This is a tower loading specification document for a communications monopole tower project in Cumberland, Maryland, submitted by the Maryland Department of Information Technology (DoIT). The document outlines the structural design requirements for a 185-foot monopole tower, specifying antenna mounting locations and configurations across multiple elevation levels. The design accommodates nine antenna systems distributed across the tower structure, including one lightning rod at 200 feet, three CC807-11 BOG6 antennas with collar mounts at the 180-165 foot elevation, two 6-foot HP Dish R5 antennas with collar mounts at the 150-145 foot level, and six WPA-700102-8CF-3-25-850 PSA6 antennas with collar mounts positioned at the 125-100 foot and 100-75 foot elevations. The design mandates that cables be routed inside the monopole with cable ports positioned below proposed antenna elevations to maintain structural integrity. The tower and foundation structure must incorporate 50 percent additional design capacity beyond calculated loads, and the document notes consideration for additional antennas in the structural design calculations.
The tower loading specification is part of a larger procurement package for the Cumberland Communications Facility, with proposals due August 21, 2026, at 12:00 PM via electronic submission through eMMA. A mandatory pre-proposal site visit was scheduled for July 16, 2026, at 11:00 AM at 600 Bishop Walsh Road, Cumberland, Maryland. The contract is subject to a 3 percent Minority Business Enterprise (MBE) subcontracting goal and Maryland prevailing wage requirements, as the contract value exceeds $500,000. The estimated period of performance spans 260 working days following Notice to Proceed, with liquidated damages assessed at $700 per day for delays beyond 180 business days. The contractor must provide $2,000,000 in commercial general liability insurance and $1,000,000 in performance and payment bonds within ten business days of recommended award, with 10 percent retainage withheld until final completion. Warranty coverage includes five years for tower materials and structures, and two years for equipment shelters, generators, and associated equipment.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
*Cables routed inside monopole
*Provide 50% additional capacity in the design of foundation and tower structure
*Place cable ports below the proposed antenna elevations.
Elevation Qty Antenna Mount Notes Qty Antenna Mount Notes
185 1 Lightning Rod n/a 4'
165 3 CC807-11 BOG6 with collar mount 1 TTA n/a mounted to BOG6
150 2 6' HP Dish R5 with collar mount
125 3 WPA-700102-8CF-3-25-850 PSA6 with collar mount
100 3 WPA-700102-8CF-3-25-850 PSA6 with collar mount
Ground
Note the additional antennas that should be considered in the design