B08_Section_J_Attachment_4_HOSP_CD_Part_lI_20231027_Reduced_Drawings.pdf
PDF 18 MB Posted
- Attached to
- HOSP 318915 Rehabilitate Park Bathhouses
- Solicitation number
- 140P2025R0004
About this file
This file appears to be a set of architectural or engineering drawings related to the rehabilitation of bathhouses at Hot Springs National Park. The drawings are likely reduced or condensed versions showing construction and renovation details for existing bathhouse facilities. Without being able to view the actual contents of the PDF, I cannot provide specific details about the individual drawings, specifications, or technical requirements contained within. This document serves as a supporting technical attachment (Section J, Attachment 4) for solicitation #140P2025R0004 issued by the Department of the Interior National Park Service.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
E E
E
E
E
M
D
E
E
E
E
J J
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
EXISTING
TELEPHONE
SERVICE
TUNNEL
B18
WORKROOM
B13
LAUNDRY
B14
TOILET
B15
ELEV. MACHINE
B22
MALE ATTENDANTS
B16
POOL VESTIBULE
B20
ELEV. PIT
B06 ELEV. LOBBY
B09
ELEV. PIT
B12
HALL
B17HALL
B02
STORAGE
B03
TOILET
B04
FEMALE ATTENDANTS
B05
POOL
B10
HALL
B11
STORAGE
B07
BOILER ROOM
B08
BASEMENT RM.
B01
CRAWL SPACE (CONFINED SPACE -
PERMIT REQUITED FOR ENTRY)
B19
EXISTING ELEVATOR EQUIPMENT
IS EXISTING TO REMAIN.
FCU-B-2M/11
FCU-B-3M/8
FCU-B-1M/9
FCU-B-4M/10
SP-1M/14
SP-2M/13,15,17
W/1
W/3
EXISTING FIBER
SERVICE
60"/7
DHU-1M/MDP-8
EXISTING ELEVATOR
EXISTING ELEVATOR
DISCONNECT
FCU-B-5M/12
MSB-3
EXISTING ELEVATOR
CAB LIGHTS &
RECEP
EXISTING SUMP PUMP
CONTROL PANEL
EXISTING FCU
EXISTING ELEVATOR
CAB LIGHTS &
RECEP DISCONNECT
EXISTING EXHAUST
FAN
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP1.0
BASEMENT POWER PLAN
01EP1.0 1/8" = 1'-0"
1 BASEMENT POWER PLAN
0 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. REFER TO MECHANICAL PLANS FOR ALL
MECHANICAL EQUIPMENT LOCATIONS.
3. ALL POWER CIRCUITS ON THIS SHEET SHALL
BE CONNECTED TO PANEL MLB, UNLESS
NOTED OTHERWISE.
4. ALL POWER, SECURITY AND LOW-VOLTAGE
WIRING SHALL BE INSTALLED IN CONDUIT.
PIP
WMM
PIP
KEYNOTES:
1. ADDRESSABLE MOTION / INTRUSION SENSOR
THAT RELAYS SIGNAL TO SECURITY SYSTEM.
2. EXISTING EXHAUST FAN TO BE RECIRCUITED
TO PANEL 'MLB'.
3. FURNISH AND INSTALL NEW STANDALONE
NETWORK SWITCH FOR DATA CONNECTIONS
ON 1ST FLOOR.
4. THERMOSTAT AND HUMIDISTAT SERVING
DEHUMIDIFIER FURNISHED AND INSTALLED BY
M.C. E.C. SHALL INSTALL LOW-VOLTAGE
WIRING FROM THERMOSTAT AND HUMIDISTAT
TO DEHUMIDIFIER IN BASEMENT RM B01.
COORDINATE WITH M.C.
5. TELECOMMUNICATIONS GROUND BUSBAR
(TGB), MOUNT AT 6'-6" AFF.
DN
E
E
E
E E
E
E
E
E
M
D
M
D
E
E
E
E
E E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
SUN PORCH
WOMEN'S COOL RM
WOMEN'S PACK ROOM
MASSAGE
FIRE RATED MECHANICAL
WOMEN'S BATH HALL
114 MEN'S BATH HALL
HALL
110C
OFFICE
MEN'S PACK ROOM
MEN'S COOL ROOM
CLOAKROOM
LOBBY
HALL
110A
HALL
110B
MEN'S HALL
112B
WOMEN'S HALL
102B
WOMEN'S HALL
102A
MEN'S HALL
112A
TOILET
PANEL ML1
FIRE ALARM PANEL
SECURITY
ALARM PANEL
W/1
PANEL MLB
+42"/3 +42"/3
MDP-5
AHU-1MRF-1M/10,12,14
B-2M/11 B-1M/9
MDP-9
HWP-1M
MDP-10
HWP-2M
W/1
UP TO SECOND FLOOR
DISTRIBUTION PANEL 'MDP'.REFER
TO SHEET EP1.2 FOR CONTINUATION.
DOWN BELOW TO EXISTING
ELEVATOR DISCONNECT.
SWITCHBOARD MSB
UVC/7
LIGHTS/8
MSB-1
CH-1M
NAC-1/13
RF-1M TCP/16
AHU-1M TCP/18
ACC-2M/MDP-12
C1
C1
C1
ACCU-1M/17,19
UTILITY TRANSFORMER
500kVA
C1
FCU-1-1M/21
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP1.1
FIRST FLOOR POWER PLAN
01EP1.1 1/8" = 1'-0"
1 FIRST FLOOR POWER PLAN
0 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. REFER TO MECHNICAL PLANS FOR ALL
MECHANICAL EQUIPMENT LOCATIONS.
3. ALL POWER CIRCUITS ON THIS SHEET SHALL
BE CONNECTED TO PANEL ML1, UNLESS
NOTED OTHERWISE.
4. ALL POWER, SECURITY AND LOW-VOLTAGE
WIRING SHALL BE INSTALLED IN CONDUIT.
PIP
WMM
PIP
KEYNOTES:
1. VAV BOX POWER SUPPLY CABINET LOCATED
IN MECHANICAL 103. COORDINATE EXACT
LOCATION WITH MECHANICAL CONTRACTOR.
2. FURNISH AND INSTALL NEW CONCRETE PAD
FOR MAIN SWITCHBOARD MSB.
3. ADDRESSABLE MOTION / INTRUSION SENSOR
THAT RELAYS SIGNAL TO SECURITY SYSTEM.
4. FURNISH AND INSTALL 30AMP TOGGLE-SWITCH
DISCONNECT SWITCH FOR BOILERS.
5. FURNISH AND INSTALL INTERNAL SPD IN
SWITCHBOARD 'MSB'.
6. NEW 500KVA TRANSFORMER SHALL BE
INSTALLED IN SOUTH YARD OF HOTEL HAIL
(LOCATION SHOWN ON PLANS IS ONLY TO
INCLUDE TRANSFORMER IN SCOPE OF WORK).
RE-USE EXISTING CONDUIT RUNS TO NEW
SWITCHBOARD 'MSB'. EXTEND AND CONNECT
NEW CONDUIT AS NEEDED. COORDINATE
WORK WITH UTILITY COMPANY AND OWNER.
NOTIFY HOTEL HALE OWNER OF SHUTDOWN 1
WEEK PRIOR TO WORK.
7. PROVIDE TEMPORARY GENERATOR SERVICE
SERVING HOTEL HALE WHILE NEW 500KVA
TRANSFORMER IS BEING INSTALLED.
GENERATOR SHALL SERVE HALE FOR THE
DURATION OF THE NEW SERVICE UPGRADE.
E
E
E
E
E E
E
E
E
E
E
E E
EE
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
PANEL ML2
DISTRIBUTION PANEL MDP
MASSAGE
MASSAGE
EMPLOYEE LOUNGE
MALE STAFF
BILLIARD RM.
WOMEN'S ELEV. HALL
MEN'S ELEV. HALL
COOL ROOM
MEN'S DRESSING RM.
HALL
200B
HALL
HALL
200A
FURNISH AND INSTALL
DUCT SMOKE DETECTOR
AT UNIT AS REQUIRED.
INTERSTITIAL ATTIC
MDP-6
AHU-2M
MDP-7
AHU-3M
RF-2M/10,12,14
GFS-1/8
MDP-11
CWP-1M
UH-1M/9
UH-2M/11 UH-2M/13
CP-1/16
WH-1M/15
UVC/5
LIGHTS/7
UVC/4
LIGHTS/6
CWP TCP/17
AHU-2M TCP/19
AHU-3M TCP/18
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP1.2
SECOND FLOOR POWER
PLAN01EP1.2 1/8" = 1'-0"
1 SECOND FLOOR POWER PLAN
0 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. REFER TO MECHANICAL PLANS FOR ALL
MECHANICAL EQUIPMENT LOCATIONS.
3. ALL POWER CIRCUITS ON THIS SHEET SHALL
BE CONNECTED TO PANEL ML2, UNLESS
NOTED OTHERWISE.
4. ALL POWER, SECURITY AND LOW-VOLTAGE
WIRING SHALL BE INSTALLED IN CONDUIT.
PIP
WMM
PIP
KEYNOTES:
1. VAV BOX POWER SUPPLY CABINET LOCATED
IN ELECTRICAL 203. COORDINATE EXACT
LOCATION WITH MECHANICAL CONTRACTOR.
2. PROVIDE TOGGLE-SWITCH DISCONNECT
SWITCH FOR WATER HEATER 'WH-1M'.
3. PROVIDE TOGGLE-SWITCH DISCONNECT
SWITCH FOR CIRC PUMP 'CP-1'.
E
E
E
E
E
E
EE
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
RM.
HALL
UTILITY CLOSET
308A
TOILET
MEN'S ELEV. HALL
UTILITY CLOSET
304CUTILITY CLOSET
304B
TOILET
304A
HALL
WOMEN'S ELEV. HALL
ROYCROFT DEN
RM
MAURICE OFFICE
WOMEN'S LOUNGE
WOMEN;S LOUNGE
MEN'S LOUNGE
MEN'S LOUNGE
FCU-3-1M/16
FCU-3-2M/14
FCU-3-10M/13
FCU-3-11M/15
FCU-3-9M/11
FCU-3-8M/9
FCU-3-4M/10
FCU-3-3M/12
FCU-3-5M/8
FCU-3-7M/7
FCU-3-6M/17
3 3
PANEL ML3
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP1.3
THIRD FLOOR POWER
PLAN01EP1.3 1/8" = 1'-0"
1 THIRD FLOOR POWER PLAN
0 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. REFER TO MECHANICAL PLANS FOR ALL
MECHANICAL EQUIPMENT LOCATIONS.
3. ALL POWER CIRCUITS ON THIS SHEET SHALL
BE CONNECTED TO PANEL ML3, UNLESS
NOTED OTHERWISE.
4. ALL POWER, SECURITY AND LOW-VOLTAGE
WIRING SHALL BE INSTALLED IN CONDUIT.
PIP
WMM
PIP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
W/1
EF-1M/19
HP-1M/18,20,22
W/1
IU-1M
IU-3M
IU-2M
IU-4M
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP1.4
ROOF POWER PLAN
01EP1.4 1/8" = 1'-0"
1 ROOF POWER PLAN
0 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. REFER TO MECHANICAL PLANS FOR ALL
MECHANICAL EQUIPMENT LOCATIONS.
3. ALL POWER CIRCUITS ON THIS SHEET SHALL
BE CONNECTED TO PANEL ML3, UNLESS
NOTED OTHERWISE.
4. ALL POWER, SECURITY AND LOW-VOLTAGE
WIRING SHALL BE INSTALLED IN CONDUIT.
PIP
WMM
PIP
KEYNOTES:
1. REFER TO M1.4 FOR EXACT LOCATION OF
CONDENSING UNIT ON ROOF.
2. FURNISH AND INSTALL 100AMP, 3P NON-FUSED
DISCONNECT SWITCH IN NEMA-3R
ENCLOSURE.
3. E.C. SHALL FURNISH AND INSTALL WIRE AND
CONDUIT FROM HP-1M TO INDOOR UNIT.
F
F
S
T S
F S S
H
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
TUNNEL
B18
WORKROOM
B13
LAUNDRY
B14
TOILET
B15
ELEV. MACHINE
B22
MALE ATTENDANTS
B16
POOL VESTIBULE
B20
ELEV. PIT
B06 ELEV. LOBBY
B09
ELEV. PIT
B12
HALL
B17HALL
B02
STORAGE
B03
TOILET
B04
FEMALE ATTENDANTS
B05
POOL
B10
HALL
B11
STORAGE
B07
BOILER ROOM
B08
BASEMENT RM.
B01
CRAWL SPACE (CONFINED SPACE -
PERMIT REQUITED FOR ENTRY)
B19
ELEV
ELEV
CM CM
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :3
P
M
EF1.0
BASEMENT FIRE ALARM
PLAN010 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. ALL FIRE ALARM WIRING SHALL BE INSTALLED
IN CONDUIT.
3. REFER TO FIRE PROTECTION RISER FOR
COORDINATION OF INSTALLATION OF TAMPER
SWITCH MONITOR AND FLOW SWITCH
MONITOR.
PIP
WMM
PIP
EF1.0 1/8" = 1'-0"
1 BASEMENT FIRE ALARM PLAN
KEYNOTES:
1. CONTROL MODULE FOR ELEVATOR RECALL.
2. CONTROL MODULE SHALL SHUNT-TRIP
ELEVATOR POWER IF HEAT DETECTOR SIGNAL
TRIPS.
F
S
F
F
F
F
S
F S
T S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
SUN PORCH
WOMEN'S COOL RM
WOMEN'S PACK ROOM
MASSAGE
FIRE RATED MECHANICAL
WOMEN'S BATH HALL
114 MEN'S BATH HALL
HALL
110C
OFFICE
MEN'S PACK ROOM
MEN'S COOL ROOM
CLOAKROOM
LOBBY
HALL
110A
HALL
110B
MEN'S HALL
112B
WOMEN'S HALL
102B
WOMEN'S HALL
102A
MEN'S HALL
112A
TOILET
ELEV
FURNISH AND INSTALL
DUCT SMOKE DETECTOR
AT UNIT AS REQUIRED.
C
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :3
P
M
EF1.1
FIRST FLOOR FIRE ALARM
PLAN010 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. ALL FIRE ALARM WIRING SHALL BE INSTALLED
IN CONDUIT.
3. REFER TO FIRE PROTECTION RISER FOR
COORDINATION OF INSTALLATION OF TAMPER
SWITCH MONITOR AND FLOW SWITCH
MONITOR.
PIP
WMM
PIP
EF1.1 1/8" = 1'-0"
1 FIRST FLOOR FIRE ALARM PLAN
S
FF
S
T S
F S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
MASSAGE
MASSAGE
EMPLOYEE LOUNGE
MALE STAFF
BILLIARD RM.
WOMEN'S DRESSING
WOMEN'S ELEV. HALL
MEN'S ELEV. HALL
COOL ROOM
MEN'S DRESSING RM.
HALL
200B
HALL
HALL
200A
ELEV
FURNISH AND INSTALL
DUCT SMOKE DETECTOR
AT UNIT AS REQUIRED.
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :4
P
M
EF1.2
SECOND FLOOR FIRE
ALARM PLAN010 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. ALL FIRE ALARM WIRING SHALL BE INSTALLED
IN CONDUIT.
3. REFER TO FIRE PROTECTION RISER FOR
COORDINATION OF INSTALLATION OF TAMPER
SWITCH MONITOR AND FLOW SWITCH
MONITOR.
PIP
WMM
PIP
EF1.2 1/8" = 1'-0"
1 SECOND FLOOR FIRE ALARM PLAN
S F
S T
S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
I
RM.
HALL
UTILITY CLOSET
308A
TOILET
MEN'S ELEV. HALL
UTILITY CLOSET
304CUTILITY CLOSET
304B
TOILET
304A
HALL
WOMEN'S ELEV. HALL
ROYCROFT DEN
RM
MAURICE OFFICE
WOMEN'S LOUNGE
WOMEN;S LOUNGE
MEN'S LOUNGE
MEN'S LOUNGE
ELEV
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :4
P
M
EF1.3
THIRD FLOOR FIRE ALARM
PLAN010 2 4 8 32
SCALE OF FEET
6 16 BLDG.
SHEET NOTES:
1. REFER TO SHEET E0.0 AND E0.1 FOR GENERAL
NOTES AND SYMBOLS.
2. ALL FIRE ALARM WIRING SHALL BE INSTALLED
IN CONDUIT.
3. REFER TO FIRE PROTECTION RISER FOR
COORDINATION OF INSTALLATION OF TAMPER
SWITCH MONITOR AND FLOW SWITCH
MONITOR.
PIP
WMM
PIP
EF1.3 1/8" = 1'-0"
1 THIRD FLOOR FIRE ALARM PLAN
RATED WALL
(CONSTRUCTION VARIES)
FIRE SEALANT
FIRE SEALANT
PENETRATING ITEM
PENETRATING ITEM
RATED FLOOR
(CONSTRUCTION
VARIES)
NOTES:
1. THIS GENERAL DETAIL APPLIES TO ALL ITEMS PENETRATING FIRE RATED
WALLS OR FLOORS. THE INTENT IS TO MAINTAIN THE FIRE RATING AND
TO ALLOW LONGITUDINAL MOVEMENT. REFER TO SPECIFICATION FOR
ADDITIONAL INFORMATION.
KEYNOTES:
1. SCHEDULE 5 PIPE SLEEVE EMBEDDED IN WALL OR FLOOR, OR SMOOTH
CORE DRILL. EACH CONTRACTOR FURNISHES SLEEVE TO G.C.,
COORDINATES SLEEVE LOCATIONS AND DEBURS SLEEVE. G.C. BUILDS
SLEEVE INTO WALL OR FLOOR ALLOWING NO GAP AROUND SLEEVE. IF
SLEEVE IS NOT PROVIDED WHEN WALL OR FLOOR IS BUILT,
CONTRACTOR SHALL INSTALL SLEEVE. SLEEVE SIZE SHALL ALLOW
ANNULAR SPACE REQUIRED BY THE SELECTED FIRE STOP SYSTEM.
2. INSTALL BACKING MATERIAL, SUCH AS MINERAL WOOL SAFING, AS
REQUIRED FOR FIRE STOP SYSTEM. INSTALL IN ACCORDANCE WITH FIRE
STOP SYSTEM APPLICATION LISTING. SECURE TO WALL OR FLOOR TO
ALLOW LONGITUDINAL MOVEMENT OF PENETRATING ITEM WITHOUT
MOVEMENT OF FIRE BARRIER.
3. WATER-TIGHT WELDED 1"x1" 20 GAUGE MINIMUM GALVANIZED SHEET
METAL ANGLE FRAME, BY CONTRACTOR IN EQUIPMENT ROOMS FOR
WATER STOP. PLACE A BEAD OF WATERPROOF SEALANT BETWEEN
FLOOR AND BOTTOM OF ANGLE FRAME. SECURE TO FLOOR WITH
MASONRY ANCHORS IN CORNERS AND ON 12" MAXIMUM CENTERS.
MULTIPLE PENETRATING ITEMS MAY BE ENCLOSED IN ONE FRAME.
12"
WALL WITH INSULATION
FLANGES ON EACH SIDE
OF WALL. CAULK AT
WALL AND SLEEVE.
CONDUIT
SHEET METAL SLEEVE, 2"
LARGER THAN CONDUIT
OVERALL DIAMETER
PACK AROUND CONDUIT WITH
FIBERGLASS INSULATION
ESCUTCHEON PLATES
ON BOTH SIDES
1/2"Ø (TYP)
GROUND BAR, INSULATORS, BRACKETS
AND BONDING PROVIDED BY E.C.
TWO HOLE COMPRESSION LUG
#6 COPPER GROUND CONDUCTOR
FROM BUILDING SERVICE GROUND
MOLDED POLYESTER -
FIBERGLASS INSULATOR
4"
NOTES:
1. MOUNT BAR AT +6'-6" A.F.F.
2. STANDOFF INSULATORS MUST BE PROVIDED WHEN ZONING THE BAR.
GROUNDING ELECTRODE
CONDUCTOR FROM SYSTEM GROUND
CONNECTION
EXOTHERMIC WELD OR HYDRAULIC
ONE SHOT CRIMP CONNECTION. (TYP
ALL GROUND WIRE CONNECTIONS)
BARE COPPER GROUNDING
CONDUCTOR (TYP)
3/4"x10'-0" COPPER OR COPPERCLAD
STEEL GROUND ROD. TOP OF GROUND
ROD SHALL BE 12" BELOW GRADE. (TYP)
20' M
INIMUM
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :3
P
M
E5.0
ELECTRICAL DETAILS
NO SCALE
FIRE BARRIER PENETRATION
NO SCALE
CONDUIT WALL PENETRATION
2 NO SCALE
GROUND BAR (GB) AND
INTERSYSTEM BONDING
TERMINAL (IBT) DETAIL
NO SCALE
GROUND GRID DETAIL
PIP
WMM
SYSTEM INPUTS
SEQUENCE OF
OPERATION
P A
N E
L /A
N N
U N
C
IA
T O
R A
L A
R M
I N
D
IC
A T
IO
N
P A
N E
L /A
N N
U N
C
IA
T O
R S
U P
E R
V
IS
O R
Y I N
D
IC
A T
IO
N
P A
N E
L /A
N N
U N
C
IA
T O
R T
R O
U B
L E
I N
D
IC
A T
IO
N
A U
D
IB
L E
A L A
R M
Q U
E N
C E
V
IS
U A
L A
L A
R M
Q U
E N
C E
E L E
C T
R
IC
S P
R
IN
K L
R
B
L L S
E Q
U E
N C
E
FIRE ALARM PANEL, TRANSPONDER, NAC PANEL
LOW BATTERY
FIRE ALARM PANEL, TRANSPONDER, NAC PANEL
BATTERY OR CHARGER FAILURE
FIRE ALARM PANEL, TRANSPONDER, NAC PANEL
ABNORMAL SWITCH OR CONTROL POSITION.
FIRE ALARM PANEL, TRANSPONDER, NAC PANEL
GROUND FAULT, OPEN CIRCUIT, SHORT CIRCUIT
FIRE ALARM PANEL, TRANSPONDER, NAC PANEL
AC POWER LOSS OR IRREGULARITY
INITIATING DEVICE
FAILURE OR COMMUNICATION ERROR
FIRE ALARM PANEL
MANUAL FIRE DRILL
MANUAL PULL STATION
SMOKE DETECTOR
NOTIFICATION APPLIANCE CIRCUIT OR SLC LOOP
GROUND FAULT, OPEN CIRCUIT, SHORT CIRCUIT
SPRINKLER SYSTEM
FLOW SWITCH
SPRINKLER SYSTEM
MONITOR SWITCH
FT F
MM
MM
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
NOTES:
1. ALL SYSTEM EVENTS SHALL BE LOGGED AND DISPLAYED ON THE ANNUNCIATOR INTERFACE,
IF APPLICABLE. SEE SPECIFICATIONS FOR MORE INFORMATION AND DESCRIPTIONS OF
SEQUENCES OF OPERATION.
2. TOTAL EVACUATION OF OCCUPANTS IS THE STANDARD OPERATING PROCEDURE FOR THIS
FACILITY IN THE EVENT OF AN ALARM. ALL NOTIFICATION APPLIANCE CIRCUITS MUST BE
INSTALLED AND PROTECTED IN ACCORDANCE WITH THE CIRCUIT SURVIVABILITY
REQUIREMENTS DESCRIBED IN NFPA 72. SEE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
SS
S
FS
TS
CARBON MONOXIDE
DETECTOR
C X X X
M E
C H
A N
IC
A
L F
A N
H U
T D
O W
N S
E Q
U E
N C
E
CMCM
METAL FRAME OF
BUILDING OR
STRUCTURE
NEC(250.52(A)(2)
METAL
UNDERGROUND
WATER PIPE
NEC 250.52(A)(1)
INCOMING ELECTRICAL
FEEDER GROUNDING
CONDUCTOR
BONDING BUSHING IF
METALLIC CONDUIT (TYP)
NEUTRAL BUS
EQUIP. GRND. BUS
SERVICE EQUIPMENT
ENCLOSURE DISTRIBUTION
PANELBOARD
NEC 250.66
ENCLOSURE
PANELBOARD OR
DISTRIBUTION
PANELBOARD
EQUIPMENT
GROUNDING
CONDUCTOR
NEC 250.122 TABLE
EQUIP. BONDING
JUMPER PER NEC
250.102(C) OR
INSTALLED AT
FACTORY
#6 BARE CU
3/4" HWPVC
CONDUIT
NEC 250.66(A)
5/8"ø X 10'-0"
CU CLAD
STEEL
GROUND ROD
NEC 250.52(A)
(5)(b)
#4 INSULATED
COPPER
GROUNDING
CONDUCTOR. PER
NEC 250.94.
MAXIMUM 20'-0"
LENGTH.
EQUIP.
GRND.
BUS
NEUTRAL
NEC 250.66
EQUIP. GROUND.
CONDUCTOR NEC
TABLE 250.122
GROUNDING BAR GB OR
INTERSYSTEM BONDING
TERMINATION IBT
CONNECT TO METALLIC
WATER MAIN, WITHIN
5'-0" OF WATER SERVICE
ENTRANCE
WM
PROVIDE JUMPER
ACROSS WATER
METER
NOTES:
1. 1. REFER TO SPECIFICATION SECTION 26 05 26 GROUNDING AND BONDING.
2. LABEL ALL GROUND CONNECTIONS AT EQUIPMENT.
DIGITAL
COMMUNICATOR
DEDICATED PHONE LINE
AND IP DATA LINE
J
NAC
NOTIFICATION APPLIANCE CIRCUIT (NAC)
FAA
FACP
SIGNAL LINE CIRCUIT(SLC)
J
F
KEYNOTES:
1. REFER TO SPECIFICATION FOR REQUIREMENTS OF EACH INITIATION LOOP AND
WIRING STYLE. REFER TO FLOOR PLANS FOR DEVICES AND THEIR LOCATIONS.
2. REFER TO SPECIFICATION FOR REQUIREMENTS OF EACH NOTIFICATION
APPLIANCE CIRCUIT AND WIRING STYLE. REFER TO FLOOR PLANS FOR DEVICES
AND THEIR LOCATIONS.
3. PROVIDE NOTIFICATION APPLIANCE EXTENDER PANELS AS REQUIRED.
DETERMINATION OF NEED TO BE MADE BY FIRE ALARM VENDOR. REFER TO
SPECIFICATIONS FOR REQUIREMENTS AND ACCEPTABLE MOUNTING LOCATIONS.
NOTES:
1. THE RISER DIAGRAM IS INTENDED TO CONVEY THE TYPES OF FIRE ALARM
CONNECTIONS AND SPECIFICALLY DOES NOT INDICATE QUANTITIES, NUMBER OF
CIRCUITS REQUIRED OR DISTANCES.
2. THE COMPLETE FIRE ALARM SYSTEM SHALL MEET ALL APPLICABLE CODES AND
MANUFACTURER'S RECOMMENDATIONS.
3. CONTRACTOR SHALL COORDINATE ALL WIRE SIZES, TYPES AND REQUIREMENTS
WITH THE VENDOR PRIOR TO BID. REFER TO SPECIFICATIONS TO DETERMINE
CIRCUIT STYLES AND IF CONDUIT IS REQUIRED OR PLENUM RATED CABLE IS
ACCEPTABLE.
4. ALL +120VAC WIRING REQUIRED FOR OPERATION OF THE SYSTEM AS DESCRIBED
IN THE CONSTRUCTION DOCUMENTS SHALL BE PROVIDED BY THE ELECTRICAL
CONTRACTOR.
5. ALL NECESSARY RELAYS MAY NOT BE SHOWN ON THIS PLAN, BUT WHERE
REQUIRED FOR PROPER OPERATION OF THE SYSTEM THEY SHALL BE PROVIDED
BY THE CONTRACTOR.
6. PARTIAL EVACUATION OR RELOCATION OF OCCUPANTS IS THE STANDARD
OPERATING PROCEDURE FOR THIS FACILITY IN THE EVENT OF AN ALARM.
THEREFORE, ALL NOTIFICATION APPLIANCE CIRCUITS MUST BE INSTALLED AND
PROTECTED IN ACCORDANCE WITH THE CIRCUIT SURVIVABILITY REQUIREMENTS
DESCRIBED IN NFPA 72. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
7. ALL WIRING SHALL BE INSTALLED IN CONDUIT.
8. FIRE ALARM SYSTEM NEEDS TO GO OUT TO NATIONAL PARK SERVICES DISPATCH
CENTER UTILIZING BOSCH 6600 RECEIVER.
F
F
F
F
NOTIFICATION APPLIANCE CIRCUIT (NAC)
S
NOTIFICATION APPLIANCE CIRCUIT (NAC)
NOTIFICATION APPLIANCE CIRCUIT (NAC)
DIGITAL
COMMUNICATOR
DEDICATED PHONE LINE
AND IP DATA LINE
SECURITY
ALARM
PANEL
NOTES:
1. THE RISER DIAGRAM IS INTENDED TO CONVEY THE TYPES OF SECURITY ALARM
CONNECTIONS AND SPECIFICALLY DOES NOT INDICATE QUANTITIES, NUMBER OF
CIRCUITS REQUIRED OR DISTANCES.
2. CONTRACTOR SHALL COORDINATE ALL WIRE SIZES, TYPES AND REQUIREMENTS
WITH THE VENDOR PRIOR TO BID. REFER TO SPECIFICATIONS TO DETERMINE
CIRCUIT STYLES AND IF CONDUIT IS REQUIRED OR PLENUM RATED CABLE IS
ACCEPTABLE.
3. ALL +120VAC WIRING REQUIRED FOR OPERATION OF THE SYSTEM AS DESCRIBED
IN THE CONSTRUCTION DOCUMENTS SHALL BE PROVIDED BY THE ELECTRICAL
CONTRACTOR.
4. ALL WIRING SHALL BE INSTALLED IN CONDUIT.
5. SECURITY ALARM SYSTEM NEEDS TO GO OUT TO NATIONAL PARK SERVICES
DISPATCH CENTER UTILIZING BOSCH 6600 RECEIVER.
SECURITY DEVICES.
REFER TO PLANS.
REFER TO SPECIFICATIONS
FOR WIRING AND DEVICES.
TELECOM SERVICE ENTRANCE CONDUIT.
REFER TO PLANS FOR ADDITIONAL
INFORMATION.
EXISTING DATA
EQUIPMENT
BOARD - POOL
VESTIBULE B20
NOTES:
1. THE RISER DIAGRAM IS INTENDED TO CONVEY THE TYPES OF COMMUNICATION
CONNECTIONS AND SPECIFICALLY DOES NOT INDICATE QUANTITIES, NUMBER OF
CIRCUITS REQUIRED OR DISTANCES.
2. ALL WIRING SHALL BE INSTALLED IN CONDUIT.
4-PAIR CATEGORY 6 UNSHIELDED
TWISTED PAIR CABLE. REFER TO
SPECIFICATIONS.
C4
TOP VIEW
SECTION "A-A"
M
IN
6"
18"
BETWEEN PIERS
8'-6" MAXIMUM 18"
D E
P T
H
4" 16"CUBICLE -8"
SWITCHBOARD +12"
S W
IT
C
H B
O A
R D
ANCHOR BOLTS PER
MANUFACTURERS
RECOMMENDATIONS
"A" "A"
CONCRETE BASE (3000 PSI)
MINIMUM 28 DAY STRENGTH
6% AIR ENTRAINED +/- 1%
5/8" CHAMFER
FINAL GRADE
(4) - 1/2" DIAMETER
REINFORCING ROD
RIGID METAL CONDUIT (RMC)
OR REINFORCED THERMOSET
RESIN CONDUIT (RTRC). LONG
SWEEP ELBOWS (TYP)
(2) 6"X6" - W4.5X4.5 WWF
1/2" DIAMETER
REINFORCING ROD
NOTES:
1. VERIFY FINAL REQUIREMENTS WITH UTILITY COMPANY PRIOR
TO INSTALLATION.
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :3
P
M
E5.1
ELECTRICAL DETAILS
NO SCALE
FIRE ALARM OPERATION MATRIX
NO SCALE
ELECTRICAL SYSTEM GROUNDING DETAIL
PIP
WMM
PIP
NO SCALE
FIRE ALARM RISER
NO SCALE
SECURITY ALARM RISER
NO SCALE
DATA AND COMMUNICATION RISER DIAGRAM
5NO SCALE
SWITCHBOARD PAD DETAIL
BASEMENT
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
ROOF
120/208V,3Ø4W
ISC 12.32 kA SCCR 18 kA
100A MLO
MLB
120/208V,3Ø4W
ISC 12.32 kA SCCR 18 kA
100A MLO
ML1
120/208V,3Ø4W
ISC 7.46 kA SCCR 10 kA
100A MLO
ML2
120/208V,3Ø4W
ISC 21.11 kA SCCR 35 kA
1000A MCB
MDP
120/208V,3Ø4W
ISC 6.77 kA SCCR 10 kA
100A MLO
ML3
E
CH-1M
182.65 kVA
E
EXISTING ELEVATOR
31.90 kVA
120/208V,3Ø4W
ISC 26.00 kA SCCR 35 kA
1200A MCCB
MSB
TRANSFORMER
500KVA
12470/7200:120/208V
(3) SETS OF 4#500 & 1#2/0 EGC EACH IN 3-1/2" C.
4#1 & 1#8 EGC IN 2" C.
4#1 & 1#8 EGC IN 2" C.
4#1 & 1#8 EGC IN 2" C.
4#1 & 1#8 EGC IN 2" C.
(2) SETS OF 3#350 & 1#1 EGC EACH IN 3" C.
(4) SETS OF 4#350 & 1#3/0 EGC IN 3" C.
EXISTING 3" CONDUIT TO REMAIN.
PULL NEW (4) SETS OF 4#350 & 1#3/0
GND THROUGH EXISTING CONDUIT.
INTERCEPT EXISTING CONDUIT PATH
AND MAKE NEW CONNECTION AS
NEEDED.
NEW UTILITY TRANSFORMER
LOCATED IN SOUTH YARD OF HOTEL
HAIL. RE-USE EXISTING CONCRETE
PAD.
3#3/0 & 1#6 EGC IN 2" C.
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP6.0
ELECTRICAL RISER
PIP
WMM
PIP
NO SCALE
ELECTRICAL RISER DIAGRAM
DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP6.1
ELECTRICAL SCHEDULES
PIP
WMM
PIP
CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURER LISTED IS THE BASIS OF DESIGN.
VERIFY AND COORDINATE ALL CEILING TYPES WITH LUMINAIRE MOUNTING AND TRIM REQUIREMENTS PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER.
CONFIRM ALL COLORS AND FINISHES OF ALL LUMINAIRE COMPONENTS WITH ARCHITECT AND INTERIOR DESIGNER PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER.
UNLESS INDICATED ON LIGHTING PLANS OR BELOW, REFER TO ARCHITECTURAL AND INTERIOR DESIGN ELEVATIONS, SECTIONS AND DETAILS FOR ALL SUSPENDED AND WALL MOUNTED LUMINAIRE MOUNTING HEIGHTS.
DMX - DIGITAL MULTIPLEX EM - EMERGENCY BATTERY ML - MULTI-LEVEL SWITCHING O - OTHER (SEE DESCRIPTION)
DALI - DIGITAL ADDRESSABLE ELV - ELECTRONIC LOW VOLTAGE LINE - LINE VOLTAGE DIMMING REM - REMOTE
0-10V - 0-10V DIMMING EB - ELECTRONIC HL - HIGH/LOW (100%/50%) STEP DIM MV - MULTI-VOLTAGE ELECTRONIC
(TYPE) DRIVER:
PL - POLE O - OTHER (SEE DESCRIPTION) DLED - DYNAMIC TUNABLE LED WLED - WARM DIM LED
P - PERIMETER WL - WALL OLED - ORGANIC LED RLED - RETROFIT LED
FR - FLANGED RECESSED UC - UNDER CABINET TLED - TUBULAR LED LAMP RGBA - COLOR CHANGING + AMBER
CV - COVE SU - SURFACE LED - LIGHT EMITTING DIODE RGBW - COLOR CHANGING + WHITE
CL - CEILING SURFACE SP - SUSPENDED (TYPE) LED RGB - COLOR CHANGING LED
(MTG) MOUNTING: RE - RECESSED (WATT) PER: FIX - FIXTURE, FT - FOOT, LAMP
CFSA - COLOR-FINISH SELECTION BY ARCHITECT [DESIGN SPECIFIC BLANKS]
PAF - PAINT AFTER FABRICATION WW - WALL WASH K - KSH12 .125" ACRYLIC O - OTHER (SEE DESCRIPTION)
FINISH: VWD - VERY WIDE G - TEMPERED GLASS SS - SEMI-SPECULAR CLEAR
RS - REGRESSED STEEL V - ANSI/IES TYPE 5 DISTRIBUTION WD - WIDE F - FROSTED ACRYLIC R - HIGH IMPACT DR ACRYLIC
RA - REGRESSED ALUMINUM IV - ANSI/IES TYPE 4 DISTRIBUTION MD - MEDIUM C - CLEAR ALZAK P - POLYCARBONATE
FS - FLAT STEEL III - ANSI/IES TYPE 3 DISTRIBUTION SP - SPOT B - BAFFLE/LOUVER N - NONE
FA - FLAT ALUMINUM II - ANSI/IES TYPE 2 DISTRIBUTION NSP - VERY NARROW SPOT A - .125" ACRYLIC M - MATTE DIFFUSE CLEAR
(DESC) DOOR: DISTRIBUTION: BEAMWIDTH: (L/L) LENS/LOUVER: K19 - KSH19 .156" ACRYLIC
LED LUMINAIRE SCHEDULE
ITEM DESCRIPTION L/L MTG
DIMENSIONS WATT LED DRIVER
MANUFACTURER AND MODELL W H DIA.
ANSI
WATTS PER TYPE QTY
DELIVERED
LUMENS
(MIN) VOLTS TYPE
A 2'x2' RECESSED TROFFER FOR LED SOURCE.
.125" FROSTED ACRYLIC LENS. FIXTURE
STEEL POST PAINTED BAKED WHITE
ENAMEL. PROVIDE WITH EMERGENCY
BATTERY PACK IF FIXTURE IS SHOWN AS
EMERGENCY.
O RE 2'-0" 2'-0" 4 1/2" 16 W FIX LED 1 3500K CCT,
2000 LUMENS,
80 CRI
120 V EB H.E. WILLIAMS 50 SERIES
E2 WALL PACK WITH EMERGENCY BATTERY
BACKUP. BLACK FINISH. BLACK CORD.
O WL 1'-0
77/256"
6 13/128" 8 205/256" 16 W FIX LED 1 3500K CCT,
1500 NOMINAL
LUMENS, 80 CRI
120 V 120V GARDCO WALL MOUNT GEO FORM
GBM LED WALL SCONCE OR
APPROVED EQUAL
EM1 EMERGENCY UNIT, TWO ADJUSTABLE
HEADS, HOUSING COLOR PER ARCHITECT.
PROVIDE WITH BATTERY BACKUP AND
SELF-DIAGNOSTIC TEST.
O WL 1'-0 1/4" 3 3/4" 4" 2 W FIX LED 1 LED 120 V EM EMERGI-LITE EL-2SQL LED OR
APPROVED EQUAL
EX1 EXIT SIGN RED LETTER, BLACK HOUSING.
PROVIDE WITH BATTERY BACKUP AND
SELF-DIAGNOSTICS TEST.
O WL/CL 1'-0 3/4" 4 5/16" 7 1/2" 3.8 W FIX LED 1 LED 120 V EM LSL LSX OR APPROVED EQUAL
G LED VAPOR TIGHT FLOODLIGHT. DURABLE
DIE-CAST ALUMINUM HOUSING. IP65 RATED.
O CL 1'-0" 6" 17.7 W FIX LED 1 3500K CCT,
1500 LUMENS,
80 CRI
120 V EB EATON ALL PRO VAPOR TIGHT
FLOODLIGHT
L1 MISSION-STYLED PENDANT. CRAFTSMAN
SIGNATURE FIXTURE, FOUR BEIGE ART
GLASS LANTERN SHADES WITH DOUBLE BAR
MISSION STYLED DESIGNS. SOLID BRASS
CHANDELIER IS COMPLEMENTED WITH
HARDWARE IN A CRAFTSMAN BROWN FINISH.
O SP 1'-10 1/2" 2'-7" 2'-7" 400 W FIX LED 1 FURNISH WITH
FOUR (4) 100
WATT LED
LAMPS. 3500K,
80 CRI
120 V MEYDA OR APPROVED EQUAL
P WALL MOUNTED MEDIUM SCOPE SCONCE
FIXTURE FOR LED SOURCE. 20 DEGREE
DOWNLIGHT OPTICS. MEDIUM OUTPUT.
COORDINATE FINISH WITH ARCHITECT.
O WL 1'-0" 6" 20 W FIX LED 1 3000K CCT,
2001 LUMENS,
80 CRI
120 V EB DELTALIGHT BOXY XL
R LED FLOOR LIGHT MOUNTED TO CONCRETE
PAD ON GROUND. MEDIUM FLOOD
DISTRIBUTION. BARN DOORS ACCESSORY
FOR GLARE REDUCTION. IP66 RATED.
COORDINATE FINISH WITH ARCHITECT.
O O 4 205/256"
1'-3" 10 51/256" 95.6 W FIX LED 1 3000K CCT,
9550 LUMENS,
80 CRI
120 V EB VISTA PRO MODEL 1059 SERIES
S4 SQUARE LENSED FIXTURE SUSPENDED AT
8'-0" AFF OR MOUNT TO CEILING, WHICHEVER
IS LOWER. UNLESS NOTED OTHERWISE ON
PLAN. FURNISH WITH BATTERY PACK WHERE
NOTED WITH EM.
A CL/SP/WL 4'-0" 2 3/4" 3 5/8" 7.5 W FT LED 1 3500K CCT,
3681 NOMINAL
LUMENS, 80 CRI
120 V 120V UTOPIA LIGHTING SS
OR APPROVED EQUAL
Z1 4.5" SHALLOW PLENEM RECESSED
DOWNLIGHT, MEDIUM DISTRIBUTION FLUSH
LENS. CLEAR SEMI-SPECULAR ANODIZED
REFLECTOR. WHITE POWDER COAT TRIM.
REMODEL KIT.
O RE 5 1/4" 4 1/2" 10.7 W FIX LED 1 3500K CCT,
1000 NOMINAL
LUMENS, 80 CRI
120 V 120V H.E. WILLIAMS 4PR LED
OR APPROVED EQUAL
NOTES:
1. {L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE.
2. [#B] PUSH BUTTON REFERS TO SCENE QUANTITY. CONTROL STATION SHALL BE CAPABLE OF [RAISE/LOWER AND] SWITCHING ON/OFF FOR MULTIPLE SCENES AS INDICATED ON SHEETS AND THE LIGHTING SEQUENCE OF OPERATIONS {L##}.
COORDINATE QUANTITIES OF BUTTONS FOR CONTROL STATIONS WITH LIGHTING CONTROL MANUFACTURER.
3. [Z#] DENOTES LIGHTING CONTROL ZONE. PROVIDE SEPARATE CONTROL OF EACH CONTROLLED ZONE. LUMINAIRES ASSOCIATED WITH THE SAME ZONE SHALL OPERATE TOGETHER WITHIN THE SAME PROGRAMMED SCENE.
4. a = SWITCH DESIGNATION FOR LIGHTING CONTROL
5. VERIFY AND COORDINATE ALL TIME CLOCK SETTINGS WITH OWNER PRIOR TO FINAL PROGRAMMING.
6. VERIFY AND COORDINATE ALL PUSH BUTTON WALL DEVICES AND QUANTITIES OF INDIVIDUAL BUTTONS WITH SCENES AND
ZONES PER LOCATION.
7. VERIFY AND COORDINATE ALL PUSH BUTTON QUANTITIES AND SCENE NAMES WITH OWNER PRIOR TO SUBMITTING
ENGRAVING TEMPLATE TO MANUFACTURER.
LIGHTING SEQUENCE OF OPERATION
PLAN ID LIGHTING SWITCHED
{LS1} Sequence: Switched lights are vacancy controlled in this space.
ON: The lights turn on manually via lighting switch.
OFF: After the space has been vacant for 20 minutes, the lights will turn off automatically via occupancy sensor or manually via lighting switch.
{LS2} Sequence: Switched lights are controlled in this space.
ON: The lights turn on using switches.
OFF: The lights turn off using switches.
{LS3} Sequence: Switched lights are vacancy controlled in this space.
ON: The lights turn on automatiically via occupancy sensor.
OFF: After the space has been vacant for 20 minutes, the lights will turn off automatically via occupancy sensor.
{PC1} Sequence: Switched lights are controlled in this space.
ON: The lights turn on using photocell.
OFF: The lights turn off using photocell.
CIRCUIT KEY NOTES: A - FURNISH WITH SHUNT-TRIP CIRCUIT BREAKER.
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 989.7 A
TOTAL CONNECTED AMPS: 989.81 A
Receptacles 10.1 kVA 99.50% 10.05 kVA TOTAL ESTIMATED DEMAND LOAD: 356.547 kVA
Power 340.563 kVA 100.00% 340.563 kVA TOTAL CONNECTED LOAD: 356.60 kVA
Lighting 5.934 kVA 100.00% 5.934 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY (INCLUDES ALL TUBS IN THIS PANEL)
6 SPARE 0 kVA 3 200 A 200 A -- -- -- --
5 SPARE 0 kVA 3 400 A 400 A -- -- -- --
4 SPD 0 kVA 3 100 A 60 A -- -- -- --
3 ELEVATOR: ELEV MACHINE B22 31.9 kVA 3 250 A 200 A 3#3/0 & 1#6 EGC IN 2" C. A
2 MDP 142.05 kVA 3 1,000 A 1,000 A (3) SETS OF 4#500 & 1#2/0 EGC EACH IN 3-1/2" C.
1 CHILLER 182.65 kVA 3 800 A 600 A (2) SETS OF 3#350 & 1#1 EGC EACH IN 3" C.
CKT LOAD DESCRIPTION Load POLES FRAME TRIP TYPE ACC. WIRE AND RACEWAY
CIRCUIT
KEY
NOTES: 1. ALL CIRCUIT BREAKERS SHALL HAVE LSI ADJUSTMENT. 2. SELECTIVE COORDINATION IS REQUIRED WITH EXTERIOR MAIN CIRCUIT BREAKER. 3.
PROVIDE WITH METERING FOR ALL CIRCUIT BREAKERS.
ISC: 26.00 kA
SCCR: 35 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA 3R SOLID NEUTRAL VOLTS: 120/208 Wye
MAIN: 1,200 A MCCB
SWITCHBOARD MSB
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 394.1 A
TOTAL CONNECTED AMPS: 394.28 A
Receptacles 10.1 kVA 99.50% 10.05 kVA TOTAL ESTIMATED DEMAND LOAD: 141.997 kVA
Power 126.013 kVA 100.00% 126.013 kVA TOTAL CONNECTED LOAD: 142.05 kVA
Lighting 5.934 kVA 100.00% 5.934 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY (INCLUDES ALL TUBS IN THIS PANEL)
22 SPACE -- 3 -- -- -- -- -- --
21 SPACE -- 3 -- -- -- -- -- --
20 SPACE -- 3 -- -- -- -- -- --
19 SPACE -- 3 -- -- -- -- -- --
18 SPACE -- 3 -- -- -- -- -- --
17 SPARE 0 kVA 3 100 A 30 A -- -- -- --
16 SPARE 0 kVA 3 100 A 40 A -- -- -- --
15 SPARE 0 kVA 3 100 A 40 A -- -- -- --
14 SPARE 0 kVA 3 150 A 100 A -- -- -- --
13 SPARE 0 kVA 3 150 A 100 A -- -- -- --
12 ACC-2M: UTIL YARD 1.48 kVA 3 100 A 20 A 3#12 & 1#12 EGC IN 3/4" C.
11 CWP-1M: MECH 203 8.8 kVA 3 100 A 50 A 3#6 & 1#10 EGC IN 1" C.
10 HWP-2M: MECH 103 6.1 kVA 3 100 A 30 A 3#10 & 1#10 EGC IN 3/4" C.
9 HWP-1M: MECH 103 6.1 kVA 3 100 A 30 A 3#10 & 1#10 EGC IN 3/4" C.
8 DHU-1M: BOILER RM B08 10.81 kVA 3 100 A 45 A 3#6 & 1#10 EGC IN 1" C.
7 AHU-3M: SECOND FLOOR 4.72 kVA 3 100 A 25 A 3#10 & 1#10 EGC IN 3/4" C.
6 AHU-2M: SECOND FLOOR 11.78 kVA 3 100 A 40 A 3#8 & 1#10 EGC IN 3/4" C.
5 AHU-1M: FIRST FLOOR 25.04 kVA 3 100 A 80 A 3#3 & 1#8 EGC IN 1 1/4" C.
4 ML3: THIRD FLOOR 33.22 kVA 3 150 A 100 A 4#1 & 1#8 EGC IN 2" C.
3 ML2: SECOND FLOOR 8.38 kVA 3 150 A 100 A 4#1 & 1#8 EGC IN 2" C.
2 ML1: FIRST FLOOR 11.94 kVA 3 150 A 100 A 4#1 & 1#8 EGC IN 2" C.
1 MLB: BASEMENT 13.68 kVA 3 150 A 100 A 4#1 & 1#8 EGC IN 2" C.
CKT LOAD DESCRIPTION Load POLES FRAME TRIP TYPE ACC. WIRE AND RACEWAY
CIRCUIT
KEY
NOTES: PROVIDE METERING FOR ALL CIRCUIT BREAKERS.
ISC: 21.11 kA
SCCR: 35 kA
LOCATION: ELECTRICAL B01D WIRE: 4
FED FROM: 1,000 A/3P @ MSB GROUND BUS PHASE: 3
ENCLOSURE: NEMA 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MAIN: 1,000 A MCB
DISTRIBUTION PANEL MDP
EXTERIOR
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP6.2
ELECTRICAL SCHEDULES
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 38 A
TOTAL CONNECTED AMPS: 37.98 A
Receptacles 2.18 kVA 100.00% 2.18 kVA TOTAL ESTIMATED DEMAND LOAD: 13.683 kVA
Power 10.02 kVA 100.00% 10.02 kVA TOTAL CONNECTED LOAD: 13.68 kVA
Lighting 1.483 kVA 100.00% 1.483 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 42.24 33.55 39.94
Total Load: 4.97 kVA 4.03 kVA 4.69 kVA
-- 41 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 42 --
-- 39 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 40 --
-- 37 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 38 --
-- 35 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 36 --
-- 33 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 34 --
-- 31 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 32 --
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
19 EX. EF-1: BASEMENT RM B01 20 A 1 12 12 12 0.7 0.67 12 12 12 1 20 A EX. FCU: ELEV MACHINE B22 20
-- 17 -- -- -- -- -- -- 1.27 1 12 12 12 1 20 A EX. SP PUMP CONTROL: BOILER RM B08 18
-- 15 -- -- -- -- -- -- 1.27 0.5 12 12 12 1 20 A ELEV CAB LTS & RECEP: ELEV PIT B12 16
13 SP-2M: BASEMENT RM B01 20 A 3 12 12 12 1.27 0.2 12 12 12 1 20 A SP-1M: STORAGE B07 14
11 FCU-B-2M: FEMALE ATT. B05 20 A 1 12 12 12 0.67 0.67 12 12 12 1 20 A FCU-B-5M: BOILER RM B08 12
9 FCU-B-1M: BASEMENT RM B01 20 A 1 12 12 12 0.67 0.67 12 12 12 1 20 A FCU-B-4M: MALE ATT. B16 10
7 REC: IT EQUIP 20 A 1 12 12 12 0.36 0.67 12 12 12 1 20 A FCU-B-3M: POOL VESTIBULE B20 8
5 LTS: BASEMENT LTG 20 A 1 10 10 10 0.77 0.31 12 12 12 1 20 A LTS: BASEMENT CORRIDOR LTG 6
3 REC: RMS B02, B11, B17, B20, EXTERIOR 20 A 1 12 12 12 0.72 0.2 12 12 12 1 20 A LTS: OVERALL STAIR 2 4
1 REC: RMS B01, B08, B14, B15, B19 20 A 1 12 12 12 0.9 0.2 12 12 12 1 20 A LTS: OVERALL STAIR 1 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC: 12.32 kA
SCCR: 18 kA
LOCATION: BASEMENT RM. B01 WIRE: 4
FED FROM: 100 A/3P @ MDP GROUND BUS PHASE: 3
ENCLOSURE: NEMA 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MLO
PANEL MLB
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 33.2 A
TOTAL CONNECTED AMPS: 33.15 A
Receptacles 3.6 kVA 100.00% 3.6 kVA TOTAL ESTIMATED DEMAND LOAD: 11.944 kVA
Power 7.35 kVA 100.00% 7.35 kVA TOTAL CONNECTED LOAD: 11.94 kVA
Lighting 0.994 kVA 100.00% 0.994 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 39.96 31.68 28.69
Total Load: 4.75 kVA 3.75 kVA 3.44 kVA
-- 41 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 42 --
-- 39 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 40 --
-- 37 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 38 --
-- 35 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 36 --
-- 33 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 34 --
-- 31 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 32 --
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
21 FCU-1-1M: MECH 103 20 A 1 12 12 12 1.13 0 -- -- -- 1 20 A SPARE 22 --
-- 19 -- -- -- -- -- -- 1.11 0.2 12 12 12 1 20 A FIRE ALARM PNL: CLOAK RM 117 20
17 EX. ACCU-1M: NORTHEAST YARD 25 A 2 10 10 10 1.11 0.2 12 12 12 1 20 A AHU-1M TCP: MECH 103 18
15 SECURITY ALARM PNL: MECH 103 20 A 1 12 12 12 0.2 0.2 12 12 12 1 20 A RF-1M TCP: MECH 103 16
13 NAC-1: MECH 103 20 A 1 12 12 12 0.2 0.43 -- -- -- -- -- -- 14 --
11 B2-M: MECH 103 20 A 1 12 12 12 0.3 0.43 -- -- -- -- -- -- 12 --
9 B1-M: MECH 103 20 A 1 12 12 12 0.3 0.43 12 12 12 3 20 A RF-1M: MECH 103 10
7 AHU-1M UVC: MECH 103 20 A 1 12 12 12 0.3 0.3 12 12 12 1 20 A AHU-1M LTS: MECH 103 8
5 REC: RMS 109, 110C, 117 20 A 1 12 12 12 0.9 0.5 12 12 12 1 20 A VAV BOX POWER SUPPLY: MECH 103 6
3 REC: RMS 102B, 107, 108, 115 20 A 1 12 12 12 1.44 0.05 12 12 12 1 20 A LTS: FIRST FLOOR CORRIDOR LTG 4
1 REC: RMS 103, 104, 105, EXTERIOR 20 A 1 12 12 12 1.26 0.94 10 10 10 1 20 A LTS: FIRST FLOOR LTG 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC: 12.32 kA
SCCR: 18 kA
LOCATION: BASEMENT RM. B01 WIRE: 4
FED FROM: 100 A/3P @ MDP GROUND BUS PHASE: 3
ENCLOSURE: NEMA 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MLO
PANEL ML1
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
180065
318674
10.27.2023
REHABILITATE BATHHOUSES
MAURICE BATHHOUSE
A/E FIRMS
PRIME/ARCH:
STRATA ARCHITECTURE
1701 OAK STREET,
SUITE 100
KANSAS CITY, MO
T: 816.474.0900
MEP/ENG:
IMEG CORP.
1600 BALTIMORE STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:1 :5
P
M
EP6.3
ELECTRICAL SCHEDULES
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 23.3 A
TOTAL CONNECTED AMPS: 23.27 A
Receptacles 1.08 kVA 100.00% 1.08 kVA TOTAL ESTIMATED DEMAND LOAD: 8.384 kVA
Power 6.58 kVA 100.00% 6.58 kVA TOTAL CONNECTED LOAD: 8.38 kVA
Lighting 0.724 kVA 100.00% 0.724 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 33.92 22.97 15.08
Total Load: 3.94 kVA 2.63 kVA 1.81 kVA
-- 41 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 42 --
-- 39 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 40 --
-- 37 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 38 --
-- 35 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 36 --
-- 33 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 34 --
-- 31 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 32 --
-- 29 SPARE 20 A 1 -- -- -- 0 -- -- -- -- 1 -- SPACE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
19 AHU-2M TCP: MECH 203 20 A 1 12 12 12 0.2 0 -- -- -- 1 20 A SPARE 20 --
17 CHILLED WATER SYSTEM TCP: MECH 203 20 A 1 12 12 12 0.2 0.2 12 12 12 1 20 A AHU-3M TCP: MEN'S DRESS 205 18
15 WH-1M: MECH 203 20 A 1 12 12 12 0.51 0.51 12 12 12 1 20 A CP-1: MECH 203 16
13 UH-2M: ATTIC 313 20 A 1 12 12 12 0.51 0.3 -- -- -- -- -- -- 14 --
11 UH-2M: ATTIC 313 20 A 1 12 12 12 0.51 0.3 -- -- -- -- -- -- 12 --
9 UH-1M: MECH 203 20 A 1 12 12 12 0.51 0.3 12 12 12 3 20 A RF-2M: MECH 203 10
7 AHU-2M LTS: MECH 203 20 A 1 12 12 12 0.3 0.83 12 12 12 1 20 A GFS-1: MECH 203 8
5 AHU-2M UVC: MECH 203 20 A 1 12 12 12 0.3 0.3 12 12 12 1 20 A AHU-3M LTS: MEN'S DRESS 205 6
3 VAV POWER SUPPLY BOX: 2ND FL ELEC 20 A 1 12 12 12 0.5 0.3 12 12 12 1 20 A AHU-3M UVC: MEN'S DRESS 205 4
1 REC: SECOND FLOOR 20 A 1 12 12 12 1.08 0.72 10 10 10 1 20 A LTS: SECOND FLOOR 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC: 7.46 kA
SCCR: 10 kA
LOCATION: HALL 211 WIRE: 4
FED FROM: 100 A/3P @ MDP GROUND BUS PHASE: 3
ENCLOSURE: NEMA 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MLO
PANEL ML2
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 92.2 A
TOTAL CONNECTED AMPS: 92.20 A
Receptacles 3.24 kVA 100.00% 3.24 kVA TOTAL ESTIMATED DEMAND LOAD: 33.215 kVA
Power 27.242 kVA 100.00% 27.242 kVA TOTAL CONNECTED LOAD: 33.22 kVA
Lighting 2.733 kVA 100.00% 2.733 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 104.05 94.63 81.59
Total Load: 12.28 kVA 11.15 kVA 9.79 kVA
-- 41 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 42 --
-- 39 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 40 --
-- 37 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 38 --
-- 35 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 36 --
-- 33 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 34 --
-- 31 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 32 --
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
21 LTS: EXTERIOR LIGHTS 20 A 1 10 10 10 0.35 5.64 -- -- -- -- -- -- 22 --
19 EF-1M: ROOF 20 A 1 12 12 12 0.67 5.64 -- -- -- -- -- -- 20 --
17 FCU-3-6M: HALL 302 20 A 1 12 12 12 0.67 5.64 8 4 4 3 70 A HP-1M: ROOF 18
15 FCU-3-11M: WOMEN LOUNGE 304 20 A 1 12 12 12 0.83 0.67 12 12 12 1 20 A FCU-3-1M: MEN LOUNGE 306 16
13 FCU-3-10M: WOMEN LOUNGE 304 20 A 1 12 12 12 0.83 0.83 12 12 12 1 20 A FCU-3-2M: MEN LOUNGE 306 14
11 FCU-3-9M: WOMEN LOUNGE 304 20 A 1 12 12 12 0.83 0.83 12 12 12 1 20 A FCU-3-3M: MEN LOUNGE 306 12
9 FCU-3-8M: WOMEN LOUNGE 305 20 A 1 12 12 12 0.83 0.83 12 12 12 1 20 A FCU-3-4M: MEN LOUNGE 307 10
7 FCU-3-7M: WOMEN LOUNGE 305 20 A 1 12 12 12 0.83 1.66 10 10 10 1 25 A FCU-3-5M: MEN LOUNGE 307 8
5 REC: ROYCROFT DEN 300 20 A 1 12 12 12 0.9 0.92 12 12 12 1 20 A LTS: THIRD FLOOR 6
3 REC: RMS 300, 304 20 A 1 12 12 12 1.08 0.92 12 12 12 1 20 A LTS: THIRD FLOOR 4
1 REC: RMS 302, 305, 306, 309, 311, ROOF 20 A 1 12 12 12 1.26 0.55 12 12 12 1 20 A LTS: THIRD FLOOR 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC: 6.77 kA
SCCR: 10 kA
LOCATION: HALL 302 WIRE: 4
FED FROM: 100 A/3P @ MDP GROUND BUS PHASE: 3
ENCLOSURE: NEMA 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MLO
PANEL ML3
TECH. REVIEW:
DATE:
SUB SHEET NO. TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
HOT SPRINGS NATIONAL PARK
182951
318915
10.27.2023
REHABILITATE BATHHOUSES
LIBBEY BATHHOUSE
A/E FIRMS
ARCH:
QUINN EVANS
219 1/2 N. MAIN STREET
ANN ARBOR, MI
T: 734.663.5888
MEP/ENG:
IMEG CORP.
1600 BALTIMORE
STREET,
SUITE 300
KANSAS CITY, MO
T: 816.842.8437
10.27.2023
/2 /2
:5
:3
A
M
EP6.1
ELECTRICAL SCHEDULES02
CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE MANUFACTURER LISTED IS THE BASIS OF DESIGN.
VERIFY AND COORDINATE ALL CEILING TYPES WITH LUMINAIRE MOUNTING AND TRIM REQUIREMENTS PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER.
CONFIRM ALL COLORS AND FINISHES OF ALL LUMINAIRE COMPONENTS WITH ARCHITECT AND INTERIOR DESIGNER PRIOR TO THE RELEASE OF THE LUMINAIRE ORDER.
UNLESS INDICATED ON LIGHTING PLANS OR BELOW, REFER TO ARCHITECTURAL AND INTERIOR DESIGN ELEVATIONS, SECTIONS AND DETAILS FOR ALL SUSPENDED AND WALL MOUNTED LUMINAIRE MOUNTING HEIGHTS.
DMX - DIGITAL MULTIPLEX EM - EMERGENCY BATTERY ML - MULTI-LEVEL SWITCHING O - OTHER (SEE DESCRIPTION)
DALI - DIGITAL ADDRESSABLE ELV - ELECTRONIC LOW VOLTAGE LINE - LINE VOLTAGE DIMMING REM - REMOTE
0-10V - 0-10V DIMMING EB - ELECTRONIC HL - HIGH/LOW (100%/50%) STEP DIM MV - MULTI-VOLTAGE ELECTRONIC
(TYPE) DRIVER:
PL - POLE O - OTHER (SEE DESCRIPTION) DLED - DYNAMIC TUNABLE LED WLED - WARM DIM LED
P - PERIMETER WL - WALL OLED - ORGANIC LED RLED - RETROFIT LED
FR - FLANGED RECESSED UC - UNDER CABINET TLED - TUBULAR LED LAMP RGBA - COLOR CHANGING + AMBER
CV - COVE SU - SURFACE LED - LIGHT EMITTING DIODE RGBW - COLOR CHANGING + WHITE
CL - CEILING SURFACE SP - SUSPENDED (TYPE) LED RGB - COLOR CHANGING LED
(MTG) MOUNTING: RE - RECESSED (WATT) PER: FIX - FIXTURE, FT - FOOT, LAMP
CFSA - COLOR-FINISH SELECTION BY ARCHITECT [DESIGN SPECIFIC BLANKS]
PAF - PAINT AFTER FABRICATION WW - WALL WASH K - KSH12 .125" ACRYLIC O - OTHER (SEE DESCRIPTION)
FINISH: VWD - VERY WIDE G - TEMPERED GLASS SS - SEMI-SPECULAR CLEAR
RS - REGRESSED STEEL V - ANSI/IES TYPE 5 DISTRIBUTION WD - WIDE F - FROSTED ACRYLIC R - HIGH IMPACT DR ACRYLIC
RA - REGRESSED ALUMINUM IV - ANSI/IES TYPE 4 DISTRIBUTION MD - MEDIUM C - CLEAR ALZAK P - POLYCARBONATE
FS - FLAT STEEL III - ANSI/IES TYPE 3 DISTRIBUTION SP - SPOT B - BAFFLE/LOUVER N - NONE
FA - FLAT ALUMINUM II - ANSI/IES TYPE 2 DISTRIBUTION NSP - VERY NARROW SPOT A - .125" ACRYLIC M - MATTE DIFFUSE CLEAR
(DESC) DOOR: DISTRIBUTION: BEAMWIDTH: (L/L) LENS/LOUVER: K19 - KSH19 .156" ACRYLIC
LED LUMINAIRE SCHEDULE
ITEM DESCRIPTION L/L MTG
DIMENSIONS WATT LED DRIVER
MANUFACTURER AND MODELL W H DIA.
ANSI
WATTS PER TYPE QTY
DELIVERED
LUMENS
(MIN) VOLTS TYPE
E2 WALL PACK WITH EMERGENCY BATTERY
BACKUP. BLACK FINISH. BLACK CORD.
FURNISH WITH INTREGRAL PHOTOCELL.
O WL 1'-0
77/256"
6 13/128" 8 205/256"
16 W FIX LED 1 3500K CCT,
1500 NOMINAL
LUMENS, 80
CRI
120 V 120V GARDCO WALL MOUNT GEO
FORM GBM LED WALL SCONCE
OR APPROVED EQUAL
EM1 EMERGENCY UNIT, TWO ADJUSTABLE
HEADS, HOUSING COLOR PER ARCHITECT.
PROVIDE WITH BATTERY BACKUP AND
SELF-DIAGNOSTIC TEST.
O WL 1'-0 1/4" 3 3/4" 4" 2 W FIX LED 1 LED 120 V EM EMERGI-LITE EL-2SQL LED OR
APPROVED EQUAL
EX1 EXIT SIGN RED LETTER, BLACK HOUSING.
PROVIDE WITH BATTERY BACKUP AND
SELF-DIAGNOSTICS TEST.
O WL/CL 1'-0 3/4" 4 5/16" 7 1/2" 3.8 W FIX LED 1 LED 120 V EM LSL LSX OR APPROVED EQUAL
S4 SQUARE LENSED FIXTURE. SUSPEND AT 8'-0"
AFF OR MOUNT TO CEILING, WHICHEVER IS
LOWER
A CL/SP/WL 4'-0" 2 3/4" 3 5/8" 7.5 W FT LED 1 3500K CCT,
3681 NOMINAL
LUMENS, 80
CRI
120 V UTOPIA LIGHTING SS
OR APPROVED EQUAL
S8 SQUARE LENSED FIXTURE. SUSPEND AT 8'-0"
AFF OR MOUNT TO CEILING, WHICHEVER IS
LOWER. FURNISH WITH BATTERY PACK
WHERE NOTED.
A CL/SP/WL 8'-0" 3 5/8" 3 5/8" 7.5 W FT LED 1 3500K CCT,
3681 NOMINAL
LUMENS, 80
CRI
120 V UTOPIA LIGHTING SS
OR APPROVED EQUAL
NOTES:
1. {L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE.
2. [#B] PUSH BUTTON REFERS TO SCENE QUANTITY. CONTROL STATION SHALL BE CAPABLE OF [RAISE/LOWER AND] SWITCHING ON/OFF FOR MULTIPLE SCENES AS INDICATED ON SHEETS AND THE LIGHTING SEQUENCE OF OPERATIONS {L##}.
COORDINATE QUANTITIES OF BUTTONS FOR CONTROL STATIONS WITH LIGHTING CONTROL MANUFACTURER.
3. [Z#] DENOTES LIGHTING CONTROL ZONE. PROVIDE SEPARATE CONTROL OF EACH CONTROLLED ZONE. LUMINAIRES ASSOCIATED WITH THE SAME ZONE SHALL OPERATE TOGETHER WITHIN THE SAME PROGRAMMED SCENE.
4. a = SWITCH DESIGNATION FOR LIGHTING CONTROL
5. VERIFY AND COORDINATE ALL TIME CLOCK SETTINGS WITH OWNER PRIOR TO FINAL PROGRAMMING.
6. VERIFY AND COORDINATE ALL PUSH BUTTON WALL DEVICES AND QUANTITIES OF INDIVIDUAL BUTTONS WITH SCENES AND
ZONES PER LOCATION.
7. VERIFY AND COORDINATE ALL PUSH BUTTON QUANTITIES AND SCENE NAMES WITH OWNER PRIOR TO SUBMITTING
ENGRAVING TEMPLATE TO MANUFACTURER.
LIGHTING SEQUENCE OF OPERATION
PLAN ID LIGHTING SWITCHED
{LS1} Sequence: Switched lights are controlled in this space.
ON: The lights turn on manually via lighting switch.
OFF: The lights turn off manually via lighting switch.
{LS2} Sequence: Switched lights are vacancy controlled in this space.
ON: The lights shall turn on manually via lighting switch.
OFF: After the space has been vacant for 20 minutes, the lights will automatically turn off via occupancy sensor or manually via lighting switch.
{PC1} Sequence: Switched lights are controlled in this space.
ON: The lights turn on using integral photocell.
OFF: The lights turn off using integral photocell.
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 504.6 A
TOTAL CONNECTED AMPS: 504.62 A
Receptacles 4.14 kVA 100.00% 4.14 kVA TOTAL ESTIMATED DEMAND LOAD: 181.798 kVA
Power 174.764 kVA 100.00% 174.764 kVA TOTAL CONNECTED LOAD: 181.80 kVA
Lighting 2.894 kVA 100.00% 2.894 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOA…
This is the start of the file's text. The full file is on GovTribe.