B7362 HazMat Report.pdf

PDF 8 MB Posted

Attached to
Demolition Services At JBSA LAK/ LAK Chapman Annex
Solicitation number
FA301626R0033
Issued by

About this file

This is a Limited Hazardous Materials Survey report for Building 7362 located at 1359 Tinker Avenue, JBSA – Lackland Air Force Base, Texas 78236, prepared by TTL, Inc. for the 802 CES/CENME (Civil Engineer Squadron), Execution Support at JBSA – Fort Sam Houston. The survey was conducted on January 21, 2026, and the report was completed on March 3, 2026 (Project No. 26-09-00191.00).

The survey encompasses four primary assessments: asbestos-containing materials (ACM), lead-based paint (LBP), hazardous components, and mold assessment. The ACM survey identified 102 bulk samples collected from interior and exterior areas, with analytical results showing asbestos (primarily 2% Chrysotile) in drywall joint compounds, textures, ceramic tile mortars, pipe insulation mastic, vinyl composition tile, and cementitious paneling throughout multiple floors and the basement. The LBP survey of 17 paint chip samples identified one sample exceeding the 0.5% lead concentration threshold: green paint on a wood door in the basement (2.126% lead by weight, approximately 25 SF). The hazardous components survey identified approximately 110 fluorescent lamp ballasts (with approximately 10% disassembled and labeled "No PCBs"), approximately 110 mercury-containing fluorescent tube bulbs, 19 CFLs, one pole-mounted transformer with unknown PCB status, and approximately 10 illuminated exit signs containing Nickel-Cadmium rechargeable backup batteries. The mold assessment revealed visible water damage and mold growth in multiple areas including central rooms, dorm room closets, mechanical room door, restroom ceilings and hallways, and the first-floor stairwell. Indoor air samples showed elevated mold spore concentrations compared to outdoor control samples, with relative humidity readings significantly above recommended levels (72.9% to 87.2% compared to the recommended <65%), attributed to faulty building seals and non-functioning air conditioning. The report recommends that all ACMs impacted by renovation or demolition be removed by a TDSHS licensed contractor with third-party air monitoring, proper disposal of all mercury-containing bulbs and universal waste items at EPA-approved facilities, and remediation of water intrusion issues and mold contamination.

View the file

Other files

File Type Posted
jbsanantonio7_UAR_20240920.pdf PDF
B140 HazMat Report.pdf PDF
B7561 HazMatRprt.pdf PDF
B2988 HazMatRprt.pdf PDF
PWS CTO MultiFacDemo JBSA_LAK_19May_FINAL.docx DOCX document
Outage Request.pdf PDF
B4395 HazMatRprt.pdf PDF
B5584 HazMat Report.pdf PDF
Solicitation Amendment - FA301626R00330001.pdf PDF
Solicitation - FA301626R0033.pdf PDF
B2989 HazMatRprt.pdf PDF
WD-2015-5253 Rev 29.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Limited Hazardous Materials Survey

Building 7362 1359 Tinker Avenue

JBSA – Lackland Air Force Base, Texas 78236

Prepared for:

802 CES/CENME, Execution Support

2250 Engineer Street - Building 4196

JBSA - Fort Sam Houston, Texas 78234

Prepared by:

TTL, Inc.

17215 Jones Maltsberger Road, Suite 101

San Antonio, Texas 78247

Project No. 26-09-00191.00

March 3, 2026

17215 Jones Maltsberger Rd., Ste. 101

San Antonio, TX 78247

210.888.6100 www. TTLUSA.com

Asbestos Consultant Agency No. 100550 ▪ Lead Firm No. 2110644 ▪ Mold Assessment Company No. ACO1228

March 3, 2026

Mr. Eraldo David Martinez

802 CES/CENME, Execution Support (JBSA - 802 CES/CENME, EXECUTION SUPPORT)

2250 Engineer Street, Building 4196

JBSA - Fort Sam Houston, Texas 78234

P: 210.295.4727

E: eraldo.martinez@us.af.mil

RE: Limited Hazardous Materials Survey Report

Building 7362

1359 Tinker Avenue

JBSA – Lackland Air Force Base, Texas 78236

TTL Project No. 26-09-00191.00

Dear Mr. Martinez, TTL, Inc. (TTL) is pleased to submit this Hazardous Materials Survey report for Building 7362 located at 1359 Tinker Avenue, JBSA – Lackland Air Force Base, Texas, herein referred to as the “Site”. It should be noted that that JBSA – Lackland Air Force Base is considered a National Standards for

Hazardous Air Pollutants (NESHAP) facility due to limited access to buildings and badging requirements.

Scope of Services

TTL was retained to conduct an asbestos-containing materials (ACM) survey, lead-based paint (LBP) inspection, a hazardous components survey, and a mold assessment.

The purpose of this survey was to determine the presence, quantity, and condition of suspect ACM, LBP, hazardous components, and mold growth located at the Site. The field work for the hazardous materials survey was conducted on January 21, 2026.

Report

Laboratory results, sample location maps, and photographs are included in the appendices following the report. This report is divided into four (4) sections, which include ACM Survey, LPB Survey, Hazardous Components Survey, and a Mold Assessment. A photo log is provided in Appendix H.

Applicable licenses or certifications are provided in Appendix I.

Limitations

Observations and sampling performed during this site assessment are likely to be reasonable assessment of the conditions in the areas assessed at the Site. Environmental measurements within a building can vary from day to day and represent a snapshot on the day and time of the assessment.

This assessment did not include destructive sampling to check behind wallpaper, wall cavities or concealed areas for hazardous materials.

This report is intended for the sole use and benefit of JBSA - 802 CES/CENME, Execution Support and may not be relied upon by any other party without express permission of TTL.

TTL has no knowledge of any hidden or unapparent or adverse environmental conditions of the property, including the presence of hidden mold, hazardous wastes, toxic substances, etc. TTL makes http://www/

JBSA Lackland Air Force Base – Building 7362 –Hazardous Materials Survey March 3, 2026

TTL Project No. 26-09-00191.00 Page 2 of 16

© 2026, TTL, Inc. Passion | Purpose | Principles no guarantees or warranties, express or implied, regarding the condition of the property. This report is not an environmental assessment of the property.

This report and associated conclusions are based on the visible conditions of the inspected areas and materials. TTL reserves the right to revise opinions and conclusions if necessary and warranted by the discovery of new or additional circumstances. This report is specific and limited in nature and shall not be relied on as a statement that all Hazardous Materials have been identified and that more exists beyond the visibly accessible areas.

Closing

TTL appreciates the opportunity to provide environmental consulting services to JBSA - 802

CES/CENME, EXECUTION SUPPORT on this phase of the project. Should you have any questions, or require additional information regarding the Hazardous Materials Survey, please call us at your convenience.

Respectfully submitted, Nicolas Espino Osanna Carrasco

Project Professional Sr. Project Manager

TDSHS Lead Risk Assessor 2071258 TDSHS Lead Project Designer 2090091

TDLR Mold Assessment Consultant MAC1943 TDLR Mold Assessment Consultant MAC1587

TDSHS Asbestos Inspector 603646

TTL Project No. 26-09-00191.00 Page 3 of 15

© 2026, TTL, Inc. Passion | Purpose | Principles

TABLE OF CONTENTS

1.0 ASBESTOS-CONTAINING MATERIAL SURVEY

1.1 Sampling Methods

1.2 Laboratory Analysis

1.3 Findings

1.4 Asbestos Recommendations

2.0 LEAD BASED PAINT SURVEY

2.1 Sampling Methods

2.2 Paint Chip Sample Summary

2.4 Lead Recommendations

3.0 LIMITED HAZARDOUS COMPONENTS SURVEY

3.1 Purpose and Scope

3.2 Polychlorinated Biphenyls

3.3 Mercury

3.4 Additional Hazardous Components

4.0 LIMITED MOLD ASSESSMENT

4.1 LIMITED MOLD ASSESSMENT METHODS

4.1.1 Building Materials Moisture Assessment

4.1.2 Indoor Air Parameters

4.1.3 Bioaerosol Samples

4.2 MOLD ASSESSMENT FINDINGS

4.2.1 Visual Observations and Building Materials Moisture Assessment

4.2.2 Indoor Air Parameters

4.2.2 Bioaerosol Sample Results

4.3 MOLD ASSESSMENT CONCLUSIONS

APPENDIX A: SAMPLE LOCATION MAPS

APPENDIX B: LABORATORY RESULTS

APPENDIX C: SITE PHOTOGRAPHS

APPENDIX D: LICENSES AND CERTIFICATIONS

TTL Project No. 26-09-00191.00 Page 4 of 15

1.0 ASBESTOS-CONTAINING MATERIAL SURVEY

The limited asbestos survey was conducted on January 21, 2026, by Texas Department of State Health

Services (TDSHS) licensed Asbestos inspectors Deborah Salahuddin (license number 603987), and

Nicolas Espino (license number 603646).

1.1 Sampling Methods

TTL performed the limited asbestos inspection survey in general accordance with TDSHS

Administrative Code Title 25, Part 1, Chapter 296, Texas Asbestos Health Protection Rules (TAHPR), as well as the United States Environmental Protection Agency (USEPA) National Standards for

Hazardous Air Pollutants (NESHAP). Approximate quantities of suspect materials were estimated by field measurements. The condition (e.g., good, damaged, significantly damaged) and friability (i.e., easily crumbled, pulverized, or reduced to powder by hand pressure) of suspect ACM was noted for each material. The friability of each sampled material was determined by hand-touch.

• Surfacing materials, including spray-applied or troweled on wall/ceiling coatings,

• Thermal system insulation (TSI), including pipe insulation, duct insulation, boiler lagging and

• Miscellaneous materials, including ceiling panels/tiles, floor tiles and mastic, gaskets (if accessible), and wallboard/joint compound.

Suspected ACMs were grouped into homogeneous areas (i.e., a material that is uniform in texture, color, date of application, use or system, and appears identical in every other aspect). Homogeneous areas were determined by the TDSHS licensed Asbestos Inspector(s) based upon date of installation and uniformity or color and texture. Fiberglass, foam glass, rubber or wood products, plastic products, glass and steel were not sampled since they are not considered suspect ACM.

1.2 Laboratory Analysis

A total of one-hundred-two (102) bulk samples were collected from the selected areas of the interior and exterior of the building. Samples were deposited in secure containers for transport to the analytical laboratory.

Bulk suspect asbestos samples were submitted under secure chain of custody and were analyzed utilizing Polarized Light Microscopy (PLM), following the USEPA PLM Method EPA-600/R-93/116. The bulk samples were analyzed by Moody Labs (Moody), in Farmers Branch, Texas. Moody is accredited by the National Institute of Standards and Technology National Voluntary Laboratory Accreditation

Program (NVLAP No. 102056-0) and licensed by TDSHS (license number 300084).

A summary of TTL’s asbestos sampling, including analytical results, sample number, material descriptions, sample locations, material condition, friability and estimated quantities is provided in

Table 1 below.

TTL Project No. 26-09-00191.00 Page 5 of 15

TABLE 1: Asbestos Sample Results Summary

Building 7362

1359 Tinker Avenue, JBSA Lackland Air Force Base, San Antonio, Texas 78236

Sample

No.

Suspect Material Sample Location Asbestos %

Estimated

Quantities

Friability

(F/NF)

Condition

1-01, 02,03

Popcorn Ceiling

Textured Drywall

System

2nd Floor - North

Dorm Room, South

Hallway, South

Dorm Room

JC: 2% Chrysotile

TX: 2% Chrysotile

5,000 SF F SD

2-01, 02,03

Perlite Drywall

Texture and Joint

Compound

2nd Floor - South

Dorm Rooms, North Dorm Room

JC: 2% Chrysotile

TX: 2% Chrysotile

10,000 SF

F D

3-01, 02,03

Wallpaper and Joint

Compound

2nd Floor - South

Dorm Room, North

Restroom, North

Dorm Room

JC: 2% Chrysotile F SD

4-01, 02,03

Blue Cove Base / Tan

Mastic

2nd Floor - Central

Room, North

Stairwell, North

Dorm Room

None Detected N/A NF D

5-01, 02,03

Grey Cove Base / Tan

Mastic

2nd Floor - South

Hallway None Detected N/A NF D

6-01, 02,03 Tan Carpet Mastic

2nd Floor - Central

Room, North

Hallway, North

Dorm Room

None Detected N/A NF D

7-01, 02,03

4” Ceramic Wall Tile

Grout & Thin set

2nd Floor - North &

South Restroom MR: 2% Chrysotile 1,000 SF NF G

8-01, 02,03

1” Ceramic Floor Tile

Grout & Thin set

2nd Floor - North &

South Restroom None Detected N/A NF D

9-01, 02,03 Mastic on HVAC

2nd Floor -

Mechanical Room None Detected N/A NF D

10–01, 02, 03

Pipe Insulation /

Wrap

2nd Floor -

Mechanical Room None Detected N/A F SD

11-01, 02,03 Sink Under Coating

2nd Floor - Central

Room Sink 2% Chrysotile 1 Sink NF G

12-01, 02,03 Stair Tread

North & South

Stairwells None Detected N/A NF G

13-01, 02,03

Drywall System with

Lace Texture

North & South

Stairwells

JC: 2% Chrysotile

TX: 2% Chrysotile

2,000 SF F D

14-01, 02,03

Cementitious

Paneling

2nd Floor Storage

Room, 1st Floor

Mechanical Room, 15% Chrysotile 500 SF NF D

15-01, 02,03

Popcorn Textured

Drywall Ceiling

System

1st Floor - North

Hallway, Central

Room, South

Hallway

JC: 2% Chrysotile 5,000 SF F SD

16-01, 02,03

Perlite Textured

Drywall System

1st Floor - North

Dorm Rooms, South Dorm Room

TX: 2% Chrysotile 7,500 SF F D

17-01, 02,03 Wallpaper

1st Floor - North

Dorm Rooms, South Dorm Room

None Detected N/A F SD

18-01, 02,03

Blue Cove Base / Tan

Mastic

1st Floor - Central

Room, North

Hallway, North

Dorm Room

None Detected N/A NF D

TTL Project No. 26-09-00191.00 Page 6 of 15

TABLE 1: Asbestos Sample Results Summary

Building 7362

1359 Tinker Avenue, JBSA Lackland Air Force Base, San Antonio, Texas 78236

Sample

No.

Suspect Material Sample Location Asbestos %

Estimated

Quantities

Friability

(F/NF)

Condition

19-01, 02,03

Grey Cove Base / Tan

Mastic

1st Floor - North

Dorm Room None Detected N/A NF D

20–01, 02, 03 Tan Carpet Mastic

1st Floor - North

Hallway, North

Dorm Room, South

Hallway

None Detected N/A NF D

21-01, 02,03 Floor Tile / Mastic

1st Floor - North

Dorm Rooms None Detected N/A NF D

22-01, 02,03

4” Ceramic Wall Tile, Grout, & Thin set

1st Floor - North &

South Restrooms

MR: 2% Chrysotile

JC: 2% Chrysotile

1,000 SF NF D

23-01, 02,03

1” Ceramic Tile Grout

& Thin set

1st Floor - North &

South Restrooms TS: 2% Chrysotile 500 SF NF D

24-01, 02,03 HVAC Mastic

1st Floor -

Mechanical Room None Detected N/A NF D

25-01, 02,03

Pipe Insulation &

White Mastic

1st Floor -

Mechanical Room M: 2% Chrysotile 50 LF F D

26-01, 02,03 Grey Pipe Insulation

Basement - Boiler

Room None Detected N/A F D

27-01, 02,03

Boiler Wrap & White

Mastic

Basement - Boiler

Room M: 2% Chrysotile 50 SF F D

28-01, 02,03

9" x 9" Red / Maroon

VCT with White

Streaks / Black

Mastic

Basement - West

Room FT: 5% Chrysotile 500 SF NF G

29-01, 02,03

Texture & Grout associated with CMU Basement None Detected N/A NF D

30–01, 02, 03 Texture on Concrete Basement None Detected N/A NF D

31-01, 02,03

Smooth Texture

Drywall System

Basement - Boiler

Room

JC: 2% Chrysotile

TX: 2% Chrysotile

200 SF F SD

32-01, 02,03 EIFS Wall System Exterior None Detected N/A F D

33-01, 02,03 Sealant on Door Exterior None Detected N/A NF SD

34-01, 02,03 Wrap on HVAC Duct Exterior None Detected N/A F SD

LEGEND

SF – Square Feet MR - Mortar TS – Thin set

G – Good F – Friable FT – Floor Tile

D – Damaged NF – Non-Friable M - Mastic

SD – Significantly Damaged N/A – Not Applicable TX – Texture

PACM – Presumed Asbestos-Containing Materials * – Positive for Asbestos JC – Joint Compound

VCT – Vinyl Composition Tile

1.3 Findings

The laboratory analytical results identified asbestos at 1% or greater in the following materials:

▪ Joint compounds and textures associated with drywall ceiling and wall systems throughout the 2nd floor. The wallpaper and mortar associated with ceramic wall tiles

TTL Project No. 26-09-00191.00 Page 7 of 15 are also asbestos containing or considered cross-contaminated due to contact with asbestos-containing joint compound.

▪ Sink under coating found in 2nd floor central room.

▪ Joint compound and lace texture associated with drywall system within the stairwells

▪ Cementitious paneling found in 2nd floor storage room, 1st floor mechanical room and basement

▪ Joint compound and/or textures associated with the drywall ceiling and wall systems located throughout the 1st floor. The mortar set associated with ceramic wall tiles are also asbestos containing or considered cross-contaminated due to contact with asbestos-containing joint compound.

▪ Thin set associated with 1” ceramic floor tile found on 1st floor

▪ White mastic associated with pipe insulation found on 1st floor

▪ 9” x 9” red/maroon VCT with white streaks found in basement

▪ Joint compound and smooth texture associated with drywall system located in basement

Two parallel pipes were observed in the basement that with danger asbestos warning signs therefore are assumed to be ACM. The location of this pipe wrap was noted and included in the Site sample location map is provided in Appendix A.

The laboratory report and chain of custody are provided in Appendix B.

1.4 Asbestos Recommendations

ACMs identified at the building that will be impacted by renovation or demolition should be removed and disposed of in accordance with federal, state, and local regulation, prior to disturbance. It is recommended that the asbestos abatement must be performed by a TDSHS licensed asbestos abatement contractor in accordance with a project design prepared by a TDSHS licensed asbestos consultant. In addition, third party air monitoring should be performed during the abatement. Prior to initiating an asbestos abatement project, written notification must be provided no later than 10 calendar days prior to starting abatement.

Contractors should use caution during construction related activities as concealed suspect ACM or other hazardous materials that were not previously analyzed may be encountered. If additional material, not previously sampled are later identified during construction related activities, then supplemental sample should be performed.

Materials that were noted as none-detected for asbestos may be disposed of as general construction debris.

TTL Project No. 26-09-00191.00 Page 8 of 15

2.0 LEAD BASED PAINT SURVEY

As part of the Hazardous Materials Survey, TTL representative Mr. Nicolas Espino, a Texas Department of State Health Services (TDSHS) certified Lead Risk Assessor (license number 2071258) conducted a lead-based paint (LBP) survey at the Site on January 21, 2026.

2.1 Sampling Methods

The LBP sampling was conducted in general accordance with sampling guidelines and methodologies documented in the U.S. Department of Housing and Urban Development (HUD) Guidelines for the

Evaluation and Control of Lead-Based Paint Hazards in Housing, Second Edition dated July 2012 and

EPA Lead: Requirements for Lead-Based Paint Activities in Target Housing and Child-Occupied

Facilities, dated August 1996. Paint chip sampling methods were utilized to complete this survey.

Lead-based paint (LBP) is defined as paint containing >1.0 milligrams per square centimeter (mg/cm2) as measured by >0.5% of lead by weight as analyzed by Atomic Absorption, for the purposes of renovation and/or demolition work. Occupational Safety and Health Administration (OSHA) defines

LBP as any paint containing detectable amounts of lead.

The scope of work required a visual inspection and sampling of all painted surfaces from the Site.

Paint chip samples were collected from painted areas throughout the Site.

2.2 Paint Chip Sample Summary

A total of seventeen (17) paint chip samples were collected from painted areas at the Site. The samples were submitted to SanAir Technologies Laboratory, North Chesterfield, Virginia. The samples were analyzed for total lead utilizing EPA Method SW846/M3050B/7000B. A summary of the samples collected, and analytical results are presented in Table 2.

TTL Project No. 26-09-00191.00 Page 9 of 15

Table 2: Lead Based Paint Sample Results Building 7362

1359 Tinker Avenue, JBSA Lackland Air Force Base, San Antonio, Texas 78236

Sample ID Paint Color / Substrate Sample Location

Lead

Concentration % by Weight

Approximate

Quantity (SF)

L-01 White Paint on Drywall 2nd Floor - South Hallway <0.010 N/A

L-02 Gray Paint on Wood Door

Frame

2nd Floor - South Dorm

Room

0.090 N/A

L-03 White Paint on Wood Door

Frame

2nd Floor - North Dorm

Room

0.127 N/A

L-04 Cream on Wood Door 2nd Floor - Central Room 0.152 N/A

L-05 Cream Paint on Drywall North Stairwell <0.010 N/A

L-06 Gray Paint on Pressboard

Panel 2nd Floor - North Stairwell <0.010 N/A

L-07 White Paint on Drywall

Ceiling 1st Floor - South Restroom 0.050 N/A

L-08 Gray Paint on Metal Door

Hardware 1st Floor - North Stairwell 0.207 N/A

L-09 Brown Paint on Metal

Railing Exterior <0.010 N/A

L-10 Brown Paint on Concrete Exterior <0.008 N/A

L-11 Cream Paint on EIFS Exterior <0.010 N/A

L-12 White Paint on Concrete Basement 0.081 N/A

L-13 White Paint on CMU Basement 0.067 N/A

L-14 White Paint on Wood Door Basement 0.054 N/A

L-15 Black Paint on Metal Pipe Basement 0.109 N/A

L-16 Gray Paint on Metal Boiler Basement 0.209 N/A

L-17 Green Paint on Wood Door Basement 2.126 25 SF

Laboratory analysis indicated that one (1) of the seventeen (17) samples collected from the Site indicated a concentration of lead of 0.5% concentration by weight or greater, as noted below:

• Green paint on wood door (L-17)

A sample location map depicting all sampling locations is included in Appendix A. The laboratory results can be found in Appendix B.

TTL Project No. 26-09-00191.00 Page 10 of 15

2.4 Lead Recommendations

Contractor(s) should be made aware of the results for LBP. LBP that is in poor or deteriorated condition or that is disturbed during renovation by dry sanding, scraping, brushing, or burning can produce dust with lead, which can be inhaled or enter the body from hand-to-mouth contact.

Prior to performing renovation or demolition activities, the contractor should be made aware of the presence of LBP or potential LBP particularly in the areas of observed damaged paint to satisfy the hazard communication requirements set forth by OSHA regulations. Specifically, the contractors should be required to comply with OSHA regulations including 29 CFR 1926.62, Lead Exposure in

Construction: Interim Final Rule and 29 CFR 1926.59, Hazardous Communication for the Construction

Industry.

If any renovation, repair or demolition activity will disturb the LBP, engineering controls such as barriers and water should be used to minimize dust levels. The public should be prevented from unauthorized access to the work area. Ambient air monitoring is recommended to document engineering controls are adequate and that the ambient airborne concentrations do not exceed the permissible exposure levels.

TTL Project No. 26-09-00191.00 Page 11 of 15

3.0 LIMITED HAZARDOUS COMPONENTS SURVEY

As part of this Hazardous Materials Survey, a Limited Hazardous Components Survey was conducted at the Site on January 21, 2026.

3.1 Purpose and Scope

S purpose of the Hazardous Component Survey was to visually identify suspect hazardous components at the Site. This survey included identifying equipment that may contain Polychlorinated Biphenyls

(PCBs) or Mercury that may be handled during renovation. These components may be subject to special handling for recycling or waste disposal prior to demolition activities. A hazardous component location map can be found in Appendix A.

3.2 Polychlorinated Biphenyls

PCBs are a class of man-made organic chemicals manufactured and used from the late 1920s until

1979 when the EPA banned its manufacture. PCBs are stable, resistant to acids and bases, have thermal stability, and fire resistance properties. These special properties led to widespread use of

PCBs in industrial and commercial applications including electrical, heat transfer, hydraulic, and lighting equipment, caulks, paint, coatings, etc. The EPA regulates PCBs through several statutes, the most comprehensive of which is the Toxic Substances Control Act of 1976 codified in 40 CFR Part

761. This regulation governs the use, marking, storage, recording, and disposal of PCBs and PCB waste. In Texas, PCB waste is regulated by the Texas Commission on Environmental Quality (TCEQ) through 30 Texas Administrative Code (TAC) Chapter 335.

Fluorescent Lamp Ballasts

Fluorescent Lamp Ballasts (FLBs) manufactured prior to July 1, 1979 may contain PBCs. FLB manufactured between July 1. 1978 and July 1, 1998 that do not contain PCBs must be labeled “No

PCBs”. If an FLB is not labeled "No PCBs", it is best to assume it contains PCBs unless it is known to be manufactured after 1979. FLBs manufactured after 1998 are not required to be labeled.

To inspect a light fixture for the presence of PCBs, parts of the fixture were temporarily removed to expose the ballast (if present) and identify a “no PCBs” label. A photograph was taken for every newly encountered ballast before the fixture was reassembled. Details regarding the styles of fluorescent light fixtures identified are provided below.

Approximately 110 individual ceiling mounted FLBs were observed throughout the building.

Approximately 10% of these fixtures were disassembled and the “No PCBs” label was observed.

Electric Transformers

Dielectric fluids in electrical transformers may contain PCBs. A pole mounted transformer was observed near the exterior to the south of the building. The labels did not indicate the presence or absence of PCBs – additional investigation is required to determine the presence of PCBs in the dielectric fluids therein.

3.3 Mercury

Mercury is found in thermostats, switches, thermometers, compact fluorescent lamps (CFL) bulbs and fluorescent and high-intensity discharge lamps.

Approximately 110 of the ballasts at the Site were equipped with mercury containing fluorescent tube bulbs. Of the 110 ballasts observed, 56 of these lighting fixtures contained four (4) tube bulbs per ballast and 54 contained two (2) tube bulbs per ballast. A total of 19 CFLs were observed throughout the interior of the building. All mercury containing bulbs should be disposed of in accordance with applicable rules and regulations. All fluorescent bulbs must be disposed of as a Universal Waste at an EPA approved recycling facility prior to any renovation / demolition activities.

TTL Project No. 26-09-00191.00 Page 12 of 15

All thermostats observed throughout the building were electric and do not contain mercury. All thermostats must be disposed as a Universal Waste at an EPA approved recycling facility prior to any renovation / demolition activities.

3.4 Additional Hazardous Components

Approximately ten Illuminated exit signs were observed throughout the building. Approximately 10% of these fixtures were disassembled and they were found to contain Nickel-Cadmium rechargable back-up batteries. These batteries must be disposed of as Universal Waste at an EPA approved recycling facility prior to any renovation / demolition activities.

TTL Project No. 26-09-00191.00 Page 13 of 15

4.0 LIMITED MOLD ASSESSMENT

As part of the Hazardous Materials Survey, On January 21, 2026, TTL representative Mr. Nicolas

Espino, a Texas Department of Licensing and Regulation (TDLR) licensed Mold Assessment Consultant

(MAC) completed a limited mold assessment and sampling of the Site area, which included the following.

4.1 LIMITED MOLD ASSESSMENT METHODS

TTL conducted a limited mold assessment in accordance with TDLR Texas Mold Assessors and

Remediators Administrative Rules (TMARR) as well as applicable portions of the Institute of Inspection, Cleaning and Restoration Certifications (IICRC) Standard and Reference Guide for Professional Water

Damage Restoration, Fourth Addition and the American Society for Testing and Materials (ASTM)

D7338-14 Standard Guide for Assessment of Fungal Growth in Buildings. The assessment included the following:

4.1.1 Building Materials Moisture Assessment

The relative moisture content (MC) of building materials potentially affected by moisture/water intrusion were measured by a moisture meter and or an infrared (IR) camera to identify temperature differentials that may be associated with wet building materials.

4.1.2 Indoor Air Parameters

TTL collected measurements of indoor relative humidity and temperature concentrations, as well as outdoors for comparison purposes utilizing a hand-held direct read instrument.

4.1.3 Bioaerosol Samples

Samples were collected in accordance with the American Council of Government Industrial Hygienist

(ACGIH) protocol outlined in “Bioaerosols: Assessment and Control”. Samples were collected by drawing air across an adhesive material within a “spore trap” cassette. Ambient air is drawn over the spore trap using a high-volume vacuum pump, calibrated to draw 15 liters of air per minutes, for five minutes.

4.2 MOLD ASSESSMENT FINDINGS

4.2.1 Visual Observations and Building Materials Moisture Assessment

Areas of suspect water damage and visible mold growth were observed in the following areas:

• Central rooms on the first and second floors.

• In the dorm room closets on the first and second floors.

• On the door in the second-floor mechanical room.

• On the walls and ceiling in the second-floor hallway.

• On the ceiling of the second-floor restroom.

• On walls and ceiling of the first-floor stairwell.

• Paint on the western exterior wall was heavily chipped, likely from sub level water intrusion in the basement.

• The carpet in the west room of the basement had visible water staining.

Water damage and mold growth are likely from a water intrusion event from damaged or poor building seals and lack of functioning air conditioning.

TTL Project No. 26-09-00191.00 Page 14 of 15

4.2.2 Indoor Air Parameters

The American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standard

62.1-2016, Ventilation for Acceptable Indoor Mold recommends an indoor temperature of 680

Fahrenheit (F) to 740F in the winter and 720F to 800F in the summer, and an indoor relative humidity

(RH) level of <65% to reduce the likelihood of conditions that can lead to microbial growth. Table 3, found below, lists the conditions observed during the assessment.

Table 3: Indoor Air Parameters

Building 7362

1359 Tinker Avenue, JBSA Lackland Air Force Base, San Antonio, Texas 78236

Area / Location Temperature 0F Relative Humidity (RH) %

1st Floor – Central Room 61.8 F 72.9%

2nd Floor – Central Room 62.0 F 87.2%

Basement – Central Hallway 63.5 F 58.4%

Outdoor Control – Exterior 60.8 F 86.8%

The RH readings taken throughout the Site showed RH were significantly above normal range. The temperature throughout the building was within industry standards.

4.2.2 Bioaerosol Sample Results

Three (3) indoor spore trap samples were collected from the Site, and one (1) outdoor sample for comparison. Samples were submitted under chain of custody to Moody Labs (Moody) located in

Farmers Branch, Texas. Moody is a TDLR license Mold Lab (LAB0117) and accredited by the American

Industrial Hygiene Association (AIHA) (102577). Summary of sample results can be found on the table below:

TTL Project No. 26-09-00191.00 Page 15 of 15

Table 4: Air Spore Sample Results

Building 7362

1359 Tinker Avenue, JBSA Lackland Air Force Base, San Antonio, Texas 78236

Sample ID. OS-01 ST-01 ST-02 ST-03

Sample Location Outdoor Control 1st Floor – Central

Room

2nd Floor –

Central Room

Basement –

Central Hallway

Identification Spores/m3 Spores/m3 Spores/m3 Spores/m3

Alternaria 240 160 40

Ascospores 413 520 93 133

Aspergillus / Penicillium 27 67 40 253

Basidiospores 80 240 147 347

Cladosporium 387 2905 1905 866

Coprinus group 80

Curvularia 147 80 80

Dreschslera/Bipolaris

/Helminthosporum / Exserohilum group 200 107 67

Epicoccum 27 27

Fusarium 53

Hyphal / Spore Fragments - Dematiaceous 53 520 320 293

Myxomycete / Periconia / Rust / Smut 13 613 400 107

Pithomyces 80 40

Spores/m3 Total 973 5639 3372 2186

Laboratory results indicated higher levels of mold spores in the indoor samples of the building compared in the outdoor control sample.

The sample location maps are found in Appendix A. Laboratory analysis results can be found in

Appendix B.

4.3 MOLD ASSESSMENT CONCLUSIONS

• Areas of suspect water damage and visible mold growth were observed throughout the building.

• The indoor spore trap samples were elevated compared to the outdoor comparison sample.

• The relative humidity was significantly above the recommended levels and could be attributed to faulty seals on doors and windows of the building and elevated moisture from the HVAC system not currently operating.

Appendices

APPENDIX A

SAMPLE LOCATION MAPS

17215 Jones Maltsberger Road

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

A-1

01/26/2026

26-09-00191.00

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

AS

BE

ST

O

S

CO

N

TA

IN

IN

G M

AT

ER

IA

LS

SA

M

PL

E

LO

CA

TI

O

N S

LEGEND

NEGATIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

POSITIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

2-01 3-01

2-02

13-03

12-02

1-03

5-01 1-02

7-02 7-03

8-03 9-01,02,03 4-01 6-01

4-0213-01

14-01 7-01

8-01

3-02

8-02

6-02

4-03

6-03 3-03

1-01 2-03

10-01,02,03 11-01,02,03

5-025-03

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

LEGEND

NEGATIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

POSITIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

16-03 17-03

15-03

20-03

12-03

22-02 22-01

23-01

14-02

24-01,02,03

25-01,02,03

15-02

18-01

12-01

13-02

17-02 16-02

18-02

20-0223-02

23-03

22-03

18-03

15-01

16-01

17-01 19-03

19-01

19-02 21-01,02

20-01

21-03

32-02

32-03

32-01

33-01,02,03

A-2

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

AS

BE

ST

O

S

CO

N

TA

IN

IN

G M

AT

ER

IA

LS

SA

M

PL

E

LO

CA

TI

O

N S

34-01,02,03

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

LEGEND

NEGATIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

POSITIVE ASBESTOS CONTAINING

MATERIALS SAMPLE LOCATION

28-03

28-02

30-03

28-01

30-02 30-01

14-03

31-02

31-03

26-01,02,03

27-01,02,03

31-01

29-0129-02

29-03

A-3

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

AS

BE

ST

O

S

CO

N

TA

IN

IN

G M

AT

ER

IA

LS

SA

M

PL

E

LO

CA

TI

O

N S

PIPE WRAP LABELED AS ASBESTOS

CONTAINING MATERIALS

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

LE

AD

B

AS

ED

P

AI

N

T

SU

RV

EY

SA

M

PL

E

LO

CA

TI

O

N S

LEGEND

<10 ug REPORTING LIMIT

FOR LEAD PAINT CHIP

SAMPLE LOCATION

<0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

>0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

L-05

L-06

L-04

L-01

L-02 L-03

A-4

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

26-09-00191.00

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

LEGEND

<10 ug REPORTING LIMIT

FOR LEAD PAINT CHIP

SAMPLE LOCATION

<0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

>0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

L-07

L-09 L-08

L-10

L-11

LE

AD

B

AS

ED

P

AI

N

T

SU

RV

EY

SA

M

PL

E

LO

CA

TI

O

N S

A-5

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

LEGEND

<10 ug REPORTING LIMIT

FOR LEAD PAINT CHIP

SAMPLE LOCATION

<0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

>0.5% CONCENTRATION

BY WEIGHT LBP SAMPLE

LOCATION

L-17

L-13

L-14

L-16

L-12 L-15

LE

AD

B

AS

ED

P

AI

N

T

SU

RV

EY

SA

M

PL

E

LO

CA

TI

O

N S

A-6

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

HA

ZA

RD

O

U S

CO

M

PO

N

EN

TS

S U

RV

EY

A-7

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

LEGEND

MERCURY CONTAINING CFL BULBSM

NON-PCB LIGHTING BALLAST WITH TWO (2)

MERCURY CONTAINING BULBS

ILLUMINATED EXIT SIGN WITH LEAD ACID

BATTERYEXIT

EXIT EXIT EXIT EXIT

NON-PCB LIGHTING BALLAST WITH FOUR (4)

MERCURY CONTAINING BULBS4

4 4 4 4 4 4 4 4

4 4 4 4 4 4

4 4 4 4 4 4 4 4

4 4 4 4 4 4

M

M M

M M

M

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

HA

ZA

RD

O

U S

CO

M

PO

N

EN

TS

S U

RV

EY

A-8

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

LEGEND

MERCURY CONTAINING CFL BULBSM

NON-PCB LIGHTING BALLAST WITH TWO (2)

MERCURY CONTAINING BULBS

ILLUMINATED EXIT SIGN WITH LEAD ACID

BATTERYEXIT

NON-PCB LIGHTING BALLAST WITH FOUR (4)

MERCURY CONTAINING BULBS4

ET

EXIT EXIT EXIT EXIT

4 4 4 4

4 4 4

4 4 4 4 4 4 4 4

4 4 4 4 4 4

M

M M

M M

M

M

4 4

4 4 4 4

ET

ELECTRONIC THERMOSTAT

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

HA

ZA

RD

O

U S

CO

M

PO

N

EN

TS

S U

RV

EY

A-9

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

LEGEND

MERCURY CONTAINING CFL BULBSM

NON-PCB LIGHTING BALLAST WITH TWO (2)

MERCURY CONTAINING BULBS

ILLUMINATED EXIT SIGN WITH LEAD ACID

BATTERYEXIT

EXITEXIT

M

M

M M

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Drawn By:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

25-09-01680.00

M O

LD

A

SS

ES

SM

EN

T

SA

M

PL

E

LO

CA

TI

O N

M

AP

Date:

Scale:

06/24/2025

ST-02

SPORE TRAP SAMPLE LOCATION

LEGEND

WATER DAMAGE LOCATIONS

VISIBLE MOLD GROWTH ON CEILING

VISIBLE MOLD GROWTH ON WALLS

A-10

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

Date:

Scale:

17215 Jones Maltsberger Road San Antonio, TX 78247

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Drawn By:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

25-09-01680.00

06/24/2025

25-09-01680.00

ST-01

SPORE TRAP SAMPLE LOCATION

LEGEND

WATER DAMAGE LOCATIONS

VISIBLE MOLD GROWTH ON CEILING

VISIBLE MOLD GROWTH ON WALLS

M O

LD

A

SS

ES

SM

EN

T

SA

M

PL

E

LO

CA

TI

O N

M

AP

A-11

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622

Checked By:

Date:

Drawn By:

Scale:

Proj. No.:

File Name:

NOT TO SCALE

DS

NE

EXHIBIT

01/26/2026

26-09-00191.00

SPORE TRAP SAMPLE LOCATION

LEGEND

WATER DAMAGE LOCATIONS

VISIBLE WATER DAMAGE ON WALLS

ST-03

M O

LD

A

SS

ES

SM

EN

T

SA

M

PL

E

LO

CA

TI

O N

M

AP

A-12

JBSA-LAK-7362.dwg

BU

IL

DI

N

G

JB

SA

LA

CK

LA

N D

AI

R

FO

RC

E

BA

SE

SA

N A

N

TO

N

IO

, T

EX

AS

Appendices

APPENDIX B

LABORATORY RESULTS

PLM Summary Report

Client :

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

1-01 Drywall Ceiling Texture (Popcorn), 2nd Floor, North Dorm

Room, South Dorm Room

None Detected - Drywall Material

None Detected - Joint Compound

None Detected - Texture

1-02 Drywall Ceiling Texture (Popcorn), 2nd Floor, North Dorm

Room, South Dorm Room

None Detected - Drywall Material

None Detected - Joint Compound

None Detected - Acoustic Texture

1-03 Drywall Ceiling Texture (Popcorn), 2nd Floor, North Dorm

Room, South Dorm Room

None Detected - Drywall Material

2% Chrysotile - Joint Compound

2% Chrysotile - Acoustic Texture

2-01 Drywall Texture (Perlite), 2nd Floor, South Dorm Rooms, North Dorm Room

2% Chrysotile - Joint Compound

2% Chrysotile - Old Texture

2% Chrysotile - New Texture

2-02 Drywall Texture (Perlite), 2nd Floor, South Dorm Rooms, North Dorm Room

Not Analyzed - Positive Stop

2-03 Drywall Texture (Perlite), 2nd Floor, South Dorm Rooms, North Dorm Room

Not Analyzed - Positive Stop

3-01 Drywall with Wallpaper, 2nd Floor, South Dorm Room, North Restroom, North Dorm Room

No Drywall Material

None Detected - Joint Compound

None Detected - Wallpaper

3-02 Drywall with Wallpaper, 2nd Floor, South Dorm Room, North Restroom, North Dorm Room

No Drywall Material

2% Chrysotile - Joint Compound

None Detected - Wallpaper

3-03 Drywall with Wallpaper, 2nd Floor, South Dorm Room, North Restroom, North Dorm Room

Not Analyzed - Positive Stop

4-01 Mastic (Tan) associated with Cove Base (Blue), 2nd Floor, Central Room, North Stairwell, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

4-02 Mastic (Tan) associated with Cove Base (Blue), 2nd Floor, Central Room, North Stairwell, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

4-03 Mastic (Tan) associated with Cove Base (Blue), 2nd Floor, Central Room, North Stairwell, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

5-01 Mastic (Tan) associated with Cove Base (Grey), 2nd Floor, South Hallway

None Detected - Cove Base

None Detected - Tan Mastic

5-02 Mastic (Tan) associated with Cove Base (Grey), 2nd Floor, South Hallway

None Detected - Cove Base

None Detected - Tan Mastic

5-03 Mastic (Tan) associated with Cove Base (Grey), 2nd Floor, South Hallway

None Detected - Cove Base

None Detected - Tan Mastic

6-01 Carpet Mastic (Tan), 2nd Floor, Central Room, North

Hallway, North Dorm Room

None Detected - Tan Mastic

6-02 Carpet Mastic (Tan), 2nd Floor, Central Room, North

Hallway, North Dorm Room

None Detected - Tan Mastic

6-03 Carpet Mastic (Tan), 2nd Floor, Central Room, North

Hallway, North Dorm Room

None Detected - Tan Mastic

7-01 4" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

None Detected - Ceramic Tile

None Detected - Grout

2% Chrysotile - Mortar

None Detected - Thinset

7-02 4" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

Not Analyzed - Positive Stop

7-03 4" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

Not Analyzed - Positive Stop

8-01 1" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Thinset

8-02 1" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Thinset

8-03 1" Ceramic Tile Grout and Thinset, 2nd Floor, North and

South Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Thinset

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

9-01 HVAC Mastic, 2nd Floor, Mechanical Room None Detected - Clear Mastic

None Detected - Cotton Wrap

None Detected - Foil Wrap

None Detected - White Mastic

9-02 HVAC Mastic, 2nd Floor, Mechanical Room None Detected - Insulation

None Detected - Glass Fiber Wrap

None Detected - Clear Mastic

None Detected - Cotton Wrap

None Detected - Foil Wrap

None Detected - White Mastic

9-03 HVAC Mastic, 2nd Floor, Mechanical Room None Detected - Clear Mastic

None Detected - Cotton Wrap

None Detected - Foil Wrap

None Detected - White Mastic

10-01 Pipe Insulation, 2nd Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

10-02 Pipe Insulation, 2nd Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

10-03 Pipe Insulation, 2nd Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

11-01 Under Sink Coating, 2nd Floor, Central Room Sink 2% Chrysotile - Sink Undercoating

11-02 Under Sink Coating, 2nd Floor, Central Room Sink Not Analyzed - Positive Stop

11-03 Under Sink Coating, 2nd Floor, Central Room Sink Not Analyzed - Positive Stop

12-01 Vinyl on Stairs, North and South Stairwells None Detected - Stair Tread

12-02 Vinyl on Stairs, North and South Stairwells None Detected - Stair Tread

12-03 Vinyl on Stairs, North and South Stairwells None Detected - Stair Tread

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

13-01 Drywall with Texture (Lace), North and South Stairwells None Detected - Drywall Material

2% Chrysotile - Joint Compound

2% Chrysotile - Texture

13-02 Drywall with Texture (Lace), North and South Stairwells Not Analyzed - Positive Stop

13-03 Drywall with Texture (Lace), North and South Stairwells Not Analyzed - Positive Stop

14-01 Cementitious Paneling, 2nd Floor, Storage Room, 1st Floor

Mechanical Room

15% Chrysotile - Cement Asbestos

Board

14-02 Cementitious Paneling, 2nd Floor, Storage Room, 1st Floor

Mechanical Room

Not Analyzed - Positive Stop

14-03 Cementitious Paneling, 2nd Floor, Storage Room, 1st Floor

Mechanical Room

Not Analyzed - Positive Stop

15-01 Drywall Ceiling Texture (Popcorn), 1st Floor, North

Hallway, Central Room, South Hallway

None Detected - Drywall Material

2% Chrysotile - Joint Compound

None Detected - Acoustic Texture

15-02 Drywall Ceiling Texture (Popcorn), 1st Floor, North

Hallway, Central Room, South Hallway

Not Analyzed - Positive Stop

15-03 Drywall Ceiling Texture (Popcorn), 1st Floor, North

Hallway, Central Room, South Hallway

Not Analyzed - Positive Stop

16-01 Drywall Texture (Perlite), 1st Floor, North Dorm Rooms, South Dorm Room

None Detected - Drywall Material

2% Chrysotile - Old Texture

None Detected - New Texture

16-02 Drywall Texture (Perlite), 1st Floor, North Dorm Rooms, South Dorm Room

Not Analyzed - Positive Stop

16-03 Drywall Texture (Perlite), 1st Floor, North Dorm Rooms, South Dorm Room

Not Analyzed - Positive Stop

17-01 Drywall with Wallpaper, 1st Floor, North Dorm Rooms, South Dorm Room

No Drywall Material

None Detected - Wall Covering

17-02 Drywall with Wallpaper, 1st Floor, North Dorm Rooms, South Dorm Room

No Drywall Material

None Detected - Wall Covering

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

17-03 Drywall with Wallpaper, 1st Floor, North Dorm Rooms, South Dorm Room

No Drywall Material

None Detected - Wall Covering

18-01 Mastic (Tan) associated with Cove Base (Blue), 1st Floor, Central Room, North Hallway, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

18-02 Mastic (Tan) associated with Cove Base (Blue), 1st Floor, Central Room, North Hallway, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

18-03 Mastic (Tan) associated with Cove Base (Blue), 1st Floor, Central Room, North Hallway, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

19-01 Mastic (Tan) associated with Cove Base (Grey), 1st Floor, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

19-02 Mastic (Tan) associated with Cove Base (Grey), 1st Floor, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

19-03 Mastic (Tan) associated with Cove Base (Grey), 1st Floor, North Dorm Room

None Detected - Cove Base

None Detected - Tan Mastic

20-01 Carpet Mastic (Tan), 1st Floor, North Hallway, North Dorm

Room, South Hallway

None Detected - Tan Mastic

20-02 Carpet Mastic (Tan), 1st Floor, North Hallway, North Dorm

Room, South Hallway

None Detected - Tan Mastic

20-03 Carpet Mastic (Tan), 1st Floor, North Hallway, North Dorm

Room, South Hallway

None Detected - Tan Mastic

21-01 Floor Tile, 1st Floor, North Dorm Rooms None Detected - Floor Tile

None Detected - Tan Mastic

21-02 Floor Tile, 1st Floor, North Dorm Rooms None Detected - Floor Tile

None Detected - Tan Mastic

21-03 Floor Tile, 1st Floor, North Dorm Rooms None Detected - Floor Tile

None Detected - Tan Mastic

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

22-01 4" Ceramic Tile, Grout and Thinset, 1st Floor, North and

South Restrooms

None Detected - Ceramic Tile

None Detected - Grout

2% Chrysotile - Mortar

2% Chrysotile - Joint Compound

22-02 4" Ceramic Tile, Grout and Thinset, 1st Floor, North and

South Restrooms

Not Analyzed - Positive Stop

22-03 4" Ceramic Tile, Grout and Thinset, 1st Floor, North and

South Restrooms

Not Analyzed - Positive Stop

23-01 1" Ceramic Tile Grout and Thinset, 1st Floor, North and

South Restrooms

None Detected - Ceramic Tile

2% Chrysotile - Thinset

23-02 1" Ceramic Tile Grout and Thinset, 1st Floor, North and

South Restrooms

Not Analyzed - Positive Stop

23-03 1" Ceramic Tile Grout and Thinset, 1st Floor, North and

South Restrooms

Not Analyzed - Positive Stop

24-01 HVAC Mastic, 1st Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Cotton Wrap

None Detected - White Mastic

24-02 HVAC Mastic, 1st Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Cotton Wrap

None Detected - White Mastic

24-03 HVAC Mastic, 1st Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Cotton Wrap

None Detected - White Mastic

25-01 Pipe Insulation, 1st Floor, Mechanical Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

2% Chrysotile - White Mastic

25-02 Pipe Insulation, 1st Floor, Mechanical Room Not Analyzed - Positive Stop

Project :

Project # :

Identification :

Test Method :

TTL - San Antonio

Building 7362, JBSA Lackland AFB

26-09-00191.00

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/30/2026, one hundred two (102) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

26B-00997

01/21/2026

02/09/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

25-03 Pipe Insulation, 1st Floor, Mechanical Room Not Analyzed - Positive Stop

26-01 Pipe Insulation (Grey), Basement, Boiler Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

26-02 Pipe Insulation (Grey), Basement, Boiler Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

26-03 Pipe Insulation (Grey), Basement, Boiler Room None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

27-01 Boiler Wrap, Basement, Boiler Room None Detected -…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .