B08_Attach_0010_Revsied_Price_Schedule_140P5125Q0002_0001.xls

XLS spreadsheet 26 KB Posted

Attached to
Equipment Replacement - Boiler Unit
Solicitation number
140P5125Q0002
Issued by

About this file

This is a pricing schedule template for solicitation 140P5125Q0002 issued by the Department of the Interior National Park Service Southeast Region for boiler unit replacement at the Kennesaw Mountain National Battlefield Park Visitor Center.

The schedule contains two CLINs: CLIN 00010 requires removal and disposal of an existing 500k BTU boiler and installation of an equivalent outdoor-rated, energy-efficient, Low NOx boiler with necessary plumbing, piping, and electrical upgrades. The work includes installing a new thermostat with temperature/humidity reading, performing system testing and balancing, coordinating utility interruptions with 24-hour notice, and providing training for operation and maintenance. CLIN 00020 is an additive item for thermostat installation requiring COR approval. The template includes spaces for unit pricing, labor, equipment, travel, overhead, profit, and bonding costs, as well as fields for contractor signature, CAGE code, and UEI number.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Price Quote

SOLICITATION PRICE SCHEDULE
SOLICITATION NUMBER: 140P5125Q0002
PROJECT TITLE: Equipment Replacement - Boiler Unit Replacement Kennesaw Mountain National Battlefield Park Visitor Center
CONTRACT LINE ITEM NUMBER (CLIN)CONTRACT LINE ITEM (CLI) TITLEQUANTITYUNIT OF MEASUREUNIT PRICETOTAL PRICE
00010This project shall remove and dispose of the existing 500k btu boiler and install a same or equivalent outdoor rated boiler and necessary plumbing at the Visitor Center. The Contractor shall install an Energy Efficient, Low NOx boiler unit, piping, and electrical upgrades where necessary. The unit must come with a commercial industrial standard warranty. Install new thermostat with temperature and humidity reading. Perform test and balance for systems with new equipment. Safely dispose of all equipment to a reputable landfill or recycling center. Repair or replace all existing ductwork, and other line sets and piping at the connecting points with the new equipment, if needed. Coordinate all work and utility service interruptions with park staff. No less than a 24-hour notice shall be given before any type of utility interruption is to occur. Interruptions shall not exceed more than one working day. All affected areas must be restored to their original condition from before the work began. Any damages will be fixed and repaired at no cost to the government. Clean jobsite of all dust and debris at the end of each workday and ensure that all work is performed in a professional manner. All testing and compliance will be done before completion. The installer will provide training for safe operation, preventive maintenance, and troubleshooting of the unit, a startup test shall be done for proper operation at Kennesaw Mountain National Battlefield Park Kennesaw, Georgia per the attached statement of work.1LS
00020Additive: Install thermostat (Must be approved by the COR prior to installation).1LS
TOTAL PROPOSED PRICE$0.00
Authorized Signature: __________________________________________________ Date: __________________________
Offerors Cage Code: ______________
Offerors Unique Entity Number (UEI): ________________________

&RPARK - PMIS

CPS - &P

Cost Breakdown

SOLICITATION PRICE SCHEDULE
SOLICITATION NUMBER: 140P5125Q0002
PROJECT TITLE: Equipment Replacement - Boiler Unit Replacement Kennesaw Mountain National Battlefield Park Visitor Center
CONTRACT LINE ITEM NUMBER (CLIN)CONTRACT LINE ITEM (CLI) TITLELaborEquipmentTravelOverheadProfitBondingTOTAL PRICE
00010This project shall remove and dispose of the existing 500k btu boiler and install a same or equivalent outdoor rated boiler and necessary plumbing at the Visitor Center. The Contractor shall install an Energy Efficient boiler unit, piping, and electrical upgrades where necessary. The unit must come with a commercial industrial standard warranty. All testing and compliance will be done before completion. The installer will provide training for safe operation, preventive maintenance, and troubleshooting of the unit, a startup test shall be done for proper operation at Kennesaw Mountain National Battlefield Park Kennesaw, Georgia per the attached statement of work.
TOTAL PROPOSED PRICE$0.00

File details come from the government source that posted it. Updated .