS
SIGN STRUCTURE PLAN
PROJECT CONTROL
GENERAL NOTES
SIGNATURE SHEET
TITLE AND INDEX OF DRAWINGS
S-13, S-14, S-15
S-12
S-7, S-8
S-5, S-6
S-4
S-3
S-2
S-1
S
IG
N A
T U
R E
S H
E E
T
SHEET DESCRIPTIONSHEET NO.
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
ON ANY ELECTRONIC COPIES.
SIGNATURE MUST BE VERIFIED
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY
THIS ITEM HAS BEEN DIGITALLY
CRAIG G. BALLOCK, P.E. NO. 71571
ORLANDO, FLORIDA 32814
919 LAKE BALDWIN LANE
GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS, INC.
REPORT OF SPT BORINGS FOR SIGN STRUCTURES
SIGNATURE SHEET
S-10, S-11
S-2
S-2
STATE OF
No 71571
ESNECIL
KCOLL
AB .G GIAR
C
R E
E
NIGNE LANOIS
SEF
O R
P
ADIROL
F
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/16/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\GNNTSP01.dgn9:14:42 AM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SHEET-1 [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
State of Florida
Stephen W. Dickison
GENERAL NOTES
ADDITIONAL MEASURES PER DIRECTION FROM CFTOD PERSONNEL.
CONTROL DEVICES, DAILY INSPECTIONS AND MAINTENANCE OF DEVICES THROUGHOUT CONSTRUCTION. THE CONTRACTOR IS ALSO RESPONSIBLE FOR ANY
18. EROSION CONTROL DEVICES HAVE BEEN IDENTIFIED ON THE CONSTRUCTION PLANS. THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING ALL EROSION
FROM MONORAIL OPERATIONS PRESENT. REFER TO THE MONORAIL PROXIMITY GUIDELINES FOR MORE INFORMATION.
FIELD AND MARK WITH SILT FENCE FOR VISIBILITY. ANY WORK UNDERTAKEN WITHIN 50 FEET OF THE MONORAIL BEAM MUST BE DONE WITH AN OBSERVER
MATERIAL AND EQUIPMENT ARE NOT TO BE STORED WITHIN 50' OF THE EXTERIOR MONORAIL BEAM. THE CONTRACTOR SHALL IDENTIFY THE 50' OFFSET IN THE 17.
PLANNING AND ENGINEERING.
OUTSIDE OF THE ROADWAY CLEARZONE WHEN NOT ACTIVE AND NOT WITHIN TREE AREAS. THE LAYDOWN AREA WILL NEED TO BE PERMITTED WITH CFTOD
16. THE CONTRACTOR SHALL COORDINATE WITH CFTOD CONSTRUCTION FOR LAYDOWN AREAS ON-SITE. ALL MATERIALS AND EQUIPMENT NEED TO BE LOCATED
15. ALL REMOVED ITEMS SHALL BE DISPOSED OF BY THE CONTRACTOR OFF OF CFTOD PROPERTY.
14. THE EXISTING SIGN TRUSS FOUNDATIONS TO BE REMOVED SHALL BE REMOVED TO 4' BELOW THE EXISTING GRADE.
13. COORDINATE WITH CFTOD COMPLIANCE PRIOR TO INSTALLATION OF EROSION CONTROL DEVICES.
OF CONSTRUCTION.
12. THE CONTRACTOR SHALL NOTIFY CFTOD COMPLIANCE PERSONNEL OF THE PROJECT PRE-CONSTRUCTION MEETING PRIOR TO THE COMMENCEMENT
EXISTING DRAINAGE STRUCTURES WITHIN CONSTRUCTION LIMITS SHALL REMAIN UNLESS OTHERWISE NOTED.11.
2025 MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES WITH REVISION 1 AND THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD PLANS 2026-2027.
THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL NECESSARY TRAFFIC CONTROL AND SAFETY DEVICES IN ACCORDANCE WITH THE 10.
THE COORDINATE SYSTEM AND TOPOGRAPHIC INFORMATION IS BASED ON A LOCAL GRID ESTABLISHED BY THE WALT DISNEY COMPANY.9.
ELEVATIONS SHOWN ON THE PLANS ARE BASED ON THE WALT DISNEY WORLD VERTICAL DATUM. 8.
LAKE BUENA VISTA, FL 32830
P.O. BOX 10170
& LOW VOLTAGE ELECTRIC
PROPERTY MANAGEMENT - IRRIGATION, LANSCAPE
TROY INGLE (407) 943-1131CENTRAL FLORIDA TOURISM OVERSIGHT DISTRICT (CFTOD)E.
CELEBRATION, FL 34736
1120 CELEBRATION C203A
SCOTT BUCHANAN (407) 566-5048DISNEY FIBER OPTICD.
LAKE BUENA VISTA, FL 32830
3100 BONNET CREEK ROAD
DAVE CAWLEY (407) 828-6648SMART CITY TELECOMC.
LAKE BUENA VISTA, FL 32830
1920 EAST BUENA VISTA DR, SUITE A
PLANNING AND ENGINEERING
KATHERINE LUETZOW (407) 828-2250CENTRAL FLORIDA TOURISM OVERSIGHT DISTRICT (CFTOD)B.
NATURAL GAS/CHILLED WATER LINES: BRAD BURCHETT (407) 401-2981
ELECTRICITY: ANTHONY KASPER (407) 824-7448
WATER/SEWER: MATT DOAN (407) 824-3684
GENERAL: ANTHONY KASPER (407) 824-7448LAKE BUENA VISTA, FL 32830
UTILITY EMERGENCY (24/7): (407) 824-41855300 CENTER DRIVE
BEFORE DIG: 811: (800)-432-4770REEDY CREEK ENERGY SERVICES (RCES) A.
7. UTILITY CONTACTS ARE AS FOLLOWS:
AFTER 4:00 PM AND ON WEEKENDS, EMERGENCY LOCATES WILL STILL BE PROCESSED THROUGH THE RCES CONTROL ROOM AT 407-824-4185.-
LOCATED AT EPCOT CENTER.
MAY BE MADE VIA EMAIL TO WDW.RCES.UTILITY.LOCATES@DISNEY.COM, VIA FAX TO 407-560-6540, OR IN PERSON AT THE EPCOT CENTRAL ENERGY PLANT THE MAP ALONG WITH THE SUNSHINE TICKET NUMBER MUST BE SUBMITTED BY THE CONTRACTOR TO REEDY CREEK ENERGY SERVICES. THE SUBMITTAL -
ON THE MAP.
THE CONTRACTOR SHALL PREPARE A MAP SHOWING THE AREA IN WHICH UTILITIES ARE TO BE LOCATED AND WRITE THE SUNSHINE TICKET NUMBER - AFTER COMPLETING THE SUBMISSION PROCESS, THE CONTRACTOR WILL BE GIVEN A TICKET NUMBER THAT MUST BE RETAINED.- THE CONTRACTOR SHALL CONTACT SUNSHINE 811 BY CALLING 811 (800-432-4770) OR VISITING HTTP://WWW.SUNSHINE811.COM/ TO SUBMIT A TICKET.-
6. THE CONTRACTOR SHALL UTILIZE THE FOLLOWING STEPS TO SECURE UTILITY LOCATES AT LEAST 72 HOURS PRIOR TO CONSTRUCTION:
DAYS PRIOR TO ANY EXCAVATION.
OF UNDERGROUND UTILITIES AND ANY UTILITY ADJUSTMENT REQUIRED. UTILITY COMPANIES SHALL BE NOTIFIED A MINIMUM OF THREE WORKING DETERMINED BY THE CONTRACTOR DURING CONSTRUCTION. CONTRACTOR IS TO COORDINATE FULLY WITH UTILITY COMPANIES ON EXACT LOCATION OTHER PERMITS AS APPLICABLE. THE LOCATION OF UTILITIES SHOWN IN THE PLANS ARE APPROXIMATE ONLY, THE EXACT LOCATION SHALL BE CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION ACTIVITY FOR DIG PERMIT, ELECTRICAL PERMITS OR 5.
ALL DISTURBED AREAS WITHIN THE LIMIT OF CONSTRUCTION SHALL BE GRADED TO THE ORIGINAL GROUND AND SODDED. ALL SOD SHALL BE BAHIA. 4.
ALL SURVEY AND PUBLIC LAND CORNERS WITHIN THE LIMITS OF CONSTRUCTION SHALL BE PROTECTED AT ALL TIMES.3.
FOR STANDARD DETAILS NOT SHOWN IN PLANS, SEE FDOT STANDARD PLANS DATED 2026-2027.2.
ALL MATERIALS, CONSTRUCTION METHODS AND TESTING SHALL BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.1.
G E
N E
R A
L N
O T
E S
S-3
CERTIFICATION OF AUTHORIZATION 2648
ORLANDO, FLORIDA 32814
941 LAKE BALDWIN LANE
DRMP, INC.
L.S. LICENSE NUMBER 7001
FRANK LOPEZ, P.S.M.
PROJECT. THE PROFESSIONAL SURVEYOR AND MAPPER OF RECORD IS:
THE PRODUCTION OF DESIGN PLANS AND FOR CONSTRUCTION ON SUBJECT
PROFESSIONAL SURVEYOR AND MAPPER ANDUTILIZED AS SUPPORTING DATA IN
6. ALL SURVEY INFORMATION WAS OBTAINED FROM A LICENSED FLORIDA
OF EPCOT CENTER DRIVE.
OF CONSTRUCTION �5. ALL STATION AND OFFSETS SHOWN ARE BASED UPON THE
GENERAL NOTES cont.:
Feet
100200
SECTION 24 TOWNSHIP 24 SOUTH RANGE 27 EAST
POT = POINT ON TANGENT
RT = RIGHT TANGENT
L&T = TACK NAIL IN LEAD PLUG
LT = LEFT TANGENT
STA. = STATION
O/S = OFFSET
WDW = WORLD DISNEY WORLD
IRC = IRON ROD AND CAP
I.D. = IDENTIFICATION
ELEV. = ELEVATION
F.A.C. = FLORIDA ADMINISTRATIVE CODE
= HORIZONTAL AND VERTICAL CONTROL
£ = BASELINE OF SURVEY
LEGEND & ABBREVIATIONS
N.T.S. = NOT TO SCALE
FND. = FOUND
P C S
T A .1
.7
P T S
T A .2
.2
P I S
T A .1
.7
Curve C1
P.I.STA.18+47.71
T = 264.93'
L = 529.51'
R = 6,025.00'
P.C.STA.15+82.78
P.T.STA.21+12.29
STA.14+00.00
PCOT CENTER DRE
BEGIN £ SURVEY
E = 18103.5994 N = 48860.9362
STA. 14+13.26, 13.53' LT.
ELEV. = 116.675'
E = 18112.3910 N = 48877.7060
FND TACK IN LEAD PLUG
TBM-1189700
STA. 18+60.30, 57.46' RT.
ELEV. = 107.993'
E = 18561.4948 N = 48945.5459
SET 5/8" IRC "DRMP LB2648"
TBM-TRES1
STA. 23+23.10, 91.41' RT.
ELEV. = 98.004'
E = 19007.9556 N = 49081.7851
SET 5/8" IRC "DRMP LB2648"
TBM-TFLY1
STA. 25+32.86, 79.25' LT.
ELEV. = 100.635'
E = 19139.3580 N = 49318.1220
FND 5/8" IRC "T.S.S. TRAVERSE P.T."
TBM-1439170
EPCOT CENTER DRIVE
� OF CONSTRUCTION
POT STA.27+99.18
EPCOT CENTER DR
END £ SURVEY
E = 19416.0619 N = 49343.4178
N = NORTHING
E = EASTING
4. DISTANCES SHOWN HERON ARE IN U.S. SURVEY FEET.
AS PROVIDED BY WDW SURVEYOR OFFICE.
VERTICAL DATUM BASED ON VERTICAL CONTROL POINTS 1189700 AND 1439170
3. ELEVATIONS SHOWN HEREON ARE REFERENCED TO WALT DISNEY WORLD (WDW)
1189700 AND 1439170 AS PROVIDED BY WDW SURVEYOR OFFICE.
WORLD (WDW) HORIZONTAL GRID BASE ON SURVEY CONTROL NETWORK POINTS
2. HORIZONTAL COORDINATES SHOWN HEREON ARE REFERENCED TO WALT DISNEY
OVERSIGHT DISTRICT WITHOUT DELAY.
PROJECT ADMINISTRATOR SHOULD NOTIFY THE CENTRAL FLORIDA TOURISM
BE PROTECTED. IF A MONUMENT IS IN DANGER OF BEING DESTROYED, THE
1. ANY PROJECT CONTROL MONUMENT WITHIN THE LIMITS OF CONSTRUCTION IS TO
GENERAL NOTES:
N
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\survey\CTLSRD01.dgn2:39:55 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
/1
/2
E C
D T
R U
S S
R E
P L A
C E
M E
N T
C E
R T
O
F A
U T
H
P H
-9
-5
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U
IT
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
Project Control [Sheet]
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A
State of Florida Stephen W. Dickison
S-4
P R
O J E
C T
C O
N T
R O
18 19 20
.2
S
T A
P T
E 18607.8903
N 48938.0729
STATION 19+00.73, OFF 80.06' (RT)
SIGN UPRIGHT OT-1 RT
E 18585.2103
N 49001.1175
STATION 19+00.73, OFF 13.06' (RT)
SIGN UPRIGHT OT-1 LT
� CONST. EPCOT CENTER DRIVE
10 40
Feet
N
CURVE C1
N68°12'18"E
CURVE DATA (C1)
PI STA. = 18+47.71 N 48990.0244 E 18532.2890
¬ = 05°02'08" (LT)
D = 00°57'03" T = 264.93 L = 529.51 R = 6,025.00
PC STA. = 15+82.78 N 48913.6319 E 18278.6163
PT STA. = 21+12.29 N 49088.3876 E 18778.2775
EB EPCOT CENTER DRIVE
OFF RAMP TO EPCOT
TO BE REMOVED
EXIST SIGN TRUSS
12" CMP
PIPE
DRAINAGE
EXIST
AFTER SIGN TRUSS INSTALLATION
RESTORED TO ORIGINAL CONDITION
DURING CONSTRUCTION AND
EXIST DITCH TO BE MAINTAINED
LIGHTING
RCES ELECTRICAL
RCES ELECTRICAL
LEGEND
INLET PROTECTION
SILT FENCE
M O
N O
R A
IL TR
A C K
M O
N O
R A
IL TR
A C K
ELEC
ELECELEC
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\PLANSP01.dgn4:02:20 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
/1
/2
E C
D T
R U
S S
R E
P L A
C E
M E
N T
C E
R T
O
F A
U T
H
P H
-9
-5
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U
IT
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
CL_EPCOT - Plan 1 [Sheet]
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A
State of Florida Stephen W. Dickison
S
IG
N S
T R
U C
T U
R E
P L
A N
S-5
24 25 26 2725
N68°12'18"E
N
10 40
Feet
� CONST. EPCOT CENTER DRIVE
WB EPCOT CENTER DRIVE
OFF RAMP TO NB WORLD DRIVE
E 19213.6136 N 49266.9345
STATION 25+82.76, OFF 4.15' (LT)
SIGN UPRIGHT OT-2 LT
E 19185.7672 N 49336.5734
STATION 25+82.76, OFF 79.15' (LT)
SIGN UPRIGHT OT-2 RT
TO BE REMOVED
EXIST SIGN TRUSS
R C
P
R C
P
C M
P
PIPE
DRAINAGE
EXIST
OPTIC CABLE
RCES FIBER
LIGHTING
RCES ELECTRICAL
WATER
RCES NON-POTABLE
AFTER SIGN TRUSS INSTALLATION
RESTORED TO ORIGINAL CONDITION
DURING CONSTRUCTION AND
EXIST DITCH TO BE MAINTAINED
LEGEND
INLET PROTECTION
SILT FENCE
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\PLANSP01.dgn4:02:21 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
/1
/2
E C
D T
R U
S S
R E
P L A
C E
M E
N T
C E
R T
O
F A
U T
H
P H
-9
-5
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U
IT
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
CL_EPCOT - Plan 2 [Sheet]
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A
State of Florida Stephen W. Dickison
S
IG
N S
T R
U C
T U
R E
P L
A
S-6
STA. 19+00.73
1" = 10' Vertical
1" = 10' Horizontal
SCALE
20 0 20 40 60 80 100 120
80 80
90 90
100 100
110 110
120 120
130 130
12' 26'-0" (24'-0" MIN CZ)5'-3" 8'-9"
16'-6"
O F
S
IG
N P
A N
E L
M
IN
T
O B
O T
T O
M
V E
R T
IC
A
L C
L E
A R
N A
C E
2'-8"
16' 16'
28'-6"
67'
10'
38'26'-4"
140 140
150 150
LOOKING UP STATION
BE
107.64
105.64
105.97
103.97
107.19
1'-1"
OT-1
DRIVE
EPCOT CENTER
� CONST.
EPCOT
NEXT RIGHT
Disney Springs
LEFT LANE
To R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\RDXSSP01.dgn2:40:13 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
/1
/2
E C
D T
R U
S S
R E
P L A
C E
M E
N T
C E
R T
O
F A
U T
H
P H
-9
-5
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U
IT
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
CL_EPCOT - 19+00.73 [Sheet]
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A
State of Florida Stephen W. Dickison
S
IG
N S
T R
U C
T U
R E
C R
O S
S S
E C
T
IO
S-7
STA. 25+82.76
1" = 10' Vertical
1" = 10' Horizontal
SCALE
20 0 20 40 60 80 100 120
70 70
80 80
90 90
100 100
110 110
120 120
130 130
140 140
12'12' 13'
12'-9"
5'-4" 7'-8"
O F
S
IG
N P
A N
E L
M
IN
T
O B
O T
T O
M
V E
R T
IC
A
L C
L E
A R
N A
C E
23' 23'
1'
39' 35'
75'
22'-6"
PAVED SHLDR 7'-3"
9'-9"
LOOKING BACK STATION
BE
15'-6"
104.20
102.20
105.15
103.15
104.05
1'-1"
OT-2
DRIVE
EPCOT CENTER
� CONST.
FOC
Magic Kingdom
Magic Kingdom Resorts
Fort Wilderness
Disney's Hollywood Studios
Disney's Animal Kingdom
To
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\signing\RDXSSP01.dgn2:40:13 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
T W
O N
O
/1
/2
E C
D T
R U
S S
R E
P L A
C E
M E
N T
C E
R T
O
F A
U T
H
P H
-9
-5
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U
IT
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
CL_EPCOT - 25+82.76 [Sheet]
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A
State of Florida Stephen W. Dickison
S
IG
N S
T R
U C
T U
R E
C R
O S
S S
E C
T
IO
S-8
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\struct\SignStructSpan01.dgn2:40:16 PM
SHEET
P R
O J E
C T
D R
A W
N
C H
E C
K E
D
D E
S
IG
N E
D
T W
O N
O
C H
E C
K E
D
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SpanSignStructuresDataTable
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
License No. 37382
State of Florida
David Michael Waddell
DATE: 4/15/2026
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
S P
A N
S I G
N D
A T
A T
A B
L E
S-8
SPAN SIGN STRUCTURES DATA TABLE (CONT.)
LEFT DRILLED SHAFT RIGHT DRILLED SHAFT
SIGN#
ft in
DA
ft
DB
in # / size
DC DD
DE
in ft
FA
in ft
FB
in # / size
FC FD
FE
in
SPAN SIGN STRUCTURES DATA TABLE (CONT.)
in
CJ
in
CH
in
CG
in
CF
RIGHT BASE CONNECTION
in
CE
ftin
CD
in
CC
CB
in
CA
in
BJ
in
BH
in
BG
in
BF
LEFT BASE CONNECTION
in
BE
ftin
BD
in#
BB
in
BASIGN# BC
SIGN#
in
LA LB
# in
LC
LEFT UPRIGHT CONNECTION
in
LD
in
LE
SPAN SIGN STRUCTURES DATA TABLE (CONT.)
in
LF
in
LG
in
LH
in
RA RB
RC
in
RD
in
RIGHT UPRIGHT CONNECTION
RE
in
RF
in in
RG RH
in
SIGN#
in
PA
in
PB
ALTERNATE SPLICE
in
PC
in
PD
in
PE
PF
in
GA
in
GB
ft in
GC
ft in
GD
ft in
GE
ft in
GF
GUSSET PLATES
SPAN SIGN STRUCTURES DATA TABLE (CONT.)
ft
GG
in ft
GH
in ft
GJ
in ft
GK
in
GL
in in
SC
SB
Angle (in)
SA
SPLICE
in
K (CAMBER)
O. D. x Wall Thk. (in)
J (RIGHT UPRIGHT)
O. D. x Wall Thk. (in)
H (LEFT UPRIGHT)
MEMBER SIZES
SPAN SIGN STRUCTURES DATA TABLE
Angle (in)
G (WEB)
O. D. x Wall Thk. (in)
F (CHORD)
in
E
D
PNLS
ft
C ft
B ft
ASTATIONSIGN#
DIMENSIONS
Table Date 01-01-11
Table Date 01-01-11
Table Date 07-01-14
Table Date 01-01-11
Table Date 01-01-11
Design Water Table is 0 ft. below surface
= 45 pcfSoil Weight
= 29 deg.Soil Friction Angle
= 38.5 ft.Soil Layer Thickness
= SandSoil Type
OT-2
Design Water Table is 0 ft. below surface
= 50 pcfSoil Weight
= 30 deg.Soil Friction Angle
= 43.5 ft.Soil Layer Thickness
= SandSoil Type
OT-1
Assumptions and Values used in design:2.
sealed by GEC Consultants, Inc.
Design based on Borings taken1.
FOUNDATION NOTES:
DF
in
FF
in
'DC' and 'FC' shall include quantity and size of reinforcing steel.5.
approximately 20 to 25% of the truss length from each end.
using two vertical lift points, each located near a panel point
To facilitate erection, the Contractor should consider
Erection is the Contractor's responsibility.4.
Upright wall thickness given is a minimum dimension.3.
Design Wind Speed = 150 mph2.
Work these Data Tables with Index 700-041.1.
NOTES:
OT-1 19+00.73 67.0000 24.1330 25.8030 7 60 5.56 x 0.375 4 x 4 x 1/2 24.00 x 0.562 24.00 x 0.562 1/2 5 x 5 x 1/2 6 7/8
OT-1 1-3/8 2 5/16 3/8 1 9 1/2 7/8 1 9 8 1 5-1/2 6-1/2 2 10 1 3/4 8-1/4 1 2 3/16
OT-1 7/8 6 1/2 1/2 3/16 3/16 3/16 3/16 7/8 6 1/2 1/2 3/16 3/16 3/16 3/16
OT-1 2 10 2 5/8 2 3-1/4 5/16 5/16 5/16 1/4 2 10 2 5/8 2 3-1/4 5/16 5/16 5/16 1/4
OT-1 19 0 5 0 19 / 11 11 8 40 18 0 5 0 19 / 11 11 8 40
OT-2 25+82.76 75.0000 23.4830 24.4330 8 60 5.56 x 0.375 4 x 4 x 1/2 24.00 x 0.562 24.00 x 0.562 3/4 5 x 5 x 1/2 6 7/8
OT-2 1-3/8 2 5/16 3/8 1 9 1/2 7/8 1 8-3/4 8 1 5-1/4 6-1/2 2 9-1/2 1 3/4 8-1/4 1 1-3/4 3/16
OT-2 7/8 6 1/2 1/2 3/16 3/16 3/16 3/16 7/8 6 1/2 1/2 3/16 3/16 3/16 3/16
OT-2 2 10 2 5/8 2 3-1/4 5/16 5/16 5/16 1/4 2 10 2 5/8 2 3-1/4 5/16 5/16 5/16 1/4
OT-2 17 0 5 0 19 / 11 11 8 40 20 0 5 0 19 / 11 11 8 40
OT-1
RT
B-2
OT-1
LT
EPCOT C
ENTER D
R
FULL
SPAN S
IGN S
TURCTURE
(EASTBOUND)
202020
B-1
ELEC
ELEC
ELEC
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\geotech\SPTBSP01.dgn2:40:18 PM
SHEET
P R
O J E
C T
D R
A W
N
A E
B
A P
P R
O V
E D
C
G B
D A
T E
T W
O N
O
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
O R
L A
N D
O F
L
L
A K
E B
A L
D W
IN
L
A N
E
C O
N S
U L
T A
N T
S
IN
C
G E
O T
E C
H N
IC
A
L A
N D
E N
V
IR
O N
M E
N T
A
SPT BORING RESULTS FOR SIGNS
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A .C
S-10
License No. 71571
Professional Engineer
State of Florida
Craig G. Ballock
S
P T
B
O R
I N
G R
E S
U L
T S
F O
R S
I G
N S
S T
A N
D A
R D
P E
N E
T R
A T
I O
N T
E
W/H/18" WEIGHT OF HAMMER FOR 18 INCHES OF PENETRATION
HA HAND AUGERED FOR UTILITY CLEARANCE
GENERAL NOTES
SPLIT SPOON SAMPLER:
INSIDE DIAMETER: 1.375 IN.
OUTSIDE DIAMETER: 2.0 IN.
AVERAGE HAMMER DROP: 30 IN.
HAMMER WEIGHT: 140 LBS.
ENVIRONMENTAL CLASSIFICATION:
SUBSTRUCTURE:
SUPERSTRUCTURE: SLIGHTLY AGGRESSIVE
TOWNSHIP: 24 SOUTH
RANGE: 27 EAST
LEGEND
BT BORING TERMINATED AT DEPTH INDICATED
N STANDARD PENETRATION RESISTANCE, BLOWS PER FOOT
-200=
MC=
LL=
PERCENT PASSING NO. 200 U.S. STANDARD SIEVE
PERCENT NATURAL MOISTURE CONTENT
LIQUID LIMIT
SAND
SAND AND SILT
SAND AND CLAY
PI= PLASTICITY INDEX
GROUND SURFACE ELEVATION (FT. NAVD88)GSE
ELEVATION (FT. NAVD88)
ESTIMATED SEASONAL HIGH GROUNDWATER
+97.3
SECTION: 24
STEEL: MODERATELY AGGRESSIVE (pH=6.2)
CONCRETE: SLIGHTLY AGGRESSIVE (pH=6.2)
OVER 40
24-40
8-24
3-8
0-3
GRANULAR SOILS: SANDS
VERY DENSE
DENSE
MEDIUM DENSE
LOOSE
VERY LOOSE
HARD
VERY STIFF
STIFF
FIRM
SOFT
VERY SOFT
DENSITY
RELATIVE
CONSISTENCY
OVER 24
12-24
6-12
3-6
1-3
0-1
(BLOWS/FT)
N VALUE
(BLOWS/FT)
N VALUE
AUTOMATIC HAMMER
SILTS, CLAYS, MUCK
NON-GRANULAR SOILS:
BE PREPARED TO HANDLE ARTESIAN HEAD LEVELS UP TO +88 FEET NAVD88.
SURFACE OF THE FLORIDAN AQUIFER IN THE PROJECT VICINITY IS APPROXIMATELY +88 FEET NAVD88.
ACCORDING TO THE FDEP SEPTEMBER 2021 POTENTIOMETRIC CONTOURS MAP, THE POTENTIOMETRIC
DENSE LAYERS.
THICKNESS ADEQUATELY TO PREVENT CASING DAMAGE/DEFORMATION DURING INSTALLATION THROUGH
INSTALLATION. WHEN TEMPORARY CASING IS USED, REINFORCE THE CASING TIP SHALL AND THE CASING
AND/OR PROCEDURES AS NECESSARY TO FACILTATE SHAFT EXCAVATION AND/OR TEMPORARY CASING
ENCOUNTER THIS TYPE OF MATERIAL AT ALL SHAFT LOCATIONS AND SHALL USE SPECIALIZED EQUIPMENT
MAY MAKE SHAFT EXCAVATION AND/OR TEMPORARY CASING INSTALLATION DIFFICULT. EXPECT TO
LAYERS OF DENSE TO VERY DENSE SAND MAY BE ENCOUNTERED AT THIS SITE. SUCH MATERIALS
CONTROL. THE BORING LOCATIONS WERE SURVEYED BY DRMP FOR VERTICAL AND HORIZONTAL
UNLESS OTHERWISE NOTED.
PENETRATION RESISTANCES ARE SHOWN ON THE BORINGS AT THE TEST DEPTHS IN BLOWS PER FOOT
STANDARD PENETRATION TEST BORINGS WERE PERFORMED IN ACCORDANCE WITH ASTM D-1586. STANDARD
TESTING SHOWN.
SOIL CLASSIFICATIONS SHOWN ON THE BORINGS ARE BASED ON VISUAL EXAMINATION AND THE LABORATORY
BORING LOCATIONS. ACTUAL CONDITIONS BETWEEN THE BORINGS MAY VARY FROM THOSE SHOWN. UNIFIED
SUBSURFACE CONDITIONS SHOWN ON THE BORINGS REPRESENT THE CONDITIONS ENCOUNTERED AT THE
N
+50
+55
+60
+65
+70
+75
+80
+85
+90
+95
+100
+105
+110
N
E L
E V
A T
IO
N
F
T
N A
V D
HA
HA
HA
W/H/18"
GROUTED
BT AT 55'
+97.3
DATE DRILLED: 3-6-26
DRILLER: L. LEGG
RIG TYPE: TRACK BR 2500
HAMMER TYPE: AUTOMATIC
GSE: +105.3
LONG: W81.56406°
LAT: N28.37860°
STA. 19+01, 13' RIGHT
B-1
-200=11
PI=10
LL=32
MC=42
-200=22
OC=3.8
MC=28
-200=17
GNE @ 11.2'
OC= PERCENT ORGANIC CONTENT
N
HA
HA
HA
W/H/18"
GROUTED
BT AT 50'
+97.1
DATE DRILLED: 3-6-26
DRILLER: L. LEGG
RIG TYPE: TRACK BR 2500
HAMMER TYPE: AUTOMATIC
GSE: +105.1
LONG: W81.56399°
LAT: N28.37845°
STA. 19+04, 72' RIGHT
B-2
+50
+55
+60
+65
+70
+75
+80
+85
+90
+95
+100
+105
+110
E L
E V
A T
IO
N (F
T . N
A V
D
-200=6
GNE @ 12.4'
BROWN FINE SAND WITH SILT (SP-SM)
LIGHT BROWN SILTY FINE SAND (SM)
TRACE ORGANIC MATERIAL
BROWN FINE SAND WITH SILT (SP-SM)
BROWN SILTY FINE SAND (SM)
LIGHT BROWN TO BROWN CLAYEY FINE SAND (SC)
GROUNDWATER NOT ENCOUNTEREDGNE
-200=11
-200=9
-200=20
BROWN FINE SAND WITH SILT (SP-SM)
BROWN SILTY FINE SAND (SM)
LIGHT BROWN TO BROWN FINE SAND WITH SILT (SP-SM)
BROWN SILTY FINE SAND (SM)
GRAY SANDY FAT CLAY (CH)
BROWN FINE SAND WITH SILT (SP-SM)
Feet
0 10
B-1
B-2
OT-2
RT
OT-2
LT
EP
COT
CENTE
R
DR
FULL
S
PAN
SIG
N
STRUCTURE
(W
ES
TBOUND)
B-3
B-3
R E
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\geotech\SPTBSP01.dgn2:40:19 PM
SHEET
P R
O J E
C T
D R
A W
N
A E
B
A P
P R
O V
E D
C
G B
D A
T E
T W
O N
O
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
O R
L A
N D
O F
L
L
A K
E B
A L
D W
IN
L
A N
E
C O
N S
U L
T A
N T
S
IN
C
G E
O T
E C
H N
IC
A
L A
N D
E N
V
IR
O N
M E
N T
SPT BORING RESULTS FOR SIGNS - 2
H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A .C
S-11
License No. 71571
Professional Engineer
State of Florida
Craig G. Ballock
S
P T
B
O R
I N
G R
E S
U L
T S
F O
R S
I G
N S
S T
A N
D A
R D
P E
N E
T R
A T
I O
N T
E
W/H/18" WEIGHT OF HAMMER FOR 18 INCHES OF PENETRATION
HA HAND AUGERED FOR UTILITY CLEARANCE
ENVIRONMENTAL CLASSIFICATION:
SUBSTRUCTURE:
SUPERSTRUCTURE: SLIGHTLY AGGRESSIVE
LEGEND
BT BORING TERMINATED AT DEPTH INDICATED
N STANDARD PENETRATION RESISTANCE, BLOWS PER FOOT
-200=
MC=
LL=
PERCENT PASSING NO. 200 U.S. STANDARD SIEVE
PERCENT NATURAL MOISTURE CONTENT
LIQUID LIMIT
SAND
SAND AND SILT
SAND AND CLAY
PI= PLASTICITY INDEX
GROUND SURFACE ELEVATION (FT. NAVD88)GSE
ELEVATION (FT. NAVD88)
ESTIMATED SEASONAL HIGH GROUNDWATER
+93.3
STEEL: SLIGHTLY AGGRESSIVE
CONCRETE: SLIGHTLY AGGRESSIVE
N
OC= PERCENT ORGANIC CONTENT
+35
+40
+45
+50
+55
+60
+65
+70
+75
+80
+85
+90
+95
+100
+105
N
E L
E V
A T
IO
N
F
T
N A
V D
HA
HA
HA
W/H/18"
GROUTED
BT AT 60'
+93.3
DATE DRILLED: 3-5-26
DRILLER: L. LEGG
RIG TYPE: TRACK BR 2500
HAMMER TYPE: AUTOMATIC
GSE: +97.3
LONG: W81.56211°
LAT: N28.37933°
STA. 25+83, 3' LEFT
B-3
-200=4
PI=32
LL=45
MC=37
-200=56
N
HA
HA
HA
W/H/18"
W/H/18"
+97.7
DATE DRILLED: 3-5-26
DRILLER: L. LEGG
RIG TYPE: TRACK BR 2500
HAMMER TYPE: AUTOMATIC
GSE: +102.7
LONG: W81.56219°
LAT: N28.37956°
STA. 25+95, 93' LEFT
B-4
+95.9
+35
+40
+45
+50
+55
+60
+65
+70
+75
+80
+85
+90
+95
+100
+105
E L
E V
A T
IO
N (F
T . N
A V
D
GROUNDWATER NOT ENCOUNTEREDGNE
GROUTED
BT AT 55'
GNE @ 8'
-200=5
-200=21
BROWN FINE SAND WITH SILT (SP-SM)
BROWN FINE SAND (SP)
BROWN FINE SAND WITH SILT (SP-SM)
LIGHT BROWN SILTY FINE SAND (SM)
BROWN FINE SAND WITH SILT (SP-SM)
BROWN FINE SAND (SP)
BROWN FINE SAND WITH SILT (SP-SM)
SILTY FINE SAND (SM)
LIGHT BROWN TO BROWN
GRAY CLAYEY FINE SAND (SC)
GRAY SANDY LEAN CLAY (CL)
GRAY SILTY FINE SAND (SM)
BROWN FINE SAND WITH SILT (SP-SM)
LIGHT BROWN FINE SAND (SP)
BROWN FINE SAND WITH SILT (SP-SM)
BROWN SILTY FINE SAND (SM)
LIGHT BROWN TO BROWN FINE SAND WITH SILT (SP-SM)
LIGHT BROWN SILTY FINE SAND (SM)
BROWN SANDY LEAN CLAY (CL)
LIGHT BROWN SILTY FINE SAND (SM)
BROWN TO GRAY CLAYEY FINE SAND (SC)
-200=3
-200=8
PI=28
LL=39
MC=36
-200=62
PI=20
LL=37
MC=47
-200=45
GENERAL NOTES
SPLIT SPOON SAMPLER:
INSIDE DIAMETER: 1.375 IN.
OUTSIDE DIAMETER: 2.0 IN.
AVERAGE HAMMER DROP: 30 IN.
HAMMER WEIGHT: 140 LBS.
TOWNSHIP: 24 SOUTH
RANGE: 27 EAST
SECTION: 24
OVER 40
24-40
8-24
3-8
0-3
GRANULAR SOILS: SANDS
VERY DENSE
DENSE
MEDIUM DENSE
LOOSE
VERY LOOSE
HARD
VERY STIFF
STIFF
FIRM
SOFT
VERY SOFT
DENSITY
RELATIVE
CONSISTENCY
OVER 24
12-24
6-12
3-6
1-3
0-1
(BLOWS/FT)
N VALUE
(BLOWS/FT)
N VALUE
AUTOMATIC HAMMER
SILTS, CLAYS, MUCK
NON-GRANULAR SOILS:
BE PREPARED TO HANDLE ARTESIAN HEAD LEVELS UP TO +88 FEET NAVD88.
SURFACE OF THE FLORIDAN AQUIFER IN THE PROJECT VICINITY IS APPROXIMATELY +88 FEET NAVD88.
ACCORDING TO THE FDEP SEPTEMBER 2021 POTENTIOMETRIC CONTOURS MAP, THE POTENTIOMETRIC
DENSE LAYERS.
THICKNESS ADEQUATELY TO PREVENT CASING DAMAGE/DEFORMATION DURING INSTALLATION THROUGH
INSTALLATION. WHEN TEMPORARY CASING IS USED, REINFORCE THE CASING TIP SHALL AND THE CASING
AND/OR PROCEDURES AS NECESSARY TO FACILTATE SHAFT EXCAVATION AND/OR TEMPORARY CASING
ENCOUNTER THIS TYPE OF MATERIAL AT ALL SHAFT LOCATIONS AND SHALL USE SPECIALIZED EQUIPMENT
MAY MAKE SHAFT EXCAVATION AND/OR TEMPORARY CASING INSTALLATION DIFFICULT. EXPECT TO
LAYERS OF DENSE TO VERY DENSE SAND MAY BE ENCOUNTERED AT THIS SITE. SUCH MATERIALS
CONTROL. THE BORING LOCATIONS WERE SURVEYED BY DRMP FOR VERTICAL AND HORIZONTAL
UNLESS OTHERWISE NOTED.
PENETRATION RESISTANCES ARE SHOWN ON THE BORINGS AT THE TEST DEPTHS IN BLOWS PER FOOT
STANDARD PENETRATION TEST BORINGS WERE PERFORMED IN ACCORDANCE WITH ASTM D-1586. STANDARD
TESTING SHOWN.
SOIL CLASSIFICATIONS SHOWN ON THE BORINGS ARE BASED ON VISUAL EXAMINATION AND THE LABORATORY
BORING LOCATIONS. ACTUAL CONDITIONS BETWEEN THE BORINGS MAY VARY FROM THOSE SHOWN. UNIFIED
SUBSURFACE CONDITIONS SHOWN ON THE BORINGS REPRESENT THE CONDITIONS ENCOUNTERED AT THE
Feet
0 10
B-4
B-3
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\roadway\B0GenNotes01_MOT.dgn2:40:21 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SHEET-1 [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
State of Florida
Stephen W. Dickison
TO ROAD CLOSURE
TWO WEEKS PRIOR
CLOSURE
DURING ROAD
(PCMS-2)
CHANGEABLE MESSAGE SIGN MESSAGE
TO ROAD CLOSURE
TWO WEEKS PRIOR
CLOSURE
DURING ROAD
(PCMS-1)
CHANGEABLE MESSAGE SIGN MESSAGE
SIGNS
DETOUR
FOLLOW
XXPM-XXAM
MM/DD
MM/DD TO
CLOSURE
ROAD
FUTURE
DRIVE
CENTER
WB EPCOT
BY A BARRIER OR CRASH CUSHION WHEN NOT IN USE.
MOVED OUTSIDE THE TRAVEL WAY AND CLEAR ZONE OR BE SHIELDED
DEVICE PLACED AT EACH CORNER WHEN IN USE AND SHALL BE
MOUNTED DEVICES SHALL BE DELINEATED WITH A CHANNELIZING
PORTABLE CHANGEABLE MESSAGE SIGNS AND ANY OTHER TRAILER
:NOTE
SIGNS
DETOUR
FOLLOW
XXPM-XXAM
MM/DD
MM/DD TO
CLOSURE
ROAD
FUTURE
DRIVE
CENTER
EB EPCOT
TO ROAD CLOSURE
TWO WEEKS PRIOR
CLOSURE
DURING ROAD
(PCMS-3)
CHANGEABLE MESSAGE SIGN MESSAGE
SIGNS
DETOUR
FOLLOW
XXPM-XXAM
MM/DD
MM/DD TO
CLOSURE
RAMP
FUTURE
DRIVE
CENTER
EB EPCOT
M O
T N
O T
E S
S-12
6. INSTALL NEW SIGNS BEFORE EXISTING SIGNS ARE REMOVED.
INSTALL ALL GUIDESIGNS ON THE TRUSS PRIOR TO INSTALLATION OF THE TRUSS AND SIGN OVER TRAVEL LANES.
5. IN ORDER TO FACILITATE CONSTRUCTION AND REDUCE ROAD CLOSURE/DETOUR DURATIONS, THE CONTRACTOR SHALL
CENTER DRIVE CAN NOT BE CLOSED WITHIN THE SAME CLOSURE PERIOD.
PERMITTED FROM TWO HOURS AFTER THE LATEST PARK CLOSURE TIME UNTIL 6 AM. EASTBOUND AND WESTBOUND EPCOT
REQUESTS SHALL BE SUBMITTED A MINIMUM OF 2 WEEKS PRIOR TO ANY CLOSURES. ROAD AND RAMP CLOSURES ARE ONLY
4. THE CONTRACTOR SHALL COORDINATE ALL ROAD AND RAMP CLOSURES WITH THE OWNER'S REPRESENTATIVE FOR APPROVAL.
EPCOT CENTER DRIVE.
BE IMPLEMENTED DURING OVERHEAD INSTALLATION AND DEMOLITION OF THE EXISTING OVERHEAD SIGN STRUCTURES ON
3. THE CONTRACTOR SHALL USE STANDARD FDOT INDEXES FOR SHOULDER WORK. ROAD CLOSURES AND DETOUR PLAN WILL ONLY
AND REMOVAL OF ALL DEVICES REQUIRED TO FACILITATE THE MOT.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN PROVISION, INSTALLATION, MAINTENANCE
HIGHWAY ADMINISTRATION'S MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
OF THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD PLANS AND SPECIFICATIONS AND FEDERAL
1. ALL MAINTENANCE OF TRAFFIC (MOT) SHALL BE IN ACCORDANCE WITH THE LATEST APPLICABLE SECTIONS
MOT NOTES:
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\roadway\B0Detour01.dgn2:32:16 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SHEET [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
State of Florida
Stephen W. Dickison
EPCOT
CENTER DR
EB EPCOT
DETOUR
CLOSED
EXIT
EPCOT
CENTER D
R
EB E
PCOT
DET
OUR
EPCOT
CENTER D
R
EB E
PCOT
DET
OUR
EPCOT
CENTER D
R
EB E
PCOT
DET
OUR
E P C O T
C E N T E R D
R
E B E
P C
T O
U R
E P C
O T
C E
N T E R D
R
E B E
P C
T O
U R
E P C
O T
C E
N T E R D
R E B E
P C
T
O U
R
E P C
O T
C E N T E R D
R E B E
P C
T
O U
R
E P C
O T
D E T
O U
R
E P C O T
D E T O
U R
C E N T E R D
R
E B E
P C
T O
U R
EPCOT
DETOUR
E P C
O T
D E
T O
U R
E N
D D
E T
O U
R
END
DETOUR
E P C
O T
C E
N T E R D
R
E B E
P C
T O
U R
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
EPCOT
DETOUR
O T
-1 R
E P
L A
C E
M E
N T
D E
T O
U R
P L
S-13
LEGEND
RAMP CLOSURE
DETOUR ROUTE
SB WORLD DRIVE DETOURS
FROM
EB EPCOT CENTER DRIVE ACCESS
AND
EPCOT RESORT ENTRANCE
EPCOT ENTRANCE PLAZA
RAMP CLOSURE
EB EPCOT CENTER DR.
SB WORLD DR. TO
REPLACEMENT
OT-1 SIGN TRUSS
PCMS #3
TYPE III BARRICADE
RESORT
BROADWALK
RESORT
SWAN
E P C
O T R
E S
O R T S B
L V
D
BUENA VISTA DR.
V I C
T O
Y
W
Y
C H
E L
O N I A
P
K W
Y
B A
C K
S T
A G
E
L
N
B O
N N
E T
C
R E
E K
P
K W
Y
DISNEY VACATION CLUB
RESORT
ORLEANS
PORT
E P
C O
T
C
E N
T E
R
D
R
EPCOT
E P
C O
T
R
E S
O R
T S
B
L V
D
W O
R L
D
D
R
RESORT
DOLPHIN
RESORT
CLUB
BEACH
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\roadway\B0Detour02.dgn2:32:51 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SHEET-1 [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
State of Florida
Stephen W. Dickison
END
DETOUR
E N
D
D E T O
U R
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
END
DETOUR
D E T O
U R
S B W
O R
LD
D
R
D E T
O U
R
N B W
O R L D D
R
E P C
O T
S B W
O R L D D
R D
E T
O U
R
D E T O
U R
N B /S
B
W O R
LD
D
R
E P C
O T
D E
T O
U R
N B /S
B
W O
R L D D
R
E P C
O T
D E T
O U
R N
B /S
B W
O R L D D
R E P C
O T
D E T
O U
R N B /S
B W
O R L D D
R E P C
O T
D E T O
U R
N B /S
B
W O R
LD
D
R
E P C
O T
DET
OUR
NB/S
B
WORLD D
R
DET
OUR
NB/S
B
WORLD D
R
DETOUR
NB/SB
WORLD DR
EPCOT
DETOUR
DETOUR
NB/SB
WORLD DR
CLOSED
EXIT
C L O S E
D
E X
IT
C L O S E
D
E X
IT
D E T
O U
R
N B /S
B
W O
R L D D
R
D E T O
U R
V A C
A T
IO
N C
LU
B
DETOUR
VACATION CLUB
O T
-2 R
E P
L A
C E
M E
N T
D E
T O
U R
P L
A N
S-14
N
LEGEND
RAMP CLOSURE
DETOUR ROUTE
DETOURS
WB EPCOT CENTER DRIVE
FROM
WORLD DRIVE ACCESS
AND
EPCOT RESORT EXIT
TO NB WORLD DRIVE
TO SB WORLD DRIVE
RAMP CLOSURE
NB/SB WORLD DRIVE
EPCOT EXIT TO
RAMP CLOSURE
SB WORLD DRIVE
NB EPCOT CENTER DR. TO
RAMP CLOSURE
TO NB WORLD DRIVE
WB EPCOT CENTER DR.
REPLACEMENT
OT-2 SIGN TRUSS
FOR DETOUR DETAILS
ON "DETOUR PLAN"
SEE INSET GRAPHIC
TYPE III BARRICADE
PCMS #1
PCMS #1
TYPE III BARRICADE
RESORT
BROADWALK
RESORT
SWAN
E P C
O T R
E S
O R T S B
L V
D
BUENA VISTA DR.
V I C
T O
Y
C H
E L
O N I A
P
K W
Y B
A C
K S
T A
G E
L
N
B O
N N
E T
C
R E
E K
P
K W
Y
DISNEY VACATION CLUB
RESORT
ORLEANS
PORT
E P
C O
T
C
E N
T E
R
D
R
EPCOT
E P
C O
T
R
E S
O R
T S
B
L V
D
W O
R L
D
D
R
RESORT
DOLPHIN
RESORT
CLUB
BEACH
V
IS
IO
N
S
N O
B
Y D
A T
E R
E A
S O
N
4/15/2026Steve Dickison J:\PROJECTS\T202502 - CFTOD C006779 GEC Services\TWO No. 1_ECD OH Truss Design\_TWO01_ECD OH TRUSS\roadway\B0Detour04_InsetGraphic.dgn2:32:55 PM
SHEET
P R
O J E
C T
D R
A W
N
A P
P R
O V
E D
D A
T E
C
E C
D T
R U
S S
R E
P L
A C
E M
E N
T
C E
R T
O
F A
U T
H
P H
O R
L A
N D
O
F L
S
O U
T H
O R
A N
G E
A V
E S
U I T
E
T L
P E
N G
IN
E
E R
IN
G
C O
N S
U L
T A
N T
S
IN
C
SHEET [Sheet]
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A
State of Florida
Stephen W. Dickison
WB CLOSURE
EPCOT CENTER DRIVE (ECD)
D
IS
NEY
VACATI
ON
CLUB
W
AY
OVERPASS ROAD
B
V D
E C
D
O F
F
R
A M
P
D E
T O
U R
V A C
A T
IO
N C
L U
B D
E T
O U
R
N B /S
B
W O
R L D D
R
E P C
O T
DETOUR
VACATION CLUB
DETOUR
NB/SB
WORLD DR
DETOUR
NB/SB WORLD DR
DETOUR
NB/SB
WORLD DR
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
LEGEND
Work Zone Sign
Message Sign Portable Changeable (Variable)
Type III Barricade
Channelizing Device (See Index 102-600)
END
DET
OUR
EPCOT
DETOUR
NB/SB
WORLD DR
DETOUR
NB/SB WORLD DR EPCOT
D E
T O
U R
V A C
A T
IO
N C
L U
B
NB/S
BWORLD D
REPCOT
VACATIO
N C
LUB
DET
OUR
D E T O
U
RN
B /S
B
W O R
LD
D
R
E P C O T
V A C A T
IO
N C
LU
B
C L O S E
D E
X
IT
N B /S
B W
O R
LD
D
R E P C
O T
D E T O
U R
O T
-2 R
E P
L A
C E
M E
N T
D E
T O
U R
P L
A N
S-15
N
THE ECD OFF RAMP ONTO BVD.
THE TWO (2) RIGHT LANES WILL BE FORCED TO TAKE
OUTERMOST LANES.
BE CLOSED AND TRAFFIC SHIFTED TO THE TWO
LANES (LANES CLOSEST TO GRASS MEDIAN) WILL
PER FDOT INDEX 102-613. THE TWO INNERMOST
A DOUBLE DOUBLE LANE SHIFT SHOULD BE USED
LEGEND
RAMP CLOSURE
DETOUR ROUTE
PCMS #1
B A
C K
S T
A G
E
L
N
DI
SNEY
VACATI
ON
CLUB
C H
E L O
N I A
P
K
| KEYSSP01 |
| SIGNSP01 |
| GNNTSP01 |
| CTLSRD01 |
| PLANSP01 |
| PLANSP01 |
| RDXSSP01 |
| RDXSSP01 |
| SignStructSpan01 |
| SPTBSP01 |
| SPTBSP01 |
| B0GenNotes01_MOT |
File details come from the government source that posted it. Updated .