This document is a technical specification for traffic signage (Section 10 14 53) that establishes standards for the design, fabrication, and installation of traffic signs and delineators for federal highway projects.

The specification addresses four primary product categories: traffic sign posts (steel flanged channel sections, perforated steel tubes, steel tubes, and structural steel H-sections), sign panels (flat and extruded aluminum), retroreflective sheeting for visibility, and delineator posts with retroreflectors. Traffic sign posts must conform to ASTM standards with minimum yield strengths of 30 ksi and tensile strengths of 50 ksi, and must be hot-dip galvanized per ASTM A123/A123M. Aluminum sign panels must meet ASTM B209/B221 specifications in alloys 6061-T6, 5052-H38, or 6063-T6. All retroreflective sheeting must comply with ASTM D4956 or AASHTO M 268 standards as Type III, IV, VII, VIII, IX, or XI with Class 1, 3, or 4 adhesive backing and must be high-intensity, unmetallized micro prismatic material. Delineator posts may be steel or flexible polymer/polycarbonate materials, with steel retroreflectors (3-inch minimum diameter) or retroreflective sheeting plates. Execution requirements mandate compliance with the Manual on Uniform Traffic Control Devices (MUTCD), vertical mounting at right angles to traffic direction, and inspection by the Contracting Officer's representative prior to acceptance. All work must reference specifications from AASHTO, ASTM International, AWPA, and the FHWA, with specific submission requirements for product data, FHWA acceptance letters, and sample approvals.

View the file

Other files

File Type Posted
Wage Determination NM20260035 (Dona Ana Highway) Eff. May 18 2026.pdf PDF
Attachment K - Site Clearance and Line Marking Permit.pdf PDF
Attachment A - The Army Radiation Permit ARP.pdf PDF
Statement of Work W911SG27BA002.pdf PDF
Attachment D - Contractor Requirements Document.pdf PDF
Attachment N - UFGS 05 52 00 Metal Railings.pdf PDF
Attachment N - UFGS 03 30 00 Cast-in-Place Concrete.pdf PDF
Attachment N - UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving.pdf PDF
Attachment I - iWATCH Training for Contractors.pdf PDF
Attachment N - UFGS 32 01 19.61 Sealing Cracks in Asphalt Paving.pdf PDF
Attachment H - Fire Prevention Construction Guide 2025.pdf PDF
Attachment N - UFGS 32 12 13 Bituminous Tack and Prime Coats.pdf PDF
Attachment L - NMDOT Spec.pdf PDF
Attachment N - UFGS 32 01 11.51 Rubber and Paint Removal -Airfield.pdf PDF
Attachment B - As-built Requirements.pdf PDF
Attachment F - DPW-RFI Template Blank Form.pdf PDF
Attachment E - DD1354 Form.pdf PDF
Attachment N - UFGS 32 12 15.13 Asphalt Paving for Airfields.pdf PDF
Attachment N - UFGS 32 93 00 Exterior Improvements Plants (1).pdf PDF
Attachment N - UFGS 31 00 00 Earthwork.pdf PDF
Attachment N - UFGS 34 71 13.16 Vehicle Crash Barriers.pdf PDF
Attachment N - UFGS 26 00 00 Electrical.pdf PDF
Attachment N - UFGS 32 01 13.62 Asphalt Surface Treatment.pdf PDF
Attachment N - UFGS 32 16 19 Concrete Curbs Gutters and Sidewalks.pdf PDF
Attachment J - SF 1413 Statement and Acknowledgement for Subcontractors.pdf PDF
Attachment N - UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads.pdf PDF
Attachment N - UFGS 02 41 00 Demolition.pdf PDF
Attachment N - UFGS 32 31 13 Chain Link Fences and gates.pdf PDF
Attachment N - UFGS 32 84 23 Underground Sprinkler Systems.pdf PDF
Attachment N - UFGS 32 01 16.75 Heater Scarifying of Asphalt Paving.pdf PDF
Attachment C - Construction and Demolition Sample Report.pdf PDF
Attachment N - UFGS 32 17 23 Pavement Markings.pdf PDF
Attachment G - DPW SUBMITTAL FORM V.1.pdf PDF
Attachment N - UFGS 32 12 16 Hot-Mix Asphalt HMA for Roads.pdf PDF
Wage Determination TX20260293 (El Paso Highway) Eff. May 18 2026.pdf PDF
Attachment N - UFGS 33 40 00 Storm Drainage Utilities.pdf PDF
Attachment N - UFGS 32 11 20 Base Course.pdf PDF
Wage Determination NM20260036 (Multiple NM Highway) Eff. May 18 2026.pdf PDF
Attachment N - UFGS 03 45 33 Precast Structural Concrete.pdf PDF
Attachment N - UFGS 31 11 00 Clearing and Grubbing.pdf PDF
Attachment L - TXDOT Spec.pdf PDF
Attachment N - UFGS 32 01 16.71 Cold Milling Asphalt Paving.pdf PDF
Attachment N - UFGS 32 11 33.13 Cement Stabilized Soil (1).pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 10 14 53 Page 1

SECTION TABLE OF CONTENTS DIVISION 10 - SPECIALTIES SECTION 10 14 53

TRAFFIC SIGNAGE

02/15

Table of Contents

PART 1 GENERAL

1.2 GENERAL

1.3 SUBMITTALS

PART 2 PRODUCTS

2.1 TRAFFIC SIGN POSTS

2.2 FLAT ALUMINUM SIGN PANELS

2.3 EXTRUDED ALUMINUM SIGN PANELS

2.4 TRAFFIC SIGN RETROREFLECTIVE SHEETING

2.5 LETTERS, NUMERALS, ARROWS, SYMBOLS, AND BORDERS

2.6 DELINEATOR POSTS

2.7 DELINEATOR RETROREFLECTORS

2.8 HARDWARE

2.9 CONCRETE

PART 3 EXECUTION

3.1 SIGN POSTS

3.2 SIGN PANELS

3.3 DELINEATORS

3.4 LOCATION AND POSITION OF SIGNS

SECTION 10 14 53 Page 2

PART 1 GENERAL.

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS

(AASHTO)

AASHTO M 133 (2012; R 2016) Standard Specification for

Preservatives and Pressure Treatment

Processes for Timber

AASHTO M 168 (2007; R 2012) Standard Specification for

Wood Products

AASHTO M 268 (2014) Standard Specification for

Retroreflective Sheeting for Flat and

Vertical Traffic Control Applications

AASHTO MASH (2016) Manual for Assessing Safety

Hardware - Second Edition

AMERICAN WOOD PROTECTION ASSOCIATION (AWPA)

AWPA T1 (2020) Use Category System: Processing and

Treatment Standard

AWPA U1 (2020) Use Category System: User

Specification for Treated Wood

ASTM INTERNATIONAL (ASTM)

ASTM A36/A36M (2019) Standard Specification for Carbon

Structural Steel

ASTM A123/A123M (2017) Standard Specification for Zinc

(Hot-Dip Galvanized) Coatings on Iron and

Steel Products

ASTM A320/A320M (2017b) Standard Specification for

Alloy-Steel and Stainless Steel Bolting for Low-Temperature Service

ASTM A499 (2015, R 2020) Standard Specification for

Steel Bars and Shapes, Carbon Rolled from

"T" Rails

ASTM A500/A500M (2020) Standard Specification for

Cold-Formed Welded and Seamless Carbon

Steel Structural Tubing in Rounds and

Shapes

SECTION 10 14 53 Page 3

ASTM A563 (2015) Standard Specification for Carbon and Alloy Steel Nuts

ASTM A563M (2007; R 2013) Standard Specification for

Carbon and Alloy Steel Nuts (Metric)

ASTM A653/A653M (2020) Standard Specification for Steel

Sheet, Zinc-Coated (Galvanized) or

Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A709/A709M (2018) Standard Specification for

Structural Steel for Bridges

ASTM A1011/A1011M (2018a) Standard Specification for Steel

Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved

Formability, and Ultra-High Strength

ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate

ASTM B209M (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)

ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ASTM B221M (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)

ASTM C94/C94M (2020) Standard Specification for

Ready-Mixed Concrete

ASTM D4956 (2013) Standard Specification for

Retroreflective Sheeting for Traffic

Control

ASTM F436/F436M (2019) Standard Specification for Hardened

Steel Washers Inch and Metric Dimensions

ASTM F3125/F3125M (2019) Standard Specification for High

Strength Structural Bolts and Assemblies, Steel and Alloy Steel, Heat Treated, Inch

Dimensions 120 ksi and 150 ksi Minimum

Tensile Strength, and Metric Dimensions

830 MPa and 1040 MPa Minimum Tensile

Strength

U.S. FEDERAL HIGHWAY ADMINISTRATION (FHWA)

FHWA SHS (2004; Supplement 2012) Standard Highway

Signs

MUTCD (2009; Rev 2012) Manual on Uniform Traffic

SECTION 10 14 53 Page 4

Control Devices

NCHRP 350 (1993) Recommended Procedures for the

Safety Performance Evaluation of Highway

Features

1.2 GENERAL.

All signs must be in accordance with the MUTCD.

1.3 SUBMITTALS.

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the government officer that will review the submittal for the Government.

SD-03 Product Data Traffic Sign Posts, G, COR

FHWA Acceptance Letter

Traffic Sign Retroreflective Sheeting

SD-04 Samples

Flexible Posts

PART 2 PRODUCTS.

2.1 TRAFFIC SIGN POSTS.

2.1.1 Steel Flanged Channel Section (U-Shape)

Fabricate steel posts from steel conforming to ASTM A36/A36M or ASTM A499 and with a minimum yield strength of 30 ksi and a minimum tensile strength of 50 ksi. Punch or drill 5/16 to 3/8 inch diameter holes spaced at 25.4 1 or 2 inch centers along the centerline of the web prior to galvanizing for the entire length of the post. Galvanize posts after punching in accordance with ASTM A123/A123M.

2.1.2 Perforated Steel Tube

Fabricate steel posts from steel conforming to either ASTM A653/A653M, structural steel, Grade 50, Class 1, coating designation G90 or ASTM

A1011/A1011M, structural steel, Grade 50, hot-dip galvanized after punching in accordance with ASTM A123/A123M. Pre-punch holes approximately 7/16 inch in diameter spaced at approximately 1 inch centers along each side of the tube for the entire length of the post.

2.1.3 Steel Tube

Conform to ASTM A500/A500M, Grade B or C, and hot-dip galvanized in accordance with ASTM A123/A123M. Manufactured triangular slip bases must be approved by the Federal Highway Administration (FHWA) for use under the provisions of NCHRP 350, TL-2 or AASHTO MASH, TL-2. Submit a copy of the

FHWA Acceptance Letter.

2.1.4 Structural Steel H Section

Conform to ASTM A709/A709M, Grade 50 or 50W. Galvanize posts, fuse

SECTION 10 14 53 Page 5 plate and splice plate after fabrication in accordance with

ASTM A123/A123M.

2.1.4.1 Slip Base, Fuse Plate and Splice Plate

Conform to ASTM A36/A36M, minimum yield strength 345 MPa 50,000 psi.

2.1.4.2 High-Strength Bolts, Nuts and Washers

High strength bolts must conform to ASTM F3125/F3125M. Nuts must conform to

ASTM A563M ASTM A563. Washers must conform to ASTM F436/F436M. High strength bolts, nuts and washers must be zinc coated.

2.2 FLAT ALUMINUM SIGN PANELS.

Aluminum sign panels must conform to ASTM B209M ASTM B209, alloy-temper

6061-T6 or 5052-H38. The blanks must be free from laminations, blisters, open seams, pits, holes, other defects that may affect their appearance or use. The thickness must be uniform and the blank commercially flat.

2.3 EXTRUDED ALUMINUM SIGN PANELS.

Conform to ASTM B221MASTM B221, alloy 6063-T6. The maximum allowable deviation from flat on the face is 0.05 inches per foot. Aluminum edge molding must be in accordance with ASTM A320/A320M or SAE J405d austenitic steel, minimum yield strength of 30,000 psi.

2.4 TRAFFIC SIGN RETROREFLECTIVE SHEETING.

All background sheeting applied to flat sheet and extruded panel signs must be in accordance with ASTM D4956, Type III, IV, VII, VIII, IX or XI retroreflective sheeting and must have Class 1, 3, or 4 adhesive backing.

Retroreflective sheeting must be high intensity that is an unmetallized micro prismatic reflective material.

Retroreflective sheeting must have sufficient adhesion, strength and flexibility such that the sheeting can be handled, processed and applied according to the manufacturer's recommendations without appreciable stretching, tearing, cracking or other damage.

2.4.1 Legend and Border.

Apply retroreflective sheeting as legend and border in accordance with

ASTM D4956, Type IX, XI, or AASHTO M 268 Type C or D, Class 1.

Retroreflective sheeting must be an unmetallized cube corner microprismatic reflective material. Retroreflective sheeting applied as legend and border for specific signing applications, without a datum mark on the surface of the sheeting, must be evaluated for rotational sensitivity in accordance with AASHTO M 268, Section 3.3.1 and fabricated in accordance with AASHTO M 268, Section 3.3.2.

2.4.2 Screen Printed Transparent Colored Areas

For screen printed transparent colored areas or transparent colored overlay films on white sheeting, the coefficient of retroreflection (RA) must be no less than 70 percent of the original values for the corresponding color.

2.4.3 Adhesive Performance

SECTION 10 14 53 Page 6

Adhesive performance for retroreflective sheeting must be in accordance with ASTM D4956. The sheeting surface must be in condition to be readily screen processed and compatible with transparent overlay films, plus recommended transparent and opaque screen process colors. Furnish manufacturer's information as to the type of solvent or solvents that may be used to clean the surface of the sheeting without detrimental loss of performance and durability.

2.5 LETTERS, NUMERALS, ARROWS, SYMBOLS, AND BORDERS.

Apply letters, numerals, arrows, symbols, and borders on the retroreflective sheeting or opaque background of the sign using the direct or reverse screen process. Apply messages and borders of a color darker than the background to the paint or the retroreflective sheeting using the direct process. Messages and borders must be of a color lighter than the sign background and applied using the reverse screen process. Use opaque or transparent colors, inks, and paints of the type and quality recommended by the retroreflective sheeting manufacturer in the screen process. Perform the screening in a manner that results in a uniform color and tone, with sharply defined edges of legends and borders and without blemishes on the sign background that will affect intended use.

Air dry or bake the signs after screening according to the manufacturer's recommendations to provide a smooth hard finish. Reject any signs with blister's or other blemishes.

2.6 DELINEATOR POSTS.

2.6.1 Steel Posts

Fabricate posts from steel conforming to ASTM A36/A36M or ASTM A499 and having a minimum yield strength of 30 ksi and a minimum tensile strength of 50 ksi. Galvanize posts after punching in accordance with ASTM

A123/A123M.

2.6.2 Flexible Posts

Provide one-piece driveable or two-piece with driveable steel anchor flexible posts. Posts must be impact-resistant, integrally colored UV stabilized polymer or polycarbonate extrusion or fiberglass reinforced composite material. Other materials are subject to approval by the

Contracting Officer's Representative. Include a retroreflective sheeting plate with each post as indicated.

2.7 DELINEATOR RETROREFLECTORS.

2.7.1 Circular Prismatic Reflectors

Retroreflectors attached to steel posts must be a 3-inch minimum diameter acrylic plastic lens with prismatic optical elements and a smooth, clear, transparent face. Fabricate the back from similar material and fuse to the lens around the entire perimeter to form a homogeneous unit. Permanently seal the units against the intrusion of dust, water, or air. Mount the retroreflector unit in a housing fabricated from 1.6 mm

SECTION 10 14 53 Page 7

0.063-inch aluminum alloy or similar, or from cold-rolled, hot dip, galvanized steel, having a thickness of 0.064 inches. Provide the indicated color.

2.7.2 Retroreflective Sheeting

A retroreflective sheeting plate must be applied to each flexible post by the post manufacturer and must be in accordance with ASTM D4956, Type III, IV, V, VII, VIII, IX or XI retroreflective sheeting. Retroreflective sheeting must be high intensity that is an unmetallized cube corner micro prismatic reflective material. Provide the size and color of the retroreflective sheeting plate as indicated.

2.8 HARDWARE.

Bolts, nuts, post clips, lock and flat washers must be either aluminum alloy or commercial quality stainless steel, hot-dip galvanized or cadmium plated after fabrication. Bolts/nuts must be an approved tamper resistant design. Provide fiber washers of commercial quality.

2.9 CONCRETE.

ASTM C94/C94M, using 3/4 inch maximum aggregate, and having minimum compressive strength of 3000 psi at 28 days.

PART 3 EXECUTION.

3.1 SIGN POSTS.

3.1.1 Round Steel Tube

Sign posts consist of a base post and sign post. Embed steel sign base posts in concrete as indicated. Install manufactured triangular slip bases in accordance with the manufacturer's instructions.

3.2 SIGN PANELS.

Clean, degrease and etch the face of metal panels using methods recommended by the retroreflective sheeting manufacturer. After cleaning and degreasing, apply retroreflective sheeting material to the sign panels as recommended by the manufacturer. Perform shearing, cutting and punching prior to preparing the blanks for application of reflective material. Do not field drill holes in any part of the panel. Use nylon washers recommended by the sign sheeting manufacturer between the bolt heads and sign faces on flat sheet aluminum signs. Replace any damaged sign panels at no additional cost to the Government.

3.3 DELINEATORS.

Drive steel delineator posts into the ground in a manner that will not damage the post. Attach flexible delineator posts to steel anchors or drive into the soil in accordance with the manufacturer's instructions.

Demonstrate the method of installation for the Contracting Officer's

Representative to verify that posts will be installed without being damaged.

3.4 LOCATION AND POSITION OF SIGNS.

SECTION 10 14 53 Page 8

Locate and erect all signs in accordance with the drawings and MUTCD.

Vertically mount signs at right angles to the direction of, and facing, the traffic that they are intended to serve. Where mirror reflection from the sign face is encountered to such a degree as to reduce legibility, turn the sign slightly away from the road. Turn signs that are placed 30 feet or more from the pavement edge toward the road. On curved alignments, determine the angle of placement by the direction of approaching traffic rather than by the roadway edge at the point where the sign is located. Mounted signs must present a smooth flat surface varying no more than 3/8 inch from a 4-foot straightedge placed in any position on the face of the sign after erection. Mount signs on traffic signal posts with strap or clamp type sign supports. Each installed sign will be inspected by the Contracting Officer's representative prior to acceptance by the Government.

-- End of Section --