This document summarizes a Request for Proposal (RFP) for the renovation and expansion of a domiciliary at the Hampton VA Medical Center located in Hampton, Virginia. The RFP seeks construction services with a magnitude between $5-10 million. It is a 100% SDVOSB set-aside issued by the Department of Veterans Affairs Veterans Health Administration VISN 6. Interested contractors must be registered in Vendor Information Pages and attend a mandatory pre-proposal site visit on August 18, 2020. Requests for information are due by August 21, 2020 with answers provided via amendment by August 28, 2020. Proposals are due September 21, 2020. The RFP includes scope of work, specifications and attachment details.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOWMAN FOSTER
& ASSOCIATES, INC
CONSULTING ENGINEERS 6353 Center Drive, Suite 101 Norfolk, VA 23502 (757) 466-7400
RENOVATE AND EXPAND
DOMICILIARY BUILDING 148
DEPARTMENT OF VETERANS AFFAIRS
HAMPTON, VA
HAZMAT REPORT
FINAL (CD) SUBMITTAL
July 26, 2019
BFA Project No. 13-025M VA Project No. 590-602
BOWMAN FOSTER WWW.BFA-ENG.COM SINCE 1961
Renovate and Expand Domiciliary Building 148 VA Medical Center Hampton, Virginia
GER 130-7212
Prepared for
Bowman, Foster & Associates, PC 6379 Center Drive
Norfolk, Virginia
Prepared by Matthew J. Rille
Virginia Asbestos Inspector # 3303003408
REPORT OF
HAZARDOUS MATERIALS
CONSULTING SERVICES
Southern Professional Center 1 2712 Southern Boulevard, Suite 101 Virginia Beach, Virginia 23452
(757) 463-3200 Fax (757) 463-3080 E-mail germail@geronline.com
May 8, 2017
Bowman, Foster & Associates, PC 6379 Center Drive Norfolk, VA 23502
Attention: Mr. Mike Dixon
Subject: Hazardous Materials Consulting Services Renovate and Expand Domiciliary Building 148 VA Medical Center Hampton, Virginia
GER 130-7212
GeoEnvironmental Resources, Inc. has completed our hazardous materials sampling of the subject facility. This work was completed in accordance with the scope of work and fee outlined in our proposal P16-130-6558 dated 18 October 2016. This report is relevant to the date of our field work and should not be relied upon for later dates.
We appreciate the opportunity of completing this work for Bowman, Foster & Associates. If there are any questions concerning this report, please contact us.
Sincerely, GeoEnvironmental Resources, Inc.
Matthew J. Rille Brian T. Hyde Industrial Hygienist Hazardous Materials Project Manager Virginia Asbestos Inspector (#3303003408) Virginia Asbestos Inspector (#3303002709)
Attachments: (1) Hazardous Materials Report
(2) Laboratory Reports
(3) Sample Location Maps
(4) Photographs
(5) Licenses
Southern Professional Center I 2712 Southern Boulevard, Suite 101 Virginia Beach, Virginia 23452
(757) 463-3200 Fax (757) 463-3080 E-mail germail@geronline.com
TABLE OF CONTENTS
Section 2 Bulk Sample Results/
Laboratory Sheets
Section 1 Report
Section 3 Sample Location Maps
Section 4 Photographic Documentation
Section 5 Licenses
ACRONYMS
AAS Atomic absorption spectroscopy ACBM Asbestos-containing building materials ACM Asbestos-containing materials ACT Acoustical ceiling tile ADA Americans with Disability Act AHERA Asbestos Hazard Emergency Response Act ASHARA Asbestos Schools Hazard Abatement Reauthorization Act ASTM American Society of Testing and Materials CMU Cement masonry unit CFC Chlorofluoro carbons CHMM Certified Hazardous Materials Manager CFR Code of Federal Regulation CSP Certified Safety Professional DEHP Di (2-ethylhexyl) phthalate DRO Diesel Range Organics ECD Electron capture detectors EA Each EPA U.S. Environmental Protection Agency GC Gas chromatography GRO Gasoline Range Organics GWB Gypsum wall board HBM Hazardous building material HID High intensity discharge HM Homogeneous material HUD U.S. Housing and Urban Development LBP Lead-based paint LF Linear feet LS Lump sum MDL Minimum detection limit mg/cm2 Milligrams per square centimeter mg/kg Milligrams per kilogram mg/L Milligrams per Liter ND none detected NVLAP National Voluntary Laboratory Accreditation Program OSHA Occupational Safety and Health Administration PCB Polychlorinated biphenyl PLM Polarized light microscopy ppm Parts per million RCRA Resource Conservation and Recovery Act SAP Sample and Analysis Plan SF Square Feet TCLP Toxicity characteristic leaching procedure TPH Total Petroleum Hydrocarbons TSI Thermal System Insulation VAC Virginia Administration Code VOC Volatile Organic Compound XRF X-Ray Fluorescence
Building 148 GER 130-7212 Page 1
PROJECT DESCRIPTION
The project will consist of the replacement of the HVAC system and the construction of two additions at Building 148 at the VA Medical Center in Hampton, Virginia. As part of this renovation the flat roofs will be replaced. Existing HVAC systems will be replaces. The two additions will increase the square footage of the Fitness Center and Library.
Building 148 was constructed in the mid 1980s. It is a steel and wood framed building with exterior brick walls, flat built-up asphalt roof with a mansard, and a slab-on-grade foundation. Typical interior finishes consists of vinyl floor tile, carpet, ceramic tile, drywall, plaster, and suspended acoustical ceiling tiles.
Our scope of work was to collect bulk samples of suspect asbestos-containing materials (ACM) and paint chip samples to determine lead, cadmium and chromium concentrations. We also inspected existing lighting fixtures for PCB-containing ballasts.
Bulk ACM samples were collected of visibly accessible materials expected to be disturbed by the demolition work. We are not aware of previous asbestos sampling or environmental reports concerning this facility.
SAMPLING METHODOLOGIES
SUSPECT ASBESTOS-CONTAINING MATERIALS
(ACM)
The AHERA regulation, 40 Code of Federal Regulations (CFR) 763, is the primary governing regulation when performing asbestos surveys. This regulation was originally enacted for school buildings, but has since been applied to public and commercial buildings by the Asbestos School Hazard Abatement Reauthorization Act (ASHARA) in 1994 and by the Occupational Safety and Health Administration’s (OSHA) worker protection regulations in 1995, specifically 29 CFR 1926.1101(k). The demolition of structures is also subject to 40 CFR Part 61 “National Emission Standards for Hazardous Air Pollutants” (NESHAPs).
ACM is specifically addressed in 40 CFR 61 Subpart M “National Emission Standard for Asbestos.”
ACM is generally divided into three primary classifications as follows: (a) Surfacing material, (b) Thermal System Insulation, and (c) Miscellaneous material. These classifications are defined in 40 CFR 763.83 as provided below.
Miscellaneous material means interior building on structural components, structural members or fixtures, such as floor and ceiling tiles, and does not include surfacing material or thermal system insulation.
Surfacing material means material in a school building that is sprayed-on, troweled-on, or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members, or other materials on surfaces for acoustical, fireproofing, or other purposes.
Thermal system insulation means material in a school building applied to pipes, fittings, boilers, breeching, tanks, ducts, or other interior structural components to prevent heat loss or gain, or water condensation, or for other purposes.
The sampling methodologies employed to address the ACM categories described above are as follows:
Surfacing material – An accredited inspector shall collect, in a statistically random manner that is representative of the homogeneous are, bulk samples from each homogeneous area of friable surfacing material that is not assumed to be ACM, and shall collect the samples as follows:
(1) At least three bulk samples shall be collected from each homogeneous area that is 1,000 SF or less.
(2) At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 SF but less than or equal to 5,000 SF.
GER
Report of Hazardous Materials Study Renovate and Expand Domiciliary Building 148
VA Medical Center Hampton, Virginia
GER 130-7212
(3) At least seven bulk samples shall be collected from each homogeneous area that is greater than 5,000 SF.
Thermal system insulation - An accredited inspector shall collect the samples as follows:
(1) At least three bulk samples, in a random distributed manner from each homogeneous area of thermal system insulation that is not assumed to be ACM.
(2) Collect at least one bulk sample from each homogeneous are of patched thermal system insulation that is not assumed to be ACM if the patched section is less than 6 linear or square feet.
(3) In a manner sufficient to determine whether the material is ACM or not ACM, collect bulk samples from each insulated mechanical system that is not assumed to be ACM where cement or plaster is used on fittings such as tees, elbows, or valves.
(4) Bulk samples are not required to be collected from any homogeneous area where the accredited inspector has determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACBM.
Miscellaneous material - An accredited inspector shall collect the samples as follows:
(1) In a manner sufficient to determine whether material is ACM or not ACM from each homogeneous area of friable miscellaneous material that is not assumed to be ACM.
Non friable suspected ACBM - An accredited inspector shall collect the samples as follows:
If any homogeneous area of non friable suspected ACBM is not assumed to be ACM, then an accredited inspector shall collect, in a manner sufficient to determine whether the material is ACM or not ACM, bulk samples from the homogeneous are of non friable suspected ACBM that is not assumed to be ACM.
LEAD BASED PAINT (LBP)
Testing of painted surfaces for lead, cadmium and chromium was conducted by collecting bulk paint chip samples from various painted surfaces. It is important to note that this inspection was not intended to meet the requirements of HUD sampling protocols for lead paint and was not a comprehensive, surface-by-surface evaluation, but rather a screening inspection of major painted components, which may contain LBP.
ANALYTICAL METHODS
SUSPECT ASBESTOS-CONTAINING MATERIALS
(ACM)
Suspect bulk ACM samples were analyzed using polarized light microscopy (PLM) and dispersion staining techniques. The analytical method was conducted in accordance with Method EPA-600/M4-82-020 and/or EPA 600/R-93/116.
Analysis was performed by EMSL Analytical, Inc., Cinnaminson, NJ NVLAP Lab Code 101048-0, AIHA-LAP, LLC-IHLAP Lab 100194, NYS ELAP
10872, NJ DEP 03036.
LEAD BASED PAINT (LBP)
Paint chip samples were analyzed for lead using inductively coupled plasma (ICP) emission spectroscopy (SW-846, 6010C). Analysis was performed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: 10896, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01.
ASBESTOS BULK SAMPLING
In April of 2017, seventy (70) bulk samples of suspect ACM were collected by Matthew J. Rille and Bryan T. Hyde, Virginia Licensed Asbestos Inspectors. Samples were collected from accessible areas that would be impacted by the planned renovations.
Typical suspect ACM included floor tile, drop ceiling tile, drywall/joint compound, plaster, base cove, roofing materials, sealants/caulks, and mastics.
All pipe insulation observed was fiberglass with paper insulation.
The attached Table 1 is a summary of the sample materials, sample location, and laboratory results.
Laboratory results are contained in Section 2 of this report. Drawings showing the approximate sample locations, are contained in Section 3.
Destructive activities such as breaking into walls, chases, ceilings, or floors were not performed in order to obtain samples. Therefore, if during the
Building 148 GER 130-7212 Page 3
GER
renovation process suspect hazardous materials are uncovered, they must be properly addressed.
As the sample results indicate, the following materials were determined to contain asbestos:
Roof Flashings Pitch Pockets
ASBESTOS DISCUSSION
The EPA defines ACM as any material which contains greater than 1% asbestos by weight. The following categories of ACM were identified in the renovation areas in Building 148:
Non-Friable ACM
Roof Flashings (6 - 10% Chrysotile): Found on the flat roofs of all the pods. All flashings are ACM. This material is classified as Category I ACM and was in good condition at the time of our survey. (Estimated Quantity - 3,441 square feet)
Pitch Pocket (10% Chrysotile): Found on the flat roof of the middle support pod. This material is classified as Category I ACM and was in good condition at the time of the survey. (Estimated Quantity - 1 EA)
All Asbestos-Containing Materials must be removed prior disturbance due to renovation. Therefore the roof flashings and pitch pocket must be removed by a Virginia licensed asbestos abatement contractor prior to disturbance due to renovation.
All asbestos abatement work shall be performed in accordance with local, state and Federal regulations including but not limited to:
29CFR1926.1101 - Asbestos
40CFR61 - National Emission Standards for Hazardous Air Pollutants
9VAC 20-81 - Virginia Solid Waste Management Regulations
18VAC 15-20 - Virginia Asbestos Licensing Regulations
PAINT SAMPLING
Three paint chip samples were collected by GER.
The attached Table 2 summarizes the samples collected and their laboratory results. The laboratory analytical results are contained in Section 2. The purpose of our sampling was to obtain representative data on the concentrations of lead, cadmium and chromium in the existing painted surfaces scheduled to be disturbed by the work. Paint samples were collected from painted surfaces that may be disturbed by the planned renovation work.
PAINT DISCUSSION
There are two frequently used standards to define lead-based paint, the Consumer Product and Safety Commission (CPSC) and the Department of Housing and Urban Development (HUD). In 1978, the CPSC, acting under the authority of the Consumer Product Safety Act, banned the sale of paint containing more than 0.06% lead by weight to consumers. Paint which contains more than 0.06% lead by weight is defined as Lead-containing paint (LCP). The Department of Housing and Urban Development (HUD) defines Lead-based paint (LBP) as any paint, varnish, shellac, or other coating that contains lead equal to or greater than
1.0 mg/cm2 as measured by X-ray fluorescence (XRF) analyzer or laboratory analysis, or 0.5% by weight as measured by laboratory analysis.
The Occupational Safety and Health Administration (OSHA) Lead in Construction Standard (29 CFR 1926.62) does not define lead-based paint.
However, to comply with OSHA, all painted surfaces with a lead concentration at or above the laboratory’s minimum detection limit (MDL) should be considered lead containing. Compliance with this standard is required even for paints with less than 0.5% or 0.06% lead by weight. Therefore, painted surfaces exceeding the MDL should not be disturbed without taking the appropriate precautions when performing certain high risk tasks. Activities such as scraping, sanding, welding/torching and disturbance of painted surfaces could potentially release leaded dust. OSHA has categorized the following high risks tasks into three groups:
Group 1: manual demolition manual scraping heat-gun applications power tool cleaning with dust collection system spray paint with lead-based paints
Group 2: lead burning using lead-containing mortar power tool cleaning without dust collection system
Building 148 GER 130-7212 Page 4 rivet blasting cleanup activities where dry expendable abrasives are used movement and removal of abrasive blasting enclosures
Group 3: abrasive blasting welding, cutting and burning on steel structures
Analytical results for lead paint indicated that all three of the samples collected and analyzed were found to have lead concentrations above the laboratory's MDL.
Paints containing cadmium and chromium are often found as protective coatings on structural steel or exterior coatings on metal surfaces. These paints tend to be red, yellow or orange and are typically the first layer. All of the bulk paint chip samples were also tested for cadmium and chromium.
Analytical results for cadmium indicated that one out of the three samples analyzed resulted in concentrations above the MDL.
Analytical results for chromium indicated that all of the samples analyzed resulted in concentrations above the MDL.
The National Institute for Occupational Safety and Health (NIOSH) identifies chromium as a confirmed carcinogen and cadmium as a suspect carcinogen.
Therefore, all existing painted surfaces scheduled for demolition should be considered lead, cadmium and chromium containing for the purposes of complying with 29 CFR 1926.62, 29 CFR 1926.1126 and 29 CFR 1926.1127 in order to protect workers and the environment.
Construction Standards established by OSHA for lead, cadmium and chromium are:
Lead 29 CFR 1926.62 Cadmium 29 CFR 1926.1127 Chromium 29 CRF 1926.1126
The permissible exposure limits (PEL) established by OSHA are 5 ug/m3 for cadmium, 5 ug/m3 for chromium (chromates) and 50 ug/m3 for lead.
The PEL is an airborne measurement to address worker exposure. There is no direct correlation between lead, cadmium, and chromium concentrations in paint and worker exposure. Only when these concentrations are below the laboratory’s MDL, is worker exposure not an issue.
Appropriate precautions should be taken during the disturbance of all painted surfaces to ensure protection of workers and the environment.
All lead, cadmium and chromium paint work shall be performed in accordance with all local, state and Federal regulations to protect workers and the environment, including but not limited to:
29CFR 1926.62 - Lead
29CFR 1926.1126 - Chromium
29CFR 1926.1127 - Cadmium
9VAC 20-60 - Virginia Hazardous Waste Management Regulations
9VAC 20-81 - Virginia Solid Waste Management Regulations
18VAC 15-30 - Virginia Lead-Based Paint Activity Regulations
POLYCHLORINATED BIPHENYLS (PCBS)
On January 1, 1979, the Environmental Protection Agency (EPA) banned the manufacturing of light ballasts which contain PCB’s and phased out most PCB uses. Therefore, all light ballasts manufactured prior to January 1, 1979 without “Non-PCB” markings must be considered PCB containing. The EPA’s actions subjects all substances containing over 50 ppm PCBs to regulatory control (with the exception of PCB-contaminated waste oil which is prohibited at any level).
Our field investigation of light fixtures indicated that existing fluorescent fixtures were T-8s, which use electronic ballast. Electronic ballast do not use PCBs as a potting material. Any non-electronic Ballast not marked “No PCBs” must be considered to contain PCB’s. We recommend assuming that all light ballasts are non-PCB and all light tubes and lamps are assumed to be mercury containing.
All PCB work shall be performed in accordance with all local, state and Federal regulations to protect workers and the environment, including but not limited to:
40CFR761 - Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution In Commerce, and Use Prohibitions
9VAC 20-80 - Virginia Solid Waste Management Regulations
Building 148 GER 130-7212 Page 5
WASTE CLASSIFICATION FOR PAINTED
BUILDING COMPONENTS
Building components and demolition waste streams which are painted must be properly characterized prior to disposal. The EPA Resource Conservation and Recovery Act (RCRA) regulations establish the limits for RCRA leachable metals (lead, cadmium, chromium, etc.). Leachable metals means the amount of metals likely to leach from the waste into the surrounding soil/groundwater system of a landfill. The leachable concentration of chemicals in a waste stream is determined by an analytical method called the toxicity characteristic leaching procedure (TCLP). Waste stream TCLP concentrations that equal or exceed the RCRA limits must be transported to a hazardous waste treatment, storage, or disposal facility. Precautions should be implemented to prevent the storage of any hazardous waste for more the 90 days. Specific permits are necessary to store hazardous waste in excess of 90 days.
LIMITATIONS
This report has been prepared for the exclusive use of Bowman, Foster & Associates and/or their agents. This service was performed in accordance with generally accepted environmental practices.
No other warranty, expressed or implied, is made.
Our conclusions and recommendations are based, in part, upon information provided to us by others and our site observations. We have not verified the completeness or accuracy of the information provided by others, unless otherwise noted. Our observations and recommendations are based upon conditions readily visible at the time of our site visit and upon current industry standards. During our inspection, accessible areas were visually inspected for the presence of asbestos and lead based paints.
The findings at these locations area assumed to be representative throughout the impacted areas of the building. Inaccessible areas were not visually inspected. Areas inspected for the above-referenced materials were limited to those designated by the client. The inspection did not include the entire building and was limited to the areas described in the report.
Under this scope of services, GER assumes no responsibility regarding response actions (e.g. O&M Plans, Remediation, Notifications, etc.) initiated as a result of these findings. GER assumes no liability for the duties and responsibilities of the Client with respect to compliance with local, state and Federal regulations. Compliance with regulations and response actions are the sole responsibility of the Client and should be conducted in accordance with local, state and Federal regulations and should be performed by appropriately licensed personnel, as warranted.
Building 148 GER 130-7212 Page 6
SECTION 2
Bulk Sample Results / Laboratory Analysis Sheets
Table 1 - Asbestos Sample Results
Table 2 - Paint Sample Results
Building 148 GER 130-7212
NO. SAMPLE LOCATION SAMPLE MATERIAL % & TYPE OF ASBESTOS
1 Library 12" Grey floor tile/mastic under carpet
None detected
2 Library 12" Grey floor tile/mastic under carpet
None detected
3 Library Black window sealant None detected
4 Library 4" Dark blue base cove/mastic None detected
5 Library Black window sealant None detected
6 Library 4" Dark blue base cove/mastic None detected
7 Library Spray applied fire proofing None detected
8 Library White mastic on fiberglass duct insulation
None detected
9 Library 2'x2' Ceiling tile None detected
10 Fitness Center Black window sealant None detected
11 Fitness Center 4" Tan base cove/mastic None detected
12 Fitness Center 4" Tan base cove/mastic None detected
13 Fitness Center Carpet mastic None detected
14 Fitness Center Carpet mastic None detected
15 Fitness Center Spray applied fire proofing None detected
16 Fitness Center 2'x2' Ceiling tile None detected
17 Waiting Room Joint compound None detected
18 Waiting Room Drywall None detected
19 Waiting Room Spray applied fire proofing None detected
20 Waiting Room Drywall None detected
21 Waiting Room Joint compound None detected
22 Room S103 Green epoxy flooring None detected
23 Room S102 Green epoxy flooring None detected
24 Room S122 Spray applied fire proofing None detected
25 Room S122 Joint compound None detected
26 Room S122 Drywall None detected
Table 1 - Asbestos Bulk Sample Results
Table 1 - Asbestos Bulk Sample Results
27 Room S122 White mastic on fiberglass duct insulation
None detected
28 Rec Room Sealant at radiator None detected
29 Vending Sealant at radiator None detected
30 Exterior, Fitness Center White window sealant None detected
31 Exterior, Fitness Center White window sealant None detected
32 Exterior, Fitness Center Plaster soffit None detected
33 Exterior, Fitness Center Plaster soffit None detected
34 Exterior, Library White window sealant None detected
35 No Sample No Sample None detected
36 Room A100, Bathroom Spray applied fire proofing None detected
37 Room A100, Bathroom 2'x2' Ceiling tile None detected
38 Room A100, Bathroom White mastic on fiberglass pipe insulation
None detected
39 Room A100, Bathroom Plaster wall None detected
40 Room A100 Drywall None detected
41 A Pod, Lounge White mastic on fiberglass duct insulation
None detected
42 A Pod, Lounge Joint compound None detected
43 A Pod, Hallway 2'x2' Ceiling tile None detected
44 Room B103, Bathroom Plaster wall None detected
45 Room B103, Bathroom White mastic on fiberglass pipe insulation
None detected
46 Room B103, Bathroom Spray applied fire proofing None detected
47 Room C100, Bathroom Plaster wall None detected
48 Hallway at Room C100 Sealant at radiator None detected
49 Room C129 12" Grey floor tile/mastic None detected
50 Room C129 4" Grey base cove/mastic None detected
51 B Pod, Hallway Sealant at radiator None detected
52 B Pod, Hallway Joint compound None detected
Table 1 - Asbestos Bulk Sample Results
53 Room B178 Drywall None detected
54 Hallway at Room D129 4" Grey base cove/mastic None detected
55 Electrical closet Red fire proofing sealant None detected
56 Electrical closet Red fire proofing sealant None detected
57 Mechanical Room White mastic on fiberglass pipe insulation
None detected
58 S Pod Roof Asphalt core None detected
59 S Pod Roof Curb flashing 8% Chrysotile
60 S Pod Roof Base flashing 10% Chrysotile
61 S Pod Roof Asphalt core None detected
62 S Pod Roof Pitch pocket 10% Chrysotile
63 S Pod Roof Sealant on counter flashing None detected
64 A Pod Roof Asphalt core None detected
65 A Pod Roof Base flashing 6% Chrysotile
66 A Pod Roof Sealant on counter flashing None detected
67 B Pod Roof Asphalt core None detected
68 B Pod Roof Base flashing None detected
69 C Pod Roof Asphalt core None detected
70 C Pod Roof Base flashing 6% Chrysotile
Table 2: Paint Chip Sample Results
Note: Highlighted blocks indicate concentrations above the laboratory’s reporting limit Note: Bold number indicates lead based paint (>0.5%)
Building 148 GER 130-7212
XXX0.0200.000130.27TanMechanical Room, metal door frameP3
XX0.015<0.0000980.14GreyRoom C129, metal door frameP2
XX0.0028<0.000110.024GreyRoom S122, metal door frameP1
ChromiumCadmiumLead
> MDL%
CHROMIUM
CADMIUM% LEADCOLORSAMPLE LOCATIONNO
EMSL Analytical, Inc.
200 Route 130 North Cinnaminson, NJ 08077
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710151EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Attention: Phone:Matthew Rille (757) 463-3200
Fax:GeoEnvironmental Resources (757) 463-3080
Received Date:2712 Southern Blvd. 04/12/2017 11:15 AM
Analysis Date:Suite 101 04/18/2017
Collected Date:Virginia Beach, VA 23452
Project: 1307212, Building 148 VAMC
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
130-148-1-Floor Tile
041710151-0001
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Library - 12" Grey
Floor Tile
130-148-1-Mastic
041710151-0001A
None DetectedNon-fibrous (Other)100%Black/Yellow
Non-Fibrous
Homogeneous
Library - Mastic
130-148-2-Floor Tile
041710151-0002
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Library - 12" Grey
Floor Tile
130-148-2-Mastic
041710151-0002A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Library - Mastic
130-148-3
041710151-0003
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Library - Black
Window Sealant
130-148-4-Base Cove
041710151-0004
None DetectedNon-fibrous (Other)100%Blue
Non-Fibrous
Homogeneous
Library - 4" Dark Blue
Base Cove
130-148-4-Mastic
041710151-0004A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Library - Mastic
130-148-5
041710151-0005
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Library - Black
Window Sealant
130-148-6-Base Cove
041710151-0006
None DetectedNon-fibrous (Other)100%Blue
Non-Fibrous
Homogeneous
Library - 4" Dark Blue
Base Cove
130-148-6-Mastic
041710151-0006A
None DetectedNon-fibrous (Other)100%Brown/White
Non-Fibrous
Homogeneous
Library - Mastic
130-148-7
041710151-0007
None DetectedNon-fibrous (Other)20%Min. Wool80%Gray
Fibrous
Homogeneous
Library - Spray
Applied Fireproofing
130-148-8
041710151-0008
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Library - White Mastic on Fiberglass Duct
Insulation
130-148-9
041710151-0009
None DetectedNon-fibrous (Other)20%Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
Library - 2'x2' Ceiling
Tile
130-148-10
041710151-0010
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Fitness Center - Black
Window Sealant
130-148-11-Base Cove
041710151-0011
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Fitness Center - 4"
Tan Base Cove
130-148-11-Mastic
041710151-0011A
None DetectedNon-fibrous (Other)100%Black/Yellow
Non-Fibrous
Homogeneous
Fitness Center -
Mastic
Initial report from: 04/18/2017 15:39:10
Page 1 of 4ASB_PLM_0008_0001 - 1.78 Printed: 4/18/2017 3:39 PM
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710151EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
130-148-12-Base Cove
041710151-0012
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Fitness Center - 4"
Tan Base Cove
130-148-12-Mastic
041710151-0012A
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
Fitness Center -
Mastic
130-148-13
041710151-0013
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Fitness Center -
Carpet Mastic
130-148-14
041710151-0014
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Fitness Center -
Carpet Mastic
130-148-15
041710151-0015
None DetectedNon-fibrous (Other)20%Min. Wool80%Gray
Fibrous
Homogeneous
Fitness Center -
Spray Applied
Fireproofing
130-148-16
041710151-0016
None DetectedNon-fibrous (Other)20%Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
Fitness Center - 2'x2'
Ceiling Tile
130-148-17
041710151-0017
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Waiting Room - Joint
Compound
130-148-18
041710151-0018
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White
Fibrous
Homogeneous
Waiting Room -
Drywall
130-148-19
041710151-0019
None DetectedNon-fibrous (Other)30%Min. Wool70%Gray
Fibrous
Homogeneous
Waiting Room - Spray
Applied Fireproofing
130-148-20
041710151-0020
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White
Fibrous
Homogeneous
Waiting Room -
Drywall
130-148-21
041710151-0021
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Waiting Room - Joint
Compound
130-148-22
041710151-0022
None DetectedNon-fibrous (Other)100%Green
Non-Fibrous
Homogeneous
Room S103 - Green
Epoxy Flooring
130-148-23
041710151-0023
None DetectedNon-fibrous (Other)100%Gray/Green
Non-Fibrous
Homogeneous
Room S102 - Green
Epoxy Flooring
130-148-24
041710151-0024
None DetectedNon-fibrous (Other)20%Min. Wool80%Gray
Fibrous
Homogeneous
Room S122 - Spray
Applied Fireproofing
130-148-25
041710151-0025
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room S122 - Joint
Compound
130-148-26
041710151-0026
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White
Fibrous
Homogeneous
Room S122 - Drywall
130-148-27
041710151-0027
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room S122 - White
Mastic on Fiberglass
Duct Insulation
130-148-28
041710151-0028
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Rec Room - Sealant at Radiator
130-148-29
041710151-0029
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Vending - Sealant at
Radiator
Page 2 of 4ASB_PLM_0008_0001 - 1.78 Printed: 4/18/2017 3:39 PM
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710151EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
130-148-30
041710151-0030
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior - Fitness
Center - White
Window Sealant
130-148-31
041710151-0031
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Exterior - Fitness
Center - White
Window Sealant
130-148-32
041710151-0032
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior - Fitness
Center - Plaster Soffit
130-148-33
041710151-0033
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior - Fitness
Center - Plaster Soffit
130-148-34
041710151-0034
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior Library -
White Window
Sealant
130-148-36
041710151-0035
None DetectedNon-fibrous (Other)20%Min. Wool80%Gray
Fibrous
Homogeneous
Room A100 -
Bathroom - Spray
Applied Fireproofing
130-148-37
041710151-0036
None DetectedNon-fibrous (Other)20%Cellulose
Min. Wool
50%
30%
Brown/White
Fibrous
Homogeneous
Room A100 -
Bathroom - 2'x2'
Ceiling Tile
130-148-38
041710151-0037
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room A100 -
Bathroom - White
Mastic on Fiberglass
Pipe Insulation
130-148-39
041710151-0038
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room A100 -
Bathroom - Plaster
Wall
130-148-40
041710151-0039
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White
Fibrous
Homogeneous
Room A100 - Drywall
130-148-41
041710151-0040
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
A Pod - Lounge -
White Mastic on
Fiberglass Duct
Insulation
130-148-42
041710151-0041
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
A Pod - Lounge -
Joint Compound
130-148-43
041710151-0042
None DetectedNon-fibrous (Other)20%Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
A Pod - Hallway -
2'x2' Ceiling Tile
130-148-44
041710151-0043
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room B103 -
Bathroom - Plaster
Wall
130-148-45
041710151-0044
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Room B103 -
Bathroom - White
Mastic on Fiberglass
Pipe Insulation
130-148-46
041710151-0045
None DetectedNon-fibrous (Other)20%Min. Wool80%Gray
Fibrous
Homogeneous
Room B103 -
Bathroom - Spray
Applied Fireproofing
130-148-47
041710151-0046
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Room B103 -
Bathroom - Plaster
Wall
130-148-48
041710151-0047
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Hallway at Room
C100 - Sealant at
Radiator
Page 3 of 4ASB_PLM_0008_0001 - 1.78 Printed: 4/18/2017 3:39 PM
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710151EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
130-148-49-Floor Tile
041710151-0048
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room C129 - 12"
Grey Floor Tile
130-148-49-Mastic
041710151-0048A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Room C129 - Mastic
130-148-50-Base Cove
041710151-0049
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Room C129 - 4" Grey
Base Cove
130-148-50-Mastic
041710151-0049A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Room C129 - Mastic
130-148-51
041710151-0050
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
B Pod - Hallway -
Sealant at Radiator
130-148-52
041710151-0051
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
B Pod - Hallway -
Joint Compound
130-148-53
041710151-0052
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White
Fibrous
Homogeneous
Room B178 - Drywall
130-148-54-Base Cove
041710151-0053
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Hallway at Room
D129 - 4" Grey Base
Cove
130-148-54-Mastic
041710151-0053A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Hallway at Room
D129 - Mastic
130-148-55
041710151-0054
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
Electrical Closet -
Red Fireproofing
Sealant
130-148-56
041710151-0055
None DetectedNon-fibrous (Other)95%Glass5%Red
Non-Fibrous
Homogeneous
Electrical Closet -
Red Fireproofing
Sealant
130-148-57
041710151-0056
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Mechanical Room -
White Mastic on
Fiberglass Pipe
Insulation
Analyst(s)
Daniel Fricker (13)
Rebecca Siegel (52)
Benjamin Ellis, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NVLAP Lab Code 101048-0, AIHA-LAP, LLC-IHLAP Lab 100194, NYS ELAP 10872, NJ DEP 03036, PA ID# 68-00367
Page 4 of 4ASB_PLM_0008_0001 - 1.78 Printed: 4/18/2017 3:39 PM
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710589EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Attention: Phone:Brian Hyde (757) 463-3200
Fax:GeoEnvironmental Resources (757) 463-3080
Received Date:2712 Southern Blvd. 04/17/2017 8:55 AM
Analysis Date:Suite 101 04/19/2017
Collected Date:Virginia Beach, VA 23452 04/14/2017
Project: 130-7212
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
58-Tar Felt
041710589-0001
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
S Roof - Asphalt Core
58-Tar
041710589-0001A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
S Roof - Asphalt Core
041710589-0002
8% ChrysotileNon-fibrous (Other)82%Cellulose10%Brown/Black
Fibrous
Homogeneous
S Roof - Curb
Flashing
60-Flashing
041710589-0003
10% ChrysotileNon-fibrous (Other)90%Black/Silver
Fibrous
Homogeneous
S Roof - Base
Flashing
60-Tar Felt
041710589-0003A
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
S Roof - Tar Felt
60-Tar
041710589-0003B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
S Roof - Tar
61-Tar Felt
041710589-0004
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
S Roof - Asphalt Core
61-Tar
041710589-0004A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
S Roof - Tar
041710589-0005
10% ChrysotileNon-fibrous (Other)90%Black
Non-Fibrous
Homogeneous
S Roof - Pitch Pocket
041710589-0006
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
S Roof - Sealant on
Counter Flashing
64-Tar Felt
041710589-0007
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
A Roof - Asphalt Core
64-Tar
041710589-0007A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
A Roof - Tar
65-Flashing
041710589-0008
6% ChrysotileNon-fibrous (Other)74%Glass20%Black/Silver
Fibrous
Homogeneous
A Roof - Base
Flashing
65-Tar Felt
041710589-0008A
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
A Roof - Tar Felt
65-Tar
041710589-0008B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
A Roof - Tar
041710589-0009
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
A Roof - Sealant on
Counter Flashing
Initial report from: 04/19/2017 09:51:13
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 4/19/2017 9:51 AM
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041710589EMSL Order:
Customer ID: GEOE25
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
67-Tar Felt
041710589-0010
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
B Roof - Asphalt Core
67-Tar
041710589-0010A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
B Roof - Tar
68-Flashing
041710589-0011
None DetectedNon-fibrous (Other)70%Glass30%White/Black
Fibrous
Homogeneous
B Roof - Base
Flashing
68-Tar Felt
041710589-0011A
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
B Roof - Tar Felt
68-Tar
041710589-0011B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
B Roof - Tar
69-Tar Felt
041710589-0012
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
C Roof - Asphalt Core
69-Tar
041710589-0012A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
C Roof - Tar
70-Flashing
041710589-0013
6% ChrysotileNon-fibrous (Other)74%Glass20%Black/Silver
Fibrous
Homogeneous
C Roof - Base
Flashing
70-Tar Felt
041710589-0013A
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
C Roof - Tar Felt
70-Tar
041710589-0013B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
C Roof - Tar
Analyst(s)
Benjamin Verghese (24)
Daniel Fricker (2)
Benjamin Ellis, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NVLAP Lab Code 101048-0, AIHA-LAP, LLC-IHLAP Lab 100194, NYS ELAP 10872, NJ DEP 03036, PA ID# 68-00367
Initial report from: 04/19/2017 09:51:13
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 4/19/2017 9:51 AM
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 858-4571 http://www.EMSL.com EnvChemistry2@emsl.com
011702781 CustomerID: GEOE25 CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Matthew Rille GeoEnvironmental Resources 2712 Southern Blvd.
Suite 101 Virginia Beach, VA 23452
Received: 04/12/17 11:15 AM
130-7212, Bldg. 148 VAMC
Fax: (757) 463-3080 Phone: (757) 463-3200
Project:
Client Sample Description Lab ID:P-1 011702781-0001 Room S122
Collected: 4/10/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3050B/6010C Cadmium BBND % wt 4/17/20170.00011 4/17/2017 LY
3050B/6010C Chromium BB0.0028 % wt 4/17/20170.00027 4/17/2017 LY
3050B/6010C Lead BB0.024 % wt 4/17/20170.00027 4/17/2017 LY
Client Sample Description Lab ID:P-2 011702781-0002 Room C129
Collected: 4/10/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3050B/6010C Cadmium BBND % wt 4/17/20170.000098 4/17/2017 LY
3050B/6010C Chromium BB0.015 % wt 4/17/20170.00025 4/17/2017 LY
3050B/6010C Lead BE0.14 % wt 4/18/20170.0012 4/17/2017 LY
Client Sample Description Lab ID:P-3 011702781-0003 Mech Room
Collected: 4/10/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3050B/6010C Cadmium BB0.00013 % wt 4/17/20170.00011 4/17/2017 LY
3050B/6010C Chromium BB0.020 % wt 4/17/20170.00028 4/17/2017 LY
3050B/6010C Lead BE0.27 % wt 4/18/20170.0028 4/17/2017 LY
ND - indicates that the analyte was not detected at the reporting limit RL - Reporting Limit (Analytical)
Definitions:
Page 2 of 2ChemSmplw/RDL/NELAC-7.44.3 Printed: 4/19/2017 4:08:37 PM http://www.EMSL.com mailto:EnvChemistry2@emsl.com
SECTION 3
Sample Location Maps
Sample Location PlanSample Location Plan
PROJECT:PROJECT:
DRAWING 1 OF 9DRAWING 1 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
UP
CORRIDOR
TO POD B
CORRIDOR
TO POD A
CORRIDOR
TO POD D
CORRIDOR
TO POD C
ELECTRICAL VAULT
MECHANICAL ROOM
EMERGENCY
GENERATOR
ROOM
STORAGE
STORAGE
EMS STORAGE
STORAGE
MAIN
TELEPHONE
CLOSET
ELECTRICAL
CLOSET
LOUNGE
CONFERENCE ROOM
GENERAL
STORAGE
E L E C
C L O S E T
OFFICE OFFICE
CHIEF
DOMICILLARY OFFICE
OFFICE
MAIN
ENTRANCE
RECREATION ROOM
VENDING
OFFICE
WAITING ROOM
DOMICILLARY
CARE
OFFICE/
RECEPTION
WAITING ROOM
PATIENT
SCREENING
STORAGE
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
H.A.C.
LIBRARY
FITNESS CENTER
GROUP ROOM
Pod “S” Floor Plan
3132 33
25 24
P3
P1
DRAWING 2 OF 9DRAWING 2 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “A” Floor Plan
CORRIDOR TO
SUPPORT FACILITY
DAP OFFICE
LUGGAGE
STORAGE
KITCHENETTE
LAUNDRY
OFFICE
OFFICE
ELECTRICAL
CLOSET
STOR
COMM
CLOSET
HAC
STOR
STOR
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STORAGE
PATIENT
ROOM
H&CC
OFFICE
H&CC
RECEPTION
H&CC
MANAGER
ROOF
ACCESS
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
NO CURE
PATIENT
ROOM
PATIENT
ROOM
DAP OFFICE
STORAGE
ELEC
CLOSET
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STOR
COMM
STOR
ROOF
ACCESS
LOUNGE
MED FOS HOME
OFFICE
SOILED LINEN
H&CC NURSE OFFICE
COURTYARD
42 43
DRAWING 3 OF 9DRAWING 3 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “B” Floor Plan
CORRIDOR TO
SUPPORT FACILITY
DAP OFFICE
LUGGAGE
STORAGE
KITCHENETTE
LAUNDRY
OFFICE
OFFICE
ELECTRICAL
CLOSET
STOR
COMM
CLOSET
HAC
STOR
STOR
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STORAGE
PATIENT
ROOM
H&CC
OFFICE
H&CC
RECEPTION
H&CC
MANAGER
ROOF
ACCESS
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
NO CURE
PATIENT
ROOM
PATIENT
ROOM
DAP OFFICE
STORAGE
ELEC
CLOSET
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STOR
COMM
STOR
ROOF
ACCESS
LOUNGE
MED FOS HOME
OFFICE
SOILED LINEN
H&CC NURSE OFFICE
COURTYARD
Samples collected in connecting corridor
DRAWING 4 OF 9DRAWING 4 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “C” Floor Plan
CORRIDOR TO
SUPPORT FACILITY
DAP OFFICE
LUGGAGE
STORAGE
KITCHENETTE
LAUNDRY
OFFICE
OFFICE
ELECTRICAL
CLOSET
STOR
COMM
CLOSET
HAC
STOR
STOR
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STORAGE
PATIENT
ROOM
H&CC
OFFICE
H&CC
RECEPTION
H&CC
MANAGER
ROOF
ACCESS
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
NO CURE
PATIENT
ROOM
PATIENT
ROOM
DAP OFFICE
STORAGE
ELEC
CLOSET
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STOR
COMM
STOR
ROOF
ACCESS
LOUNGE
MED FOS HOME
OFFICE
SOILED LINEN
H&CC NURSE OFFICE
COURTYARD
P2
DRAWING 5 OF 9DRAWING 5 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “D” Floor Plan
CORRIDOR TO
SUPPORT FACILITY
DAP OFFICE
LUGGAGE
STORAGE
KITCHENETTE
LAUNDRY
OFFICE
OFFICE
ELECTRICAL
CLOSET
STOR
COMM
CLOSET
HAC
STOR
STOR
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STORAGE
PATIENT
ROOM
H&CC
OFFICE
H&CC
RECEPTION
H&CC
MANAGER
ROOF
ACCESS
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
NO CURE
PATIENT
ROOM
PATIENT
ROOM
DAP OFFICE
STORAGE
ELEC
CLOSET
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
STOR
COMM
STOR
ROOF
ACCESS
LOUNGE
MED FOS HOME
OFFICE
SOILED LINEN
H&CC NURSE OFFICE
COURTYARD
DRAWING 6 OF 9DRAWING 6 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “S” Roof Plan
CORRIDOR
TO POD B
CORRIDOR
TO POD A
CORRIDOR
TO POD D
CORRIDOR
TO POD C
DRAWING 7 OF 9DRAWING 7 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “A” Roof Plan
CORRIDOR TO
SUPPORT FACILITY
COURTYARD
DRAWING 8 OF 9DRAWING 8 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON, VIRGINIA
130-7212
DATE:DATE:
SCALE:SCALE: NONE
APRIL 2017
NOTE - THE LOCATION FROM WHICH THE SAMPLES WERE OBTAINED SHOULD
NOT BE INTERPRETED AS THE ONLY LOCATION WHERE THE MATERIAL EXISTS.
POSITIVE SAMPLE LOCATION FOR ASBESTOS
NEGATIVE SAMPLE LOCATION FOR ASBESTOS
LEGEND
PAINT SAMPLE LOCATION
Pod “B” Roof Plan
CORRIDOR TO
SUPPORT FACILITY
COURTYARD
DRAWING 9 OF 9DRAWING 9 OF 9
NUMBER:NUMBER:RENOVATE AND EXPAND DOMICILIARY
BUILDING 148, VA MEDICAL CENTER
HAMPTON…