This document is a 100% Construction Documents package for Plumbing Services Repair at the USDA APHIS PPQ Phoenix Rearing Facility located at 3645 East Chipman Road, Phoenix, Arizona 85040, under contract number APHIS-MN-126395.
The project scope focuses on remediation of existing plumbing concerns through removal and replacement of piping in multiple areas, requiring concrete slab cutting and patching to match adjacent surfaces. All existing restroom fixtures will be replaced in kind in the same locations following plumbing work. Additional work includes partial wall demolition and reconstruction for vent replacement, reconfiguration of south restrooms to create a single occupant ADA-accessible shower room with new walls, wall-mounted sink, and water closet, and installation of new finishes including countertops, LED lighting upgrades, wall and ceiling paint, tile flooring, and tile base. The project is designed to accommodate 545 total building occupants based on occupancy calculations (Business 1 occ per 150 SF, Storage 1 occ per 300 SF, Warehouse 1 occ per 500 SF, Workshop 1 occ per 50 SF, Utility 1 occ per 300 SF). The existing building is a 4-inch concrete slab on grade with 8-inch CMU mass walls constructed in 1992. No work undertaken will increase occupancy counts, alter overall square footage, or change existing exit paths. The construction documents include detailed architectural plans, plumbing schedules and details, electrical lighting and power plans, fixture mounting heights, materials schedules, door and hardware specifications, and finishes plans prepared by Cushing Terrell architects and engineers.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFIs-and-Responses.docx | DOCX document | |
| 12639526Q0197-0005.pdf | ||
| More RFIs and Responses.docx | DOCX document | |
| RFIs and Responses.docx | DOCX document | |
| Attendance_07212026 site visit.pdf | ||
| 12639526Q0197-0003.pdf | ||
| C04_12639526Q0197.docx | DOCX document | |
| 12639526Q0197-0002.pdf | ||
| 12639526Q0197-0001.pdf | ||
| C04_Atch 4_Federal Construction Wage Rates_Maricopa.txt | TXT text file | |
| C04_12639526Q0197.docx | DOCX document | |
| C04_Atch 1_Statement of Work.docx | DOCX document | |
| C04_Atch 2_Specifications.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP: Locator
PROJECT ADDRESS
SHEET INDEX
REVISIONS
6/13/2025 10:48:07 AM
COVER SHEET
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
© 2025 | ALL RIGHTS RESERVED
E
AS
T C
H
IP
M
AN
R D
. P H
O
EN
IX
, A
R
IZ
O N
A
3645 EAST CHIPMAN RD. PHOENIX, ARIZONA
85040
USDA APHIS PPQ PHOENIX REARING FACILITY - APHIS-MN-126395
PLUMBING SERVICES REPAIR
100% CONSTRUCTION DOCUMENTS
06/16/2025
3645 EAST CHIPMAN RD. PHOENIX, ARIZONA 85040
| Project# PROJECT# | L:\
06/16/2025
100% CONSTRUCTION
DOCUMENTS
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
G001
OWNER
USDA APHIS
250 MARQUETTE AVE SUITE 410
MINNEAPOLIS, MN 55401
ARCHITECT/ENGINEER
Cushing Terrell 800 W Main St #800 Boise, ID 83702 208.577.5608 Tom Dietrich
ARCHITECTURAL
A000 OVERALL PLAN AND CODE ANALYSIS
A001 RESTROOM DEMO AND PROPOSED FLOORPLANS
A002 INTERIOR ELEVATIONS AND LEGENDS
A003 DETAILS & SCHEDULES
A004 OVERALL FINISH PLAN
GENERAL
G001 COVER SHEET
PLUMBING
P001 PLUMBING SCHEDULES LEGENDS AND DETAILS
PD100 OVERALL PLUMBING DEMOLITION PLAN
PD101 PLUMBING DEMOLITION PLAN - AREA 1
PD102 PLUMBING DEMOLITION PLAN - AREA 2
PD103 PLUMBING DEMOLITION PLAN - AREA 3
PD104 PLUMBING DEMOLITION PLAN - AREA 4
PD105 PHOTO REFERENCES
P100 OVERALL PLUMBING PLAN
P101 PLUMBING PLAN - AREA 1
P102 PLUMBING PLAN - AREA 2
P103 PLUMBING PLAN - AREA 3
P104 PLUMBING PLAN - AREA 4
P201 ENLARGED PLUMBING PLANS
ELECTRICAL
E001 ELECTRICAL LEGENDS
E002 RESTROOM ELECTRICAL PLANS
CONTRACT NUMBER: 12639521D0052
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
DateSignedARIZONA U.S.A
MATCHLINE 2
MATCHLINE 3
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
MATCHLINE 2
MATCHLINE 3
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
MATCHLINE 1
MATCHLINE 3
A001
A001
APPROXIMATE LOCATION
OF ELECTRICAL PANEL LC
MENS
RESTROOM
WOMENS
RESTROOM
CODE REVIEW INFORMATION
APPLICABLE CODES:
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
AMERICAN BARRIERS ACT GUIDELINES (ABA)
EXISTING BUILDING:
THE BUILDING IS LOCATED IN PHOENIX ARIZONA AND WAS FIRST CONSTRUCTED AS A
FACTORY AND LATER REMODELED TO ITS CURRENT STATE IN 1992. IT IS 4" CONCRETE
SLAB ON GRADE - WITH THE EXCEPTION OF THE PIT (3000 PSF). AT THE JOINTS IN THE
SLABS, THERE IS A 3' WIDE AREA OF SLAB THICKENING ON EITHER SIDE OF THE TOOLED
JOINT. THIS THICKER AREA IS 7.5", STARTING 6" AWAY FROM THE JOINTS AND EVENLY
SLOPES TO 4" THICKNESS 1'-6" AWAY FROM JOINTS. AT THE PERIMETER, THE SLAB IS
TURNED DOWN FOR 18" MIN WITH #4 REBAR AT THE TOP AND BOTTOM. THE BEARING OF
EXISTING FOOTINGS WAS 2500PSF, TYPICAL AND 3500 PSF AT THE PIT.
THE EXISTING ROOF IS SUPPORTED BY OPEN WEB STEEL JOISTS AND 1.5" TYPE B-30
METAL ROOF DECK. MASS WALLS ARE 8" CMU, MORTAR TYPE X, WITH #5 VERTICAL
REINFORCEMENT AT CORNERS, INTERSECTIONS, WALLS ENDS, JAMBS, AND JOISTS OR
OTHERWISE AT 48" OC WHERE NONE OF THE PREVIOUSLY LISTED CONDITIONS OCCUR.
PARTITION WALLS IN AREA OF WORK ARE 2x4 WOOD OR 3-5/8" METAL STUDS WITH 5/8" GYPSUM BOARD. EXISTING BLOCKING IN WALLS IS 2x WOOD
PROJECT OVERVIEW:
THE PROJECT SCOPE IS FOCUSED ON REMEDIATION OF THE EXISTING PLUMBING
CONCERNS. THESE INCLUDE REMOVING AND REPLACING PIPING IN SEVERAL AREAS OF
THE BUILDING WHICH WILL BE DONE BY SAW CUTTING THE CONCRETE FLOORING,
COMPLETING THE PLUMBING WORK AND PATCHING BACK THE FLOORING TO MATCH
ADJACENT.
IN ADDITION TO REPLACING PIPING IN RESTROOMS, ALL EXISTING RESTROOM FIXTURES
ARE PLANNED TO BE REPLACED IN KIND IN THE SAME LOCATIONS AFTER THE
COMPLETION OF PLUMBING WORK. ADDITIONAL VENT REPLACEMENT WORK WILL
INCLUDE SOME PARTIAL WALL DEMOLITION AND RECONSTRUCTION TO MATCH PREVIOUS
CONDITION.
IN AN EFFORT TO INCREASE ACCESSIBILITY WITHIN THE BUILDING, THE EXISTING
SHOWERS AND (1) STALL/URINAL IN THE SOUTH RESTROOMS WILL BE REMOVED AND THIS
AREA WILL BE RE-PURPOSED INTO A SINGLE OCCUPANT SHOWER ROOM TO SERVE THE
BUILDING. THE SHOWER WILL HAVE NEW WALLS INSTALLED TO ENCLOSE AN ABA
ACCESSIBLE SHOWER, WALL-MOUNTED SINK, AND NEW water closet. THE FINISHES AND
ACCESSORIES IN THIS ROOM ARE INTENDED TO MATCH THE OTHER MULTI-OCCUPANT
RESTROOMS.
TO ACCOMMODATE THE EXTENT OF WORK, AS DETERMINED BY CONTRACTOR, REQUIRED
TO REPLACE THE PLUMBING FIXTURES AND VENTS, NEW FINISHES WILL BE INSTALLED
AND WILL INCLUDE NEW COUNTERTOPS TO MOUNT SINKS IN, LIGHTING UPGRADES TO
LED FOR INCREASED POWER SAVINGS, WALL AND CEILING PAINT, TILE FLOORING, AND
TILE BASE ALONG THE WALL TO UPDATE THE EXISTING. SEE MATERIALS SCHEDULE AND
INTERIOR ELEVATIONS FOR FULL SCOPE OF WORK.
NO WORK UNDERTAKEN DURING THIS PROJECT WILL INCREASE OR CHANGE OCCUPANCY
COUNTS, IMPACT THE OVERALL SQUARE FOOTAGE OF THE BUILDING OR ALTER THE
EXISTING EXIT PATHS WHICH EXIST. THESE PORTION OF THE CODE ARE INTENDED TO
REMAIN IN WHATEVER CONDITION THEY CURRENTLY EXIST IN AND ARE NOT INCLUDED IN
THE CODE ANALYSIS AS A RESULT.
IBC CODE ANALYSIS:
OCCUPANCY CALCULATIONS
EACH ROOM OF THE BUILDING WAS EVALUATED TO DETERMINE A 'WORST CASE
SCENARIO BUILDING OCCUPANCY COUNT. THIS TOTAL WAS USED TO CALCULATE
THE REQUIRED PLUMBING FIXTURES FOR THE BUILDING
BUSINESS 1 OCC : 150 SF
STORAGE 1 OCC : 300 SF
WAREHOUSE 1 OCC : 500 SF
WORKSHOP 1 OCC : 50 SF
UTILITY 1 OCC : 300 SF
TOTAL: 545 OCCUPANTS (ENTIRE BUILDING)
CHAPTER 29 PLUMBING FIXTURES:
545 OCCUPANTS CONSIDERED (273 MEN AND 273 WOMEN)
REQUIRED FIXTURES BASED ON REQUIREMENTS FOR 'FACTORY' AND
'WAREHOUSE' TO REFLECT THE FUNCTION OF THE BUILDING AS WHOLE,
USING THE MORE RESTRICTIVE WHERE THEY VARY
REQUIRED FIXTURES PROVIDED FIXTURES
SINKS
M 1 LAV PER 100 OCC = 3 2 LAVS AT NORTH, 3 AT SOUTH
W 1 LAV PER 100 OCC = 3 2 LAVS AT NORTH, 3 AT SOUTH
water closets*
M 1 WC PER 100 OCC = 3 2 WC* AT NORTH, 3* AT SOUTH
W 1 WC PER 100 OCC = 3 1 WC AT NORTH, 3 AT SOUTH
*URINALS CAN BE SUBBED FOR NO MORE THAN 50% OF REQUIRED water closets
SHOWERS
ALL NO SHOWERS REQUIRED 2 EXISTING + 1 ABA PROVIDED
ADDITIONAL UNISEX
ABA SHOWER WILL BE GENDER NEUTRAL AND HAVE AN ADDITIONAL water closet AND SINK
WHICH WILL SUPPLEMENT THE REQUIREMENT FOR (1) OF EACH FOR EACH GENDER
DRINKING FOUNTAIN
ALL 1 DF PER 400 OCC = 2
2 EXISTING DRINKING FOUNTAINS EXIST, AS WELL AS WATER DISPENSERS IN
BREAK ROOMS
JANITOR SINK- NO CHANGES TO JAN SINK
ABA ANALYSIS
F202.3 Alterations are defined in the standards (§F106.5) as “a change in a building or facility that affects or could affect the usability of a building or facility or portion thereof.” Many types of projects are covered as “alterations”, including remodeling, renovation, rehabilitation, reconstruction, restoration, resurfacing of circulation paths or vehicular ways, and changes or rearrangement of structural parts, elements, or walls. Normal maintenance, reroofing, painting or wallpapering, or changes to mechanical and electrical systems are not considered alterations unless they affect a facility’s usability. Only those elements or spaces altered are required to comply, but alterations made to areas containing a primary function (a major activity for which a facility is intended) also require an accessible path of travel.
In a restroom project involving alterations to the water closet, grab bars, faucet controls, and mirror, the standards apply to these elements but not to those that remain unaltered. In more extensive projects where additional elements are altered, application of the standards is greater, commensurate with the scope of work."
*CLEARANCES AT FIXTURES ARE NOTED DASHES LINE AND HANDICAP SYMBOL ON
FLOORPLANS ON SHEET A001
**SEE MOUNTING HEIGHT SCHEDULE ON A002 AND CLEARANCE DETAILS ON A003 FOR
ADDITIONAL INFORMATION.
FIRE PROTECTION GENERAL NOTE:
GENERAL CONTRACTOR TO ENGAGE A REGISTERED DESIGN PROFESSIONAL, PER
THE INTERNATIONAL FIRE CODE SECTION 106.1 (IBC SECTION 107), TO PROVIDE
CONSTRUCTION DOCUMENTS/PRELIMINARY WORKING PLANS FOR ALL REQUIRED
MODIFICATIONS TO THE EXISTING FIRE PROTECTION SYSTEMS IF REQUIRED BY THE FIRE
CODE OFFICIAL. GENERAL CONTRACTOR IS TO ENGAGE FIRE SPRINKLER AND FIRE ALARM
CONTRACTORS TO PROVIDE SHOP DRAWINGS/WORKING PLANS PER THE INTERNATIONAL
BUILDING CODE SECTION 106.2 (IBC SECTION 107) AND INSTALLATION PER THE
REFERENCED INSTALLATION STANDARDS (NFPA) OF THE INTERNATIONAL FIRE CODE,
CHAPTER 9. SYSTEMS WITH NO ADDITIONAL SPRINKLER ADDITIONS OR CHANGE OF NFPA
13 FIRE HAZARD OCCUPANCY WILL NOT REQUIRE CALCULATIONS PER NFPA 13.
MENS
RESTROOM
WOMENS
RESTROOM
ALL GENDER
SHOWER
ROOM
REVISIONS
6/13/2025 10:48:09 AM
OVERALL PLAN AND
CODE ANALYSIS
A000 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
E
AS
T
C H
IP
M
AN
R
D . P
H O
EN
IX
, A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
1/16" = 1'-0"A000
1 FIRST FLOOR OVERALL PLAN - FOR REFERENCE ONLY
NORTH REF
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
2 7
8 8
MENS
RESTROOM
WOMENS
RESTROOM
24 22
24 23
CT1
CT1
34A002
A002
MENS
RESTROOM
WOMENS
RESTROOM
29 29
CLCL
1'-8" 2'-8"
CLCL 2'-8" 1'-6"
TY
P
2' -1
CLCL
1'-0" MIN 1'-4"
CLCL1'-0" MIN 1'-4"
HOOK
CURT
CURT
HOOK
A0022
A002
9' -2
/4
8' -9
/2
5'
-0
/2 " C
LR
7'-5 3/8" 6'-2 3/4" 7'-6 1/2" 8'-1 5/8"
CT1CT1
CT1
A0024 5 7 1/4" +/-
(VERIFY WITH INSERT)
5'-3 1/2"
1'
-7
MENS RESTROOM
WOMENS RESTROOM
ALL GENDER SHOWER ROOM
2'-0"
" C
LR
" C
LR
" C
LR
3' -0
5'
-9
/2
C L
1' -8
C L C L
C L
EQ
EQ
C L
1' -8
C L 1'
-8 "C L
C L C L
EQ
EQ
C L 1'
-8
CG1 CG1
CG1
CG1
CG1
CG1
CG1
TYP
2'-1"
37 37
37 37
A.
B.
C.
D.
E.
F.
G.
H.
I.
FIELD VERIFY ALL EXISTING CONDITIONS AND ALERT
ARCHITECT/ENGINEERS OF ANY DISCREPANCIES BETWEEN DRAWINGS
AND SITE CONDITIONS.
EXISTING GYPSUM WALLS WHICH ARE TO REMAIN ARE TO BE CLEANED,
PATCHED, AND REPAIRED AS REQUIRED FOR UNIFORM FINISH IN ENTIRE
ROOM. ALL WALLS ARE TO BE PAINTED TO MATCH THE EXISTING PAINT
COLOR IN ROOM.
CEILING GYPSUM FINISH IN BOTH EXISTING RESTROOMS ARE TO BE
COMPLETELY REMOVED TO ACCOMMODATE PLUMBING WORK.
FOLLOWING PLUMBING WORK, NEW GYPSUM SHOULD BE INSTALLED IN
ROOMS, UTILIZING THE EXISTING CEILING FRAMING, EXCEPT WHERE
FRAMING IS REQUIRED TO BE ADJUSTED FOR NEW SHOWER ROOM
LAYOUT. PAINT GYPSUM CEILINGS TO MATCH EXISTING CEILINGS AND
WALLS.
LIGHTING FIXTURES IN RESTROOMS ARE TO BE REMOVED AND NEW LED
FIXTURES INSTALLED IN THE SAME LOCATIONS. SEE ELECTRICAL
CEILING PLANS ON E001 FOR ADDITIONAL INFORMATION.
PROVIDE LAVATORY GUARDS UNDER SINKS ANYWHERE PIPING IS
EXPOSED TO VIEW IN ROOM, TYPICAL OF ALL SINKS IN AREAS OF WORK.
PROVIDE (2) EXTRA LAV GUARDS TO GOVERNMENT UPON COMPLETION
OF WORK.
PROVIDE BLOCKING IN WALLS AT ANY NEW WALL MOUNTED EQUIPMENT
AND EQUIPMENT THAT IS BEING REPLACED, THIS INCLUDES: COUNTER
BRACKETS, GRAB BARS, HOOKS, water closet ACCESSORIES, ETC
SLAB CUTTING AND REMOVAL OF CONCRETE IS TO BE KEPT AS MINIMAL
AS POSSIBLE TO COMPLETE WORK AS SHOWN IN PLUMBING DRAWINGS.
CONTRACTOR TO VERIFY LOCATION AND DIRECTION OF UNDERSLAB
LINES PRIOR TO REMOVAL OF CONCRETE.
PROVIDE MOLD-RESISTENT GYPSUM BOARD. WHERE ADJACENT TO NEW
AND EXISTING PLUMBING FIXTURES.
REMOVE ALL EXISTING WATER CLOSET/SHOWER ACCESSORIES,
INCLUDING THOSE THAT ARE EXISTING TO REMAIN, CLEAN AND THEN
REINSTALL IN THE SAME LOCATION OR AS SHOWN AS NEW WORK PLAN.
LOCATE PER MOUNTING HEIGHTS DIAGRAM.
GENERAL NOTES
PLAN LEGEND
TILE FLOORINGDEMO TILE FLOORING
KEYNOTE
DIMENSION TO FACE OF FRAMING
X
NOT IN SCOPE
ADA CLEARANCES
X
SHOWER/TOILET ACCESSORIES TAGS - SEE A0022
6 6
12 12
11 11
18 18
8" 3'-4"
VERIFY IN FIELD
4 4
4 4
MENS RESTROOM
WOMENS RESTROOM
WOMENS NORTH SINK/OUTLET MENS NORTH SINK MENS NORTH water closet NORTH SHOWER CONDITION NORTH DRINKING FOUNTAINS WOMENS SOUTH SINK WOMENS SOUTH water closet MENS SOUTH water closet MENS SOUTH SOUTH SHOWER, TYPICAL
REVISIONS
6/13/2025 10:48:20 AM
RESTROOM DEMO AND
PROPOSED
FLOORPLANS
A001 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
E
AS
T
C H
IP
M
AN
R
D . P
H O
EN
IX
, A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
1/4" = 1'-0"A001
1 ENLARGED NORTH RESTROOM - DEMO
1/4" = 1'-0"A001
2 ENLARGED NORTH RESTROOM - NEW WORK
1/4" = 1'-0"A001
4 ENLARGED SOUTH RESTROOM - NEW WORK
19 AREA OF SHOWER TO HAVE NEW TILE INSTALLED TO MATCH THE REST OF ROOM.
IN SHOWER AREA, SLOPE NEW FINISH TOWARDS REPAIRED DRAIN. INSTALL NEW
PLUMBING FIXTURES, GRAB BARS AND SHOWER SEAT AT LOCATION OF
EXISTING. SHOWER SEAT BASIS OF DESIGN: BOBRICK B-5181 REVERSIBLE
L-SHAPED FOLDING SHOWER SEAT.
20 NEW POWDER-COATED TOILET STALL PARTITION, COLOR TO MANUFACTURER'S
STANDARD COLOR CLOSEST TO EXISTING PARTITIONS. SEE SPECS FOR
ADDITIONAL INFORMATION
21 NEW PARTITION WALLS TO BE 3-5/8" METAL STUDS AT 16" OC WITH 5/8" GYPSUM
WALLBOARD BOTH SIDES EXCEPT WHERE TILE IS TO BE MOUNTED ON TILE
BACKER BOARDS INSTEAD OF GYPSUM BOARD. FILL WALL CAVITY WITH SOUND
ATTENUATING BATT INSULATION.
22 NEW URINAL TO BE INSTALLED PER MOUNTING HEIGHTS LEGEND. SEE PLUMBING
DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION.
23 NEW LAMINATE COUNTERTOP TO BE SUPPORTED BY EVENLY SPACED COUNTER
BRACKETS AT 3' MAX OC. BRACKETS ARE TO MAINTAIN ADA CLEARANCES.
24 NEW WATER CLOSET FIXTURE TO BE INSTALLED PER MOUNTING HEIGHTS
LEGEND. SEE PLUMBING DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION.
25 NEW SHOWER INSERT, SHOWER SEAT, AND WALL MOUNTED GRAB BARS. SEE
PLUMBING DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION. INSTALL
BLOCKING IN WALLS AT LOCATION OF ANY WALL MOUNTED ITEMS.
26 NEW 36" WIDE HOLLOW METAL DOOR IN HOLLOW METAL FRAMES. SEE DOOR
SCHEDULE ON A003 FOR ADDITIONAL INFORMATION ON DOORS AND HARDWARE.
27 FLOORING IN ROOM TO BE PORCELAIN TILE TO REPLACE EXISTING CERAMIC
TILE. BASIS OF DESIGN: DALTILE PORTFOLIO 12x24 AND 2x2 WITH COVE BASE, NOCE PF11.
28 NEW PARTITION WALLS TO BE 3-5/8" METAL STUDS AT 16" OC WITH 5/8" GYPSUM
WALLBOARD BOTH SIDES EXCEPT WHERE TILE IS TO BE MOUNTED ON TILE
BACKER BOARDS INSTEAD OF GYPSUM BOARD. VERIFY SPACING WITH URINAL
WALL CARRIER. SEE WITH PLUMBING DRAWINGS AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
29 NEW COUNTER MOUNTED SINK. SEE PLUMBING DRAWINGS AND SPECS FOR
ADDITIONAL INFORMATION.
30 NEW DRINKING FOUNTAIN WITH BOTTLE FILLER. SEE PLUMBING DRAWINGS AND
SPECS FOR ADDITIONAL INFORMATION.
31 NEW 36" WIDE HOLLOW METAL DOOR IN METAL FRAMES. DOOR TO HAVE CLOSER
AND PASSAGE HARDWARE WITH DEADBOLT FOR OCCUPANT PRIVACY THAT
INCLUDES COLORED OCCUPANCY INDICATOR. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
32 NEW BENCH MOUNTED TO FLOOR ADJACENT TO WALL. BENCH TO BE 42" MIN
LENGTH, 20" DEEP (24" MAX), AND SEAT TO BE 18" ABOVE FINISH FLOOR. SECURE
BENCH TO FLOOR/WALL WITH BOLTS OR AS OTHERWISE RECOMMENDED BY
MANUFACTURER.
33 PROVIDE TRANSITION STRIP UNDER DOORWAY WHERE NEW TILE FLOORING
MEETS EXISTING CONCRETE FLOORING IN THE HALLWAY.
34 AFTER COMPLETING PLUMBING WORK, PATCH/REPAIR CONCRETE SLAB PER
STRUCTURAL DRAWINGS AND PREP ROOM FOR NEW FLOORING PER
MANUFACTURER'S RECOMMENDATIONS.
35 NEW RESTROOM SIGNAGE TO MATCH EXISTING SIGNAGE THROUGHOUT
BUILDING. ALL THREE SIGNS TO HAVE ROOM NAMING AND NUMBERING VERIFIED
WITH GOVERNMENT. ROOM NAMING AND NUMBERING WILL VARY WITH EACH
SIGN.
36 NEW GRAB BARS ARE TO BE INSTALLED PER MOUNTING HEIGHTS LEGEND.
37 NEW TOILET PAPER DISPENSER IN LOCATION OF EXISTING WHICH SHOULD BE
REMOVED AND DISPOSED, SEE ACCESSORIES SCHEDULE.
# NEW WORK KEYNOTES
1/4" = 1'-0"A001
3 ENLARGED SOUTH RESTROOM DEMO
# DEMOLITION KEYNOTES
1 SAWCUT FLOORING AS NECESSARY TO COMPLETE PLUMBING WORK IN THIS AREA
THEN PATCH BACK. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
2 REMOVE EXISTING WATER CLOSET FIXTURES AND PREP FOR INSTALLATION OF
NEW WATER CLOSET FIXTURE IN SAME LOCATION. SEE PLUMBING DRAWINGS FOR
FULL SCOPE OF WORK.
3 EXISTING DOOR AND HARDWARE TO REMAIN. PROTECT IN PLACE DURING
CONSTRUCTION OR REMOVE AND REINSTALL.
4 EXISTING SOAP AND PAPER TOWEL DISPENSERS TO BE RE-USED. GOVERNMENT
REMOVE AND SAVE FOR REINSTALLATION IN SAME GENERAL LOCATION PER
MOUNTING HEIGHTS LEGEND.
5 REMOVE EXISTING DRINKING FOUNTAIN AND PIPING IN WALL. SEE PLUMBING
DRAWINGS FOR FULL SCOPE OF WORK.
6 REMOVE EXISTING WATER CLOSET STALL PARTITIONS AND DISPOSE OFF SITE.
7 REMOVE EXISTING URINAL AND PREP FOR INSTALLATION OF NEW FIXTURE IN
SAME PLACE. SEE PLUMBING DRAWINGS FOR FULL SCOPE OF WORK.
8 REMOVE EXISTING SINKS, COUNTERTOP, AND BRACKETS AND PREP AREA FOR
PLUMBING WORK.
9 EXISTING TILE FLOORING REMOVED IN ENTIRE ROOM TO ACCOMMODATE SLAB
CUTTING WORK AS REQUIRED FOR PLUMBING SCOPE. AFTER INFILL OF SLAB
CUTTING WORK (PER DETAIL), PREP ENTIRE FLOOR SURFACE FOR INSTALLATION
OF NEW TILE PER MANUFACTURER'S INSTRUCTIONS.
10 REMOVE EXISTING FAUCET, TILE, AND WALL MOUNTED SHOWER SEAT IN SHOWER.
PREP AREA FOR DRAIN WORK AS REQUIRED. AFTER COMPLETION OF DRAIN
WORK, PREP AREA FOR NEW FIXTURES/FINISHES. SEE PLUMBING DRAWINGS FOR
FULL SCOPE OF WORK.
11 REMOVE EXISTING DOOR AND FRAMES.
12 REMOVE PORTION OF EXISTING STUD WALLS AND GYPSUM FINISH ENTIRELY
WHERE SHOWN DASHED IN ORDER TO RECONFIGURE WALLS AS SHOWN IN NEW
WORK PLAN.
13 AREA OF EXISTING URINAL STALL. URINAL PREVIOUSLY REMOVED AND WALL
CAVITY OPENED UP. REMOVE EXISTING URINAL CARRIER FROM WALL PRIOR TO
STARTING NEW WORK.
14 REMOVE EXISTING LOCKERS WHICH ARE LOCATED IN AREA OF PLANNED NEW
URINAL. CUT LOCKER TOP CAPS AS NECESSARY TO FIT NEW WIDTH OF LOCKERS.
15 EXISTING FLOOR DRAIN IN LAMINATE TILES IN HALLWAY TO REMAIN.
16 EXISTING STALL PARTITION TO REMAIN. REMOVE AND REINSTALL AS NEEDED
DURING CONSTRUCTION IN ORDER TO COMPLETE PLUMBING WORK. SEE
PLUMBING FOR ADDITIONAL INFORMATION.
17 EXISTING LOCKERS TO REMAIN. REMOVE AND REINSTALL AS REQUIRED TO
COMPLETE SCOPE OF WORK AS SHOWN IN ARCH AND PLUMBING DRAWINGS.
18 EXISTING GRAB BARS TO REMAIN. VERIFY COMPLIANCE WITH REQUIRED
MOUNTING HEIGHTS. WHERE FOUND NOT TO BE IN COMPLIANCE, REMOVE AND
REINSTALL AT CORRECT HEIGHTS.
NOT TO SCALEA001
5 SITE PHOTOS - FOR GENERAL CONTEXT ONLY
NORTH REFNORTH REF
NORTH REF NORTH REF
FIRE PROTECTION GENERAL NOTE:
GENERAL CONTRACTOR TO ENGAGE A REGISTERED DESIGN
PROFESSIONAL, PER THE INTERNATIONAL FIRE CODE SECTION 106.1 (IBC
SECTION 107), TO PROVIDE CONSTRUCTION DOCUMENTS/PRELIMINARY
WORKING PLANS FOR ALL REQUIRED MODIFICATIONS TO THE EXISTING
FIRE PROTECTION SYSTEMS IF REQUIRED BY THE FIRE CODE OFFICIAL.
GENERAL CONTRACTOR IS TO ENGAGE FIRE SPRINKLER AND FIRE ALARM
CONTRACTORS TO PROVIDE SHOP DRAWINGS/WORKING PLANS PER THE
INTERNATIONAL BUILDING CODE SECTION 106.2 (IBC SECTION 107) AND
INSTALLATION PER THE REFERENCED INSTALLATION STANDARDS (NFPA)
OF THE INTERNATIONAL FIRE CODE, CHAPTER 9. SYSTEMS WITH NO
ADDITIONAL SPRINKLER ADDITIONS OR CHANGE OF NFPA 13 FIRE HAZARD
OCCUPANCY WILL NOT REQUIRE CALCULATIONS PER NFPA 13.
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
Tectonic Copyright 2007Tectonic Copyright 2007
TB1
P1
VERIFY PRIOR TO ORDERING
LAM
2' -9
/2
M U
M U
M U
PTSDSD
3' -3
/2
C L 7'
-0
CG1
TB1
P1
BN
CG1 CG1
3 TB1
P1
SCG
B2
G B3
G B1
TB1
SN
3' -6
"8" 1'-4"
2'-2"
3' -6
M
O U
N
TE
D
8" M
AX
G B1
G B4
P1
2' -1
0"
EQ4'-6"EQ
G B5
" M
IN
CURT
H O
O K
7' -6
TP
TB1
P1
PT
1'-6"
TB1
P1
M U
3' -0
2' -1
0"
3' -4
6'
-8
SH
EL
FSDPT G
B2
1'-4"
LATCH SIDE
WOMEN MEN
" A
.F .F
C L
M U
SD SDM
U
M U
PT
VERIFY PRIOR TO ORDERING
1' -5
TB1
P1
LAM
2' -9
/2
2 4
CL 1'-7"
C L
7' -0
CG1
TB1
P1
BN
CG1 CG1
VERIFY PRIOR TO ORDERING
M U
M U
M U
SDSD
2' -9
/2
PT
TB1
P1
LAM9
5 10
C L
7' -0
2' -9
/2
3' -4
1' -5
30" MIN
TB1
P1
LAM
M U
M U
PT SD
4 1
VERIFY PRIOR TO ORDERING
C L 7'
-0
DIM# MOUNTING HEIGHTFIXTURE
GRAB BAR
URINAL
TOILET (ADA)
URINAL (ADA)
SINK (ADA)
TOILET
TOILET (ADA)
GRAB BAR (ADA)
TOILET PAPER HOLDER
GRAB BAR
GRAB BAR
GRAB BAR
MIRROR
TOILET PAPER HOLDER
TOILET PAPER HOLDER
SINK (ADA)
SINK (ADA)
A B C C D E1
G H H J K L M N O P Q
18" VERTICAL GRAB BAR
18" VERTICAL GRAB BAR
R S
6" MAX TO CENTER FROM ADJACENT WALL
16" - 18" TO CENTER FROM ADJACENT WALL
24" TO RIM ABOVE FINISH FLOOR
17" TO RIM ABOVE FINISH FLOOR
34" MAX TO SINK RIM ABOVE FINISH FLOOR
6" DEEP MAX TOE CLEARANCE
27" HIGH MIN KNEE CLEARANCE
14" TO TOP OF SEAT
17" - 19" TOP OF SEAT
12" TO CENTER FROM ADJACENT WALL
7" - 9" TO CENTERLINE FROM TOILET
33" - 36" TO TOP A.F.F.
36" OUTSIDE TO OUTSIDE
42" OUTSIDE TO OUTSIDE
40" MAX TO BOT OF MIRROR SURFACE
19" MIN. TO CENTER ABOVE FINISH FLOOR
1 1/2" MIN. FROM BOTTOM OF GRAB BAR
39" - 41" FROM WALL
39" - 41" FROM FLOOR
NOTE: THIS ELEVATION IS REPRESENTATIVE OF TYPICAL FIXTURE MOUNTING
HEIGHTS AND CLEARANCES. REFER TO PLANS FOR FIXTURES TO BE INSTALLED.
H P
K S
Q
E1
E2
D N
C
V W
T U
SHOWER CONTROLS
SHOWER CONTROLS
SHOWER CONTROLS
SHOWER CONTROLS
T U V W
38" MIN. TO BOTTOM ABOVE FINISH FLOOR
48" MAX. TO TOP ABOVE FINISH FLOOR
16" MIN FROM SEAT WALL
27" MAX FROM SEAT WALL
15" MAX FROM CENTERLINE
SHOWER CONTROLS
Y
PLUMBING FIXTURE AND
TOILET ACCESSORY MOUNTING HEIGHTS
ROLL-IN-TYPE
X
T U
TRANSFER
-TYPE
SHOWER SEAT
X
17" - 19" TOP OF SEAT
CL
4'
6"
2' - 0"
3'
0"
3'
8"
3'
4"
4'
0"
5'
0"
MIRROR
UNIT
PAPER
TOWEL
DISPENSER
TOILET SEAT
COVER
DISPENSER
HAND SOAP
DISPENSER
ROBE
HOOK
MOP AND BROOM
HOLDER WITH
UTILITY SHELF
OJ
M R L
A
B
SINK (ADA) F1 8" DEEP MIN KNEE CLEARANCE
Y
F1
GF2
SINK (ADA) F2 11" DEEP MIN KNEE CLEARANCE
SINK (ADA) E2 9" HIGH MIN TOE CLEARANCE
A.
B.
C.
D.
E.
F.
G.
H.
I.
FIELD VERIFY ALL EXISTING CONDITIONS AND ALERT
ARCHITECT/ENGINEERS OF ANY DISCREPANCIES BETWEEN DRAWINGS
AND SITE CONDITIONS.
EXISTING GYPSUM WALLS WHICH ARE TO REMAIN ARE TO BE CLEANED,
PATCHED, AND REPAIRED AS REQUIRED FOR UNIFORM FINISH IN ENTIRE
ROOM. ALL WALLS ARE TO BE PAINTED TO MATCH THE EXISTING PAINT
COLOR IN ROOM.
CEILING GYPSUM FINISH IN BOTH EXISTING RESTROOMS ARE TO BE
COMPLETELY REMOVED TO ACCOMMODATE PLUMBING WORK.
FOLLOWING PLUMBING WORK, NEW GYPSUM SHOULD BE INSTALLED IN
ROOMS, UTILIZING THE EXISTING CEILING FRAMING, EXCEPT WHERE
FRAMING IS REQUIRED TO BE ADJUSTED FOR NEW SHOWER ROOM
LAYOUT. PAINT GYPSUM CEILINGS TO MATCH EXISTING CEILINGS AND
WALLS.
LIGHTING FIXTURES IN RESTROOMS ARE TO BE REMOVED AND NEW LED
FIXTURES INSTALLED IN THE SAME LOCATIONS. SEE ELECTRICAL
CEILING PLANS ON E001 FOR ADDITIONAL INFORMATION.
PROVIDE LAVATORY GUARDS UNDER SINKS ANYWHERE PIPING IS
EXPOSED TO VIEW IN ROOM, TYPICAL OF ALL SINKS IN AREAS OF WORK.
PROVIDE (2) EXTRA LAV GUARDS TO GOVERNMENT UPON COMPLETION
OF WORK.
PROVIDE BLOCKING IN WALLS AT ANY NEW WALL MOUNTED EQUIPMENT
AND EQUIPMENT THAT IS BEING REPLACED, THIS INCLUDES: COUNTER
BRACKETS, GRAB BARS, HOOKS, water closet ACCESSORIES, ETC
SLAB CUTTING AND REMOVAL OF CONCRETE IS TO BE KEPT AS MINIMAL
AS POSSIBLE TO COMPLETE WORK AS SHOWN IN PLUMBING DRAWINGS.
CONTRACTOR TO VERIFY LOCATION AND DIRECTION OF UNDERSLAB
LINES PRIOR TO REMOVAL OF CONCRETE.
PROVIDE MOLD-RESISTENT GYPSUM BOARD. WHERE ADJACENT TO NEW
AND EXISTING PLUMBING FIXTURES.
REMOVE ALL EXISTING WATER CLOSET/SHOWER ACCESSORIES,
INCLUDING THOSE THAT ARE EXISTING TO REMAIN, CLEAN AND THEN
REINSTALL IN THE SAME LOCATION OR AS SHOWN AS NEW WORK PLAN.
LOCATE PER MOUNTING HEIGHTS DIAGRAM.
GENERAL NOTES
1/4" = 1'-0"A002
1 WOMENS SOUTH RESTROOM - 171
1/4" = 1'-0"A002
2 WOMENS SOUTH RESTROOM - 171
1/4" = 1'-0"A002
9 SOUTH SINGLE - NORTH
1/4" = 1'-0"A002
10 SOUTH SINGLE - EAST
1/4" = 1'-0"A002
7 SOUTH SINGLE - SOUTH
1/4" = 1'-0"A002
8 SOUTH SINGLE - WEST
REVISIONS
6/13/2025 10:48:25 AM
INTERIOR ELEVATIONS
AND LEGENDS
A002 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
E
AS
T
C H
IP
M
AN
R
D . P
H O
EN
IX
, A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
# KEYNOTES
MATERIALS LIST
ITEM NO PRODUCT TYPE MANUFACTURER DESCRIPTION COLOR SIZE NOTES
BASE
TB1 TILE BASE DALTILE PORTOFINO STYLE COVE BASE NOCE PF11 6" x 12" INSTALL PER MANUFACTURER'S RECOMMENDATIONS
COUNTER
LAM LAMINATE COUNTER FORMICA BLACK SHALESTONE MATTE FINISH. APRON AND BACKSPLASH TO MATCH 9527-58 COUNTERS ARE TO HAVE MATCHING 4" BACKSPLASH AND 4" APRON. VERIFY APRON DOES NOT
CONFLICT WITH REQUIRED CLEAR KNEE SPACE WHEN INSTALLED.
FLOOR
CT1 TILE FLOOR DALTILE PORTOFINO STYLE FLOOR/WALL TILE NOCE PF11 2" x 2" INSTALL AROUND NEW AND EXISTING DRAINS AND FIXTURES IN ROOM
EP1 EPOXY FLOORING
FINISH
- MATCH THICKNESS TO ADJACENT MATCH TO COLOR AND
FINISH OF ADJACENT
SC1 SEALED CONCRETE - SEALED CONCRETE FLOORING FINISH CLEAR - INSTALL SEALANT PER MANUFACTURER'S RECOMMENDATIONS
WALL
P1 PAINT SHERWIN WILLIAMS CEILING TO BE SATIN FINISH, WALLS TO BE SEMI-GLASS FINISH MATCH EXISTING - PAINT TO BE ANTI-MICROBIAL. PAINT WALLS AND CEILINGS SAME COLOR
WALL PROTECTION
CG1 CORNER GUARD INPRO 48" TALL, 16 GAUGE STANDARDS CORNER GUARD WITH 2" WING TBD MECHANICALLY FASTENED, SELECT MANUFACTURER'S STANDARD COLOR WHICH IS MOST SIMILAR
TO WALL PAINT COLOR
1 EXISTING STALL PARTITION TO REMAIN. REMOVE AND REINSTALL AS NEEDED
DURING CONSTRUCTION IN ORDER TO COMPLETE PLUMBING WORK. SEE
PLUMBING FOR ADDITIONAL INFORMATION.
2 EXISTING LOCKERS ARE TO REMAIN. REMOVE AND REINSTALL AS REQUIRED TO
COMPLETE SCOPE OF WORK AS SHOWN IN ARCH AND PLUMBING DRAWINGS.
3 NEW SHOWER INSERT, SHOWER SEAT, AND WALL MOUNTED GRAB BARS. SEE
PLUMBING DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION. INSTALL
BLOCKING IN WALL AT LOCATION OF ANY WALL MOUNTED ITEMS.
4 NEW URINAL TO BE INSTALLED PER MOUNTING HEIGHTS LEGEND. SEE PLUMBING
DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION.
5 NEW LAMINATE COUNTERTOP TO BE SUPPORTED BY EVENLY SPACED COUNTER
BRACKETS AT 3' MAX OC. BRACKETS ARE TO MAINTAIN ADA CLEARANCES.
BRACKETS BASIS OF DESIGN TO BE MOCKETT SWS4B - 21"X15" MEDIUM BASIS
WORK SURFACE SUPPORT IN BLACK OR APPROVED EQUAL. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
6 NEW TOILET TO BE INSTALLED PER MOUNTING HEIGHTS LEGEND. SEE PLUMBING
DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION.
7 NEW GRAB BARS ARE TO BE INSTALLED PER MOUNTING HEIGHTS LEGEND.
8 NEW POWDER-COATED TOILET STALL PARITION, COLOR TO MANUFACTURER'S
STANDARD COLOR CLOSEST TO EXISTING PARTITIONS. SEE SPECS FOR
ADDITIONAL INFORMATION
9 NEW MIRROR TO BE INSTALLED PER MOUNTING HEIGHT LEGEND, SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION. MIRRORS ARE TO BE
CENTERED ON SINKS. LIGHTS ARE TO BE CENTERED/EQUALLY SPACED ON
COUNTERS OR MIRROR AS SHOWN IN ELEVATIONS AND ELECTRICAL DRAWINGS.
10 AREA OF EXISTING SINK WHICH IS TO BE REMOVED. WALLS ARE TO BE PATCHED
AND REPAIRED AFTER PLUMBING IS REMOVED TO BE FLUSH WITH ADJACENT
WALLS.
11 NEW SHOWER HEAD AND CONTROLS TO BE INSTALLED PER MOUNTING HEIGHTS
LEGEND. SEE PLUMBING DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION.
1/4" = 1'-0"A002
4 MENS SOUTH RESTROOM - 170
1/4" = 1'-0"A002
5 MENS SOUTH RESTROOM - 170
1/4" = 1'-0"A002
3 WOMENS NORTH RESTROOM - 110
1/4" = 1'-0"A002
6 MENS NORTH RESTROOM - 111
ACCESSORIES SCHEDULE
EQ # DESCRIPTION BASIS OF DESIGN PROVIDED BY INSTALLED BY NOTES
BN BENCH SALSBURY 77781-ADA, 42" ADA
BENCH
CONTRACTOR CONTRACTOR
CURT TENSION ROD AND CURTAIN BOBRICK B-6047 ROD + B2043
CURTAINS
CONTRACTOR CONTRACTOR COORDINATE SHOWER CURTAIN FINISH WITH GOVERNMENT, VERIFY WIDTH OF
OPENING PRIOR TO ORDERING TENSION ROD
GB18 GRAB BAR BOBRICK B-9806 FINO SERIES CONTRACTOR CONTRACTOR
GB24 GRAB BAR BOBRICK B-9806 FINO SERIES CONTRACTOR CONTRACTOR
GB36 GRAB BAR BOBRICK B-9806 FINO SERIES CONTRACTOR CONTRACTOR
GB42 GRAB BAR BOBRICK B-9806 FINO SERIES CONTRACTOR CONTRACTOR
GB54 GRAB BAR BOBRICK B-9806 FINO SERIES CONTRACTOR CONTRACTOR
HOOK ROBE HOOK BOBRICK B-9542, SATIN FINISH, CONTRACTOR CONTRACTOR MOUNT AT 42" AFF INTO STUD OR INTO BLOCKING IN WALL
MU MIRROR BOBRICK B-2908 CONTRACTOR CONTRACTOR
PT PAPER TOWEL DISPENSER - RE-USE/GOV CONTRACTOR EXISTING TO BE REINSTALLED, COORDINATE QUANTITY/TYPE WITH GOVERMENT
WHO WILL PROVIDE ANY ADDITIONAL NEEDED ITEMS
SC SEAT COVER DISPENSER BOBRICK B-221 CONTRACTOR CONTRACTOR
SD SOAP DISPENSER - RE-USE/GOV CONTRACTOR EXISTING TO BE REINSTALLED, COORDINATE QUANTITY/TYPE WITH GOVERMENT
WHO WILL PROVIDE ANY ADDITIONAL NEEDED ITEMS
SHELF SHELF BOBRICK B-676 x 24 CONTRACTOR CONTRACTOR MOUNT INTO BLOCKING IN WALL AT LOCATION SHOWN IN ELEVATIONS
SN SANITARY NAPKIN DISPOSAL BOBRICK B-270 CONTRACTOR CONTRACTOR
TP TOILET PAPER <varies> <varies> <varies> <varies>
*ALL NEW ACCESORRIES TO BE STAINLESS STEEL, SATIN FINISH TO MATCH UNLESS OTHERWISE NOTED
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
COORD WITH PLUMBING
EX
IS
TI
N
G
EX
IS
TI
N
G
MATCH EXISTNG
TOP OF CONCRETE SLAB
EXISTING CONCRETE SLAB ON GRADE
#4 x 2'-6" DOWEL WITH 6" EMBED SET IN EPOXY @ 16"
CONCRETE SLAB ON GRADE WITH #4 @ 16" EACH WAY
f'c=4,500 PSI CONCRETE STRENGTH 3% AIR MAX
NOTE:
FIELD COORDINATE FLOOR PENETRATION
SIZES AND LOCATIONS WITH PLUMBING
MATCH EXISTING CONCRETE THICKNESS AND
INSTALL AND SEAL VAPOR BARRIER WHERE
EXISTING BARRIER OCCURS
T T/
LOCATE BAR WITH 1 1/2" CONCRETE COVER FROM
TOP OF SLAB, MIN.
CLEAR FLOOR
SPACE
30" MIN x 48" MIN
TURNING SPACE
60" DIAMETER
17" MIN - 25" MAX
30" MIN
KNEE SPACE
" M
IN
MIN
8"
MAX
6"
9"
3"
FORWARD/SIDE REACH
MOUNTING HEIGHT ZONE
" M
IN
" M
AX
FINISH FLOOR
" M
AX
IF
A T
C O
U N
TE
R
" M
AX
(OBJECTS THAT COMPLY WITH
KNEE SPACE CAN OVERLAP
TURNING SPACE)
" M
IN
30" MIN
" M
IN
R
ADIU
S
STALL SIZE
30" MIN x 48" MIN
" M
IN
60" MIN
16"-18"
CL
17"-19" TO
TOP OF SEAT
1.
2.
3.
4.
I. FIELD VERIFY ALL EXISTING CONDITIONS AND ALERT
ARCHITECT/ENGINEERS OF ANY DISCREPANCIES BETWEEN DRAWINGS AND
SITE CONDITIONS.
II. EXTERIOR REPAIR REFERENCES:
MARICOPA ASSOCIATION OF GOVERNMENTS (MAG) SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION, 2024
AVAILABLE FOR FREE REFERENCE ONLINE
MARICOPA ASSOCIATION OF GOVERNMENTS (MAG) DETAILS FOR
PUBLIC WORKS CONSTRUCTION, 2024
SIDEWALK INFILL DETAIL/SECTION SHALL BE PER MAG DETAIL
NO. 230.
TRENCHING AND CONCRETE/ASPHALT REPAIR SHALL BE
PERFORMED PER MAG SPECIFICATION SECTION 336, “PAVEMENT
MATCHING AND SURFACING REPLACEMENT ”.
TRENCH TYPE FOR PIPE INSTALLATION SHALL BE PER MAG SPEC.
SECTION 336.3
CONCRETE AND ASPHALT REPLACEMENT AND ADJUSTMENTS
SHALL BE PER MAG SPEC. SECTION 336.2.4. ALL NEW PAVEMENT
SHALL MATCH EXISTING ELEVATIONS AND PROVIDE POSITIVE
DRAINAGE.
STRUCTURAL GENERAL NOTES
A.
a.
B.
a.
C.
a.
D.
a.
E.
a.
F.
a.
b.
G.
a.
H.
a.
TRANSITION STRIP
COORDINATE WITH HEIGHT OF FLOORING TRANSITION
INSTALL PER MANUFACTURER'S RECOMMENDATIONS
HINGES
(3) MORTISE HINGES PER DOOR LEAF - STAINLESS STEEL, SATIN
FINISH
DEADBOLT WITH OCCUPANCY INDICATOR
SCHLAGE B571 ON SIDED DEADBOLT WITH COLORED INDICATOR
SATIN FINISH
PUSH PLATE
IVES 8200 PUSH PLATE, 3.5" x 15"
MECHANICALLY FASTENED
MOUNT ALL PLATES AT SAME HEIGHT ABOVE FLOOR
PULL HANDLE
IVES 8302-0 PULL PLATE W/ INTEGRAL HANDLE, 3.5" x 15"
MECHANICALLY FASTENED
MOUNT ALL PLATES AT SAME HEIGHT ABOVE FLOOR
CLOSER
TELL MANUFACTURING DOOR CLOSER, 300 SERIES
MOUNTED AT HEAD OF DOOR AND TO WALL
DOOR STOP - WALL
ROCKWOOD DOOR STOP
MOUNTED AT HEIGHT OF DOOR PULL HANDLE
DOOR HOLD OPEN
ROCKWOOD KICK DOWN STOP WITH RUBBER BUMPER
HARDWARE BASIS OF DESIGN
HARDWARE NOTES
ALL HARDWARE TO BE STAINLESS STEEL UNLESS OTHERWISE NOTED
WITH A SATIN FINISH - INTENT FOR ALL PRODUCTS TO MATCH
INSTALL HARDWARE PER MANUFACTURER'S RECOMMENDATIONS.
INSTALL HARDWARE WITHIN ACCESSIBLE REACH RANGES
COUNTERTOP WITH APRON PER FINISH SCHEDULE
COUNTER BRACKET TO BE INSTALLED PER MANUFACTURER'S
DIRECTIONS. OVERHANG OF COUNTER PAST BRACKET TO NOT
EXCEED MANUFACTURER'S RECOMMENDATIONS. BASIS OF DESIGN
DELTA 'HEAVY DUTY STEEL BRACKET' - COLOR SELECTED BY
GOVERNMENT.
REFERENCE ELEVATIONS AND
MATERIALS LIST FOR FINISHES
VA
R
IE
S
SE
E
EL
EV
AT
IO
N S
BLOCKING IN WALL AT BRACKET MOUNTING POINTS
BRACKETS SHOULD BE LOCATED/SHAPED TO NOT IMPEDE
REQUIRED CLEAR KNEE SPACE (30" WIDE) AT EACH PLUMBING
FITURE - SEE DETAILS ON THIS PAGE
1/2"
25" MAX - TYPICAL AT ALL
3/4" = 1'-0"A003
2 NEW CONCRETE SLAB AT EXISTING
REVISIONS
6/13/2025 10:48:27 AM
DETAILS &
SCHEDULES
A003 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
E
AS
T
C H
IP
M
AN
R
D . P
H O
EN
IX
, A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
1/2" = 1'-0"A003
1 ABA ACCESSIBILITY DIAGRAMS
1 1/2" = 1'-0"A003
3 COUNTERTOP BRACKET DETAILS
DOOR, FRAME AND HARDWARE SCHEDULE
DOOR
NUMBER ROOM NAME
DOOR FRAME
FIRE RATING
HARDWARE
SIZE MTL TYPE NOTES MTL TYPE NOTES THRES HINGE LOCK PUSH PULL CLOSE STOP HOLD NOTESW H T 01 MENS RESTROOM 3'-0" 7'-0" 1 3/4" HOLLOW METAL FLUSH PAINTED HOLLOW METAL 2" FRAME PAINTED - A B - D + E F G H - 02 ALL GENDER SHOWER ROOM 3'-0" 7'-0" 1 3/4" HOLLOW METAL FLUSH PAINTED HOLLOW METAL 2" FRAME PAINTED - A B C D + E F - H - 03 WOMENS RESTROOM 3'-0" 7'-0" 1 3/4" HOLLOW METAL FLUSH PAINTED HOLLOW METAL 2" FRAME PAINTED - A B - D + E F G H -
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
MATCHLINE 2
MATCHLINE 3
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
MATCHLINE 2
MATCHLINE 3
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
M
AT
C H
LI
N
E
MATCHLINE 1
MATCHLINE 3
A001
A001
AREA OF PIT BELOW -
USED TO ACCESS PIPES
8 3/4"
FINISHES LEGEND
NEW CERAMIC TILE FLOORING - SEE PLANS AND MATERIALS LEGEND
EXPOSED CONCRETE, SEALED FINISH WHERE AREA OF SLAB
CUTTING/REPOUR, MATCH TO EXISTING ADJACENT
CT1
SC1
EPOXY FINISHED CONCRETE TO MATCH ADJACENT COLOR AND THICKNESS
FOR AREA OF SLAB CUTTING/REPOUR. EPOXY FINISH TO EXTNED TO
ADJCENT WALLS OR AT CLEAN BREAK - SEE APPROXIMATE AREA SHOWN IN
PLAN.
EP1
FINISHES GENERAL NOTES
A.
B.
C.
D.
E.
F.
G.
FOR MORE INFORMATION ON FINISHES, SEE MATERIALS SCHEDULE ON A002
SEE A001 AND A002 FOR ADDITIONAL INFORMATION ON THE RESTROOM REMODEL
SCOPE AND EXTENT OF FINISHES
SEE A003 FOR NEW SLAB POUR DETAILS AND ASPHALT NEW POUR REFERENCE
DETAILS
REGIONS OF NEW FINISHES SHOWN IN PLAN OUTSIDE THE RESTROOM REMODELS
ARE INTENDED TO SHOW GENERAL AREAS OF WORK. SEE PLUMBING DRAWINGS
FOR FULL EXTENT OF SCOPE WHICH IS TO OCCUR IN THESE AREAS. CONTRACTOR
TO DETERMINE THE EXTENT OF SLAB CUTTING/INFILL/NEW FINISHES WHICH WILL
BE BE REQUIRED TO COMPLETE THE WORK OUTLINED IN PLUMBING DRAWINGS
AND SPECS.
SEE EXISTING BUILDING PHOTOS AND REFERENCE TAGS ON 'P' SHEETS FOR
ADDITIONAL INFORMATION ON THE EXISTING ADJACENT FLOORING THAT IS TO BE
MATCHED IN AREAS OF WORK.
TEST EPOXY FINISH IN ONE AREA TO VERIFY MATCH TO ADJACENT PRIOR TO
COMPLETION OF INSTALLATION OF THAT FINISH THROUGHOUT BUILDING.
ANY WALLS WHICH ARE DAMAGED AS PART OF THE PLUMBING WORK OUTSIDE THE
BATHROOM ARE TO BE PATCHED/REPAIRED AND PAINTED TO MATCH ADJACENT.
EXTERIOR CONCRETE SIDEWALK TO MATCH ADJACENT - ALIGN TOOLED
JOINTS WITH EXISTING - SEE DETAILS/REFERENCE INFO ON A003
EXTERIOR ASPHALT TO MATCH ADJACENT - SEE DETAILS/REFERENCE INFO
ON A003
REVISIONS
6/13/2025 10:48:29 AM
OVERALL FINISH PLAN
A004 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
PL
U
M B
IN
G
S
ER
VI
C
ES
R
EP
A
IR
U
SD
A
AP
H
IS
P
PQ
P
H O
EN
IX
R
EA
R
IN
G F
AC
IL
IT
Y
- A
PH
IS
-M
N -1
E
AS
T
C H
IP
M
AN
R
D . P
H O
EN
IX
, A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | BEHRENS
DRAWN BY | CLARK
REVIEWED BY | ROBERTS
1/16" = 1'-0"A004
1 FIRST FLOOR - ARCH FINISHES INFO
NORTH REF
82820
QUIRAM
FRANCES
Re gist ered Archi tect
CE
RTIFICATENO.
EXISTING PANEL: LC
LOCATION: SEE SHEET A000 AMPS: 125 MINIMUM AIC RATING: EXISTING
TYPE OF MAIN: MLO VOLTAGE: 208Y/120 MOUNTING TYPE: SURFACE
MANUFACTURER: SIEMENS PHASE: 3 NOTES:
MODEL TYPE: S1 WIRES: 4
LOAD NAME
CKT BRK CKT PHASE A
LOAD (VA)
PHASE B
LOAD (VA)
PHASE C
LOAD (VA)
CKT BRK CKT
LOAD NAMENOTES POLE AMP NO NO AMP POLE NOTES
(E) REC (6) 1 20 1 180 1080 2 20 1 (E) REC (6) EGG PREP ALARM
(E) TMB 1 20 3 800 180 4 20 1 (E) REC (7)
(E) REC W/150 (2) AUTOCLAVE 1 20 5 360 180 6 20 1 (E) REC (6)
(E) WASHER RM 162 1 20 7 180 180 8 20 1 (E) REC (7) & E.F.-2
(E) FC-7 (2)1/6HP 1 20 9 600 1200 10 20 1 (E) FC-RM 195 & 201
(E) FC-7 (2)1/6HP 1 20 11 600 600 12 20 1 (E) EF-1
(E) FC-14 & FC-15 1 20 13 1200 1000 14 20 1 (E) AIR DOOR RM 306
(E) FC-15 & FC-1 1 20 15 1200 180 16 20 1 (E) TIME CLOCK PHOTO CELL
(E) FC-13 & FC-61 1 20 17 1200 180 18 20 1 (E) REC @ 164
(E) HIGH PRESSURE WASHER 1 30 19 1080 180 20 20 1 (E) REC @ 164
(E) AIR, BUBBLE MOTOR 1 30 21 1080 180 22 20 1 (E) REC @ 164
(E) NE GATE 2 15 23 900 180 24 20 1 (E) REC @ 164
*** * ** 25 900 180 26 20 1 RESTROOM RECEPTACLE (NOTE A)
(E) NW GATE 2 15 27 900 1200 28 35 2 EXISTING LOAD
*** * ** 29 900 2160 30 ** * ***
6160 7520 7260 TOTAL CONNECTED PHASE VA
51.3 62.7 60.5 TOTAL CONNECTED PHASE AMPS
LOAD CLASSIFICATION CONNECTED LOAD(kVA) FACTOR DEMAND LOAD PANEL TOTALS
LIGHTING 0.0 PER NEC 210.20(A) 0.0 CONNECTED LOAD(kVA): 20.9
CONVENIENCE OUTLETS 12.2 PER NEC 220.44 11.1 CONNECTED AMPS: 58.2
MOTORS 4.2 PER NEC 430.24 4.7
KITCHEN EQUIPMENT 0.0 PER NEC 220.56 0.0 DEMAND LOAD (kVA): 21.4
ELECTRIC HEAT 0.0 100% 0.0 DEMAND AMPS 59.5
WATER HEAT 0.0 100% 0.0
MISCELLANEOUS 4.5 PER NEC 210.20(A) 5.7
CIRCUIT NOTES:
A. CONNECT TO EXISTING CIRCUIT BREAKER.
ABOVE COUNTER, 4" BACK SPLASHAC
AUTOMATIC TRANSFER SWITCHATS
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
BELOW GRADEBLG
BOTTOM OF DEVICEBOD
CONDUITC
LAY-IN OR RECESSED FIXTURE, SIZE ON PLANS
WALL MOUNTED FIXTURE, SIZE ON PLANS
SURFACE MOUNTED FIXTURE, SIZE ON PLANS
PENDANT OR SURFACE MOUNTED FIXTURE,
SIZE ON PLANS
RECESSED DOWNLIGHT FIXTURE
SURFACE MOUNTED FIXTURE
WALL MOUNTED FIXTURE
CEILING MOUNTED, WALL MOUNTED EXIT
LIGHT (W/ DIRECTIONAL ARROWS)
PENDANT MOUNTED FIXTURE, SIZE ON PLANS
SHADED FIXTURE INDICATES FIXTURE IS UNSWITCHED
AND ALSO INDICATES EMERGENCY POWER.
CARD ACCESS SYSTEMCAS
CLOSED CIRCUIT TVCCTV
CEILINGCLG
CENTER OF DEVICECOD
COPPERCU
HOME RUN TO PANEL. MINIMUM 2#12 AND 1#12GND OR AS
NOTED ON DRAWINGS
CONDUIT CONCEALED IN CEILING OR WALL
CONDUIT CONCEALED UNDER FLOOR
SWITCH - SPST
2 SINGLE POLE, DOUBLE THROW
3 THREEWAY
4 FOURWAY
K KEY OPERATED
P PILOT LIGHT
WP WEATHERPROOF
OS OCCUPANCY SENSOR
D DIMMER
ED ELECTRIC DEFROST(RE: REFRIGERATION POWER PLAN)
MC SPOT-MOMENTARY CONTACT
LV LOW VOLTAGE
T TIMER SW ITCH
TS TEST SWITCH
VS VACANCY SENSOR
RECEPTACLE - DUPLEX
GFI RECEPTACLE - DUPLEX (GROUND FAULT
INTERRUPT)
USB DEVICE RECEPT W/2 USB PORTS
DC DROP CORD
WP WEATHERPROOF COVER & WEATHER
RESISTANT RECEPTACLE
TR TAMPER RESISTANT
S SURGE PROTECTED
IG ISOLATED GROUND
FILLED CENTER INDICATES UPS RECEPTACLE
RECEPTACLE - DOUBLE DUPLEX
GFI RECEPTACLE - DOUBLE DUPLEX
- SAME INDICATORS AS SHOWN FOR DUPLEX
RECEPTACLE
RECEPTACLE - 208V
R RANGE - NEMA 14-50R
D DRYER - NEMA 14-30R
W WELDER - NEMA 14-50R
* NEMA CONFIGURATION AS NOTED
208V RECEPTACLE IN RECESSED FLOORBOX
DUPLEX RECEPTACLE/GFI IN RECESSED FLOORBOX
DOUBLE DUPLEX RECEPTACLE/GFI IN
RECESSED FLOORBOX
J-BOX - BOX INDICATES FLOOR MOUNTING
-4"X4"X2-1/8" DEEP UNLESS OTHERWISE NOTED
RECEPTACLE - DUPLEX, MOUNTING IN CEILING
EXISTING PANELBOARD, SURFACE MOUNTED
J JJ
CLG
PANELBOARD, SURFACE MOUNTED
CLG
GFI RECEPTACLE - DUPLEX, MOUNTING IN CEILING
SYMBOL DESCRIPTION
ABBREVIATIONS AND MISCELLANEOUS SYMBOL DESCRIPTION SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS
RECEPTACLE - DUPLEX, CONTROLLED
GFI RECEPTACLE - DUPLEX, CONTROLLED
BREAKERBKR
CIRCUITCKT
BOTTOM OF FIXTUREB.O.F.
CASE CONTROLLER MODULECCM
CASE FANCF
DIGITAL VIDEO RECORDERDVR
EXISTING(E)
ELECTRICAL CONTRACTOREC
EXHAUST FANEF
GENERAL CONTRACTORGC
MECHANICAL CONTRACTORMC
NEUTRALN
NIGHT LIGHTNL
PAN-TILT-ZOOMPTZ
QUANTITYQTY
RELOCATED(R)
SURFACESF
TELECOMMUNICATIONS MAIN GROUNDING BUS BARTMGB
TELECOMMUNICATIONS BONDING BACKBONETBB
TOE KICK RECEPTACLETK
TELEPHONE TERMINAL BOARDTTB
TYPICALTYP
UNDERGROUNDUG
UNLESS OTHERWISE NOTEDUON
WITHW/
WIRE MOLDW M
WEATHER RESISTANT (WHILE IN USE)WR
TRANSFORMERXFMR
SWITCH DESIGNATIONa,b,c etc
CIRCUIT DESIGNATION, PANEL BN1L, CIRCUITS 2,4,6BN1L-2,4,6
INDICATES DETAIL 1 ON SHEET E5011/E501
NEW(N)
OVER CURRENT PROTECTIONOCP
TEMPERATURE CONTROL CONTRACTORTC
RELOCATED EXISTING(RE)
ELECTRIC DEFROSTED
DEMOLISH(D)
DEMOLISH RELOCATED EQUIPMENT(D/R)
OCCUPANCY SENSOR, CEILING MOUNTED.
SENSOR SWITCH NO CMR-PDT-9-BAA OR
EQUAL
OS
OS
OCCUPANCY SENSOR, WALL MOUNTED.
SENSOR SWITCH NO WSX-PDT-WH-BAA OR
EQUAL
FINISHED CEILING
FINISHED FLOOR
BOD
BOD
BOD
COD
COD
AC = ABOVE COUNTER, MINIMUM 4" ABOVE
BACKSPLASH TO BOTTOM OF DEVICE.
48" TOD IS ACCEPTABLE FOR CMU BLOCK
CONSTRUCTION.
M
IN
IM
U M
T O
B O
T T
O M
O F
D E
V
IC
E
M O
U N
T
A
B O
V E
D O
O R
F R
A M
E
T
O T
O P
O F
T R
IM
M
IN
IN
H A
Z A
R D
O U
S L
O C
A T
IO
N
S -T
O B
O T
T O
M O
F C
A N 8
A F
F T
O B
O T
T O
M O
F D
E V
IC
E
O R
B E
L O
W C
E
IL
IN
G
T O
T O
P O
F D
E V
IC
E
W H
IC
H
E V
E R
I S
L O
W E
R
C S
KPS
D
PANEL
BOARD
W
T CO₂
REVISIONS
6/19/2025 1:43:42 PM
ELECTRICAL LEGENDS
E001 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
P L
U M
B
IN
G S
E R
V
IC
E S
R E
P A
IR
U S
D A
A P
H
IS
P P
Q P
H O
E N
IX
R
E A
R
IN
G F
A C
IL
IT
Y
A P
H
IS
-M N
-1
E A
S T
C H
IP
M
A N
R D
P
H O
E N
IX
A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | GROSS
DRAWN BY | GROSS
REVIEWED BY | VICTORINO
ELECTRICAL DEVICES AND SYMBOLSINTERIOR BOX MOUNTING HEIGHTSELECTRICAL ABBREVIATIONS
GENERAL NOTES:
A) CONTRACTOR TO COORDINATE FINAL FIXTURE MOUNTING LOCATION AND HEIGHTS WITH ALL OTHER TRADES PRIOR TO ROUGH-IN.
B) ALL LIGHTING SHALL BE BAA QUALIFIED.
NOTES:
1) PROVIDE WITH INTEGRAL EMERGENCY BATTERY. CONNECT EMERGENCY BATTERY TO UNSWITCHED LEG OF RESPECTIVE AREA LIGHTING CIRCUIT
LIGHTING FIXTURE SCHEDULE
FIXTURE MOUNTING
HEIGHT TO
B.O.F.
FIXTURE LIGHT SOURCE
TYPE DESCRIPTION MANUFACTURER
CATALOG NUMBER
MOUNTING TYPE
VOLTAGE VA
LAMP
TYPE
CRI KELVIN LUMENS NOTES
LOCATION TYPE
C2 4" LED CAN LIGHT - SHOWER GOTHAM EV04SH-35/15-DFR-SOL-MVOLT-EZ1 CEILING RECESSED - 120 V 13.70 LED 80 3500K 1500 lm
L1 4' LED SURFACE WRAP LITHONIA LBL4-4000LM-80CRI-3500K-MVOLT CEILING SURFACE - 120 V 32.40 LED 80 3500K 4000 lm
L1E 4' LED SURFACE WRAP - EMERGENCY LITHONIA LBL4-4000LM-80CRI-3500K-MVOLT-E7W CEILING SURFACE - 120 V 32.40 LED 80 3500K 4000 lm 1
V2 2' LED VANITY FIXTURE LITHONIA FMVCSLS-24IN-MVOLT-30K35K40K-90CRI-BN-M6 WALL SURFACE 6'-8" 120 V 27.00 LED 90 3500K 1550 lm
V4 4' LED VANITY FIXTURE LITHONIA FMVCSLS-48IN-MVOLT-35K-90CRI-BN-M4 WALL SURFACE 6'-8" 120 V 36.00 LED 90 3500K 2960 lm
06/19/2025
OS OS
OSOS
OS
O S
O S
NO WORKLJ-14
LJ-14
MENS
RESTROOM
WOMENS
RESTROOM
LJ-21
LJ-19
+42"
2 2
LC-26
LC-8 LC-8
MENS
RESTROOM
WOMENS
RESTROOM
ALL GENDER
SHOWER
ROOM
C2
V2
V4
V4V4
V4
L1 L1
L1EL1E
L1E
1 1
4 4
5 5
MENS
RESTROOM
WOMENS
RESTROOM
ALL GENDER
SHOWER
ROOM
A. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL
EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL AND PLUMBING
DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH
ARCHITECTURAL AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS
REQUIRED BY THE CONTRACTOR.
B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED IN WALLS, FUR
OUTS, AND ACCESSIBLE CEILINGS. USE OF SURFACE MOUNTED RACEWAYS
MUST BE APPROVED BY THE ARCHITECT FOR EACH LOCATION. WHERE
APPROVED, UTILIZE WIREMOLD OR APPROVED EQUAL SURFACE MOUNTED
RACEWAYS PAINTED TO MATCH SURROUNDING WALLS.
C. WHERE NEW DEVICES ARE SHOWN FOR INSTALLATION ON EXISTING WALLS,
ELECTRICAL CONTRACTOR IS RESPONSIBLE TO COORDINATE CUTTING,
PATCHING, AND REPAIR OF EXISTING WALL WITH OTHER TRADES AS REQUIRED
TO PROVIDE FLUSH MOUNTED INSTALLATION.
D. ALL DASHED ITEMS ON DEMOLITION PLANS ARE TO BE REMOVED, AND SOLID
ITEMS ARE TO REMAIN UNLESS NOTED OTHERWISE OR TO BE RELOCATED AS
NOTED. NOTE - ITEMS SHOWN IN THE DEMOLITION PLANS ARE BASED ON FIELD
OBSERVATIONS.
E. ADDITIONAL ELECTRICAL ITEMS MAY BE ENCOUNTERED THAT ARE NOT SHOWN -
ALL GENERAL ELECTRICAL ITEMS ARE TO BE REMOVED THAT ARE NOT SHOWN,
BUT ARE IN AREAS OF COMPLETE REMODEL.
F. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF REQUIRED
PATCHING AND PAINTING WITH THE GENERAL CONTRACTOR.
G. CONNECTIONS FOR ITEMS SHOWN FOR DEMOLITION SHALL BE REMOVED BACK
TO SOURCE, OR TO NEAREST UPSTREAM DEVICE.
H. WHERE EXISTING CONNECTIONS ARE AFFECTED BY DEMOLITION, PROVIDE NEW
CONDUCTORS, RACEWAYS, ETC., AS REQUIRED TO MAINTAIN OPERATION OF
EXISTING ITEMS WHICH ARE TO REMAIN.
I. EXISTING CONDUITS IN THE FLOOR W HICH ARE NOT USED AND WHICH ARE
ABANDONED SHALL BE TRIMMED TO FLOOR SURFACE, GROUND FLUSH AND
FILLED WITH GROUT, AND FINISHED TO MATCH ADJACENT FLOOR SURFACE.
GENERAL NOTES
NO CEILING
W ORK
A002
A002
C2
C2
V4
V4V4
L1E
L1E
MENS
RESTROOM
WOMENS
RESTROOM
8 8
MENS
RESTROOM
WOMENS
RESTROOM
NO CEILING
W ORK
A002
A002
9 7
MENS
RESTROOM
WOMENS
RESTROOM
NORTH WOMENS RESTROOM NORTH MENS RESTROOM SOUTH MENS RESTROOM SOUTH W OMENS RESTROOM
SHOWER
ROOM - DEMO
SHOWER
ROOM - DEMO
REVISIONS
6/19/2025 1:43:47 PM
RESTROOM
ELECTRICAL PLANS
E002 | Project# PROJECT# | L:\
06/16/2025
© 2025 | ALL RIGHTS RESERVED
100% CONSTRUCTION
DOCUMENTS
P L
U M
B
IN
G S
E R
V
IC
E S
R E
P A
IR
U S
D A
A P
H
IS
P P
Q P
H O
E N
IX
R
E A
R
IN
G F
A C
IL
IT
Y
A P
H
IS
-M N
-1
E A
S T
C H
IP
M
A N
R D
P
H O
E N
IX
A R
IZ
O
N A
PROJ# | PROJECT#
DESIGNED BY | GROSS
DRAWN BY | GROSS
REVIEWED BY | VICTORINO
1/4" = 1'-0"E002
1 ENLARGED NORTH RESTROOM - POW ER PLAN
1/4" = 1'-0"E002
3 ENLARGED SOUTH RESTROOM - POW ER PLAN
1/4" = 1'-0"E002
4 SOUTH RESTROOM - LIGHTING PLAN
# KEYNOTES
1 CONNECT LIGHTING IN THIS AREA TO EXISTING CIRCUIT MADE AVAILABLE BY
DEMOLITION. CIRCUIT SHOWN BASED ON AS-BUILT DRAWINGS. FIELD
COORDINATE CIRCUIT NUMBER AND UPDATE PANEL SCHEDULE AS REQUIRED.
CONNECT TO CONTROLS AS DIRECTED BY EQUIPMENT MANUFACTER.
2 MAINTAIN AND PROTECT EXISTING RECEPTACLE AND ASSOCIATED CONNECTION
AT THIS LOCATION. CIRCUIT SHOWN BASED ON AS BUILT DRAWINGS.
CONTRACTOR TO VERIFY CIRCUIT AND UPDATE PANEL DIRECTORY AS
REQUIRED.
3 REFER TO SHEET A000 FOR PANEL LOCATION.
4 CONNECT OCCUPANCY SENSOR AS REQUIRED TO OVERRIDE MANUAL
CONTROLS. COORDINATE WITH EQUIPMENT MANUFACTURER WIRING DIAGRAMS.
5 CONNECT EXISTING SWITCH TO NEW LIGHTS VIA OCCUPANCY SENSOR.
6 REMOVE EXISTING LIGHTING AS SHOWN. CIRCUIT TO REMAIN IN VICINITY FOR
REUSE.
7 ALL EXISTING SWITCHES ARE TO REMAIN, UNLESS OTHERWISE NOTES. PROTECT
IN PLACE DURING CONSTRUCTION. SEE IMAGES ON THIS SHEET FOR
ADDITIONAL INFORMATION.
8 REMOVE EXISTING SWITCH AND ASSOCIATED CONNECTION AS REQUIRED FOR
WALL DEMOLITION
9 REMOVE EXISTING SWITCH. CONNECTION TO REMAIN FOR REUSE, REFER TO
2/E002.
10 INSTALL WALL MOUNTED OCCUPANCY SENSOR AT EXISTING LIGHT SWITCH
LOCATION AND CONNECT USING EXISTING CONNECTIONS AS REQUIRED TO
PROVIDE AUTOMATIC CONTROL.
11 EXISTING DRINKING FOUNTAIN OUTLET TO BE REPLACED WITH GFI DEVICE AND
RECONNECTED TO EXISTING CIRCUIT. COORDINATE LOCATION OF EXISTING
DEVICE WITH MANUFACTURER INSTALLATION INSTRUCTIONS AND RELOCATE
EXISTING DEVICE AS NECESSARY.
1/4" = 1'-0"E002
2 NORTH RESTROOM - LIGHTING PLAN
1/4" = 1'-0"E002
6 SOUTH RESTROOM - LIGHTING PLAN DEMO
1/4" = 1'-0"E002
5 NORTH RESTROOM - LIGHTING PLAN DEMO
1" = 1'-0"E002
7 EXISTING LIGHT SW ITCHES
NORTH REF NORTH REF NORTH REF
NORTH REF NORTH REF NORTH REF
06/19/2025
| Sheets |
| E001 - ELECTRICAL LEGENDS |
| E002 - RESTROOM ELECTRICAL PLANS |
File details come from the government source that posted it. Updated .