B.08.02.07.09 MPMG SOW Section 011010_Att 9_MPMG Narrative Description Mar2017.pdf

PDF 584 KB Posted

Attached to
Range Improvements, Slunj, Croatia
Solicitation number
W912GB21R0018
Issued by

About this file

This document outlines requirements for a federal construction contract opportunity with the U.S. Army Corps of Engineers Europe District. The contract involves three range improvement projects at the 7th ATC in Slunj, Croatia, including converting an existing tank range to a multipurpose machine gun range, converting a structure to a live fire shoot house, and constructing an unreinforced concrete rapid runway repair pad. The multipurpose machine gun range project will require earthwork, construction of firing emplacements for ground and vehicle weapons, and installation of target emplacements. The live fire shoot house project will convert an existing structure through structural and architectural work. The rapid runway repair project focuses on site preparation and placement of the concrete pad. Interested vendors can attend an in-person site visit or pre-register for a virtual pre-proposal conference in advance of the site visit. The solicitation number is W912GB21R0018 and is being conducted by the Department of the Army European Command.

View the file

Other files

File Type Posted
B.08.03 Amendment 0003 W912GB21R0018.pdf PDF
B.08.02.07 MPMG SOW Section 011010 - Amended 2021.06.17.pdf PDF
B.08.02.09.02 LFSH SOW Section 011010_Att2_Concept Drawings - Amended 2021.06.17.pdf PDF
B.08.02.07 MPMG SOW Section 011010 - Amended 2021.06.17.pdf PDF
B.08.02.09 LFSH SOW Section 011010 - Amended 2021.06.17.pdf PDF
B.08.03 Amendment 0002 RFP W912GB21R0018.pdf PDF
B.07.01 2021.06.11 - W912GB21R0018 PPC Slides.pdf PDF
B.08.03 Amendment 0001 RFP W912GB21R0018.pdf PDF
B.07.01 7ATC Range Improvements, Slunj, Croatia Site, Visit Roster - 2021.06.08.pdf PDF
B.08.02.09.03 LFSH SOW Section 011010_Att3_Structural Calculations.pdf PDF
B.08.02.07.03 MPMG SOW Section 011010_Att 3_Structural Calculations.pdf PDF
B.08.02.09.06 LFSH SOW Section 011010_Att6_UFC 04 179 02_Small Arms Range.pdf PDF
B.08.02.07.04 MPMG SOW Section 011010_Att 4_MPMG Description.pdf PDF
B.08.02.09.04 LFSH SOW Section 011010_Att4_10 48 60_Ballistic Specifications.pdf PDF
B.08.02.07.02 MPMG SOW Section 011010_Att 2_Concept Site Plan.pdf PDF
B.08.02.09.07 LFSH SOW Section 011010_Att7_Shoothouse Standard Design Guide.pdf PDF
B.08.02.07.08 MPMG SOW Section 011010_Att 8_MAT Detail.pdf PDF
B.08.02.07.01 MPMG SOW Section 011010_Att 1_Location Map.pdf PDF
B.08.02.07.10 MPMG SOW Section 011010_Att 10_TC 25-8.pdf PDF
B.08.02.04 Attachment 4_BLA Template.docx DOCX document
B.08.02.09.01 LFSH SOW Section 011010_Att1_Location Map.pdf PDF
B.08.02.09.02 LFSH SOW Section 011010_Att2_Conceptual Drawings.pdf PDF
B.08.02.07 MPMG SOW Section 011010.pdf PDF
B.08.02.06 Specifications Binder Slunj Rg Imprv 2021.05.04.pdf PDF
B.08.02.08.02 RRR SOW Section 011010_Att2_Conceptual Plan.pdf PDF
B.08.02.10 RFP Attch Site Visit Registration Form v2.xlsx XLSX spreadsheet
B.08.02.09 LFSH SOW Section 011010_011010.pdf PDF
B.08.02.01 Attachment 1_Past Performance Info Sheet.pdf PDF
B.08.02.09.05 LFSH SOW Section 011010_Att5_05 12 00_Metals.pdf PDF
B.08.02.03 Attachment 3_Letter of Commitment Sample.docx DOCX document
B.08.02.07.07 MPMG SOW Section 011010_Att 7_SAT Detail.pdf PDF
B.08.02.07.05 MPMG SOW Section 011010_Att 5_Firing Position.pdf PDF
B.08.02.08 RRR SOW Section 011010.pdf PDF
B.08.02.02 Attachment 2_PPQ.pdf PDF
B.08.02.07.06 MPMG SOW Section 011010_Att 6_SIT.pdf PDF
B.08.02 RFP W912GB21R0018 Range Improvements, Slunj, Croatia.pdf PDF
B.08.02.08.01 RRR SOW Section 011010_Att1_Location Map.pdf PDF
B.08.02.05 Attachment 5_BLG Template.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RANGE AND TRAINING LAND PROGRAM – MANDATORY CENTER OF EXPERTISE

U.S. ARMY ENGINEERING AND SUPPORT CENTER, HUNTSVILLE

HUNTSVILLE, ALABAMA

256-895-1534

EMAIL RTLP

RANGE DESIGN GUIDE

17833

Multipurpose Machine Gun (MPMG) mailto:DLL-CEHNC-RTLP@usace.army.mil

BUILDING STRONG®

M u lt ip u rp o s e

M a c h in e

G u n R a n g e

M

P M

G

M a rc h

R T L P

-M C

X R a n g e

D e s ig n G u id e

General

This document contains information specific to a Multipurpose Machine Gun Range (MPMG), FCC 17833. The document includes references to other sections of the RDG for information that is general to multiple range types. The document describes the design and construction information that is specific to the range and is not contained in, or differs from, the general section. Use both the specific information in this section and the general sections referenced together for a complete, useable range.

Purpose

The Multipurpose Machine Gun (MPMG) range is used to train and test soldiers on the skills necessary to zero, detect, identify, engage and defeat stationary and moving infantry and armor targets in a tactical array. The range supports both light and heavy machine guns in both vehicle mounted and ground based configurations. The standard MPMG includes the Sniper Field Fire

(SFF), FCC 17812, as an overlay and supports all sniper weapons in both known and unknown distance training.

Primary Features

This section provides the standard layout and a listing of the primary features that are standard on an MPMG; separated between Down Range and Range Operations and Control Area

(ROCA). The tables include the number and/or size of each item included in a standard facility with hyperlinks to the RDG section with the general design and construction requirements.

Standard Layout

The following drawings depict the standard layout for the range. They are included at the end of this document.

MPMG Standard Layout

MPMG Electrical Layout

Down Range

NUMBER FEATURE RDG SECTION

20 Stationary Armor Target SAT

24 Moving Infantry Target – 15M MIT

34 Stationary Infantry Target SIT

28 Double Target Arm - Stationary Infantry

Target

SIT

22 Widened Stationary Infantry Target SIT

28 Iron Maiden Target SIT

8 Iron Maiden Pad SIT

10 Target Boots Target Boots

10 2-Man Fighting Position Fighting Positions

4 Sniper Firing Pad Fighting Positions

M u lt ip u rp o s e

M a c h in e

G u n R a n g e

M

P M

G

M a rc h

L P

-M C

X R a n g e

D e s ig n G u

4 Vehicle Firing Pad Fighting Positions

ROCA

NAME SIZE UOM RDG SECTION

Control Tower – Small Arms 1 EA Range Control Towers

Operations/Storage Building, Standard 800 SF Ops/Stg Buildings

Classroom Facility 800 SF Classroom and AAR

Facilities Part 1

Classroom and AAR

Facilities Part 2

Latrine: Vault (Latrine: Water) 330

(550)

SF Latrines

Bleacher Enclosure 1 EA Bleacher Enclosure

Covered Mess 800 SF Covered Mess

Ammunition Breakdown Building 185 SF Ammunition Breakdown

Building

Design

Use the standard MPMG layout referenced above as the basis for the range.

The MPMG is a lane based qualification range. Each lane is a minimum of 20M wide at the baseline and widens to 100m wide at 800M downrange. The standard has two different lane configurations, four heavy and six light lanes. The standard shows the heavy lanes at the center, however, that is adjustable based on SDZ and/or land constraints. The light lanes extend to 800M and have a SIT target at 100M intervals. They support SAW and other light machineguns. The heavy lanes extend to 1500M and have a variety of SIT, MIT, SAT, and Iron Maiden targets at the 100M bands. The heavy lanes also include vehicle-firing pads and the SFF overlay.

General Range Design Requirements

This section contains references to the general range design sections of the RDG. Use both the general section for a specific item or structure and the design requirements in this document specific to the MPMG as the basis for the range design.

General

Fire Detection/Protection

LEED

Furniture

ADA

Utility Services

Civi l Range Design

Siting Considerations

Roads/Trails/Parking

M u lt ip u rp o s e

M a c h in e

G u n R a n g e

M

P M

G

M a rc h

L P

-M C

X R a n g e

D e s ig n G u

Target Protection Design Curves

Line of sight

Topographic Surveying

Surface Danger Zones

Electrical Range Design

Data Termination Rack

Downrange Power and Data Distribution – General

Downrange Power and Data Distribution – Over 300M

Target Feeder Voltage Drop Spreadsheet/Instructions

ROCA

Refer to the ROCA-General section of the RDG for general design information. Base the ROCA for the MPMG on the Small Arms ROCA.

Firing Line

Provide fighting positions along the firing line for each lane. Fighting positions should be on slightly elevated ground and designated with numbered markers. Two-man fighting positions are required in each lane. The middle four (Heavy Machine Gun) lanes generally use the combination position. The combination position has foxhole, prone, and sniper positions along with an area for firing vehicle mounted weapons. Refer to the standard fighting positions shown in the Civil Details.

Down Range

Refer to standard drawing at the end of this document for a standard MPMG range layout. The range has 10 lanes, each 25 meters wide at the firing line, becoming wider as the distance from the firing line increases. Typical lane width at 800 meters from the firing line is 100 meters.

Adjust the lane layout, if necessary, based on the terrain.

All 10 lanes support light machine gun qualification. Lanes 4-7 also support heavy machine gun and sniper training.

Use one of the three different emplacement configurations (check, linear, or linear) with depth for the SIT targets at 600 and 800. The configurations are: (see the Civil Details in the Appendix of this document). To make the best use of existing terrain, the lanes may, but do not have to, use the same configuration. Wire the arrays at these two distances, and other target groups where economically feasible, as clusters; refer to the SIT Cluster Section for additional information.

Keep the distance from the firing line to the target as close to the standard distance as possible.

The distance may vary up to 5 meters in order to avoid undesirable locations such as depressions or drainage features without an exception to standard. Larger distance adjustments are possible especially at the longer distances, but require the approval of TCM Range, RTLP MCX, and the

Installation. The targets in each lane should not line up; move them left and right within each lane to avoid bad locations, improve visibility, and increase training effectiveness.

http://apps.hnc.usace.army.mil/rdg/files/Data%20Termination%20Rack.pdf http://apps.hnc.usace.army.mil/rdg/files/Downrange%20Power%20&%20Data%20Distribution%20-%20General.pdf

M u lt ip u rp o s e

M a c h in e

G u n R a n g e

M

P M

G

M a rc h

L P

-M C

X R a n g e

D e s ig n G u

Line of Sight

Provide Line of Sight from each firing position to all targets within that particular lane. Provide a view shed from the sniper positions for installation trainers to determine if sufficient areas are visible for placing iron maiden targets at unknown distances. Prepared positions may be required if sufficient areas are not visible. LoS is also required to the limit and lane markers. In addition, provide LoS from the control tower as required in the Control Tower Section of the RDG.

Refer to the Line of Sight Section of the RDG for LoS requirements, procedures, and submittal requirements.

Targetry

The MPMG used fully automated targets with event-specific, computer-driven target scenarios and scoring. The targetry computer in the Control Tower controls the targets through the target data network. The target data network is generally hard-wired out to 800 meters. The 1200 and

1500M are typically Radio Frequency (RF) controlled. Refer to the Electrical Range Design

Section of the RDG for further information. The computer captures the scoring data, which is then available to the unit for after action review (AAR).

Requirement Documents

Refer to Training Circular TC 25-8, Training Ranges, for additional information and references to the FMs, ARTEPs, TCs, etc. that describe and require the training on this type of range. The latest TC 25-8 is available at Army Knowledge Online (www.us.army.mil) and the General

Dennis J. Reimer Training and Doctrine Digital Library (www.train.army.mil).

Additional Information

None http://www.us.army.mil/ file:///C:/Users/a0edcreh/Desktop/Range%20Standards/RDG%20Official%20Files/Standard%20Ranges/Narrative%20Descriptions/Working/www.train.army.mil

M u lt ip u rp o s e

M a c h in e

G u n R a n g e

M

P M

G

M a rc h

L P

-M C

X R a n g e

D e s ig n G u

DOWNRANGE

DISTANCE

(METERS)

OUTSIDE

LANES

1 thru 3

8 thru 10

CENTER

LANES

4 thru 7

100 SIT MIT

200 SIT MIT

300 SIT MIT

400 Widened SIT (2 SIT's) SAT, MIT, and SIT (DTA)

500 SIT (DTA) MIT and Widened SIT (2 SIT's)

600 SIT (DTA) MIT, SAT and SIT Array (Detail 1)

700 SIT (DTA) Widened SIT (2 SIT's)

800 SIT (DTA) SAT and SIT Array (Detail 1)

1100 SAT

1500 SAT

EMPLACEMENT TYPE

DTA - Double Target Arm

DOWNRANGE

DISTANCE

(METERS)

OUTSIDE

LANES

1 thru 3

8 thru 10

CENTER

LANES

4 thru 7

100 SIT MIT

200 SIT MIT

300 SIT MIT

400 Widened SIT (2 SIT's) SAT, MIT, and SIT (DTA)

500 SIT (DTA) MIT and Widened SIT (2 SIT's)

600 SIT (DTA) MIT, SAT and SIT Array (Detail 1)

700 SIT (DTA) Widened SIT (2 SIT's)

800 SIT (DTA) SAT and SIT Array (Detail 1)

900 IM Pad

1000 IM Pad

1100 SAT

1500 SAT

EMPLACEMENT TYPE

DTA - Double Target Arm

File details come from the government source that posted it. Updated .