BRKR212008 Type B3 Drawings SIGNED.pdf
PDF 17 MB Posted
- Attached to
- Renovate Building 410 Federal contract opportunity
- Solicitation number
- W50S6M-24-B-0001
About this file
This document provides details for a federal contract opportunity to renovate Building 410. The 117th Air Refueling Wing of the Alabama Army National Guard is soliciting bids for a firm fixed-price contract to conduct interior demolition and renovation at an existing building, including relocating HVAC equipment and electrical systems, as well as underground utility work. The project scope includes demolition, construction, and relocation of walls, ceilings, floors, building systems, generators, and utility infrastructure. The total project value is estimated between $500,000 and $1,000,000. The NAICS code is 236220 for commercial and institutional building construction. The small business size standard is $45,000,000. This opportunity is 100% set aside for small businesses. The award will be made to the responsible bidder with the most advantageous price according to the terms of the invitation for bids.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| OF-1419 signed.pdf | ||
| BRKR 212008 RFI Responses 002.pdf | ||
| BRKR212008 - ADDENDUM NO 2 SIGNED.pdf | ||
| BRKR 212008 RFI Responses 001.pdf | ||
| SF-30 Amendment Document.pdf | ||
| Site visit attendees.pdf | ||
| PreBid bldg 410.pptx | PPTX presentation | |
| J and A for Brand Name-Sole Source - bldg 410- Stanley Best Locks SV_Redacted.pdf | ||
| BRKR212008 Type B3 Specifications 01-25-24 SIGNED.pdf | ||
| W50S6M-24-B-0001.pdf | ||
| J and A for Brand Name-Sole Source - Bdlg 410 - Advantor.pdf | ||
| J and A for Brand Name-Sole Source - bldg 410- Monaco Fire Alarm_Redacted.pdf | ||
| J and A for Brand Name-Sole Source - bldg 410- Kreiger Door.pdf | ||
| BRKR212008 - ADDENDUM NO 1 SIGNED.pdf | ||
| SF-30 Amendment 0001.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T1.0
TITLE SHEET
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
DRAWING INDEX
SHEET NO. SHEET NAME
07 MECHANICAL
M0.1 GENERAL MECHANICAL NOTES, LEGEND, AND ABBREVIATIONS
M1.1 MECHANICAL DEMOLITION PLAN
M2.1 MECHANICAL NEW WORK PLAN AND SECTIONS
M5.1 MECHANICAL DETAILS
M5.2 MECHANICAL DETAILS
M6.1 MECHANICAL SCHEDULES
M7.1 MECHANICAL CONTROLS
08 MASS NOTIFICATION
MN1.1 MASS NOTIFICATION PLAN
09 ELECTRICAL
E0.1 ELECTRICAL LEGEND & NOTES
E0.2 ELECTRICAL LEGEND & NOTES
E1.1 ELECTRICAL RISER & NOTES
E1.2 ELECTRICAL GROUNDING DETAILS
E1.3 ELECTRICAL - GROUNDING DETAILS
E2.1 ELECTRICAL - LUMINAIRE SCHEDULE & DETAILS
E2.2 ELECTRICAL - LIGHTING DETAILS
E2.3 ELECTRICAL - PANEL SCHEDULES & DETAILS
E2.4 ELECTRICAL - EQUIPMENT SCHEDULES
E3.1 ELECTRICAL - SITE PLAN
E4.0 ELECTRICAL - FLOOR PLAN - DEMOLITION
E4.1 ELECTRICAL - FLOOR PLAN - LIGHTING
E5.1 ELECTRICAL - FLOOR PLAN - POWER
E5.2 ELECTRICAL - FLOOR PLAN - EQUIPMENT POWER
E6.1 ELECTRICAL - FLOOR PLAN - AUXILIARY
E6.2 ELECTRICAL - SECURITY AND ACCESS CONTROLS
E6.3 ELECTRICAL - COMMUNICATION DETAILS
E6.4 ELECTRICAL - COMMUNICATION DETAILS
DRAWING INDEX
SHEET NO. SHEET NAME
00 TITLE
T1.0 TITLE SHEET
T2.0 GENERAL WORK NOTES, ABBREVIATIONS & SYMBOLS
T3.0 TYPICAL MOUNTING HEIGHTS & CLEARANCES
01 LIFE SAFETY
LS1.0 LIFE SAFETY
03 CIVIL
C1.1 SITE PLAN
C2.1 SITE DETAILS
04 ARCHITECTURAL
A1.0 DEMOLITION NOTES
A2.1 FLOOR PLANS
A3.1 FINISH SCHEDULES
A3.2 DOOR SCHEDULE, SECTION, & DETAILS
A6.1 ENLARGED FLOOR PLANS
05 FIRE PROTECTION
FD1.1 FIRE PROTECTION DEMOLITION PLAN
06 PLUMBING
P1.1 PLUMBING PLAN - WASTE AND WATER
P6.1 SCHEDULES, LEGEND, AND RISER DIAGRAM
RENOVATE BUILDING 410
Sumpter Smith Joint National Guard Base
BRKR 212008
Birmingham IAP (ANG), AL
Architect:
Design Team: Consulting Engineers:
Approvals:
Title: Signature: Date:
Base Commander
Base Civil Engineer
Base Project Engineer
Bio Environmental Eng.
Safety
Security Police
Base Communications
Fire Chief
Using Agent
Mechanical:
Electrical: Civil:
Rev. Description Date
202A
A101
1Ref
Re f
1 Ref
Re f
A101
Ref
1Re f
1 Re f
Ref
ROOM NAME
150 SF
1t
1i
A101
SIM
A101
SIM
A101
SIM
Building Elevation Tag
Interior Elevation Tag
Building Section Tag
Wall Section Tag
Detail Tag
General Symbol Legend
Room Tag
ADA Approved Turning Space
Spot Elevation
Door Tag (See Door Schedule)
Window Tag (See Window Schedule)
Wall/Storefront Tag (See Wall/Storefront Schedule)
Revision Tag (See Revision Schedule)
X Specific Note Tag
Electric Water Cooler (See Plumbing)
Fire Extinguisher Cabinet
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T2.0
GENERAL WORK
NOTES,
ABBREVIATIONS &
SYMBOLS
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
General Project Notes:
GENERAL NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES APPLY TO ISOLATED
WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL
ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT
SPECIFICALLY NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL
DEMOLITION NOTES OR A SPECIFIC WORK NOTE(S) USED IN OTHER SIMILAR
CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL OF THE GOVERNMENT.
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY CONDITIONS
1. CONTRACTOR TO VISIT SITE AND TO BECOME TOTALLY FAMILIAR WITH EXTENT OF
WORK REQUIRED PRIOR TO BID.
2. CONTRACTOR TO VERIFY DIMENSIONS OF INTERIOR PARTITION WALLS. IF
DISCREPANCY OCCURS, NOTIFY THE GOVERNMENT PRIOR TO FRAMING.
3. CONTRACTOR TO VERIFY ALL FINISHED DIMENSIONS BEFORE INSTALLATION OF
CABINET WORK AND TRIMWORK.
4. DIMENSIONS OF EXISTING STRUCTURES ARE ONLY FOR THE CONVENIENCE OF THE
CONTRACTOR, VERIFY ALL EXISTING CONDITIONS. LOCATION OF WALLS SHALL BE
AS SHOWN ON PLAN RELATIVE TO EXISTING CONDITIONS.
5. CONTRACTOR TO VERIFY ALL DIMENSIONS AND FIELD CONDITIONS WITH THE
DRAWINGS, IN PARTICULAR: WALL DIMENSIONS, INCOMING UTILITIES, ETC. REPORT
IMMEDIATELY TO THE GOVERNMENT ANY VARIANCES OR FIELD CONDITIONS THAT
MAY CAUSE CONSTRUCTION PROBLEMS PRIOR TO COMMENCING WORK.
CONTRACTOR'S REPONSIBILITY TO COORDINATE THE WORK
1. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO COMMENCING.
FURNISH INFORMATION NECESSARY TO ADJUST, MOVE OR RELOCATE EXISTING
STRUCTURES, UTILITY POLES, LINES, SERVICES OF OTHER SYSTEMS LOCATED IN,
OR AFFECTED BY CONSTRUCTION. COORDINATE WITH LOCAL AUTHORITIES
HAVING JURISDICTION WITH CONSTRUCTION.
2. CONTRACTOR TO VERIFY APPLICABLE OPENINGS, DOOR SIZES, AND DIMENSIONS
OF MECHANICAL ROOMS WITH EQUIPMENT. IF DISCREPANCY OCCURS, NOTIFY
THE GOVERNMENT PRIOR TO FRAMING.
3. CONTRACTOR TO COORDINATE PLUMBING AND MECHANICAL LINES WITH CEILING
HEIGHTS, ABOVE CEILING AREAS AND STRUCTURAL ELEMENTS.
4. CONTRACTOR TO VERIFY WITH STRUCTURAL, PLUMBING, MECHANICAL, AND
ELECTRICAL THE QUANTITY AND SIZES OF ALL SLEEVES REQUIRED. ALL SLEEVES
TO BE ONE HOUR RATED, PROVIDE GREATER RATING IF PENETRATING INTO HIGHER
RATED SPACE.
5. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT THE HEAD HEIGHT IS
NOT ENCUMBERED AND SERVICES ARE AS TIGHT UP TO STRUCTURE AS POSSIBLE.
6. CONTRACTOR TO COORDINATE PLUMBING, MECHANICAL, FIRE SPRINKLER,
ELECTRICAL, AND LIGHTING WITH STRUCTURAL ELEMENTS WHERE THERE IS
EXPOSED STRUCTURE. CONDUIT LINES, ECT. SHALL RUN AT RIGHT ANGLES OR
SEGMENTED BETWEEN COLUMN LINES AND BE CLEAN AND NEAT IN APPEARANCE.
7. COORDINATE LOCATION OF SWITCHES, OUTLETS, THERMOSTATS, LIGHTS, ETC. W/
SHELVING, TRIM, MARKER BOARDS, AND CABINETRY. MOVE AS REQUIRED TO
MISS SHELVING, STORAGE, CASEWORK, VISUAL DISPLAY BOARDS.
8. COORDINATE CONDUIT, PIPING, AND DUCTWORK SO THAT HEAD HEIGHT IS NOT
ENCUMBERED AND SERVICES ARE AS TIGHT UP TO STRUCTURE AS POSSIBLE,
THIS WILL INCLUDE JOGGING DUCTS, SPRINKLER LINES, PLUMBING LINES,
CONDUIT, ECT. UP AND DOWN OR AROUND AS REQUIRED TO ACHIEVE CEILING
HEIGHTS AS INDICATED. COORDINATE INSTALLATION AND SEQUENCING OF
DISCIPLINES TO ACHIEVE.
9. THE GENERAL CONTRACTOR SHALL STAKE OUT ALL MAJOR FEATURES SHOWN ON
THE SITE PLAN TO VERIFY THE SITE LAYOUT RELATIVE TO THE PROPERTY LINES AND
SITE CONDITIONS PRIOR TO ANY UTILITIES OR FOOTINGS BEING INSTALLED.
10. PLUMBING, FIRE-PROTECTION, MECHANICAL, AND ELECTRICAL WORK REQUIRED BY
THIS CONTRACT IS NOTED ON CONTRACT DOCUMENTS. THE TRADE
CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK
WITH ALL TRADES. CHANGE ORDERS SHALL NOT BE APPROVED FOR EXTRA WORK
ARISING FROM TRADE CONTRACTORS NOT COORDINATING WORK.
11. CONTRACTOR WILL BE RESPONSIBLE FOR ALL LAYOUT FOR INTERIOR/EXTERIOR
WALLS AND FOUNDATION AND WILL BE RESPONSIBLE FOR MAINTAINING A
BENCHMARK AND CONTROL LINES AT EACH FLOOR LEVEL. CONTRACTOR IS ALSO
RESPONSIBLE FOR VERIFYING ACTUAL FLOOR HEIGHTS AND COORDINATING NEW
AND EXISTING FLOORS TO ALIGN.
12. EACH TRADE CONTRACTOR WILL BE RESPONSIBLE FOR FURNISHING AND
INSTALLING CEILING OR WALL-MOUNTED ACCESS DOORS AS REQUIRED TO
ACCESS COMPONENTS OF ITS SYSTEM AND TO COORDINATE WITH OTHER
TRADES SO ACCESS IS MAINTAINED
13. CONTRACTOR SHALL COORDINATE TO ASSURE ALL EQUIPMENT CAN BE BROUGHT
INTO THE BUILDING. THIS INCLUDES MANUFACTURE COMPONENT SIZE/ASSEMBLY,
CRITICAL PATH SCHEDULING, AND COORDINATION OF OTHER TRADES.
ACT Acoustical Ceiling Tile A/C Air Conditioning AB Anchor Bolt ADA American Disabilities Act AFF Above Finish Floor BM Beam BRG Bearing BRK Brick CFCI Contractor Furnished
Contractor Installed CIP Cast In Place CJ Control Joint CL Column Line CLG Ceiling CLR Clear CMU Concrete Masonry Unit COL Column CONC Concrete CONT Continuous CONTR Contractor COORDF Coordination CORR Corridor CT Ceramic Tile CTR Center DBL Double DET Detail DIA Diameter DR Drain DN Down DS Downspout DW Dishwasher DWG Drawing DWR Drawer EA Each EF Exhaust Fan EJ Expansion Joint EL Elevation ELEC Electrical EQ Equal EX Existing EXT Exterior FF Finish Floor FIN Finish FL Floor Line FlSNG Flashing FTG Footing GA Gauge GFRC Glass Fiber Reinforced
Concrete
GWB GWB
HT Height HM Hollow Metal HOR Horizontal HR Handrail HTR Heater HVAC Heating, Ventilation & Air
Conditioning HxWxL Height, width, length IN Inches INSUL Insulation INT Interior JST Joist
JT Joint LAM Laminate LAV Lavatory LVR Louver MIN Minimum MAX Maximum MECH Mechanical MET Metal MFR Manufacturer MH Man Hole MIN Minimum MISC Miscellaneous MLDG Moulding MO Masonry Opening MTD Mounted MW Microwave NIC Not In Contract NO Number NOM Nominal NTS Not to Scale OC On Center OFCI Owner Furnished
Contractor Installed OFOI Owner Furnished
Owner Installed OPP Opposite P Paint PL Plate / Property Line PL LAM Plastic Laminate PLYWD Plywood PNL Panel PT Pressure Treated R Radius / Riser RB Rubber Base REFR Refrigerator REINF Reinforce (D) REV Revised RM Room SCHED Schedule SECT Section SHT Sheet SHW Single Hung Window SIM Similar SPECS Specifications SQ Square SS Sanitary Sewer STD Standard SVT Solid Vinyl Tile STL Steel T Tile T&G Tongue & Groove TYP Typical UNO Unless Noted
Otherwise VERT Vertical VTR Vent Thru Roof VWC Vinyl Wall Covering WD Wood WWM Welded Wire Mesh WWF Welded Wire Fabric YP Yellow Pine
Typical Abbreviation Legend:General Project Notes (Continued):
CONTRACTOR'S RESPONSIBILTY TO COMPLY WITH APPLICABLE GOVERNING
CODES/AUTHORITIES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, LAWS,
AND ORDINANCES. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR
OBTAINING ALL PERMITS, INSPECTIONS, AND CERTIFICATES REQUIRED BY
GOVERNING ENTITIES.
2. CONTRACTOR TO CONFIRM ALL OSHA AND APPLICABLE STANDARDS TO
ASSURE SAFETY OF ALL PERSONS ON SITE DURING ENTIRE COURSE OF
CONSTRUCTION.
3. NEITHER THE ARCHITECT, NOR THE GOVERNMENT SHALL BE RESPONSIBLE
FOR JOB SAFETY. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR
JOB SITE SAFETY AND SAFETY OF THE PUBLIC DURING CONSTRUCTION AND
SHALL PROVIDE APPROPRIATE WARNINGS, BARRICADES, ETC. AS REQUIRED
PER CODES.
4. PROMPTLY NOTIFY THE GOVERNMENT IN WRITING IF ANY CONTRACT
DOCUMENTS ARE FOUND TO BE IN VARIANCE WITH THE APPLICABLE LAWS
AND ORDINANCES. NECESSARY CHANGES WILL BE MADE BY APPROPRIATE
MODIFICATIONS.
5. IF ANY WORK IS PERFORMED KNOWING IT TO BE CONTRARY TO SUCH CODES,
LAWS, ORDINANCES, RULES AND REGULATIONS, AND WITHOUT NOTICE TO
THE GOVERNMENT, THAT TRADE CONTRACTOR ASSUMES FULL
RESPONSIBILITY AND BEARS COSTS ATTRIBUTED TO BRING WORK TO
COMPLIANCE OF SUCH CODES, LAWS, ORDINANCES, AND RULES AND
REGULATIONS.
GENERAL PROVISIONS FOR FIRE RATED CONSTRUCTION
1. ALL RECESSED ACCESSORIES LOCATED IN FIRE RATED WALLS SHALL BE
EITHER OF FIRE RATED CONSTRUCTION OR COORDINATED WITH THE
ADJACENT TRADES TO ALLOW THE GYPSUM BOARD TO BE CONTINUOUS
BEHIND THE ACCESSORIES.
2. EACH RESPONSIBLE CONTRACTOR SHALL SEAL ALL PENETRATIONS MADE AS
PART OF THEIR WORK IN FIRE OR SOUND-RATED CONSTRUCTION AS
REQUIRED BY ALL APPLICABLE CODES. EACH CONTRACTOR TO VERIFY WITH
LOCAL FIRE MARSHAL OR BUILDING OFFICIAL HAVING JURISDICTION. EACH
RESPONSIBLE CONTRACTOR WILL SEAL ALL PENETRATIONS MADE AS PART OF
THEIR WORK THROUGH NON-RATED PARTITIONS. ALL FIRE CAULK TO BE THE
SAME BRAND AS DETERMINED BY CONTRACTOR.
3. ALL NEW AND EXISTING FIRE OR SOUND WALLS IN WORK AREAS ARE TO BE
CARRIED TO THE UNDERSIDE OF THE ROOF DECK AND SEALED AS REQUIRED
FOR NECESSARY RATINGS, AND LABELED PER THE AUTHORITY HAVING
JURISDICTION.
4. MATERIALS WITHIN PLENUMS. EXCEPT AS REQUIRED BY THE 2009
INTERNATIONAL MECHANICAL CODE SECTION 602.2.1.1 THROUGH
602.2.1.6, MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR
SHALL HAVE A FLAME SPEAD INDEX OF NOT MORE THAN 25 AND A SMOKE-
DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE
WITH ASTM E84 OR UL 723.
MISCELLANEOUS GENERAL PROVISIONS:
1. CONTRACTOR TO NOTIFY THE GOVERNMENT IMMEDIATELY IF THERE ARE ANY
DISCREPANCIES WITH TAGGED DETAILS, ENLARGED PLANS, ELEVATIONS, ETC.
2. IN ROOMS WITH FLOOR DRAINS, SLOPE TO DRAIN AT 1 PERCENT SLOPE
UNLESS SPECIFICALLY NOTED OTHERWISE.
M A X
" M
A X
" M
IN
PAPER TOWEL
DISPENSER
MIRROR
SOAP
DISPENSER
ROBE
HOOK
TO
T
O P
O F
H O
O K
" T
YP
LAVATORY. PROVIDE ADA
INSULATION KIT WHEN REQUIRED
URINAL
42" MIN
MAX
1' - 0"
" M
IN
" M
IN
" M
IN
" M
IN
WATER
CLOSET
TOILET
PAPER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
HORIZONTAL
GRAB BAR
VERTICAL GRAB BAR
MIN
1' - 3"
39 MIN - 41 MAX
ALLOWABLE
MOUNTING
AREA
TO
B
O
TT
O M
O F
RE
FL
EC
TI
V E
S U
RF
AC
E
" M A X
H A
FF
M
IN
M A X
16" - 18"
M
IN
M
AX
12 MIN
36 MIN.
HORIZONTAL
GRAB BAR
TYPICAL ADA MOUNTING HEIGHTS (UNLESS OTHERWISE NOTED)
" M A X
A D
A M
AX
" M
AX
FIRE
EXTINGUISHER
CABINET
ADA ELECTRIC
WATER COOLER
H A
FF
" M
IN
" M
A X.
M
IN
" M
IN
MIN.
8"
" M
AX
6" MAX.
11" MIN
CL
5" MAX. 15" MIN.
MIN. CLEAR DEPTH
48"
M
IN
C
LE
AR
W
ID
TH
ADA ELECTRIC
FOUNTAIN SKIRT
SHERE LOCATED IN
CIRCULATION PATH
" M
IN
18" MIN
(A)
FRONT APPROACH, PULL SIDE
" M
IN
(B)
FRONT APPROACH, PUSH
SIDE
" M
IN12" MIN
(C)
FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
36" MIN
" M
IN
(D)
HINGE APPROACH, PULL SIDE
42" MIN
" M
IN
(E)
HINGE APPROACH, PULL SIDE
" M
IN
22" MIN
(F)
HINGE APPROACH, PUSH SIDE
(G)
HINGE APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND
LATCH
" M
IN
22" MIN
24" MIN
" M
IN
(H)
LATCH APPROACH, PULL SIDE
(I)
LATCH APPROACH, PULL SIDE,
DOOR PROVIDED WITH CLOSER
" M
IN 24" MIN
24" MIN
" M
IN
(J)
LATCH APPROACH, PUSH SIDE
(K)
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
24" MIN
" M
IN
" M
IN12" MIN
(C)
PUSH SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
X > 8"4
" M
IN
(B)
PUSH SIDE
" M
IN
18" MIN
X > 8"
(A)
PULL SIDE
24" MIN
" M
IN
(D)
STOP OR LATCH APPROACH
22 MIN
m in
(C)
POCKET OR HINGE APPROACH
(B)
SIDE APPROACH
M
IN
m in
(A)
FRONT APPROACH
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
T3.0
TYPICAL
MOUNTING
HEIGHTS &
CLEARANCES
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
1. ADA STANDARDS FOR ACCESSIBLE DESIGN AND ICC/ANSI A117.1 ARE
THE REFERENCE STANDARDS USED FOR SCOOPING PROVISIONS FOR
ACCESSIBILITY. THE MORE STRINGENT PROVISIONS OF THE TWO
STANDARDS ARE INDICATED.
2. DIAGRAMS SHOWN ARE FOR MOUNTING HEIGHT INFORMATION ONLY.
FIXTURES SHOWN ARE NOT NECESSARILY INCLUDED IN THE PROJECT.
3. COORDINATE ADA REQUIREMENTS WITH ALL REQUIRED CONCEALED
WOOD BLOCKING.
4. REFER TO MANUFACTURER'S LITERATURE REGARDING RECOMMENDATIONS
FOR MOUNTING PRODUCTS AND MATERIALS IN COMPLIANCE WITH ADA
STANDARDS.
GENERAL NOTES:
3/8" = 1'-0"T3.0
5 ADA DOOR OPENING MANEUVERING CLEARANCES
1235 SF
B-CONCENTRATED
FE
C
EW
C
301 SF
B-MECH
365 SF
B-GENERAL
172 SF
B-CONFERENCE
81 SF
B-IT
FEB
HANDICAP ACCESSIBLE EXIT LOCATION
FIRE EXTINGUISHER CABINET (2A:10B:C)FEC
ELECTRIC WATER COOLER - SEE PLUMBINGEWC
SAPF PERIMETER MEETING ICD 705, STC 50
EMERGENCY EXIT SIGNAGE
IBC GROUP B (BUSINESS)
15 NET SF PER OCCUPANT PER UFC 3-600-01
ORDINARY HAZARD PER NFPA 101
SYMBOLS LEGEND
ROOM TAG
ROOM NAME
150 SF
EGRESS CALCULATION LEGEND:
IBC GROUP B (BUSINESS)
50 NET SF PER OCCUPANT PER NFPA 101
ORDINARY HAZARD PER NFPA 101
IBC GROUP B (BUSINESS)
150 NET SF PER OCCUPANT PER NFPA 101
ORDINARY HAZARD PER NFPA 101
IBC GROUP B (BUSINESS)
300 NET SF PER OCCUPANT PER UFC 3-600-01
ORDINARY HAZARD PER NFPA 101
IBC GROUP B (BUSINESS)
500 NET SF PER OCCUPANT PER UFC 3-600-01
ORDINARY HAZARD PER NFPA 101
FIRE EXTINGUISHER BRACKET (2A:10B:C)
FEB
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
LS1.0
LIFE SAFETY
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
APPLICABLE CODES:
BUILDING CODE..............UFC 1-200-01 / 2018 INTERNATIONAL BUILDING CODE
STRUCTURAL CODE...........UFC 3-301-01
PLUMBING CODE............UFC 3-420-01
MECHANICAL CODE.........UFC 3-401-01
FIRE CODE..................UFC 3-600-01 / NFPA 101
ELECTRICAL CODE...........UFC 3-501-01
ENERGY CODE..............UFC 1-200-02
ACCESSIBILITY CODE......2010 ADA STANDARDS
LIFE SAFETY CODE........UFC 3-600-01/NFPA 101
IBC CHAPTER 3 AND UFC 3-600-01 OCCUPANCY & USE:
NFPA 101 CHAPTER 6:
• SEE LEGEND ON LIFE SAFETY PLAN
IBC CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS:
• NOT APPLICABLE
IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS & AREAS:
• CONSTRUCTION TYPE = II-B, NON-SPRINKLED, GROUP B NON-SEPARATED
• ALLOWABLE BUILDING HEIGHT (PER TABLE 504.3)
55 FEET ABOVE GRADE PLANE
• ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (PER TABLE 504.4)
3 STORIES ABOVE GRADE PLANE
• ALLOWABLE TABULAR BUILDING AREA (PER TABLE 506.2)
23,000 SQUARE FEET
• FIRE SEPARATION REQUIREMENTS NONSEPARATED OCCUPANCIES
PROTECTION FROM HAZARDS PER NFPA 101 38.3.2
NO PROTECTION FROM HAZARDS REQUIRED
IBC CHAPTER 6 TYPES OF CONSTRUCTION:
• CONSTRUCTION TYPE: II-B
• FIRE RATINGS (PER TABLE 601) AS FOLLOWS (EXCEPT WHERE NOTED OTHERWISE)
PRIMARY STRUCTURAL FRAME.............................. 0 HOUR
BEARING WALLS (INTERIOR & EXTERIOR)...................0 HOUR
NON-BEARING WALLS AND PARITIONS (INTERIOR)........0 HOUR
FLOOR CONSTRUCTION AND SECONDARY MEMBERS...0 HOUR
ROOF CONSTRUCTION AND SECONDARY MEMBERS....0 HOUR
• REQUIRED FIRE RATING (PER TABLE 602)
OCCUPANCY FIRE SEPARATION REQ.
TYPE (ACTUAL) SEPARATION
B 30'-0" 0 HR
IBC CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES:
• FIRE WALLS (PER NFPA 8.3.2)
NO FIRE WALLS ARE PRESENT WITHIN THE SCOPE OF THE PROJECT
IBC CHAPTER 8, UFC 3-600-01, NFPA 101 - INTERIOR FINISHES:
• FINISH MATERIAL RATING REQUIREMENTS (PER NFPA 101)
BUSINESS (CHAPTER 38)
EXITS AND EXIT ACCESS CORRIDORS
INTERIOR FLOOR FINISH - NOT LESS THAN CLASS I OR II (38.3.3.1)
UFC 3-600-01(REPLACES IBC CHAPTER 9) - FIRE PROTECTION SYSTEMS:
• SECTION 9-1 - EMERGENCY VEHICLE ACCESS
1. FACILITY DOES NOT REQUIRES ONE MEANS OF ALL-WEATHER EMERGENCY
VEHICLE GROUND ACCESS IN ACCORDANCE WITH 9-1.1
2. FACILITY DOES NOT REQUIRE AERIAL APPARATUS ACCESS IN ACCORDANCE
WITH 9-1.2
NFPA CHAPTER 7 (REPLACES IBC CHAPTER 10) - MEANS OF EGRESS:
• OCCUPANCY LOAD (PER TABLE 7.3.1.2):
SEE OCCUPANCY TABLE
• EGRESS CAPACITY SIZING (PER TABLE 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
SEE LIFE SAFETY PLAN FOR INDIVIDUAL ROOM EGRESS ANALYSIS
• MINIMUM STAIR WIDTH (PER SECTION 7.3.3.1)
SEE CODE CALCULATIONS TABLE(S)
• NUMBER OF MEANS OF EGRESS (PER SECTION 7.4.1)
TOTAL NUMBER OF EXITS REQUIRED
NEW BUSINESS OCCUPANCY (CHAPTER 38)
GROUND FLOOR - 1 EXIT REQUIRED
• COMMON PATH OF EGRESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 38)
75 FT PER 38.2.5.3.3
• EXIT ACCESS TRAVEL DISTANCE
BUSINESS OCCUPANCY (CHAPTER 38)
200 FEET PER 38.2.6.2
FIRST FLOOR PLAN CODE CALCULATIONS
Name
Occupancy Calculations Egress Width Calculations
Area (SF) Occupancy Factor (SF per Occupant)
Total Occupant Load (Occupants)
Other Egress Component Width
Calculated Width (Other Egress Components)
(Inches)
B-CONCENTRATED 1235 SF 50 SF 25.00 0.2 5.00
B-CONFERENCE 172 SF 15 SF 12.00 0.2 2.40
B-GENERAL 365 SF 150 SF 3.00 0.2 0.60
B-IT 81 SF 300 SF 1.00 0.2 0.20
B-MECH 301 SF 500 SF 1.00 0.2 0.20
Plumbing Fixture Calculations
Name Male
Occupancy Female
Occupancy
Plumbing fixture Calculations
Drinking Fountains Req.
Water Closets Required Lavatories Required Men Women Men Women
B-GENERAL 10 5 0.5 0.25 0.5 0.25 0.2
1/8" = 1'-0"LS1.0
1 LIFE SAFETY PLAN
PLUMBING FIXTURES HAVE BEEN CALCULATED BASED UPON
UFC-3-420.01 USING THE MAXIMUM UTA OCCUPANCY RATE OF 15 IN
ACCORDANCE WITH ANGETL 15.01-00
CODE SUMMARY
TOTAL OCCUPANT LOAD = 42 OCCUPANTS
Rev. Description Date
SECTION 9-18 FIRE ALARM SYSTEMS
I. PER 9-18.1, A FIRE ALARM SYSTEM IS NOT REQUIRED.
• SECTION 9-5 - FIRE PUMPS
1. A FIRE PUMP IS NOT REQUIRED TO MEET FIRE PROTECTION DEMAND
• SECTION 9-7 - AUTOMATIC SPRINKLER SYSTEMS
1. PER 9-7.2.1, AN AUTOMATIC SPRINKLER SYSTEM IS NOT REQUIRED
• SECTION 9-10 - STANDPIPE SYSTEMS
1. PER 9-10, A STANDPIPE SYSTEM IS NOT REQUIRED
• SECTION 9-17 - PORTABLE FIRE EXTINGUISHERS
1. FIRE EXTINGUISHERS ARE PROVIDED, SEE PLANS FOR LOCATIONS
3. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.1.
A. THERE IS TWO EXISTING HYDRANTS IN THE PROXIMITY OF THE
BUILDING TO ALLOW THE FIRE FLOW TO BE MET WITHOUT EXCEEDING
1,250GPM PER HYDRANT.
SECTION 9-2 FIRE FLOW
THE CALCULATED FIRE FLOW FOR THE FACILITY IS 1,500GPM @ 20PSI FOR
2 HOURS PER NFPA 1.
• SECTION 9-3 - SERVICE MAINS AND LATERALS
1. FIRE HYDRANTS ARE PROVIDED IN ACCORDANCE WITH 9-3.5.8.2
A. ALL PARTS OF THE FACILITY EXTERIOR ARE WITHINT 350 FT OF A
HYDRANT
2. FIRE HYDRANTS IN ACCORDANCE WITH 9-3.5.8.4 - NOT APPLICABLE
3. FIRE DEPARTMENT ACCESS COMPLIES WITH NFPA 1.
DEAD ENDS
BUSINESS (CHAPTER 38)
20 FEET PER 38.2.5.3.2
3-600-0
13' - 2" 10' - 7"
11' - 11 1/4"
2' - 10" 16' - 0" 30' - 0" 32' - 4" 16' - 0" 2' - 10"
100' - 0"
3' - 0"6' - 0"
2 2 21 1 8
3 38
2 2 2 21 1 1 8
3 3
LEGEND:
EXISTING TO BE DEMOLISHED, SHORE AS REQUIRED.
EXISTING TO REMAIN
DOTTED LINE GENERALLY INDICATES EXISTING AREAS TO BE REMOVED, INCLUDING BUT
NOT LIMITED TO WALLS, DOORS, FLOOR COVERING, CEILINGS, ETC... IN CASE OF
UNCERTAINTY PROVIDE WRITTEN REQUEST TO ARCHITECT.
# SEE SPECIFIC DEMOLITION NOTE (#) NUMBER FOR WORK
TO BE DONE
# REMOVE EXISTING DOOR (SEE SPECIFIC DEMOLITION
NOTE # NUMBER FOR SPECIFIC DETAILS).
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A1.0
DEMOLITION
NOTES
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
General Demolition Notes:
THE INTENT OF DEMOLITION IS TO ACCOMPLISH ALL WORK NECESSARY TO PROVIDE A FINISHED, COMPLETE BUILDING AS INDICATED IN THE PLANS AND SPECIFICATIONS. THE FOLLOWING GENERAL NOTES ARE APPLICABLE
TO ALL DEMOLITION ACTIVITIES REQUIRED BY THE SCOPE OF THE CONTRACT DOCUMENTS.
CONTRACTOR'S RESPONSIBILTY TO VERIFY ACCURACY OF EXISTING CONDITIONS:
1. DOCUMENTATION CONTAINED IN THESE CONSTRUCTION DOCUMENTS OF EXISTING CONDITIONS MAY
NOT BE ENTIRELY ACCURATE. CONTRACTOR IS TO TAKE THE INITIATIVE TO VISIT THE SITE PRIOR TO AND
DURING THE PRE-BID MEETING TO VERIFY ACTUAL CONDITIONS, THEREFORE RENDERING THE
CONTRACTOR RESPONSIBLE FOR AN ACCURATE REPRESENTATION OF THE EXISTING CONDITIONS.
2. CONTRACTOR TO VISIT SITE TO VERIFY EXISTING CONDITIONS AND SHALL BE RESPONSIBLE FOR
DETERMINING THE SCOPE OF WORK PRIOR TO DEMOLITION . EXISTING CONDITIONS SHALL BE
THOROUGHLY RESEARCHED PRIOR TO CONSTRUCTION AND ANY DRAWINGS SHALL BE IMMEDIATELY DISCUSSED WITH THE GOVERNMENT PRIOR TO BEGINNING CONSTRUCTION IN THE AFFECTED AREA.
CHANGE ORDERS WILL NOT BE APPROVED PRIOR TO WORK TAKING PLACE FOR EXISTING CONDITIONS
READILY APPARENT BY A THOROUGH OBSERVATION.
3. CONTRACTOR TO VERIFY ALL EXISTING FLOOR ELEVATIONS AND VERIFY WITH PLANS. REPORT ANY
DISCREPANCIES WITH THE GOVERNMENT PRIOR TO CONSTRUCTION
4. DIMENSIONS OF EXISTING STRUCTURES ARE ONLY FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. LOCATION OF WALLS SHALL BE AS SHOWN ON
PLANS RELATIVE TO EXISTING CONDITIONS.
5. THE GOVERNMENT ASSUMES NO RESPONSIBILITY FOR EXISTING UNKNOWN CONDITIONS. EACH
CONTRACTOR SHALL COORDINATE NEW CONSTRUCTION WITH EXISTING CONSTRUCTION AND
INVESTIGATE IN A REASONABLE MANNER REGARDING HIDDEN CONDITIONS.
SAFEGUARDS DURING DEMOLITION:
1. CONTRACTOR TO MAKE SURE ALL INFRASTRUCTURE (POWER, GAS, WATER, CABLING, ETC...) IS TURNED
OFF AND/OR REMOVED PRIOR TO DEMOLITION.
2. CONTRACTOR TO VERIFY ALL LOAD BEARING CONDITIONS AND PROVIDE SHORING AS REQUIRED IN ALL
AFFECTED AREAS PRIOR TO & DURING DEMOLITION AND/OR CONSTRUCTION.
3. ALL CURRENT OSHA AND APPLICABLE STANDARDS SHALL BE UPHELD TO ASSURE SAFETY OF ALL
PERSONS ON SITE DURING ENTIRE COURSE OF CONSTRUCTION.
CONTRACTOR'S RESPONSIBILTY TO REMOVE ALL ENCUMBRANCES REQUIRED FOR PROPER INSTALLATION OF
NEW SYSTEMS:
1. REMOVAL OF ALL ENCUMBRANCES INCLUDING BUT NOT LIMITED TO DUCTS, PIPING, WIRING, ETC… SHALL
BE DONE BY THE CONTRACTOR TO ACHIEVE PLANS AS SHOWN EVEN IF NOT SHOWN ON DEMOLITION
PLANS.
2. REMOVAL OF ALL ENCUMBRANCES INCLUDING BUT NOT LIMITED TO CONCRETE, WOOD, DUCTS, PIPING, WIRING, SHALL BE DONE BY THE CONTRACTOR TO ACHIEVE FLOOR PLANS AS SHOWN EVEN IF NOT
SHOWN ON DEMOLITION PLANS.
3. REMOVE ALL CEILINGS AND ITEMS ABOVE CEILINGS THAT ARE NOT REQUIRED IN THE RENOVATED BUILDING AND AS REQUIRED TO INSTALL NEW HVAC, PLUMBING, LIGHTING, ELECTRICAL, ETC. FOR FULLY
FUNCTIONING SYSTEMS.
4. REMOVE ANY UNUSED PENETRATIONS AND INSTALL NEW DECKING/ROOFING OVER ANY OPENINGS
5. REMOVE ALL ABANDONED FIXTURES, PIPING, CONDUIT WIRING, INSULATION, EQUIPMENT, STRUCTURAL
SUPPORTS, ARCHITECTURAL SYSTEMS., ETC… NO LONGER IN USE OR UNNECESSARY FOR THE
RENOVATED PROJECT. PROVIDE PATCHING WITH MATERIALS CONSISTENT WITH ADJACENT MATERIALS
AND FINISHES REQUIRED, UNLESS OTHERWISE NOTED, TO MEET ALL APPLICABLE CODES.
6. REMOVE EXISTING FLOORING AS REQUIRED TO INSTALL NEW FLOORING. PROVIDE MANUFACTURE’S REQUIRED LEVELING MATERIALS PRIOR TO INSTALLING NEW FLOORS. REFER TO SPECIFICATIONS OF FLOORING FOR ADDITIONAL REQUIREMENTS. FIELD TEST EXISTING FLOORING SUBSTRATE AS REQUIRED BY PROJECT SPECIFICATIONS AND/OR FLOORING MANUFACTURER TO ENSURE MOISTURE CONTENT, RELATIVE HUMIDITY, FLOOR FLATNESS, AND OTHER SUBSTRATE CONDITIONS ARE WITHIN ACCEPTABLE RANGES FOR INSTALLATION OF NEW SCHEDULED FLOOR MATERIALS INTENDED TO BE INSTALLED.
PROVIDE MANUFACTURER'S WRITTEN ACCEPTANCE OF SUBSTRATE CONDITIONS PRIOR TO PROCEEDING WITH INSTALLATION OF NEW FLOOR SYSTEMS. INSTALLATION OF NEW FLOORING SYSTEMS INDICATED
ACCEPTANCE OF THE SUBSTRATE BY THE CONTRACTOR AND INSTALLER.
7. THE CONTRACTOR IS ALSO RESPONSIBLE FOR THE REMOVAL OF DEMOLISHED MATERIALS: FOR THE PATCHING OF EXISTING SURFACES, INCLUDING OPENINGS IN FLOORS, WALLS, ETC. TO MATCH UNDISTURBED EXISTING SURFACES, AND FOR LEAVING THE AREA IN A CLEAN CONDITION. REFER TO
CONTRACT DOCUMENTS FOR SPECIFIC FLOOR RELATED DETAILS.
General Demolition Notes (Continued):
CONTRACTOR'S RESPONSIBILTY TO RETURN THE SITE/STRUCTURE TO PRE-WORK CONDITIONS
1. CONTRACTOR TO TAKE EXTREME CARE AT EXISTING EXTERIOR FINISHES, INCLUDING BUT NOT LIMITED TO
BRICK, METALWORK, WINDOWS, AND DOORS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY
EXTERIOR FINISHES THAT WERE COMPROMISED DURING THE COURSE OF CONSTRUCTION.
2. CONTRACTOR TO PROTECT ALL FINISHES TO REMAIN ON INTERIOR OF EXISTING SPACES INCLUDING
WALLS, CEILINGS, FLOORS, DOORS, FIXTURES, ETC.
CONTRACTOR'S RESPONSIBILITY REGARDING REMOVAL AND DISPONSAL OF DEMOLISHED MATERIALS:
1. EACH TRADE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LAWS, REGULATIONS, AND/OR ORDINANCES REGARDING THE METHOD OF DEMOLITION AND DISPOSAL OF WASTE MATERIALS.
THE GOVERNMENT ASSUMES NO LIABILITY FOR EXTRA WORK OR ADDITIONAL COMPENSATION DUE TO FAILURE OF THE TRADE CONTRACTOR OR SUBCONTRACTORS TO COMPLY WITH ANY AND ALL SUCH
REGULATIONS THAT APPLY.
ADDITIONAL MISCELLANEOUS PROVISIONS
1. GENERAL DEMOLITION NOTES APPLY TO THE ENTIRE PROJECT. SPECIFIC NOTES (DESIGNATED) APPLY TO
ISOLATED WORK AREAS AND ARE FOR THE CONVENIENCE OF THE CONTRACTOR. HOWEVER, ALL
ISOLATED WORK AREAS ARE NOT NOTED. SHOULD A CONDITION OCCUR THAT IS NOT SPECIFICALLY NOTED, THE CONTRACTOR SHALL PROCEED WITH WORK PER GENERAL DEMOLITION NOTES OR A SPECIFIC WORK NOTE(S) USED IN OTHER SIMILAR CONDITIONS, WHICHEVER IS MORE STRINGENT, PER APPROVAL
OF THE GOVERNMENT.
2. REFER ALSO TO SELECTED DEMOLITION, SUMMARY OF WORK, GOVERNMENT SOLICITATION
REQUIRMENTS AND OTHER SPECIFICATION SECTIONS REQUIRED.
3. REFER TO OTHER DISCIPLINES TO INCLUDE BUT NOT LIMITED TO LANDSCAPE, CIVIL, PLUMBING, MECHANICAL, AND STRUCTURAL FOR ADDITIONAL DEMOLITION AND REPARATION REQUIREMENTS. PATCH
ALL LOCATIONS REQUIRED BY PLUMBING, MECHANICAL, AND ELECTRICAL DEMOLITION. MATCH
ADJACENT CONDITIONS, UNLESS OTHERWISE NOTED. ALL REQUIRED TRENCHING AND REPLACEMENT OF
EXISTING SLABS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
4. CONTRACTOR TO REPAINT ALL EXTERIOR HOLLOW METAL FRAMES. BOTH INTERIOR AND EXTERIOR OF
FRAME TO BE PAINTED.
5. CONTRACTOR TO ASSUME ALL CONCRETE INDICATED TO BE REMOVED IS REINFORCED.
SPECIFIC DEMOLITION NOTES:
REMOVE EXISTING DOOR AND FRAME. SHORE EXISTING OPENING AND PREPARE FOR NEW CMU BLOCK,INFILL
REMOVE EXISTING LOUVER. SHORE EXISTING OPENING AND PREPARE FOR NEW CMU BLOCK, INFILL
CUT OPENING IN PREPARATION FOR INSTALLATION OF NEW DOOR. PROVIDE TEMPORARY SURPPORT UNTIL
NEW HEADED AN BE INSTALLED.
REMOVE PORTION OF INTERIOR WALL TO ADD NEW DOORS
REMOVE EXISTING FLOOR SLAB IN LOCATION MARKED IN PREPARATION FOR NEW WORK
REMOVE EXISTING INTERIOR WALLS, DOORS AND WALL HEATERS IN THEIR ENTIRETY
REMOVE EXISTING LOUVER. MODIFY OPENING AS REQUIRED TO INSTALL NEW LOUVER - SEE MECHANICAL
REMOVE EXISTING DOOR AND FRAME MODIFY OPENING AS REQUIRED TO ACCEPT NEW SCHEDULED OPENING
REMOVE EXISTING CURBS AS REQUIRED TO INSTALL GROUT LEVELING WITH MINIMUM 2" THICKNESS
THROUGHTOUT ENTIRE FLOOR AREA.
3/32" = 1'-0"A1.0
1 FIRST FLOOR DEMOLITION PLAN
3/32" = 1'-0"A1.0
2 NORTHEAST DEMOLITION ELEVATION
3/32" = 1'-0"A1.0
3 SOUTHEAST DEMOLITION ELEVATION
3/32" = 1'-0"A1.0
4 SOUTHWEST DEMOLITION ELEVATION
Rev. Description Date
GCJ
266 SF
HVAC
62 SF
SERVER
1200 SF
SCIF WORK
AREA
63 SF
MEN'S
63 SF
WOMEN'S
52 SF
MANLOCK
149 SF
CONFERENCE
EXISTING FIRE WATER RISER
NEW DOMESTIC WATER RISER
RELOCATED HVAC UNITS - SEE
MECHANICAL
A2.1
A2.1
A6.1
B3
B3
B3
C3
E3
C3
B3
B3
C3 B3
C3
A3
B3
B3
B3
A3
B3
B3
C3
/4
5' - 7 1/2"
A6
1025B
1025A
3,43,4
3,4
3,4
3,4
3,4
4' - 7 1/4" 11' - 10 3/4" 13' - 6 1/2"
/4
5' - 9 1/2"4' - 6"
3,4
3,4
1. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL WALLS ( INCLUDING STRUCTURE, FINISH,
AND INSULATION) SHALL EXTEND TO UNDERSIDE OF ROOF DECK ABOVE.
DIMENSION NOTES: ALL DIMENSIONS ARE MEASURED AS FOLLOWS:
- INTERIOR STUD WALLS ARE DIMENSIONED TO THE CENTER LINE OF THE WALL
- CMU WALLS ARE DIMENSIONED TO THE FACE OF THE CMU.
- CONTRACTOR TO FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO LAYING OUT THE
WORK. NOTIFIY THE GOVERNMENT OF ANY DEVIATIONS THAT COULD IMPACT THE DESIGN.
LEGEND
WALL TAG
# SPECIFIC NOTE TAG
GYPSUM CONTROL JOINT - REFER TO DETAIL 6/A2.4
GENERAL NOTESSPECIFIC NOTES
1 WALLS IN THESE AREAS TO RECEIVE ADDITIONAL FINISHES.
WALL TAGS ARE INTENDED TO IDENTIFY GENERAL WALL
ASSEMBLY REQUIREMENTS. REFER TO INTERIOR
ELEVATIONS. SUBSTITUTION OF CEMENTITIOUS BOARD FOR
GYPSUM WALL BOARD IS REQUIRED WHERE WALL IS
SCHEDULED TO RECIEVE TILE.
DOOR TAG202A
SECTION TAG ELEVATION TAG
2 EXTERIOR WALLS TO RECIEVE ALL NEW PAINT
A101
Ref
1Re f
1 Re f
Ref
A101
SIM
SAPF PERIMETER MEETING ICD 705, STC 50
NOTES: ALL FURNITURE SHOWN ON PLAN IS NOT INCLUDED IN CONTRACT AND IS PROVIDED FOR GENERAL INFORAMTION ONLY.
- FINISH AND PAINT SHEETROCK ALL THE WAY FROM
CONCRETE FLOOR SLAB TO UNDERSIDE OF ROOF DECK .
(INCLUDING AREAS CONCEALED ABOVE CEILINGS) ON BOTH
SIDES OF INTERIOR WALLS AND ON INTERIOR SIDE OF
EXTERIOR WALLS. CONTINUE ON UNDERSIDE OF ROOF
SYSTEMS - REFER TO SECTIONS
REFER TO 6/A2.1 AND 4/A3.2. PROVIDE MULTI-LAYER
GYPSUM EXTERIOR WALL AND CEILING ASSEMBLY IN THESE
SPACES AS REQUIRED BY ICD-705
4 REFER TO SPECIFICATION SECTION 03 5416 AND WALL
SECTIONS. PREPARE EXISTING CONCRETE SUBSTRATE AS
REQUIRED AND INSTALL HYRAULIC CEMENT LEVELING
UNDERLAYMENT (IN A TWO COATED APPLICATION) AS
REQUIRED TO LEVEL EXISTING FLOORS PRIOR TO
INSTALLATION OF NEW WALLS AND FLOOR COVERINGS.
SILL
PLAN
HEAD
5/8" GYPSUM WALL BOARD
ACOUSTICAL INSULATION
**NOTE: IF WALL IS SCHEDULED TO
RECEIVE TILE, PROVIDE CONCRETE
BOARD AND WATERPROOFING FOR
TILE INSTALLATION. REFER TO FINISH
SCHEDULE, INTERIOR ELEVATIONS AND
SECTIONS, AND GYPSUM BOARD
ASSEMBLIES SPECIFICATIONS FOR
TYPES AND OTHER
SUBSTRATE/FURRING REQUIREMENTS**
TYPE A
SILL
PLAN
HEAD
2 LAYERS OF 5/8" GYPSUM WALL BOARD WITH JOINTS
STAGGERED. TAPE AND MUD FIRST LAYER. TAPE, MUD,
FINISH TO A LEVEL 4 FINISH, AND PAINT SECOND LAYER.
ACOUSTICAL INSULATION
**NOTE: IF WALL IS SCHEDULED TO
RECEIVE TILE, PROVIDE CONCRETE
BOARD AND WATERPROOFING FOR
TILE INSTALLATION. REFER TO FINISH
SCHEDULE, INTERIOR ELEVATIONS AND
SECTIONS, AND GYPSUM BOARD
ASSEMBLIES SPECIFICATIONS FOR
TYPES AND OTHER
SUBSTRATE/FURRING REQUIREMENTS**
TYPE B
ACOUSTIC SEALANT
ACOUSTIC SEALANT
SILL
PLAN
HEAD
5/8" GYPSUM WALL BOARD
ACOUSTICAL INSULATION
**NOTE: IF WALL IS SCHEDULED TO
RECEIVE TILE, PROVIDE CONCRETE
BOARD AND WATERPROOFING FOR
TILE INSTALLATION. REFER TO FINISH
SCHEDULE, INTERIOR ELEVATIONS AND
SECTIONS, AND GYPSUM BOARD
ASSEMBLIES SPECIFICATIONS FOR
TYPES AND OTHER
SUBSTRATE/FURRING REQUIREMENTS**
TYPE C
SILL
PLAN
HEAD
ACOUSTICAL INSULATION
**NOTE: IF WALL IS SCHEDULED TO
RECEIVE TILE, PROVIDE CONCRETE
BOARD AND WATERPROOFING FOR
TILE INSTALLATION. REFER TO FINISH
SCHEDULE, INTERIOR ELEVATIONS AND
SECTIONS, AND GYPSUM BOARD
ASSEMBLIES SPECIFICATIONS FOR
TYPES AND OTHER
SUBSTRATE/FURRING REQUIREMENTS**
TYPE E
ACOUSTIC SEALANT
ACOUSTIC SEALANT
2 LAYERS OF 5/8" GYPSUM WALL BOARD ON BOTH SIDES.
STAGGER JOINTS (BOTH SIDES). TAPE AND MUD FIRST
LAYER (BOTH SIDES). TAPE, MUD, FINISH TO A LEVEL 4
FINISH, AND PAINT SECOND LAYER (BOTH SIDES)
PARTITION TAG LEGEND
1. THE FIRST CHARACTER IN THE TAG REFERENCES THE PARTITION TYPE
2. THE SECOND CHARACTER IN THE TAG REFERENCES THE THICKNESS OF
THE STRUCTURE (CMU, METAL STUD, WOOD, ETC.)
* REFER TO INTERIOR ELEVATIONS AND ASSOCIATED WALL SECTIONS
AND DETAILS FOR ADDITIONAL FURRING REQUIREMENTS AND FINISHES
NOT SHOWN ON WALL TYPE PLAN SCHEDULE
**NOTE - REFER TO LIFE SAFETY PLAN FOR PARTITION RATINGS**
1 2
A3.2
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A2.1
FLOOR PLANS
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
3/16" = 1'-0"A2.1
2 FIRST FLOOR/WALL TYPE PLAN
1 1/2" = 1'-0"A2.1
1 PARTITION TYPE A
A6 6" 7 1/4" A3 3 5/8" 4 7/8"
TYPE STUD... PARTITION THICKNESS
1 1/2" = 1'-0"A2.1
3 PARTITION TYPE B
1 1/2" = 1'-0"A2.1
4 PARTITION TYPE C
1 1/2" = 1'-0"A2.1
5 PARTITION TYPE E
B3 3 5/8" 4 7/8"
TYPE STUD THICKNESS PARTITION THICKNESS
C3 3 5/8" 4 7/8"
TYPE STUD THICKNESS PARTITION THICKNESS
E3 3 5/8" 4 7/8"
TYPE STUD THICKNESS PARTITION THICKNESS
3/16" = 1'-0"A2.1
6 WALL SECTION DETAIL
PNT1: MAIN WALL COLOR
Manufacturer: Sherwin Williams Color: Requisite Gray SW7023
PNT 2: MAIN INTERIOR DOOR COLOR
Manufacturer: Sherwin Williams Color: Urbane Bronze SW7048
PNT 3: DRYWALL FOR CEILINGS
Manufacturer: Sherwin Williams Color: Snowbound SW7004
PNT 4: BATHROOM WALL PAINT COLOR
Manufacturer: Sherwin Williams Color: Foggy Day SW6235
PNT 5: EXTERIOR DOORS/ FRAMES
Manufacturer: Sherwin Williams Color: Urbane Bronze SW7048
CPT1: Manufacturer: Shaw Contract Style: Memory Tile Color: Nestle Size: 24" x 24" Install Method: Monolithic
RB1: RUBBER BASE
Manufacturer:Roppe Color: P178 Pewter
TB1: TILE BASE
Manufacturer: Daltile Style: Exquisite Color: Ivory EQ10 Size: Cove Base 6 x 12 Shape Number: P36C9
HT1: Manufacturer: Daltile Style: Exquisite Color: Ivory EQ10 Size: 12 x 24 Install Pattern: 1/3 Ashlar
CARPET TILE
RUBBER BASEFLOOR TILE PAINT
SC: Sealed Concrete See Spec Section: 09 9123
CONCRETE
FINISH SCHEDULE LEGEND
ACT1: Style: Mineral Fiber, Beveled Tegular Size: 24"x24" Color: White Suspension System: 15/16" Exposed Tee
ACT2: Style: Vinyl Coated, Square edge Size: 24"x24" Color: White Suspension System: 15/16" Exposed Tee
ACOUSTIC CEILING
STATIC DISSIPATIVE TILE
SDT: Manufacturer: Armstrong Type: Excelon SDT Tile Color: Armor Gray 51951
SOLID SURFACE (@ HAND DRYERS)
SS1: Manufacturer: Corian Color: Cameo White Edge Finish: Beveled
1.) ALL WALL PAINT TO EXTEND TO DECK WHEN CEILING IS EXPOSED. PAINT EVERYTHING
EXPOSED TO VIEW INCLUDING BUT NOT LIMITED TO FIRE PROTECTION, STRUCTURAL,
MECHANICAL, ELECTRICAL.
2.) PAINT TEST AREA OF ALL PAINT COLORS FOR GOVERNMENT'S APPROVAL BEFORE
PROCEEDING.
GENERAL NOTES:
1.) SOLID SURFACE BEHIND THE HAND DRYER
2.) CEILINGS ARE TO BE CONSTRUCTED WITH TWO LAYERS OF 5/8" GYPSUM AT ROOF
LEVEL- SEE A3.2. TAPE AND MUD FIRST LAYER. TAPE, MUD, FINISH, AND PAINT SECOND
LAYER REGARDLESS OF IF SPACE IS SCHEDULED TO RECEIVE ACOUSTICAL TILE CEILING
CONCEALING GYPSUM CEILING.
3.) USE MOLD RESISTANT GYPSUM WALL BOARD IN ALL RESTROOMS.
4.) SEE ENLARGED PLANS AND ELEVATIONS.
5.) PAINT EXTERIOR PORTIONS OF DOOR/ FRAME PNT5.
SPECIFIC NOTES:
266 SF
HVAC
62 SF
SERVER
1200 SF
SCIF WORK
AREA
63 SF
MEN'S
63 SF
WOMEN'S
52 SF
MANLOCK
149 SF
CONFERENCE
TILE
LEGEND
CONC.
CARPET SDT
ACT1:
SEE FINISH SECHEDULE
SECTION 09 5100 -
ACOUSTICAL CEILINGS
SEE FINISH SCHEDULE
SECTION 09 5100 -
ACOUSTICAL CEILINGS
ACT2:
GWB:
SEE FINISH SECHEDULE
SECTION 09 2116 -
GYPSUM BOARD ASSEMBLIES
EXISTING CEILING
AND STRUCTURE
ETR:
LIGHT FIXTURE - SEE ELECTRICAL
EXISTING ROOF GIRTS
EXISTING STRUCTURAL FRAME
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A3.1
FINISH
SCHEDULES
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
FIRST FLOOR FINISH SCHEDULE
NO. ROOM NAME
FLOOR WALL CEILING DOORS MILLWORK
NOTESFINISH BASE FINISH
FINISH
MATERIAL FINISH FINISH CASING & TRIM CASEWORK COUNTERTOPNORTH WALL EAST WALL SOUTH WALL WEST WALL
GROUND LEVEL
1020 HVAC CONCRETE RB1 PNT1 PNT1 PNT1 PNT1 EXISTING PNT3 PNT2 PNT2 5
1021 SERVER SDT RB 1 PNT1 PNT1 PNT1 PNT1 GWB (NOTE 2) ACT1 PNT2 PNT2 2
1023 MEN'S HT1 TB 1 PNT4 PNT4 PNT4 PNT4 GWB (NOTE 2) ACT2 PNT2 PNT2 1, 2, 3, 4
1024 WOMEN'S HT1 TB 1 PNT4 PNT4 PNT4 PNT4 GWB (NOTE 2) ACT2 PNT2 PNT2 1, 2, 3, 4
1025 MANLOCK CPT1 RB 1 PNT1 PNT1 PNT1 PNT1 GWB (NOTE 2) ACT1 PNT2 PNT2 1,2,5
1026 SCIF WORK AREA CPT1 RB 1 PNT1 PNT1 PNT1 PNT1 GWB (NOTE 2) PNT 3 PNT2 PNT2 1,2,5
1027 CONFERENCE CPT1 RB 1 PNT1 PNT1 PNT1 PNT1 GWB ACT1 PNT2 PNT2 1,2
1/8" = 1'-0"A3.1
1 FINISH FIRST FLOOR PLAN
NOTE: FLOOR PATTERNS ARE FOR DIAGRAMATIC PURPOSES ONLY. REFER TO ENLARGED
FLOOR PLANS, SPECIFICATIONS, AND FINISH LEGEND FOR ACTUAL INSTALLATION PATTERNS.
1/8" = 1'-0"A3.1
2 REFLECTED CEILING PLAN
PROVIDE HOLD OPEN CLIPS FOR ALL CEILING TILES IN VESTIBULE 1025.
WIDTH
SCHEDULED FRAME
2"2"
S C H
ED
U
LE
D H
EI
G
H T
SAPF- F3
EXTERIOR SECURE ACCESS
PROGRAM FACILITY
SAPF ENTRANCE
FRAME
HM F1
HOLLOW METAL
FRAME
WIDTH
SCHEDULED DOOR
2"2"
S C H
ED
U
LE
D H
EI
G
H T
HM F2
HOLLOW METAL
FRAME
WIDTH
SCHEDULED FRAME
2"2"
S C H
ED
U
LE
D H
EI
G
H T
"2
WIDTH
SCHEDULED DOOR
S C H
ED
U
LE
D H
EI
G
H T
SAPF-3
SECURE ACCESS
PROGRAM FACILITY
ENTRANCE DOOR
DOOR
SCHEDULED WIDTH
S C H
ED
U
LE
D H
EI
G
H T
F HM
FLUSH
HOLLOW METAL
DOOR
DOOR
SCHEDULED WIDTH
S C H
ED
U
LE
D H
EI
G
H T
F HM EXT
INSULATED FLUSH
HOLLOW METAL
EXTERIOR DOOR
INSULATION
MTL STUD FRAMING
CMU
CONT. BACKER ROD & SEALANT,
TYP. BOTH SIDES - 3/8" MIN.
FILL WITH GROUT IN
ACCORDANCE WITH ICD
705 REQUIREMENTS
STC 50 RATED DOOR -
SEE SCHEDULE
SILL DETAIL
STC 50 RATED DOOR -
SEE SCHEDULE
HOLLOW METAL FRAME BEYOND
ALUMINIUM THRESHOLD SET IN
FULL BED OF SEALANT - SEE
HARDWARE SCHEDULE
PEJ
MTL STUD FRAMING
GYMSUM WALLBOARD
INSULATION
CMU
STC 50 RATED DOOR -
SEE SCHEDULE
CONTINUOUS BACKER ROD &
SEALANT 3/8" MIN. (BOTH
SIDES)
MASONRY "T" ANCHOR, SEE
SPECIFICATIONS FOR SPACING
REQUIREMENTS
JAMB DETAIL
HEAD DETAIL
CMU BOND BEAM, (2) #5 AT
BOTTOM. 16" MIN. BEARING EACH
SIDE.
WALL FLASHING
GYPSUM WALLBOARD
CORNER BEAD
ACOUSTIC DOOR
FRAME - SEE DOOR
SCHEDULE
CORNER BEAD
FILL WITH GROUT IN
ACCORDANCE WITH ICD
705 REQUIREMENTS
ACOUSTIC DOOR
FRAME - SEE DOOR
SCHEDULE
EXISTING CMU TO REMAIN 6X6X3/8" ANGLE SHORING
BEAR 24" EACH SIDE OF
NEW OPENING AS REQUIRED
TO INSTALL NEW LINTEL
REMOVE AND PATCH
MASONRY MORTAR
FOLLOWING INSTALLATION
OF NEW LINTEL AND JAMB
BLOCKS
EXISTING CMU TO REMAIN
#5 BAR - DOWEL INTO EXISTING
FOUNDATION WALL WITH 8"
EMBEDMENT. LAP SPLICE AS
REQUIRED AND CONTINUE
JAMB REINFORCEMENT
THROUGH LINTEL ABOVE
GYPSUM WALLBOARD
BATT INSULATION
METAL STUD JAMB / HEAD FRAMING,
SEE STRUCTURAL
SEALANT, TYPICAL EACH SIDE
FRAME TYPE VARIES, SEE DOOR
SCHEDULE
SEE DOOR SCHEDULE
1/2" 1/2"
WALL TYPE PLAN
SEE
EXISTING ROOF
ACOUSTIC SEALANT
NEW GYPSUM WALLBOARD (2 LAYERS)
NEW INSULATION
NEW MTL STUD FRAMING
EXISTING CMU WALL (PAINT)
NEW CMU WALL (PAINT)
FINISH FLOOR
FLOOR LEVELER
NEW CONCRETE
EXISTING SLAB
A3.2
NOTE: ALL EXTERIOR WALLS AND ROOFS WITHIN SECURE AREAS TO
BE PROVIDED WITH METAL FRAMING, INSULATION, AND GYPSUM
WALLBOARD INDICATED ON THIS DRAWING. FIRST LAYER OF
GYPSUM BOARD TO BE TAPED AND MUDDED. SECOND LAYER OF
GYPSUM BOARD TO BE TAPED, MUDDED, FINISHED, AND PAINTED
WITH JOINTS STAGGERED FROM BASE LAYER. PAINT ENTIRE EXTENT
OF NEW GYPSUM WALL/ROOF ASSEMBLY.
NEW GYPSUM WALLBOARD (2 LAYERS)
NEW INSULATION
NEW MTL STUD FRAMING
A3.2
Sim
ACOUSTIC SEALANT
FRAMING
INSULATION
GYPSUM BOARD
CORNER BEAD
SIGN TYPE: A
6"
EXIT
SIGN TYPE: B
8"
NO
EXIT
SIGNAGE SCHEDULE
NOTE: ALL SIGNS SHALL
COMPLY WITH NFPA 101
AND ANSI A117.1
SIGN TYPE: C
8"
ROOM 100
ROOM NAME
CHANGABLE
WINDOW PLAQUE
SIGN TYPE: D
8"
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A3.2
DOOR SCHEDULE,
SECTION, &
DETAILS
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
DOOR, OPENING & FRAME SCHEDULE
DOOR
NO.
DOOR FRAME
GLAZING TYPE
DETAILS
SIGN TYPE COMMENTSWIDTH HEIGHT THICKNESS LEAVES TYPE WIDTH TYPE
HEAD
DETAIL JAMB DETAIL
SILL
DETAIL
GROUND LEVEL
1020 3' - 0" 7' - 0" 0' - 1 3/4" 2 F HM EXT 6' - 0" HM F2 2/A3.2 2/A3.2 2/A3.2 C
1021 3' - 0" 7' - 0" 0' - 1 3/4" 1 F HM 3' - 0" HM F1 3/A3.2 3/A3.2 SIM B
1023 3' - 0" 7' - 0" 0' - 1 3/4" 1 F HM 3' - 0" HM F1 3/A3.2 3/A3.2 SIM D
1024 3' - 0" 7' - 0" 0' - 1 3/4" 1 F HM 3' - 0" HM F1 3/A3.2 3/A3.2 SIM D
1025A 3' - 0" 7' - 0" 0' - 1 3/4" 1 SAPF-3 3' - 0" SAPF-F3 2/A3.2 2/A3.2 2/A3.2 A STC-50
1025B 3' - 0" 7' - 0" 0' - 1 3/4" 1 F HM 3' - 0" HM F1 3/A3.2 3/A3.2 SIM A, C
1026 3' - 0" 7' - 0" 0' - 1 3/4" 1 SAPF-3 3' - 0" SAPF-F3 2/A3.2 2/A3.2 2/A3.2 A STC-50
1027 3' - 0" 7' - 0" 0' - 1 3/4" 1 F HM 3' - 0" HM F1 3/A3.2 3/A3.2 SIM A, B, C
3" = 1'-0"A3.2
2 SAPCA ACOUSTICAL HOLLOW METAL EXTERIOR DETAIL - MASONRY ON CMU
3" = 1'-0"A3.2
3 TYP DOOR HEAD DETAIL (JAMB SIM)
1/2" = 1'-0"A3.2
4 WALL SECTION DETAIL - Callout 1
1 1/2" = 1'-0"A3.2
5 ROOF/WALL STRUCTURE WRAP DETAIL
A6.1 2
A6.1
SIM
1' - 8"
I
BF
E
G
F B E
I
C
C
A
A
J
J
3' - 6 7/8"
1' - 6"
3' - 6 7/8"
1' - 6"
63 SF
WOMEN'S
63 SF
MEN'S
K
G
K
L
L
PNT 4
I J
C
HT-1
M
L
A6
PNT 4
G
E
F
J
A
I
B
HT-1
M
PNT 4
F
E
B
G
HT1
PNT 4
C
1' - 9"
F
HT1
SS1
K
Sheet Number
Sheet Title
Project Title
M on tg om er y
D ot ha n
W W
W .S
SL
A
R C
H .C
O M
(M ) 3
. 2
. 5
(D
) 3
. 7
. 5
Job Number
Date
Drawn By
Checked By
A
RC
H
IT
E
CT
U
RE
IN
TE
RI
O R
D E
SI
G
N
A6.1
ENLARGED FLOOR
PLANS
RE
N
O V
A
TE
B
LD
G
Su m pt er
S m ith Jo in t N at io na l G ua rd
B as e Bi rm in gh am
, A L
19059 / BRKR212008
MAY 2023
NV/HK
DCD
3/8" = 1'-0"A6.1
1 ENLARGED RESTROOM PLAN
1/2" = 1'-0"A6.1
2 FIRST FLOOR RESTROOM ELEVATION A
1/2" = 1'-0"A6.1
3 FIRST FLOOR RESTROOM ELEVATION B
1/2" = 1'-0"A6.1
4 FIRST FLOOR RESTROOM ELEVATION C
1/2" = 1'-0"A6.1
5 FIRST FLOOR RESTROOM ELEVATION D
GENERAL NOTES:
1. REFER TO SPEC SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES
FOR TOILET AND BATH ACCESSORIES SCHEDULE.
2. PROVIDE AND INSTALL CONCEALED WOOD BLOCKING IN STUD FRAMING WALLS
FOR SECURING TOILET ACCESSORIES AND TOILET PARTITIONS PER
MANUFACTURERS RECOMMENDATION PRIOR TO INSTALLING SUBSTRATES AND
FINISH WALL MATERIALS.
3. LOCATE AND INSTALL TOILET ACCESSORIES AT HEIGHTS AND DISTANCES
COMPLYING WITH ICC A117.1 (LATEST EDITION), ABA (LATEST EDITION), AND
MANUFACTURERS INSTALLATION RECOMMENDATIONS FOR COMPLYING WITH
ABA.
4. REFER TO PLUMBING FOR ADDITIONAL REQUIREMENTS.
5. PROVIDE 3/4" THICK QUARTZ SS1 AS SHOWN BEHIND ELECTRIC HAND-DRYER AS
SHOWN IN ROOMS 1023 AND 1024. QUARTZ TO PROJECT OUT FROM GYPSUM
WALL BOARD 3/4". THE RUBBER BASE SHALL TERMINATE IN THE 1/4" QUARTZ
PROJECTION.
Project Title
M o n tg o m er y
D o th an
W W W .S S L A R C H .C O M
(M
D
Job Number
Date
Drawn By
Checked By
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
No. Revision Date
S S
L
MAY 2023
EK
EK
R E
N O
V A
T E
B L
D G
S u m p te r S m it h
J o in t
N at io n al G u ar d B as e
B ir m in gh am
A
L
19059 / BRKR212008
FD1.1
D P
R O
J E C
T
C o n v e r t
B u i l d i n g t
S C
I F D
W G
M e c h
F D d w g
P
M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PETERSON ENGINEERING INC.
AutoCAD SHX Text
75 SOUTH "F" STREET
AutoCAD SHX Text
PENSACOLA, FLORIDA 32502
AutoCAD SHX Text
(850) 434-0513
AutoCAD SHX Text
(PROF. ENG. #: 3600)
AutoCAD SHX Text
PEI 21183
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text K
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text No. 90730 9073090730
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text N
AutoCAD SHX Text
%%UFIRE PROTECTION DEMO PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text 1/4"= 1'-0"
AutoCAD SHX Text 5'
AutoCAD SHX Text 5'
AutoCAD SHX Text
AutoCAD SHX Text
FIRE PROTECTION DEMOLITION PLAN
AutoCAD SHX Text
SHEET NOTES
AutoCAD SHX Text
AutoCAD SHX Text CONTRACTOR SHALL DEMOLISH THE EXISTING PREACTION SPRINKLER SYSTEM COMPLETELY. LOCATION OF EXISTING FIRE RISER. CUT EXISTING FIRE SPRINKLER RISER FLUSH CUT EXISTING FIRE SPRINKLER RISER FLUSH WITH FLOOR AND FILL WITH CONCRETE TO MATCH EXISTING FLOOR FINISH. THE EXISTING FIRE ALARM SYSTEM IN THE BUILDING SHALL BE DEMOLISHED IN ITS ENTIRETY. DEMOLITION INCLUDES BUT IS NOT LIMITED TO THE FACP, TRANSMITTER, ALL ASSOCIATED DEVICES, CONDUITS, WIRING, AND COMPONENTS. CONTRACTOR SHALL FIELD VERIFY LOCATION OF ALL EXISTING FIRE ALARM COMPONENTS TO BE REMOVED. DEVICES ARE NOT SHOWN ON THIS PLAN. PIPING UNDER BUILDING SHALL BE ABANDONED IN PLACE. DEMOLISH FIRE WATER SUPPLY FROM EDGE OF BUILDING BACK TO EXISTING TEE FITTING FOR FIRE HYDRANT. CAP AND SEAL PIPING AT TEE FITTING. REMOVE EXISTING PIV. SEE CIVIL DRAWING C1.1 FOR ALL UNDERGROUND FIRE WATER SUPPLY DEMOLITION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTE: FIRE SUPPRESSION IS NOT REQUIRED IN THE RENOVATED FACILITY THIS FACILITY DOES NOT EXCEED THE THRESHOLD CRITERIA FOR FIRE SUPPRESSION IN UFC 3-600-01 OR NFPA 101. THE GOVERNMENT HAS DETERMINED AUTOMATIC SPRINKLER OR OTHER FIRE SUPPRESSION SYSTEM IS NOT REQUIRED FOR THE RENOVATED FACILITY PER UFC 3-600-01 1-12.8. NOTE: FIRE ALARM SYSTEM IS NOT REQUIRED IN THE RENOVATED FACILITY THIS FACILITY DOES NOT EXCEED THE THRESHOLD CRITERIA FOR FIRE SUPPRESSION IN UFC 3-600-01 OR NFPA 101 AND THEREFORE FIRE ALARM SYSTEM IS NOT REQUIRED FOR THE RENOVATED FACILITY. NOTE: MASS NOTIFICATION SYSTEM IS REQUIRED IN THE RENOVATED FACILITY MASS NOTIFICATION SYSTEM IS REQUIRED IN THE RENOVATED FACILITY THIS FACILITY IS CONSIDERED AN "INHABITED BUILDING" AS DEFINED IN IN UFC 4-010-01 AND THEREFORE A MASS NOTIFICATION SYSTEM IS REQUIRED IN THE BUILDING PER UFC 4-021-01. SEE DRAWING SHEET MN1.1 FOR MASS NOTIFICATION SYSTEM REQUIREMENTS
AutoCAD SHX Text
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text EXISTING LEAD IN TO BE CUT FLUSH WITH EXISTING FINISHED FLOOR. FILL WITH CONCRETE AND FINISH TO MATCH FLOOR.
AutoCAD SHX Text
NEW CONCRETE
AutoCAD SHX Text
EXISTING FIRE PROTECTION LEAD IN TO BE ABANDONED IN PLACE
AutoCAD SHX Text
PACKED EARTH TO CREATE BASE FOR NEW CONCRETE
AutoCAD SHX Text
EXISTING UNDERGROUND FIRE WATER SUPPLY SHALL BE DEMOLISHED TO EDGE OF BUILDING.
AutoCAD SHX Text %%uEXISTING RISER DEMOLITION DETAIL
AutoCAD SHX Text
SCALE: 1/8"= 1'-0
Project Title
M o n tg o m er y
D o th an W W W .S S L A R C H .C O M
(M
D
Job Number
Date
Drawn By
Checked By
A R
C H
IT
E
C T
U R
E
I N
T E
R
IO
R D
E S
IG
N
No. Revision Date
S S
L
MAY 2023
GDP
SCJ
R E
N O
V A
T E
B L
D G
S u m p te r S m it h
J o in t
N at io n al G u ar d B as e
B ir m in gh am
A
L
19059 / BRKR212008
No. 14380
PROFESSIONAL
P1.1
D :\P
RO
JE
CT
\2
1\
Co nv er t B ui ld in g to
S
CI
F\ D
W G\
Pl um bi ng
\2
P
1.
1.
dw g, /1
2/
:4 8:
A
M , D
W G
To P
D F.
pc
AutoCAD SHX Text 4"
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MANLOCK
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
AutoCAD SHX Text
SCIF WORK
AutoCAD SHX Text
SERVER
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
AutoCAD SHX Text
4" TWO-
AutoCAD SHX Text
WAY CO
AutoCAD SHX Text 3"
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text 2"
AutoCAD SHX Text 3"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text
3"VTR
AutoCAD SHX Text
3"FD
AutoCAD SHX Text
3"FD
AutoCAD SHX Text P-1
AutoCAD SHX Text P-1
AutoCAD SHX Text P-2
AutoCAD SHX Text P-2
AutoCAD SHX Text P-3
AutoCAD SHX Text D
AutoCAD SHX Text
CD
AutoCAD SHX Text
BFP-1
AutoCAD SHX Text 1"
AutoCAD SHX Text
AHU-1B
AutoCAD SHX Text
AHU-1A
AutoCAD SHX Text
CD
AutoCAD SHX Text
SPLASH
AutoCAD SHX Text
BLOCK
AutoCAD SHX Text 1"
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
2"HUB DRAIN
AutoCAD SHX Text
ABOVE CEILING
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
CONDENSATE PIPING RUN
AutoCAD SHX Text
ABOVE CEILING TO HUB DRAIN
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
CONDENSATE PUMP
AutoCAD SHX Text
SEE SHEET M2.1
AutoCAD SHX Text
2"WCO
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
AutoCAD SHX Text
MANLOCK
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
AutoCAD SHX Text
SCIF WORK
AutoCAD SHX Text
SERVER
AutoCAD SHX Text
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
AutoCAD SHX Text P-1
AutoCAD SHX Text P-1
AutoCAD SHX Text P-2
AutoCAD SHX Text P-2
AutoCAD SHX Text P-3
AutoCAD SHX Text
BFP-1
AutoCAD SHX Text
HB
AutoCAD SHX Text
2" UP
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1-1/2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
IWH-1
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
AHU-1B
AutoCAD SHX Text
AHU-1A
AutoCAD SHX Text
PDI"A"
AutoCAD SHX Text
PDI"B"
AutoCAD SHX Text
PDI"A"
AutoCAD SHX Text
FULL PORT BALL
AutoCAD SHX Text
VALVE IN RISER
AutoCAD SHX Text
FULL PORT BALL
AutoCAD SHX Text
VALVE (TYPICAL)
AutoCAD SHX Text
WH
AutoCAD SHX Text
PDI"A"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 2"
AutoCAD SHX Text
PETERSON ENGINEERING INC.
AutoCAD SHX Text
75 SOUTH "F" STREET
AutoCAD SHX Text
PENSACOLA, FLORIDA 32502
AutoCAD SHX Text
(850) 434-0513
AutoCAD SHX Text
(PROF. ENG. #: 3600)
AutoCAD SHX Text
PEI 21183
AutoCAD SHX Text
PLUMBING PLAN - WASTE AND WATER
AutoCAD SHX Text N
AutoCAD SHX Text
%%UPLUMBING PLAN - WATER
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
%%UPLUMBING PLAN - WASTE
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
SCALE: 1/4"=…
This is the start of the file's text. The full file is on GovTribe.