B-3 RQLH189009 NORTHCOM Construct Alert Facility Drawings.pdf
PDF 32 MB Posted
- Attached to
- Alert Facility and Alert Apron Federal contract opportunity
- Solicitation number
- N69450-20-R-0129
About this file
This solicitation is for the construction of an Alert Facility and Alert Apron at NAS JRB New Orleans. The project includes building an Aerospace Control Alert Facility and Alert Apron to accommodate the mission, designed as permanent construction according to UFC criteria. The Alert Facility requires two aircraft shelters with drive-through capability, alert quarters with Alternate Command Post capabilities and a secure area. Standby power and pile foundations are also required. The Alert Apron requires all utilities, communications support, exterior lighting, security upgrades, a parking apron for two alert aircraft, and pile foundations. The contract will be a firm-fixed-price DBB construction contract not to exceed $100 million, with a completion schedule of 1300 calendar days from award. The solicitation is full and open competition issued by the Naval Facilities Engineering Command on behalf of the Department of the Navy.
View the file
Other files for this federal contract opportunity
Show all 50
Alert Facility and Alert Apron has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 5 APRIL 2012
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DE
PA
RT
ME
NT
O
F
TH
E
NA
VY
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
C
OM
MA
ND
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
S O
U
TH
EA
ST
DESIGN MANAGER
CHIEF ENG/ARCH
NA
VA
L A
IR
S
TA
TI
ON
JA
CK
SO
NV
ILL
E
SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
CONSTRUCT ALERT FACILITIES
B-3 SUBMITTAL FEBRUARY 28, 2020
3D CREW QUARTERS
PROJECT NO. RQLH189009
CHIEF ARCHITECT-
CHIEF STRUCTURAL -
CHIEF CIVIL -
CHIEF FIRE PROTECTION-
CHIEF MECHANICAL -
CHIEF ELECTRICAL -JOANNE DIZ, P.E.
DANIEL J KIRSCH, R.A.
GIL SAMSON, P.E.
BRYAN PRATT, P.E.
DOUG A. HENRY, P.E.
RONNIE PERRON, P.E.
ALAN KOUCHINSKY, P.E.PROJECT MANAGER -
DESIGN ARCHITECT -
DESIGN STRUCTURAL -
DESIGN CIVIL /SITE -
DESIGN FIRE PROTECTION -
DESIGN MECHANICAL -
DESIGN ELECTRICAL -
B-3 SUBMITTAL 02/28/2020
FIRE PROTECTION
PROJECT MANAGER
ANTHONY DISANTO
Michelle Contestabile
HOLLY KING
JOANNE DIZ
MICHELLE CONTESTABILE, P.E.DESIGN MANAGER - ROBERT W. PRICE, P.E.DESIGN CIVIL /AIRFIELD JEFF FRANK, P.E.
ANTHONY DISANTO, P.E.
JAMES WARD, P.E.
RAMÓN H. FLORES, P.E.
HOLLY KING, R.A.
KURT W. WITTMAN, P.E.
IP
T
SO
U
TH
EA
ST
1621243
N69450-XX-C-XXXX
15135242
G000
NO
RT
HC
OM
R
EP
LA
CE
A
LE
RT
C
OM
PL
EX
C
O
VE
R S
H
EE
T
N
AS
J R
B N
EW
O
R
LE
AN
S
BE
LL
E C
H
AS
SE
, L
O U
IS
IA
N A
DJK DJK DJK
1 164
BELLE CHASSE, LOUISIANA
NAS JRB NEW ORLEANS
NORTHCOM REPLACE ALERT COMPLEX
CONTESTABILE.MIC
HELLE.1009694478
Digitally signed by
CONTESTABILE.MICHELLE.1009694478
Date: 2020.08.06 14:02:18 -04'00'
KIRSCH.DANIEL.J.15236
73889
Digitally signed by
KIRSCH.DANIEL.J.1523673889
Date: 2020.08.06 14:19:42 -04'00'
HENRY.DOUGLAS.A.1
383618289
Digitally signed by
HENRY.DOUGLAS.A.1383618289
Date: 2020.08.06 15:53:02 -04'00'
PRATT.BRYAN.C.100
9043795
Digitally signed by
PRATT.BRYAN.C.1009043795
Date: 2020.08.06 16:04:32 -04'00'
DIZ.JOANNE.E.1397838
Digitally signed by
DIZ.JOANNE.E.1397838826
Date: 2020.08.06 16:42:39 -04'00'
SAMSON.GIL.GERARD.153
0020521
Digitally signed by
SAMSON.GIL.GERARD.1530020521
Date: 2020.08.10 11:45:31 -04'00'
KOUCHINSKY.ALAN.JOHN.13
65370458
Digitally signed by
KOUCHINSKY.ALAN.JOHN.1365370458
Date: 2020.08.10 20:22:20 -04'00'
PERRON.RONNIE.
D.1369516767
Digitally signed by
PERRON.RONNIE.D.1369516767
Date: 2020.08.11 14:30:51 -04'00'
FLORES.RAMON.H.138333
Digitally signed by
FLORES.RAMON.H.1383332679
Date: 2020.08.12 11:58:12 -04'00'
WARD.JAMES.E.1
386951132
Digitally signed by
WARD.JAMES.E.1386951132
Date: 2020.08.12 15:14:56 -04'00'
PRICE.ROBERT.W.JR
.1392492875
Digitally signed by
PRICE.ROBERT.W.JR.1392492875
Date: 2020.08.17 10:40:13 -04'00'
DISANTO.ANTHONY.
M.1091099671
Digitally signed by
DISANTO.ANTHONY.M.1091099671
Date: 2020.08.17 12:17:11 -04'00'
WITTMAN.KURT.W.11
99185183
Digitally signed by
WITTMAN.KURT.W.1199185183
Date: 2020.08.17 13:16:18 -04'00'
FRANK.JEFFREY.W
ADE.1013317115
Digitally signed by
FRANK.JEFFREY.WADE.1013317115
Date: 2020.08.18 08:30:15 -04'00'
KING.HOLLY.M.1385
250165
Digitally signed by
KING.HOLLY.M.1385250165
Date: 2020.08.18 13:56:22 -04'00'
GENERAL NOTES
THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO
DIMENSIONS INDICATED ON DIMENSION PLANS, SHOP DRAWINGS,
OR ESTABLISHED FIELD DIMENSIONS. WHERE NO DIMENSIONS OR
METHOD OF DETERMINING A LOCATION IS GIVEN, VERIFY WITH
ARCHITECT PRIOR TO PROCEEDING.
1.
VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY
CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER
BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.
2.
PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR
MATERIALS.
4.
SEE INTERIOR DRAWINGS FOR DESIGNATION OF BOTH OWNER
AND CONTRACTOR FURNISHED / INSTALLED FURNITURE AND
EQUIPMENT ITEMS
6.
EQUIPMENT SHOWN WITH DASHED-DOT LINES IS EQUIPMENT NOT IN
CONTRACT AND FURNISHED BY THE OWNER. REFER TO OWNER
FURNISHED EQUIPMENT BOOK FOR SOME EQUIPMENT THAT
REQUIRES UTILITY CONNECTIONS IN CONTRACT.
5.
IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,
PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT
GREATER THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT
PRIOR TO PROCEEDING.A. VERTICAL CONTROL JOINTS FOR ANY
WALL LENGTH ARE TO OCCUR AT NOT MORE THAN 30'-0" O.C. IN THE
HORIZONTAL DIRECTION, UNLESS NOTED OTHERWISE.
3.
7. COORDINATE PLACEMENT OF FIRE ALARM HORN STROBES WITH
ARCHITECT.
8. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING-
MOUNTED PROCEDURE LIGHTS. COORDINATE WEIGHT AND
MOUNTING PLATE REQUIREMENTS W/ STRUCTURAL.
DIMENSIONS SHOWN ARE TO FACE OF STUD OR CMU (U.N.O.).9.
ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND
MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF
MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN
THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT
TO THE <<<ARCHITECT OR CONTRACTING OFFICER'S>>> ATTENTION
PRIOR TO PROCEEDING WITH THE WORK.
PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES
AND AS REQUIRED FOR MECHANICAL EQUIPMENT AND PLUMBING
WORK. ALL ACCESS PANELS SHALL BE CONCEALED AND
LOCATIONS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO
PROCEEDING.
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 5 APRIL 2012
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DE
PA
RT
ME
NT
O
F
TH
E
NA
VY
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
C
OM
MA
ND
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
S O
U
TH
EA
ST
NA
VA
L A
IR
S
TA
TI
ON
JA
CK
SO
NV
ILL
E
SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
B-3 SUBMITTAL 02/28/2020
DESIGN MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
PROJECT MANAGER
ANTHONY DISANTO
Michelle Contestabile
HOLLY KING
JOANNE DIZ
3/16" = 1'-0"
IP
T
SO
U
TH
EA
ST
1621243
N69450-XX-C-XXXX
G001
NO
RT
HC
O
M R
EP
LA
CE
A
LE
RT
C O
M
PL
EX
SH
EE
T
IN
D
EX
G
EN
ER
AL
N O
TE
S
N
AS
J R
B N
EW
O
R
LE
AN
S
BE
LL
E C
H
AS
SE
, L
O U
IS
IA
N A
DJK
2 164
15135243
MECHCANICAL SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG NO.
M001 GENERAL NOTES SYMBOLS AND LEGEND 15135341
M011 MECHANICAL SCHEDULES 15135342
M012 MECHANICAL SCHEDULES 15135343
M013 MECHANICAL SCHEDULES 15135344
M101 ACQ & ECP HVAC PLAN 15135345
M102 ACQ & ECP PIPING PLAN 15135346
M401 ENLARGED MECHANICAL PLAN AND SECTIONS 15135347
M402 MECHANICAL SECTIONS 15135348
M501 MECHANICAL DETAILS 15135349
M502 MECHANICAL DETAILS 15135350
M503 MECHANICAL DETAILS 15135351
M601 MECHANICAL CONTROLS 15135352
M602 MECHANICAL CONTROLS 15135353
M603 MECHANICAL CONTROLS 15135354
M604 MECHANICAL CONTROLS 15135355
M605 MECHANICAL CONTROLS 15135356
M901 MECHANICAL ISOMETRICS 15135357
M902 MECHANICAL ISOMETRICS 15135358
A701 INTERIOR FINISH PLAN
A702 FINISH LEGEND AND SCHEDULE
A703 FURNITURE PLAN
A711 INTERIOR ELEVATIONS AND DETAILS
A712 INTERIOR ELEVATIONS AND DETAILS
A731 INTERIOR SIGNAGE
LS001 LIFE SAFETY - CODE CRITERIA - ACQ
LS002 LIFE SAFETY - CODE CRITERIA - ALT CP
LS003 LIFE SAFETY - CODE CRITERIA - SHELTER #1
LS004 LIFE SAFETY - CODE CRITERIA - SHELTER #2
LS101 LIFE SAFETY PLAN - ACQ
LS102 LIFE SAFETY PLAN - ALT CP
LS103 LIFE SAFETY PLAN - SHELTER #1
LS104 LIFE SAFETY PLAN - SHELTER #2
FA001 FIRE ALARM & MASS NOTIFICATION NOTES & LEGEND
FA100 ACOUSTICALLY DISTINGUISHABLE SPACES
FA101 FIRE ALARM & MASS NOTIFICATION - ACQ
FA102 FIRE ALARM & MASS NOTIFICATION - SHELTER #1
FA103 FIRE ALARM & MASS NOTIFICATION - SHELTER #2
FA104 FIRE ALARM & MASS NOTIFICATION - ALT CP
FA201 SEQUENCE OF OPERATIONS & RISER DIAGRAM
FA202 FIRE ALARM & MASS NOTIFICATION NETWORK
FX001 FIRE SUPPRESSION NOTES SYMBOLS & LEGENDS
FX002 FLIGHTLINE FIRE WATER DISTRIBUTION PLAN
FX100 HARZARD CLASSIFICATION
FX101 FIRE SUPPRESSION PLAN - ACQ
FX102 FIRE SUPPRESSION PLAN - SHELTER #1
FX103 FIRE SUPPRESSION PLAN - SHELTER #2
FX104 FIRE PROTECTION PLAN - SHELTER #1
FX105 FIRE PROTECTION PLAN - SHELTER #2
FX106 FIRE PROTECTION PLAN - ALT CP
FX201 FIRE PROTECTION - HEF SYSTEM DETAILS
FOR ALL CIVIL WORK FOR THIS PROJECT SEE FY19 CONSTRUCT
ALERT APRON. CONTRACTOR IS TO COORDINATE ALL CIVIL WORK
IN FY19 DRAWINGS WITH THE FY20 CONSTRUCT ALERT FACILITY
DRAWINGS.
E001 ELEC ABBREVIATIONS AND SYMBOLS LEGEND
EL101 AIR CREW QUARTERS & ENTRY CONTROL FACILITY -
LIGHTING PLAN
EL102 AIRCRAFT SHELTER #1 - LIGHTING PLAN
EL103 AIRCRAFT SHELTER #2 - LIGHTING PLAN
EL104 AIR CREW QUARTERS LIGHTING CALCULATIONS
EL105 ECP & LOX LIGHTING CALCULATIONS
EL106 AIRCRAFT SHELTER #1 LIGHTING CALCULATIONS
EL107 AIRCRAFT SHELTER #2 LIGHTING CALCULATIONS
EP101 AIR CREW QUARTERS & ENTRY CONTROL FACILITY -
POWER PLAN
EP102 AIRCRAFT SHELTER #1 - POWER PLAN
EP103 AIRCRAFT SHELTER #2 - POWER PLAN
EP104 MECHANICAL EQUIPMENT POWER PLAN
EP105 AIRCRAFT SHELTER #1 - HAZARDOUS LOCATION MAP
EP106 AIRCRAFT SHELTER #2 - HAZARDOUS LOCATION MAP
EP107 AIRCRAFT SHELTER #1 - HAZARDOUS LOCATION MAP
EP108 AIRCRAFT SHELTER #2 - HAZARDOUS LOCATION MAP
ET101 AIR CREW QUARTERS & ENTRY CONTROL FACILITY -
TELECOMM PLAN
ET102 AIRCRAFT SHELTER #1 - TELECOMM PLAN
ET103 AIRCRAFT SHELTER #2 - TELECOMM PLAN
ESG101 GROUNDING SITE PLAN
ESL101 EXTERIOR LIGHTING PLAN
ESL102 EXTERIOR LIGHTING PLAN
ESL103 EXTERIOR LIGHTING PLAN
ESL104 APRON LIGHTING CALCULATIONS
ESL105 SITE LIGHTING CALCULATIONS
ELP101 AIR CREW QUARTERS & ENTRY CONTROL FACILITY -
LIGHTNING PROTECTION
ELP102 AIRCRAFT SHELTER #1 - LIGHTNING PROTECTION
ELP103 AIRCRAFT SHELTER #2 - LIGHTNING PROTECTION
ELP104 AIRCRAFT SHELTER #1 - ZONE OF PROTECTION
ELP105 AIRCRAFT SHELTER #2 - ZONE OF PROTECTION
ELP106 AIRCRAFT SHELTER #1 AND #2 - ZONE OF PROTECTION
ELP107 AIRCRAFT SHELTER #1 - ZONE OF PROTECTION
ELP108 AIRCRAFT SHELTER #2 - ZONE OF PROTECTION
ELP109 AIRCRAFT SHELTER #1 AND #2 - ZONE OF PROTECTION
E501 ELECTRICAL DETAILS
E502 ELECTRICAL DETAILS
E503 ELECTRICAL DETAILS
E504 ELECTRICAL DETAILS
E505 ELECTRICAL DETAILS
E506 ELECTRICAL DETAILS
E507 ELECTRICAL DETAILS
E601 RISER DIAGRAM
E602 RISER DIAGRAM
E603 RISER DIAGRAM
E701 ELECTRICAL SCHEDULES
E702 ELECTRICAL SCHEDULES
ARCHCITECT SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
A001 ARCHITECTURAL SITE PLAN 15135273
A101 ACQ & ECP/ALT CP FIRST FLOOR PLAN 15135274
A111 ACQ & ECP/ ALT CP REFLECTED CEILING PLAN 15135275
A121 ACQ & ECP/ALT CP ROOF PLAN 15135276
A151 SHELTER #1 FLOOR PLAN 15135277
A152 SHELTER #2 FLOOR PLAN 15135278
A153 HAZMAT & EQUIP STORAGE BLDG 15135279
A154 OXYGEN STOR FLR / ROOF PLANS/ ELEVS & BLDG SECT 15135280
A201 ACQ & ECP EXTERIOR ELVATIONS 15135281
A251 SHELTER #1 EXTERIOR ELVATIONS 15135282
A252 SHELTER #2 EXTERIOR ELVATIONS 15135283
A301 ACQ & ECP BUILDING SECTIONS 15135284
A302 ACQ WALL SECTIONS 15135285
A303 ACQ & ECP WALL SECTIONS 15135286
A351 SHELTER #1 BUILDING SECTIONS 15135287
A352 SHELTER #2 BUILDING SECTIONS 15135288
A353 SHELTER WALL SECTIONS 15135289
A401 ACQ ENLARGED FLOOR PLANS & INTERIOR
ELEVATIONS
15135290
A402 ECP ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS 15135291
A403 CASEWORK DETAILS & SECTIONS 15135292
A501 ACQ & ECP/ALT ROOF DETAILS 15135293
A502 SECTIONS AND PLAN DETAILS 15135294
A601 DOOR / WINDOW ELEVATIONS & DOOR SCHEDULE 15135295
A602 DOOR, WINDOW & LOUVER DETAILS 15135296
A603 HEAD JAMB & SILL DOOR DETAILS 15135297
A604 PARTITION TYPE 15135298
CIVIL SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
ELEC SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
GENERAL SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG NO.
G000 COVER SHEET 15135242
G001 SHEET INDEX & GENERAL NOTES 15135243
G002 DRAWING ABBREVATIONS, LEGEND & LOCATION MAPS 15135244
G003 ADA MOUNTING HEIGHTS & DETAILS 15135245
INTERIORS SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
STRUCTURAL SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG NO.
S001 GENERAL NOTES & DESIGN CRITERIA 15135253
S002 GENERAL NOTES & DESIGN CRITERIA 15135254
S003 COMPONENT & CLADDING WIND PRESSURES 15135255
S100 OVERALL SITE PLAN & ISOMETRIC VIEW 15135256
S101 ACQ & ECP SLAB & FOUNDATION PLAN 15135257
S151 SHELTER #1 PILE & FOUNDATION PLAN 15135258
S152 SHELTER #1 SLAB PLAN 15135259
S153 SHELTER #2 PILE & FOUNDATION PLAN 15135260
S154 SHELTER #2 SLAB PLAN 15135261
S155 HAZ MAT & LOX STORAGE BUILDINGS 15135262
S301 ACQ & ECP ROOF FRAMING PLAN 15135263
S351 SHELTER #1 ADD'L ROOF LOADING PLAN 15135264
S352 SHELTER #2 ADD'L ROOF LOADING PLAN 15135265
S501 ACQ & ECP FOUNDATION SECTIONS & DETAILS 15135266
S502 ACQ & ECP FOUNDATION SECTIONS & DETAILS 15135267
S503 SHELTER FOUNDATION SECTIONS & DETAILS 15135268
S504 SHELTER FOUNDATION SECTIONS & DETAILS 15135269
S510 ROOF SECTIONS & DETAILS 15135270
S511 ROOF SECTIONS & DETAILS 15135271
S601 TYPICAL MASONRY DETAILS 15135272
LIFE SAFETY
SHEET SHEET TITLE NAVFAC DWG. NO.
PLUMBING SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
FIRE PROTECTION SHEET INDEX
SHEET SHEET TITLE NAVFAC DWG. NO.
15135246 15135247 15135248 15135249 15135250 15135251 15135252 15135253
15135299 15135300 15135301 15135302 15135303 15135304
15135305 15135306 15135307 15135308 15135309 15135310 15135311 15135312 15135313 15135314 15135315 15135316 15135317 15135318 15135319 15135320 15135321 15135322
P001 GENERAL NOTES SYMBOLS AND LEGENDS
P011 PLUMBING EQUIPMENT SCHEDULES
P101 OVERALL CREW QUARTERS PLUMBING PLAN
P102 OVERALL ECP PLUMBING FLOOR PLAN
P103 OVERALL SHELTER 1 PLUMBING PLAN
P104 OVERALL SHELTER 2 PLUMBING PLAN
P401 ENLARGED CREW SANITARY PLAN NORTH
P402 ENLARGED CREW SANITARY PLAN SOUTH
P403 ENLARGED CREW PIPING PLAN NORTH
P404 ENLARGED CREW PIPING PLAN SOUTH
P501 PLUMBING DETAILS
P502 PLUMBING DETAILS
P503 PLUMBING DETAILS
P601 CREW SANITARY RISERS NORTH
P602 CREW SANITARY RISERS SOUTH
P603 CREW PIPING RISERS NORTH
P604 CREW PIPNG RISERS SOUTH
P605 ECP RISERS
15135323 15135324 15135325 15135326 15135327 15135328 15135329 15135330 15135331 15135332 15135333 15135334 15135335 15135336 15135337 15135338 15135339 15135340
15135359 15135360
15135361 15135362 15135363 15135364 15135365 15135366 15135367
15135368 15135369 15135370 15135371 15135372 15135373 15135374 15135375
15135376 15135377 15135378 15135379 15135380 15135381 15135382 15135383 15135384
15135385 15135386 15135387 15135388 15135389 15135390 15135391 15135392 15135393 15135394 15135395 15135396 15135397 15135398 15135399 15135400 15135401 15135402 15135403 15135404
DRAWING ABBREVIATIONS INDEX OF DRAWINGS
LEGEND
NUMBERING SYSTEM:
A2.10/01
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
SERIES NUMBER
SHEET NUMBER WITHIN SERIES
NUMBER OF PLAN, DETAIL, ETC.
ON SHEET
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS SEMI RIGID
INSULATION
FIBERGLASS BATT
INSULATION
MINERAL WOOL SEMI RIGID
INSULATION
EXPANDED POLYSTYRENE
RIGID INSULATION
EXTRUDED POLYSTYRENE
RIGID INSULATION
POLYISOCYANURATE RIGID
INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
MATERIALS
ANNOTATION CALLOUTS/DRAWING SYMBOLS
LOCATION MAP
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED INSTALLED BY
GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
1i
0 COLUMN LINE
DESIGNATOR
EQUIPMENT NUMBER
DOOR NUMBER
INTERIOR ELEVATION
1i
WALL TYPE
WINDOW TYPE
A101
SIM
SECTION
Room name
101 ROOM NAME/NUMBER
A101
Ref
A101
Ref
EXTERIOR ELEVATION
1 REVISION TAG
A-101
SIM
PLAN, BLOW-UP DETAIL
PLAN NORTH
NORTH ARROW w/
TRUE NORTH INDICATION
SPOT ELEVATION
Name Elevation FLOOR LEVEL & NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
H -------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED INSTALLED
BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
A
EGRESS ROUTE ID
AND SECTION
LENGTH
S
1 HR FIRE
S S S
1 HR FIRE/SMOKE WALL
4 HR FIRE
4 HR FIRE/SMOKE WALL
2 HR FIRE
2 HR FIRE/SMOKE WALL
3 HR FIRE
3 HR FIRE/SMOKE WALL
FIRE RATED WALL SYMBOLS:
SHEET KEYNOTE Room Rm_Occupancy
150 SF
EGRESS :Egress_ID Egress_Length
ROOM OCCUPANCY &
AREA
SITE LOCATION
0 EXTER WALL LINE
DESIGNATOR
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 5 APRIL 2012
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DE
PA
RT
ME
NT
O
F
TH
E
NA
VY
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
C
OM
MA
ND
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
S O
U
TH
EA
ST
NA
VA
L A
IR
S
TA
TI
ON
JA
CK
SO
NV
ILL
E
SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
B-3 SUBMITTAL 02/28/2020
DESIGN MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
PROJECT MANAGER
ANTHONY DISANTO
Michelle Contestabile
HOLLY KING
JOANNE DIZ
3/16" = 1'-0"
IP
T
SO
U
TH
EA
ST
1621243
N69450-XX-C-XXXX
G002
NO
RT
HC
O
M R
EP
LA
CE
A
LE
RT
C O
M
PL
EX
D
R
AW
IN
G
A
BB
R
EV
AT
IO
N S, L
EG
EN
D
L
O C
AT
IO
N M
AP
S
N
AS
J R
B N
EW
O
R
LE
AN
S
BE
LL
E C
H
AS
SE
, L
O U
IS
IA
N A
3 164
15135244
WATER CLOSET
SCALE: 1/2" = 1'-0"
URINAL - STANDARD URINAL -
ACCESSIBLE
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
TO
T
O P
" M
AX
2'
0"
GRAB BAR (GB-2)
GRAB BAR
(GB-2)
SCALE: 1/2"=1'-0"
MAX.
1' - 0" 42" MIN.
TO
T
O P
O F
" M
IN
" M
AX
GRAB BAR (GB-1)
SCALE: 1/2"=1'-0"
36" MIN.
TO
T
O P
O F
" M
IN
" M
AX
GRAB BAR
(GB-1)
TOILET TISSUE
DISPENSER (TTD)
SCALE: 1/2"=1'-0"
M
IN
1'
3"REAR
WALL
SIDE
WALL
C
LE
AR
" M
IN
C O
U N
TE
R
H G
T.
" M
AX
TO
T
O P
O F
R
IM
" M
AX
C
LE
AR
" M
IN
TO
T
O P
O F
R
IM
" M
AX
15" MIN.
LAVATORY
SCALE: 1/2" = 1'-0"
LAVATORY
SCALE: 1/2" = 1'-0"
15" MIN.
MIRROR -
FRAMED (MF)
MIRROR -
FRAMED
" M
AX
TO
B
O
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C
E
SCALE = 1/2" = 1'-0"
SND LOCATION
(LOCATE BELOW
GRAB BAR)
SCALE: 1/2"=1'-0"
SANITARY NAPKIN
DISPOSER (SND)
SANITARY NAPKIN &
TAMPON DISPENSER
(SNTD)
O
PE
R
AB
LE
P
O R
TI
O
N
" M
AX
. T O
T O
P O
F
SCALE: 1/2"=1'-0"
MOP & BROOM
HOLDER (MH)
ROBE HOOK (RH)
SOAP DISPENSER
(SD-1)
SHOWER
COMPARTMENT
CONTROLS (SCC)
PAPER TOWEL
DISPENSER (PTD)
FIRE VALVE
CABINET & FIRE
EXTINGUISHER
CABINET (FEC)
DRINKING
FOUNTAIN
DRINKING
FOUNTAIN
SHOWER CURTAIN
ROD (SCR)
FIRE
EXTINGUISHER (FE)
TELEPHONE
FOLDING SHOWER
SEAT (FSS)
SOAP
HOLDER (SH)
PTD
PAPER TOWEL
DISPENSER / WASTE
RECEPTACLE (PTDWR)
SCALE: 1/2"=1'-0"
NOTE: CABINET SHALL
NOT PROJECT MORE
THAN 4" FROM WALL.
SCR
SHEET NOTES:
FSS
RH
SOAP
DISPENSER
SH
COUNTERTOP
D
IS
PE
N
SE
R
O U
TL
ET
" M
AX
. T
O
PA
PE
R
T O
W
EL
C O
U N
TE
R
H G
T.
" M
AX
TO
T
O P
O F
C
AB
IN
ET
" M
AX
TO
T
O P
O F
F.
E.
" M
AX
6'
0"
" M
AX
" M
AX
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0"SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
SCALE: 1/2"=1'-0"
" M
AX
" M
IN
D
IS
PE
N
SE
R
O U
TL
ET
" M
AX
. T
O
PA
PE
R
T O
W
EL
32" MIN.
6'
0"
O
PE
R
AB
LE
P
O R
TI
O
N 4'
"T O
T O
P O
F
O
PE
R
AB
LE
P
O R
TI
O
N
" M
AX
. T O
T O
P O
F
1. THIS SHEET INDICATES TYPICAL AND ACCESSIBLE MOUNTING
HEIGHTS AND ADDITIONAL CRITERIA.
2. THE ACCESSIBLE CRITERIA INDICATED ON THIS SHEET ARE IN
COMPLIANCE WITH THE ADA STANDARDS FOR ACCESSIBLE
DEISGN (2010) AND THE ABA ACCESSIBILITY STANDARD FOR
DEPARTMENT OF DEFENSE FACILITIES (2008).
3. DETAILS ON THIS SHEET INDICATING ACCESSIBLE REQUIREMENTS
ARE MARKED WITH THE "INTERNATIONAL SYMBOL OF
ACCESSIBILITY".
4. VERIFY MANUFACTURER'S RECOMMENDED ACCESSIBLE
MOUNTING LOCATIONS WITH THOSE LISTED ON THIS SHEET.
COUNTERTOP
TO
T
O P
O F
S
EA
T
O F
R
IM G
R
IP
PI
N G
SU
R
FA
C
E
54" MIN.
G R
IP
PI
N G
SU
R
FA
C
E
" M
AX
CL
TTD OUTLET
LOCATION
7" MIN.
9" MAX.
24" MIN.
MIN.
1' - 0"
CL
TTD LOCATION
C
LE
AR
" M
IN
SCRS
SC
PROVIDE SHOWER
CURTAIN - SC AND
SHOWER CURTAIN
RINGS - SCR AT
EACH SHOWER
CURTAIN ROD (SCR)
" M
AX
" M
IN
TELEPHONE
SCALE: 1/2"=1'-0"
" M
AX
" M
IN
SCC LOCATION
NOTE: SCC SHALL
BE LOCATED ABOVE
GRAB BAR.
C
LE
AR
" M
IN
SP
O
U T
H
EI
G H
T
" M
AX
SP
O
U T
H
EI
G H
T
" M
IN
" M
AX
ACCESSIBLE
KNEE AND TOE
CLEARANCE
NOTES:
1. F.E. SHALL NOT
PROJECT MORE THAN
4" FROM WALL.
2. IF GREATER THAN 40
POUNDS IN WEIGHT,
MOUNT TOP OF F.E. AT
42" MAX. HEIGHT.
"INTERNATIONAL SYMBOL
OF ACCESSIBILITY"
M
IN
1'
3"
CLOTHES
HOOKS (CH)
SCALE: 1/2"=1'-0"
5'
0"
SOAP DISPENSER
(SD-2)
O
PE
R
AB
LE
P
O R
TI
O
N *4
8" M
AX
. T
O
SCALE: 1/2"=1'-0"
*44" MAX. IF LOCATED
OVER AN OBSTRUCTION
MIRROR -
GLASS (MG)
MIRROR -
GLASS
" M
AX
TO
B
O
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C
E
SCALE = 1/2" = 1'-0"
M
IN
. C
LR
1/ 2"
NO
T
FO
R
CO
NS
TR
UC
TI
ON
P R
E
LI
M
IN
A R
Y
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 5 APRIL 2012
CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
DE
PA
RT
ME
NT
O
F
TH
E
NA
VY
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
C
OM
MA
ND
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
S O
U
TH
EA
ST
NA
VA
L A
IR
S
TA
TI
ON
JA
CK
SO
NV
ILL
E
SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
IP
T
SO
UT
H
CE
NT
RA
L
NA
S
JR
B
NE
W
O
RL
EA
NS
BE
LL
E
CH
AS
SE
, L
OU
IS
IA
NA
DESIGN MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
PROJECT MANAGER
ANTHONY DISANTO
Michelle Contestabile
HOLLY KING
JOANNE DIZ
1/2" = 1'-0" 1621243
N69450-XX-C-XXXX
15135245
G003
N O
R
TH
C O
M R
EP
LA
C E
AL
ER
T C
O M
PL
EX
AD
A
M O
U N
TI
N
G H
EI
G
H
TS
D
ET
AI
LS
4 164
SCALE: = 1'-0"
0 8 168
1/8"
ALERT CREW QUARTERS
NAS JRB NEW ORLEANS, LOUISIANA
GENERAL FIRE PROTECTION REQUIREMENTS
BASIC BUILDING CODE INFORMATION
BUILDING & LIFE SAFETY CODE CRITERIA
BUILDING AREA
BUILDING HEIGHT AND NUMBER OF STORIES
BUILDING DESIGN OCCUPANT LOAD
FIRE RESISTANCE RATING OF BLDG ELEMENTS
LS001
B-3 SUBMITTAL
02/28/2020
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
E
A S
T
N O
R
TH
C O
M
C O
N S
TR
U
C T
A
LE
R T
FA
C
IL
IT
IE
S
AutoCAD SHX Text
(PER NFPA TABLE 7.3.1.2)
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
TYPE:
AutoCAD SHX Text
(IBC 602)
AutoCAD SHX Text
DOES BUILDING HAVE ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
WHAT PERCENT OF STORY IS ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
DOES BUILDING REQUIRE INCIDENTAL USE AREA SEPARATION?:
AutoCAD SHX Text
MIXED OCCUPANCIES?:
AutoCAD SHX Text
OCCUPANCY GROUP:
AutoCAD SHX Text
NON SEPARATED?:
AutoCAD SHX Text
SEPARATED?:
AutoCAD SHX Text
TYPE IIB UNPROTECTED, SPRINKLERED, EXTERIOR WALLS OF NON-COMBUSTIBLE MATERIALS
AutoCAD SHX Text ASSEMBLY GROUP A-3 / ASSEMBLY (IBC 303.4, NFPA 101 §6.1.2.1) (IBC 303.4, NFPA 101 §6.1.2.1) BUSINESS GROUP B / BUSINESS (IBC 304.1, NFPA 101 §6.1.11.1) (IBC 304.1, NFPA 101 §6.1.11.1) RESIDENTIAL GROUP R-3 / LODGING (IBC 310.4, NFPA 101 §6.1.8.1.2)(IBC 310.4, NFPA 101 §6.1.8.1.2)
AutoCAD SHX Text N/A
AutoCAD SHX Text
AREA LIMIT (506.1) OF IBC:
AutoCAD SHX Text
TOTAL DESIGNED AREA OF BUILDING:
AutoCAD SHX Text
GROUP A-3 (38,000 SQ. FT), MOST RESTRICTIVE
AutoCAD SHX Text
8,224 SF
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
SEPARATIONS
AutoCAD SHX Text
FIREBLOCKING REQUIRED?:
AutoCAD SHX Text
DRAFTSTOPPING REQUIRED?:
AutoCAD SHX Text
SMOKE CONTROL SYSTEM REQUIRED?:
AutoCAD SHX Text
SMOKE BARRIERS REQUIRED?:
AutoCAD SHX Text
SLEEPING/CORRIDOR UNIT SEPARATION
AutoCAD SHX Text
SMOKE PARTITION REQUIRED?:
AutoCAD SHX Text
FIRE PARTITION REQUIRED?:
AutoCAD SHX Text
INCIDENTAL USE AREAS
AutoCAD SHX Text
FIRE BARRIER REQUIRED?:
AutoCAD SHX Text
FIRE ALARM & DETECTION
AutoCAD SHX Text
PER UFC 3-600-01 §4-34.3
AutoCAD SHX Text
FIRE ALARM & DETECTION SYSTEM REQUIRED?:
AutoCAD SHX Text
SUPPRESSION
AutoCAD SHX Text
STANDPIPES REQUIRED?:
AutoCAD SHX Text
PER UFC 3-600-01 §4-34.2
AutoCAD SHX Text
SPRINKLERS REQUIRED?:
AutoCAD SHX Text
PORTABLE EXTINGUISHERS REQUIRED?:
AutoCAD SHX Text
HOOD SUPPRESSION SYSTEMS REQUIRED?:
AutoCAD SHX Text
SLEEPING ROOM SMOKE DETECTION REQUIRED?:
AutoCAD SHX Text
STRUCTURAL FRAME (PER IBC TABLE 601)
AutoCAD SHX Text
BEARING WALLS
AutoCAD SHX Text
RATING AS REQUIRED (IN HOURS)
AutoCAD SHX Text
BUILDING ELEMENT
AutoCAD SHX Text
RATING AS DESIGNED (IN HOURS)
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
(PER IBC TABLE 601)
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
NONBEARING WALLS & PARTITIONS
AutoCAD SHX Text
(PER IBC TABLE 601 & 602)
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS (PER IBC TABLE 601)
AutoCAD SHX Text
ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS (PER IBC TABLE 601)
AutoCAD SHX Text
FIRE WALLS (PER IBC 706)
AutoCAD SHX Text
FIRE BARRIERS (PER NFPA 101 TABLE 28.3.2.2.2)
AutoCAD SHX Text
**COMPLETE SPRINKLER PROTECTION IN ACCORDANCE WITH NFPA 13.
AutoCAD SHX Text
OCCUPANCY SEPARATION - FIRE BARRIERS (PER IBC 707)
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text N/A
AutoCAD SHX Text
1 HR
AutoCAD SHX Text
1 HR
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
MEANS OF EGRESS
AutoCAD SHX Text
EGRESS WIDTH (PER NFPA 101 TABLE 7.3.3.1)
AutoCAD SHX Text
CODE ITEM
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
EXIT ACCESS TRAVEL DISTANCE ASSEMBLY (PER NFPA 101 PARAGRAPH 12.2.6.2(1))
AutoCAD SHX Text
APPLICABLE CODES
AutoCAD SHX Text
REQUIRED (SPRINKLERED): 250 FEET PROPOSED: 84 FEET
AutoCAD SHX Text
EXIT ACCESS TRAVEL DISTANCE BUSINESS (PER NFPA 101 PARAGRAPH 38.2.6.3)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): 300 FEET PROPOSED: 84 FEET
AutoCAD SHX Text
DEAD END CORRIDOR ASSEMBLY (PER NFPA 101 12.2.5.1.3)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): 20 FEET PROPOSED: NONE
AutoCAD SHX Text
DEAD END CORRIDOR BUSINESS (PER NFPA 101 38.2.5.2.1)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): 50 FEET PROPOSED: NONE
AutoCAD SHX Text
COMMON PATH OF TRAVEL ASSEMBLY (PER NFPA 101 12.2.5.1.2)
AutoCAD SHX Text REQUIRED (SPRINKLERED): 20 FEET; 75 FEET (LESS THAN 50 OCCUPANTS) PROPOSED: 42 FT
AutoCAD SHX Text
COMMON PATH OF TRAVEL BUSINESS (PER NFPA 101 38.2.5.3.2)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): 100 FEET PROPOSED: 42 FT
AutoCAD SHX Text
1. NUMBER OF EXITS:
AutoCAD SHX Text
a. GENERALLY TWO (2) FROM EVERY STORY FLOOR OR MEZZANINE (NFPA 101 §7.4.1.2). GENERALLY TWO (2) FROM EVERY STORY FLOOR OR MEZZANINE (NFPA 101 §7.4.1.2). b. MECHANICAL EQUIPMENT ROOMS, BOILER ROOMS, AND FURNACE ROOMS: A SINGLE EXIT IS ALLOWED PROVIDED IT CAN BE REACHED IN MECHANICAL EQUIPMENT ROOMS, BOILER ROOMS, AND FURNACE ROOMS: A SINGLE EXIT IS ALLOWED PROVIDED IT CAN BE REACHED IN LESS THAN THE 50 FT COMMON PATH OF TRAVEL (NFPA 101 §7.13.1) c. PRIMARY AND SECONDARY MEANS OF ESCAPE REQUIRED FOR SLEEPING ROOM (NFPA 101 §26.2.1.1). PRIMARY AND SECONDARY MEANS OF ESCAPE REQUIRED FOR SLEEPING ROOM (NFPA 101 §26.2.1.1).
AutoCAD SHX Text
2. PROPOSED NUMBER OF EXITS:
AutoCAD SHX Text
a. SIX (6) EXITS FROM NORMALLY OCCUPIED BUILDING AREAS. SIX (6) EXITS FROM NORMALLY OCCUPIED BUILDING AREAS. b. DEDICATED EXIT FROM EACH OF COMMUNICATION, ELECTRICAL, AND MECHANICAL ROOMS.DEDICATED EXIT FROM EACH OF COMMUNICATION, ELECTRICAL, AND MECHANICAL ROOMS.
AutoCAD SHX Text UFC 3-600-01 DESIGN FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016, CHANGE 2, 25 MARCH 2018 INTERNATIONAL BUILDING CODE (IBC) 2015 FOR FIRE RESISTANCE REQUIREMENTS AND AREA LIMITATIONS AS REFERENCED BY UFC 3-600-01, PARAGRAPH 3-2 2015 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2016 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2016 NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES 2017 NFPA 70 NATIONAL ELECTRICAL CODES 2016 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 NFPA 80 STANDARD FOR FIRE DOOR AND OTHER OPENING PROTECTIVES 2015 NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS 2015 NFPA 101 LIFE SAFETY CODE, UFC 4-021-01, MASS NOTIFICATION SYSTEMS, 9 APRIL 2008, CHANGE 1, JANUARY 2010
AutoCAD SHX Text
HEIGHT LIMIT (504.3) AND NUMBER OF STORIES LIMIT (504.4) OF IBC:
AutoCAD SHX Text
75 FT / 3 STORIES
AutoCAD SHX Text NORMALLY OCCUPIED AREAS: 193 OCCUPANTS / 6 EXITS = 32 OCCUPANTS / EXIT COMMUNICATION, ELECTRICAL, AND MECHANICAL ROOMS: 1 OCCUPANT /EXIT TOTAL REQUIRED EXIT CAPACITY (NORMALLY OCCUPIED AREAS): 193 OCCUPANTS X 0.2”/OCCUPANT = 39” /OCCUPANT = 39” TOTAL PROVIDED EXIT CAPACITY (NORMALLY OCCUPIED AREAS): 227” (5 SETS OF SINGLE DOORS @ 34” EACH; 1 SET OF DOUBLE DOORS @ 57” EACH)EACH; 1 SET OF DOUBLE DOORS @ 57” EACH)EACH)
AutoCAD SHX Text
LAUNDRY ROOM; BOILER ROOM
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
EXIT ACCESS TRAVEL DISTANCE RESIDENTIAL (PER NFPA 101 PARAGRAPH 24.2.2.1.1)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): NONE PROPOSED: 50 FEET
AutoCAD SHX Text
DEAD END CORRIDOR RESIDENTIAL (PER NFPA 101 PARAGRAPH 24.2.2.1.1)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): NONE PROPOSED: NONE
AutoCAD SHX Text
COMMON PATH OF TRAVEL RESIDENTIAL (PER NFPA 101 PARAGRAPH 24.2.2.1.1)
AutoCAD SHX Text
REQUIRED (SPRINKLERED): NONE PROPOSED: NONE
AutoCAD SHX Text
CONSTRUCTION CLASSIFICATION
AutoCAD SHX Text
TOTAL DESIGNED HEIGHT OF BUILDING AND NUMBER OF STORIES:
AutoCAD SHX Text
< 75 FT / 1 STORY75 FT / 1 STORY
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
USE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
ALLOWED PER
AutoCAD SHX Text
OCCUPANT
AutoCAD SHX Text
OCCUPANCY
AutoCAD SHX Text
LOAD
AutoCAD SHX Text
BEDROOMS 120 - 127, 138 - 141
AutoCAD SHX Text
RESIDENTIAL
AutoCAD SHX Text
2,054 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GAME/FITNESS 105
AutoCAD SHX Text
653 SF
AutoCAD SHX Text
AutoCAD SHX Text
OPERATION CENTER READY ROOM 106
AutoCAD SHX Text
302 SF
AutoCAD SHX Text
GRAND TOTAL
AutoCAD SHX Text
KITCHEN/DINING 108
AutoCAD SHX Text
CLASSIFIED BRIEF/DEBRIEF 107
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
258 SF
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MAINTENANCE BRIEF/DEBRIEF 109
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
TRAINING ROOM/BREAK ROOM 111
AutoCAD SHX Text
MECHANICAL/ELECTRICAL/COMM ROOMS 116-118
AutoCAD SHX Text
SUPPLY PARK BENCH STOCK 115
AutoCAD SHX Text
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LOUNGE MAINTENANCE READY ROOM 114
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
ASSEMBLY
AutoCAD SHX Text
BUSINESS
AutoCAD SHX Text
CORRIDORS/COMMON USE AREAS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
409 SF
AutoCAD SHX Text
AutoCAD SHX Text
147 SF
AutoCAD SHX Text
AutoCAD SHX Text
183 SF
AutoCAD SHX Text
AutoCAD SHX Text
221 SF
AutoCAD SHX Text
AutoCAD SHX Text
387 SF
AutoCAD SHX Text
AutoCAD SHX Text
636 SF
AutoCAD SHX Text
AutoCAD SHX Text
2,974 SF
AutoCAD SHX Text
AutoCAD SHX Text
8,224 SF
AutoCAD SHX Text
AutoCAD SHX Text N/A
AutoCAD SHX Text
SLEEPING UNIT SEPARATION - SMOKE PARTITIONS (PER NFPA 101 §26.3.5.1)
AutoCAD SHX Text
0 HR**
AutoCAD SHX Text
0 HR**
AutoCAD SHX Text
NON-SEPARATED MIXED USE
AutoCAD SHX Text
PER UFC 3-600-01 §4-34.3
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
LOW FREQUENCEY SOUNDER BASES REQUIRED?:
AutoCAD SHX Text
PER UFC 3-600-01 §4-34.3
AutoCAD SHX Text
PER UFC 3-600-01 §4-15.1
AutoCAD SHX Text
PER UFC 3-600-01 §9-17.1
AutoCAD SHX Text
PER UFC 3-600-01 §9-10.2
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
MASS NOTIFICATION SYSTEM REQUIRED?:
AutoCAD SHX Text
PER UFC 4-010-01
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
DRAWFORM REVISION: 7 AUGUST 2009
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
FOR COMMANDER NAVFAC / B.L.T.L.
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LIFE SAFETY - CODE CRITERIA - ACQ
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text 15135246
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
AutoCAD SHX Text
IPT SOUTHEAST
AutoCAD SHX Text
NAVAL AIR STATION JACKSONVILLE
AutoCAD SHX Text
NAS JRB NEW ORLEANS
AutoCAD SHX Text
NEW ORLEANS, LA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
M CONTESTABILE
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
JOANNE DIZ
AutoCAD SHX Text
CHIEF ENG/ARCH
AutoCAD SHX Text
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
ANTHONY DISANTO
AutoCAD SHX Text 1323108
N69450-XX-C-XXXX
ALTERNATE COMMAND POST
GENERAL FIRE PROTECTION REQUIREMENTS
BASIC BUILDING CODE INFORMATION
BUILDING & LIFE SAFETY CODE CRITERIA
BUILDING AREA
BUILDING HEIGHT AND NUMBER OF STORIES
BUILDING DESIGN OCCUPANT LOAD
FIRE RESISTANCE RATING OF BLDG ELEMENTS
LS002
B-3 SUBMITTAL
02/28/2020
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
E
A S
T
N O
R
TH
C O
M
C O
N S
TR
U
C T
A
LE
R T
FA
C
IL
IT
(PER NFPA TABLE 7.3.1.2)
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
TYPE:
AutoCAD SHX Text
(IBC 602)
AutoCAD SHX Text
DOES BUILDING HAVE ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
WHAT PERCENT OF STORY IS ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
DOES BUILDING REQUIRE INCIDENTAL USE AREA SEPARATION?:
AutoCAD SHX Text
MIXED OCCUPANCIES?:
AutoCAD SHX Text
OCCUPANCY GROUP:
AutoCAD SHX Text
NON SEPARATED?:
AutoCAD SHX Text
SEPARATED?:
AutoCAD SHX Text TYPE IIB UNPROTECTED, NONSPRINKLERED, EXTERIOR WALLS OF NON-COMBUSTIBLE MATERIALS
AutoCAD SHX Text BUSINESS GROUP B / BUSINESS (IBC 304.1, NFPA 101 §6.1.11.1)(IBC 304.1, NFPA 101 §6.1.11.1)
AutoCAD SHX Text N/A
AutoCAD SHX Text
AREA LIMIT (506.1) OF IBC:
AutoCAD SHX Text
TOTAL DESIGNED AREA OF BUILDING:
AutoCAD SHX Text
GROUP B (23,000 SQ. FT)
AutoCAD SHX Text
648 SF
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
SEPARATIONS
AutoCAD SHX Text
FIREBLOCKING REQUIRED?:
AutoCAD SHX Text
DRAFTSTOPPING REQUIRED?:
AutoCAD SHX Text
SMOKE CONTROL SYSTEM REQUIRED?:
AutoCAD SHX Text
SMOKE BARRIERS REQUIRED?:
AutoCAD SHX Text
SMOKE PARTITION REQUIRED?:
AutoCAD SHX Text
FIRE PARTITION REQUIRED?:
AutoCAD SHX Text
FIRE BARRIER REQUIRED?:
AutoCAD SHX Text
FIRE ALARM & DETECTION
AutoCAD SHX Text
FIRE ALARM & DETECTION SYSTEM REQUIRED?:
AutoCAD SHX Text
SUPPRESSION
AutoCAD SHX Text
STANDPIPES REQUIRED?:
AutoCAD SHX Text
SPRINKLERS REQUIRED?:
AutoCAD SHX Text
PORTABLE EXTINGUISHERS REQUIRED?:
AutoCAD SHX Text
HOOD SUPPRESSION SYSTEMS REQUIRED?:
AutoCAD SHX Text
STRUCTURAL FRAME (PER IBC TABLE 601)
AutoCAD SHX Text
BEARING WALLS
AutoCAD SHX Text
RATING AS REQUIRED (IN HOURS)
AutoCAD SHX Text
BUILDING ELEMENT
AutoCAD SHX Text
RATING AS DESIGNED (IN HOURS)
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
(PER IBC TABLE 601)
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
NONBEARING WALLS & PARTITIONS
AutoCAD SHX Text
(PER IBC TABLE 601 & 602)
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS (PER IBC TABLE 601)
AutoCAD SHX Text
ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS & JOISTS (PER IBC TABLE 601)
AutoCAD SHX Text
FIRE WALLS (PER IBC 706)
AutoCAD SHX Text
OCCUPANCY SEPARATION - FIRE BARRIERS (PER IBC 707)
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text
0 HR
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
MEANS OF EGRESS
AutoCAD SHX Text
EGRESS WIDTH (PER NFPA 101 TABLE 7.3.3.1)
AutoCAD SHX Text
CODE ITEM
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
APPLICABLE CODES
AutoCAD SHX Text
EXIT ACCESS TRAVEL DISTANCE BUSINESS (PER NFPA 101 PARAGRAPH 38.2.6.2)
AutoCAD SHX Text
REQUIRED (NONSPRINKLERED): 200 FEET PROPOSED: 27 FEET
AutoCAD SHX Text
DEAD END CORRIDOR BUSINESS (PER NFPA 101 38.2.5.2.2)
AutoCAD SHX Text
REQUIRED (NONSPRINKLERED): 20 FEET PROPOSED: NONE
AutoCAD SHX Text
COMMON PATH OF TRAVEL BUSINESS (PER NFPA 101 38.2.5.3.3)
AutoCAD SHX Text
REQUIRED (NONSPRINKLERED): 75 FEET PROPOSED: NONE
AutoCAD SHX Text
1. NUMBER OF EXITS:
AutoCAD SHX Text
a. GENERALLY TWO (2) FROM EVERY STORY FLOOR OR MEZZANINE (NFPA 101 §7.4.1.2). GENERALLY TWO (2) FROM EVERY STORY FLOOR OR MEZZANINE (NFPA 101 §7.4.1.2). b. A SINGLE MEANS OF EGRESS IS PERMITTED (NFPA 101 §38.2.4.4)A SINGLE MEANS OF EGRESS IS PERMITTED (NFPA 101 §38.2.4.4)
AutoCAD SHX Text
2. PROPOSED NUMBER OF EXITS:
AutoCAD SHX Text
a. TWO EXITS PROVIDED FROM BUILDING.TWO EXITS PROVIDED FROM BUILDING.
AutoCAD SHX Text UFC 3-600-01 DESIGN FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016, CHANGE 2, 25 MARCH 2018 INTERNATIONAL BUILDING CODE (IBC) 2015 FOR FIRE RESISTANCE REQUIREMENTS AND AREA LIMITATIONS AS REFERENCED BY UFC 3-600-01, PARAGRAPH 3-2 2015 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2016 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2016 NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES 2017 NFPA 70 NATIONAL ELECTRICAL CODES 2016 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 NFPA 80 STANDARD FOR FIRE DOOR AND OTHER OPENING PROTECTIVES 2015 NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS 2015 NFPA 101 LIFE SAFETY CODE, UFC 4-021-01, MASS NOTIFICATION SYSTEMS, 9 APRIL 2008, CHANGE 1, JANUARY 2010
AutoCAD SHX Text
HEIGHT LIMIT (504.3) AND NUMBER OF STORIES LIMIT (504.4) OF IBC:
AutoCAD SHX Text
55 FT / 3 STORIES
AutoCAD SHX Text 7 OCCUPANTS / 2 EXITS = 4 OCCUPANTS / EXIT TOTAL REQUIRED EXIT CAPACITY (NORMALLY OCCUPIED AREAS): 7 OCCUPANTS X 0.2”/OCCUPANT = 1.4” /OCCUPANT = 1.4” TOTAL PROVIDED EXIT CAPACITY (NORMALLY OCCUPIED AREAS): 68” (2 SETS OF SINGLE DOORS @ 34” EACH)EACH)
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
CONSTRUCTION CLASSIFICATION
AutoCAD SHX Text
TOTAL DESIGNED HEIGHT OF BUILDING AND NUMBER OF STORIES:
AutoCAD SHX Text
< 55 FT / 1 STORY55 FT / 1 STORY
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
USE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
ALLOWED PER
AutoCAD SHX Text
OCCUPANT
AutoCAD SHX Text
OCCUPANCY
AutoCAD SHX Text
LOAD
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
BUSINESS
AutoCAD SHX Text
648 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAND TOTAL
AutoCAD SHX Text
648 SF
AutoCAD SHX Text
AutoCAD SHX Text N/A
AutoCAD SHX Text
SINGLE OCCUPANCY
AutoCAD SHX Text
PER UFC 3-600-01 §9-17.1
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
MASS NOTIFICATION SYSTEM REQUIRED?:
AutoCAD SHX Text
3. EXIT REMOTENESS
AutoCAD SHX Text
a. ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION (NFPA 101 §7.5.1.3.2).ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION (NFPA 101 §7.5.1.3.2).
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
DRAWFORM REVISION: 7 AUGUST 2009
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
FOR COMMANDER NAVFAC / B.L.T.L.
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LIFE SAFETY - CODE CRITERIA - ALT CP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 15135247
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SHEET FORMAT IS 22" X 34". IF PRINTED SHEET IS NOT 22" X 34", THEN IT IS NOT TO SCALE
AutoCAD SHX Text
IPT SOUTHEAST
AutoCAD SHX Text
NAVAL AIR STATION JACKSONVILLE
AutoCAD SHX Text
NAS JRB NEW ORLEANS
AutoCAD SHX Text
NEW ORLEANS, LA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
M CONTESTABILE
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
JOANNE DIZ
AutoCAD SHX Text
CHIEF ENG/ARCH
AutoCAD SHX Text
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
ANTHONY DISANTO
AutoCAD SHX Text 1323108
SHELTER #1
GENERAL FIRE PROTECTION REQUIREMENTS
BASIC BUILDING CODE INFORMATION
BUILDING & LIFE SAFETY CODE CRITERIA
BUILDING AREA
BUILDING HEIGHT AND NUMBER OF STORIES
BUILDING DESIGN OCCUPANT LOAD
FIRE RESISTANCE RATING OF BLDG ELEMENTS
B-3 SUBMITTAL
02/28/2020
LS003
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
E
A S
T
N O
R
TH
C O
M
C O
N S
TR
U
C T
A
LE
R T
FA
C
IL
IT
(PER UFC 3-600-01 TABLE 10.1)
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
TYPE:
AutoCAD SHX Text
(IBC 602)
AutoCAD SHX Text
DOES BUILDING HAVE ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
WHAT PERCENT OF STORY IS ACCESSORY OCCUPANCY?:
AutoCAD SHX Text
DOES BUILDING REQUIRE INCIDENTAL USE AREA SEPARATION?:
AutoCAD SHX Text
MIXED OCCUPANCIES?:
AutoCAD SHX Text
OCCUPANCY GROUP:
AutoCAD SHX Text
NON SEPARATED?:
AutoCAD SHX Text
SEPARATED?:
AutoCAD SHX Text TYPE IIB UNPROTECTED, NONSPRINKLERED, EXTERIOR WALLS OF NON-COMBUSTIBLE MATERIALS
AutoCAD SHX Text MODERATE-HAZARD STORAGE GROUP S-1 / STORAGE (IBC 311.1, NFPA 101 §6.1.13.1)(IBC 311.1, NFPA 101 §6.1.13.1)
AutoCAD SHX Text N/A
AutoCAD SHX Text
AREA LIMIT (506.1) OF IBC:
AutoCAD SHX Text
TOTAL DESIGNED AREA OF BUILDING:
AutoCAD SHX Text
GROUP S-1 (17,500 SQ. FT)
AutoCAD SHX Text
13,388 SF
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
NO
AutoCAD SHX Text
YES
AutoCAD SHX Text
SEPARATIONS
AutoCAD SHX Text
FIREBLOCKING REQUIRED?:
AutoCAD SHX Text
DRAFTSTOPPING REQUIRED?:
AutoCAD SHX Text
SMOKE CONTROL SYSTEM REQUIRED?:
AutoCAD SHX Text
SMOKE BARRIERS REQUIRED?:
AutoCAD SHX Text
SMOKE PARTITION REQUIRED?:
AutoCAD SHX Text
FIRE PARTITION REQUIRED?:
AutoCAD SHX Text
FIRE BARRIER REQUIRED?:
AutoCAD SHX Text
FIRE ALARM & DETECTION
AutoCAD SHX Text
PER UFC 4-211-01 §3-6.19
AutoCAD SHX Text
FIRE ALARM & DETECTION SYSTEM REQUIRED?:
AutoCAD SHX Text
SUPPRESSION
AutoCAD SHX Text
STANDPIPES REQUIRED?:
AutoCAD SHX Text
SPRINKLERS…