Attachment T - Shelter Layout 2 Room Shelter.pdf
PDF 161 KB Posted
- Attached to
- Cumberland Communications Facility
- Solicitation number
- BPM057831
- Issued by
- Allegany County, Maryland
About this file
This is a technical shelter layout attachment for the State of Maryland's Cumberland Communications Facility project in Allegany County, Maryland. The document presents a typical two-room shelter design measuring 12 feet by 38 feet, intended to house communications equipment and a generator. The layout is subject to the State's approval and includes dimensional specifications that are noted as approximate, with the final design configuration to be confirmed pending Maryland's authorization. The shelter accommodates the maximum number of equipment rows based on its length, and the document indicates multiple revision iterations dating from September 2008 through June 2009, reflecting design modifications including relocated 240VAC outlets and added alarm systems.
The attachment details the internal equipment configuration and electrical infrastructure required for the shelter installation. Key components specified include an Appleton door, exterior lighting, telco board with 24-inch cable ladders, vertical 240-volt twist-lock outlets, 120-volt quad box outlets, temperature-activated fans, light controllers with penetrations for SO cables, a pull box with 4-inch telco penetration, an automatic transfer switch, main and building subfeed disconnects, Type 2 MOV integrated load center, 16-port cable entry port, internal and external ground bus bars, telco cable ladder, HVAC system, rack footprint provisions, generator unit with exhaust system, generator annunciator panel, alarm system, and cable or hose bibs. The document serves as a reference standard for shelter construction and equipment placement to support the communications tower facility installation project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I h
I
I r
I ii d !1 :d
D b b
I : . [Il]] A
TTA
C
H M
EN
T "T"
TY
PIC
A
L TW
O R
O O
M
SH
ELTER
26'
DATE ORIGINAL
LATEST REVISION
SCALE
JOB NO.
REVISIONS
NO. DATE DESCRIPTION
DRAWNCHECKED
TITLE
R 1R
R 1R
R 1R
R 1R
R 2R
R 2R
R 2R
R 2R
R 3R
R 3R
R 3R
R 3R
R 4R
R 4R
R 4R
R 4R
A D oo r
B Ap pl et on P lu g
C Ex te rio r L ig ht D
4x
Te lc o bo ar d
E
" c ab le la dd er s F
St an d of fs fo r # gr ou nd le ad
G (3
) v er tic al ly m ou nt ed v ou tle ts
(tw is t l oc k ty pe
H
0V Q ua d bo x ou tle t I
IN
li gh ts
J In ta ke h oo d K
Te m p ac tiv at ed fa ns L
Li gh t c on tro lle r a nd p en et ra tio n fo r S
O ca bl es
M Pu ll bo x an d 4I
N p en et ra tio n fo r t el co
N Au to tr an sf er s w itc h O
M ai n se rv ic e di sc on ne ct
P Bu ild in g su bf ee d di sc on ne ct
Q Ty pe
M O
V R
In te gr at ed lo ad c en te r
S
P or t c ab le e nt ry p or t T
In te rn al g ro un d bu s ba r
U Ex te rn al g ro un d bu s ba r V
Q ua d bo x lo ad c en te r W
Te lc o ca bl e la dd er X
H
VA
C Y
R ac k fo ot pr in t
Z G en er at or
A A G en er at or e xh au st
A B A C A D A E A F A G A H A I A J
A
B C
A
E
FG
H I
J
J
J
K K
M
N
O P Q
R S
T
U
V W
XX
Y
Z
A A
L
D
S T
¼” : 1"
State of Maryland
Typical 12x38 Ft Shelter (with generator) Layout
9/8/08
-Dimensions are approximate.
-Final layout/design is subject to the State’s approval.
A B
Al ar m
Bl oc k
(n o en cl os ur e)
B 10/08 Added alarms
E
Y
C 06/09 Changed location of 240VAC outlets/ added r1/r3 120VAC
C
A C
Ap pl et on c ab le /h os e bi b
G en er at or a nu nc ia to r p an el
A D Sh el te r w ill ac co m od at e th e m ax im um n um be r of ro w s ba se d on it s eq ui pm en t r oo m le ng th
| Typical 2_Room Shelter |
| ATT T Shelter Layout 2 Room Shelter |
File details come from the government source that posted it. Updated .