About this file

This addendum document provides architectural drawings and construction details for the Fresno Air Attack Base C-130 Barracks project located at 2311 N. Clovis Avenue, Fresno, California 93727, under the Department of Forestry and Fire Protection (CAL FIRE). The addendum includes floor plans, reflected ceiling plans, roof plans, exterior elevations, and enlarged interior elevation details for the barracks/mess hall facility. Key project components encompass a multi-room structure featuring six bedrooms, three bathrooms, kitchen and pantry areas, dining room, day room, library, physical training hall, laundry room, and various support spaces totaling approximately 4,200 square feet. The building design incorporates accessibility features including ADA-compliant clearances, accessible work surfaces, and removable millwork in designated accessible bedrooms. A mandatory site visit was scheduled for October 6, 2025, at 10:00 a.m., with a bid submission deadline of December 1, 2026, at 2:00 p.m., followed by a virtual bid opening at 3:00 p.m. on the same date. The project requires contractors' state license classification B, with potential need for fire protection specialty contractor license classification C-16.

The State's project estimate is $5,192,000.00. Specifications detail construction requirements including metal standing seam roofing with cool roof properties, cement plaster exterior siding, 2x6 wood framed walls with R-21 batt insulation and exterior rigid insulation at perimeter walls, gypsum board interior finishes, and integrated color coated prefinished metal gutters and downspouts. Fire-rated wall assemblies include 1-hour fire-rated partitions separating sleeping units from common areas, with specific flame spread and smoke density ratings per ASTM E84 standards. The project incorporates roof venting calculations meeting 1/300 ventilation ratios with 50 percent high and 50 percent low venting areas distributed across multiple roof sections. Additional requirements include waterproof flashing at all roof penetrations, soil cement board soffits, and coordination with mechanical, electrical, and plumbing systems for all building penetrations and utility connections.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L# LOUVER NUMBER

# WINDOW NUMBER

A001

ARCHITECTURAL GENERAL

SHEET ABBREVIATIONS AND

NOTES

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge me n t

To we rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V3

ARCHITECTURAL SYMBOLS

X SIGNAGE NUMBER OR LETTER

DOOR IDENTIFIER:

SIGNAGE IDENTIFIER:

WINDOW IDENTIFIER:

LOUVER IDENTIFIER:

CONSTRUCTION DETAIL CALLOUTS

1. SEE DETAIL #7 / A501 FOR EQUIPMENT CURB AT ROOF.

2. SEE DETAIL #9 /A501 FOR OPENINGS THROUGH EXTERIOR WALL FOR MECHANICAL, PLUMBING OR ELECTRICAL COMPONENTS.

3. SEE DETAIL #1 / A502 FOR SLOPED CEILING AT SHOWER.

4. SEE DETAIL #9 / A502 FOR FIRE EXTINGUISHER CABINET IN 1-HOUR RATED WALL ASSEMBLY.

5. SEE DETAIL #4 / A503 FOR INTERIOR WALL CONCRETE CURB.

6. SEE DETAIL #5 / A503 FOR WOOD TRIM AT SIDING.

7. SEE DETAIL #10 / A503 FOR OUTSIDE CORNER AND INSIDE CORNER TRIM FOR SIDING.

8. SEE DETAIL #10 / A504 FOR HEAD AND JAMB OF INTERIOR WALL CASE OPENING.

9. SEE DETAIL #15 / A504 FOR INTERIOR WALL CORNER.

HOUR / HEAT WATER RETURN

SOAP DISPENSER / STORM DRAIN

EDGE OF PAVING

EDGE OF SLABEOS

EOP L

LAV LAVATORY / LAVATORY SINK

LENGTH

SD

SCR SCREEN

ELECTRICAL DRINKING FOUNTAIN

EDGE NAILING

ELECTRICAL OVERHEAD

EXPANSION JOINT

EXHAUST FAN

ELEC

EOH

ELECTRICAL

ELEVATION

EDF

EA W

EACH

EACH WAY

EXISTING

EAST

JST

KVA

KM

KIT

INT

JT

JAN

JB

INV

DISH WASHER

DISPENSER / DISPOSAL

DWR

DWG

DOWN

DRAWER

DRAWING

DOWNSPOUT

DOOR

DIAG

DISC

DIST

DISP

DIAMETER

DIMENSION

DISTANCE

DISCONNECT

DIAGONAL

HW

INSUL

IN

I

ID

HR

HVAC

HTR

HW

HT

HSE

KITCHEN

KILOMETER

KILO VOLT AMPERE

JOIST

INTERIOR

JANITOR

JUNCTION BOX

JOINT

INVERT

SOUTH / SANITARY

SEAT COVER DISPENSER

SCHEDULED

SOLID CORE

SUPPLY AIR

S

SCHED

SCD

SC

SA

REVOLUTIONS PER MINUTE

REDWOOD

RETAINING WALL

RAIN WATER LEADER

RELIEF VALVE

RT

RPM

RIGHT

RWD

RWL

RW

RV

INSIDE DIAMETER / INSIDE DIMENSION

HOT DOMESTIC WATER

INSULATION

INCH

CURRENT

HEATING, VENTILATING, AIR CONDITIONING

HOT WATER

HEATER

HEIGHT

HOUSE

REQUIRED

ROUGH OPENING

REVISION

REQ

RET RETURN

RND

RO

RM

ROUND

ROOM

REV

REFLECTED CEILING PLAN

RECEPTACLE

REGISTER

REINFORCED

REFRIGERATOR

REFERENCE

RECEPT

RCP

REINF

REFR

REG

REF

WELDED WIRE FABRIC

WATER RESISTANT

WATER HEATER / WHARF HYDRANT

WV

WWF

WT

XFMR

WEIGHT

WATER VALVE

TRANSFORMER

WH

WIND

WCO

WD

WR

WP

WINDOW

WOOD

WALL CLEANOUT

WATERPROOF

VENT THROUGH ROOF

WEST / WASHER / WATER / WIDTH

VAPOR RETARDED / VENT RISER

W/ W

VTR

WC

W/O

WITH

WATER CLOSET

WITHOUT

VENT

VIF

VERT

VD

VR

VOL

VERTICAL

VENTILATOR

VERIFY IN FIELD

VOLUME DAMPER

VOLUME

RADIUS / RISER / RESISTANCE

PRESSURE TREATED DOUGLAS FIR

MO MASONRY OPENING

ARCH ARCHITECTURAL FL FLOW LINE / FLASHING

PLN PLAN

GALV GALVANIZEDCLEAR

GYP BDCERAMIC TILE

DOUGLAS FIR / DRINKING FOUNTAIN

DRYER / DAMPER

DBL

DEMOLISH

DRAIN INLET

DETAIL

DOUBLE

CU FT CUBIC FEET

CENTER

COLD WATER

CUBIC YARD

HD

HDWD

HORIZ

HDWR

HM

HDR

HC

H2O

HB

CORRUGATED METAL PIPE

CONTINUATION / CONTINUOUS

CONCRETE MASONRY UNIT

CLEAN OUT TO GRADE

CLEAN OUT TO FLOOR

CONT

CMP

COTF

COTG

CORR

CONT CONTINUOUS

CORRIDOR

CONC

COND

CMU

COL

CONCRETE

CONDENSER

CLEAN OUT

COLUMN

GPH

GSM

GYP

GSP

GR

GPM

GEN

GFCI

GND

GI

GB

PTDF

GYPSUM BOARD

HOLLOW METAL

HORIZONTAL

HARDWARE

HOLD DOWN

HARDWOOD

HEADER

HOLLOW CORE

HOSE BIB

WATER

QUANTITY

QUARRY TILE

RETURN AIR

RELOCATE

QT

QTY

RA

R (R)

PAVEMENT

PARTITION

POLYVINYL CHLORIDE

PLYWOOD

PVMT

PTN

PVC

PLYWD

GALLONS PER HOUR

GALVANIZED SHEET METAL

GALVANIZED SHEET PIPE

GALLONS PER MINUTE

GYPSUM

GRADE

GROUND FAULT CIRCUIT INTERRUPTER

GROUND

GALVANIZED IRON

GENERATOR

GRAB BAR

PSF POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PERFORATED STEEL PIPE

PAPER TOWEL DISPENSER

POINT / PRESSURE TREATED

PAINT / STAIN

PSP

PSI

PTD

PT

PT

PLYWOOD

PERFORATED PLASTIC PIPE

PIPE SLEEVE

POWER POLE

PLWD

PNL PANEL

PPP

PS

PP

FPSCONDUIT

CUBIC FEET PER MINUTE

CALIFORNIA BUILDING CODE

CATCH BASIN / CIRCUIT BREAKER

CHAIN LINK FENCE

CENTER LINE

CONSTRUCTION JOINT

CLG

CLO CLOSET

CEILING

CIRCLE

CFM

CBC

CAB

CAST IRON

CABINET

FURN

GA

GAL

G&O G

FRZ

FTG

FT

FS

FRP

BENCH MARK

BUILDINGBLDG

BOT

B/M

BLKG

BOTTOM

BEAM

BLOCKING

AUTO

AVERAGE

ATTIC VENT

BOARD

AUTOMATIC

FOB

FPM

FOF

FOC

FOS

FOM

FLR

FLUOR

FO

FND

FN

OBS OBSCURE

FEET PER SECOND

FURNACE / FURNITURE

GAUGE

GALLON

GAS & OIL

GAS

FIBERGLASS REINFORCED PANEL

FREEZE

FLOOR SINK

FOOTING

FOOT / FEET

OPP OPPOSITE

PLATE / PROPERTY LINE

PLASTER

POLE / POWER

PLASTIC LAMINATE

P

PLAS

P LAM

PL

OUTSIDE DIAMETER

ON CENTER

OVERHEAD

OR EQUAL

OD

OC

OFF

OH

OFFICE

O/E

FACE OF BLOCK

FEET PER MINUTE

FACE OF STUD

FACE OF CONCRETE

FACE OF MASONRY

FACE OF FINISH

FACE OF / FINISH OPENING

FLOOR

FLUORESCENT

FOUNDATION

FIELD NAILING

N NORTH

NOT TO SCALE

NOT IN CONTRACTNIC

NO

O/

NTS

OVER

NUMBER

MOUNTED

MULLION

NEW

MTL

MTD

METAL

(N)

MUL

ASPHALT CONCRETE PAVING

ADJACENT / ADJUSTABLE

AIR CONDITIONING

APPROXIMATE

ABOVE FINISH FLOOR

APPROX

AGG

ALUM

ALTERNATE

ALUMINUM

AGGREGATE

A/C

ACP

AIR

EQUAL

FEC

FF

FG

FIN

FIXT

FH

FA

FD

FE

FACP

CENTER LINE

FOOT / FEET

PLATE / PROPERTY LINE

INCH / INCHES

NUMBER

DIAMETER

AND

AT

ETC

EXH

EUG

EXT

EXP

EXIST

EQ

EQUIP

FIRE EXTINGUISHER CABINET

FINISH GRADE / FLOOR GRILLE

FINISH FLOOR

FINISH

FIXTURE

FIRE HYDRANT

FIRE ALARM CONTROL PANEL

FLOOR DRAIN / FIRE DAMPER

FIRE ALARM

FIRE EXTINGUISHER MICRO MICROWAVE

MISCELLANEOUS

MILLIMETER

MINIMUM

MANHOLE

MISC

MM

MIR

MIN

MH

MIRROR

MEMBRANE

MECHANICAL

MEDICINE CABINET

MEZZANINE

MANUFACTURER

MEMB

MECH

MC

MEZZ

MFG

ELECTRICAL UNDERGROUND

EXHAUST

ET CETERA

EXPANSION

EXTERIOR

EXISTING

EQUAL

EQUIPMENT

MAXIMUM

LIQUID PETROLEUM GAS

LIQUID SOAP DISPENSER

LIGHTING

LINEAR FEET

MAX

LPG

LSD

LF

LTG

LAMINATELAM

LB POUND

SST STAINLESS STEEL

TOG TOP OF GRATE / TOP OF GRADE

TYP TYPICAL

UNLESS OTHERWISE NOTED

VINYL COMPOSITION TILE

VAL

UR

V

VCT

VAR

VALVE

URINAL

VOLT

VARIES

UNFIN

UGND

UH

UON

UNDERGROUND

UNIT HEATER

UNFINISHED

TELEPHONE OVERHEAD

TOP OF PAVEMENT

TELEPHONE TERMINAL CABINET

TOILET SEAT COVER DISPENSER

TOILET PAPER DISPENSER

TELECOMMUNICATION TERMINATION BOARD

TELEPHONE UNDERGROUND

TS TUBE STEEL

TSCD

TTC

TTB

TV

TUG

TELEVISION

TOW

TOS

TOP

TOH

TPD

TOP OF WALL

TOP OF SLAB

SYS SYSTEM

TOP AND BOTTOM

TONGUE AND GROOVE

TEMPERATURE / TEMPERED

TEL TELEPHONE

TOF

TEMP

TJ

TNK

TOC

TANK

TOP OF FOOTING

TOOLED JOINT

TOP OF CURB

T&G T&B T

TB

TREAD / TREE

TOWEL BAR

SYMBOL / SYMMETRICAL

SURF SURFACE

SWBD

SYM

SW

SYMM

SUSP

SWITCHBOARD

SANITARY WASTE

SYMMETRICAL

SUSPENDED

STRUCT

STOR

STL

STD

STA

STORAGE

STEEL

STRUCTURAL

STATION

STANDARD

SANITARY NAPKIN RECEPTACLE

SANITARY NAPKIN DISPENSER

STRUCTURAL PLYWOOD

SANITARY NAPKIN TAMPON VENDOR

SANITARY SEWER / SERVICE SINK

SP

SQ FT

SPKR

SQ

SPEC

SS

SPEAKER

SQUARE

SQUARE FEET

SPECIFICATIONS

SND

SNR

SL

SM

SNTV

SLOPE

SHEET METAL

SQUARE FOOT / SQUARE FEET

SHWR

SHTG

SI

SHT

SK

SIM

SHOWER

SHEET

SQUARE INCH

SHEATHING

SINK

SIMILAR

SF

SECT SECTION

A

Ø

EN

EL

EJ

EF

EA

(E) E

DN

DW

DR

DS

DIA

DIM

CLR

CT

(D)

DF

DI

DET

D

CW

CY

CTR

CO

CLF

CJ

CL

CIR

CB

CI

BM

C

AV

BD

AVG

ADJ

ALT

AFF

TG TEMPERED GLASS

ABBREVIATIONS

S C A L E : 2NOT TO SCALEACCESSIBLE CLEARANCES AT DOORS

*ADD 6" AT EXTERIOR

SIDE OF EXTERIOR DOOR

FRONT APPROACH,

PULL SIDE

" M

IN

FRONT APPROACH,

PUSH SIDE

" M

IN

12"

MIN.

FRONT APPROACH,

PULL SIDE, DOOR WITH

CLOSER AND LATCH

" M

IN

36" MIN.

HINGE APPROACH,

PULL SIDE

" M

IN

22"

MIN.

HINGE APPROACH,

PUSH SIDE

" M

IN

HINGE APPROACH,

PUSH SIDE, DOOR

PROVIDED WITH

BOTH CLOSER AND

LATCH

" M

IN

24"

MIN.

LATCH APPROACH,

PULL SIDE

" M

IN

24"

MIN.

LATCH APPROACH,

PUSH SIDE

" M

IN

24"

MIN.

LATCH APPROACH,

PUSH SIDE, DOOR

PROVIDED WITH

CLOSER

" M

IN

18"

MIN.*

22"

MIN.

DOOR NUMBER

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

\2

1A

1.

dw g

S ep

5,

- 4

:1 6P

M

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

1 SEPT 2026 ADDENDUM #1

FLAME SPREAD/SMOKE DENSITY

ALL INSULATION INSTALLED WITHIN FLOOR-CEILING ASSEMBLIES, ROOF-CEILING ASSEMBLIES, WALLS, CRAWL SPACES OR ATTICS SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25

AND A SMOKE DEVELOPED INDEX OF 450 WHEN TESTED IN ACCORDANCE WITH ASTM E84.

MAXIMUM FLAME SPREAD CLASS:

CLASS FLAME SPREAD INDEX

A 0-25 B 26-75 C 76-200

WASHER

DRYER

FACP

A404

B A201

A401

A401

A A201

C A201

D A201

G

8'-8"

'-8

'-3

6' -0

'-1 1"

'-8

7' -4

8'-8" 6'

-0

5'-4"

21'-7"

'-5

8'-8"9'-8"

4' -0

6'

-4

/2

5' -1

2'

-1 0"

4' -2

6'

-1

2' -8

6' -0

9'-8"

14'-8" 2'-4" 3'-6"13'-4"

5'-10"

11'-9"4'-6"11'-9"32'-0"

3' -6

5'-10"

'-1

4'

-4

'-1

/2

9'

-1

/2

'-1

1"

'-4

'-0

'-6

'-1 1"

6' -5

'-4

'-8

'-8

'-3

8'-7"

'-0

13'-4" 14'-8"

'-2

H

E

H

E

H

E

J

2' -4

20'-10"

8'-0"

8'-0"

'-0

8'-0"

16'-0"

K

N

N

H

M

AI

N

EN

TR

Y

6' -5

6'

-0

'-0

6'

-0

11'-5" 5'-2" 11'-5"

'-0

E

14'-0"7'-0"

LIBRARY

DINING

ROOM

KITCHEN

PHYSICAL

TRAINING

HALL 1

H A

LL

BATHRM

ENTRY

PANTRY

DAY ROOM

MECH

ELEC /

TELECOMM

BATHRM

BDRM 1 BDRM 6

BDRM 2 BDRM 5

STOR

LAUNDRY

TYP

TY

P

'-8

'-1

7' -0

A

8' -5

8'

-5

'-1

3'

-3

5' -8

20 16 B

2' -8

K

8'-6"

BDRM 3 BDRM 4

28'-0"

78'-6"

44'-8"

7'-0"

32'-0"

14'-0" 11'-0" 4'-2" 22" 4'-2" 2'-6"

6'-0" 6'-8"

1 5DS DS

DS

DS

DS

DS

DS

DS

DS

DS DS

DS

DS

DS DS

DS

DS

DS

DS

'-1

'-3

'-0

'-0

'-3

'-5

5'

-0

3' -1

0" 9'

-8

9' -7

12'-8"

7'-2" 4'-10" 5'-6"

3 3

4 10

'-0

2'

-0

2' -4

A401

A401

6'-2"

7' -1

0" 8'

-6

8'-5"

J

K

A502

11A A502

11B A502

I

H A

LL

24"

L

L

STOR 1

BATHRM

2'-7 1/2"

I

I

I I

5'-10"

A301

A301

A301

A302

A302

A302

M

M

2"

NN

NN

NN

A101

FLOOR PLAN

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V3

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

2\

A

1.

dw g S ep

6,

- 2 :4

4P M

PLAN

NORTH

SCALE: 3/16" = 1-0"

FLOOR PLAN

1. ROOF, TYP, SEE SHEET A131

2. BEAM, TYP, SEE STRUCTURAL SHEETS

3. FLATWORK, SEE GENERAL NOTE #4, TYP

4. INSTALL 1 LB SOUND SAFE ACOUSTICAL BARRIER

OVER STUDS ON INTERIOR SIDES OF BEDROOM

WALLS AND HALL3 WALLS BOTH SIDES.

5. DOWNSPOUTS ARE 6" FROM CORNERS, U.O.N., TYP

6. DISHWASHER

7. DOUBLE SINKS WITH DISPOSAL, SEE #3 / A505

8. RANGE WITH VENT HOOD

9. FREEZER

10. REFRIGERATOR

11. ACCESSIBLE SINK, SEE #2 / A505

12. WATER BOTTLE FILLING STATION

13. CURB, 6" W x 6" H x 10" L, EACH SIDE OF MAIN

ENTRANCE PORCH, SEE DETAIL #4 / A504

14. LOCKER TYP - SEE SHEET A405

15. PLUMBING EQUIPMENT, SEE PLUMBING SHEETS

16. WATER HEATER, SEE SHEET P102

17. FIRE RISER

18. CASED CORNER, SEE 7/A504

19. EMERGENCY KEY BOX, RECESSED 48" AFF; BOD:

KNOXBOX 3200, COLOR AS SELECTED BY

ARCHITECT.

20. NOT USED

21. NOT USED

22. DRYER

23. WASHER

GA FIRE RESISTANCE DESIGN MANUAL, EXPLANATORY NOTE #22

WHEN NOT SPECIFIED AS A COMPONENT OF A FIRE RESISTANCE RATED WALL OR PARTITION SYSTEM, WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO BE ADDED TO ONE OR BOTH SIDES. SUCH PANELS SHALL BE PERMITTED TO BE APPLIED EITHER AS A BASE LAYER DIRECTLY TO THE FRAMING (UNDER THE GYPSUM BOARD), AS A FACE LAYER (OVER THE FACE LAYER OF GYPSUM BOARD), OR BETWEEN LAYERS OF GYPSUM BOARD IN MULTI-LAYER SYSTEMS. WHEN SUCH PANELS ARE APPLIED UNDER THE GYPSUM BOARD OR BETWEEN LAYERS OF GYPSUM BOARD THE LENGTH OF THE FASTENERS SPECIFIED FOR THE ATTACHMENT OF THE GYPSUM BOARD APPLIED OVER THE WOOD STRUCTURAL PANELS SHALL BE INCREASED BY NOT LESS THAN THE THICKNESS OF THE WOOD STRUCTURAL PANELS. FASTENER SPACING FOR THE GYPSUM BOARD AND THE NUMBER OF

LAYERS OF GYPSUM BOARD SHALL BE AS SPECIFIED IN THE SYSTEM DESCRIPTION.

S C A L E :

NOT TO SCALE1 HOUR FIRE RATED ASSEMBLY

SHEET KEYNOTES

1. DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF OPENING TYP. (U.O.N.)

2. DIMENSIONS INDICATED AS "MIN. CLEAR" ARE TO FACE OF FINISH.

3. DIMENSION FROM DOOR OPENING TO ADJACENT PERPENDICULAR WALL SHALL BE 4" FROM F.O.S., TYP. (U.O.N.)

4. ALL PORCHES OR STOOPS CONNECT TO WALKWAYS AS SHOWN ON CIVIL SITE PLAN.

5. INSULATION: CEILING SHALL HAVE R-49 THERMAL BATT. VAULTED ROOF ASSEMBLY SHALL HAVE R-37 THERMAL BATT.

INSULATION AT ALL CONDITIONED SPACES. EXTERIOR WALLS SHALL HAVE R-21 BATT INSULATION AND EXTERIOR APPLIED

RIGID INSULATION AT PERIMETER WALLS.

6. WALL FRAMING SHALL INCLUDE BLOCKING AT LOCATIONS TO RECEIVE CABINETRY AND EQUIPMENT INCLUDING, BUT NOT LIMITED TO, GRAB BARS, LOCKERS, WALL MOUNTED DOOR STOPS, SHELVING, AND DISPENSERS.

7. SEE ENLARGED PLANS MORE INFORMATION.

8. SEE INTERIOR ELEVATIONS FOR MORE DETAILS.

9. SEE SHEET A111 FOR ACCESSIBILITY CLEARANCE & EXITING PLAN AND ROOM OCCUPANCY INFORMATION.

10. SEE FINISH SCHEDULE FOR INTERIOR FINISHES.

GENERAL SHEET NOTES

LEGEND

RFE FIRE EXTINGUISHER CABINET, SEMI-RECESSED:

COMMERCIAL GRADE 2A:10B:C MINIMUM. COORDINATE FINAL LOCATION WITH INTERIOR ELEVATIONS, SEE 9/A502

DOWNSPOUT

SIGN, SEE SHEET A500 FOR DOOR SIGNAGE TYPES

DOOR TAG, SEE SHEET A601

WINDOW TAG, SEE SHEET A601

DS

X

11 10 9

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

WALL LEGEND

EXTERIOR WALLS

2x6 WOOD STUDS @16" O.C. WITH R-21 BATT INSULATION. 1 1/2" RIGID INSULATION ON EXTERIOR, SEE

STRUCTURAL FOR SHEAR SHEATHING, INTERIOR 5/8" GYP. BD. (U.O.N.)

2x6 1-HOUR, SHEAR/FIRE WALL, GA FILE NO. WP 3661. SEE 10/A502.

INTERIOR WALLS

2x6 SHEAR WALL/SOUND WALL, WOOD STUDS @ 16" OC, R-21 BATT INSULATION, SHEATHING PER STRUCTURAL, 5/8" GYP. BD. EACH SIDE

2x6 WALL, WOOD STUDS @ 16" OC, (U.O.N.)

2x8 WALL, WOOD STUDS AT 16" OC, 5/8" GYP. BD. EACH SIDE (U.O.N.)

2x4 WALL, WOOD STUDS @16" OC, 5/8" GYPSUM BOARD EACH SIDE (U.O.N.)

2x6

2x6

2x6

2x6

2x6

1 SEPT 2026 ADDENDUM #1

1 1

A

2 3 4

B

D

C

FURNITURE, NIC

60" CLR

60" CLR

60" CLR

12"

24"

30" x 48"

CLR

30" x 48"

CLR

60" x 54"

CLR

MIN

CLR

60" x 60" CLR

MIN

CLR

60" x 60" CLR

24"

MIN

CLR48

" x

8" C

LR

M

IN

CL

R

" x

8"

C

LR

60" x 54"

CLR

24"

MIN

CLR

" x

8"

C

LR

18"

MIN

CLR

60" x 54"

CLR

19"

30" MIN34" WORK

SURFACE

" M

IN

" M

IN

30" x 48"

CLR

30" x 48"

CLR

30" x 48" CLR

12"

" x

8"

C

LR

MIN

CLR

MIN

CLR

60" x 60" CLR

24"

30" x 48"

CLR

MIN

CLR

60" x 58" CLR

22"

12"

" x

8"

C

LR

MIN

CLR

60" x 56"

CLR

12"

MIN

CLR48

" x

8" C

LR

" x

8"

C

LR

" x

8"

CL

R

60" x 54"

CLR

30" x 48" CLR

" x

8"

CL

R

60" x 54"

CLR

30" x 48"

CLR

30" x 48" CLR

30" x 48"

CLR

M

IN

CL

R

M

IN

CL

R

M

IN

CL

R

M

IN

CL

R

" x

8"

CL

R

22"

MIN

CLR

60" CLR

TYP

" x

8"

C

LR

" x

8"

C

LR

" x

8"

C

LR

" x

8"

C

LR

" x

8"

C

LR

" x

8"

CL

R

" x

8"

CL

R

M

IN

CL

R

" x

8"

C

LR

60" x 54"

CLR

M

IN

CL

R

" C

LR

36" CLR

36" CLR

24" CLR

24" CLR

" C

LR

LIBRARY

DINING

ROOM

KITCHEN

PHYSICAL

TRAINING

STOR

HALL 1

H A

LL

BATHRM

ENTRY

PANTRY

DAY ROOM

MECH

ELEC /

TELECOMM

BATHRM

LAUNDRY

BDRM 6BRDM 1

BDRM 2

BDRM 5

BDRM 3

BDRM 4

STOR

BATHRM

TYPICAL FOR ALL DOORS IN HALL 2 & 3

OL:33

OL:1

OL:1

OL

:3

OL

:3

OL

:3

OL:14

OL

:1

OL:36

OL

:5

OL

:5

OL:3OL:3

OL

:1

OL:3OL:3

OL:1

OL

:1

OL:1

OL:1OL:1

OL:1

OL:1

OL

:5

OL

:3

OL:3OL:3

OL:1

OL:1

OL

:1

OL

:6

OL

:1

OL:6

H A

LL

OL:2

ACCESSIBLE WORK

SURFACE AT BDRM 4

ACCESSIBLE LOCKER

AT BDRM 4

A111

ACCESSIBILITY AND EXITING

PLAN

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V3

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

6\

A

1.

dw g S ep

6,

- 2 :3

7P M

1. CLEAR FLOOR AREA REQUIRED FOR SIGNAGE / ROOM IDENTIFICATION SIGNS ARE

NOT SHOWN FOR CLARITY. PROVIDE CLEAR FLOOR AREA AT ALL SIGNS PER DETAIL

#3 / A500.

2. OBJECTS WITH LEADING EDGE MORE THAN 27 INCHES AND NOT MORE THAN 80

INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE 4 INCHES

MAXIMUM HORIZONTALLY INTO THE CIRCULATION SPACE.

3. ALL EXTERIOR EXITING DOORWAYS ARE 36" WIDE. BASED ON THE MEANS OF

EGRESS CAPACITY FACTOR 0F 0.20 INCHES PER OCCUPANT, THEN A 36" WIDE

EGRESS IS SUFFICIENT TO SERVE THE OCCUPANT LOADS PASSING THROUGH

THEM. ALL EXITING DOORWAYS IN THIS PROJECT ARE WELL BEYOND THIS

THRESHOLD.

4. DOORS SERVING 50 OR MORE OCCUPANTS ARE EQUIPPED WITH PANIC HARDWARE.

SEE DOOR SCHEDULE ON A601 FOR EQUIPPED DOORS.

5. A 1-HOUR FIRE PARTITION DIVIDES THE BUILDING'S SLEEPING UNIT (BEDROOMS

1-6) FROM THE BUILDING COMMON SPACE PER CBC 420.2. THIS PARTITION

INCLUDES AN INTERIOR 45-MINUTE RATED DOOR WITH A CLOSER PER CBC TBLE

716.1(2).

6. ON EACH SIDE OF THE DOOR CONNECTING THE SLEEPING UNIT TO THE COMMON

AREA, PANEL SIGNAGE SHALL BE POSTED WITH RAISED LETTERS AND BRAILLE

STATING "KEEP DOOR CLOSED". SEE SHEET A500.

7. AREAS OUTSIDE OF THE SLEEPING UNIT MAY NOT EGRESS THROUGH THE SLEEPING

UNIT. ILLUMINATED EXIT SIGNAGE IN THE COMMON AREA CORRIDOR CONNECTING

TO THE SLEEPING UNITS SHALL DIRECT EXITING TOWARDS COMMON ARE EXITS.

8. PER CBC TABLE 1006.2.1, AS A R-2 OCCUPANCY WITH NO MORE THAN 20

OCCUPANTS, THE SLEEPING UNIT IS SERVED BY A SINGLE EXIT.

9. EXIT SIGNAGE SHALL BE VISIBLE AT EXIT DOORS, INCLUDE ILLUMINATED EXIT

SIGNAGE AND PANEL SIGNAGE WITH RAISED LETTERS AND BRAILLE. SEE

ELECTRICAL FOR ILLUMINATE EXIT SIGNAGE AND A500 FOR PANEL SIGNAGE TYPES.

10. CORRIDORS WITHIN A SLEEPING UNIT ARE EXEMPT FROM FIRE-RESISTIVE RATINGS

PER CBC 1020.2, EXCEPTION 2.

PLAN

NORTH

SCALE: 3/16" = 1-0"

ACCESSIBILITY & EXITING PLAN

PLAN

NORTH

GENERAL NOTES

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

ROOM OCCUPANCY INFORMATION

ROOM NAME OCC. CLASS SQ. FT. O.L. FACTOR O.L.

DAY ROOM A-3 534.58 1/15 36

DINING ROOM A-3 488.43 1/15 33

KITCHEN & PANTRY B 349.87 1/200 2

STORAGE 1 B 65.64 1/300 1

BATHROOM 3 B 98.77 1/200 1

LAUNDRY B 101.29 1/200 1

BATHROOM 2 B 97.85 1/200 1

BATHROOM 1 B 98.77 1/200 1

PHYSICAL TRAINING B 289.67 1/50 6

STORAGE 2 B 58.22 1/300 1

MECHANICAL B 126.61 1/300 1

ELEC / TELECOMM B 70.49 1/300 1

BEDROOM 6 R2 124.44 1/50 3

BEDROOM 5 R2 124.44 1/50 3

BEDROOM 4 R2 124.00 1/50 3

BEDROOM 3 R2 124.00 1/50 3

BEDROOM 2 R2 124.44 1/50 3

BEDROOM 1 R2 124.44 1/50 3

LIBRARY A-3 174.77 1/15 12

A-3 / B / R-2 WITH SPRINKLER BLDG IS ALLOWED 250 FEET

FOR EXIT ACCESS TRAVEL DISTANCE. THIS BUILDING

MEETS THESE REQUIREMENTS.

TOTAL O.L. 115

1 SEPT 2026 ADDENDUM #1

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

J C

S

C

S

S

S

S

S S

SS

S

C

S

C

S

S S

S S

S S

S

LIBRARY

DINING

ROOM

KITCHEN PHYSICAL

TRAINING

STOR 1

HALL 1

H A

LL

BATHRM

ENTRY

PANTRY

DAY

ROOM MECH

ELEC / TELECOMM

BATHRM

LAUNDRY

BDRM 6BDRM 1

BDRM 2

BDRM 5

BDRM 3 BDRM 4

STOR 2

BATHRM

UPPER CABINETS, TYP

FOR ANCHORING SEE

DETAIL #6 / A504

GYPSUM CEILING

BOARD, TYP

RANGE HOOD

EXHAUST FLUE

A

TT

IC

W

A

LK

W A

Y

UPPER CABINETS,

TYP

RIDGE LINE OF

VAULTED CEILING

VAULTED CEILING

STOPS ALONG

THIS LINE

A

TT

IC

W

A

LK

W A

Y

ATTIC WALKWAY

TYP1

A501

EAVE

TYP

A501

RAKE

TYP

A501

ATTIC WALKWAY FRAMING

DETAIL SEE DETAIL #1

LOCATION OF CEILING

MOUNTED ELEMENTS TYPICAL

IN ALL BATHROOMS

CEILING MOUNTED ELEMENTS,

TYPICAL IN ALL BEDROOMS

ATTIC ACCESS, SEE DETAIL

#2 /A502, TYP

GALVANIZED SHEET METAL

GUTTER & DOWNSPOUT, TYP,

SEE DETAILS #6 & #7 / A502

2x FASCIA BOARD, TYP

FLAT PANEL FIBER CEMENT SOFFIT,

TYP

POST & BEAM, EXPOSED AREAS

TO BE PAINTED, TYP

SEE STRUCTURAL FOR SIZES

AND LOCATIONS

CONTINUOUS PREFINISHED

METAL SOFFIT VENT, TYP

2x EAVE FASCIA, TYP

ATTIC ACCESS, SEE GENERAL

NOTE #3 & #4, TYP FOR TWO

PORCH ATTIC ACCESS LOCATIONS

2:

V

AU

LT

ED

CE

IL

IN

G

SL

OP

E

DO

W N

2:

V

AU

LT

ED

CE

IL

IN

G

SL

OP

E

DO

W N

FLAT CEILING IN THIS AREA

FLAT CEILING IN THIS AREA

A301

A301

A301

A302

A302

A302

FL

AT

C

EI

LI

NG

IN

T

HI

S

AR

EA

V-GROOVE CEMENT BOARD AT

PORCHES AND SOFFITS, TYP

FLAT CEILING IN THIS AREA

FLAT CEILING IN THIS AREA

18x18 SELF-CLOSING

ACCESS HATCH IN ATTIC

SPACE

WALL LOUVER,

SEE MECH

PORCH

RAKE

TYP

A501

1"

1/ 2"

1' -0

PARALLEL TO TRUSS

PERPENDICULAR TO TRUSS

ROOF TRUSS

3/4" PLYWOOD W/ 8d @ 12" OC TO EA 2x12 & (3) 8d TO EA BLKG

2 x 12 BLKG @ 48" OC AT TRUSS

2 x 12 TO TRUSS BOTTOM CHORD W/ (2) 16d EACH SIDE @ 16" OC

STAGGERED TOP & BOTTOM

2 x 10 W/ H1 @ EACH CHORD

ROOF TRUSS BOTTOM CHORD

3/4" PLYWOOD W/ 8d @ 12" OC TO EA 2x12 & (3) 8d TO EA BLKG

2 x 12 BLKG @ 48" OC AT TRUSS &

LTP4 TO TRUSS BOTTOM CHORD

LTP4

(2) 16d @ 2 x 12 TO BLKG EA SIDE

(2) 16d @ 2 x 12 TO BLKG EA SIDE

A121

REFLECTED CEILING PLAN

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V2

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

2\

A

1.

dw g S ep

6,

- 2 :4

1P M

GENERAL NOTES

1. NOT USED.

2. SEE ELECTRICAL FOR SERVICE LIGHT AND OUTLET IN ATTIC SPACE / BY PULL DOWN ATTIC ACCESS LADDER.

3. NOT USED

4. ATTIC ACCESS IN PORCHES SHALL BE ONE HOUR FIRE RATED AND HAVE LOCKABLE LATCH. PAINT TO MATCH

ADJACENT FINISHES.

5. COORDINATE ALL CEILING & SOFFIT PENETRATION LOCATIONS WITH CEILING JOIST LAYOUT.

6. CEILING HEIGHT IS 9'-0", EXCEPT AT DAY AND DINING ROOMS, SEE ROOM FINISH SCHEDULE FOR FINISHES.

7. NOT USED

8. NOT USED

PLAN

NORTH

SCALE: 3/16" = 1-0"

REFLECTED CEILING PLAN

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

SYMBOL LEGEND

FOR ALL LIGHT FIXTURES, REFER TO ELECTRICAL LIGHT FIXTURE MOUNTING REQUIREMENTS. SEE ELECTRICAL

AND MECHANICAL SHEETS FOR ADDITIONAL INFORMATION.

SHADING OF ANY LUMINAIRE INDICATES CONNECTION TO

ALTERNATE POWER SOURCE (EMERGENCY, UPS, STANDBY, ETC.)

RECESSED CEILING LIGHT FIXTURE

SURFACE MOUNTED CEILING LIGHT FIXTURE

SURFACE MOUNTED CEILING LIGHT FIXTURE

RECESSED DOWNLIGHT LIGHT FIXTURE FOR WET LOCATIONS

RECESSED DOWNLIGHT LIGHT FIXTURE

SPEAKER/ENCLOSURE

SMOKE DETECTOR

GYPSUM BOARD, SEE ROOM FINISH SCHEDULE

1-HOUR RATED WALL ASSEMBLY, SEE DETAIL #10 / A502

CEILING FAN

CEILING DIFFUSER, SEE MECHANICAL SHEETS

RETURN GRILLE, SEE MECHANICAL SHEETS

ATTIC WALKWAY, SEE DETAIL 1 / - FOR CONSTRUCTION DETAIL

22" x 36" ATTIC ACCESS, SEE DETAIL #2 / A502

PROVIDE 1-HOUR F & T RATED HATCHES IN RATED CEILING ASSEMBLIES

CO CO

MULTI-CRITERIA DETECTOR

S C A L E : 11" = 1'-0"ATTIC WALKWAY

RECESSED LED EDGE-LIT EXIT SIGN

C

COMMS J-BOX

COAXIAL OUTLET

VOICE/DATA OUTLET

A

2 3 4

B

D

C

1 1 SEPT 2026 ADDENDUM #1

20"X30" 1-HOUR RATED SELF-CLOSING ACCESS HATCH 1

EXHAUST FAN, SEE MECHANICAL SHEETS

EQ

2' -0

TY

P

2'-0"

TYP

FO

F

AS

CI

A

FO

S

FO RAKE

FOS

RI

DG

E

VA

LL

EY

VALLEY

RI

DG

E

VALLEY VA

LL

EY

RI

DG

E

VALLEYVA

LL

EY

RI

DG

E

RIDGE

RI

DG

E

RIDGE

A501

VALLEY

TYP

EXHAUST FLUE,

SEE

MECHANICAL

SHEETS, TYP

A501

RAKE

TYP

A501

EAVE

TYP

ROOF OVERHANG

ROOF SLOPE 5:12

TYPICAL FOR ALL ROOFS.

ARROWS DENOTE

DIRECTION OF ROOF

SLOPE

WINDOW OR DOOR

HEADER, SEE STRUCTURAL

ROOF FRAMING PLAN, TYP

RIDGE CAP BY ROOFING

MANUFACTURER, TYP

WALLS SHOWN HALF

TONE, TYP

INTEGRAL COLOR

COATED PRE-FINISHED

SHEET METAL GUTTERS

AND DOWNSPOUTS, TYP

SEE DETAILS #6 & #7 /

A502

PLUMBING VENT STACK,

TYP, SEE PLUMBING PLAN

FOR ADDITIONAL

INFORMATION, SEE ROOF

PENETRATION DETAIL

#6 / A501

END ROOF PANEL TO BE

EQUAL AT ALL ROOFS, TYP

ROOF SLOPE 5:12

TYPICAL FOR ALL

ROOFS. ARROWS

DENOTE DIRECTION

OF ROOF SLOPE

METAL ROOF SYSTEM, TYP

SEE GENERAL NOTE #3

FULL SELF-ADHERED

UNDERLAYMENT, TYP

PLYWOOD SHEATHING

WITH RADIANT BARRIER,

SEE STRUCTURAL ROOF

FRAMING PLAN, TYP

A501

EAVE

TYP

A501

RAKE

TYP

A501

RIDGE

TYP

A501

RI

DG

E

A301

A301

A301

A302

A302

A302

(2) 8" SQUARE

VENTILATION

OPENINGS THROUGH

ROOF SHTG.

(2) 8" SQUARE

VENTILATION

OPENINGS

THROUGH SHTG.

(2) 8" SQUARE

VENTILATION

OPENINGS THROUGH

ROOF SHTG.

A131

ROOF PLAN

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V2

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

0\

A

1.

dw g S ep

6,

- 2 :2

7P M

PLAN

NORTH

SCALE: 3/16" = 1-0"

REFLECTED ROOF PLAN

GENERAL SHEET NOTES

ROOFING PRODUCT

PRESCRIPTIVE REQUIREMENTS FOR ROOFING PRODUCTS

ROOF PANELS SHALL MEET ONE OF THE FOLLOWING METRICS WHEN

TESTED ACCORDING TO CRRC-1:

1. THREE-YEAR AGED SOLAR REFLECTANCE OF NOT LESS THAN 0.20

AND EMISSIVITY OF NOT LESS THAN 0.75.

OR

2. THREE-YEAR AGED SOLAR REFLECTANCE INDEX OF NOT LESS THAN

16 WHEN CALCULATED ACCORDING TO ASTM E1980.

ROOF PANEL ENERGY PERFORMANCE PER CRRC-1

1. METAL ROOFING: HIGH RIBBED CLASS "A" STANDING SEAM METAL

ROOFING, DESIGN BASED ON AEP SPAN "DESIGN SPAN hp". INSTALL

PER MANUFACTURER'S SPECIFICATIONS.

2. SEE STRUCTURAL ROOF FRAMING SHEET.

3. CENTER ROOF PENETRATIONS BETWEEN SEAMS & INSTALL AT 4'-0"

MAX. FROM ALL RIDGES OR VALLEYS.

4. NOT ALL ROOF PENETRATIONS ARE SHOWN, SEE ELECTRICAL,

MECHANICAL AND PLUMBING SHEETS.

5. FLASH AND WATERPROOF ALL REQUIRED ROOF PENETRATIONS

INCLUDING, BUT NOT LIMITED TO PLUMBING VENT, WATER HEATER

VENT, FURNACE VENT, KITCHEN EXHAUST VENT. REWORK

CONFIGURATION AS REQUIRED TO SUIT PROJECTION AND SNOW

LEVELS.

6. INSTALL RIB STIFFENERS AT ALL VALLEYS AND EAVES.

7. ALL RIBS/BATTENS SHALL RECEIVE SEALANT TAPE ALONG ENTIRE

LENGTH.

8. APPLY EXTRA LAYER OF MODIFIED BITUMEN UNDERLAYMENT IN

VALLEYS EXTENDING 24" FROM CENTER LINE.

9. PROVIDE OPENINGS IN SHEATHING BETWEEN ROOF ZONES TO

ALLOW UNOBSTRUCTED AIRFLOW. SEE STRUCTURAL FOR

MAXIMUM OPENING SIZES ALLOWED.

10. AT CALIFORNIA FRAMING, PROVIDE OPENINGS IN SHEATHING

BETWEEN ATTIC AREAS FOR AIRFLOW.

ROOF COVERING:

WHERE THE ROOF PROFILE ALLOWS A SPACE BETWEEN THE ROOF

COVERING AND ROOF DECKING,

THE SPACE SHALL BE CONSTRUCTED TO RESIST THE INTRUSION OF

FLAMES AND EMBERS, BE FIRESTOPPED WITH APPROVED

MATERIALS OR HAVE ONE LAYER OF MINIMUM 72 POUND

MINERAL-SURFACED

NON-PERFORATED CAP SHEET COMPLYING WITH ASTM D3909

INSTALLED OVER THE COMBUSTIBLE DECKING.

ROOF VALLEYS:

WHERE VALLEY FLASHING IS INSTALLED, THE FLASHING SHALL NOT

BE LESS THAN NUMBER 26 GAGE GALVANIZED SHEET

CORROSION-RESISTANT METAL INSTALLED OVER NOT LESS THAN

ONE LAYER OF MINIMUM 72 POUND MINERAL-SURFACE

NON-PERFORATED CAP SHEET COMPLYING WITH ASTM D3909, AT

LEAST 36 INCH WIDE RUNNING THE FULL LENGTH OF THE VALLEY.

ROOF GUTTERS:

ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT

THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER.

ATTIC VENTILATION:

ROOF ATTIC VENTS SHALL RESIST THE INTRUSION OF FLAME AND

EMBERS INTO THE ATTIC AREA OF

THE STRUCTURE OR SHALL BE PROTECTED BY

CORROSION-RESISTANT, NON-COMBUSTIBLE WIRE

MESH WITH OPENINGS A MINIMUM OF 1/16" AND SHALL NOT

EXCEED 1/8".

WUI REQUIREMENTS

ROOF PANEL NOTES

1. ROOF PANELS ARE 18" WIDE AND SNAP-LOCK INTO CLIPS THAT

CONNECT PANELS TOGETHER ALONG OVERLAPPING PANEL EDGE

SEAMS.

2. FIRST CLIP IS 8" MAX FROM FACE OF FASCIA.

3. CLIPS ARE THEN SPACED 24" MAX OC UP TO THE RIDGE.

4. CLIP FASTENERS: QTY 2 PER CLIP, #12, HWH, 5/16" HEX, 1"

LENGTH, GIMLET POINT.

5. FIX PANELS AT RIDGE WITH 3 #12 x 1" SCREWS PER PANEL WITH 1"

MIN EDGE DISTANCE.

6. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

ROOF VENTING CALCS

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

ROOF VENTING TO ACHIEVE 1/300 WITH 50% HIGH AND 50% LOW VENTING

AREA 1A: 2,580 SF / 300 = 8.6 SQ. FT. = 1238.4 SQ. IN. TOTAL AREA REQUIRED

1238.4/ 2 = 619.2 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 619.2 SQ. IN. REQUIRED AT RIDGE VENT

115 L.F. x 12 = 1380 SQ. IN.

x 0.62 OPEN FREE AREA = 855.6 SQ. IN. AT RIDGE VENT

LOW VENTING AREA MINIMUM 619.2 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

855.6 SQ. IN. / 12.6 SQ. IN. = 68 BLOCKS EVENLY DISTRIBUTED

SOFFIT VENTS: 60 L.F. x 12 = 720 x 2" WIDE VENT = 1440 SQ. IN.

x 0.62 FREE AREA = 892.8 SQ. IN.

AREA 1B: 444 SF / 300 = 1.48 SQ. FT. = 213.12 SQ. IN. TOTAL AREA REQUIRED

213.12 / 2 = 106.6 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 106.6 SQ. IN. REQUIRED AT RIDGE VENT

24 L.F. x 12 = 288 SQ. IN.

x 0.62 OPEN FREE AREA = 179 SQ. IN.

LOW VENTING AREA MINIMUM 106.6 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

179 SQ. IN. / 12.6 SQ. IN. = 15 BLOCKS EVENLY DISTRIBUTED

SOFFIT VENTS: 29 L.F. x 12 = 348 x 2" WIDE VENT = 696 SQ. IN.

x 0.62 FREE AREA = 431.5 SQ. IN.

AREA 1C:149 SF / 300 = 0.50 SQ. FT. = 72 SQ. IN. TOTAL AREA REQUIRED

72 / 2 = 36 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 36 SQ. IN. REQUIRED AT RIDGE VENT

6.3 L.F. x 12 = 75.6 SQ. IN.

x 0.62 OPEN FREE AREA = 47 SQ. IN.

LOW VENTING AREA MINIMUM 36 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

47 SQ. IN. / 12.6 SQ. IN. = 4 BLOCKS TOTAL (2 EA SIDE)

SOFFIT VENTS: 20.4 L.F. x 12 = 244.8 x 2" WIDE VENT = 489.6 SQ. IN.

x 0.62 FREE AREA = 304 SQ. IN.

AREA 2: 539 SF / 300 = 1.80 SQ. FT. = 258.72 SQ. IN. TOTAL AREA REQUIRED

258.72 / 2 = 129.36 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 129.36 SQ. IN. REQUIRED AT RIDGE VENT

19.4 L.F. x 12 = 232.8 SQ. IN.

x 0.62 OPEN FREE AREA = 144.34 SQ. IN.

LOW VENTING AREA MINIMUM 129.36 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

144.34 SQ. IN. / 12.6 SQ. IN. = 12 BLOCKS TOTAL (6 EA SIDE)

SOFFIT VENTS: 34 L.F. x 12 = 408 x 2" WIDE VENT = 816 SQ. IN.

x 0.62 FREE AREA = 505 SQ. IN.

AREA 3: 1010 SF / 300 = 3.37 SQ. FT. = 484.8 SQ. IN. TOTAL AREA REQUIRED

485 / 2 = 242.5 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 242.5 SQ. IN. REQUIRED AT RIDGE VENT

36 L.F. x 12 = 432 SQ. IN.

x 0.62 OPEN FREE AREA = 267.8 SQ. IN.

LOW VENTING AREA MINIMUM 242.5 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

268 SQ. IN. / 12.6 SQ. IN. = 22 BLOCKS TOTAL (11 EA SIDE)

SOFFIT VENTS: 72 L.F. x 12 = 864 x 2" WIDE VENT = 1728 SQ. IN.

x 0.62 FREE AREA = 1071 SQ. IN.

AREAS 4 & 5: 46 SF / 300 = 0.15 SQ. FT. = 22 SQ. IN. TOTAL AREA REQUIRED

22 / 2 = 11 SQ. IN. REQUIRED FOR HIGH & LOW VENTING

HIGH VENTING AREA MINIMUM 11 SQ. IN. REQUIRED AT RIDGE VENT

5.5 L.F. x 12 = 66 SQ. IN.

x 0.62 OPEN FREE AREA = 41 SQ. IN.

LOW VENTING AREA MINIMUM 11 SQ. IN. REQUIRED:

VENT BLOCKING - 4 HOLES @ 2" DIA. = 12.6 SQ. IN.

41 SQ. IN. / 12.6 SQ. IN. = 4 BLOCKS TOTAL (2 EA SIDE)

SOFFIT VENTS: 15 L.F. x 12 = 180 x 2" WIDE VENT = 360 SQ. IN.

x 0.62 FREE AREA = 223 SQ. IN.

ROOF VENTING REQUIREMENTS

MINIMUM ROOF VENTING FOR EACH BUILDING ROOF AREA:

AREA 1A: CONTINUOUS HIGH VENTING AT RIDGE VENT (DETAIL 3 / A501 TYP)

VENTED EAVE BLOCKING: 68 BLOCKS EVENLY DISTRIBUTED

CONTINUOUS SOFFIT VENTS (DETAIL 1 / A501 TYP)

AREA 1B: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 15 BLOCKS EVENLY DISTRIBUTED

CONTINUOUS EAVE SOFFIT VENTS

AREA 1C: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 4 BLOCKS (2 BLOCKS EA SIDE) EVENLY SPACED

CONTINUOUS EAVE SOFFIT VENTS

AREA 2: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 12 BLOCKS (6 BLOCKS EA SIDE) EVENLY SPACED

CONTINUOUS EAVE SOFFIT VENTS

AREA 3: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 22 BLOCKS (11 BLOCKS EA SIDE) EVENLY SPACED

CONTINUOUS EAVE SOFFIT VENTS

AREA 4: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 4 BLOCKS (2 BLOCKS EA SIDE) EVENLY SPACED

CONTINUOUS EAVE SOFFIT VENTS

AREA 5: CONTINUOUS HIGH VENTING AT RIDGE VENT

VENTED EAVE BLOCKING: 4 BLOCKS (2 BLOCKS EA SIDE) EVENLY SPACED

CONTINUOUS EAVE SOFFIT VENTS

A

2 3 4

B

D

C

1 SEPT 2026 ADDENDUM #1

SCALE: N.T.S.

ROOF VENTING KEYPLAN

ROOF VENTING AREA #4

ROOF VENTING AREA #1C

ROOF VENTING AREA #1A

ROOF VENTING AREA #2

ROOF VENTING AREA #3

ROOF VENTING AREA #5

ROOF VENTING AREA #1B

FINISH GRADE AND ACCESSIBLE PATH OF TRAVEL (SEE GENERAL NOTES THIS SHEET AND SITE PLAN FOR CONTINUATION), TYP

SMOKING IS PROHIBITED

WITHIN 20 FEET OF MAIN

ENTRANCES, EXITS AND

OPERABLE WINDOWS

BARRACKS

SMOKING IS PROHIBITED

WITHIN 20 FEET OF MAIN

ENTRANCES, EXITS AND

OPERABLE WINDOWS

A501

+0'-0" FINISHED FLOOR

+15'-7" TOP OF RIDGE

+13'-6" TOP OF RIDGE

RESTRICTED AREA

CAL FIRE PERSONNEL ONLY

RESTRICTED AREA

CAL FIRE PERSONNEL ONLY

+16'-10" TOP OF RIDGE

+11'-6" TOP OF RIDGE

MAIN ENTRANCE WITH SIGNS

6" HIGH RAISED STAINLESS

STEEL LETTERS, TYP

+9'-0" TOP PLATE

TYPICAL OF ALL

ROOF PLANES

SCALE: 3/16" = 1'-0"A FRONT SIDE ELEVATION

RIDGE

TYP

SEE OTHER ELEVATIONS FOR TYPICAL NOTES AND DIMENSIONS

CONTROL JOINT, TYP.

SEE DETALS #10 & #14/ A501

HORIZONTAL REVEAL - CHANNEL

SCREED: FRY REGLET #PCS-75-200,

CENTERED AT 3'-6" AFF, TYP

SEE DETAIL #11 / A501

A503

A501

1'-3"

10'-0" 6'-0" 6'-0"EQEQ

3' -3

4'-0"10'-0" 4'-10"

1'-3"

2' -6

TY

P

PREFINISHED STANDING SEAM METAL ROOF, TYP

CONCRETE SLAB SLOPED AWAY FROM BLDG, TYP OF ALL

FLATWORK AND PAVING AROUND BUILDING

SMOKING IS PROHIBITED

WITHIN 20 FEET OF MAIN

ENTRANCES, EXITS AND

OPERABLE WINDOWS

RESTRICTED AREA

CAL FIRE PERSONNEL ONLY

SCALE: 3/16" = 1'-0"B LEFT SIDE ELEVATION

A503

HEAD

TYP

A503

JAMB

SIM

THRESHOLD

TYP

A503

THRU ROOF PLUMBING VENT, TYP - SEE MECHANICAL AND 9/A501

INTEGRAL COLOR COATED PREFINISHED METAL GUTTER, TYP

INTEGRAL COLOR COATED PREFINISHED GALVANIZED SHEET METAL

DOWNSPOUT TO CONNECT TO PIPE AND DAYLIGHT AT FACE OF

CURB OR PAVEMENT, SEE CIVIL PLAN FOR TERMINATION

CONFIGURATION, TYP SEE GENERAL SHEET NOTES

SEE OTHER ELEVATIONS FOR TYPICAL NOTES AND DIMENSIONS

3" REFLECTIVE TEXT IN CAL FIRE RED STATING "FIRE RISER INSIDE"

CENTERED ON DOOR

11'-0" 11'-10" 11'-9" 3'-0" 6'-0" 12'-0" +/-3'-0" 10'-0"

4'-0" 2'-0" 4'-0"2'-0"

4' -6

6" TYP

1' -2

SMOKING IS PROHIBITED

WITHIN 20 FEET OF MAIN

ENTRANCES, EXITS AND

OPERABLE WINDOWS

SMOKING IS PROHIBITED

WITHIN 20 FEET OF MAIN

ENTRANCES, EXITS AND

OPERABLE WINDOWS

RESTRICTED AREA

CAL FIRE PERSONNEL ONLY

SCALE: 3/16" = 1'-0"C REAR SIDE ELEVATION

+0'-0" FINISHED FLOOR

+14'-2" TOP OF RIDGE

+16'-10" TOP OF RIDGE

+9'-0" TOP PLATEHEAD

TYP

SILL

TYP

JAMB

TYP

SEE OTHER ELEVATIONS FOR TYPICAL NOTES AND DIMENSIONS

6x6 POST, SEE STRUCTURAL

SHEETS, TYP

6" x 6" GALVANIZED METAL DRYER VENT EXHAUST WALL CAP DISCHARGE, SEE MECHANICAL 8 A503

A503

A501

A501

A503

6'-0" 6'-0"EQEQ 14'-4 1/2" 18'-0"

1' -9

"3' -3

LIGHT FIXTURE, TYP

SEE ELECTRICAL PLANS

FASCIA, TYP

SCALE: 3/16" = 1'-0"D RIGHT SIDE ELEVATION SEE OTHER ELEVATIONS FOR TYPICAL NOTES AND DIMENSIONS

6" CURBED FOOTING AT WALLS, TYP

SEE STRUCTURAL

+0'-0" FINISHED FLOOR

+9'-0" TOP PLATE

+11'-4" TOP OF RIDGE

2'-0"

OVERHANG,

TYP

+12'-6" TOP OF RIDGE

A501

A501

RAKE

TYP

EAVE

TYP

6" H x 6" W x 10" L CURB - PROTECTIVE BARRIER FOR

KICKER, AT EACH SIDE OF ENTRY PORCH, SEE 4/A504.

KICKER ANCHORED INTO

EXTENDED TRIM, SEE STRUC

EXTENDED TRIM, SEE 5/A503

10'-3 1/2" 8'-11 1/2" 10'-0" 12'-0" 10'-0" EQEQ

8' -6

4'

-6

2'-0"

TYP

2'-0"

TYP

11'-10" 11'-0"11'-9"

A201

EXTERIOR ELEVATIONS

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V2

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

4\

A

1.

dw g S ep

6,

- 8 :1

6A M

GENERAL SHEET NOTES

1. EXTERIOR SIDING SHALL BE CEMENT PLASTER SYSTEM.

2. FASCIA SHALL BE 2" x 8" REDWOOD, PAINTED TO MATCH COLOR OF FASCIA ON ADJACENT EXISTING BUILDING.

SEE STRUCTURAL SHEETS.

3. CONTROL JOINTS ARE DIMENSIONED FROM ADJACENT JOINT OR EDGE OF WALL. EACH INTERIOR WALL CORNER

SHALL HAVE A CONTROL JOINT, SEE 10/A503.

4. TRIM SHALL BE FIBER CEMENT BY JAMES HARDIE (RUSTIC GRAIN) 5/4 x 3.5" PAINTED TO MATCH COLOR OF

SOFFIT ON ADJACENT EXISTING BUILDING. EXTEND ALL TRIM TO CONCEAL SUB FRAMING.

5. ALL BEAMS SHALL EXTEND 3" BEYOND FACE OF POST. BEAMS AND POSTS SHALL BE PAINTED TO MATCH TRIM.

COVER BEAM ENDS WITH 5" GALVANIZED FLASHING BEAM CAPS, PAINTED TO MATCH BEAM.

6. ALL EXPOSED METAL FLASHING TO BE PRIMED AND PAINTED TO MATCH THE OBJECT BEHIND IT.

7. WALL PENETRATIONS LARGER THAN 1/2" TO BE FILLED WITH EXPANDING FOAM INSULATION AND COVERED WITH

ESCUTCHEON PLATE.

8. PENETRATIONS 1/2" AND SMALLER TO BE FILLED WITH EXPANDING FOAM INSULATION AND FINISHED WITH

BACKER ROD AND SEALANT.

9. APPLY LIQUID APPLIED WATER/AIR BARRIER TO THE STRUCTURAL SHEATHING.

10. STANDING SEAM METAL ROOFING SHALL BE OF COOL ROOF TO MATCH COLOR OF ROOF ON ADJACENT EXISTING

BUILDING.

11. GUTTERS SHALL BE GALVANIZED SHEET METAL SPACED 25'-0" MAX, SEE DETAILS #6 & #7 / A502. GUTTERS

SHALL BE PAINTED TO MATCH COLOR OF GUTTERS ON ADJACENT EXISTING BUILDING.

12. TERMINATE DOWNSPOUTS ONTO SPLASH BLOCKS, TYP.

13. LOUVERED ATTIC VENT(S) EITHER ONE OR TWO AS SHOWN SHALL BE 14" X 18", SEE LOUVER SCHEDULE TAG L1.

SEE DETAILS #15A & #15B / A503

14. 6" HIGH LETTERING FOR "BARRACKS" SIGNS SHALL BE OF FONT TYPE ARIAL-BOLD WITH A WIDTH FACTOR OF 1.00.

15. ABOVE DOORWAYS, PROVIDE PLASTER CEMENT COATED 1"x 3" STUCCO FOAM SHAPE AS VISUAL TRIM. EXTEND 6"

BEYOND FRAMED OPENING, TYP.

16. NOT USED.

17. NOT USED.

18. COORDINATE ALL PLUMBING ROOF PENETRATION WITH MECHANICAL SHEETS, INSTALL WATERPROOF FLASHING

AS REQUIRED.

19. NOT USED.

20. OUTDOOR MECHANICAL UNITS AND OTHER BUILDING SYSTEMS NOT SHOWN IN THESE ELEVATION VIEWS.

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

1 SEPT 2026 ADDENDUM #1

FE

R

30" x 48" CLR 30" x 48" CLR

" x

8"

C

LR

" x

8"

C

LR

" x

8"

C

LR

" x

8"

CL

R

" C

LR

36" CLR

36" CLR

24" CLR

24" CLR

" C

LR

KITCHEN

STOR

PANTRY

A

F

A402

BD

A402

E

C

A402

ONLY COUNTERTOP

FIELD JOINT ACCEPTED

A

D

C

B

A403

REFRIGERATOR FREEZERREFRIGERATOR

5'-3" CLR

4' -2

" C

LR

6' -1

1"

1' -6

" T

YP

1' -0

BDRM 5

A

B

C

D

A401

SHELF, DRAWER, CUBBY UNIT IN

ACCESSIBLE ROOM SHALL BE

MOUNTED TO BE REMOVABLE

60" CLR

WASHER

DRYER

" x

8"

C

LR

60" x 54" CLR

30" x 48" CLR 30" x 48"

CLR

30" x 48" CLR

30" x 48" CLR

LAUN

A

D

C

B

A403

C DA

" M

IN

C

LR

" M

AX

20" MIN NET

CLEAR OPNG

WIDTH

" M

IN

N

ET

CL

EA

R

OP

NG

HE

IG

HT

WALL MOUNTED TASK LAMP,

SEE ELEC SHEETS.

CENTER OVER EXTENDED JAMB TRIM

10" DEEP WALL MOUNTED

SHELF W/ DRAWERS & CUBBY,

SEE DETAIL #8 / A502

ELECTRICAL AND TELCO OUTLETS,

SEE ELEC SHEETS, TYP

SEE ROOM FINISH SCHEDULE,

TYP

5 SQ. FT. MIN NET CLEAR OPENING,

SEE WINDOW SCHEDULE FOR

FURTHER INFORMATION

B

9 1/4"

TYP

LOCKER, SEE SHEET A405, TYP

BATHRM

A504

A502

EF

A404

C

B

A

D

A404

48" MIN CLR

" M

IN

C

LR

MIN CLR

FOF

2 - 2x4 W/ 1/2" GAP WALL

5' -7

/2

BE

TW

EE

N

ST

UD

S)

3' -6

TY

P)

18"

DEPRESSED SLAB IN

SHOWER AREA, TYP.

SEE STRUC AND 5/A502

A504

60" CLR

30" x 48" CLR

30" x 48" CLR

60" x 54" CLR 60" x 56" CLR

5'-4 1/2" (BETWEEN STUDS)

5'-0" MIN CLEAR FOF

GRAB BAR, SEE DETAIL

#9 / A504

1.9% MIN SLOPE

2% MAX SLOPE TOWARDS

LINEAR DRAIN, TYP

FOLDING SEAT, SEE

DETAIL #1 / A504

(3 0"

M

IN

F

OF

" M

IN

" M

AX

A401

ENLARGED FLOOR PLANS

AND INTERIOR ELEVATIONS

M. HEINTZ

M. HEINTZ

A. ECCLESTON

1"

SHEET NUMBER

SHEET TITLE:

JOB NUMBER:

FILE DATE:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

FRESNO

AIR ATTACK BASE

C130 BARRACKS

2311 N CLOVIS AVENUE

FRESNO, CALIFORNIA 93727

FRESNO COUNTY

DATENO. DESCRIPTION

PL

OT

D

AT

E:

PR

OJ

EC

T

PA

TH

A

REVISIONS

VE

R

. 2

BCDEFGHIJKL

ABCDEFGHIJKL

DSA Approval

OSFM Approval

TECHN I CAL SERV I CES Capital Out lay Real Estate Surveying Architecture & Engineering C ons tru ct ion Ma na ge rs

Va ul t s

1131 S STREET, SACRAMENTO, CA 95811-2460

V3

C :\U se rs

\D co ro na

\A pp

D at a\ Lo ca l\T em p\

A cP ub lis h_

0\

A

1.

dw g S ep

6,

- 1 :1

4P M

SCALE: 1/2" = 1'-0"1 ENLARGED PLAN

SCALE: 1/2" = 1'-0"4 ENLARGED PLAN

SCALE: 1/2" = 1'-0"2 ENLARGED PLAN

1. FIELD VERIFY ALL DIMENSIONS BEFORE FABRICATION.

2. COORDINATE WITH ALL POSSIBLE OBSTRUCTIONS

INCLUDING, BUT NOT LIMITED TO LIGHT FIXTURES,

SMOKE DETECTORS, SPEAKERS AND MECHANICAL

REGISTERS/GRILLS..

3. SIGNAGE / ROOM IDENTIFICATION, SEE SHEET A500.

4. DIMENSIONS INDICATED AS "MIN. CLR." ARE TO FACE OF

FINISH.

5. SEE SHEET A602 FOR ROOM FINISH SCHEDULE.

6. ALL EXPOSED METAL SHALL BE PRIMED AND PAINTED.

7. VERIFY SIZES AND REQUIRED WORKING CLEARANCES OF

ALL EQUIPMENT AND APPLIANCES PRIOR TO MILLWORK

FABRICATION.

8. SEE SHEET A500 FOR ADDITIONAL ACCESSIBLE

CLEARANCES.

GENERAL SHEET NOTES

S C A L E : 11/2" = 1'-0"BEDROOM INTERIOR ELEVATIONS

A . E

. E C C L E S T ON

C 90716

C IV IL

R

EG

IS

T E

R ED P R O F E S S IO NA L ENG

IN

EER

S T A T E O F C A L IF O R NIA

SCALE: 1/2" = 1'-0"3 ENLARGED PLAN

1 SEPT 2026 ADDENDUM #1