ATTACHMENT J Drawings~26.pdf
PDF 11 MB Posted
- Attached to
- ITB 25-0022 Stage Improvements
- Solicitation number
- S-P34048-00016221
- Issued by
- Washington County, Barlow City, Oregon
About this file
This is a Bid/Permit document package for theatrical stage upgrades at two Beaverton School District middle schools (Meadow Park MS and Mountain View MS) in Beaverton, Oregon. The project encompasses replacement of theatrical controls, audio-visual devices, and production lighting systems to make teaching and production spaces equivalent to other recently remodeled BSD high schools. The scope includes providing power to replacement lighting, controls, and AV devices, with all new lighting specified as LED fixtures. The project involves comprehensive electrical, theatrical lighting, audio-visual, and rigging system upgrades, with detailed drawings and specifications provided for all systems including production relay panels, equipment racks, control systems, and related infrastructure. The document package includes architectural floor plans, electrical single-line diagrams, luminaire schedules, AV panel schedules, assistive listening system specifications, and production rigging plans dated February 21, 2025 for bid purposes.
The project requires coordination among multiple consulting firms including Opsis Architecture (architect), Interface Engineering (theatrical electrical and theatrical systems), DCI Structural, DCW Cost Management, and The Shalleck Collaborative for production systems design. All new electrical work must comply with 2021 Oregon Energy Efficiency Specialty Code, 2021 Oregon Electrical Specialty Code, 2022 Oregon Structural Specialty Code, 2021 International Fire Code, and local City of Beaverton requirements. An allowance of $50,000 is included to cover potential costs for upgrading the electrical distribution system pending 30-day metering efforts per NEC 220.87. Existing electrical loads will be metered over 30 days with a 25-percent safety factor applied to confirm acceptable loads at panels. The project includes assistive listening system requirements with calculations based on seating capacity (10 receivers minimum, 3 hearing-aid compatible units for Meadow Park's 240-seat cafetorium).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BSD Meadow Park MS Stage Upgrades
BID / PERMIT
Beaverton School District 14100 SW Downing St, Beaverton OR 97006
02/21/2025
GENERAL
C COVER SHEET
GENERAL
A1.11 FLOOR PLAN LEVEL 01
ELECTRICAL
E0.01 SYMBOL LIST AND GENERAL NOTES – ELECTRICAL
E0.02 LUMINAIRE SCHEDULE – ELECTRICAL
E3.01 FLOOR PLAN LEVEL 01 – ELECTRICAL
E4.01 ENLARGED PLANS – ELECTRICAL
E4.02 ENLARGED PLANS – ELECTRICAL
E5.01 SINGLE LINE DIAGRAMS – ELECTRICAL
E6.01 SCHEDULES – ELECTRICAL
E7.01 DETAILS – ELECTRICAL
ED4.01 ENLARGED DEMO PLANS – ELECTRICAL
THEATRICAL PRODUCTION LIGHTING
PL0.01 PRODUCTION LIGHTING DEMOLITION PLAN
PL1.01 PRODUCTION LIGHTING DEVISE PLAN
PL3.01 PRODUCTION LIGHTING SINGLE-LINE AND SCHEDULE
PL4.01 PRODUCTION LIGHTING DETAILS
PL4.02 PRODUCTION LIGHTING MOUNTING DETAILS
THEATRICAL AUDIO-VISUAL
AV0.10 AV PANEL SCHEDULE, ALS, SCOPE INFO
AV0.20 AV WIRETYPE SCHEDILE & CABLE CONDUIT GUIDE
AV0.30 AV STANDARD DETAILS
AV0.50 AV DEMO PLAN
AV1.10 AV DEVICE PLAN & RCP LEVEL 01
AV2.10 AV PANEL EQPT PLAN, RCP, SECTIONS, ELEVATION
AV6.10 AV BLOCK DIAGRAMS
AV7.10 AV PANEL ELEVATIONS & CONDUIT DIAGRAM
AV8.10 AV MOUNTING DETAILS
AV8.20 AV MOUNTING DETAILS
THEATRICAL RIGGING
PR1.01 PRODUCTION RIGGING PLANS
AUDIENCE AND PROCINIUM STAGE
SHEET INDEX
VICINITY MAP Contact: Michael Lamberty Contact: Randall Heeb Contact: Eric Stoeser Contact: Jill Collins Contact: Chris Roybal Contact: Shirley Chalupa
503.356.4587 503.943.6226 206.489.2643 503.305.3240 503.382.2722 503.242.2448 Beaverton, OR, 97006 Portland, Oregon 97214 Portland, OR 97209 Portland, OR Portland, Oregon 97204 Portland, Oregon 97205 1260 NW Waterhouse Avenue 975 SE Main Street 220 NW 8th Ave. Disperse 100 SW Main St., 1600 921 SW Washington St., 560 Beaverton School District Opsis Architecture DCW Cost Management The Shalleck Collaborative, Inc. Interface Engineering, Inc. DCI Structural
OWNER ARCHITECT COST ESTIMATE THEATRICAL ELECTRICAL STRUCTURAL
THEATRICAL
REPLACE THEATRICAL CONTROLS, AUDIO-VISUAL DEVICES AND PRODUCTIONS LIGHTING. MAKE
TEACHING AND PRODUCTIONS SPACES EQUIVALENT TO OTHER BSD HIGH SCHOOLS THAT WERE
RECENTLY REMODELED.
ELECTRICAL
PROVIDE POWER TO REPLACEMENT LIGHTING, CONTROLS AND AV DEVICES. ALL NEW LIGHTING TO
BE LED FIXTURES.
OBSERVE METERING TO CONFIRM ACCEPTABLE LOADS AT PANELS.
THEATER UPGRADES
PROJECT SCOPE:
SECTION 303.1.3:
ASSEMBLY SPACES IN A GROUP E BUILDING ARE NOT INTENDED TO BE
REGULATED AS SEPARATE GROUP A OCCUPANCIES, REGARDLESS OF
THEIR FLOOR AREA, BUT RATHER AN EXTENSION OF THE GROUP E
CLASSIFICATION.
GROUP E EDUCATIONAL OCCUPANCY FOR STUDENTS
OCCUPANCY CLASSIFICATION (Section 303 & 304)
CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
ACCOUNT R27116
TAX LOT: 1S104BC00100
OSSC CHAPTER 11: NOT APPLICABLE TO PROPOSED SCOPE
NFPA 101 (NOTE: LOCAL CODE WILL TAKE PRECEDENCE. DEVIATIONS
FROM NFPA IN INDIVIDUAL SECTIONS.)
2021 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2021 OREGON PLUMBING SPECIALTY CODE
2021 OREGON ELECTRICAL SPECIALTY CODE
2022 MECHANICAL SPECIALTY CODE
2021 INTERNATIONAL FIRE CODE
APPLICABLE CODE: 2022 OREGON STRUCTURAL SPECIALTY CODE
JURISDICTION: CITY OF BEAVERTON
BEAVERTON, OR 97006
14100 SW DOWNING STREET
PROJECT ADDRESS: MEADOW PARK MIDDLE SCHOOL
CHAPTER 1: ADMINISTRATION
CODE ANALYSIS
GRAPHIC SCALE
(IN FEET)
STOR12
B O Y S
LO
C K E R
G
IR
LS
LO
C K E R
STOR16
STOR18
BOYS1GIRLS1
CORRIDOR2
A
H A
LL
C E N T R A L
MAIN ENTRANCE
CAFETERIA
STAFF
KITCHEN
A
H A
LL
S O U T H
A-17
BOILER
MAIN GYM
WEST GYM
C-13B
OFF5OFF4
STOR8 STOR9
OFF3
STOR10
STOR15
S T O R
CUST OFF
CORRIDOR1
PRIN
HEALTH
RR1
FILE
WORK
ROOM
A-10
VP1
VP2
OFF1
MAIN
OFFICE
RR3
RR4
CONF
OFF2
STOR1 STOR9 M
E C H
UPPER
GYM
STOR2 STOR3
STOR7
STOR8
A-19
A-2
A-4
A-6
S
TO
R
S
TO
R
A-8
A
H A
LL
N O R
TH
A-1
A-3
A-5
A-7
A-9
B-1
B-3
B-5
B-7
B-9
B-2
B-4
B-6
B-8
S
TO
R
4 STOR3
C-1
C-3
C-5
C-7A
C
R E S O U R C E
C
H A
LL
N O R
TH
C-2
C-4
C-6
C-8
S
TO
R
S
TO
R
B
H A
LL
N O R
TH
A-15
A-13
A-11
COUNS1COUNS2
B-14
B-12
B-10
B
H A
LL
C E N
TR
A L
LIBRARY
LIB
OFF
STU
STORE
AV
PRODTVSTAFF
LIB
CUST2
MEN1
C-10
C-12
C
H A
LL
C E N
TR
A L
C-9
C-11
MECH3
GIRLS2BOYS2
WOMEN1
GIRLS3BOYS3
MECH2
BOYS4GILRS4
C-13
C-13A
STOR14
STOR11
CUST3
MECH1
ISS
RR5
QUIET
ROOMS
STOR4 STOR5 STOR6
STOR13
CUST1
STOR7
R O O M
SCI
STOR
PROD
STOR
ELEC
RR
QUIET
RM
STOR
STOR19
FLOOR PLANS SHEET NOTES
1.
2.
3.
4.
5.
6.
7.
REFERENCE SHEET AX.XX FOR MOUNTING HEIGHTS AND GENERAL
INFORMATION
REFERENCE LIGHTING / ELECTRICAL FOR LIGHTING TYPES. NOT ALL
LIGHTING IS SHOWN ON THE ARCHITECTURAL PLAN
REFERENCE EXTERIOR ELEVATIONS FOR EXTERIOR MATERIALS
ALL OUTSIDE INTERIOR CORNERS WITHOUT FRL WALL COVERING TO HAVE
4' HIGH S.S. CORNER GUARDS
ALL FURNITURE SHOWN FOR REFERENCE ONLY - OFOI.
PROVIDE BLOCKING AS REQUIRED FOR ALL LOCATIONS TO RECEIVE FRP
PANEL FINISH
PROVIDE BLOCKING AT LOCATIONS TO RECEIVE NEW TOILET
ACCESSORIES
A
B
SCOPE OF WORK
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date plo tte d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s ize
" x
Revision
2/
/2
5:
:4
PM
FLOOR PLAN
LEVEL 01
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
A1.11 4921-01
02/21/2025
BID / PERMIT
Beaverton School District copyright 2025
N
1/16" = 1'-0"A1.11 1 Level 01
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :1
A
M
SYMBOL LIST
AND GENERAL
NOTES -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E0.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
E0.01 SYMBOL LIST AND GENERAL NOTES - ELECTRICAL
E0.02 LUMINAIRE SCHEDULE - ELECTRICAL
ED4.01 ENLARGED DEMO PLANS - ELECTRICAL
E3.01 FLOOR PLAN LEVEL 01 - ELECTRICAL
E4.01 ENLARGED PLANS - ELECTRICAL
E4.02 ENLARGED PLANS - ELECTRICAL
E5.01 SINGLE LINE DIAGRAMS - ELECTRICAL
E6.01 SCHEDULES - ELECTRICAL
E7.01 DETAILS - ELECTRICAL
SHEET INDEX
Abbreviations
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ARF ABOVE RAISED FLOOR
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AWG AMERICAN WIRE GAUGE
A AMPERES, AMBER
AV AUDIO VISUAL
AHJ AUTHORITY HAVING JURISDICTION
AIC AVAILABLE INTERRUPTING CAPACITY
BAS BUILDING AUTOMATION SYSTEM
CA CABLE
CAT CATEGORY
CLG CEILING
CB CIRCUIT BREAKER
C CONDUIT, CLOSE, CONTROL
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
COORD COORDINATE
CU COPPER
dB DECIBEL
(X) DEMOLISH
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DIV DIVISION
DN DOWN
DWG DRAWING
EA EACH
EMT ELECTRICAL METALLIC TUBING
ENT ELECTRICAL NON-METALLIC TUBING
ESD ELECTROSTATIC DISCHARGE
EL ELEVATION
E EMERGENCY
EF EXHAUST FAN
(E) EXISTING
FMS FACILITY MANAGEMENT SYSTEMS
FF FINISH FLOOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FMC FLEXIBLE METAL CONDUIT
FT FOOT, FEET
FBO FURNISHED BY OTHERS
G, GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFI GROUND FAULT INTERRUPTER
GFP GROUND FAULT PROTECTION
GE GROUNDING EQUALIZER
HH HANDHOLE
HT HEIGHT
HC HORIZONTAL CROSS CONNECT
ID IDENTIFICATION
IN INCH, INCHES
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
IMC INTERMEDIATE METAL CONDUIT
IG ISOLATED GROUND
KV KILOVOLT
KVA KILOVOLT AMPERES
KW KILOWATT
LED LIGHT EMITTING DIODE
LNC LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT
LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
LV LOW VOLTAGE
MOCP MAXIMUM OVERCURRENT PROTECTION
MHz MEGAHERTZ mA MILLIAMPERES
MIN MINIMUM
MCA MINIMUM CIRCUIT AMPS
MISC MISCELLANEOUS
M MOTOR
MCC MOTOR CONTROL CENTER
MT, MTD MOUNT, MOUNTED
MDU MULTI-DWELLING UNIT
NEC NATIONAL ELECTRIC CODE
NESC NATIONAL ELECTRIC SAFETY CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
N NEUTRAL
(N) NEW
NC NORMALLY CLOSED
NO NORMALLY OPEN
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OSP OUTSIDE PLANT
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
PNL PANEL
PH PHASE
PVC POLY-VINYL-CHLORIDE
PWR POWER
QTY QUANTITY
REF REFERENCE
(R) RELOCATE
RFI REQUEST FOR INFORMATION
REQD REQUIRED
RMC RIGID METAL CONDUIT
RM ROOM
SHT SHEET
SIM SIMILAR
SPKR SPEAKER
STD STANDARD
SPD SURGE PROTECTION DEVICE
SWBD SWITCHBOARD
TBB TELECOMMUNICATIONS BONDING BACKBONE
TGB TELECOMMUNICATIONS GROUNDING BUS BAR
TTB TELEPHONE TERMINAL BOARD
TBD TO BE DETERMINED
XFMR TRANSFORMER
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TP TRANSITION POINT
TYP TYPICAL
UG UNDERGROUND
UL UNDERWRITERS LABORATORIES
UPS UNINTERRUPTIBLE POWER SUPPLY
UON UNLESS OTHERWISE NOTED
VFD VARIABLE FREQUENCY DRIVE
VRFY VERIFY
V VOLTS, VOLTAGE
WP WEATHERPROOF
WG WIRE GUARD
W WIRE, WHITE
W/ WITH
W/O WITHOUT
WAO WORK AREA OUTLET
Connections / Equipment
COMBINATION ADJUSTABLE FREQUENCY DRIVE WITH SAFETY
DISCONNECT SWITCH. FURNISHED BY DIVISION 23 AND INSTALLED
BY DIVISION 26.
COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH
CONTACTOR COIL
HEAVY DUTY FUSED DISCONNECT SWITCH
MOTOR CONNECTION
NON-FUSED DISCONNECT SWITCH
RELAY
REMOTE DRIVER FOR LED LUMINAIRES
TRANSFORMER
FIRE SMOKE DAMPER
SMOKE DAMPER
CEILING MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
WALL-MOUNTED JUNCTION BOX
MAGNETIC DOOR HOLDER
Fire Alarm
FIRE ALARM CONTROL PANEL
NOTIFICATION APPLIANCE CIRCUIT PANEL
FIRE ALARM ANNUNCIATOR PANEL
General
DETAIL NUMBER AND SHEET LOCATION
EQUIPMENT IDENTIFICATION
FOOD SERVICE EQUIPMENT / CALCULATION TAG
KEYED NOTE
POINT OF CONNECTION
SECTION NUMBER AND SHEET LOCATION
DEMOLISH
EXISTING WORK
NEW WORK
Lighting
LUMINAIRE RECESSED IN WALL
LUMINAIRE RECESSED IN WALL CONNECTED TO EMERGENCY/LIFE
SAFETY CIRCUIT
SURFACE MOUNTED LUMINAIRE CONNECTED TO EMERGENCY/LIFE
SAFETY CIRCUIT
SURFACE OR PENDANT MOUNTED STRIPLIGHT
WALL MOUNTED 6" WIDE LUMINAIRE
WALL MOUNTED 6" WIDE LUMINAIRE CONNECTED TO
EMERGENCY/LIFE SAFETY CIRCUIT
WALL MOUNTED LUMINAIRE
WALL MOUNTED LUMINAIRE CONNECTED TO EMERGENCY/LIFE
SAFETY CIRCUIT
Miscellaneous
BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO
PANEL WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM
UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE
CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL
CONDUCTORS. A SINGLE CURVED TICK MARK INDICATES
INSULATED GREEN GROUND CONDUCTOR. SECOND CURVED TICK
MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION WITH
YELLOW STRIPE) CONDUCTOR.
BRANCH PANEL
CIRCUIT BREAKER
DRY TYPE TRANSFORMER
FLUSH MOUNT EQUIPMENT ENCLOSURE AS NOTED
FLUSH WALL MOUNTED BRANCH PANEL
GROUND BAR
GROUNDING POINT
MAIN DISTRIBUTION PANEL / SUB DISTRIBUTION PANEL
POWER UTILITY POLE
SUBGRADE VAULT CATV
SUBGRADE VAULT POWER
SUBGRADE VAULT TELEPHONE
SURFACE MOUNT EQUIPMENT ENCLOSURE AS NOTED
TELEPHONE UTILITY POLE
UTILITY TRANSFORMER PAD/VAULT
Raceways
EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE
ELECTRICAL SYMBOL LIST
NOTE: This is a standard symbol list and not all items listed may be used.
EXISTING CONDUIT ROUTED BELOW FLOOR / GRADE
OVERHEAD PRIMARY SERVICE
OVERHEAD TELEPHONE SERVICE
UNDERGROUND CABLE TELEVISION SERVICE
UNDERGROUND PRIMARY SERVICE
UNDERGROUND SECONDARY SERVICE
UNDERGROUND TELEPHONE SERVICE
CONDUIT CONCEALED IN WALL OR CEILING SPACE
CONDUIT ROUTED BELOW FLOOR / GRADE
CONDUIT ELLED DOWN
CONDUIT ELLED UP
CONDUIT/WIRING CONTINUATION
CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED
PLASTIC BUSHING
FLEXIBLE CONDUIT
Switches and Receptacles
COMBINATION COMMUNICATIONS OUTLET AND DOUBLE DUPLEX
RECEPTACLE, FLUSH FLOOR
COMBINATION COMMUNICATIONS OUTLET AND DUPLEX
RECEPTACLE, FLUSH FLOOR
DUPLEX RECEPTACLE (MULTIPLE LETTERS INDICATE MULTIPLE
OPTIONS)
A = ABOVE COUNTER
B = CLOCK HANGER
C = FLUSH CEILING MOUNTED
E = EMERGENCY
F = ARC FAULT PROTECTED BY BREAKER IN PANEL
G = GROUND FAULT CIRCUIT INTERRUPTER
H = HOSPITAL GRADE
K = CHILD RESISTANT COVER
L = ISOLATED GROUND
P = PENDANT MOUNTED WITH CORD GRIPS. VERIFY PENDANT
LENGTH
R1 = HALF SWITCHED BY OCCUPANCY SENSOR RELAY
R2 = FULLY SWITCHED BY OCCUPANCY SENSOR RELAY
S = SPLIT WIRED
T = TAMPER RESISTANT SHUTTERED RECEPTACLE
U = USB PORT(S)
W = WEATHERPROOF CONTINUOUS USE COVER, GFCI PROTECTED,
WITH WEATHER-RESISTANT RECEPTACLE
DUPLEX RECEPTACLE, FLUSH FLOOR
DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR
DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX
RECEPTACLE FOR OPTIONS
SINGLE RECEPTACLE, FLUSH FLOOR
SINGLE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX
RECEPTACLE FOR OPTIONS
EQUIPMENT ELECTRICAL CONNECTION
SPECIAL PURPOSE RECEPTACLE. LETTER CODE DENOTES
RECEPTACLE CONFIGURATION
LX-XXR = NEMA CONFIGURATION TWIST-LOCK RECEPTACLE
X-XXR = NEMA CONFIGURATION STRAIGHT BLADE RECEPTACLE
P = PENDANT MOUNT WITH CORD GRIPS. VERIFY PENDANT LENGTH
X = COORDINATE RECEPTACLE CONFIGURATION WITH EQUIPMENT
BEING SUPPLIED
PENDANT RECEPTACLE WITH CORD GRIPS. VERIFY PENDANT
LENGTH. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR
OPTIONS
CEILING MOUNTED OCCUPANCY SENSOR
P = PASSIVE INFRARED
D = DUAL TECHNOLOGY
U = ULTRASONIC, 360 DEG RANGE
H = ULTRASONIC, HALLWAY PATTERN
v (LOWERCASE) = VACANCY CONTROL DESIGNATION
WALL MOUNTED OCCUPANCY SENSOR
P = PASSIVE INFRARED
D = DUAL TECHNOLOGY
v (LOWERCASE) = VACANCY CONTROL DESIGNATION
WALL MOUNTED OCCUPANCY SENSOR/SWITCH
S = PASSIVE INFRARED WITH INTEGRAL "OFF" SWITCH
T = DUAL RELAY PASSIVE INFRARED WITH TWO INTEGRAL "OFF"
SWITCHES
D = PASSIVE INFRARED WITH INTEGRAL DIMMER TO OFF.
v (LOWERCASE) = VACANCY CONTROL DESIGNATION
MULTIPLE CHANNEL SURFACE METAL RECEPTACLE RACEWAY
WITH LOW VOLTAGE DIVIDERS, LENGTH AND RECEPTACLES AS
INDICATED
SURFACE METAL RECEPTACLE RACEWAY
PHOTO ELECTRIC SWITCH
D = CONTINUOUS DIMMING PHOTOCELL
S = SWITCHED PHOTOCELL
SINGLE POLE SWITCH
2 = DOUBLE POLE SWITCH
3 = THREE-WAY SWITCH
4 = FOUR-WAY SWITCH
a THRU z (LOWERCASE) = LUMINAIRE CONTROL DESIGNATION
D = DIMMER
F = FAN SPEED CONTROL
K = KEY OPERATED SWITCH
L = LIGHTED HANDLE
M = MANUAL MOTOR STARTER WITH THERMAL OVERLOAD
P = SWITCH WITH PILOT LIGHT
S = SENTRY SWITCH
T = INTERVAL TIMER
W = WEATHERPROOF SWITCH
V = LOW VOLTAGE SWITCH
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
GENERAL ELECTRICAL
DEMOLITION NOTES
A. THE CONTRACTOR SHALL SEAL ALL UNUSED OPENINGS DUE TO ELECTRICAL DEMOLITION TO ENSURE
THAT FIRE-RESISTANCE IS MAINTAINED.
B. REFER TO SPECIFICATION SECTION 260000 FOR ADDITIONAL DEMOLITION AND EXISTING CONDITIONS
REQUIREMENTS.
C. ALLOW FOR TEMPORARY BASE BUILDING LIGHTS AS REQUIRED FOR PHASING AND/OR MEETING THE
CONSTRUCTION SCHEDULE.
D. DEVICES, CONDUIT, AND CONDUCTORS WITHIN WALLS SHOWN AS DEMOLISHED SHOULD BE REMOVED
BACK TO SOURCE UNLESS NOTED OTHERWISE.
GENERAL ELECTRICAL NOTES
A. IN FINISHED INTERIOR AREAS, ALL CONDUITS TO BE CONCEALED, UNLESS OTHERWISE NOTED.
SURFACE CONDUIT OR RACEWAY IS NOT PERMISSIBLE.
B. CONSULT ALL DRAWINGS AND SPECIFICATIONS IN THIS PROJECT AND BECOME FAMILIAR WITH ALL
EQUIPMENT TO BE INSTALLED. COORDINATE ALL ASPECTS OF THE CONSTRUCTION WITH OTHER
TRADES ON THE JOB TO ENSURE THAT ALL WORK AND MATERIALS REQUIRED TO PROVIDE A
COMPLETE AND OPERATIONAL FACILITY ARE INCLUDED IN BID.
C. EXISTING CONDITIONS ARE BASED ON AVAILABLE RECORD DRAWINGS AND FIELD OBSERVATIONS.
VERIFY LOCATIONS/CONDITIONS PRIOR TO CONSTRUCTION.
GENERAL LIGHTING NOTES
A. NO WIRE SMALLER THAN NO. 12 AWG SHALL BE USED FOR BRANCH CIRCUIT WIRING.
B. ALL LIGHTING SWITCHES, DIMMERS, AND MOTION SENSORS TO CONTROL LIGHTING IN THE ROOM THEY
ARE LOCATED IN UNLESS OTHERWISE NOTED.
C. ALL MOTION SENSORS TO BE MOUNTED AT LEAST 4' AWAY FROM ANY MECHANICAL DIFFUSERS.
D. IN FINISHED INTERIOR AREAS, ALL CONDUITS TO BE CONCEALED, UNLESS OTHERWISE NOTED.
SURFACE CONDUIT OR RACEWAY IS NOT PERMISSIBLE.
2/21/25
UL/IP DRIVER/
RATING POWER SUPPLY LIGHT SOURCE MFG/CATALOG # NOTES
A1 SURFACE MOUNTED LED
STRIPLIGHT; GENERAL
DISTRIBUTION; NOMINAL 3.5IN
WIDE x 3.5IN TALL x 48IN LONG
COLD ROLLED STEEL ROUND FROSTED
ACRYLIC
SURFACE MOUNTED WHITE UL DAMP INTEGRAL DRIVER;
0-10V DIMMING TO 1%
NOMINAL 10000 LUMENS; 3000K
LED; 80CRI
70.7 LITHONIA CLX SERIES;
OR APPROVED
A2 WALL MOUNTED LED
STRIPLIGHT; GENERAL
DISTRIBUTION; NOMINAL 3.5IN
WIDE x 3.5IN TALL x 48IN LONG
COLD ROLLED STEEL ROUND FROSTED
ACRYLIC
WALL MOUNTED WHITE UL DAMP INTEGRAL DRIVER;
0-10V DIMMING TO 1%
NOMINAL 10000 LUMENS; 3000K
LED; 80CRI
70.7 LITHONIA CLX SERIES;
OR APPROVED
B1 WALL MOUNTED LED SCONCE;
DIRECT AND INDIRECT
DISTRIBUTION; NOMINAL 5IN
WIDE x 5IN TALL x 4IN DEEP
FORMED ALUMINUM FROSTED ACRYLIC WALL MOUNTED AS SELECTED BY
ARCHITECT
UL DAMP INTEGRAL DRIVER;
0-10V DIMMING TO 1%
NOMINAL 1550 LUMENS; 3000K
LED; 80CRI
19 VISA NAYA SERIES;
OR APPROVED
C1 RECESSED IN-WALL LED
STEPLIGHT; NOMINAL 15IN
WIDE x 5.5IN TALL x 2.125IN
DEEP
DIE CAST ALUMINUM FROSTED ACRYLIC LENS WALL MOUNTED AS SELECTED BY
ARCHITECT
UL WET INTEGRAL DRIVER;
0-10V DIMMING TO 5%
NOMINAL 386 LUMENS; 3000K
LED; 80CRI
11 HYDREL HSL13 SERIES;
OR APPROVED
LUMINAIRE SCHEDULE
TYPE DESCRIPTION HOUSING SHIELDING MOUNTING FINISH
INPUT
WATTS
NOTES:
THIS LUMINAIRE SCHEDULE IS NOT COMPLETE WITHOUT A COPY OF THE PROJECT MANUAL CONTAINING THE ELECTRICAL SPECIFICATIONS.
DIMMING CONTROL PROTOCOL (0-10VDC, LINE VOLTAGE, DALI, ETC.) COMPATIBLE WITH LIGHTING CONTROL SYSTEM AS SPECIFIED AND SHOWN ON DRAWINGS.
PROVIDE +/- 12 INCH ADJUSTABILITY IN AIRCRAFT CABLE LENGTH WHERE USED.
COORDINATE ALL CEILING TYPES WITH LUMINAIRE LOCATIONS PRIOR TO ORDERING LUMINAIRES. COORDINATE INSTALLATION WITH REFLECTED CEILING PLAN.
SPECIFIED MANUFACTURERS ARE APPROVED TO SUBMIT BID. INCLUSION DOES NOT RELIEVE MANUFACTURER FROM SUPPLYING PRODUCT AS DESCRIBED.
PROVIDE SUBMITTALS THAT INCLUDE THE LUMINAIRE, LAMP AND DIMMABLE LED DRIVER INFORMATION OF EACH LUMINAIRE, WITH APPLICABLE OPTIONS CLEARLY CHECKED OR HIGHLIGHTED. SUBMITTALS NOT INCLUDING THIS INFORMATION WILL BE RETURNED AS REJECTED BY THE ENGINEER OF
RECORD.
PROVIDE FUNCTIONAL TESTING OF LIGHTING AND LIGHTING CONTROLS IN ACCORDANCE WITH THE 2021 OREGON ENERGY EFFICIENCY SPECIALY CODE (OEESC) FUNCTIONAL TESTING REQUIREMENTS
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :1
A
M
LUMINAIRE
SCHEDULE -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E0.02
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
J
J
J
B
B
(X) PANEL '2E'
(X) PANEL '2CS'
(X) PANEL '2CC'
(X) PANEL 'D'
(E)
(E) (E)
(E)
CAFETERIASTAFF
KITCHEN
STAGE
B
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
(X)
(X)
(X) (X)
(X)
(X) (X)
(X)
(X) (X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)
(X)(X)
(E) (E)
(E)
(E)
CAFETERIASTAFF
KITCHEN
STAGE
(X)
(X)
(X)
(X)
(X) (X)
(X)
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :1
A
M
ENLARGED
DEMO PLANS -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
ED4.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/8" = 1'-0"
1 ENLARGED LEVEL 01 STAGE DEMO PLAN - POWER
0' 4' 8' 16'
1/8" = 1'-0"
2 ENLARGED LEVEL 01 STAGE DEMO PLAN - LIGHTING
GENERAL SHEET NOTES
A. DEVICES NOTED WITH (X) ARE TO BE REMOVED ALONG WITH CONDUCTORS BACK
TO SOURCE, UNLESS NOTED OTHERWISE. EXISTING CONDUIT TO REMAIN.
SHEET KEYNOTES
1. REMOVE ALL EXISTING PRODUCTION LIGHTING RECEPTACLES AND HARDWIRED
LIGHT FIXTURES. REMOVE (E) CONDUCTORS BACK TO SOURCE AND KEEP EXISTING
CONDUIT AS MUCH AS PRACTICAL FOR RE-USE. REFER TO 'PL' & 'AV' SERIES
DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
STOR12
B O Y S
L O C K E R
G
IR
L S
L O C K E R
STOR16
STOR18
BOYS1GIRLS1
CORRIDOR2
A
H A L L
C E N T R A L
MAIN ENTRANCE
CAFETERIA
STAFF
KITCHEN
A
H A L L
S O U T H
A-17
BOILER
MAIN GYM
WEST GYM
C-13B
OFF5OFF4
STOR8 STOR9
OFF3
STOR10
STOR15
S T O R
CUST OFF
CORRIDOR1
PRIN
HEALTH
RR1
FILE
WORK
ROOM
A-10
VP1
VP2
OFF1
MAIN
OFFICE
RR3
RR4
CONF
OFF2
STOR1 STOR9
M E C H
A-2
A-4
A-6
S T O R
S T O R
A-8
A
H A L L
N O R T H
A-1
A-3
A-5
A-7
A-9
B-1
B-3
B-5
B-7
B-9
B-2
B-4
B-6
B-8
S T O R
4 STOR3
C-1
C-3
C-5
C-7A
C
R E S O U R C E
C
H A L L
N O R T H
C-2
C-4
C-6
C-8
S T O R
S T O R
B
H A L L
N O R T H
A-15
A-13
A-11
COUNS1COUNS2
B-14
B-12
B-10
B
H A L L
C E N T R A L
LIBRARY
LIB
OFF
STU
STORE
AV
PRODTVSTAFF
LIB
CUST2
MEN1
C-10
C-12
C
H A L L
C E N T R A L
C-9
C-11
MECH3
GIRLS2BOYS2
WOMEN1
GIRLS3BOYS3
MECH2
BOYS4GILRS4
C-13
C-13A
STOR14
STOR11
CUST3
MECH1
ISS
RR5
QUIET
ROOMS
STOR13
CUST1
STOR7
R O O M
SCI
STOR
PROD
STOR
ELEC
RR
QUIET
RM
STOR
STOR19
A
B
B
E4.01
E4.02
PANEL '4E' 1
E4.02
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :1
A
M
FLOOR PLAN
LEVEL 01 -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E3.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/16" = 1'-0"
1 LEVEL 01 OVERALL PLAN - ELECTRICAL
SHEET KEYNOTES
1. EXISTING PANEL TO BE REPLACED, SEE SINGLE-LINE
DIAGRAM FOR MORE INFORMATION.
J
J
J
J P
J P
J P
J C
J C
J C
J J
B
B
(E) PANEL '2E'
PANEL '2CS'
PANEL 'PRP' 2
(E)
(E) (E)
(E)
MOTORIZED SCREEN
C
C
C
+50"
CAFETERIASTAFF
KITCHEN
STAGE
2CS-21.
2CS-23.
2CS-22.
2CS-22.
2CS-24.
2CS-26.
2CS-25. 2CS-26. 2CS-26.
2CS-26. 2CS-26.
2CS-26.
2CS-26.
2CS-30.
2CS-28.
2CS-25.
B
'A1'
'A1'
'A1' 'A1'
'A1'
'A1' 'A1'
'A1'
'A1' 'A1'
'A1'
'A1'
'B1'
'B1'
'B1'
'B1'
'B1'
'B1'
'B1'
'B1'
'C1'
'C1'
'C1'
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
(E) (E) (E) (E)
'A2''A2'
(E)
(E)
(E)(E)
CAFETERIASTAFF
KITCHEN
STAGE
3D
3D
3D
3D 3D
DDD
4 4
4 4
4 4
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :2
A
M
ENLARGED
PLANS -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E4.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/8" = 1'-0"
1 ENLARGED LEVEL 01 STAGE PLAN - POWER
0' 4' 8' 16'
1/8" = 1'-0"
2 ENLARGED LEVEL 01 STAGE PLAN - LIGHTING
GENERAL SHEET NOTES
A. REFER TO 'PL' AND 'AV' SERIES DRAWINGS FOR CONDUIT AND CONDUCTOR SIZES
OF LV AND CONTROL WIRING.
B. FOR EACH 20A, 120V CIRCUIT, PROVIDE 2#10 CU, 1#10 CU GND., IN 3/4" CONDUIT
UNLESS NOTED OTHERWISE.
SHEET KEYNOTES
1. PROVIDE CONNECTION TO PRODUCTION LIGHTING FROM PRODUCTION RELAY
PANELS 'PRP'. REFER TO 'PL' SERIES DRAWINGS FOR CIRCUIT QUANTITY AND
CONTROLS INFORMATION.
2. PROVIDE 200A, 208V, 3PH CONNECTION FOR PRODUCTION LIGHTING RELAY PANEL
'PRP'. REFER TO 'PL' SERIES DRAWINGS FOR MORE INFORMATION.
3. PROVIDE (2) 20A, 120V, CIRCUITS FOR AV EQUIPMENT RACK 'RK-1' . REFER TO 'AV'
SERIES DRAWINGS FOR MORE INFORMATION.
4. CONNECT NEW LUMINAIRES TO CIRCUITS MADE AVAILABLE FROM DEMOLITION AND
TIE INTO EXISTING LIGHTING CONTROLS UNLESS NOTED OTHERWISE.
T
ATST
T
ATST
A
(X) TRANSFORMER 'TR-1'
(X) PANEL 'EM DIST'
(E) TRANSFORMER 'TR-3'
(E) SWITCHBOARD '4MDP'
(E) PANEL '2SDP'
(E) ATS
BOILER
CUST
STORAGE
A
TRANSFORMER 'TR-1'
PANEL 'EM DIST'
(E) PANEL '2SDP'
(E) SWITCHBOARD '4MDP'
(E) TRANSFORMER 'TR-3'
(E) ATS
BOILER
CUST
STORAGE
'TR-1' DISCONNECT
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :2
A
M
ENLARGED
PLANS -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E4.02
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 12'
3/16" = 1'-0"
1 DEMO ENLARGED LEVEL 01 BOILER ROOM - POWER
0' 4' 8' 12'
3/16" = 1'-0"
2 NEW ENLARGED LEVEL 01 BOILER ROOM - POWER
G
NEUT. BUS
(E) UTILITY
PRIMARY
FULL LENGTH
GROUND BUS
FIRST FLOOR
(E)MAIN DISTRIBUTION SWITCHBOARD (4MDP)
480Y/277 VOLT, 3 PHASE, 4 WIRE AVAILABLE
FAULT CURRENT: -----A
1000 AMP BUS
200A 3P
(E)GENERATOR
480V, 50 KW
(E) METER BASE
(E)CURRENT
TRANSF.
CABINET
M
(E)
(E) (E) (E) (E)
UTILITY
TRANSFORMER
T
(E)
200A 3P
200A 3P
200A 3P
60A 3P
60A 3P
(E)
400A 3P
(E) (E) (E) (E)
600A 3P
100A 3P
400A 3P
(E) ATS
(E) GEN DISCO
(X)PANEL
'EM DIST'
60A
MCB
(E)
(X)
(X)PANEL
'4E'
100A
MLO
(X)PANEL
'2E'
100A
MLO
(X)
(X)
(X)TRANSFORMER: TR-1
10kVA, 480-120/240V
3PH, 4W
(E)PANEL
'2SDP'
400A
MCB
(E)
(E)TRANSFORMER: TR-3
150kVA, 480-120/208V
3PH, 4W
(X)
(X)PANEL
'2CS'
100A
MLO
(X)PANEL
'2CC'
200A
MLO
(X)
(E) (E)
200A 3P
200A 3P
(E) (E)
(X)
(X)PANEL
'D'
200A
MLO
AREA OF WORK
G
NEUT. BUS
(E) UTILITY
PRIMARY
FULL LENGTH
GROUND BUS
FIRST FLOOR
(E)MAIN DISTRIBUTION SWITCHBOARD (4MDP)
480Y/277 VOLT, 3 PHASE, 4 WIRE AVAILABLE
FAULT CURRENT: -----A
1000 AMP BUS
200A 3P
(E)GENERATOR
480V, 50 KW
(E) METER BASE
(E)CURRENT
TRANSF.
CABINET
M
(E)
(E) (E) (E) (E)
UTILITY
TRANSFORMER
T
(E)
200A 3P
200A 3P
200A 3P
60A 3P
60A 3P
(E)
400A 3P
(E) (E) (E) (E)
600A 3P
100A 3P
400A 3P
(E) ATS
(E) GEN DISCO
(N)PANEL
'EM DIST'
60A
MCB
(E)
(N)PANEL
'4E'
100A
MLO
(N)PANEL
'2E'
100A
MLO
304X
(N)TRANSFORMER: TR-1
10kVA, 480-120/208V
3PH, 4W
(E)PANEL
'2SDP'
400A
MCB
(E)
(E)TRANSFORMER: TR-3
150kVA, 480-120/208V
3PH, 4W
(N)PANEL
'2CS'
100A
MLO
(E) (E)
200A 3P
200A 3P
(E) (E)
(N)PANEL
'PRP'
200A
MLO
AREA OF WORK
PRODUCTION
RELAY PANEL
1 1
4 3 3 3
5 7 8
#8 CU
F
30AS
30AF
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :2
A
M
SINGLE LINE
DIAGRAMS -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E5.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
A,C,S,X A=Aluminum C=Conduit only S=Service secondary X=Seperately derived system
FEEDER SCHEDULE
203 3 #12 CU, 1 #12 CU GND., IN 3/4" C
304 4 #10 CU, 1 #10 CU GND., IN 3/4" C.
304X 4 #10 CU, 1 #8 CU GND., IN 3/4" C.
404 4 #8 CU, 1 #10 CU GND., IN 3/4" C.
1004 4 #2 CU, 1 #8 CU GND., IN 1 1/4" C.
2004 4 #3/0 CU, 1 #6 CU GND., IN 2" C.
NO SCALE
1 DEMO ONE-LINE POWER DISTRIBUTION DIAGRAM
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
A. CALCULATED VALUES FOR AVAILABLE FAULT CURRENT ARE
SUITABLE FOR PLAN REVIEW PURPOSES BUT ARE NOT
CONSIDERED ACCURATE FOR ACTUAL INSTALLED FEEDER
ROUTING. UPDATE THE AS-BUILT DRAWING SET AT THE
CONSTRUCTION SITE WITH RESULTS OF CALCULATIONS FOR FAULT
CURRENT BASED ON ACTUAL FEEDER LENGTHS AND ROUTING
USING RESULTS OF LICENSED SOFTWARE PER APPROVED
ELECTRICAL DISTRIBUTION SYSTEM STUDY (SECTION 26 05 73).
B. PROVIDE ALLOWANCE OF $50,000 TO COVER ANY POTENTIAL
COSTS FOR UPGRADING THE ELECTRICAL DISTRIBUTION SYSTEM
PENDING THE 30-DAY METERING EFFORTS PER NEC 220.87.
NO SCALE
2 NEW ONE-LINE POWER DISTRIBUTION DIAGRAM
SHEET KEYNOTES
1. PROVIDE NEW CONDUCTORS IN EXISTING CONDUIT.
2. PROVIDE NEW 200A, 3P BREAKER TO FEED PANEL FROM '2SDP'.
3. DISCONNECT AND RECONNECT ALL EXISTING CIRCUITS, CONDUIT, AND
CONDUCTORS TO NEW ELECTRICAL DISTRIBTUION SYSTEM, UNLESS NOTED
OTHERWISE.
4. PANEL PROVIDED BY DIV. 11 AND INSTALLED BY DIV. 26.
5. MATCH EXISTING SCCR RATING.
6. DISCONNECT TO BE LOCATED WITHIN 25' OF SECONDARY SIDE OF THE
TRANSFORMER.
7. 42 KAIC.
8. 22 KAIC.
GENERAL SHEET NOTES
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :2
A
M
SCHEDULES -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E6.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
TOTAL AMPS (480V, 3 PHASE): 381.3 AMPS
TOTAL NEW DEMAND LOAD: 317 KVA
+ADDED (NEW) DEMAND: LOAD: 3.1 KVA
+25% SAFETY FACTOR: 313.9 KVA
POWER FACTOR (0.9): 251.1 KVA
(E) MAXIMUM DEMAND: 226.00 KW
AT EXISTING MAIN DISTRIBUTION SWITCHBOARD.MAXIMUM
12-MONTH PEAK DEMAND ON MAY, 2023 WAS 226 KW, AS PER
SERVING UTILITY
LOAD SUMMARY
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
Total NEC Demand Current: 0.0 A
Total Connected Current: 0.0 A
Total NEC Demand: 0.0 VA
Total Connected Load: 0.0 VA
Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals
E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer
R = Receptacles (to 10kVA100%, over 10 kVA... G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)
Motor (125% largest Motor + 100% remaining... K = Kitchen (Demand as per NEC Table 220.56) C = Continuous Load (125%) X = X-Rays (Demand per NEC...
Load Type Definitions:
1. EXISTING LOAD ON NEW BREAKER.
Notes:
Total Connected load Ph. C 0 A
Total Connected load Ph. B 0 A Total Demand Load: 0.0 kVA 0.0 A
Total Connected load Ph. A 0 A Panel Connected Load: 0.0 kVA 0.0 A
23 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 24
21 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 22
19 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 20
17 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 18
15 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 16
13 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 14
11 A-HALL CEILING LIGHTS, OFFICE -- 20 A 1 1 0 0 1 1 20 A -- EXISTING LOAD 12
9 2-HALL EXIT LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- LIBRARY PERIMETER LIGHTS 10
7 2-HALL, LIBRARY CEILING LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- LIBRARY EXIT LIGHTS 8
5 A,B,C HALL CEIL LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- I-HALL EXIT LIGHTS 6
3 A,B,C HALL EXIT LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- A-HALL CEILING, KITCHEN, I... 4
1 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 2
CKT Description/Location Type C.B. Pole Note
A B C A B C
Note Pole C.B. Type Description/Location CKT
Load (VA)
FOR AIC RATING SEE ONE-LINE DIAGRAM SUPPLIED FROM: EM DIST
EQUIPMENT RATING: 480/277 V, 3PH, 4 WIRE LOCATION:
BUS AMPACITY: 100 A ENCLOSURE: TYPE 1
MAIN LUG ONLY MOUNTING: RECESSED Accessories:
PANELBOARD: 4E
Total NEC Demand Current: 0.0 A
Total Connected Current: 0.0 A
Total NEC Demand: 0.0 VA
Total Connected Load: 0.0 VA
Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals
E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer
R = Receptacles (to 10kVA100%, over 10 kVA 50%) G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)
Motor (125% largest Motor + 100% remaining motors) K = Kitchen (Demand as per NEC Table... C = Continuous Load (125%) X = X-Rays (Demand per NEC 660.6)
Load Type Definitions:
1. EXISTING LOAD ON NEW BREAKER.
Notes:
Total Connected load Ph. C 0 A
Total Connected load Ph. B 0 A Total Demand... 0.0 kVA 0.0 A
Total Connected load Ph. A 0 A Panel... 0.0 kVA 0.0 A
23 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 24
21 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 22
19 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 20
17 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 18
15 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 16
13 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 14
11 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 12
9 GIRLS GYM CEIL & EXIT LTS -- 20 A 1 1 0 0 1 1 20 A -- FIRE ALARM 10
7 BOYS GYM CEIL LTS, EXIT LT GY... -- 20 A 1 1 0 0 1 1 20 A -- KITCHEN, MUSIC AREA EXIT LTS 8
5 GIRLS LOCKER RM CEIL LTS -- 20 A 1 1 0 0 1 1 20 A -- MAIN OFFICE RECEPTACLE 6
3 B'S GYM, B'S&G'S LOCKER EXIT... -- 20 A 1 1 0 0 1 1 20 A -- MAIN OFFICE COPIER 4
1 BOYS LOCKER RM CEIL LTS -- 20 A 1 1 0 0 1 1 20 A -- CAFETORIUM EM LIGHTS 2
CKT Description/Location Type C.B. Pole Note
A B A B
Note Pole C.B. Type Description/Location CKT
Load (VA)
FOR AIC RATING SEE ONE-LINE DIAGRAM SUPPLIED FROM: TR-1
EQUIPMENT RATING: 120/208 V, 3PH, 4 WIRE LOCATION:
BUS AMPACITY: 100 A ENCLOSURE: TYPE 1
MAIN LUG ONLY MOUNTING: RECESSED Accessories:
PANELBOARD: 2E
Total NEC Demand Current: 8.7 A
Total Connected Current: 8.5 A
Total NEC Demand: 3130.0 VA
R 2880.0 100.00% 2880.0 Total Connected Load: 3080.0 VA
Motor 200.0 125.00% 250.0
Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals
E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer
R = Receptacles (to 10kVA100%, over 10 kVA... G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)
Motor (125% largest Motor + 100% remaining... K = Kitchen (Demand as per NEC Table 220.56) C = Continuous Load (125%) X = X-Rays (Demand per NEC...
Load Type Definitions:
1. EXISTING LOAD ON NEW BREAKER.
2. NEW LOAD ON NEW BREAKER.
Notes:
Total Connected load Ph. C 5 A
Total Connected load Ph. B 8 A Total Demand Load: 3.1 kVA 8.7 A
Total Connected load Ph. A 14 A Panel Connected Load: 3.1 kVA 8.5 A
41 BUSSED SPACE -- -- 1 -- 0 1 20 A -- SPARE BREAKER 42
39 BUSSED SPACE -- -- 1 -- 0 1 20 A -- SPARE BREAKER 40
37 BUSSED SPACE -- -- 1 -- 0 1 20 A -- SPARE BREAKER 38
35 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 36
33 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 34
31 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 32
29 SPARE BREAKER -- 20 A 1 0 180 2 1 20 A R RK-1 EQUIPMENT RACK 30
27 SPARE BREAKER -- 20 A 1 0 180 2 1 20 A R RK-1 EQUIPMENT RACK 28
25 R CAFETORIUM, STAGE R 20 A 1 2 360 1,260 2 1 20 A R R STAGE 26
23 CAFETORIUM PROJECTOR R 20 A 1 2 180 200 2 1 20 A Motor STAGE PROJECTOR SCREEN 24
21 R CAFETORIUM R 20 A 1 2 360 360 2 1 20 A R R STAGE CEILING 22
19 CAFETORIUM RECEP. NORTH -- 20 A 1 1 0 0 -- -- -- -- -- 20
17 CAFETORIUM RECEP. NORTH -- 20 A 1 1 0 0 1 2 30 A -- EXISTING LOAD 18
15 STAGE LEFT RECEPTACLE -- 20 A 1 1 0 0 -- -- -- -- -- 16
13 CAFETORIUM WALL RE. S -- 20 A 1 1 0 0 1 2 30 A -- EXISTING LOAD 14
11 CAFETORIUM WALL RE. S -- 20 A 1 1 0 0 1 1 20 A -- EXISTING LOAD 12
9 STAGE CEILING LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- EXISTING LOAD 10
7 STAGE CEILING LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- STAGE PLATFORM LIGHTS 8
5 STAGE CEILING LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- PANEL & STAIR LIGHTS 6
3 STAGE CEILING LIGHTS -- 20 A 1 1 0 0 1 1 20 A -- STAGE REAR RECEPTACLE 4
1 CAFETORIUM BRACKET LTS -- 20 A 1 1 0 0 1 1 20 A -- STAGE REAR RECEPTACLE 2
CKT Description/Location Type C.B. Pole Note
A B C A B C
Note Pole C.B. Type Description/Location CKT
Load (VA)
FOR AIC RATING SEE ONE-LINE DIAGRAM SUPPLIED FROM:
EQUIPMENT RATING: 120/208 V, 3PH, 4 WIRE LOCATION:
BUS AMPACITY: 100 A ENCLOSURE: TYPE 1
MAIN LUG ONLY MOUNTING: SURFACE Accessories:
PANELBOARD: 2CS
Total NEC Demand Current: 0.0 A
Total Connected Current: 0.0 A
Total NEC Demand: 0.0 VA
Total Connected Load: 0.0 VA
Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals
E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer
R = Receptacles (to 10kVA100%, over 10 kVA... G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)
Motor (125% largest Motor + 100% remaining... K = Kitchen (Demand as per NEC Table 220.56) C = Continuous Load (125%) X = X-Rays (Demand per NEC...
Load Type Definitions:
Notes:
Total Connected load Ph. C 0 A
Total Connected load Ph. B 0 A Total Demand Load: 0.0 kVA 0.0 A
Total Connected load Ph. A 0 A Panel Connected Load: 0.0 kVA 0.0 A
19 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 20
17 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 18
15 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 16
13 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 14
11 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 12
9 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 10
7 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 8
5 -- -- -- -- -- 0 0 -- -- -- -- -- 6
3 -- -- -- -- -- 0 0 -- -- -- -- -- 4
1 TR-1 Spare 30 A 3 0 0 3 40 A Spare PANEL 4E 2
CKT Description/Location Type C.B. Pole Note
A B C A B C
Note Pole C.B. Type Description/Location CKT
Load (VA)
FOR AIC RATING SEE ONE-LINE DIAGRAM SUPPLIED FROM:
EQUIPMENT RATING: 480/277 V, 3PH, 4 WIRE LOCATION:
BUS AMPACITY: 100 A ENCLOSURE: TYPE 1
MAIN CIRCUIT BREAKER 60 A MOUNTING: SURFACE Accessories:
PANELBOARD: EM DIST
T E
L E
P H
O N
E /D
A T
A
D O
U B
L E
D U
P L E
X
W A
L L M
O U
N T
T E
L E
P H
O N
E
R E
C E
P T
A C
L E
D U
P L E
X R
E C
E P
T A
C L E
S W
IT
C
H E
S
O C
C U
P A
N C
Y S
E N
S O
R S
BRANCH
PANELBOARD
D U
P L E
X R
E C
E P
T A
C L E
BACKSPLASH COUNTERTOP
OUTLETS AT
CABINETS
PLUGMOLD
FINISHED FLOOR
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
Revision
EXPIRES: 06/30/26
/2
/2
:0 :2
A
M
DETAILS -
ELECTRICAL
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
E7.01
4921-01
2025-02-21
100% CONSTRUCTION
DOCUMENTS
BSD
PROJECT
CONTACT
www.interfaceengineering.com
Chris Roybal 2024-0306
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
NO SCALE
1 TYPICAL MOUNTING HEIGHTS
DISCONNECT AND REMOVE
DIMMER CONTROL PANEL
BOARD "D"
PL0.01
PL0.01
B
ABBREVIATIONS
# = POUNDS
AFF = ABOVE FINISHED FLOOR
CLR = CLEAR
DIV = SPECIFICATIONS DIVISION
EC = ELECTRICAL CONTRACTOR
EE = ELECTRICAL ENGINEER
FM = FLUSH MOUNT
HL = HOUSE LEFT
HR = HOUSE RIGHT
HT = HEIGHT
LF = LINEAR FEET
MAX = MAXIMUM
MIN = MINIMUM
NIC = NOT IN CONTRACT
NTS = NOT TO SCALE
OPP = OPPOSITE
PL = PRODUCTION LIGHTING
PR = PRODUCTION RIGGING
PS = PRODUCTION SEATING
RWL = RECOMMENDED WORKING LOAD
SAD = SEE ARCHITECTURAL DRAWINGS
SED = SEE ELECTRICAL DRAWINGS
SF = SQUARE FEET
SIM = SIMILAR
SL = STAGE LEFT
SM = SURFACE MOUNT
SMD = SEE MECHANICAL DRAWINGS
SR = STAGE RIGHT
SSD = SEE STRUCTURAL DRAWINGS
TYP = TYPICAL
UON = UNLESS OTHERWISE NOTED
VIF = VERIFY IN FIELD
LIGHTING GENERAL NOTES
1. THIS SHEET IS INTENDED TO PROVIDE PRODUCTION LIGHTING
SYSTEM INFORMATION ONLY. REFERENCE OTHER PRODUCTION
SYSTEMS, ARCHITECTURAL, AND ENGINEERING DOCUMENTS
FOR RELATED AREAS.
2. REFERENCE SPECIFICATIONS AND ELECTRICAL DRAWINGS FOR
DIVISION 26 INSTALLATION REQUIREMENTS.
3. ALL CIRCUITS SHALL HAVE A DEDICATED HOMERUN UNLESS
OTHERWISE INDICATED.
4. ALL CIRCUIT LOAD WIRING SHALL BE CONTINUOUS. NO SPLICES
WILL BE ACCEPTED BETWEEN RELAY PANEL LUGS AND DEVICE
TERMINAL STRIP.
5. ALL CIRCUITS SHALL HAVE A DEDICATED NEUTRAL. ALL
POWER DEVICE BOXES SHALL HAVE AT LEAST ONE DEDICATED
GROUND [PER (6) CIRCUITS] HOMERUN TO RELAY PANEL.
6. EXISTING CIRCUIT WIRING MAY BE RETAINED AND REUSED AS
DEEMED APPROPRIATE BY THE EEOR.
PROD. LIGHTING SCOPE MATRIX
POWER SYSTEMS (COMPLETE)
SCOPE
RESPONSIBILITY
EC PL
X
COMPANY SWITCHES X
CONDUIT & STANDARD BACK BOXES X
WIRE & PULL FOR PL SYSTEMS X
LOW-VOLT WIRE TERMINATION FOR PL SYSTEMS X
SUPPLY PL DEVICES & EQUIPMENT X
INSTALL PL EQUIPMENT X
ADDRESSING OF PERMANENT DMX FIXTURES X
PL PROGRAM & CONFIGURATION X
COORDINATE ALL CLEAR ZONES ON DRAWINGS/SPECS X
NTS4
EXISTING FLOOR BOXES
NTS3
EXISTING DISTRIBUTION PLAN
NTS5
EXISTING DIMMER CONTROL BOARD
Planning and Design of Theatres Production Systems | AV
The
Inc.
415-956-4100
1553 Martin Luther King Jr Way Berkeley CA 94709
Collaborative Shalleck www.shalleck.com
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
NOT FOR
CONSTRUCTION
Revision
/7
/2
:2 :0
P
M
PRODUCTION
LIGHTING DEMO
PLAN
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
PL0.01
4921-01
02/07/2025
100% CD
BSD
copyright 2021
1/8" = 1'-0"2
MEADOW PARK STAGE PLAN - DEMOLITION
1/8" = 1'-0"1
MEADOW PARK REFLECTED CEILING PLAN - DEMOLITION
REMOVE ALL EXISTING PRODUCTION
LIGHTING RECEPTACLE DEVICES, AND
HARDWIRED LIGHTING FIXTURES. POWER
RECEPTACLE WIRING TO REMAIN FOR REUSE
AS DEEMED APPROPRIATE PER THE EEOR
FLOORBOXES TO BE REMOVED KEEP CONDUIT STUB
IN FLOOR AND REPLACE WITH NEW FSR FLOORBOX
VERIFY SIZE OF OPENING IN FEILD
REMOVE THREE (3) OLD STYLE WELDED
BATTEN AND RACEWAY ASSEMBLIES;
STANDARD BATTENS FROM WHICH THOSE
HANG ARE TO REMAIN IN PLACE.
Jill Callout remove CS and lower pipe from assembly. retain upper pipe as rigging pipe
PRODUCTION LIGHTING SYMBOL KEY
NEMA 5-20R DUPLEX POWER RECEPTACLE
INTEGRAL TO DEVICE, 120V, 20A, CONSTANT
NEMA 5-20R QUAD POWER RECEPTACLE
INTEGRAL TO DEVICE, 120V, 20A, CONSTANT
2B
PLB-1
DEVICE LOCATION
T - TOUCH SCREEN CONTROL STATION
DEVICE TYPE
PRODUCTION LIGHTING DEVICE
DEVICE NUMBER
PRODUCTION RELAY CIRCUIT
PLD-1
GR
3 @ 20A-P
CIRCUITS AMPERAGE
NUMBER OF CIRCUITS
DEVICE LOCATION
DEVICE TYPE
IC - CONTROL BOX WITH (1) DMX IN
RECEPTACLE
IOC - CONTROL BOX WITH (1) DMX IN
AND (1) DMX OUT RECEPTACLE
OR - COMBO CONTROL AND POWER BOX
WITH (1) DMX RECEPTACLES AND
POWER RECEPTACLES PER SCHEDULE
OOR - COMBO CONTROL AND POWER
BOX WITH (2) DMX RECEPTACLES AND
POWER RECEPTACLES PER SCHEDULE
PRODUCTION LIGHTING DEVICE
DEVICE NUMBER
B
__________PLD- 4
OR
2@20A-P2@20A-P
__________PLD- 6
OR
2@20A-P2@20A-P
__________PLD- 5
OR
2@20A-P2@20A-P
__________PLD- 7
OR
2@20A-P2@20A-P
__________PLD- 2
IOC
_______PLB- 3
T
__________PLD- 1
IC
NEW ETC - SENSOR IQ 24 CIRCUIT
PANEL, IN LOCATION OF EXISTING
DIMMER CONTROL PANEL BOARD
"DP"
STAGE EQUIPMENT RACK "RK-1" WITH
120V CONVENIENCE OUTLET
(RACK BY AV)
(OUTLET BY ELECTRICAL)
B
__________PLD- 11
OOR
6@20A-P6@20A-P
__________PLD- 12
OOR
5@20A-P5@20A-P
__________PLD- 13
OOR
2@20A-P2@20A-P
__________PLD- 10
OR
1@20A-P1@20A-P
__________PLD- 9
OR
1@20A-P1@20A-P
__________PLD- 8
OR
1@20A-P1@20A-P
ABBREVIATIONS
# = POUNDS
AFF = ABOVE FINISHED FLOOR
CLR = CLEAR
DIV = SPECIFICATIONS DIVISION
EC = ELECTRICAL CONTRACTOR
EE = ELECTRICAL ENGINEER
FM = FLUSH MOUNT
HL = HOUSE LEFT
HR = HOUSE RIGHT
HT = HEIGHT
LF = LINEAR FEET
MAX = MAXIMUM
MIN = MINIMUM
NIC = NOT IN CONTRACT
NTS = NOT TO SCALE
OPP = OPPOSITE
PL = PRODUCTION LIGHTING
PR = PRODUCTION RIGGING
PS = PRODUCTION SEATING
RWL = RECOMMENDED WORKING LOAD
SAD = SEE ARCHITECTURAL DRAWINGS
SED = SEE ELECTRICAL DRAWINGS
SF = SQUARE FEET
SIM = SIMILAR
SL = STAGE LEFT
SM = SURFACE MOUNT
SMD = SEE MECHANICAL DRAWINGS
SR = STAGE RIGHT
SSD = SEE STRUCTURAL DRAWINGS
TYP = TYPICAL
UON = UNLESS OTHERWISE NOTED
VIF = VERIFY IN FIELD
LIGHTING GENERAL NOTES
1. THIS SHEET IS INTENDED TO PROVIDE PRODUCTION LIGHTING
SYSTEM INFORMATION ONLY. REFERENCE OTHER PRODUCTION
SYSTEMS, ARCHITECTURAL, AND ENGINEERING DOCUMENTS
FOR RELATED AREAS.
2. REFERENCE SPECIFICATIONS AND ELECTRICAL DRAWINGS FOR
DIVISION 26 INSTALLATION REQUIREMENTS.
3. ALL CIRCUITS SHALL HAVE A DEDICATED HOMERUN UNLESS
OTHERWISE INDICATED.
4. ALL CIRCUIT LOAD WIRING SHALL BE CONTINUOUS. NO SPLICES
WILL BE ACCEPTED BETWEEN RELAY PANEL LUGS AND DEVICE
TERMINAL STRIP.
5. ALL CIRCUITS SHALL HAVE A DEDICATED NEUTRAL. ALL
POWER DEVICE BOXES SHALL HAVE AT LEAST ONE DEDICATED
GROUND [PER (6) CIRCUITS] HOMERUN TO RELAY PANEL.
6. EXISTING CIRCUIT WIRING MAY BE RETAINED AND REUSED AS
DEEMED APPROPRIATE BY THE EEOR.
PROD. LIGHTING SCOPE MATRIX
POWER SYSTEMS (COMPLETE)
SCOPE
RESPONSIBILITY
EC PL
X
COMPANY SWITCHES X
CONDUIT & STANDARD BACK BOXES X
WIRE & PULL FOR PL SYSTEMS X
LOW-VOLT WIRE TERMINATION FOR PL SYSTEMS X
SUPPLY PL DEVICES & EQUIPMENT X
INSTALL PL EQUIPMENT X
ADDRESSING OF PERMANENT DMX FIXTURES X
PL PROGRAM & CONFIGURATION X
COORDINATE ALL CLEAR ZONES ON DRAWINGS/SPECS X
Planning and Design of Theatres Production Systems | AV
The
Inc.
415-956-4100
1553 Martin Luther King Jr Way Berkeley CA 94709
Collaborative Shalleck www.shalleck.com
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
NOT FOR
CONSTRUCTION
Revision
/7
/2
:2 :0
P
M
PRODUCTION
LIGHTING
DEVICE PLAN
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
PL1.01
4921-01
02/07/2025
100% CD
BSD
copyright 2021
1/8" = 1'-0"2 MEADOW PARK STAGE PLAN
1/8" = 1'-0"1 MEADOW PARK REFLECTED CEILING PLAN
D D
OVERSTAGE
STAGE
HOUSE
ND
PRP
PRODUCTION
RELAY PANEL
1-24 24@20A
PRODUCTION
LIGHTING
CIRCUITS
SEE SCHEDULE
BELOW
WIREWAY, S.E.D.D
20A, 120/208VAC, CONSTANT POWER (UNDER ELECT)
200A, 120/208V, 3Ø BREAKER OR DISCONNECT (UNDER ELECT)
INTERCONNECT WITH AV CONTROLLER
STAGE RIGHT WING
STAGE AND HOUSE
PRODUCTION LIGHTING
WIRING DEVICES
PLD - ##
OR
D D D
ALL LOW VOLTAGE WIRE PROVIDED AND INSTALLED BY DIVISION 26.
ALL LOW VOLTAGE WIRE TERMINATED BY DIVISION 11 PRODUCTION LIGHTING.
STANDARD BACKBOXES PROVIDED BY DIVISION 26,
UNLESS SURFACE MOUNTED OR A CUSTOM SPECIALTY BOX.
ALL CONDUIT FOR LOW VOLTAGE PLB/PLD
DEVICES SHALL BE 1" MIN DIAMETER
UNLESS OTHERWISE NOTED
HOUSE
D D D
D
D
2 4 6
1 2 3
N
D D 1 2
L
OVERSTAGE
STAGE
RK-1
SHARED RACK
PROVIDED BY AV -
SEE AV DRAWINGS
NETWORK SWITCH
PARADIGM TOUCHSCREEN
4 PORT DMX GATEWAY
4 PORT DMX GATEWAY
4 PORT DMX GATEWAY
4 PORT DMX GATEWAY
4 PORT DMX GATEWAY
ETC RESPONSE SNAPBACK
PARADIGM LIGHTING
PROCESSOR
UPS
__________PLD- 4
OR
__________PLD- 6
OR
__________PLD- 5
OR
__________PLD- 7
OR
__________PLD- 2
IOC
_______PLB- 3
T
__________PLD- 1
IC
__________PLD- 11
OOR
__________PLD- 12
OOR
__________PLD- 13
OOR
__________PLD- 10
OR
__________PLD- 9
OR
__________PLD- 8
OR
WIRING KEY
X
WIRE AND CONDUIT (BY DIV. 26) -
1" CONDUIT UON
WIRE & CONDUIT TYPE
N ETHERNET - CAT5e:
DRY: (1) BELDEN 1583A
A ARCH LTG CONTROL:
DRY: (1) BELDEN 8471 & (1) 14 AWG THHN
D DMX CONTROL:
DRY: (1) BELDEN 9729
WET: (1) WEST PENN AQ225 & (1) 14 AWG THWN
WET: (1) BELDEN 1594A
WET: (1) BELDEN 3107DB
L LINE VOLTAGE NORMAL CIRCUIT WIRING
(SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL DRAWINGS)
ABBREVIATIONS
# = POUNDS
AFF = ABOVE FINISHED FLOOR
CLR = CLEAR
DIV = SPECIFICATIONS DIVISION
EC = ELECTRICAL CONTRACTOR
EE = ELECTRICAL ENGINEER
FM = FLUSH MOUNT
HL = HOUSE LEFT
HR = HOUSE RIGHT
HT = HEIGHT
LF = LINEAR FEET
MAX = MAXIMUM
MIN = MINIMUM
NIC = NOT IN CONTRACT
NTS = NOT TO SCALE
OPP = OPPOSITE
PL = PRODUCTION LIGHTING
PR = PRODUCTION RIGGING
PS = PRODUCTION SEATING
RWL = RECOMMENDED WORKING LOAD
SAD = SEE ARCHITECTURAL DRAWINGS
SED = SEE ELECTRICAL DRAWINGS
SF = SQUARE FEET
SIM = SIMILAR
SL = STAGE LEFT
SM = SURFACE MOUNT
SMD = SEE MECHANICAL DRAWINGS
SR = STAGE RIGHT
SSD = SEE STRUCTURAL DRAWINGS
TYP = TYPICAL
UON = UNLESS OTHERWISE NOTED
VIF = VERIFY IN FIELD
LIGHTING GENERAL NOTES
1. THIS SHEET IS INTENDED TO PROVIDE PRODUCTION LIGHTING
SYSTEM INFORMATION ONLY. REFERENCE OTHER PRODUCTION
SYSTEMS, ARCHITECTURAL, AND ENGINEERING DOCUMENTS
FOR RELATED AREAS.
2. REFERENCE SPECIFICATIONS AND ELECTRICAL DRAWINGS FOR
DIVISION 26 INSTALLATION REQUIREMENTS.
3. ALL CIRCUITS SHALL HAVE A DEDICATED HOMERUN UNLESS
OTHERWISE INDICATED.
4. ALL CIRCUIT LOAD WIRING SHALL BE CONTINUOUS. NO SPLICES
WILL BE ACCEPTED BETWEEN RELAY PANEL LUGS AND DEVICE
TERMINAL STRIP.
5. ALL CIRCUITS SHALL HAVE A DEDICATED NEUTRAL. ALL
POWER DEVICE BOXES SHALL HAVE AT LEAST ONE DEDICATED
GROUND [PER (6) CIRCUITS] HOMERUN TO RELAY PANEL.
6. EXISTING CIRCUIT WIRING MAY BE RETAINED AND REUSED AS
DEEMED APPROPRIATE BY THE EEOR.
PROD. LIGHTING SCOPE MATRIX
POWER SYSTEMS (COMPLETE)
SCOPE
RESPONSIBILITY
EC PL
X
COMPANY SWITCHES X
CONDUIT & STANDARD BACK BOXES X
WIRE & PULL FOR PL SYSTEMS X
LOW-VOLT WIRE TERMINATION FOR PL SYSTEMS X
SUPPLY PL DEVICES & EQUIPMENT X
INSTALL PL EQUIPMENT X
ADDRESSING OF PERMANENT DMX FIXTURES X
PL PROGRAM & CONFIGURATION X
COORDINATE ALL CLEAR ZONES ON DRAWINGS/SPECS X
Planning and Design of Theatres Production Systems | AV
The
Inc.
415-956-4100
1553 Martin Luther King Jr Way Berkeley CA 94709
Collaborative Shalleck www.shalleck.com
Sheet Title
Project Name:
Project Adress:
Project Owner:
Opsis Architecture LLP 920 NW Avenue, Portland, OR 97209
503.525.9511 | info@opsisarch.com opsisarch.com
Sheet No.
Job No.
Key Plan
Status:
Date:
Revisions to Sheet
No. Date pl ot te d:
THESE DRAWINGS ARE THE PROPERTY OF OPSIS ARCHITECTURE
LLP AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER,
WITHOUT PRIOR WRITTEN PERMISSION.
sh ee t s iz e:
x
NOT FOR
CONSTRUCTION
Revision
/7
/2
:2 :0
P
M
PRODUCTION
LIGHTING
SINGLE LINE
AND SCHEDULE
BSD Meadow Park MS Stage Upgrades
14100 SW Downing St, Beaverton OR 97006
PL3.01
4921-01
02/07/2025
100% CD
BSD
copyright 2021
PRODUCTION LIGHTING DEVICE SCHEDULE - MEADOW PARK
D E
V
IC
E N
U M
B E
R
D E
V
IC
E T
Y P
E
HARDWIRE DMX LIGHTING DATA NETWORK
PRODUCTION RELAY
CIRCUITS
F
IN
IS
H
D E
V
IC
E D
E T
A
IL
MOUNTING REFERENCE
B A
C K
B O
X T
Y P
E
N O
T E
S
D M
X I
N
D M
X O
U T
P O
R T
C O
U N
T
P A
T C
H P
A N
E L
I D
P A
T C
H P
A N
E L
L O
C A
T
IO
N L
A B
E L
C
IR
C U
IT
Q
T Y
C
IR
C U
IT
B A
C K
B O
X M
O U
N T
IN
G
M O
U N
T
IN
G L
O C
A T
IO
N
1 IC 1 REAR OF HOUSE BLACK 3/PL401 SURFACE
MOUNT
@ OUTLET HT PER MFR
2 IOC 1 1 FRONT OF STAGE BLACK 4/PL401 FLUSH
MOUNT
@ OUTLET HT PER MFR COORDINATE FLUSH MOUNT
WITH DIV 26 AND FIELD
CONDITIONS
3 T 1 AV RACKMOUNT TOUCHSCREEN BLACK 5/PL401 RACKMOUNT IN
EQUIPMENT
RACK
N/A CUSTOM MOUNTED WITH
TOUCHSCREEN
4 OR 1 DOWNSTAGE LEFT FLOORBOX 2 1-2 BLACK 1/PL401 FLUSH
MOUNT
IN FLOORBOX FLOOR SIZE FLOORBOX TO FIT EXISTING
CUTOUT IN STAGE FLOOR
5 OR 1 DOWNSTAGE RIGHT FLOORBOX 2 3-4 BLACK 1/PL401 FLUSH
MOUNT
IN FLOORBOX FLOOR SIZE FLOORBOX TO FIT EXISTING
CUTOUT IN STAGE FLOOR
6…