This is a Limited Hazardous Materials Survey Report for Building 2988 located at JBSA – Lackland Air Force Base in San Antonio, Texas, prepared by TTL, Inc. for the 802 CES/CENME, Execution Support organization.
The survey conducted on January 22, 2026, included three components: an asbestos-containing materials (ACM) survey, a lead-based paint (LBP) inspection, and a hazardous components survey. No mold assessment was performed due to the building's open exterior and metal/wood construction. Laboratory analysis identified 5% chrysotile asbestos in black mastic on the exposed metal roof decking of the East Shed (50 square feet, non-friable, good condition). For lead-based paint, one of three samples tested positive: yellow paint on metal framing in the West Shed contained 18.460% lead by weight (750 square feet), exceeding the 0.5% threshold for lead-based paint. Two other paint samples (red on wood trim and yellow on wood framing in the East Shed) tested below detection limits. The hazardous components survey noted that pole-mounted transformers west of Building 2988 require additional investigation to determine PCB presence; no fluorescent lamp ballasts or mercury-containing lighting ballasts were observed in the building. The report recommends that any ACM impacted by renovation or demolition be removed by a TDSHS-licensed contractor with project design by a licensed asbestos consultant and third-party air monitoring. Contractors must comply with OSHA lead exposure regulations (29 CFR 1926.62 and 1926.59) when disturbing lead-based paint, utilizing engineering controls and ambient air monitoring.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B7362 HazMat Report.pdf | ||
| PWS CTO MultiFacDemo JBSA_LAK_19May_FINAL.docx | DOCX document | |
| jbsanantonio7_UAR_20240920.pdf | ||
| B140 HazMat Report.pdf | ||
| B7561 HazMatRprt.pdf | ||
| Outage Request.pdf | ||
| B4395 HazMatRprt.pdf | ||
| B5584 HazMat Report.pdf | ||
| Solicitation Amendment - FA301626R00330001.pdf | ||
| Solicitation - FA301626R0033.pdf | ||
| B2989 HazMatRprt.pdf | ||
| WD-2015-5253 Rev 29.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Limited Hazardous Materials Survey
Building 2988 Located near Foster Avenue, 29º23’59.1”N, 98º36’49.3”W
JBSA – Lackland Air Force Base, Texas 78236
Prepared for:
802 CES/CENME, Execution Support
2250 Engineer Street - Building 4196
JBSA - Fort Sam Houston, Texas 78234
Prepared by:
TTL, Inc.
17215 Jones Maltsberger Road, Suite 101
San Antonio, Texas 78247
Project No. 29-09-00191.00
February 23, 2026
17215 Jones Maltsberger Rd., Ste. 101
San Antonio, TX 78247
210.888.6100 www. TTLUSA.com
Asbestos Consultant Agency No. 100550 ▪ Lead Firm No. 2110644 ▪ Mold Assessment Company No. ACO1228
February 23, 2026
Mr. Eraldo David Martinez
802 CES/CENME, Execution Support (JBSA - 802 CES/CENME, EXECUTION SUPPORT)
2250 Engineer Street, Building 4196
JBSA - Fort Sam Houston, Texas 78234
P: 210.295.4727
E: eraldo.martinez@us.af.mil
RE: Limited Hazardous Materials Survey Report
Building 2988
Near Foster Avenue (29º23’59.1”N, 98º36’49.3”W)
JBSA – Lackland Air Force Base, Texas 78236
TTL Project No. 26-09-00191.00
Dear Mr. Martinez, TTL, Inc. (TTL) is pleased to submit this Hazardous Materials Survey report for Building 2988 located near Foster Avenue (29º23’59.1”N, 98º36’49.3”W), JBSA – Lackland Air Force Base, Texas 78236, herein referred to as the “Site”. It should be noted that that JBSA – Lackland Air Force Base is considered a National Standards for Hazardous Air Pollutants (NESHAP) facility due to limited access to buildings and badging requirements.
Scope of Services
TTL was retained to conduct an asbestos-containing materials (ACM) survey, a lead-based paint (LBP) inspection, and a hazardous components survey. A mold assessment was not deemed necessary because the building was open to the exterior and made primarily of metal and wood.
The purpose of this survey was to determine the presence, quantity, and condition of suspect ACM, LBP, and hazardous components located at the Site. The field work for the hazardous materials survey was conducted on January 22, 2026.
Report
Laboratory results, sample location maps, and photographs are included in the appendices following the report. This report is divided into three (3) sections, which include an ACM Survey, LPB Survey, and a Hazardous Components Survey. A photo log is provided in Appendix C. Applicable licenses or certifications are provided in Appendix D.
Limitations
Observations and sampling performed during this site assessment are likely to be reasonable assessment of the conditions in the areas assessed at the Site. Environmental measurements within a building can vary from day to day and represent a snapshot on the day and time of the assessment.
This assessment did not include destructive sampling to check behind wallpaper, wall cavities or concealed areas for hazardous materials.
This report is intended for the sole use and benefit of JBSA - 802 CES/CENME, Execution Support and may not be relied upon by any other party without express permission of TTL.
http://www/
JBSA Lackland Air Force Base – Building 2988 – Hazardous Materials Survey February 23, 2026
TTL Project No. 26-09-00191.00 Page 2 of 24
© 2026, TTL, Inc. Passion | Purpose | Principles
TTL has no knowledge of any hidden or unapparent or adverse environmental conditions of the property, including the presence of hidden mold, hazardous wastes, toxic substances, etc. TTL makes no guarantees or warranties, express or implied, regarding the condition of the property. This report is not an environmental assessment of the property.
This report and associated conclusions are based on the visible conditions of the inspected areas and materials. TTL reserves the right to revise opinions and conclusions if necessary and warranted by the discovery of new or additional circumstances. This report is specific and limited in nature and shall not be relied on as a statement that all Hazardous Materials have been identified and that more exist beyond the visibly accessible areas.
Closing
TTL appreciates the opportunity to provide environmental consulting services to JBSA - 802
CES/CENME, EXECUTION SUPPORT on this phase of the project. Should you have any questions, or require additional information regarding the Hazardous Materials Survey, please call us at your convenience.
Respectfully submitted, Nicolas Espino Osanna Carrasco
Project Professional Sr. Project Manager
TDSHS Lead Risk Assessor 2071258 TDSHS Lead Project Designer 2090091
TDLR Mold Assessment Consultant MAC1943 TDLR Mold Assessment Consultant MAC1587
TTL Project No. 26-09-00191.00 Page 3 of 8
TABLE OF CONTENTS
1.0 ASBESTOS-CONTAINING MATERIAL SURVEY
1.1 Sampling Methods
1.2 Laboratory Analysis
1.3 Findings
1.4 Asbestos Recommendations
2.0 LEAD BASED PAINT SURVEY
2.1 Sampling Methods
2.2 Paint Chip Sample Summary
2.4 Lead Recommendations
3.0 LIMITED HAZARDOUS COMPONENTS SURVEY
3.1 Purpose and Scope
3.2 Polychlorinated Biphenyls
3.3 Mercury
APPENDIX A: SAMPLE LOCATION MAPS
APPENDIX B: LABORATORY RESULTS
APPENDIX C: SITE PHOTOGRAPHS
APPENDIX D: LICENSES AND CERTIFICATIONS
TTL Project No. 26-09-00191.00 Page 4 of 8
1.0 ASBESTOS-CONTAINING MATERIAL SURVEY
The limited asbestos survey was conducted on January 22, 2026, by TDSHS-licensed Asbestos inspectors Deborah Salahuddin (license number 603987), and Nicolas Espino (license number
603646).
1.1 Sampling Methods
TTL performed the limited asbestos inspection survey in general accordance with Texas Department of State Health Services (TDSHS) Administrative Code Title 25, Part 1, Chapter 296, Texas Asbestos
Health Protection Rules (TAHPR), as well as the United States Environmental Protection Agency
(USEPA) National Standards for Hazardous Air Pollutants (NESHAP). Approximate quantities of suspect materials were estimated by field measurements. The condition (e.g., good, damaged, significantly damaged) and friability (i.e., easily crumbled, pulverized, or reduced to powder by hand pressure) of suspect ACM was noted for each material. The friability of each sampled material was determined by hand-touch.
• Surfacing materials, including spray-applied or troweled on wall/ceiling coatings,
• Thermal system insulation (TSI), including pipe insulation, duct insulation, boiler lagging and
• Miscellaneous materials, including ceiling panels/tiles, floor tiles and mastic, gaskets (if accessible), and wallboard/joint compound.
Suspected ACMs were grouped into homogeneous areas (i.e., a material that is uniform in texture, color, date of application, use or system, and appears identical in every other aspect). Homogeneous areas were determined by the TDSHS licensed Asbestos Inspector(s) based upon date of installation and uniformity or color and texture. Fiberglass, foam glass, rubber or wood products, plastic products, glass and steel were not sampled since they are not considered suspect ACM.
1.2 Laboratory Analysis
A total of three (3) bulk samples were collected from the selected areas of the interior of the building.
Samples were deposited in secure containers for transport to the analytical laboratory.
Bulk suspect asbestos samples were submitted under secure chain of custody and were analyzed utilizing Polarized Light Microscopy (PLM), following the USEPA PLM Method EPA-600/R-93/116. The bulk samples were analyzed by Moody Labs (Moody), in Farmers Branch, Texas. Moody is accredited by the National Institute of Standards and Technology National Voluntary Laboratory Accreditation
Program (NVLAP No. 102056-0) and licensed by TDSHS (license number 300084).
A summary of TTL’s asbestos sampling, including analytical results, sample number, material descriptions, sample locations, material condition, friability and estimated quantities is provided in
Table 1 below.
TTL Project No. 26-09-00191.00 Page 5 of 8
TABLE 1: Asbestos Sample Results Summary
Building 2988
Foster Avenue
JBSA Lackland Air Force Base, Texas 78236
Sample
No.
Suspect Material Sample Location Asbestos %
Estimated
Quantities
Friability
(F/NF)
Condition
1-01, 02,03
Black Mastic on
Metal Roof Deck East Shed 5% Chrysotile 50 SF NF G
LEGEND
SF – Square Feet
G – Good F – Friable FT – Floor Tile
D – Damaged NF – Non-Friable M - Mastic
SD – Significantly Damaged N/A – Not Applicable TX – Texture
PACM – Presumed Asbestos-Containing Materials * – Positive for Asbestos JC – Joint Compound
VCT – Vinyl Composition Tile
1.3 Findings
The laboratory analytical results identified asbestos at 1% or greater in the following materials:
▪ Black mastic found on exposed metal roof decking of the East Shed
Site sample location map is provided in Appendix A. The laboratory report and chain of custody are provided in Appendix B.
1.4 Asbestos Recommendations
ACMs identified at the building that will be impacted by renovation or demolition should be removed and disposed of in accordance with federal, state, and local regulation, prior to disturbance. It is recommended that the asbestos abatement must be performed by a TDSHS licensed asbestos abatement contractor in accordance with a project design prepared by a TDSHS licensed asbestos consultant. In addition, third party air monitoring should be performed during the abatement. Prior to initiating an asbestos abatement project, written notification must be provided no later than 10 calendar days prior to starting abatement.
Contractors should use caution during construction related activities as concealed suspect ACM or other hazardous materials that were not previously analyzed may be encountered. If additional material, not previously sampled are later identified during construction related activities, then supplemental sample should be performed.
Materials that were noted as none-detected for asbestos may be disposed of as general construction debris.
TTL Project No. 26-09-00191.00 Page 6 of 8
2.0 LEAD BASED PAINT SURVEY
As part of the Hazardous Materials Survey, TTL representative Mr. Nicolas Espino, a Texas Department of State Health Services (TDSHS) certified Lead Risk Assessor (license number 2071258) conducted a lead-based paint (LBP) survey at the Site on January 22, 2026.
2.1 Sampling Methods
The LBP sampling was conducted in general accordance with sampling guidelines and methodologies documented in the U.S. Department of Housing and Urban Development (HUD) Guidelines for the
Evaluation and Control of Lead-Based Paint Hazards in Housing, Second Edition dated July 2012 and
EPA Lead: Requirements for Lead-Based Paint Activities in Target Housing and Child-Occupied
Facilities, dated August 1996. Paint chip sampling methods were utilized to complete this survey.
Lead-based paint (LBP) is defined as paint containing >1.0 milligrams per square centimeter (mg/cm2) as measured by >0.5% of lead by weight as analyzed by Atomic Absorption, for the purposes of renovation and/or demolition work. Occupational Safety and Health Administration (OSHA) defines
LBP as any paint containing detectable amounts of lead.
The scope of work required a visual inspection and sampling of all painted surfaces from the Site.
Paint chip samples were collected from painted areas throughout the Site.
2.2 Paint Chip Sample Summary
A total of three (3) paint chip samples were collected from painted areas at the Site. The samples were submitted to SanAir Technologies Laboratory, North Chesterfield, Virginia. The samples were analyzed for total lead utilizing EPA Method SW846/M3050B/7000B. A summary of the samples collected, and analytical results are presented in Table 2.
Table 2: Lead Based Paint Sample Results Building 2988
Foster Avenue
JBSA Lackland Air Force Base, Texas 78236
Sample ID Paint Color / Substrate Sample Location
Lead
Concentration % by Weight
Approximate
Quantity (SF)
L-01 Yellow on Metal Framing West Shed 18.460 750 SF
L-02 Red on Wood Trim East Shed <0.009 N/A
L-03 Yellow on Wood Framing East Shed <0.009 N/A
Laboratory analysis indicated that one (1) of the three (3) samples collected from the Site indicated a concentration of lead of 0.5% concentration by weight or greater, as noted below:
• Yellow Paint on Metal Framing (L-01)
A sample location map depicting all sampling locations is included in Appendix A. The laboratory results can be found in Appendix B.
2.4 Lead Recommendations
Contractor(s) should be made aware of the results for LBP. LBP that is in poor or deteriorated condition or that is disturbed during renovation by dry sanding, scraping, brushing, or burning can produce dust with lead, which can be inhaled or enter the body from hand-to-mouth contact.
Prior to performing renovation or demolition activities, the contractor should be made aware of the presence of LBP or potential LBP particularly in the areas of observed damaged paint to satisfy the hazard communication requirements set forth by OSHA regulations. Specifically, the contractors should be required to comply with OSHA regulations including 29 CFR 1926.62, Lead Exposure in
TTL Project No. 26-09-00191.00 Page 7 of 8
Construction: Interim Final Rule and 29 CFR 1926.59, Hazardous Communication for the Construction
Industry.
If any renovation, repair or demolition activity will disturb the LBP, engineering controls such as barriers and water should be used to minimize dust levels. The public should be prevented from unauthorized access to the work area. Ambient air monitoring is recommended to document engineering controls are adequate and that the ambient airborne concentrations do not exceed the permissible exposure levels.
TTL Project No. 26-09-00191.00 Page 8 of 8
3.0 LIMITED HAZARDOUS COMPONENTS SURVEY
As part of this Hazardous Materials Survey, a Limited Hazardous Components Survey was conducted at the Site on January 22, 2026.
3.1 Purpose and Scope
The purpose of the Hazardous Component Survey was to visually identify suspect hazardous components at the Site. This survey included identifying equipment that may contain Polychlorinated
Biphenyls (PCBs) or Mercury that may be handled during renovation. These components may be subject to special handling for recycling or waste disposal prior to demolition activities.
3.2 Polychlorinated Biphenyls
PCBs are a class of man-made organic chemicals manufactured and used from the late 1920s until
1979 when the EPA banned its manufacture. PCBs are stable, resistant to acids and bases, have thermal stability, and fire resistance properties. These special properties led to widespread use of
PCBs in industrial and commercial applications including electrical, heat transfer, hydraulic, and lighting equipment, caulks, paint, coatings, etc. The EPA regulates PCBs through several statutes, the most comprehensive of which is the Toxic Substances Control Act of 1976 codified in 40 CFR Part
761. This regulation governs the use, marking, storage, recording, and disposal of PCBs and PCB wastes. In Texas, PCB waste is regulated by the Texas Commission on Environmental Quality (TCEQ) through 30 Texas Administrative Code (TAC) Chapter 335.
Fluorescent Lamp Ballasts
Fluorescent Lamp Ballasts (FLBs) manufactured prior to July 1, 1979 may contain PBCs. FLB manufactured between July 1. 1978 and July 1, 1998 that do not contain PCBs must be labeled “No
PCBs”. If an FLB is not labeled "No PCBs", it is best to assume it contains PCBs unless it is known to be manufactured after 1979. FLBs manufactured after 1998 are not required to be labeled.
FLBs were not observed in Building 2988.
Electric Transformers
Dielectric fluids in electrical transformers may contain PCBs. Pole mounted transformers were observed off-site to the west of Building 2988. The labels did not indicate the presence or absence of
PCBs – additional investigation is required to determine the presence of PCBs in the dielectric fluids therein.
3.3 Mercury
Mercury is found in thermostats, switches, thermometers, compact fluorescent bulbs and fluorescent and high-intensity discharge lamps.
Lighting ballasts and thermostats were not observed in Building 2988.
Appendices
APPENDIX A
SAMPLE LOCATION MAPS
WEST SHED EAST SHED
17215 Jones Maltsberger Road San Antonio, TX 78247
210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622
Checked By:
Date:
Drawn By:
Scale:
Proj. No.:
File Name:
NOT TO SCALE
DS
NE
EXHIBIT
A-1
01/26/2026
26-09-00191.00
AS
BE
ST
O
S
CO
N
TA
IN
IN
G M
AT
ER
IA
LS
SA
M
PL
E
LO
CA
TI
O
N S
LEGEND
POSITIVE ASBESTOS CONTAINING
MATERIALS SAMPLE LOCATION
1-01
1-02
1-03
JBSA-LAK-B2988.dwg
B U
IL
DI
N G
JB
SA
LA
CK
LA
N
D
AI
R
FO
RC
E
BA
SE
SA
N
A N
TO
N
IO
, T
EX
AS
West Shed
West Shed
WEST SHED EAST SHED
17215 Jones Maltsberger Road San Antonio, TX 78247
210.888.6100 | www.ttlusa.com TBPE Firm Registration F-12622
Checked By:
Date:
Drawn By:
Scale:
Proj. No.:
File Name:
NOT TO SCALE
DS
NE
EXHIBIT
A-2
01/26/2026
26-09-00191.00
JBSA-LAK-B2988.dwg
B U
IL
DI
N G
JB
SA
LA
CK
LA
N
D
AI
R
FO
RC
E
BA
SE
SA
N
A N
TO
N
IO
, T
EX
AS
LE
AD
B
AS
ED
P
AI
N
T
SU
RV
EY
SA
M
PL
E
LO
CA
TI
O
N S
LEGEND
<10 ug REPORTING LIMIT
FOR LEAD PAINT CHIP
SAMPLE LOCATION
>0.5% CONCENTRATION
BY WEIGHT LBP SAMPLE
LOCATION
L-01
L-02
L-03
APPENDIX B
LABORATORY RESULTS
PLM Summary Report
Client :
Project :
Project # :
Identification :
Test Method :
TTL - San Antonio
Building 2988, JBSA, Lackland AFB, 802 CES/CENME
26-09-00191.00
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 1/30/2026, three (3) bulk material samples were submitted by a representative of TTL - San Antonio for asbestos analysis by PLM/DS. The PLM
Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
26B-01028
01/22/2026
02/06/2026
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
1-01 Mastic (Black), East Shed 5% Chrysotile - Black Mastic
1-02 Mastic (Black), East Shed Not Analyzed - Positive Stop
1-03 Mastic (Black), East Shed Not Analyzed - Positive Stop
Willie PruittAnalyst(s):
Lab Director : Bruce Crabb Approved Signatory :
Thank you for choosing Moody Labs
Lab Manager : Heather Lopez Approved Signatory :
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. The test report shall not be reproduced except in full without written approval of the laboratory. The results relate only to the items tested. These test results do not imply endorsement by NVLAP or any agency of the U.S.
Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056-0.
This Page Left Intentionally Blank
PLM Detail Report
Project # : 26-09-00191.00
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
TTL - San Antonio
Building 2988, JBSA, Lackland AFB, 802 CES/CENME
Lab Job No. :
Report Date :
26B-01028
02/06/2026
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 300084
Chrysotile1-01 Black Mastic (Black) 100% 02/065% WP
Tar Binders1-01 Black Mastic (Black) 100% 02/0695% WP
1-02 Not Analyzed - Positive Stop 100% 02/06 WP
1-03 Not Analyzed - Positive Stop 100% 02/06 WP
SanAir ID#: 26005225
Project #: 26-0900191.00 Project Name: JSBA-Lackland AFB-Building 2988 Report Date: 2/6/2026
Analysis Report prepared for
Dear Nicholas Espino, We at SanAir would like to thank you for the work you recently submitted. The 3 sample(s) were received on Friday, January 30, 2026 via FedEx. The final report(s) is enclosed for the following sample(s): L-01, L-02, L-03.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Abisola Kasali Metals Laboratory Director SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Chemistry Analysis
- Disclaimers and Additional Information
Sample conditions:
- 3 samples in Good condition.
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
26-0900191.00Project Number:
P.O. Number:
Project Name: JSBA-Lackland AFB-Building 2988
1/22/2026Collected Date:
1/30/2026 11:30:00 AMReceived Date:
2/6/2026 9:43:29 AM
26005225 SanAir ID Number
FINAL REPORT
TTL, Inc.Name:
Address: 17215 Jones Maltsberger
San Antonio, TX 78247
210-888-6100Phone:
Analyst: Baird, Marti
Test Method: SW846/M3050B/7000B
Lead Paint Analysis PAINT µg Pb Sample Size Calculated Sample Sample
Sample Description In Sample (grams) RL Results Results
26005225 - 1 L-01 19060 0.1032 96.9 184600 18.460 % Yellow On Metal Framing / West Shed µg/g (ppm) By Weight
26005225 - 2 L-02 < 10.0 0.11 90.9 <90.9 <0.009 % Red On Wood Trim / East Shed µg/g (ppm) By Weight
26005225 - 3 L-03 < 10.0 0.1064 94 <94 <0.009 % Yellow On Wood Framing / East Shed µg/g (ppm) By Weight
Method Reporting Limit <10 µg/0.1 g paint
Signature:
Date: 2/4/2026 Date: 2/5/2026
Reviewed:
10501 Trade Ct., N. Chesterfield, VA 23236 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | LabReports@SanAir.com
26-0900191.00Project Number:
P.O. Number:
Project Name: JSBA-Lackland AFB-Building 2988
1/22/2026Collected Date:
1/30/2026 11:30:00 AMReceived Date:
2/6/2026 9:43:29 AM
26005225 SanAir ID Number
FINAL REPORT
TTL, Inc.Name:
Address: 17215 Jones Maltsberger
San Antonio, TX 78247
210-888-6100Phone:
Disclaimer
This report is the sole property of the client account named on the chain-of-custody (COC) submitted to SanAir Technologies Laboratory, Inc. (SanAir). Results in the report are confidential information intended only for the use by the customer listed on the chain of custody. Neither results nor reports will be discussed with or released to any third party without our client’s written permission. Final reports cannot be reproduced, except in full, without written approval from SanAir to assure that parts of the report are not taken out of context. This report and any information contained within shall not be edited, altered, or modified in any way by any persons or agencies receiving, viewing, distributing, or otherwise possessing a copy of this final report. The laboratory reserves the right to perform amendments to any finalized report, of which shall supersede and make obsolete any previous editions. Such changes, modifications, additions, or deletions shall be effective immediately upon notice thereof, which may be given by means including but not limited to posting on the SanAir client portal website, electronic or conventional mail, or by any other means.
The information provided in this report applies only to the samples submitted and is relevant only for the date, time, and location of sampling. The accuracy of the results of the analysis is dependent upon the method of sample procurement and information provided by the client on the COC. SanAir is not responsible for the method of sample procurement. SanAir assumes no responsibility for information provided by the client on the COC such as project number, project name, collection dates, po number, special instructions, samples collected by, sample numbers, sample identifications, sample type, selected analysis type, flow rate, total volume or area, and start stop times that may affect the validity of the results in this report.
SanAir only assures the precision and accuracy of the data it generates and assumes no responsibility for errors or biasing that occur during collection prior to SanAir’s receipt of the sample(s). Evaluation reports are based solely on the sample(s) in the condition in which they are received at the laboratory and on the information provided by the client on the COC. Sample(s) were received in good condition unless otherwise noted on the report. All quality control results are acceptable unless otherwise noted. SanAir does not make contamination corrections to reports based upon analysis of laboratory and/or field blanks. When the client requires samples to be tested that deviate from a specific method or condition, all reported results may be affected by the deviation. SanAir assumes no responsibility or liability for the manner in which the results are used or interpreted. SanAir’s Method Detection Limits (MDL) and Reporting Limits (RL) have been derived using various materials meeting each accrediting agencies’ standards. All samples are disposed of after 60 days unless otherwise requested by the client. For Lead Exposure Limits, refer to HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards and State and Federal Regulations, where applicable.
SanAir Technologies Laboratory, Inc. participates in the Environmental Lead Accreditation Program (ELAP) administered by AIHA LAP, LLC (Laboratory ID LAP-162952), and has met the EPA's NLLAP program standards. SanAir also participates in the State of New York’s DOH-ELAP program (NY Lab Id No. 11983) for lead in paint. This report does not constitute nor shall be used by the client to claim product, process, system, or person certification, approval, or endorsement by AIHA LAP, LLC, NELAC, NIST, and/or any other U.S. governmental agencies. All or some test results contained in this report may not be accredited by every local, state or federal regulatory agency. Refer to the SanAir website at www.sanair.com for copies of current certificates and scopes of various accreditations, certifications, and licenses or contact the laboratory for inquiries regarding the status or scope of an accreditation or certification.
AIHA LAP, LLC Lab ID: LAP-162952 New York State Department of Health Laboratory ID No: 11983 State of Connecticut Department of Public Health Environmental Laboratory Registration Number: PH-0105 Ohio Department of Health Environmental Lead Laboratory Approval Number E10049 State of Rhode Island Department of Health Environmental Lead Laboratory No LAO00371
Revision Date 3/24/2025
APPENDIX C
SITE PHOTOGRAPHS
JBSA Lackland Air Force Base – Building 2988 Hazardous Materials Survey Report
TTL Project No. 26-09-00191.00 Photo Log
© 2026 TTL, Inc. Purpose | Passion | Principles
PHOTO 1: View is of the building exterior and number plate. PHOTO 2: View is of the east shed interior.
PHOTO 3: View is of the black mastic on the ceiling inside east shed. (ACM)
PHOTO 4: View is of the west shed interior.
JBSA Lackland Air Force Base – Building 2988 Hazardous Materials Survey Report
TTL Project No. 26-09-00191.00 Photo Log
© 2026 TTL, Inc. Purpose | Passion | Principles
PHOTO 5: View is of yellow paint on wood framing. PHOTO 6: View is of red paint on wood trim.
PHOTO 7: View is of the west shed exterior. PHOTO 8: View is of yellow lead-based paint on metal framing.
APPENDIX D
LICENSES / CERTIFICATIONS
Name:
License Type:
License Status:
Expiry Date:
Effective Rank Date:
License Number: 603987 Current Date: 02/06/2026 01:48 PM
SALAHUDDIN, DEBORAH AKUA
Asbestos Inspector
Current
01/24/2028
01/25/2022
Addresses Mailing Address Address
SALAHUDDIN, DEBORAH AKUA
SAN ANTONIO , TX
BEXAR
78224
US
Phone Number:
2106830332
| JBSA 2988-A-1 2988 ACM.pdf |
| Sheets and Views |
| A-1 2988 ACM |
| JBSA 2988-A-2 2988 LBP.pdf |
| Sheets and Views |
| A-2 2988 LBP |
File details come from the government source that posted it. Updated .