This document package includes drawings and specifications for rehabilitation work at the Look Rock Campground in Great Smoky Mountains National Park. The scope of work involves replacing HVAC and plumbing systems at various campground facilities, including the campground office, comfort stations, and pump house. HVAC replacements include new ductless split systems, wall-mounted exhaust fans, and a passive wall vent. Plumbing replacements include water closets, lavatories, service sinks, water heaters, and domestic water and waste piping. The specifications provide product details for these items and instructions for demolition, installation, and commissioning of the new systems. Relevant submittals and testing requirements are also outlined.

View the file

Other files

File Type Posted
B09_Amend04_Solit_SF1442_140P2021R0007_0004.pdf PDF
Sol_140P2021R0007_Amd_0004.pdf PDF
Sol_140P2021R0007_Amd_0003.pdf PDF
B09_Amend03_Solit_SF1442_140P2021R0007_0003.pdf PDF
B09_Amend03_Attach_ConstrClause_page_0003.pdf PDF
Sol_140P2021R0007_Amd_0002.pdf PDF
B09_140P2021R0007_Amend_02-extend_0002.pdf PDF
Sol_140P2021R0007_Amd_0001.pdf PDF
B11_PreProposal Presentation_GRSM158579 202623_0001.pptx PPTX presentation
B09_140P2021R0007_Amendment_01_0001.pdf PDF
B09_140P2021R0007_Amend_01_SiteVisitAttendees_Attachment_0001.pdf PDF
B08_GRSM_158579_202623_Solit_Attach 07 - Gen Refs.doc DOC document
B08_GRSM_158579_202623_Solit_Attach 04 - Exp.docx DOCX document
B08_GRSM_158579_202623_Solit_Attach 02c - pg 21 to 30 -Drawings.pdf PDF
B08_GRSM_158579_202623_Solit_Attach 05 - Past Perf.docx DOCX document
B08_GRSM_158579_202623_Solit_Attach 01 - Specifications.pdf PDF
B08_GRSM_158579_202623_Solit_Attach_10_CROMTankInspectionReport_081820.pdf PDF
B08_GRSM158579_202623_Solit_Attach_09_GeotechReport_081820.pdf PDF
B08_GRSM_158579_202623_Solit_Attach 02a - pg 1 to 10 -Drawings.pdf PDF
B08_GRSM_158579_202623_Solit__SF1442_ConstructionClauses.pdf PDF
B08_GRSM_158579_202623_Solit_Attach 02e - pg 56 to 80 -Drawings.pdf PDF
B08_GRSM_158579_202623_Solit_Attach_08_Deliverables_LmtOnSubconRpt.xlsx XLSX spreadsheet
B08_GRSM_158579_202623_Solit_Attach 03 - WageDetermination.pdf PDF
Sol_140P2021R0007.pdf PDF
B08_GRSM_158579_202623_Solit_Attach 02b - pg 11 to 20 -Drawings.pdf PDF
B08_GRSM_158579_202623_Solit_Vol_II_PriceSchedule.xlsx XLSX spreadsheet
B08_GRSM_158579_202623_Solit_Attach 06 - SF 24 Bid Bond.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HVAC BASIC MATERIALS AND METHODS

PART 1 - GENERAL

SUMMARY

SECTION INCLUDES: BASIC MATERIALS AND METHODS GENERALLY

COMMON TO THE WORK TO PROVIDE COMPLETE, OPERATIONAL AND

FUNCTIONING AIR CONDITIONING AND VENTILATION SYSTEM

REPLACEMENT

SCOPE OF WORK

· CAMPGROUND OFFICE (KIOSK):

o REMOVE EXISTING PTAC.

o PROVIDE NEW DUCTLESS SPLIT SYSTEM HEAT PUMP COMPLETE

WITH INDOOR UNIT, OUTDOOR UNIT, AND CONTROLS.

o PROVIDE WALL MOUNTED EXHAUST FAN SERVING THE TOILET, COMPLETE WITH FAN, GRILLE, WALL CAP, SHUTTER, BIRDSCREEN, AND CONTROLS.

· COMFORT STATIONS #2 AND #3 (605 AND 607):

o PROVIDE NEW WALL MOUNTED EXHAUST FAN FOR MEN AND

WOMEN'S TOILET ROOMS, EACH COMPLETE WITH FAN, FAN

HOUSING, GRAVITY BACKDRAFT DAMPER, AND CONTROLS.

· COMFORT STATION #4 (606):

o PROVIDE NEW WALL MOUNTED EXHAUST FAN FOR MEN AND

WOMEN'S TOILET ROOMS, EACH COMPLETE WITH FAN, FAN

HOUSING, GRAVITY BACKDRAFT DAMPER, AND CONTROLS.

· PUMP HOUSE:

o REMOVE EXISTING PASSIVE WALL VENT DAMPER AND SLEEVE.

o PROVIDE NEW PASSIVE WALL VENT COMPLETE WITH WALL

SLEEVE, LOUVER, AND MANUAL CONTROL DAMPER.

SUBMITTALS

SUBMITTALS REQUIRED

· COMPLETE TECHNICAL SUBMITTALS ON ALL PRODUCTS LISTED

PER SECTION 01 33 23

· PRESSURE TEST RESULTS OF NEW REFRIGERANT PIPING

SYSTEMS

· REFRIGERANT PIPING DIAGRAM

· TEST AND BALANCE REPORT FOR ALL EQUIPMENT IN

ACCORDANCE WITH THE NATIONAL ENVIRONMENTAL BALANCING

BUREAU PROCEDURAL STANDARDS FOR TESTING ADJUSTING AND

BALANCING OF ENVIRONMENTAL SYSTEMS.

QUALITY ASSURANCE

STANDARDS: COMPLY WITH APPLICABLE NATIONAL, STATE, AND

LOCAL CODES AND STANDARDS: ASTM, ASME, ANSI, AND SMACNA.

FEDERAL SPECIFICATIONS, AWWA, CISPI, NFPA, FM GLOBAL, AND UL.

QUALIFICATIONS OF MANUFACTURER: PRODUCTS USED IN THE

WORK OF THIS SECTION SHALL BE PRODUCED BY MANUFACTURERS

REGULARLY ENGAGED IN MANUFACTURE OF SIMILAR ITEMS AND

WITH A HISTORY OF SUCCESSFUL PRODUCTION AS REVIEWED BY

THE ARCHITECT.

FIELD VERIFICATION: PROVIDE FIELD VERIFICATION OF

INSTALLATION REQUIREMENTS TO ACCOMMODATE THE NEW

EQUIPMENT AND SYSTEMS BEING INSTALLED.

PART 2 - PRODUCTS

GENERAL

PROVIDE THE FOLLOWING PRODUCTS AS A COMPLETE ASSEMBLY WITH

REQUIRED ACCESSORIES FOR A COMPLETE AND FUNCTIONING ENTITY IN

COMPLIANCE WITH GOVERNING CODES AND APPLICABLE STANDARDS AS

SPECIFIED, MANUFACTURER'S INSTRUCTIONS OR AS REQUIRED.

OMISSION OF MINOR DETAILS IN CONTRACT DOCUMENTS DOES NOT

WAIVE AND/OR OTHERWISE RELINQUISH COMPLIANCE WITH THE ABOVE

REQUIREMENTS.

MATERIALS AND MANUFACTURERS:

DUCTLESS SPLIT-SYSTEM HEAT PUMP (HP-1A & B):

BASIS OF DESIGN: MITSUBISHI, MODEL MSZ-GL09NA/MUZ-GL09NA

ALTERNATE MANUFACTURERS: LG, DAIKIN

REQUIRED FEATURES:

· MINIMUM COOLING CAPACITY (BTU/H): 8,120

· MINIMUM HEATING CAPACITY (BTU/H): 7,105

· SEER: 24.6

· EER: 15.4

· COP: 4.44

· HSPF: 12.8

· POWER SUPPLY (V/PH/HZ): 208-230/1/60

· REFRIGERANT: R410A

· REMOTE WALL MOUNT WIRELESS THERMOSTAT

· 12 INCH HIGH OUTDOOR UNIT STAND

· REFRIGERANT LINE SET KIT WITH SOFT COPPER TUBING AND

ARMAFLEX INSULATION OR EQUAL.

· INDOOR/OUTDOOR PVC LINE SET COVERING KIT.

· FACTORY CERTIFIED TECHNICIAN STARTUP AND REPORT

· DEMONSTRATION AND TRAINING TO SITE ENGINEER

TOILET EXHAUST FANS:

EF-1

BASIS OF DESIGN: PANASONIC, MODEL FV-08WQ1

ALTERNATE MANUFACTURERS: GREENHECK, COOK

· MINIMUM AIR FLOW: 50 CFM

· EXT. STATIC PRESSURE: 0.125 IN WG

· FAN RPM: 660

· MOTOR SIZE: 1/40 HP

· VOLTS/PH/HZ: 120/1/60

REQUIRED FEATURES:

· DIRECT-DRIVE

· RUST-PROOF FAN HOUSING

· INTERIOR INTAKE GRILLE

· EXTERIOR EXHAUST HOOD

· BUILT-IN SPRING SHUTTER WITH FOAM SEAL

· BIRDSCREEN

· FACTORY CERTIFIED TECHNICIAN STARTUP AND REPORT

EF-2A & B, 3A & B, 4A & B

BASIS OF DESIGN: GREENHECK, MODEL SPDE-D-08G-1-DS

ALTERNATE MANUFACTURERS: COOK, CARNES

· MINIMUM AIR FLOW: 210 CFM

· EXT. STATIC PRESSURE: 0.125 IN. WG

· FAN RPM: 1,725

· MOTOR SIZE: 1/30 HP

· VOLTS/PH/HZ: 115/1/60

REQUIRED FEATURES:

· DIRECT-DRIVE

· TEAO MOTOR

· GALVANIZED STEEL FRAME

· ALUMINUM PROPELLER

· GRAVITY OPERATED BACK DRAFT DAMPER, GREENHECK MODEL

WD-320-PB-9x9 OR EQUAL, SHIPPED LOOSE WITH UNIT

· GALVANIZED STEEL WALL HOUSING FOR FLUSH INTERNAL

ATTACHMENT

· INLET OSHA GUARD

· OUTLET INSECT SCREEN

· WALL-MOUNTED LOCKABLE NEMA 3R DISCONNECT, SHIPPED

LOOSE WITH UNIT

· FACTORY CERTIFIED TECHNICIAN STARTUP AND REPORT

· DEMONSTRATION AND TRAINING TO SITE ENGINEER

PUMP HOUSE PASSIVE WALL VENT:

LOUVER, L-1:

BASIS OF DESIGN: GREENHECK, MODEL ESD-403

ALTERNATE MANUFACTURERS: COOK, RUSKIN

· SIZE: 16 IN W x 16 IN H

REQUIRED FEATURES:

· 4 IN DEEP DRAINABLE BLADES

· ALUMINUM CONSTRUCTION

· ALUMINUM INTERNAL INSECT SCREEN

· 12 IN ALUMINUM WALL SLEEVE WITH FLANGES FOR FLUSH

EXTERIOR ATTACHMENT

· OUTLET INSECT SCREEN

DAMPER, D-1:

BASIS OF DESIGN: GREENHECK, MODEL MBD-15

ALTERNATE MANUFACTURERS: COOK, RUSKIN

· SIZE = 16 IN W x 16 IN H

REQUIRED FEATURES:

· GALVANIZED STEEL CONSTRUCTION

· PARALLEL STAMPED BLADES

· LOCKING MANUAL QUADRANT WITH STANDOFF BRACKET

PART 3 - EXECUTION

EXAMINATION

EXAMINE AREAS AND CONDITIONS FOR WORK OF THIS SECTION.

CORRECT CONDITIONS DETRIMENTAL TO PROPER AND TIMELY

COMPLETION OF WORK. DO NOT PROCEED UNTIL UNSATISFACTORY

CONDITIONS HAVE BEEN CORRECTED.

INSTALLATION

PROVIDE ALL MATERIALS AND EQUIPMENT FOR THE WORK. FURNISH AND

INSTALL NECESSARY APPARATUS, PARTS, MATERIALS, AND

ACCESSORIES.

· REFER TO DIVISION 26 FOR ELECTRICAL REQUIREMENTS

DUCTLESS SPLIT-SYSTEM AIR CONDITIONER

INSTALL PER MANUFACTURERS RECOMMENDATIONS AND AS SHOWN ON

THE DRAWINGS.

CONNECTIONS TO INDOOR AND OUTDOOR UNITS WILL BE WITH FLARED

JOINTS WITH COMPRESSION FITTINGS.

TOILET EXHAUST FANS

INSTALL PER MANUFACTURERS RECOMMENDATIONS.

EF-1: CONTROL WITH DIGITAL TIME SWITCH MOUNTED IN SINGLE-GANG

DEVICE BOX MOUNTED ADJACENT TO LIGHT SWITCH.

EF-2A & B, 3A & 3B, 4A & 4B: CONTROL WITH CEILING MOUNTED

COMBINATION PIR/ULTRASONIC OCCUPANCY SENSOR. FAN IS ON WHEN

OCCUPIED AND CYCLES OFF AFTER 15 MINUTES OF NO OCCUPANCY.

PUMP HOUSE PASSIVE WALL VENT

INSTALL PER MANUFACTURERS RECOMMENDATIONS AND AS SHOWN ON

THE DRAWINGS.

8/14/2020

PLUMBING BASIC MATERIALS AND METHODS

PART 1 - GENERAL

SUMMARY

SECTION INCLUDES: BASIC MATERIALS AND METHODS

GENERALLY COMMON TO THE WORK TO PROVIDE COMPLETE,

OPERATIONAL AND FULLY FUNCTIONING DOMESTIC WATER

SYSTEM REPLACEMENTS

SCOPE OF WORK

· CAMPGROUND OFFICE (KIOSK):

o REMOVE ABOVE SLAB SUPPLY, WASTE, AND VENT

PIPING.

o PROVIDE NEW TOILET ROOM FIXTURES, INCLUDING:

TOILET, LAVATORY, AND INSTANTANEOUS UNDER

LAVATORY WATER HEATER.

o PROVIDE CONNECTION TO EXISTING BELOW GRADE

POTABLE WATER AND SEWER AND NEW ABOVE GRADE

PIPING FOR THE INSTALLED FIXTURES.

· COMFORT STATIONS #1, #2, AND #3 (530, 605, AND 607):

o REPLACE EXISTING ABOVE GRADE WASTE AND VENT

PIPING WITH NEW PVC PIPE AND FITTINGS.

o REPLACE EXISTING ABOVE GRADE POTABLE WATER

PIPING WITH NEW POLYPROPYLENE RANDOM

COPOLYMER PIPE WITH FUSED JOINTS.

o REPLACE RIM-WASH SERVICE SINK WITH

FREESTANDING POLYETHYLENE SINK WITH

GOOSENECK METERING FAUCET

o REPLACE ALL TOILET FLUSH VALVES.

· COMFORT STATION #4 (606):

o REPLACE EXISTING ABOVE GRADE WASTE AND VENT

PIPING WITH NEW PVC DWV PIPE AND FITTINGS.

o REPLACE EXISTING ABOVE GRADE POTABLE WATER

PIPING WITH NEW POLYPROPYLENE RANDOM

COPOLYMER PIPE WITH FUSED JOINTS.

o REPLACE TWO (2) ABA HEIGHT WATER CLOSETS.

o REPLACE RIM-WASH SERVICE SINK AND FLUSH VALVE

WITH FREESTANDING POLYETHYLENE SINK WITH

GOOSENECK METERING FAUCET.

o REPLACE ONE (1) TOILET FLUSH VALVE.

· PUMP HOUSE

o REMOVE EXISTING COUNTER AND SINK.

o REPLACE EXISTING ABOVE GRADE POTABLE WATER

PIPING WITH NEW POLYPROPYLENE RANDOM

COPOLYMER PIPE WITH FUSED JOINTS.

o INSTALL NEW COMBINATION EYE-WASH SAFETY

SHOWER (PROVIDED BY GOVERNMENT) WITH

CONNECTION TO DCW PIPING.

o INSTALL NEW UTILITY SINK WITH CONNECTIONS TO

DCW AND SANITARY WASTE PIPING.

SUBMITTALS

SUBMITTALS REQUIRED

· COMPLETE TECHNICAL SUBMITTALS ON ALL PRODUCTS

LISTED PER SECTION 01 33 23

· PRESSURE TEST RESULTS OF ALL MODIFIED PIPING

SYSTEMS

· FLUSHING AND DISINFECTION PLAN AND RESULTS

QUALITY ASSURANCE

STANDARDS: COMPLY WITH APPLICABLE NATIONAL, STATE,

AND LOCAL CODES AND STANDARDS: ASTM, ASME, AND

ANSI. FEDERAL SPECIFICATIONS, AWWA, CISPI, NFPA, FM

GLOBAL, AND UL.

QUALIFICATIONS OF MANUFACTURER: PRODUCTS USED IN

THE WORK OF THIS SECTION SHALL BE PRODUCED BY

MANUFACTURERS REGULARLY ENGAGED IN MANUFACTURE

OF SIMILAR ITEMS AND WITH A HISTORY OF SUCCESSFUL

PRODUCTION AS REVIEWED BY THE NPS CO.

FIELD VERIFICATION: PROVIDE FIELD VERIFICATION OF

INSTALLATION REQUIREMENTS TO ACCOMMODATE THE

NEW EQUIPMENT AND SYSTEMS BEING INSTALLED.

PART 2 - PRODUCTS

GENERAL

PROVIDE THE FOLLOWING PRODUCTS AS A COMPLETE

ASSEMBLY WITH REQUIRED ACCESSORIES FOR A COMPLETE

AND FUNCTIONING ENTITY IN COMPLIANCE WITH GOVERNING

CODES AND APPLICABLE STANDARDS AS SPECIFIED,

MANUFACTURER'S INSTRUCTIONS OR AS REQUIRED. OMISSION

OF MINOR DETAILS DOES NOT WAIVE AND/OR OTHERWISE

RELINQUISH COMPLIANCE WITH THE ABOVE REQUIREMENTS.

MATERIALS AND MANUFACTURERS

WATER CLOSET (WC-1):

BASIS OF DESIGN: AMERICAN STANDARD

ALTERNATE MANUFACTURERS: KOHLER, ELJER

TYPE: FLUSH VALVE, FLOOR-MOUNTED, ADA-COMPLIANT

FIXTURE: VITREOUS CHINA, DIRECT-FED SIPHON JET

ACTION, TOP SPUD, ELONGATED BOWL. MODEL: MADERA

16_1/8 INCHES, UNIVERSAL HEIGHT EL, MODEL 2305.100.

TRIM: SLOAN VALVE CO.; ROYAL CONTINENTAL,

MODEL 111 RC, WITH DUAL FLUSH VALVE HANDLE POINTED

TO WIDE SIDE OF STALL ENCLOSURE, 1.6 GALLONS PER

FLUSH.

SEAT: OLSONITE CORP.; MODEL 10_CC_SS, WHITE OPEN

FRONT.

LAVATORY (LV-1)

BASIS OF DESIGN: AMERICAN STANDARD

ALTERNATE MANUFACTURERS: KOHLER, ELJER

TYPE: WALL-HUNG TYPE, ADA-COMPLIANT

FIXTURE: 20 INCHES BY 18 INCHES, VITREOUS CHINA,

FLOOR-MOUNTED CONCEALED ARM CARRIER, THREE-HOLE

PUNCHED ON 4_INCH CENTERS FOR FAUCET. AMERICAN

STANDARD COMPANIES, INC.; LUCERNE, MODEL 0355.012.

FAUCET: AMERICAN STANDARD, MODEL 2175.506.002,

SINGLE-LEVER, 4-INCH CENTERS, CHROME PLATED, WITH

0.5_GPM FLOW AERATOR.

TRIM: 3/8_INCH SUPPLY STOP WITH LOOSE KEY, 17_GAUGE

CHROME-PLATED CAST BRASS P-TRAP.

INSULATION: MCGUIRE MANUFACTURING COMPANY, INC.,

PROWRAP ANTIMICROBIAL PVC RESIN SEAMLESS

INSULATION FOR TRAP, TAILPIECE, AND HOT AND COLD

WATER SUPPLY PIPING.

STRAINER: MCGUIRE MANUFACTURING COMPANY, INC.;

MODEL 155A CHROME-PLATED GRID STRAINER.

TAILPIECE: 20-GAUGE CHROME-PLATED CAST BRASS WITH

BRANCH CONNECTION, PRO-FLO PFPTB300 SERIES OR

EQUAL.

CARRIER: JAY R. SMITH MFG. CO.; 700 SERIES CONCEALED

ARM.

SERVICE SINK (SS-1):

BASIS OF DESIGN: AMERICAN STANDARD

ALTERNATE MANUFACTURERS: MUSTEE, KOHLER

TYPE: FREESTANDING

FIXTURE: SINGLE 20 INCH BY 23.875 INCH BOWL, HEAVY

DUTY POLYETHELENE, PAINTED STEEL LEGS, TWO-HOLE

PUNCHED ON 4-INCH CENTERS FOR FAUCET. AMERICAN

STANDARD COMPANIES, INC.; FIAT, MODEL TAT1100.

FAUCET: AMERICAN STANDARD, MODEL 7500.170.002,

DUAL-LEVER, BLADE HANDLES, 4-INCH CENTERS, CHROME

PLATED, GOOSENECK SWIVEL SPOUT, AERATOR.

TRIM: 3/8-INCH SUPPLY STOP WITH LOOSE KEY.

HARDWARE: FIAT DRAIN ASSEMBLY TAT1 PA-11. HARDWARE

KITS 02883906000 AND 02883900100.

SERVICE SINK (SS-2):

BASIS OF DESIGN: AMERICAN STANDARD

ALTERNATE MANUFACTURERS: MUSTEE, KOHLER

TYPE: FREESTANDING

FIXTURE: SINGLE 20 INCH BY 23.875 INCH BOWL, HEAVY

DUTY POLYETHELENE, PAINTED STEEL LEGS, TWO-HOLE

PUNCHED ON 4-INCH CENTERS FOR FAUCET. AMERICAN

STANDARD COMPANIES, INC.; FIAT, MODEL TAT1100.

FAUCET: T&S BRASS, MODEL B-0834-01, DUAL-LEVER,

BLADE HANDLES, 4-INCH CENTERS, METERING CARTRIDGES,

CHROME PLATED, GOOSENECK SWIVEL SPOUT, AERATOR.

TRIM: 3/8-INCH SUPPLY STOP WITH LOOSE KEY.

HARDWARE: FIAT DRAIN ASSEMBLY TAT1 PA-11. HARDWARE

KITS 02883906000 AND 02883900100.

ELECTRIC WATER HEATER (EWH-1):

BASIS OF DESIGN: EEMAX, MODEL EX-3012-SL

ALTERNATE MANUFACTURERS: CHRONOMITE, BOSCH.

TYPE: SINGLE-FIXTURE, WALL MOUNT, UNDER SINK

MOUNTING SUITABLE FOR ADA LAVATORY

FIXTURE: ABS-UL 94V0 RATED COVER, REPLACEABLE

CARTRIDGE INSERT, REPLACEABLE INLET FILTER,

IRON-FREE NICKEL-CHROME ELEMENT, 150 PSIG MAX

OPERATING PRESSURE,

TRIM: COMPRESSION FITTINGS

RATING: 3.0 KW, 0.5 GPM, 41 °F RISE

ELECTRICAL: 120 VAC/60/1, 25 AMP

DOMESTIC WATER BALL VALVES: WATTS MODEL BV, LOW

LEAD TYPE, NIBCO OR EQUAL.

EYEWASH/SAFETY SHOWER: GUARDIAN MODEL G1902,

PROVIDE BY GOVERNMENT.

WALL HYDRANT (WH-1): NON-FREEZE BOX TYPE WITH

CHROME PLATED FACE, INTEGRAL VACUUM BREAKER,

BRONZE CASING, T-HANDLE KEY, 3/4-INCH INLET AND HOST

CONNECTION. JR SMITH, FIGURE 5509, JOSAM 71000

SERIES, OR EQUAL.

PIPING - GENERAL: PIPING SHALL BE CONTINUOUSLY AND

PERMANENTLY MARKED WITH MANUFACTURER'S NAME,

TYPE OF MATERIAL, SIZE, PRESSURE RATING, AND THE

APPLICABLE ASTM, ANSI, UL, OR NSF LISTING. ON PLASTIC

PIPE, DATE OF EXTRUSION MUST ALSO BE MARKED.

PIPING - DOMESTIC HOT AND COLD WATER: AQUATHERM®

SDR 7.4 PRESSURE RATED POLYPROYLENE (PP) PER ASTM F

2389-06 AND NSF CERTIFIED FOR POTABLE WATER, PIPE

AND FITTINGS. FITTINGS: SOCKET-FUSION, ELECRO-FUSION,

OR BUTT-FUSION AS MANUFACTURED BY AQUATHERM®.

PIPING - WASTE AND VENT: PVC DRAIN, WASTE AND VENT

PIPING AND FITTINGS, PER ASTM D 2665, SOLID WALL, WITH

PVC SOCKET TYPE FITTINGS, SOLVENT CEMENT AND

ADHESIVE PRIMER JOINTS.

PIPE HANGERS AND SUPPORTS: HANGERS, INSERTS, AND

SUPPORTS CONFORM TO MSS SP-58 AND AS

RECOMMENDED BY PIPING SYSTEM MANUFACTURERS.

PIPE INSULATION - ABOVE AMBIENT: ARMACELL

AP/ARMAFLEX, OR EQUAL. THICKNESS TO COMPLY WITH

CEC REQUIREMENTS OR CONDENSATION CONTROL

THICKNESS, WHICHEVER IS GREATER.

PIPE INSULATION - BELOW AMBIENT: ARMACELL

AP/ARMAFLEX, OR EQUAL. THICKNESS TO COMPLY WITH

CEC REQUIREMENTS OR CONDENSATION CONTROL

THICKNESS, WHICHEVER IS GREATER.

PART 3 - EXECUTION

EXAMINATION

EXAMINE AREAS AND CONDITIONS UNDER WHICH WORK OF THIS

SECTION SHALL BE PERFORMED. CORRECT CONDITIONS

DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF WORK.

DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE

BEEN CORRECTED.

INSTALLATION

PROVIDE ALL MATERIALS AND EQUIPMENT FOR THE WORK.

FURNISH AND INSTALL NECESSARY APPARATUS, PARTS,

MATERIALS, AND ACCESSORIES FOR A COMPLETE OPERATIONAL

PLUMBING SYSTEM.

PIPE INSTALLATION:

INSTALL PIPING PARALLEL TO WALL AND PROVIDE AN ORDERLY

GROUPING OF PROPER MATERIALS AND EXECUTION.

INSULATE ALL PIPING CONCEALED IN WALL CAVITIES PER SPECS

ABOVE.

ANCHOR PIPING SUBJECT TO EXPANSION OR CONTRACTION IN A

MANNER WHICH PERMITS STRAINS TO BE EVENLY DISTRIBUTED.

INSTALL SWING JOINTS OR EXPANSION LOOPS WHEN REQUIRED.

INSTALL PROPRIETARY PIPING SYSTEMS AND FITTINGS IN

STRICT ACCORDANCE WITH THE MANUFACTURERS WRITTEN

INSTRUCTIONS.

DOMESTIC WATER SUPPLY PIPING:

· FLUSH SYSTEMS CLEAN OF INTERNAL DEBRIS

· DISINFECT PER CODE REQUIREMENTS PER AWWA C651

· PRESSURE TEST FOR LEAKAGE BEFORE COVER 1.5 TIMES

SYSTEM PRESSURE

· CLEAN FAUCET AERATORS

· ADJUST FIXTURE VALVES FOR MANUFACTURER'S

RECOMMENDED FLOW

· PROVIDE MINIMUM 2 FEET OF COVER ON EXTERIOR WATER

PIPING OR INSTALL BELOW FROST LINE, WHICHEVER IS

GREATER.

SANITARY WASTE AND VENT PIPING:

· SET PIPING ABOVE FLOOR SLAB TRUE AND PLUMB

· SLOPE DRAIN LINES AT 2 PERCENT MINIMUM SLOPE

· INSTALL VENT LINES LEVEL OR SLOPED WITHOUT LOW

SPOTS

· INSTALL ROOF FLASHING SLEEVE SECURED TO ROOF

· EXTEND VENT MINIMUM 1 FOOT ABOVE ROOF

· PROVIDE CLEANOUTS WHERE SHOWN OR REQUIRED BY

CODE

· PROVIDE WATER TESTS PER LOCAL CODE REQUIREMENTS

HANGERS AND SUPPORTS:

CONFORM TO MANUFACTURER'S STANDARDIZATION

SOCIETY SPECIFICATION SP-69 WITH ROD SIZE AND

SPACING PER THE CMC.

HORIZONTAL PIPING: PROTECT PIPE INSULATION WITH

INSULATION SHIELD SUITABLE FOR PIPE SIZE AND

INSULATION. HANGERS, CLAMPS, AND GUIDES FURNISHED

FOR SUPPORT OF NON-METALLIC PIPE SHALL BE

SEPARATED WITH 1/8-INCH-THICK RUBBER OR NEOPRENE.

ELECTRICAL

· REFER TO DIVISION 26 FOR ELECTRICAL REQUIREMENTS

WC-1

LV-1

4" SAN UP

TO WC

4" UG SAN

1 1/4" AG SAN

EXTEND TO EXISTING

SAN OR MANHOLE

EXTEND TO EXISTING DCW

SUPPLY - SEE CIVIL FOR

EXISTING SUPPLY AND

DRAIN DOWN VALVE BOXES

1 1/4" DCW

1 1/4" CW UP TO BUILDING VALVE

WATER SUPPLY AND DISTRIBUTION TO BE

INSTALLED WITH MANUAL AIR VENT AT

HIGHEST POINT TO ALLOW COMPLETE DRAIN

DOWN OF SYSTEM FOR WINTER.

CUT AND PATCH CONCRETE

FLOOR AS REQUIRED FOR BELOW

SLAB SAN INSTALLATION.

ALL EXISTING FIXTURES PREVIOUSLY

REMOVED. DEMO ALL EXISTING DCW

SUPPLY AND SAN WASTE AND VENT ABOVE

SLAB. CAP, CONCEAL, AND ABANDON

BELOW SLAB. PATCH SLAB AS REQUIRED.

REMOVE EXISTING WALL

HYDRANT. INSTALL NEW WH-1 IN

EXISTING HOLE. SELECT FOR 8"

WALL THICKNESS. TURN DOWN

WITH ELBOW ON INTERIOR SIDE

OF WALL INSULATION.

EWH-1 INSTALLED AT

12" ABOVE FLOOR.

GCO

3" VTR

1 1/4" DCW

1/2" LAVATORY SUPPLY STOP

T

3/4" PVC CONDENSATE DRAIN ROUTED BELOW

REFRIGERANT PIPING, THROUGH WALL, AND DOWN

TO GRADE. PROVIDE PRE-CAST CONCRETE

SPLASHBLOCK AT DISCHARGE.

ROUTE REFRIGERANT PIPING

THROUGH WALL AND DOWN TO

CONNECT TO HP-1B AS SHOWN.

COVER WITH INTERIOR/EXTERIOR

PIPING COVER KIT PROVIDED WITH

UNIT.

DUCTLESS HEAT PUMP OUTDOOR

UNIT HP-1B ON 12" HIGH STAND

PROVIDED WITH UNIT AND MIN 4"

THICK CAST-IN-PLACE CONCRETE

PAD.

8"Ø SEMI-RIGID FLEX DUCT ATTACHED

TO FAN AND HOOD COLLARS WITH 8"Ø

WORM GEAR DUCT CLAMPS.

DUCTLESS HEAT PUMP INDOOR

UNIT HP-1A MOUNTED TO WALL

WITH BOTTOM AT 96" ABOVE

FLOOR AND CENTERED ABOVE

WINDOW.

WIRELESS REMOTE CONTROL

THERMOSTAT AND HOLDER

MOUNTED TO WALL AT 48"

ABOVE FLOOR.

WALL MOUNTED EXHAUST FAN EF-1.

INSTALL WITH BOTTOM OF INLET

GRILLE AT 72" ABOVE FLOOR.

EXTERIOR WALL CAP. CAULK SEAL

AROUND CAP FACEPLATE

WEATHERTIGHT.

REMOVE ALL AG DCW SUPPLY FROM WELL PUMP DISCHARGE TO

SLAB PENETRATION. REMOVE EXISTING COUNTER AND DROP-IN

SERVICE SINK AND ASSOCIATED PIPING. INSTALL APPROX. 25 LF

OF NEW 1-1/2" PVC MAIN AG DCW SUPPLY LINE.

REMOVE EXISTING WALL DAMPER

AND SLEEVE. INSTALL NEW LOUVER

L-1, SLEEVE, MANUAL DAMPER D-1,

AND INSECT SCREEN. ENLARGE OR

INFILL OPENING AS NEEDED TO

ACCOMMODATE NEW SLEEVE.

INSTALL NEW COMBINATION SAFETY SHOWER/EYE

WASH STATION (GUARDIAN MODEL G1902)

PROVIDED BY GOVERNMENT. INCLUDE 1-1/4" DCW

SUPPLY AND MANUAL SHUTOFF BALL VALVE.

1-1/4" P-TRAP FROM SINK TO 2"

WASTE/VENT RISER IN WALL. 2" UG

SAN TO DIRECT CONNECTION AT

EXISTING UNDERSLAB DRAIN AS

SHOWN. SAWCUT AND PATCH SLAB

AS REQUIRED.

SS-1

1-1/2" DCW CONNECTED TO NEW AG

DCW MAIN WITH SHUT-OFF VALVE IN

VERTICAL AND ROUTED ALONG WALL

TO NEW FIXTURES AS SHOWN.

2" VTR IN

NEW WALL

1/2" SERVICE

SINK SUPPLY

STOP

NEW AG

DCW MAIN

KIOSK - HVAC

SCALE: 1/4" = 1'-0"

KIOSK - PLUMBING

SCALE: 1/4" = 1'-0"

PUMP HOUSE

SCALE: 1/4" = 1'-0"

REPLACE ALL ABOVE GRADE WATER,

WASTE, AND VENT PIPING (TOTAL OF

APPROX. 80 LF OF PVC PIPE) IN CHASE.

NEW EXHAUST FAN

EF-2A (EF-3A FOR

COMFORT STATION

#3) . INSTALLATION

IDENTICAL TO EF-2B

(EF-3B FOR COMFORT

STATION #3).

WOOD FRAME 12"x12" OPENING IN

EXISTING LOUVER OPENING TO

ACCOMMODATE NEW EXHAUST FAN.

POSITION IN EXISTING LOUVER

OPENING TO ACCOMMODATE

EXISTING ROOF STRUCTURE.

NEW WALL MOUNTED EXHAUST FAN

EF-2B (EF-3B FOR COMFORT STATION

#3) WITH FAN HOUSING AND

BACKDRAFT DAMPER.

BLANK OFF REMAINING LOUVER

OPENING AT INTERIOR WITH 18 GA 304

STAINLESS STEEL SHEET METAL WITH

SST SCREWS. PAINT BOTH SIDES OF

BLANK-OFF PANELS TO MATCH

EXISTING FRAMING AND CEILING.

EXISTING BRICK VENTS TO BE

REPLACED. SEE ARCHITECTURAL

DRAWINGS. (TYPICAL 4)

REPLACE ALL WC FLUSH

VALVES. (TYPICAL 5)

SS-2

REMOVE EXISTING RIM-WASH UTILITY

SINK. CONNECT NEW SINK TO NEW DCW

SUPPLY AND AG SAN WASTE PIPING

REPLACE ALL ABOVE GRADE WATER,

WASTE, AND VENT PIPING (TOTAL OF

APPROX. 80 LF OF PVC PIPE) IN CHASE.

NEW EXHAUST FAN

EF-4A. INSTALLATION

IDENTICAL TO EF-4B.

WOOD FRAME 12"x12" OPENING IN

EXISTING LOUVER OPENING TO

ACCOMMODATE NEW EXHAUST FAN.

POSITION IN EXISTING LOUVER

OPENING TO ACCOMMODATE

EXISTING ROOF STRUCTURE.

NEW WALL MOUNTED EXHAUST FAN

EF-4B WITH FAN HOUSING AND

BACKDRAFT DAMPER.

BLANK OFF REMAINING LOUVER

OPENING AT INTERIOR WITH 18 GA 304

STAINLESS STEEL SHEET METAL WITH

SST SCREWS. PAINT BOTH SIDES OF

BLANK-OFF PANELS TO MATCH

EXISTING FRAMING AND CEILING.

EXISTING BRICK VENTS TO BE

REPLACED. SEE ARCHITECTURAL

DRAWINGS. (TYPICAL 4)

REPLACE THIS

WC FLUSH

VALVE ONLY.

WC-1

WC-1

SS-2

REMOVE EXISTING RIM-WASH UTILITY

SINK. CONNECT NEW SINK TO NEW DCW

SUPPLY AND AG SAN WASTE PIPING

REPLACE ALL ABOVE GRADE WATER,

WASTE, AND VENT PIPING (TOTAL OF

APPROX. 80 LF OF PVC PIPE) IN CHASE.

EXISTING BRICK VENTS TO BE

REPLACED. SEE ARCHITECTURAL

DRAWINGS. (TYPICAL 4)

REPLACE ALL WC FLUSH

VALVES. (TYPICAL 5)

SS-2

REMOVE EXISTING RIM-WASH UTILITY

SINK. CONNECT NEW SINK TO NEW DCW

SUPPLY AND AG SAN WASTE PIPING

COMFORT STATION #1 - 530

SCALE: 1/4" = 1'-0"

COMFORT STATION #2 - 605 (AND #3 - 607)

SCALE: 1/4" = 1'-0"

COMFORT STATION #4 - 606

SCALE: 1/4" = 1'-0"

G

SYMBOL DESCRIPTIONSYMBOL DESCRIPTION

ELECTRICAL LEGEND

DESCRIPTIONSYMBOL

S

S

SYMBOL DESCRIPTION

SS

SS

S

DB

M

E-OVH

OR

E-BUR

P

ES

x

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

DUMPSTERPAD

DISK

1984 PG46-E

ROCK

OUTCROPPING

ROCK

OUTCROPPING

UTILITY

STATION

W

W

W

W

W

W

W

W

DUMPSTERPAD

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

W

EXISTING SEWER LINE FROM

KIOSK BUILDING TO EXISTING

DRAINFIELD AT MAINTENANCE

BUILDING

P

P

E

S x

E

O

V

H

P

P

P

P

P

E

O

V

H

E

O

V

H

E

O

V

H

P

P

P

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

W

W

W

W

W

W

W

W

W

W

W W W W W W W W W

W W W W W W W W W

ROCK

OUTCROPPING

ROCK

OUTCROPPING

W

W

WW

W

W

W

W W W

W

W

W

W W

W

WW

W

W

W

W W

W

W

W W

W W W

W

W

W

WW

WW

WW

W

W

W W

W W

W W W

W

W

WW

WWWW

W

WW

W

W W

W

WW

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W W

W W

W W w w w w w w

X

X

W

WW

W

W

WW

W

W

WW

W

W

WW

W

W

WW

W

W

WW

W

W

WW

W

W

W

WW

W

W

WW

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W

WM

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

E-BUR

E-BU

R

E-BUR

E-BUR

E-BU

R

E-BUR

E-BU

R

E-BUR

E-BUR

E-BU

R

E-BUR

E-BU

R

E-BUR

E-BUR

E-BU

R

E-BUR

E-BU

R

E-BUR

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-OVH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-OVH

E-O

VH

E-O

VH

E-OVH

E-OV

H

E-O

VH

E-O

VH

E-O

VH

E-OV

H

E-O

VH

E-O

VH

E-OVH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-OVH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-O

VH

E-OVH

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OV

H

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-OV

H

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-OV

H

E-OVH

E-OVH

E-OVH

E-OVH

E-OV

H

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

E-O

VH

E-O

VH

E-O

VH

E-OVH

E-OVH

E-OVH

E-OVH

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

T

T

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

T

E-BUR

E-BU

R

E-BU

R

E-B

UR

E-BU

R

E-BUR

E-BUR

E-BUR

E-BU

R

E-BU

R

E-BUR

E-BU

R

E-BU

R

E-BU

R

E-BU

R

E-BU

R

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR E-BUR E-BUR

E-BUR

E-BUR

R

V

RV

RV

RV

RV

RV

R

V

R

V

RV

RV

R

V

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

E-OVH

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

T

E-B

UR

DB

DB

DB

DB

DB

DB

DBDB

DBDB

DBDBDB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DBDB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDB

DB

DB

DB

DB

DB

DB

DB

E-BU

R

E-BU

R

E-BU

R

E-BU

R

E-BU

R

E-BUR

E-BUR

E-BUR

E-BUR

E-BU

R

E-BUR E-BUR E-BUR

E-BUR

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

DB

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BURE-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BU

R

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

E-BUR

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

WM

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W W W W W W W W W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

T

T

LA LA

LA

N

N

EQUIPMENT NAMEPLATE REQUIREMENTS

NTS

OSHA/NEC PLACARD

NTS

CONDUIT EXPANSION JOINT

NTS

CAVITY ELECTRICAL OUTLET BOX

NTS

FIRE RATED DRYWALL STUD

GROUND ROD

NTS

PIPE CLAMP BONDING

NTS

CONDUIT GROUNDING

NTS

CONDUIT SUPPORT ON STRUCTURE

NTS

4"

1/2"

SIDEFRONT

TOP

FLEXIBLE CONDUIT SUPPORT

NTS

ELECTRICAL EQUIPMENT SUPPORT

NTS

TYPICAL UNDERGROUND CONDUIT

NTS

HAND HOLE

NTS

8 97

2 31

5 64

CONCRETE ENCASED DUCTBANK

NTS

SheetMark REVISION Date Initial

E O

V H

P

P

P

P

P

P

E-BUR

RV

RV

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

W

M

W

M

W

M

W

M

W

M

W

M

W

M

D

I

S

K

E

P

P

E

O

V

H

E

O

V

H

E

O

V

H

E

O

V

H

E

O

V

H

E

O

V

H

E

O

V

H

E

O

V

H

File details come from the government source that posted it. Updated .