Attachment J-3 Key Requirements Verification Matrix Rev A.xlsx
XLSX spreadsheet 11 KB Posted
- Attached to
- Navy Cable Ship Replacement T-ARC(X) Federal contract opportunity
- Solicitation number
- N00024-20-R-2211
About this file
This document contains an attachment with key requirements for a Navy cable ship replacement solicitation. The attachment lists over 20 technical requirements the Navy is seeking to procure including a minimum bollard pull of 120 metric tons, sustained speed of 15 knots, unrefueled range of 10,000 nautical miles at 15 knots, accommodations, bubble sweepdown flow, ice class, and seakeeping capabilities for cable operations, ROVs, sea plows and moonpools through sea states up to 5. Additional requirements include diesel engine emissions standards, dynamic positioning capabilities in redundant configurations through sea state 5, mission sonar systems, cable pathways, capacities for main and spare cable tanks, capabilities for cable deployment and recovery equipment, sea plow burial depth and speed, and ROV burial depth and speed. Interested parties should respond to solicitation N00024-20-R-2211 for the Navy Cable Ship Replacement T-ARC(X) program by submitting proposals no later than 2:00 PM EST on August 18, 2020, with no extensions permitted due to mission requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment J-3 Key Requirements Verification Matrix Rev B.xlsx | XLSX spreadsheet | |
| Attachment J-4 T-ARC(X) Specification Change Recommendation Form Rev A clean.docx | DOCX document | |
| Attachment J-1 T-ARC(X) System Spec Version 1.0 20200611 rev2.pdf | ||
| TARC RFP FINAL 17 Jul 2020.pdf | ||
| Attachment J-2 T-ARC(X) Data Requirements List 9 May 2020.docx | DOCX document | |
| Attachment J-1 T-ARC(X) System Spec Version 1.0 20200611 rev1.pdf | ||
| Attachment J-4 T-ARC(X) Specification Change Recommendation Form Rev A.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Attachment J-3 Key Requirements Verification Matrix | |||||
| Requirement Name | Requirement Description | Spec Section | Contractor Verification | Verification Method | Related DI |
| Bollard pull | At least 120 MT | 3.070.3 | |||
| Sustained Speed | 15 knots | 3.070.3 | |||
| Unrefueled Range | 10,000 nm at 15 knots | 3.070.3 | |||
| Accommodations | Total number of accommodations | 3.070.3 | |||
| Bubble Sweepdown | Flow streamlines requirement with respect to the MBSS-DW | 3.073.3 | |||
| Ice Class | ABS Baltic 1C | 3.070.12 | |||
| Seakeeping - Cable Ops | Cable operations through SS5 | 3.079 | |||
| Seakeeping - ROV | ROV LARS through SS5 | 3.079, 3.573.5.3 | |||
| Seakeeping - Sea Plow | Sea Plow LARS through SS5 | 3.079, 3.573.5.4 | |||
| Seakeeping - Moonpool | Moonpool UUV and Package LARS through SS3 and Package Heavy Lift through SS3 | 3.079, 3.573.5.5, 3.573.5.6 | |||
| Diesel engine emissions | Emission requirements per regulatory bodies | 3.233 | |||
| DP Capability - Environment | Position keeping and trackline through SS5 | 3.420 | |||
| DP Capability - Redundancy | ABS DPS-2 | 3.420 | |||
| Mission Sonar Systems | Mission sonar system transducer arrangements and sonar self-noise levels | 3.073.2 and 3.461 | |||
| Cable Pathways | Pathway to/from each cable tank to/from each of the three main CHE (two CDE and one LCE) | 3.595.1.1 | |||
| Cable Tank Capacity | Main cable tanks at least 3,200 m3 and 4,812 MT; Spare cable tanks at least 500 m3 and 688 MT | 3.595.2 | |||
| CDE Capability | CDE overboarding tension at least 50 MT; Hold two simultaneously up to 40 MT each | 3.595.5.1 | |||
| LCE Capability | 25,000 lb tension | 3.595.5.2 | |||
| Sea Plow Capability | 3m burial to 1,500 m depth up to 1.5 km/hr | 3.595.6 | |||
| ROV Capability | 1m burial to 3,000 m depth up to 400 m/hr | 3.595.7 | |||
| Moonpool Size | Sized to accommodate payloads | 3.595.9 |