B08_Attach_0003_Price_Schedule_140P5125Q0002.xls
XLS spreadsheet 25 KB Posted
- Attached to
- Equipment Replacement - Boiler Unit Federal contract opportunity
- Solicitation number
- 140P5125Q0002
About this file
This is a pricing schedule template for solicitation 140P5125Q0002 issued by the Department of Interior National Park Service Southeast Region for boiler replacement work at Kennesaw Mountain National Battlefield Park Visitor Center.
The scope includes removing and disposing of an existing 500k BTU boiler and installing a new energy-efficient, Low NOx outdoor-rated boiler with necessary plumbing, piping, and electrical upgrades. The contractor must provide commercial industrial warranty, install a new thermostat with temperature/humidity reading, perform system testing and balancing, dispose of equipment properly, repair/replace connecting ductwork and piping as needed, and coordinate utility interruptions with 24-hour notice. The template requires breakdown of costs for labor, equipment, travel, overhead, profit, and bonding. The contractor must also provide training on operation, maintenance, and troubleshooting, as well as conduct startup testing. The form requires the contractor's signature, CAGE code, and Unique Entity Identifier (UEI).
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A04_Attachmennt_0010_RSOW_140P5125Q0002_0001.pdf | ||
| B08_Attach_0010_Revsied_Price_Schedule_140P5125Q0002_0001.xls | XLS spreadsheet | |
| Sol_140P5125Q0002_Amd_0001.pdf | ||
| Amend_0001_Questions_and_Answers_0001.docx | DOCX document | |
| A04_Attachment_0001_SOW_0044004365_.pdf | ||
| B08_Attach_0004_Site_Visit_Information_140P5125Q0002.pdf | ||
| B03_Attachment__0002_WDOL_WD_140P5125Q0002.pdf | ||
| B08_Attach_0007_SF1413-23_140P5125Q0002.pdf | ||
| Sol_140P5125Q0002.pdf | ||
| Construction_Contract_Administration.docx | DOCX document | |
| B08_Attach_0005_Past_Performance_Questionnaire_140P5125Q0002.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Price Quote
| SOLICITATION PRICE SCHEDULE | |||||
| SOLICITATION NUMBER: 140P5125Q0002 | |||||
| PROJECT TITLE: Equipment Replacement - Boiler Unit Replacement Kennesaw Mountain National Battlefield Park Visitor Center | |||||
| CONTRACT LINE ITEM NUMBER (CLIN) | CONTRACT LINE ITEM (CLI) TITLE | QUANTITY | UNIT OF MEASURE | UNIT PRICE | TOTAL PRICE |
| 00010 | This project shall remove and dispose of the existing 500k btu boiler and install a same or equivalent outdoor rated boiler and necessary plumbing at the Visitor Center. The Contractor shall install an Energy Efficient, Low NOx boiler unit, piping, and electrical upgrades where necessary. The unit must come with a commercial industrial standard warranty. Install new thermostat with temperature and humidity reading. Perform test and balance for systems with new equipment. Safely dispose of all equipment to a reputable landfill or recycling center. Repair or replace all existing ductwork, and other line sets and piping at the connecting points with the new equipment, if needed. Coordinate all work and utility service interruptions with park staff. No less than a 24-hour notice shall be given before any type of utility interruption is to occur. Interruptions shall not exceed more than one working day. All affected areas must be restored to their original condition from before the work began. Any damages will be fixed and repaired at no cost to the government. Clean jobsite of all dust and debris at the end of each workday and ensure that all work is performed in a professional manner. All testing and compliance will be done before completion. The installer will provide training for safe operation, preventive maintenance, and troubleshooting of the unit, a startup test shall be done for proper operation at Kennesaw Mountain National Battlefield Park Kennesaw, Georgia per the attached statement of work. | 1 | LS | ||
| TOTAL PROPOSED PRICE | $0.00 | ||||
| Authorized Signature: __________________________________________________ Date: __________________________ | |||||
| Offerors Cage Code: ______________ | |||||
| Offerors Unique Entity Number (UEI): ________________________ |
&RPARK - PMIS
CPS - &P
Cost Breakdown
| SOLICITATION PRICE SCHEDULE | ||||||||
| SOLICITATION NUMBER: 140P5125Q0002 | ||||||||
| PROJECT TITLE: Equipment Replacement - Boiler Unit Replacement Kennesaw Mountain National Battlefield Park Visitor Center | ||||||||
| CONTRACT LINE ITEM NUMBER (CLIN) | CONTRACT LINE ITEM (CLI) TITLE | Labor | Equipment | Travel | Overhead | Profit | Bonding | TOTAL PRICE |
| 00010 | This project shall remove and dispose of the existing 500k btu boiler and install a same or equivalent outdoor rated boiler and necessary plumbing at the Visitor Center. The Contractor shall install an Energy Efficient boiler unit, piping, and electrical upgrades where necessary. The unit must come with a commercial industrial standard warranty. All testing and compliance will be done before completion. The installer will provide training for safe operation, preventive maintenance, and troubleshooting of the unit, a startup test shall be done for proper operation at Kennesaw Mountain National Battlefield Park Kennesaw, Georgia per the attached statement of work. | |||||||
| TOTAL PROPOSED PRICE | $0.00 |
File details come from the government source that posted it. Updated .