Bid_Plans.pdf
PDF 3 MB Posted
- Solicitation number
- IFB- 26 - 132
- Issued by
- Pinellas County, Florida
About this file
This is a set of construction bid plans for the Neighborhood Crossings FY23 project (Project No. 23073-100) issued by the City of St. Petersburg, Florida. The plans document roadway safety improvement work at five intersections: 7th Street South at 18th Avenue South, Dr. MLK Jr. Street South at 30th Avenue South, Dr. MLK Jr. Street South at 38th Avenue South, 37th Street South at 26th Avenue South, and 37th Street South at 30th Avenue South. The scope of work includes construction of 440 square yards of concrete sidewalks, 962 linear feet of ADA-compliant concrete curbs, concrete curb ramps, detectable warning systems, pavement marking removal and installation, sign relocation and installation, rectangular rapid-flashing beacon (RRFB) assemblies, sodding, and storm drainage inlet installation. The plans provide detailed topographic surveys, utility locations, cross-sections, and standard construction details necessary for bidding. The bid release date is March 30, 2026, with a question deadline of April 16, 2026, and a response deadline of May 5, 2026, at 3:00 p.m. All submissions are required electronically through the OpenGov Procurement portal at https://procurement.opengov.com/portal/stpete.
Bidders must submit a Bid Bond or certified check equal to 5 percent of the Base Bid Price, and the successful bidder must furnish a Public Construction Bond equal to 100 percent of the Contract Price within ten days of award notification. The City of St. Petersburg has established a 10 percent Small Business Enterprise (SBE) participation goal, requiring submission of Form A letters of intent from certified SBE subcontractors or Form B non-use justification if the goal cannot be met. Contractors must demonstrate a minimum of three completed projects within five years with at least two including concrete sidewalk, curb ramp, signage, and pavement marking work, and one project of similar scope for a government agency, each exceeding $100,000 in value. The project superintendent must have successfully completed a minimum of three qualifying projects within the same timeframe. Contractors must comply with Florida Department of Transportation Standard Specifications for Road and Bridge Construction (2000 Edition) and various ASTM standards, and must provide a 25 percent completion rate using their own workforce unless approved otherwise. Up to 80 percent of the contract value may be subcontracted, with restrictions limited to first and second tier subcontractors. A contract allowance of $60,000 is established for contract amendments, and a one-year guarantee period is required for all materials and workmanship from the date of final completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Neighborhood_Crossings_-_FY23_(Project_No._23073-100).pdf | ||
| CITY_OF_ST_PETE_PURCHASING_82814-1_RECEIPT.pdf | ||
| Legal_Ad_Proof,_Runs_3_29.pdf | ||
| FILLABLE_BEP_NON-USE_BEP_FORM_B.pdf | ||
| Public_Construction_Bond.pdf | ||
| Base_Agreement.pdf | ||
| FILLABLE_LETTER_OF_INTENT_BEP-FORM_A.pdf | ||
| Bid_Bond_.docx | DOCX document | |
| Subcontractor_Summary_Spreadsheet.xlsx | XLSX spreadsheet | |
| Bidder_Security_Information.pdf | ||
| Bid_Plans.pdf | ||
| Contract_Specifications.pdf | ||
| Shelterd_BID_-_Subcontractor_Summary_Spreadsheet_.xlsx | XLSX spreadsheet | |
| Performance_&_Payment_Bond_.DOCX | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NEIGHBORHOOD CROSSINGS FY23
PROJECT NO. 23073-100
02/02/26
L IC E NS E
F L O R I D A
PLOTTING SYMBOLS
PROPOSEDEXISTINGAPPLICATION
PROPOSEDEXISTINGAPPLICATION
GENERAL LINESTYLES
APPROXIMATE
BENCH MARK, CITY CONTROLLED
BENCH MARK, TEMPORARY
BORING SITE
BUSH
CENTERLINE
CONCRETE MONUMENT
DELTA ANGLE
FOUND CONCRETE MONUMENT
FOUND IRON ROD
FOUND IRON PIPE
FOUND "X" CUT
NORTH ARROW
OVERLAND FLOW ARROW
REVISION
SURVEY NAIL AND DISK
SURVEY TRAVERSE POINT
SURVEY BASELINE
REVISION DESCRIPTION
B OR B/L L
N/A
N/A
N/A
N/A
N/A
N/A
℄ OR C/L
N/A
BASE LINE OF SURVEY
BUILDING WALL
CENTER LINE OF CONSTRUCTION
FENCE, LABEL HEIGHT AND TYPE
GUARD RAIL
HEDGE LINE, LABEL TYPE AND HEIGHT
TOP OF BANK
TREE OR WOOD LINE,
LABEL TYPE AND DIAMETER AT DBH
PROPOSEDEXISTINGAPPLICATION
PROPOSEDEXISTINGAPPLICATION
STRUCTURE SYMBOLSUTILITY POLE SYMBOLS
MANHOLE, CLEAN OUT
MANHOLE, ELECTRIC
MANHOLE, GAS
MANHOLE, SEWER
MANHOLE, STORM DRAIN
MANHOLE, TELEPHONE
METER, GAS
GUY WIRE/ANCHOR
JOINT USER POLE
LIGHT POLE
POWER POLE
TELEPHONE
P
G
S
D
T
G
CO
P
G
S
D
T
G
CO
TBM-BOX CUT
C.M.
CBM #XXXCBM #XXX
TBM-BOX CUT
℄ OR C/L
C.M
F.C.M.
FIP
FIR
FND. "X" CUT
N/A
BL OR B/L
S.D.
BL BL
N/A LC
PRESSURE PIPE SYMBOLS
APPLICATION EXISTING PROPOSED
AIR RELEASE
HYDRANT
HYDRANT & VALVE
METER, RECLAIMED WATER
METER, WATER
PLUG
REDUCER
TAP VALVE & SLEEVE
TEE
VALVE
VALVE W/BLOW OFF
UTILITY LINESTYLES
APPLICATION EXISTING PROPOSED
CABLE TV, BURIED
CABLE TV, OVERHEAD
FIBER OPTICS CABLE
FORCE MAIN
GAS MAIN
POWER, BURIED
POWER, OVERHEAD
RECLAIMED WATER
SANITARY SEWER
STORM DRAIN
TELEPHONE, BURIED
TELEPHONE, OVERHEAD
UNDERDRAIN
WATER MAIN
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
A
ABD ABANDONED
AC
ALT
APPROX
ASPH
ASPH CONC
AVE
ACRE
ALTERNATE
APPROXIMATE
ASPHALT
ASPHALTIC CONCRETE
AVENUE
B
BRIDGE BENCH MARKBBM
BC BOX CULVERT
B/C
BEG
BLDG
BLVD
BM
B.O.
BOT
BFV
B/W
B/L OR BL
BACK OF CURB
BEGIN
BUILDING
BOULEVARD
BENCH MARK
BLOW-OFF
BOTTOM
BUTTERFLY VALVE
BACK OF WALK
BASELINE OF SURVEY
C AND G
CB
CBM
CF
CI
CIP
C/L OR ℄
CIPL
CL
CLF
CM
CMP
CPP
CMPA
CO
CONC
CONST
CP
CSP
CTR
CY
CULV
CORR
CURB AND GUTTER
CATCH BASIN
CITY BENCH MARK
CUBIC FEET
CURB INLET
CAST IRON PIPE
CAST-IN-PLACE
CLEARANCE
CENTERLINE OF CONSTRUCTION
CONCRETE MONUMENT
CORRUGATED PLASTIC PIPE
CHAIN LINK FENCE
CORRUGATED METAL PIPE
CORRUGATED METAL PIPE ARCH
COUNTY OR CLEAN-OUT
CONCRETE
CONSTRUCT
CORRUGATED
CONCRETE PIPE
CORRUGATED STEEL PIPE
CENTER
CULVERT
CUBIC YARD
D
DBL
DEPT
DI
DIA
DIM
DIP
DOUBLE
DEPARTMENT
DROP INLET or DUCTILE IRON
DIAMETER
DIMENSION
DUCTILE IRON PIPE
E E
EA
EL OR ELEV
ELEC
EP
ESMT
E.W. OR E/W
EXIST
EAST
EACH
ELEVATION
ELECTRIC
EDGE OF PAVEMENT
EASEMENT
EACHWAY
EXISTING
FCM
FH
FIP
FIR
FL
F.M.
F/C
FOUND CONCRETE MONUMENT FIRE
HYDRANT
FOUND IRON PIPE
FOUND IRON ROD
FLOW LINE
FORCE MAIN
FACE OF CURB
F
G
GALV
GI
GSP
GR
GRND
GUT OR GTTR
GV
GALVANIZED
GRATE INLET
GALVANIZED STEEL PIPE
GRADE
GROUND
GUTTER
GATE VALVE
H
HDPE
HDWL
HNDRL
HP HW
HWY
HYD
HIGH DENSITY POLYETHYLENE PIPE
HEADWALL
HANDRAIL
HIGH POINT HIGH WATER
HIGHWAY
HYDRANT
I
IP
INSTL
INV
IRON PIPE
INSTALL
INVERT
J
JB JUNCTION BOX
L
LF LINEAR FEET
M (M)
MAX
MES
MH
MHW
MIN
MISC
MLW
MON
MPH
MSL
MEASURED DISTANCE
MAXIMUM
MITERED END SECTION
MANHOLE
MEAN HIGH WATER
MINIMUM
MISCELLANEOUS
MEAN LOW WATER
MONUMENT
MILES PER HOUR
MEAN SEA LEVEL
N N/A N
NE
NGVD
NIC
NW
NOT APPLICABLE
NORTH
NORTHEAST
NATIONAL GEODETIC VERTICAL DATUM
NOT IN CONTRACT OR NOT INCLUDED
NORTHWEST
O
OC
OVHD
ON CENTER
OVERHEAD
P (P)
PAVT/PVMT
PC
PI
PP
PVC
PVI
P/L OR PL
PLAT
PAVEMENT
POINT OF CURVATURE
POINT OF INTERSECTION
POWER POLE
POLYVINYL CHLORIDE
POINT OF VERTICAL INTERSECTION
PROPERTY LINE
R R
RCP
RCWM
RD
RDWY
RPM
RR OR R/R
R/W
RADIUS
REINFORCED CONCRETE PIPE
RECLAIMED WATER MAIN
ROAD
ROADWAY
RAISED PAVEMENT MARKER
RAILROAD
RIGHT-OF-WAY
S (CONT.)
SF OR SQ FT
SI OR SQ IN
SPEC
SY OR SQ YD
SR
ST
STA
STD
SW
S/W
SQUARE FOOT OR SQUARE FEET
SQUARE INCH
SPECIFICATION
SQUARE YARD
STATE ROAD
STREET
STATION
STANDARD
SOUTHWEST
SIDEWALK
T T
TBM
T.O.B.
T/C OR TOC
TEL
TWP
TYP
TANGENT
TEMPORARY BENCH MARK
TOP OF BANK
TOP OF CURB
TELEPHONE
TOWNSHIP
TYPICAL
U
UD
UG
UNDERDRAIN
UNDERGROUND
V
VAR
VC
VF
VCP
VERT
VARIES OR VARIOUS
VERTICAL CURVE
VERTICAL FOOT OR VERTICAL FEET
VITRIFIED CLAY PIPE
VERTICAL
W W
WM
WT
WEST
WATER MAIN
WATER TABLE, WEIGHT, OR WALL
C
D (CONT.)
DISP
DOT
DR
D/W
DWG
DISPOSAL
DEPARTMENT OF TRANSPORTATION
DRAIN
DRIVEWAY
DRAWING
S S
SAN
SD
SE
SECT
SEW
SOUTH
SANITARY
STORM DRAIN
SOUTHEAST
SECTION
SEWER
GENERAL NOTES
1. THE LOCATIONS(S) OF THE UTILITIES SHOWN IN THE PLANS ARE BASED ON LIMITED INVESTIGATION TECHNIQUES AND SHOULD BE CONSIDERED APPROXIMATE ONLY. THE VERIFIED LOCATIONS / ELEVATIONS APPLY ONLY AT THE POINT SHOWN. INTERPOLATIONS BETWEEN THESE POINTS HAVE NOT BEEN VERIFIED. UTILITIES SHALL REMAIN UNLESS OTHERWISE NOTED.
2. THE CONTRACTOR SHALL CALL THE SUNSHINE STATE ONE CALL OF FLORIDA, INC. AT 811 OR 1-800-432-4770 AND THE UTILITY OWNERS 48 HOURS BEFORE BEGINNING WORK. ALL UTILITY OWNERS MAY NOT BE A MEMBER, REQUIRING DIRECT CONTACT.
3. THE CONTRACTOR IS TO MAINTAIN AND KEEP STREET NAME IDENTIFICATION VISIBLE DURING CONSTRUCTION OPERATIONS, IN
ORDER TO FACILITATE EMERGENCY VEHICLE TRAFFIC.
THE CONTRACTOR IS HEREBY NOTIFIED THAT ABOVE GROUND OR UNDERGROUND UTILITIES MAY BE IN THE AREA OF THIS PROJECT AND ARE TO BE ADJUSTED BY OTHERS AS DIRECTED BY THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR
UTILITY COORDINATION.
UTILITY OWNERS:
COMPANY CONTACT TELEPHONE NUMBERS
CENTURYLINK NETWORK RELATIONS (877) 366-8344 ext. 3 CHARTER COMMUNICATIONS DUFFY McCLELLAND (352) 527-2189
CITY OF ST. PETERSBURG JEFFREY RZEWNICKI (727) 892-5384
DUKE ENERGY NATHAN LAJEUNESSE (407) 629-1010
FRONTIER COMMUNICATIONS SCOTT HAND (813) 431-0328
KNOLOGY BROADBAND OF FLORIDA CORY RICHMOND (727) 422-8040
TECO - PEOPLES GAS JENNA JACKSON (813) 275-3794
UNITI FIBER/SOUTHERN LIGHT TERRY YOUNG (251) 422-3872
CITY OF ST. PETERSBURG:
WATER RESOURCES MICHAEL RENSHAW (727) 892-5660
ENG. CONST. TOM RICE (727) 551-3202
STORMWATER OPS/TRANSPORTATION OPS MARSHALL HAMPTON (727) 892-5187
NEIGHBORHOOD TRANS (727) 893-7843
SANITATION WILLIE JOSEPH (727) 893-7954
TRAFFIC SIGNALS KEVIN JACKSON (727) 893-7478
4. THE CONTRACTOR SHALL SECURE THE NECESSARY PERMITS/RIGHT OF ENTRY FROM THE CITY OF ST. PETERSBURG FOR ANY WORK WITHIN THE CITY'S RIGHT-OF-WAY AND EASEMENTS. (THE LIST WILL BE AVAILABLE AT THE PRE-CONSTRUCTION MEETING.) THE CONTRACTOR SHALL ALSO NAME THE CITY OF ST. PETERSBURG AS ADDITIONAL PARTY TO THE INSURANCE COVERAGE.
5. ALL PROPOSED FACE OF CURB SHALL MATCH THE EXISTING FACE OF CURB, UNLESS OTHERWISE SHOWN ON PLANS.
6. TREES WITHIN THE LIMITS OF THIS PROJECT THAT ARE TO REMAIN SHALL BE TRIMMED TO CONFORM TO SECTION 110, APPLICABLE ADA REQUIREMENTS AND FLORIDA DESIGN MANUAL SECTION 212.11. COST TO BE INCLUDED IN STANDARD CLEARING
AND GRUBBING.
7. ALL DISTURBED AREAS, INCLUDING AREAS OUTSIDE THE CONSTRUCTION LIMITS, SHALL BE RETURNED TO THEIR PRE-CONSTRUCTION CONDITIONS AT THE CONTRACTORS EXPENSE. GRASS AREAS SHALL BE SODDED. NOT SEEDED AND MULCHED.
8. THE CONTRACTOR SHALL PROVIDE AND IMPLEMENT SITE SPECIFIC EROSION AND SEDIMENT CONTROL PROCEDURES SUCH AS SYNTHETIC BALES. STAKED SILT BARRIERS, FLOATING TURBIDITY BARRIER, OR OTHER APPROVED METHODS AS REQUIRED TO PREVENT THE TRANSPORTATION OF SEDIMENT DOWNSTREAM INTO STREETS, STORM DRAINS, DITCHES, PONDS, ETC.
9. ALL EXISTING CITY TRAFFIC SIGNS WITHIN THE PROPOSED CONSTRUCTION LIMITS ARE TO BE PROTECTED BY THE CONTRACTOR.
CAUTION SHOULD BE EXERCISED WHILE RELOCATING EXISTING SIGNS WHERE DIRECTED. IF THE SIGNS ARE DAMAGED BEYOND USE, AS DETERMINED BY THE ENGINEER, THE DAMAGED SIGNS SHALL BE REPLACED AT THE CONTRACTORS EXPENSE.
10. THE CONTRACTOR SHALL COMPLY WITH THE OSHA 20FT RULE; 29 CFR 1926.
11. THE CONTRACTOR SHALL NOTIFY THE PROPERTY OWNERS, 48 HOURS IN ADVANCE OF CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOT RESTRICT ACCESS, DELIVERY, ETC. TO THE PROPERTIES AND SHALL MAINTAIN A SAFE AND DIRECT
ACCESS AT ALL TIMES.
12. ALL FIELD LAYOUT AND SURVEYING FOR CONSTRUCTION OF THIS PROJECT SHALL BE PROVIDED BY THE CONTRACTOR AT HIS
EXPENSE, UNDER THE DIRECTION OF A FLORIDA LICENSED PROFESSIONAL LAND SURVEYOR.
13. THE HORIZONTAL DATUM IS RELATIVE TO THE NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT (NAD83/2011). THE VERTICAL DATUM IS RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88).
14. THE CONTRACTOR SHALL GIVE WRITTEN NOTICE TO ALL AFFECTED CITY WATER CUSTOMERS A MINIMUM OF 24 HOURS IN ADVANCE OF ANY AND ALL WORK REQUIRING DISRUPTION OF ACCESS, INTENDED WATER, OR SANITARY SEWER SERVICE INTERRUPTION. DISRUPTION IN SERVICE TO ANY CUSTOMER SHALL NOT EXCEED 2 HOURS FOR WATER AND 4 HOURS FOR
SANITARY SEWER SERVICE. ACCESS TO PROPERTY SHALL BE MAINTAINED AT ALL TIME.
15. IT SHALL BE RESPONSIBILITY OF THE CONTRACTOR TO SHAPE THE PAVEMENT AT INTERSECTIONS, STREETS, AND DRIVEWAYS SO THAT POSITIVE DRAINAGE WILL BE MAINTAINED WITH NO PONDING OF WATER AS A RESULT OF THE NEW CONSTRUCTION.
16. THE CONTRACTOR SHALL ADJUST (AS REQUIRED) PIPELINE ALIGNMENTS HORIZONTALLY AND/OR VERTICALLY TO AVOID CONFLICTS WITH ACTUAL FIELD CONDITIONS AS UNCOVERED DURING CONSTRUCTION. FIELD ADJUSTMENT SHALL BE
COORDINATED WITH, AND APPROVED BY, THE ENGINEER IN WRITING PRIOR TO REALIGNMENT.
17. THE CONTRACTOR SHALL PROVIDE ALL DEWATERING EQUIPMENT NECESSARY TO KEEP EXCAVATIONS DRY AND SHALL PROVIDE ALL SHORING, SHEETING, AND BRACING NECESSARY TO PROTECT WORKMEN, ADJACENT STRUCTURES, UTILITES, EXISTING PAVEMENT, OR TO MINIMIZE TRENCH WIDTH, AT THE CONTRACTORS EXPENSE.
18. EXISTING SUBSURFACE UTILITY HORIZONTAL ALIGNMENTS WERE ESTABLISHED THROUGH THE USE OF AVAILABLE RECORDS AND THEREFORE, ARE SHOWN IN THERE APPROXIMATE LOCATIONS. THE CONTRACTOR SHALL NOTIFY THE RESPECTIVE UTILITY COMPANIES NO LATER THAN 48 HOURS PRIOR TO COMMENCING WORK IN A SPECIFIC AREA. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE VERIFICATION OF ALL UTILITY LOCATIONS WITHIN THE WORK AREA.
19. ATTENTION IS DIRECTED TO THE FACT THAT SOME PORTIONS OF STORM DRAIN DRAINAGE STRUCTURES OR STORM DRAIN PIPES
EXTEND INTO THE STABILIZED PORTION OF THE ROADWAY. EXTREME CAUTION SHOULD BE UTILIZED DURING STABILIZATION OPERATIONS AT THESE LOCATIONS. ADDITIONAL COMPACTED BASE MATERIAL MAY BE REQUIRED AT THE DIRECTION OF THE
ENGINEER.
20. SEE SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TO GENERAL NOTES
21. CONTRACTOR SHALL NOTIFY OWNER OF ANY DISCREPANCIES BETWEEN NOTES, PLANS, AND/OR SPECS DURING BIDDING.
DISCREPANCIES WILL BE RESOLVED BY THE ENGINEER.
22. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THESE PLANS, THE SPECIFICATIONS, AND CONTRACT DOCUMENTS.
23. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE STARTING WORK, NOTIFY ENGINEER OF
DISCREPANCIES.
24. ALL SAFETY REGULATIONS ARE TO BE STRICTLY FOLLOWED. METHODS OF CONSTRUCTION AND ERECTION OF STRUCTURAL
MATERIAL IS THE CONTRACTORS RESPONSIBILITY.
25. SPECIFIC REQUIREMENTS OF THE CITY OF ST. PETERSBURG CONTRACT SPECIFICATIONS AND STANDARDS ARE INCORPORATED
INTO CONTRACT DOCUMENTS BY REFERENCE.
26. SPECIFIC REQUIREMENTS OF THE FLORIDA DEPARTMENT OF TRANSPORTATION’S ROADWAY AND TRAFFIC DESIGN STANDARDS AND STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION ARE INCORPORATED INTO CONTRACT DOCUMENTS BY
REFERENCE.
27. ALL SPECIFICATION AND DOCUMENTS REFERRED TO SHALL BE OF LATEST REVISIONS AND/OR LATEST EDITION.
28. CONTRACTOR SHALL PROTECT PROPERTY MARKERS, MONUMENTS AND TEMPORARY BENCHMARKS. THE CONTRACTOR’S REGISTERED SURVEYOR SHALL REPLACE TO EXISTING OR BETTER CONDITION ANY DISTURBED PROPERTY MARKERS, MONUMENTS
AND TEMPORARY BENCHMARKS.
29. ANY UNITED STATES COAST AND GEODETIC SURVEY (USC&GS) MONUMENT WITHIN LIMITS OF CONSTRUCTION IS TO BE PROTECTED. IF IN DANGER OF DAMAGE, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY AND CONTACT THE GEODETIC INFORMATION CENTER ATTN.: MARK MAINTENANCE CENTER ATTN: N/CG-162 6001 EXECUTIVE BLVD. ROCKVILLE, MARYLAND 20852 (301) 443-8319.
30. THE CONTRACTOR SHALL MAINTAIN COPIES OF ALL APPLICABLE PERMITS ON-SITE AND SHALL BE RESPONSIBLE TO ADHERE TO ALL
PERMIT CONDITIONS DURING CONSTRUCTION.
31. PAYMENT FOR INCIDENTAL ITEMS NOT SPECIFICALLY LISTED IN THE INDIVIDUAL BID ITEMS SHALL BE INCLUDED IN THE
CONTRACT PRICES FOR BID ITEMS SHOWN.
32. THE CONTRACTOR SHALL PROVIDE, ERECT, AND MAINTAIN BARRICADES, DANGER SIGNALS, AND SIGNS IN ALL AREAS WHERE
REQUIRED FOR THE PROTECTION OF THE WORK AND SAFETY OF THE PUBLIC.
33. ANY DAMAGE TO CITY, COUNTY OR STATE ROADS CAUSED BY THE CONTRACTOR'S HAULING OF EXCAVATION EQUIPMENT OR MATERIALS SHALL BE REPAIRED BY THE CONTRACTOR IN A TIMELY MANNER AND TO THE SATISFACTION OF THE ENGINEER.
PAYMENT SHALL NOT BE MADE FOR THIS WORK.
34. THE CONTRACTOR SHALL ENDEAVOR TO PROTECT PRIVATE PROPERTY. ANY DAMAGE CAUSED BY THE CONTRACTOR IN THE PERFORMANCE OF HIS WORK SHALL BE CORRECTED TO THE SATISFACTION OF THE ENGINEER IN A TIMELY MANNER. PAYMENT
SHALL NOT BE MADE FOR THIS WORK.
35. UPON COMPLETION OF CONCRETE WORK, DEWATERING SHALL BE TERMINATED GRADUALLY TO AVOID RAPID UPWARD MOVEMENT
OF GROUND WATER.
36. MUCK/ORGANIC SOILS ENCOUNTERED DURING EXCAVATION SHALL BE STOCKPILED SEPARATELY AND PROTECTED FROM WEATHER
CONDITIONS FOR USE AS SUBSTRATE IN PLANTING AREAS.
37. THE CONTRACTOR SHALL PLACE CONSTRUCTION DEBRIS CONTROL DEVICES, BOOMS, TARPAULINS, FLOATS, STAGING, AND OTHER DEVICES AS NECESSARY AS TO PREVENT CONSTRUCTION DEBRIS FROM ENTERING THE WATER, AND AIR BORNE MATERIALS FROM LEAVING THE IMMEDIATE VICINITY OF THE SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEAN-UP OF ANY MATERIALS
DEPOSITED OUTSIDE THE WORK AREA.
38. CONTRACTOR SHALL CONFORM TO THE CITY OF ST. PETERSBURG NOISE CODE.
39. PIPE LENGTHS SHOWN ARE APPROXIMATE. LOCATIONS OF STRUCTURES SHALL GOVERN AND PIPE LENGTHS SHALL BE ADJUSTED
ACCORDINGLY.
40. THE CONTRACTOR(S) PERFORMING TRENCH EXCAVATION ON THIS CONTRACT, IN EXCESS OF (5) FIVE FEET IN DEPTH, SHALL COMPLY WITH THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION'S (OSHA) TRENCH EXCAVATION SAFETY STANDARDS, 29 C.F.R., S1926.650, SUBPART P, INCLUDING ALL SUBSEQUENT REVISIONS OR UPDATES TO THE STANDARDS AS ADOPTED BY THE
DEPARTMENT OF LABOR AND EMPLOYMENT SECURITY (DLES).
41. CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL TRAFFIC. EXCAVATION SHALL BE LIMITED TO THE AMOUNT OF STORMWATER, POTABLE WATER, SANITARY SEWER PIPE OR ANY OTHER SUBSURFACE UTILITY TO BE INSTALLED WITHIN THE SAME WORKING DAY.
TRENCHES SHALL BE BACKFILLED IN THE SAME DAY.
42. CONTRACTOR SHALL MAINTAIN AS-BUILT DRAWINGS IN GOOD ORDER AND LEGIBLE CONDITION TO BE CONTINUOUSLY MARKED UP AT THE JOB SITE. AS-BUILT DRAWINGS SHALL BE AVAILABLE FOR INSPECTION BY THE ENGINEER AT ALL TIMES DURING THE PROGRESS OF THE PROJECT. AS-BUILT DRAWINGS SHALL BE REVIEWED BY THE CITY INSPECTOR FOR ACCURACY AND COMPLIANCE
PRIOR TO SUBMITTAL OF MONTHLY PAY REQUESTS.
TRAFFIC CONTROL NOTES
1. THE TRAFFIC IS TO BE MAINTAINED IN THE URBAN SECTION OF THE PROJECT IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FY 2023-24 FDOT STANDARD DESIGN INDICES 102-600 THRU 102-680. ADVISORY SPEED PLATES AND REDUCED SPEED AHEAD SIGNS ARE TO BE USED IN CONJUNCTION WITH THE SIGNING SCHEMES SHOWN ON THE ABOVE INDEXES IN ACCORDANCE
WITH THE INDEX NO. 102-600.
2. ALL EXISTING STREET SIGNS THAT ARE AFFECTED BY THE PROJECT SHALL BE RELOCATED AND MAINTAINED BY THE CONTRACTOR
AT ALL TIMES FOR THE DURATION OF THE PROJECT.
3. THE CONTRACTOR SHALL NOTIFY THE FOLLOWING:
FIRE DEPARTMENT (727) 893-7526
SUN STAR EMERGENCY CENTER DISPATCH (727) 582-2073
ST. PETERSBURG POLICE DISPATCH CENTER (727) 893-7780
PSTA TRANSPORTATION DEPARTMENT (727) 530-9921
PINELLAS COUNTY (727) 464-3251
NO LESS THAN 48 HOURS IN ADVANCE OF ANTICIPATED DISRUPTION TO THE NORMAL FLOW OF TRAFFIC, INCLUDING LANE
CLOSURES, DETOURS AND SIGNAL WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO CURB AND/OR GUTTER, SIDEWALK, ETC. DURING ALL CONSTRUCTION
ACTIVITIES
5. ALL TEMPORARY SIGNS, PAVEMENT MARKINGS, BARRICADES, WARNING LIGHTS, ETC. NECESSARY FOR THE MAINTENANCE OF TRAFFIC SHALL CONFORM TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (LATEST EDITION) AND THE FDOT DESIGN
STANDARDS (2023-24)
6. THE CONTRACTOR SHALL KEEP THE ROADWAY OPEN AT NIGHT.
PEDESTRIAN NOTES
1. EXISTING
SIDEWALK
ADJACENT
TO
THE
PROPOSED
SHALL
BE
SAW
CUT.
COST
OF
SAW
CUTTING
INCIDENTAL TO THE WORK BEING PERFORMED.
2. CONSTRUCTION
STAGING
NOT
TAKE
PLACE
IN
NOR
INTERFERE
WITH
ACCESS
OR
ACTIVITIES.
3. THE CONTRACTOR SHALL NOT STAGE OR STORE MATERIAL OR EQUIPMENT ON THE SIDEWALK.
4. NO CLOSURE OF THE SIDEWALK SHALL BE ALLOWED.
5. PEDESTRIAN
TRAFFIC
IS
MAINTAINED
AT
ALL
TIMES
DURING
CONSTRUCTION
PROCESS.
CONTRACTOR
RESPONSIBLE
FOR
ENSURING
THAT
SAFE,
UNOBSTRUCTED
ROUTE
EXISTS
PEDESTRIANS,
PER
FDOT
STANDARD
INDEX
NO.
102-660
NOTES FOR STORM STRUCTURES
1. ALL
PIPE
STUBS
FROM
STRUCTURES
FUTURE
CONNECTIONS,
INSTALLED
REMOVABLE
WATERTIGHT
PLUGS,
PLACED FROM WITHIN THE STRUCTURE.
2. FOR APPLICABLE RING AND COVER, SEE STANDARD DETAIL-MANHOLE RING AND COVER CASTING.
3. STORM STRUCTURES SHALL NOT HAVE OUTSIDE DROP CONNECTIONS.
4. PROVIDE
MINIMUM
8"
SOLID
WALL
BETWEEN
OPENINGS
PIPES.
SEAL
BETWEEN
AND
STRUCTURE
NON
SHRINK
GROUT.
5. ALL BRICK SHALL BE CONCRETE OR CLAY BRICK AND SHALL HAVE A MINIMUM 3/4" CEMENT PLASTER COATING ON ALL SURFACES.
6. BENCH SHALL SLOPE @ 1:12 MINIMUM.
7. PRECAST
CAST-IN-PLACE
MANHOLES,
CATCH
BASINS,
GRATE
INLETS
ARE
DESIGNED
MAXIMUM
DEPTH
FEET,
EXCESS
FEET,
AS
MEASURED
FINISHED
GRADE
INSIDE
BASE
SLAB,
REQUIRE
VERIFICATION
STRUCTURAL
DESIGN
SPECIFIC
MODIFICATIONS
REINFORCING
REQUIREMENTS
THE DEPTH REQUIRED.
8. PRIOR
PRECASTING
PRECASTER
SUBMIT
SITE
SPECIFIC
INDIVIDUAL
SHOP
DRAWINGS
APPROVAL.
SHOP
DRAWINGS
SUBMITTED
NON-STANDARD
THAT
DEVIATE
STANDARD
DETAILS
MUST BE DESIGNED AND CERTIFIED BY A REGISTERED FLORIDA PROFESSIONAL ENGINEER.
9. PRECAST MANHOLES SHALL CONSIST OF A LIMITED NUMBER OF SECTIONS, AS APPROVED BY THE ENGINEER.
10. ALL PRECAST STRUCTURES SHALL HAVE AN INTEGRAL FLOOR AND BASE RISER SECTION.
11. SEE STANDARD DETAIL-PRECAST STRUCTURE JOINT ASSEMBLY AND STRUCTURE SEALING.
12. ALL EXPOSED EDGES TO HAVE 3/4" CHAMFER.
13. ALL REINFORCING STEEL SHALL HAVE A MINIMUM 2" CONCRETE COVER, UNLESS NOTED ELSEWHERE.
14. ADDITIONAL
REINFORCEMENT
REQUIRED
TYPE
CATCH
BASIN
WALLS,
GRATE
INLETS,
II,
III,
IV,
V
MANHOLE
WALLS
CULVERT.
VERTICAL
HORIZONTAL
WALL
DISPLACED
DUE
REPLACED
ADDITIONAL
BARS
ABOVE,
BELOW,
ON
BOTH
SIDES
OPENING,
EQUAL
AREA
THOSE
DISPLACED.
REPLACEMENT
PLACED
3"
CLEARANCE
EDGES
OPENINGS.
NOTES FOR SANITARY STRUCTURES
1. ALL
MANHOLES
BRICK,
PRECAST
CONCRETE
FIBERGLASS
REINFORCED
POLYESTER
(FRP),
UNLESS
OTHERWISE
SHOWN
OR APPROVED BY THE ENGINEER.
2. ALL
STUBS
MANHOLES,
FUTURE
CONNECTIONS,
INSTALLED
REMOVABLE
WATERTIGHT
PLUGS,
PLACED FROM WITHIN THE MANHOLE.
3. ALL
I
CONE
SECTIONS
CONCENTRIC
RING
CASTING
CENTERED
STRUCTURE,
UNLESS
OTHERWISE
SHOWN
OR DIRECTED BY THE ENGINEER.
4. THE CONE SECTION OF TYPE I PRECAST MANHOLE SHALL BE PRECAST.
7. 7 DAYS ADVANCE NOTICE TO MOTORING PUBLIC REQUIRED FOR ALL ROAD CLOSURES AND DETOURS.
NOTES FOR SANITARY STRUCTURES (CONT.)
5. NO PIPE SHALL BE IN THE MANHOLE CONE SECTION.
6. ALL MANHOLES WITH SLAB TOP SHALL BE TYPE II, SEE STANDARD DETAIL-TYPE II MANHOLE TOP SLAB.
7. A DROP MANHOLE SHALL BE REQUIRED WHEN THE INVERT OF ANY INCOMING PIPE IS 24" OR MORE ABOVE THE INVERT OF THE
MANHOLE. ALL DROP PIPE SHALL BE ON THE OUTSIDE OF THE MANHOLE.
8. PRIOR TO MANUFACTURING STRUCTURES THE MANUFACTURER SHALL SUBMIT SITE SPECIFIC INDIVIDUAL SHOP DRAWINGS FOR APPROVAL. SHOP DRAWINGS SUBMITTED FOR NONSTANDARD STRUCTURES OR STRUCTURES THAT DEVIATE FROM THE STANDARD DETAILS MUST BE DESIGNED AND CERTIFIED BY A REGISTERED FLORIDA PROFESSIONAL ENGINEER.
9. PRECAST MANHOLES SHALL CONSIST OF A MINIMUM NUMBER OF SECTIONS, AS APPROVED BY THE ENGINEER.
10. ALL PRECAST STRUCTURES SHALL HAVE AN INTEGRAL FLOOR AND BASE RISER SECTION, SEE STANDARD DETAIL-TYPE I AND II
MANHOLE BASE AND WALL.
11. SEE STANDARD DETAIL-PRECAST STRUCTURE JOINT ASSEMBLY AND STRUCTURE SEALING.
12. ALL EXPOSED EDGES TO HAVE A 3/4" CHAMFER.
13. FOR THE APPLICABLE RING AND COVER, SEE STANDARD DETAIL-MANHOLE RING AND COVER CASTING.
14. PRECAST BASE SECTION SHALL BE INSTALLED ON A CONCRETE MAT WITHIN 2 HOURS OF PLACEMENT OF THE MAT.
15. ALL BRICK SHALL BE CLAY BRICK AND SHALL HAVE A MINIMUM 3/4" CEMENT PLASTER ON ALL SURFACES.
16. BENCH SHALL SLOPE @ 1:12 MINIMUM.
17. PRIOR TO MANUFACTURING OF FRP MANHOLE, MANUFACTURER SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS FOR THE DESIGN OF INVERT AND BENCH AREA, PIPE CONNECTIONS, FABRICATION DETAILS AND INSTALLATION METHODS FOR APPROVAL.
18. ADDITIONAL REINFORCEMENT IS REQUIRED IN ALL TYPE II MANHOLE WALLS WITH OPENINGS FOR PIPES. THE VERTICAL AND HORIZONTAL WALL REINFORCEMENT DISPLACED DUE TO OPENINGS SHALL BE REPLACED WITH ADDITIONAL REINFORCEMENT BARS ABOVE, BELOW, AND ON BOTH SIDES OF OPENINGS, EQUAL IN AREA TO THOSE DISPLACED. REPLACEMENT REINFORCEMENT
SHALL BE PLACED WITH 3" CLEARANCE TO THE EDGES OF OPENINGS.
19. FRP MANHOLE INVERT AND BENCH SHALL BE CONCRETE.
20. FRP STIFFENING RIBS ARE REQUIRED AT 10' DEPTH OR MORE.
21. THE CONTRACTOR SHALL NOTIFY THE RESPECTIVE PROPERTY OWNERS A MINIMUM OF 48 HOURS IN ADVANCE OF ANY AND ALL DISRUPTIONS TO SANITARY SEWER SERVICE. DISRUPTION IN SERVICE TO ANY RESIDENCE SHALL NOT EXCEED FOUR (4) HOURS, AND SHALL ONLY BE OUT OF SERVICE DURING WORKING HOURS. DISRUPTION IN SERVICE TO ANY BUSINESS SHALL BE
COORDINATED WITH BUSINESS OWNER AND THE CITY.
22. CONTRACTOR TO PROVIDE PUMP-AROUND FOR ANY SANITARY SEWER MODIFICATION TO KEEP SANITARY SEWER IN OPERATION
AT ALL TIMES.
NOTES FOR PRESSURE PIPE
1. ALL PRESSURE PIPE MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO THE SPECIFICATIONS AND DETAILS AS
SHOWN HEREIN, OR AS DIRECTED BY THE ENGINEER.
2. PIPE JOINT DEFLECTION SHALL NOT EXCEED 75% OF THE PIPE MANUFACTURE REQUIREMENTS.
3. THE CONTRACTOR SHALL ADJUST PIPELINE ALIGNMENTS HORIZONTALLY AND/OR VERTICALLY AS REQUIRED TO AVOID CONFLICTS WITH ACTUAL FIELD CONDITIONS AS UNCOVERED DURING CONSTRUCTION. FIELD ADJUSTMENTS SHALL BE COORDINATED WITH
AND APPROVED BY THE ENGINEER.
4. PRESSURE PIPE CLEARANCES SHALL BE AS FOLLOWS:
A) POTABLE WATER MAINS IN PARALLEL INSTALLATIONS SHALL MAINTAIN A MINIMUM 6 FEET AN PREFERABLY 10 FEET
OUTSIDE TO OUTSIDE HORIZONTAL CLEARANCE FROM ALL WASTEWATER GRAVITY MAINS, STORM DRAINS, AND
WASTEWATER FORCE MAINS.
B) POTABLE WATER MAINS WHERE CROSSING SHALL MAINTAIN A MINIMUM OF 12 INCHES AND PREFERABLY 18 INCHES OUTSIDE TO OUTSIDE VERTICAL CLEARANCE ABOVE ALL WASTEWATER GRAVITY MAINS, STORM DRAINS, AND WASTEWATER
FORCE MAINS.
C) POTABLE WATER MAINS SHALL MAINTAIN A MINIMUM OF 5 FOOT CENTER TO CENTER HORIZONTAL CLEARANCE OR 3 FOOT OUTSIDE TO OUTSIDE HORIZONTAL CLEARANCE, AND A MINIMUM OF 12 INCHES AND PREFERABLY 18 INCHES OUTSIDE TO
OUTSIDE VERTICAL CLEARANCE FROM RECLAIMED WATER MAINS.
D) RECLAIMED WATER MAINS SHALL MAINTAIN A MINIMUM OF 5 FOOT CENTER TO CENTER HORIZONTAL CLEARANCE OR 3 FOOT OUTSIDE TO OUTSIDE HORIZONTAL CLEARANCE, AND A MINIMUM OF 12 INCHES AND PREFERABLY 18 INCHES
OUTSIDE TO OUTSIDE VERTICAL CLEARANCE FROM WASTEWATER FORCE MAINS.
E) FULL LENGTH WASTEWATER FORCE MAIN PIPE SHALL BE CENTERED AT POTABLE WATER MAIN CROSSINGS SO THAT THE
WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE FORCE MAIN JOINTS.
5. THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER REGARDING SHUTTING DOWN WATER MAINS. PROPER AND ADEQUATE NOTIFICATION MUST BE MADE TO PROPERTY OWNERS, BUT IN NO CASE SHALL LESS THAN 24 HOURS WRITTEN NOTICE
BE GIVEN.
6. THE OPENING AND/OR CLOSING OF EXISTING VALVES OR NEW VALVES INSTALLED IN PRESSURE PIPE SYSTEMS SHALL BE BY A
CITY SANITARIAN AFTER COORDINATION WITH THE ENGINEER.
7. THE CONTRACTOR SHALL PROVIDE NECESSARY EQUIPMENT AND LABOR TO MAKE TAPS IN PRESSURE PIPE MAINS WHERE TAPPING
SLEEVES AND VALVES ARE SHOWN ON THE PLANS.
8. ALL NEW DUCTILE IRON PRESSURE PIPE, FITTINGS, AND VALVE BODIES SHALL BE WRAPPED IN POLYETHYLENE IN ACCORDANCE
WITH ANSI/AWWA C105.
9. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE AND PROTECT ALL EXISTING POTABLE AND RECLAIMED SERVICE LINES UNDER PAVEMENT OR ELSEWHERE IN THE CONSTRUCTION ZONE. REPLACE SERVICE LINES WHERE SHOWN OR DIRECTED BY THE ENGINEER. ALL RELOCATED SERVICE LINES SHALL BE RELOCATED SO THAT THE METER ASSEMBLY WILL NOT BE IN AN ALLEY, DRIVEWAY, OR OTHER VEHICULAR TRAVEL PATH.
10. ALL EXISTING POTABLE AND/OR RECLAIMED WATER SERVICE LINES SHALL BE TRANSFERRED TO THE NEW MAIN, UNLESS
OTHERWISE DIRECTED BY THE ENGINEER.
11. MAINTAIN A MINIMUM COVER OF 36 INCHES UNDER ROADWAYS, ALLEYS, AND DRIVEWAYS. MAINTAIN A MINIMUM OF 30 INCHES
OF COVER IN SODDED AND LANDSCAPED AREAS.
12. THRUST BLOCKING SHALL NOT BE USED, UNLESS ORDERED BY THE ENGINEER. RESTRAINED PIPE JOINTS SHALL BE USED. THE
LENGTH OF RESTRAINED JOINTS SHALL BE AS SHOWN ON THE PLANS.
13. SANITARY SEWER FORCE MAINS SHALL NOT USE GREATER THAN 45° BENDS FOR OFFSETS OR REALIGNMENT OF THE FORCE MAIN.
THE 45° BENDS SHALL HAVE A MINIMUM OF 5 FEET BETWEEN THEM, WHEN POSSIBLE.
MANHOLE NOTES
1. PRECAST MANHOLE SECTIONS SHALL BE MANUFACTURED IN ACCORDANCE WITH LATEST EDITIONS OF ASTM C-478 WITH 4000
P.S.I. TYPE II CEMENT.
2. PRECAST CONCRETE MANHOLE BASES SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4000 P.S.I. AND SHALL
UTILIZE TYPE II CEMENT.
3. CONCRETE PLACED IN MANHOLE INVERTS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 4000 P.S.I. AND SHALL
UTILIZE TYPE II CEMENT.
4. LIFT HOLES THROUGH PRECAST STRUCTURES ARE NOT PERMITTED.
5. ALL PIPE PENETRATIONS SHALL BE PRECAST OR CORE-DRILLED. THE PERIMETER OF PENETRATION SHALL NOT BE CLOSER THAN
12” TO A BARREL SECTION JOINT.
6. RUBBER BOOT TO BE USED AT ALL PIPE PENETRATIONS.
7. JOINT CONTACT SEALS SHALL BE PLACED AT ALL RISER JOINTS, ½” THICK WITH WIDTH AT LEAST ½ THE WALL THICKNESS.
8. THE INTERIOR OF THE ADJUSTMENT SECTION SHALL BE PLASTERED WITH ¾” ACID RESISTANT. MORTAR WHEN BRICK
ADJUSTMENT RING IS USED. OTHER APPROVED EQUAL CONSTRUCTION MAY BE CONSIDERED.
9. MANHOLE COVER SHALL BE WATERTIGHT OR EQUIPPED WITH AN INFLOW PROTECTOR IN SODDED AREAS.
10. BOTTOM BARREL AND BASE OF MANHOLE TO BE MONOLITHICALLY OR INTEGRALLY CAST.
11. SERVICE LATERALS TO MANHOLES SHALL BE TREATED AS MAINS (CORE DRILLED FOR PENETRATION AND FLOW CHANNEL SHALL BE
CONSTRUCTED).
12. PRECAST OR CORE-DRILLED PENETRATION DIAMETERS SHALL BE PER MANUFACTURER SPECIFICATIONS OR AS FOLLOWS:
a. 6” TO 8” FOR 4” DIAMETER PIPE
b. 10 TO 12” FOR 8“ DIAMETER PIPE
c. 16” FOR 12” DIAMETER PIPE
13. MATERIALS OF CONSTRUCTION, PLACEMENT, AND COMPACTION REQUIREMENTS FOR BEDDING MATERIALS SHALL MEET CITY OF
ST. PETERSBURG AND PINELLAS COUNTY SPECIFICATIONS.
14. FLOW CHANNELS SHALL BE CONSTRUCTED TO DIRECT INFLUENT INTO THE FLOW STREAM.
15. PROPERLY SHAPED SPILLWAYS SHALL BE CONSTRUCTED BETWEEN PIPES WITH DIFFERENT INVERT ELEVATIONS TO PROVIDE FOR
SMOOTH FLOWS.
UTILITIES NOTES
1. PRIVATE UTILITIES THAT ARE IN CONFLICT WITH THE PROPOSED CONSTRUCTION HEREIN SHALL BE RELOCATED BY THE UTILITY OWNER. UNLESS OTHERWISE NOTED IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL COORDINATE THE SCHEDULE OF
RELOCATION TO ENSURE IT IS PERFORMED IN A TIMELY MANNER.
2. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTING POINTS (BEGINNING AND END), (LOCATION AND INVERTS) FOR UTILITIES PRIOR TO STARTING CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ENGINEER OF ANY DISCREPANCIES.
3. INFORMATION SHOWN ON THESE DRAWINGS AS TO THE LOCATION OF EXISTING UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE DATA AVAILABLE TO THE ENGINEER. HOWEVER, IT IS NOT GUARANTEED. THE CONTRACTOR SHALL NOTIFY THE APPROPRIATE UTILITY COMPANY AND CALL THE STATE OF FLORIDA 811 NOTIFICATION CENTER AT 811, A MINIMUM OF 48 HOURS PRIOR TO EXCAVATION. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCATION, CHARACTER AND DEPTH OF
ANY EXISTING UTILITIES.
4. UNLESS WRITTEN APPROVAL FROM THE ENGINEER IS PROVIDED, THE LOWEST PIPE SHALL BE INSTALLED FIRST WHEN UTILITIES
CROSS.
5. SANITARY SEWER GRAVITY LINES SHALL BE CONSTRUCTED OF PVC MATERIAL MEETING THE GENERAL SPECIFICATIONS OF ASTM
D3034, SDR 26.
6. WASTEWATER GRAVITY SEWERS SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED POTABLE
WATER MAIN.
7. A THREE FOOT HORIZONTAL SEPARATION SHALL BE MAINTAINED BETWEEN A WASTEWATER GRAVITY/FORCE MAIN AND ALL
OTHER PIPELINE. THE DISTANCE SHALL BE MEASURED FACE TO FACE.
8. VERTICAL SEPARATION BETWEEN WASTEWATER SEWER MAINS CROSSING POTABLE WATER MAINS, RECLAIMED WATER MAINS, OR STORMWATER LINES SHALL BE MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE OUTSIDE SEPARATION OF THE LINES.
9. GRAVITY SEWER PIPE AND FITTINGS SHALL BE MADE OF PVC MATERIAL HAVING A CELL CLASSIFICATION OF 1254B, 12454 C OR 13354 B AS DEFINED IN ASTM D1784. SDR 26 PVC PIPE AND FITTINGS SHALL BE USED IN THE GRAVITY SEWER SYSTEM AND SHALL
MEET REQUIREMENTS OF ASTM D3034.
10. MORTAR FOR PIPE, MANHOLE ADJUSTMENT RINGS AND BRICK JOINTS SHALL BE COMPOSED OF PORTLAND CEMENT AND SAND, CONFORMING TO ASTM C270
A) MORTAR SHALL CONSIST OF ONE PART PORTLAND CEMENT TYPE II CONFORMING TO ASTM C150, AND TWO (2) PARTS BY
VOLUME OF WASHED SILICA MORTAR SAND CONFORMING TO ASTM C144
B) LIME SHALL NOT BE USED.
11. NO PIPE SHALL BE LAID WHEN TRENCH CONDITIONS OR THE WEATHER IS UNSUITABLE FOR SUCH WORK.
12. MANHOLE BASE SECTIONS SHALL BE SET IN THE LEVELING COURSE OF CRUSHED STONE SUBBASE COMPACTED TO NOT LESS THAN 98% OF MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST ASTM D1557.
13. THE TRENCH BACKFILL DENSITY FOR ALL STAGES SHALL BE COMPACTED TO 98% OF THE MAXIMUM DENSITY AS DETERMINED BY AASHTO T-180 (ASTM D1557 – MODIFIED PROCTOR) WITH A MINIMUM 2% TOLERANCE. THERE SHALL BE MINIMUM OF ONE TEST
BETWEEN STRUCTURES AND NOT TO EXCEED 500 FEET HORIZONTALLY.
14. ELECTRONICALLY DETECTABLE TAPE SHALL BE INSTALLED IN TRENCHES ABOVE ALL PVC PIPING APPROXIMATELY 18 INCHES
ABOVE THE PIPE.
15. CUTS FOR UTILITY REPLACEMENT OR RELOCATION SHALL BE RESTORED AS SOON AS THE REPLACEMENT OR RELOCATION IS
COMPLETED.
16. PIPE LENGTHS SHOWN ARE APPROXIMATE. LOCATIONS OF STRUCTURES SHALL GOVERN AND PIPE LENGTHS SHALL BE ADJUSTED
ACCORDINGLY.
17. IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL COORDINATE THE SCHEDULE OF RELOCATION TO ENSURE IT IS PERFORMED
IN A TIMELY MANNER.
18. THE POLYETHYLENE TUBING FOR THE HOSE BIB SHALL BE SDR-9 200 PSI.
19. THREE INCH AND SMALLER HDPE TUBING SHALL BE PERFORMANCE PIPES “DRISCOPLEX”, ENDOT “ENDOPURE”, VANGUARD
“BRUISER”, OR APPROVED EQUAL.
20. THE CONTRACTOR SHALL ENSURE THAT ALL DRAINAGE STRUCTURES, PIPES, ETC. ARE CLEAN AND FUNCTIONING PROPERLY AT
THE TIME OF ACCEPTANCE.
SEDIMENTATION AND EROSION CONTROL NOTES
1. ALL SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE AND
MAINTAINED THROUGH PROJECT COMPLETION.
2. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION WILL BE MINIMIZED. ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS SHALL BE COMPLIED WITH AT ALL TIMES.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EROSION AND WATER POLLUTION RESTORATION EFFORTS.
4. ALL EROSION AND SEDIMENT CONTROL MEASURES INDICATED ON THESE DRAWINGS ARE FOR START-UP AND REFERENCE.
LOCATIONS MAY BE MODIFIED IN THE FIELD PER THE ENGINEER’S APPROVAL.
5. CONTRACTOR SHALL MAINTAIN SEDIMENT AND EROSION CONTROL MEASURES IN ACCORDANCE WITH THE CITY OF ST.
PETERSBURG AND THE SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD).
6. CONTRACTOR SHALL PROVIDE DUST CONTROL AND PROTECT ADJACENT PROPERTIES FROM THE ACCUMULATION OF SOIL, DEBRIS
AND GARBAGE.
7. PRIOR TO START OF CONSTRUCTION, THE CONTRACTOR SHALL PREPARE A "STORMWATER POLLUTION PREVENTION PLAN" (SPPP) FOR THE OWNER'S APPROVAL AND SUBMIT THE SPPP ALONG WITH A NOTICE OF INTENT FDEP FORM 62-621.300(4)(B) TO THE
NPDES STORMWATER NOTICES CENTER.
GENERAL LANDSCAPING NOTES
1. ALL PLANT MATERIALS TO BE FLORIDA #1 OR BETTER QUALITY, INSTALLED TO HIGHEST NURSERY STANDARDS.
2. MULCH TO BE RECYCLED WOOD MULCH, UNLESS OTHERWISE SPECIFIED. MULCH SHALL BE INSTALLED TO A MINIMUM OF 3" THICK
IN ALL PLANTING AREAS.
3. SOD TO BE 95% WEED FREE: ARGENTINE BAHIA OR ST. AUGUSTINE "FLORATAM", AS SPECIFIED ON THE PLANS. SOD TO BE INSTALLED WITH TIGHT JOINTS, ROLLED AND FERTILIZED AT TIME OF INSTALLATION. ALL AREAS DISTURBED DURING PLANT REMOVAL AND/OR PLANTING WORK SHALL BE FILLED AND GRADED TO MATCH THE ADJACENT GRADE AND SODDED AS REQUIRED TO COVER ANY EXPOSED GROUND. SODDED AREAS SHALL BE INCLUDED IN THE ESTABLISHED WATERING PERIOD.
4. ALL DIMENSIONS TO BE FIELD CHECKED BY THE LANDSCAPE CONTRACTOR PRIOR TO CONSTRUCTION, WITH ANY DISCREPANCIES
REPORTED IMMEDIATELY TO THE ENGINEER.
5. ALL MATERIALS MUST BE AS SPECIFIED ON THE LANDSCAPE PLAN. IF MATERIALS OR LABOR DO NOT ADHERE TO THE SPECIFICATIONS, THEY WILL BE REJECTED BY THE ENGINEER WITH PROPER INSTALLATION CARRIED OUT BY THE CONTRACTOR
AT NO ADDITIONAL COST TO THE CITY.
6. NO SUBSTITUTIONS OR CHANGES OF ANY KIND WILL BE MADE AT THE TIME OF BIDDING, SO AS TO PROVIDE FOR EQUAL AND
FAIR BID COMPARISONS.
7. ALL PERMITS NECESSARY ARE TO BE OBTAINED BY THE INSTALLING CONTRACTOR, UNLESS OTHERWISE SPECIFICALLY STATED IN
THE SPECIFICATIONS.
8. NO CONTRACTOR IDENTIFICATION SIGNS SHALL BE PERMITTED ON THE PROJECT.
9. CAREFULLY REVIEW THE LANDSCAPE SPECIFICATIONS. THE INSTALLATION CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL
ITEMS CONTAINED THEREIN.
10. ALL PLANT MATERIALS SHALL HAVE A ONE YEAR WARRANTY UNLESS OTHERWISE SPECIFIED IN THE CONTRACT DOCUMENTS.
ENVIRONMENTAL NOTES
1. THE CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS TO THE PINELLAS COUNTY AND CITY OF ST. PETERSBURG
LANDSCAPING AND TREE ORDINANCES AND THE SITE CLEARING AND ALTERATION ORDINANCES.
2. SPECIAL CARE IS TO BE TAKEN SO TREES TO BE PRESERVED REMAIN UNHARMED DURING CONSTRUCTION.
W
25"
12"
20"
12"
12"
SIGN:
NO PARKING
STOP
SIGN
SIGN:
NO PARKING
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
W
W
W
6" V
ER
TI
C
AL
C U
R B
6" V
ER
TI
C
AL
C U
R B
5681 5683
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
AP
PA
R
EN
T
R
IG
H T-
O F-
W
AY
C O
N C
R
ET
E
SI
D
EW
AL
K
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
12" R C
P
" R
C P
6" UNK
12" RCP
D-1
SIGN:
COMMUNITY
CENTER
SIGN:
PED CROSSING
8" RCP
D-2
D-3
72 4'
CLF
6' C
LF
5 5
5.99 5.23
5.
5.
5.695.24 5.545.14
5.595.18
5.344.98
5.384.90
5.475.23
5.315.00
5.
4.
695.
4.
5.12 4.82
5.174.69
5.35 4.764.91
4.62
5.154.88
5.194.96
5.515.09
5.14 4.98
5.3
5.1
BARTLETT PARK
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
STOP
SIGN
CITY OF ST.PETERSBURG
(NO DEED AVAILABLE)
5.094.96
4.73 4.68
4.86
5.0
4.9
SIGN:
NO PARKING
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
SIGN:
NO PARKING
VVH104
VVH103
VVH
VVH104
VVH103
W
25"
12"
20"
12"
12"
SIGN:
NO PARKING
STOP
SIGN
SIGN:
NO PARKING
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
W
W
W
6" V
ER
TI
C
AL
C U
R B
6" V
ER
TI
C
AL
C U
R B
5681 5683
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
AP
PA
R
EN
T
R
IG
H T-
O F-
W
AY
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
AP
PA
R
EN
T
R
IG
H T-
O F-
W
AY
C O
N C
R
ET
E
SI
D
EW
AL
K
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
12" R C
P
" R
C P
6" UNK
12" RCP
D-1
SIGN:
COMMUNITY
CENTER
SIGN:
PED CROSSING
8" RCP
D-2
D-3
72 4'
CLF
6' C
LF
5 5
5.99 5.23
5.
5.
5.695.24 5.545.14
5.595.18
5.344.98
5.384.90
5.475.23
5.315.00
5.
4.
695.
4.
5.12 4.82
5.174.69
5.35 4.764.91
4.62
5.154.88
5.194.96
5.515.09
5.14 4.98
5.3
5.1
BARTLETT PARK
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
STOP
SIGN
CITY OF ST.PETERSBURG
(NO DEED AVAILABLE)
5.094.96
4.73 4.68
4.86
5.0
4.9
SIGN:
NO PARKING
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
SIGN:
NO PARKING
VVH
VVH104
VVH103
W
25"
12"
20"
12"
12"
SIGN:
NO PARKING
STOP
SIGN
SIGN:
NO PARKING
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
6" VERTICAL CURB
W
W
W
6" V
ER
TI
C
AL
C U
R B
6" V
ER
TI
C
AL
C U
R B
5681 5683
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
AP
PA
R
EN
T
R
IG
H T-
O F-
W
AY
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
AP
PA
R
EN
T
R
IG
H T-
O F-
W
AY
C O
N C
R
ET
E
SI
D
EW
AL
K
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
12" R C
P
" R
C P
6" UNK
12" RCP
D-1
SIGN:
COMMUNITY
CENTER
SIGN:
PED CROSSING
8" RCP
D-2
D-3
72 4'
CLF
6' C
LF
5 5
5.99 5.23
5.
5.
5.695.24 5.545.14
5.595.18
5.344.98
5.384.90
5.475.23
5.315.00
5.
4.
695.
4.
5.12 4.82
5.174.69
5.35 4.764.91
4.62
5.154.88
5.194.96
5.515.09
5.14 4.98
5.3
5.1
BARTLETT PARK
AP
PA
R
EN
T R
IG
H
T- O
F- W
AY
STOP
SIGN
CITY OF ST.PETERSBURG
(NO DEED AVAILABLE)
5.094.96
4.73 4.68
4.86
5.0
4.9
SIGN:
NO PARKING
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
SIGN:
NO PARKING
VVH104
PPAPPAPAA
8"
W
W
" 1
3"
"12
"1 5"
TV
R C
W
W
W
W
" 10
G
SIG
N
SPEED
LIM
IT
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-WAY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
APPARENT RIGHT-OF-WAY
SIG
N
BU
S STO
P
VAU
LT
VAULT
D-3
D-1
D -2
STO
P SIG
N
3 3 3
3 3
3 101
142514
23"x14" ER C
P
18" RCP
10" STEEL
10" STEEL
6" CLAY
15" RCP
C O
N C
R
ETE D
R
IVEW
AY
3' C
LF
3.87 2.97
3.26 2.85
3.393.04
3.39 3.04
3.292.86
3.23 2.97
3.37 3.05
3.13 2.82
3.49 3.19
3.403.05
3.363.03
3.332.99
3.32 3.023.28 2.99
3.322.99
3.132.94
3.202.88
3.132.87
3.10 2.85
2' CURB & GUTTER2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER 2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
3.24 2.76
2.682.6514
2.81
6" C
LAY
8"
W
W
" 1
3"
"12
"1 5"
TV
R C
W
W
W
W
" 10
G
SIG
N
SPEED
LIM
IT
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-WAY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
APPARENT RIGHT-OF-WAY
SIG
N
BU
S STO
P
VAU
LT
VAULT
D-3
D-1
D -2
STO
P SIG
N
3 3 3
3 3
3 101
142514
23"x14" ER C
P
18" RCP
10" STEEL
10" STEEL
6" CLAY
15" RCP
C O
N C
R
ETE D
R
IVEW
AY
3' C
LF
3.87 2.97
3.26 2.85
3.393.04
3.39 3.04
3.292.86
3.23 2.97
3.37 3.05
3.13 2.82
3.49 3.19
3.403.05
3.363.03
3.332.99
3.32 3.023.28 2.99
3.322.99
3.132.94
3.202.88
3.132.87
3.10 2.85
2' CURB & GUTTER2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER 2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
3.24 2.76
2.682.6514
2.81
6" C
LAY
" 1
3"
"12
"1 5"
TV
R C
W
SIG
N
SPEED
LIM
IT
APPAR
EN
T R
IG
H T-O
F-W
AY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
VAU
LT
VAULT
D-1
D -2
3 3 3
23"x14" ER C
P
18" RCP
15" RCP
C O
N C
R
ETE D
R
IVEW
AY
3.23 2.97
3.37 3.05
3.13 2.82
3.49 3.19
3.403.05
3.332.99
3.22.88
3.132.87
3.10 2.85
2' CURB & GUTTER
2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
3.24 2.76
2.682.6514
6" C
LAY
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
VAU
VAU
VA
8"
W
W
W
W
" 10
G
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-WAY
CONCRETE SIDEWALK
CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
APPARENT RIGHT-OF-WAY
SIG
N
BU
S STO
P
D-3
STO
P SIG
N
3 101
10" STEEL
10" STEEL
6" CLAY
3' C
LF
3.87 2.97
3.26 2.85
3.393.04
3.39 3.04
3.292.86
3.363.03
3.32 3.023.28 2.99
3.322.99
3.132.94
3 2088 2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
2.81
1017 10
W
W
9"
W
E
W
E W
W
W
W
8"
W
SIG
N
N
O
TR
U C
K
STO
P
SIG
N
SIG
N
D
EAD
EN
D
D-2
SIG
N
BU
S STO
P
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-WAY
STO
P
SIG
N
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK CONCRETE SIDEWALK
2' CURB & GUTTER
2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
12" RCP
15" R
C P
6" PLASTIC PIPE
15" RCP
6" PLASTIC PIPE
APPARENT RIGHT-OF-WAY
D-3 D-1
C O
LU
M
N
5.02 4.71
5.12 4.80
5.14 4.80
4.964.62
4.76 4.54
4.45 4.54
5.06 4.77
5.16
4.90 5.25
4.93
5.68 5.20
5.46 5.19
4.78 4.62
4.724.36
4.75 4.40
5.62 5.12
5.44 5.04
4.78 4.42
4.55 4.22
4.80 4.42
4.874.42
4.784.44
SER
VIC
E
BO
X
5.194.80
APPARENT RIGHT-OF-WAY
4.46 4.42
4.85
4.81 4.984.82
4.69 4.65
1017 10
W
W
9"
W
E
W
E W
W
W
W
8"
W
SIG
N
N
O
TR
U C
K
STO
P
SIG
N
SIG
N
D
EAD
EN
D
D-2
SIG
N
BU
S STO
P
STO
P
SIG
N
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK CONCRETE SIDEWALK
2' CURB & GUTTER
2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
12" RCP
15" R C
P
6" PLASTIC PIPE
15" RCP
6" PLASTIC PIPE
D-3
D-1
C O
LU
M
N
5.02 4.71
5.12 4.80
5.14 4.80
4.964.62
4.76 4.54
4.45 4.54
5.06 4.77
5.16
4.90 5.25
4.93
5.68 5.20
5.46 5.19
4.78 4.62
4.494.19 4.654.35
4.724.36
4.75 4.40
5.62 5.12
5.44 5.04
4.78 4.42
4.55 4.22
4.80 4.42
4.874.42
4.784.44
SER
VIC
E
BO
X
5.194.80
4.46 4.42
4.85
4.81 4.984.82
4.69 4.65
1017 10
W
W
9"
W
E
W
E W
W
W
W
8"
W
SIG
N
N
O
TR
U C
K
STO
P
SIG
N
SIG
N
D
EAD
EN
D
D-2
SIG
N
BU
S STO
P
STO
P
SIG
N
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK CONCRETE SIDEWALK
2' CURB & GUTTER
2' CURB & GUTTER2' CURB & GUTTER
2' CURB & GUTTER
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
6" VER
TIC
AL C
U
R B
12" RCP
15" R C
P
6" PLASTIC PIPE
15" RCP
6" PLASTIC PIPE
D-3
D-1
C O
LU
M
N
5.02 4.71
5.12 4.80
5.14 4.80
4.964.62
4.76 4.54
4.45 4.54
5.06 4.77
5.16
4.90 5.25
4.93
5.68 5.20
5.46 5.19
4.78 4.62
4.494.19 4.654.35
4.724.36
4.75 4.40
5.62 5.12
5.44 5.04
4.78 4.42
4.55 4.22
4.80 4.42
4.874.42
4.784.44
SER
VIC
E
BO
X
5.194.80
4.46 4.42
4.85
4.81 4.984.82
4.69 4.65
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
DEAD
END
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
DEAD
END
" 1
1"
W
W
T
W
TV
G
W
W
W
W
2' CURB & GUTTER
2' CURB & GUTTER
2' CURB & GUTTER
2' C U
R B & G
U
TTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT
BIKE LANE
NO OUTLET
STO
P
SIG
N
STO
P
SIG
N
STO
P
SIG
N
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAYAPPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
79CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALKCONCRETE SIDEWALK
C O
N C
R
ETE SID
EW
ALK
TO
P O
F BAN
K
TO
P O
F BAN
K
2' CURB & GUTTER
18" RCP
18" RCP
15" R C
P
18" RCP 18" RCP
6" VER
TIC
AL C
U
R B
24"x37" RCP
-1
D -1
D -2
D-3
D-4
D -5
D -6 D-7
6" PLASTIC PIPE
7' W x 2' H BO
X CULVERT
7' W x 2' H BO
X CULVERT
6" PLASTIC
6" PLASTIC
6" PVC
SIGN:
DOUBLE ARROW
D-8
C
AN
AL
LO
T 26
LO
T 22
LO
T 12
APPAR
EN
T R
IG
H T-O
F-W
AY
D-9
D-10
COLUMN
4.273.89
4.123.76
4.083.71
3.973.68
4.093.80
3.993.64
3.94 3.70
3.97 3.59
3.67 3.33
3.58 3.10
3.58 3.01
3.88 3.79
3.81
3.59 4.27
3.92
4.22 3.86
4.09 3.66
4.21 3.91
3.77 3.72
3.51 3.26
3.633.61
3.77 3.68
3.40 3.21
3.84 3.80
VVH10
VVH10
G
" 1
1"
W
W
T
W
TV
G
W
W
W
W
2' CURB & GUTTER
2' CURB & GUTTER
2' CURB & GUTTER
2' C U
R B & G
U
TTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT
BIKE LANE
NO OUTLET
STO
P
SIG
N
STO
P
SIG
N
STO
P
SIG
N
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAYAPPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
79CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALKCONCRETE SIDEWALK
C O
N C
R
ETE SID
EW
ALK
TO
P O
F BAN
K
TO
P O
F BAN
K
2' CURB & GUTTER
18" RCP
18" RCP
15" R C
P
18" RCP 18" RCP
6" VER
TIC
AL C
U
R B
24"x37" RCP
-1
D -1
D -2
D-3
D-4
D -5
D -6 D-7
6" PLASTIC PIPE
7' W x 2' H BO
X CULVERT
7' W x 2' H BO
X CULVERT
6" PLASTIC
6" PLASTIC
6" PVC
SIGN:
DOUBLE ARROW
D-8
C
AN
AL
APPAR
EN
T R
IG
H T-O
F-W
AY
D-9
D-10
COLUMN
4.273.89
4.123.76
4.083.71
3.973.68
4.093.80
3.993.64
3.94 3.70
3.97 3.59
3.67 3.33
3.58 3.10
3.58 3.01
3.88 3.79
3.81
3.59 4.27
3.92
4.22 3.86
4.09 3.66
4.21 3.91
3.77 3.72
3.51 3.26
3.633.61
3.77 3.68
3.40 3.21
3.84 3.80
VVH10
VVH10
G
" 1
1"
W
W
T
W
TV
G
W
W
W
W
2' CURB & GUTTER
2' CURB & GUTTER
2' CURB & GUTTER
2' C U
R B & G
U
TTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT
BIKE LANE
NO OUTLET
STO
P
SIG
N
STO
P
SIG
N
STO
P
SIG
N
APPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAYAPPARENT RIGHT-OF-WAY
APPARENT RIGHT-OF-WAY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
APPAR
EN
T R
IG
H T-O
F-W
AY
79CONCRETE
DRIVEWAY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CONCRETE SIDEWALKCONCRETE SIDEWALK
C O
N C
R
ETE SID
EW
ALK
TO
P O
F BAN
K
TO
P O
F BAN
K
2' CURB & GUTTER
18" RCP
18" RCP
15" R C
P
18" RCP 18" RCP
6" VER
TIC
AL C
U
R B
24"x37" RCP
-1
D -1
D -2
D-3
D-4
D -5
D -6 D-7
6" PLASTIC PIPE
7' W x 2' H BO
X CULVERT
7' W x 2' H BO
X CULVERT
6" PLASTIC
6" PLASTIC
6" PVC
SIGN:
DOUBLE ARROW
D-8
C
AN
AL
APPAR
EN
T R
IG
H T-O
F-W
AY
D-9
D-10
COLUMN
4.273.89
4.123.76
4.083.71
3.973.68
4.093.80
3.993.64
3.94 3.70
3.97 3.59
3.67 3.33
3.58 3.10
3.58 3.01
3.88 3.79
3.81
3.59 4.27
3.92
4.22 3.86
4.09 3.66
4.21 3.91
3.77 3.72
3.51 3.26
3.633.61
3.77 3.68
3.40 3.21
3.84 3.80
VVH10
VVH10
G
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
NO
OUTLET
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
R
AUULTLT
NO
OUTLET
501350
TV
W
T
TV
W
W
WW
W
IN
BIKE LAN
E
SIG
N
BIKE
LAN
E
2' CURB & GUTTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT VAU
LT
VAU
LT
VAULT
2' C U
R B & G
U
TTER
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CO
NCRETE DRIVEW
AY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
6" VER
TIC
AL C
U
R B
D -1
D-2
C O
N C
R
ETE D
R
IVEW
AY
C O
LU
M
N
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-W
AY
18" RCP
18" R C
P
24" RCP
6' CLF
APPAR
EN
T R
IG
H T-O
F-W
AY
6" VER
TIC
AL C
U
R B
6" VERTICAL CURB
STO
P
SIG
N
16.25 15.9116.32
16.13
15.89 15.45
16.08 15.64
16.37
15.92
2' CURB & GUTTER
15.8615.45
15.92 15.52
15.77 15.61
15.93 15.71
16.17 15.69
16.1515.70
16.08 15.66
15.88
15.64 15.84
15.63
16.74
16.30
16.54 16.17
16.30 16.01
16.21
15.80
16.14 15.72
16.21 15.84
16.2516.26
38"x24" ERCP
STOP
SIGN
16.03 16.08
APPAR
EN
T R
IG
H T-O
F-W
AY
APPARENT RIGHT-OF-WAY
501350
TV
W
T
TV
W
W
WW
W
IN
BIKE LAN
E
SIG
N
BIKE
LAN
E
2' CURB & GUTTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT VAU
LT
VAU
LT
VAULT
2' C U
R B & G
U
TTER
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CO
NCRETE DRIVEW
AY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
6" VER
TIC
AL C
U
R B
D -1
D-2
C O
N C
R
ETE D
R
IVEW
AY
C O
LU
M
N
18" RCP
18" R C
P
24" RCP
6' CLF
6" VER
TIC
AL C
U
R B
6" VERTICAL CURB
STO
P
SIG
N
16.25 15.9116.32
16.13
15.89 15.45
16.08 15.64
16.37
15.92
2' CURB & GUTTER
15.8615.45
15.92 15.52
15.77 15.61
15.93 15.71
16.17 15.69
16.1515.70
16.08 15.66
15.88
15.64 15.84
15.63
16.74
16.30
16.54 16.17
16.30 16.01
16.21
15.80
16.14 15.72
16.21 15.84
16.2516.26
38"x24" ERCP
STOP
SIGN
16.03 16.08
501350
TV
W
T
TV
W
W
WW
W
IN
BIKE LAN
E
SIG
N
BIKE
LAN
E
2' CURB & GUTTER
2' C U
R B & G
U
TTER
VAULT
VAULT
VAULT VAU
LT
VAU
LT
VAULT
2' C U
R B & G
U
TTER
CONCRETE SIDEWALK
CONCRETE SIDEWALK
CO
NCRETE DRIVEW
AY
CONCRETE SIDEWALK
CONCRETE SIDEWALK
6" VER
TIC
AL C
U
R B
D -1
D-2
C O
N C
R
ETE D
R
IVEW
AY
C O
LU
M
N
18" RCP
18" R C
P
24" RCP
6' CLF
6" VER
TIC
AL C
U
R B
6" VERTICAL CURB
STO
P
SIG
N
16.25 15.9116.32
16.13
15.89 15.45
16.08 15.64
16.37
15.92
2' CURB & GUTTER
15.8615.45
15.92 15.52
15.77 15.61
15.93 15.71
16.17 15.69
16.1515.70
16.08 15.66
15.88
15.64 15.84
15.63
16.74
16.30
16.54 16.17
16.30 16.01
16.21
15.80
16.14 15.72
16.21 15.84
16.2516.26
38"x24" ERCP
STOP
SIGN
16.03 16.08
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
SPEED
LIM
IT
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
C R
O
SS W
ITH
C
AU
TIO
N
W
AIT FO
R
TR
AFFIC
TO
STO
P
SPEED
LIM
IT
NOTES:
1. FOR GENERAL NOTES, SEE STANDARD DETAIL-STORM STRUCTURE NOTES (S40-1).
2. SEE STANDARD DETAILS-CATCH BASIN FLOW LINE TRANSITIONS (S40-33) AND CATCH BASIN THROAT
CONFIGURATION (S40-32).
3. FOR SECTION PLAN VIEW, SEE STANDARD DETAIL-CATCH BASIN GENERAL (S40-36).
4. COMPENSATE FOR BASIN COVER AND WING, PITCH, AND SLOPE AS REQUIRED.
5. SLOPE BASIN AND WING COVER 1/4" TO 1/2" PER FOOT. COVERS TO MATCH SLOPE IF IN SIDEWALK.
6. REFERENCE POINT=INTERFACE BETWEEN WING COVER AND WING SHELF AT THE FACE.
=MINIMUM DIMENSION,
FIELD ADJUST AS
REQUIRED, SEE NOTE 4 SECTION D-D
REINF.-#4 @ 6" OC/EW, PLACE IN
MIDDLE OF SLAB AND WALLS
9-1/2"*
1'
-1 /2
6"
1" TO 2"*, SEE NOTE 4
1-1/2" BEVEL
6" TYPICAL
8" 8"2'-8"
4'-0"
TO ROADWAY
SECTION E-E
2- 1/
2"
5- 1/
2" 6- 1/
2"
1'
-1 /2
1' -1
"1" 8" 9"
TOP OF CURB
THROAT INVERT
WING COVER
10" 6"
TO ROADWAY
9-1/2"*
1'
-1 /2
6"
1" TO 2"*, SEE NOTE 4
1-1/2" BEVEL
6" TYPICAL8"
2- 1/
2"
5- 1/
2" 6- 1/
2"
1'
-1 /2
1' -1
"1" 8" 9"
TOP OF CURBWING COVER
6"
THROAT INVERT
1' 5-1/2"
REINFORCEMENT
1-1/2" BEVEL
TOP OF CURB
1" 8" 9"
1' -1
WING COVER THROAT INVERT
1" 1'
-1 " 6"
6"
8" 3'-6" 4'-10"
8"
BASIN COVER
SEE NOTE 6
REINF.-#4 @ 6" OC/EW, PLACE IN
MIDDLE OF SLAB AND WALLS
6"
SECTION C-C
CITY OF ST. PETERSBURG STANDARD DETAIL S40-48 CITY OF ST. PETERSBURG STANDARD DETAIL S40-49
NOTES:
1. FOR GENERAL NOTES, SEE STANDARD DETAIL-STORM STRUCTURE NOTES (S40-1).
2. NOSING SHALL BE USED WHERE SHOWN ON THE PLANS OR WHEN BASIN IS IN CURB RADII.
3. REINFORCEMENT SHOWN IS FOR STANDARD SIZES SHOWN. MAINTAIN REINFORCMENT SIZE,
AND SPACING, AND ADD ADDITIONAL BARS FOR MODIFIED STRUCTURES.
6" 6"
6" 6" 6" 6" 6" 6" 2"2"
2" 2"
2-3/8" EACH
#7 BARS/EW
#4 BARS/EW
TYPICAL SECTION C-C
TYPICAL SECTION E-E
6" 6" 6" 6" 6" 6"
2" 2"
2" 2"
1-7/8" EACH
1/2" RADII
4-3/8"
1-3/4" EACH
1-7/8"
2"
TYPICAL SECTION E-ETYPICAL SECTION C-C
1-1/2"4" 8"
8"
8"
8" 8"
8"1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 9-1/2"
9- 1/
2"
6- 1/
2"
4'-6" 4'-0"
BOTTOM REINFORCEMENT-#7 E/W
SEE NOTE 2
ADDITIONAL #4 BAR
3" COVER
SEE NOTE 2
TOP REINFORCEMENT-#4 E/W
C
E
E
C
CITY OF ST. PETERSBURG STANDARD DETAIL S40-58
NOTES:
1. FOR GENERAL NOTES, SEE STANDARD DETAIL-STORM STRUCTURE NOTES (S40-1).
2. ALL BASIN AND WING COVERS SHALL BE REMOVABLE. EDGES AND SEAMS SHALL NOT BE GROUTED.
3. ACCESS OPENING SHALL BE REQUIRED AT EACH CATCH BASIN STRUCTURE. STRUCTURES WITH MULTIPLE
COVERS, ACCESS OPENING SHALL BE ALIGNED WITH CENTER LINE OF THE LARGEST PIPE IN STRUCTURE.
4. PRE-CAST CATCH BASINS, UPPER 24" SHALL BE CAST IN PLACE.
5. SEE STANDARD DETAIL-TYPE I THRU V TYPICAL CATCH BASIN SECTIONS (S40-38).
6. SEE STANDARD DETAIL-TYPE I THRU V CATCH BASIN BASE AND WALL (S40-39).
7. SEE STANDARD DETAIL-CATCH BASIN COVER SLAB REINFORCING PLAN VIEW (S40-40).
8. SEE STANDARD DETAIL-CATCH BASIN COVER SLAB SECTIONS AND REINFORCING (S40-41).
9. SEE STANDARD DETAIL-TYPICAL WING ASSEMBLY (S40-47).
10. SEE STANDARD DETAIL-TYPICAL WING SHELF SECTIONS (S40-48).
11. SEE STANDARD DETAIL-WING COVER SLAB SECTIONS AND REINFORCING (S40-49).
12. SEE STANDARD DETAIL-CATCH BASIN THROAT CONFIGURATION (S40-32).
13. REFERENCE POINT=INTERFACE BETWEEN WING COVER AND WING SHELF AT THE FACE.
14. MAKE TOP SLAB PERFECTLY LEVEL.
TYPICAL ASSEMBLY OF UPPER COMPONENTS
STANDARD CATCH BASIN TYPES
TYPE V G2 TYPE V G3-M TYPE V G5-M2
TYPE lV G TYPE lV G2-M TYPE lV G4-M2
TYPE lll G TYPE lll G2-M TYPE lll G3-M2
TYPE ll G TYPE ll G2-M TYPE ll G2-M2
TYPE l G TYPE l G-M TYPE l G-M2
BASIN COVER SLAB, W/O WING
BASIN COVER SLAB, W/ WING
THROAT PITCH
BASIN THROAT
SEE NOTE 4
TYPE I, II, AND III RISER
TYPE IV AND V RISER
GRATE FRAME AND GRATE ACCESS OPENING
(SQUARE) SEE STANDARD DETAIL S40-59 ONLY
WING COVER SLAB
1-1/2" BEVEL
WING THROAT
SEE NOTE 14
WING SHELF
SEE NOTE 3, BELOW ALTERNATE WING LOCATION
ALTERNATE WING LOCATION
ALTERNATE WING LOCATION
ALTERNATE WING LOCATION
ALTERNATE WING LOCATION
SEE NOTE 3, BELOW
SEE NOTE 3, BELOW
SEE NOTE 3, BELOW
SEE NOTE 3, BELOW
ROUND ROUND
ROUND ROUND
ROUND
S-1 MODIFICATION DETAIL
Test Hole Date
Test Hole Number
Utility Size, Material & Type (Size measured in inches and is
O.D.)
Station Offset Northing Easting Ground
Elevation
Manual Depth (Top)
Utility Elevation
(Top) Utility Owner
Utility Direction
Surface Type
3/6/2024 VVH101 2" Polyethylene Gas Main 51+29.81 -28.80 LT 1240479.75 435099.43 4.02 1.45 2.57 TECO N-S Soil
3/6/2024 VVH102 2" Polyethylene Gas Main 51+75.25 47.82 RT 1240525.92 435175.62 4.40 2.88 1.52 TECO E-W Soil
1. TOPOGRAPHIC and RECORD Survey of 37th St S and 26th Ave S Intersection, lying in Section 34, Township 31 South, Range 16 East, City of St. Petersburg, Pinellas County, Florida.
2. Survey Date: March 16, 2023.
3. Prepared for the exclusive benefit of: WSP
4. Coordinates for project control points were established by Real-Time Kinematic GPS methodology utilizing the Florida
Permanent Reference Network (FPRN) for corrections. The Horizontal Datum is relative to the North American Datum of 1983, 2011 Adjustment (NAD83/2011). Elevations of project control points were established by a digital level benchrun beginning on NGS Control Point POWER G (PID=AG0810, Northing= 1,243,088.38, Easting = 436,387.61 Elevation=33.34'). Elevations are relative to the North American Vertical Datum of 1988 NAVD 130 C OF SP (PID= AG7089, Elevation = 35.20')
6. TOPOGRAPHIC SURVEY extends to apparent Right-of-Way to Right-of-Way on South Lagoon Street and South Troydale Road , and includes any hardscape elements and above ground utilities, including but not limited to all retaining walls, fences, culverts, drainage structures, paved ditches, water meters, valves, junction boxes, manholes, driveways, parking lots, utility/light poles, horizontal location of overhead utility lines, trees of 4” diameter or greater, and any other significant feature within the survey areas identified above. Visible above ground utilities are shown herein however additional utilities may exist.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .