About this file

This document appears to be Attachment F BLDG70-USU_Final-Design-Drawings, which is related to the Indefinite-Delivery, Indefinite-Quantity (IDIQ) Multiple Award Construction Contract (MACC) for Mechanical projects primarily in the NAVFAC Washington Area of Responsibility (AOR) or any other location by agreement of Contractor and Government, Solicitation Number N4008024R2396.

The attachment contains final design drawings for BLDG70-USU. The solicitation is for an IDIQ MACC contract for mechanical projects primarily in the NAVFAC Washington AOR. The contract will be awarded to multiple contractors. The work may be performed at any location by agreement between the contractor and the government. Relevant agencies include the Department of the Navy Naval Facilities Engineering Command.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

G-001

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

B U

IL

D

IN

G

P E

R F

O R

M D

E S

IG

N

F O

R H

V A

C

C O

V E

R S

H E

E T

SM

13142640

WC MR

1704503

BUILDING 70

VICINITY MAP LOCATION MAP

USU - 70 PERFORM

DESIGN FOR HVAC

BETHESDA, MARYLAND

NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND MID-ATLANTIC

UNIFORMED SERVICES UNIVERSITY OF THE HEALTH SERVICES

WASHINGTON, D.C.

04/21/2022

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

/2 mwrider Image

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

G-002

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

B U

IL

D

IN

G

IN

D E

X O

F D

R A

W

IN

G S

SM

13142641

WC MR

1704503

INDEX OF DRAWING

SHEET OF NAVFAC_NO SHEET NUMBER SHEET TITLE

ELECTRICAL

71 13142710 E-001 LEGEND, ABBREVIATIONS AND GENERAL NOTES

72 13142711 ED101A ELECTRICAL DEMOLITION - SECOND FLOOR - AREA A

73 13142712 ED101B ELECTRICAL DEMOLITION - SECOND FLOOR - AREA B

74 13142713 ED101D ELECTRICAL DEMOLITION - SECOND FLOOR - AREA D

75 13142714 ED102A ELECTRICAL DEMOLITION - THIRD FLOOR - AREA A

76 13142715 ED102B ELECTRICAL DEMOLITION - THIRD FLOOR - AREA B

77 13142716 ED102D ELECTRICAL DEMOLITION - THIRD FLOOR - AREA D

78 13142717 E-101A ELECTRICAL - SECOND FLOOR - AREA A

79 13142718 E-101B ELECTRICAL - SECOND FLOOR - AREA B

80 13142719 E-101D ELECTRICAL - SECOND FLOOR - AREA D

81 13142720 E-102A ELECTRICAL - THIRD FLOOR - AREA A

82 13142721 E-102B ELECTRICAL - THIRD FLOOR - AREA B

83 13142722 E-102D ELECTRICAL - THIRD FLOOR - AREA D

84 13142723 E-103C ELECTRICAL - ROOF FLOOR - AREA C

85 13142724 E-601 PANELBOARD SCHEDULES

INDEX OF DRAWING

SHEET OF NAVFAC_NO SHEET NUMBER SHEET TITLE

GENERAL

1 13142640 G-001 BUILDING 70 PERFORM DESIGN FOR HVAC - COVER SHEET

2 13142641 G-002 BUILDING 70 - INDEX OF DRAWINGS

ARCHITECTURAL

3 13142642 A-001 ARCHITECTURAL SYMBOLS, LEGENDS, ABBREVIATIONS AND NOTES

4 13142643 A-101A SECOND FLOOR RCP - AREA A

5 13142644 A-101B SECOND FLOOR RCP - AREA B

6 13142645 A-101D SECOND FLOOR RCP - AREA D

7 13142646 A-102A THIRD FLOOR RCP - AREA A

8 13142647 A-102B THIRD FLOOR RCP - AREA B

9 13142648 A-102D THIRD FLOOR RCP - AREA D

10 13142649 A-901 PHOTOGRAPHS

MECHANICAL

11 13142650 M-001 LEGEND, ABBREVIATIONS AND NOTES

12 13142651 MD101A SECOND FLOOR AREA A - DEMOLITION - DUCTWORK PLAN

13 13142652 MD101B SECOND FLOOR AREA B - DEMOLITION - DUCTWORK PLAN

14 13142653 MD101D SECOND FLOOR AREA D - DEMOLITION - DUCTWORK PLAN

15 13142654 MD102A THIRD FLOOR AREA A - DEMOLITION - DUCTWORK PLAN

16 13142655 MD102B THIRD FLOOR AREA B - DEMOLITION - DUCTWORK PLAN

17 13142656 MD102D THIRD FLOOR AREA D - DEMOLITION - DUCTWORK PLAN

18 13142657 MD103A MEZZANINE FLOOR AREA A - DEMOLITION - PIPING PLAN

19 13142658 MD103B MEZZANINE FLOOR AREA B - DEMOLITION - PIPING PLAN

20 13142659 MD103D MEZZANINE FLOOR AREA D - DEMOLTION - PIPING PLAN

21 13142660 MD104A SECOND FLOOR AREA A - DEMOLITION - PIPING PLAN

22 13142661 MD104B SECOND FLOOR AREA B - DEMOLITION - PIPING PLAN

23 13142662 MD104D SECOND FLOOR AREA D - DEMOLITION - PIPING PLAN

24 13142663 MD105A THIRD FLOOR AREA A - DEMOLITION - PIPING PLAN

25 13142664 MD105B THIRD FLOOR AREA B - DEMOLITION - PIPING PLAN

26 13142665 MD105D THIRD FLOOR AREA D - DEMOLITION - PIPING PLAN

27 13142666 MH101A MEZZANINE FLOOR AREA A - DUCTWORK PLAN

28 13142667 MH101B MEZZANINE FLOOR AREA B - DUCTWORK PLAN

29 13142668 MH101D MEZZANINE FLOOR AREA D - DUCTWORK PLAN

30 13142669 MH102A SECOND FLOOR AREA A - DUCTWORK PLAN

31 13142670 MH102B SECOND FLOOR AREA B - DUCTWORK PLAN

32 13142671 MH102C SECOND FLOOR AREA C - DUCTWORK PLAN

33 13142672 MH102D SECOND FLOOR AREA D - DUCTWORK PLAN

34 13142673 MH103A THIRD FLOOR AREA A - DUCTWORK PLAN

35 13142674 MH103B THIRD FLOOR AREA B - DUCTWORK PLAN

36 13142675 MH103C THIRD FLOOR AREA C - DUCTWORK PLAN

37 13142676 MH103D THIRD FLOOR AREA D - DUCTWORK PLAN

38 13142677 MI101A SECOND FLOOR AREA A - INSTRUMENTATION PLAN

39 13142678 MI101B SECOND FLOOR AREA B - INSTRUMENTATION PLAN

40 13142679 MI101C SECOND FLOOD AREA C - INSTRUMENTATION PLAN

41 13142680 MI101D SECOND FLOOR AREA D - INSTRUMENTATION PLAN

42 13142681 MI102A THIRD FLOOR AREA A - INSTRUMENTATION PLAN

43 13142682 MI102B THIRD FLOOR AREA B - INSTRUMENTATION PLAN

44 13142683 MI102C THIRD FLOOR AREA C - INSTRUMENTATION PLAN

45 13142684 MI102D THIRD FLOOR AREA D - INSTRUMENTATION PLAN

46 13142685 MP101A MEZZANINE FLOOR AREA A - PIPING PLAN

47 13142686 MP101B MEZZANINE FLOOR AREA B - PIPING PLAN

48 13142687 MP101D MEZZANINE FLOOR AREA D - PIPING PLAN

49 13142688 MP102A SECOND FLOOR AREA A - PIPING PLAN

50 13142689 MP102B SECOND FLOOR AREA B - PIPING PLAN

51 13142690 MP102C SECOND FLOOR AREA C - PIPING PLAN

52 13142691 MP102D SECOND FLOOR AREA D - PIPING PLAN

53 13142692 MP103A THIRD FLOOR AREA A - PIPING PLAN

54 13142693 MP103B THIRD FLOOR AREA B - PIPING PLAN

55 13142694 MP103C THIRD FLOOR AREA C - PIPING PLAN

56 13142695 MP103D THIRD FLOOR AREA D - PIPING PLAN

57 13142696 M-501 MECHANICAL DETAILS

58 13142697 M-601 MECHANICAL SCHEDULES

59 13142698 M-602 MECHANICAL SCHEDULES

60 13142699 M-603 MECHANICAL SCHEDULES

61 13142700 M-604 MECHANICAL SCHEDULES

62 13142701 M-605 MECHANICAL SCHEDULES

63 13142702 MI700 TEMPERATURE CONTROLS LEGEND & ABBREVIATIONS

64 13142703 MI701 MECHANICAL SEQUENCES AND SCHEMATICS

65 13142704 MI702 MECHANICAL SEQUENCES AND SCHEMATICS

66 13142705 M-801 AIRFLOW DIAGRAM AHU 2&3

67 13142706 M-802 AIRFLOW DIAGRAM AHU 5&6

68 13142707 M-803 AIRFLOW DIAGRAM AHU 9&10

69 13142708 M-804 AIRFLOW DIAGRAM AHU 12&13

70 13142709 M-805 HOT WATER FLOW DIAGRAM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

ARCHITECTURAL SYMBOLS

SPECIALTY ITEM NUMBER

SPECIALTY ITEM TAG

MATCHLINE

MATCHLINE SEE SHEET A-###

1. WORK MUST COMPLY WITH APPLICABLE CODES AND STANDARDS AS

REQUIRED BY THE AUTHORITY HAVING JURISDICTION.

2. DIMENSIONS GOVERN. DETAILS GOVERN OVER PLANS AND

ELEVATIONS. LARGE SCALE DETAILS OR PLANS GOVERN OVER

SMALL SCALE DETAILS OR PLANS. DO NOT SCALE DRAWINGS.

3. ANY MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR

SPECIFIED ARE DONE SO TO ESTABLISH A MINIMUM LEVEL OF

QUALITY.

4. CONSTRUCTION MUST MEET OR EXCEED LOCAL INDUSTRY

STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM

QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION.

INCORPORATE SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS

NOTED OTHERWISE.

5. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,

SECTIONS OR ELEVATIONS.

6. BRACE SUSPENDED CEILINGS, SUSPENDED ITEMS, ETC. ONLY TO

STRUCTURAL ELEMENTS ABOVE. DO NOT ANCHOR TO ROOF DECK,

PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT

OR SIMILAR ELEMENTS.

7. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED

FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS

SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE

CONTRACTOR.

8. BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE

WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE

ACTUAL CONDITIONS MUST BE REPORTED TO THE CONTRACTING

OFFICER FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.

9. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS

UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE

CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE

PROPER AND TIMELY EXECUTION OF THE INSTALLERS WORK. DO

NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE

CORRECTED. INSTALLATION CONSTITUTES ACCEPTANCE OF THE

SUBSTRATE AND/OR CONDITIONS.

10. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS MEANS THAT THE

CONDITIONS OR DIMENSION IS THE SAME OR REPRESENTATIVE FOR

SIMILAR CONDITIONS THROUGHOUT.

11. PRIOR TO BEGINNING ANY WORK, NOTIFY CONTRACTING OFFICER

OF ANY EXISTING MATERIALS OBSERVED TO POSSIBLY CONTAIN

ASBESTOS.

12. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO

ACCOMPLISH NEW WORK.

13. PROTECT EXISTING WORK TO REMAIN. PERFORM CUTTING TO

ACCOMPLISH REMOVALS NEATLY AND AS SPECIFIED FOR CUTTING

NEW WORK. REPAIR ADJACENT CONSTRUCTIO, WALLS AND FINISHES

DAMAGED DURING REMOVAL WORK. PATCH AS SPECIFIED FOR

PATCHING NEW WORK.

14. "EXISTING" INFORMATION ON THE CONTRACT DOCUMENTS HAS BEEN

OBTAINED FROM A PREVIOUS SET OF DRAWINGS, OR FROM FIELD

INVESTIGATION AND SUCH "EXISTING" INFORMATION MUST BE FIELD

VERIFIED.

15. COORDINATE WITH THE CONTRACTING OFFICER FOR DESIGNATED

CONSTRUCTION STAGING LOCATIONS, STORAGE AREAS, AND

CONSTRUCTION SEQUENCING.

16. THE PREMISES WILL BE OCCUPIED DURING THE CONSTRUCTION

SCHEDULE. COORDINATE WITH THE CONTRACTING OFFICER

REGARDING INTERRUPTIONS OF UTILITIES, TEMPORARY EXITS, DUST

PARTITIONS, DELIVERIES, AND OTHER JOB REQUIREMENTS.

17. CARE SHOULD BE MADE TO KEEP DUST AND NOISE FROM

DEMOLITION ACTIVITIES FROM THE OTHER PORTIONS AND FLOORS

OF THE BUILDING. ERECT AND MAINTAIN DUSTPROOF PARTITIONS.

COVER AND PROTECT FURNITURE, FURNISHINGS AND EQUIPMENT

THAT HAVE NOT BEEN REMOVED.

18. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION

REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO

ADJACENT BUILDING AREAS TO REMAIN.

ROOM NAME

A1 A-101

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

A101 INTERIOR ELEVATION

TAG

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SCALE

SHEET

REFERENCED FROM

EXTERIOR ELEVATION

TAG

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

A1 A-101

WALL / PARTIAL

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

A1 A-101

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

A1 A-101

BUILDING

KEYNOTE TAG

KEYNOTE NUMBER

A101 PHOTOGRAPH TAG

PHOTOGRAPH NUMBER

SHEET WHERE SHOWN

A1

SCALE

A-101 A1

OH

A1.

A1

A1.

A1.

A1

DETAIL TITLE

1/8" = 1'-0" (A-101) A1

DETAIL TITLE

1/8" = 1'-0" (A-101)

SHEET

REFERENCED FROM

PLAN

NORTH

MATERIALS LEGEND

2' x 2' ACOUSTICAL CEILING TILE

10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR

HVAC AIR SUPPLY GRILLE

HVAC EXHAUST OR RETURN GRILLE

HVAC LINEAR AIR SUPPLY GRILLE

EXPOSED CEILING

1' x 4' LED EMERGENCY FIXTURE -

SUSPENDED

EXIT SIGN

1' x 4' LED FIXTURE - SUSPENDED

2' x 4' LED EMERGENCY FIXTURE -

RECESSED

2' x 4' LED FIXTURE - RECESSED

2' x 2' LED FIXTURE - RECESSED

2' x 4' ACOUSTICAL CEILING TILE

GYPSUM CEILING

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

A-001

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

A R

C H

IT

E

C T

U R

A L

S Y

M B

O

LS

, L E

G E

N D

S , A

B B

R E

V

IA

T

IO

N S

A N

D N

O

TE

S

EV

13142642

WMC WMC

1704503

ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL GENERAL NOTES

PLYWD PLYWOOD

PROJ PROJECT

PVC POLYVINYL CHLORIDE

-R-

R RADIUS

RCP REFLECTIVE CEILING PLAN

RD ROOF DRAIN

RECP RECEPTACLE (ASK INT)

REFER REFERENCE

REINF REINFORCED

REQ'D REQUIRED

REV REVISION

RO ROUGH OPENING

-S-

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SID STRUCTURAL INTERIOR DESIGN (ASK

INT)

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE, AS IN "SQ FT"

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STOR STORAGE

STRUCT STRUCTURAL

SUPP SUPPORT

SUSP SUSPENDED

SYS SYSTEM

-T-

TD TRENCH DRAIN

TECH TECHNICAL

THRU THROUGH

TLT TOILET

TO TOP OF, AS IN "TO STEEL"

TYP TYPICAL

-U-

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

-V-

VENT VENTILATE, VENTILATOR

VERT VERTICAL

VOL VOLUME

-W-

W WIDTH

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WATER HEATER

WT WEIGHT

FP FIRE PROTECTION

FT FEET / FOOT

-G-

GA GAUGE

GALV GALVANIZED

GL GIRT LINE

GYP GYPSUM

GYP BD /

GWB

GYPSUM BOARD

-H-

H / HT HEIGHT

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HVAC HEATING, VENTILATION & AIR

CONDITIONING

-I-

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

-J-

JAN JANITOR'S CLOSET

-L-

L LEFT, LONG, LENGTH

LAB LABORATORY

LAV LAVATORY

LB or # POUND

LVR LOUVER

-M-

MACH MACHINE

MAINT MAINTENANCE

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR /

MNFR

MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

-N-

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

-O-

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OPNG OPENING

OPP OPPOSITE

-P-

PERIM PERIMETER

PKG PACKAGE

PL PLATE

PLMB PLUMBING

-A-

ADJ ADJACENT, ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

-B-

BD BOARD

BLDG BUILDING

BO BOTTOM OF, AS IN "BO STEEL"

-C-

CAB CABINET (ASK INT)

CID COMPREHENSIVE INTERIOR DESIGN

(ASK INT)

CJ CONTROL JOINT, CONSTRUCTION

JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUOUS

COORD COORDINATE

CORR CORRUGATED OR CORRIDOR

-D-

DBL DOUBLE

DEMO DEMOLITION

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DN DOWN

DR DOOR

DS DOWNSPOUT

DWG DRAWING

-E-

EA EACH

EEW EMERGENCY EYEWASH

EEWS EMERGENCY EYEWASH & SHOWER

EF EXHAUST FAN

EJ EXPANSION JOINT

EL ELEVATION, AS IN HEIGHT

ELEC /

ELECT

ELECTRIC / ELECTRICAL

ELEV ELEVATOR, OR ELEVATION AS IN

NORTH ELEV

EQ EQUAL

EQUIP EQUIPMENT

ETC AND SO FORTH (ETCETERA)

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

-F-

FD FLOOR DRAIN

FE FIRE EXTINGUISHER WITH WALL

BRACKET

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FURNITURE, FIXTURES & EQUIPMENT

FHC FIRE HOSE CABINET (WITH

EXTINGUISHER & BRACKET)

FHR FIRE HOSE REEL (WITH EXTINGUISHER

& BRACKET)

FIN FINISHED, FINISH

FLR FLOOR

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

1 74

CLASSROOM

A2057

OPEN OFFICE

A2051

CONFERENCE ROOM

A2052

CONFERENCE ROOM

A2053

STORAGE

A2054

LAB

A2050

2 3 5 6 8 9

STAIR

SA3

JAN

A2037

LAB

A2040

OPEN OFFICE

A2046

OPEN OFFICE

A2047

OPEN OFFICE

A2048

OPEN OFFICE

A2066

OPEN OFFICE

A2064

OFFICE

A2063

OFFICE

A2055

OFFICE

A2055A

OFFICE

A2056

OFFICE

A2058

OPEN OFFICE

A2060

OFFICE

A2062

CLASSROOM

A2061

CLASSROOM

A2065

CLASSROOM

A2049

CLASSROOM

A2045

CLASSROOM

A2041

H

I

J

K

L

MATCHLINE SEE SHEET A-101B MATCHLINE SEE SHEET A-101B

CORRIDOR

A2902

UTILITY CHASE

A2071

CORRIDOR

A2903

CORRIDOR

A2901

1 2

A-901 C1

A-901 C1

A-901 C1

A-901C1

A-901C1

A-901C1

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-101A

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

S E

C O

N D

F

LO

O R

R C

P

A R

E A

A

EV

13142643

WMC WMC

1704503

PLAN

NORTH

A

B

D

C

4' 8' 16'0'

PLAN

NORTH

1/8" = 1'-0" A1

SECOND FLOOR CEILING - AREA A

SHEET KEYNOTES

1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER

WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING

TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED

CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING

TILES AND GRIDS WITHIN AREA OF WORK.

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE

NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY

DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%

OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.

SIM

SIM

SIM

SIM

SIM

SIM

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

1 742 3 5 6 8 9

CLASSROOM

A2039

CLASSROOM

A2069

LAB PREP

A2035

STORAGE

A2070

OPEN OFFICE

A2067

OFFICE

A2068

CONFERENCE ROOM

A2074

OPEN OFFICE

A2034

ELEV

ELEV

LAB

A2033

ALCOVE

A2032

ELEV

STAIR

SA2

CLASSROOM

A2031

OFFICE

A2007A

OFFICE

A2002

OFFICE

A2004

OFFICE

A2006

E

F

G

MATCHLINE SEE SHEET A-101A MATCHLINE SEE SHEET A-101A

MATCHLINE SEE SHEET A-101D MATCHLINE SEE SHEET A-101D

M A

T C

H

LI

N E

S E

E S

H E

E T

A -1

C

M A

T C

H

LI

N E

S E

E S

H E

E T

A -1

C

CORRIDOR

A2904

UTILITY CHASE

A2071A

UTILITY CHASE

A2071

UTILITY CHASE

A2012

LAB

A2007

OFFICE

A2007B

OFFICE

A2007C

CORRIDOR

A2901

CORRIDOR

A2901

CORRIDOR

A2902

CORRIDOR

A2901

M A

T C

H

LI

N E

A R

E A

N O

T

IN

S C

O P

E M

A T

C H

LI

N

E A

R E

A N

O T

IN

S

C O

P E

A-901 C1

A-901 C1

A-901C1

A-901 C1

SIM

SIM

SIM

SIM

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-101B

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

S E

C O

N D

F

LO

O R

R C

P

A R

E A

B

EV

13142644

WMC WMC

1704503

PLAN

NORTH

A

B

D

C

1/8" = 1'-0" A1

SECOND FLOOR CEILING - AREA B

4' 8' 16'0'

PLAN

NORTH

SHEET KEYNOTES

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE

NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY

DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%

OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

1 7

C

A

42 3 5 6 8 9

CONFERENCE ROOM

A2008

OPEN OFFICE

A2010

CONFERENCE ROOM

A2011

CONFERENCE ROOM

A2015

CLASSROOM

A2009

CLASSROOM

A2013

CLASSROOM

A2017

CLASSROOM

A2021

CLASSROOM

A2025

CLASSROOM

A2029

OPEN OFFICE

A2030

OFFICE

OFFICE

A2027

OFFICE

A2024

OFFICE

A2020

OFFICE

A2020A

OFFICE

A2020B

OFFICE

A2019

B

D

MATCHLINE SEE SHEET A-101B MATCHLINE SEE SHEET A-101B

CORRIDOR

A2901

CORRIDOR

A2902

UTILITY CHASE

A2012

STORAGE

A2021E

CORRIDOR

A2905

A-901 C1

A-901 C1

A-901C1

A-901C1

A-901C1

SIM

SIM

SIM

SIM

SIM

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-101D

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

S E

C O

N D

F

LO

O R

R C

P

A R

E A

D

EV

13142645

WMC WMC

1704503

1/8" = 1'-0" A1

SECOND FLOOR CEILING - AREA D

PLAN

NORTH

A

B

D

C

4' 8' 16'0'

PLAN

NORTH

SHEET KEYNOTES

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE

NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY

DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%

OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

STAIR

A3S3

JAN

A3051

LAB

A3053

OFFICE

A3059

OPEN OFFICE

A3056

OFFICE

A3058

OFFICE

A3064

OFFICE

A3063

OFFICE

A3062

OFFICE

A3066

CORR

A3065

OPEN OFFICE

A3068

OFFICE

A3069

LAB

A3045

LAB

A3047

LAB

A3049

LAB

A3072

LAB

A3076

LAB

A3079

GLASS-WASHING ROOM

A3043

LAB

A3046

LAB

A3048

LAB

A3050

OFFICE

A3070

OFFICE

A3071

OFFICE

A3073

OFFICE

A3074

OFFICE

A3075

OFFICE

A3077

OPEN OFFICE

A3078

OFFICE

A3080

H

I

J

K

L

MATCHLINE SEE SHEET A-102B MATCHLINE SEE SHEET A-102B

OPEN OFFICE

A3060

UTILITY CHASE

A3086

CORRIDOR

A3901

LAB

A3047C

LAB

A3047B

LAB

A3047A

1 2 1 2 1 2

LAB

A3045A

OFFICE

A3057

OFFICE

A3061A

OFFICE

A3061B

CONFERENCE ROOM

A3067

ELEC

A3087

MECH

A3088

8' - 0" A.F.F.

OFFICE

A3042C OFFICE

A3042D

CORRIDOR

A3042

CORRIDOR

A3902

CORRIDOR

A3902

CORRIDOR

A3903

A-901 A2

A-901

A4

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-102A

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

TH

IR

D F

LO

O

R R

C P

A

R E

A A

EV

13142646

WMC WMC

1704503

PLAN

NORTH

A

B

D

C

4' 8' 16'0'

PLAN

NORTH

1/8" = 1'-0" A1

THIRD FLOOR CEILING - AREA A

SHEET KEYNOTES

1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER

WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING

TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED

CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING

TILES AND GRIDS WITHIN AREA OF WORK.

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

3 DEMOLISH GYPSUM CEILING COMPLETE.

4 INSTALL NEW ACT CEILING.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

MEDIA PREP

A3084

LAB

A3082

COLD STORAGE

A3093

COLD STORAGE

A3095

LAB

A3041

LAB PREP

A3038

CONFERENCE

A3035

OPEN OFFICE

A3036

CONFERENCE

A3037

LAB

A3039

LAB

A3040

OFFICE

A3042B

OFFICE

A3083

OFFICE

A3085

ELEV

ELEV

OFFICE

A3034

ALCOVE

A3032

ELEV

STAIR

A3S2

OFFICE

A3006

OPEN OFFICE

A3007

LAB

A3005

LAB

A3033

OFFICE

A3031

OFFICE

A3008

OFFICE

A3009C

OFFICE

A3009A E

F

G

MATCHLINE SEE SHEET A-102A MATCHLINE SEE SHEET A-102A

MATCHLINE SEE SHEET A-102D MATCHLINE SEE SHEET A-102D

M A

T C

H

LI

N E

S E

E S

H E

E T

A -1

C

M A

T C

H

LI

N E

S E

E S

H E

E T

A -1

C

CORRIDOR

A3901

CORRIDOR

A3901

CORRIDOR

A3904

LAB

A3094

UTILITY CHASE

A3086

LAB

A3033A

OFFICE

A3009B

STORAGE

A3030B

STORAGE

A3030C

OFFICE

A3081

OFFICE

A3042A

STORAGE

A3030D

CORRIDOR

A3902

M A

T C

H

LI

N E

A R

E A

N O

T

IN

S C

O P

E M

A T

C H

LI

N

E A

R E

A N

O T

IN

S

C O

P E

A-901C4

1 2

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-102B

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

TH

IR

D F

LO

O

R R

C P

A

R E

A B

EV

13142647

WMC WMC

1704503

PLAN

NORTH

A

B

D

C

4' 8' 16'0'

PLAN

NORTH

1/8" = 1'-0" A1

THIRD FLOOR CEILING - AREA B

SHEET KEYNOTES

1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER

WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING

TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED

CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING

TILES AND GRIDS WITHIN AREA OF WORK.

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

1 7

C

A

42 3 5 6 8 9

OPEN OFFICE

A3020

OFFICE

A3026

OPEN OFFICE

A3027

OPEN OFFICE

A3028

OPEN OFFICE

A3031A

OFFICE

A3031

OFFICE

A3008

OFFICE

A3010

OFFICE

A3011

OFFICE

A3012

OPEN OFFICE

A3016

OFFICE

A3017

LAB

A3030

LAB

A3025

OPEN OFFICE

A3009

OFFICE

A3009D

OFFICE

A3009E

OFFICE

A3009F

LAB

A3013A

LAB

A3013

LAB

A3018

LAB

A3023

OFFICE

A3009C

OFFICE

A3009A

CONFERENCE

A3014

B

D

MATCHLINE SEE SHEET A-102B MATCHLINE SEE SHEET A-102B

CORRIDOR

A3901

CORRIDOR

A3902

OFFICE

A3020B

OFFICE

A3020A

OFFICE

A3020C

OFFICE

A3022

OFFICE

A3020D

OFFICE

A3009B

STORAGE

A3030B

STORAGE

A3030C

LAB

A3030A

LAB

A3013BLAB

A3013C

CORRIDOR

A3905

STORAGE

A3030D

LAB

A3025A

ELEC

A3091A ELEC

A3091

TEL

A3090

LAB

A3013D

1 2 A-901

C2

1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET A-001.

2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND

EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.

3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.

MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF

WORK SHOWN ON THE REFLECTED CEILING PLAN.

4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY

ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231

QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING

SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS

NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.

REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.

REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK

BETWEEN DISCIPLINES.

5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.

REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES

ARE REPLACED.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

A-102D

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

TH

IR

D F

LO

O

R R

C P

A

R E

A D

EV

13142648

WMC WMC

1704503

PLAN

NORTH

A

B

D

C

4' 8' 16'0'

PLAN

NORTH

1/8" = 1'-0" A1

THIRD FLOOR CEILING - AREA D

SHEET KEYNOTES

1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER

WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING

TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED

CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING

TILES AND GRIDS WITHIN AREA OF WORK.

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

A-901

U S

U -7

P

E R

F O

R M

D E

S

IG

N F

O R

H V

A C

P H

O T

O G

R A

P H

S

EV

13142649

WMC WMC

1704503

NOT TO SCALE

C1

SECOND FLOOR TYPICAL CLASSROOM

NOT TO SCALE

C2 A3020

NOT TO SCALE

A4

A3053

NOT TO SCALE

C4

A3040

NOT TO SCALE

A2

A3047

SHEET KEYNOTES

1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER

WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING

TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED

CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING

TILES AND GRIDS WITHIN AREA OF WORK.

2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING

CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR

EXTENT OF WORK.

5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE

NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY

DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%

OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS IN THIS SET.

SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL

SHEET NOTES.

2. PATCH HOLES VACATED FROM REMOVAL OF PIPING, DUCTWORK.

3. REFER TO ARCHITECTURAL FOR WORK TO RESTORE CEILINGS DAMAGED BY

DEMOLITION OF MECHANICAL.

4. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR

REQUIRED TO PROVIDE COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS

INDICATED AND REQUIRED BY CODE.

5. PROVIDE ALL MECHANICAL EQUIPMENT AN APPURTENANCES IN ACCORDANCE

WITH MANUFACTURER'S RECOMMENDATIONS, AS INDICATED, AND AS

REQUIRED BY CODE. WHERE THE ABOVE REQUIREMENTS ARE IN CONFLICT,

PROVIDE THE MOST STRINGENT.

6. PROVIDE VIBRATION ISOLATORS FOR ALL MECHANICAL EQUIPMENT TO

PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE.

7. EXISTING DUCT AND PIPING SIZES INDICATED ARE APPROXIMATE. FIELD VERIFY

ALL DIMENSIONS.

8. LOCATE NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED CEILINGS

UNLESS OTHERWISE INDICATED.

9. 90 DEGREE MITERED DUCT ELBOWS IN THE SUPPLY AND RETURN DUCT SHALL

HAVE TURNING VANES.

10. AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED PIPE

LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE FOLLOWING PIPING, AT

10 FOOT ON CENTER ON THE PIPING MAINS AND 5 FOOT ON CENTER ON THE

BRANCH RUNOUTS FROM THE MAINS.

11. PIPE RUNOUTS MUST BE SIZED AS INDICATED ON EQUIPMENT SCHEDULES.

12. DUCT RUNOUT SIZE TO DIFFUSER, REGISTER, OR GRILLE MUST BE THE SAME

AS NECK SIZE.

13. MOUNT THERMOSTATS, HUMIDISTATS, AND EMERGENCY SHUTOFF SWITCHES

48 INCHES ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. REFER TO

ELECTRICAL DRAWINGS FOR LOCATION OF LIGHT SWITCHES AND COORDINATE.

14. SLOPE CONDENSATE PIPING 1/8 INCH PER FOOT DOWNWARD IN THE DIRECTION

OF FLOW. PROVIDE CLEANOUTS AT EACH CHANGE IN DIRECTION GREATER

THAN 45 DEGREES OR ONCE EVERY 45 FEET OF LINEAR PIPE LENGTH. UTILIZE

COMBINATION WYE AND 1/8 BENDS SHALL BE USED IN LIEU OF TEES.

15. MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND MAY NOT SHOW

EVERY OFFSET, FITTING, AND CONNECTION NECESSARY FOR A COMPLETE

INSTALLATION. PROVIDE ADDITIONAL OFFSETS, FITTINGS, AND CONNECTIONS

REQUIRED FOR COMPLETE AND OPERABLE SYSTEM.

16. VERIFY AND COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH

OTHER TRADES PRIOR TO BEGINNING WORK. WORK MUST PROVIDE ACCESS

FOR MAINTENANCE WITHOUT REQUIRING REMOVAL OR DISASSEMBLY OF

ADJACENT SYSTEMS.

GENERAL MECHANICAL NOTES

° DEGREES

Ø DIAMETER

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AP ACCESS PANEL

APD AIR PRESSURE DROP

AS AIR SEPARATOR

ATFP ANTITERRORISM FORCE PROTECTION

BD BALANCING DAMPER

BHP BRAKE HORSEPOWER

BOD BOTTOM OF DUCT

BR BASEBOARD RADIATOR

BTUH BRITISH THERMAL UNITS PER HOUR

C COMMON

Cv LOSS COEFFICIENT

CAV CONTSTANT AIR VOLUME

CFM CUBIC FEET PER MINUTE

CLG CEILING

CND CONDENSER

COP COEFFICIENT OF PERFORMANCE

CRAHU COMPUTER ROOM AIR HANDLING UNIT

CU CONDENSING UNIT

CHW CHILLED WATER

CW CONDENSER WATER

D CONDENSATE DRAIN

DB DRY BULB

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DP DIFFERNTIAL PRESSURE

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EF EXHAUST FAN

EFF EFFECTIVENESS

EQPT EQUIPMENT

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

EXF EXFILTRATION

F FAHRENHEIT

FCU FAN COIL UNIT

FD FIRE DAMPER

FT FEET

FT WG FEET WATER GAUGE

G NATURAL GAS

GPM GALLONS PER MINUTE

HGT HEIGHT

HP HEAT PUMP, HORSEPOWER

HR HOUR, HUMIDITY RATIO

HW HOT WATER

IAW IN ACCORDANCE WITH

IWG INCHES WATER GAUGE

kW KILOWATT

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LV LOUVER

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MCWB MEAN COINCIDENT WET BLUB

MIN MINIMUM

N NORTH

NC NORMALLY CLOSED, NOISE CRITERIA

NO NUMBER, NORMALLY OPEN

OA OUTSIDE AIR

OAU OUTSIDE AIR UNIT

PH PHASE

PSI POUNDS PER SQUARE INCH

QTY QUANTITY

RA RETURN AIR

RH RELATIVE HUMIDITY

SA SUPPLY AIR

SIM SIMILAR

SP STATIC PRESSURE

SQ SQUARE

TA TRANSFER AIR

TYP TYPICAL

UH UNIT HEATER

UOI UNLESS OTHERWISE INDICATED

V VOLTS

VAV VARIABLE AIR VOLUME

VFD VARIABLE FREQUENCY DRIVE

W WIDTH, WEST

WB WET BULB

WPD WATER PRESSURE DROP

MECHANICAL ABBREVIATIONS

T

HUMIDITY SENSORH

THERMOSTAT

ROUND DUCT DIMENSION

RECTANGULAR DUCT DIMENSIONS (INCHES)

FLEXIBLE ROUND DUCT (5'-0" MAX LENGTH)

12x10

12"Ø

SUPPLY DUCT DOWN/UP

DOWNWARD DIRECTION OF SLOPED PIPING

RETURN DUCT DOWN/UP

GLOBE VALVE

GATE VALVE

BUTTERFLY VALVE

CHECK VALVE

PRESSURE REDUCING VALVE

DRAIN VALVE WITH HOSE CONNECTION

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

BACKFLOW PREVENTER

RELIEF VALVE

MANUAL AIR VENT

AUTOMATIC AIR VENT

WYE STRAINER

STRAINER WITH BLOWDOWN VALVE

CLEAN OUT

PIPE REDUCER

ECCENTRIC REDUCER

UNION

PRESSURE GAUGE WITH SHUTOFF COCK

THERMOMETER

PIPE CAP

FLANGE

FLEXIBLE PIPE CONNECTOR

C.O.

EXHAUST DUCT DOWN/UP

M

M

MV

AV

R/D RISE (R) DROP (D) IN DIRECTION OF FLOW

ACCESS DOOR (AD), ACCESS PANEL (AP)

FIRE DAMPER

AD

FIRE /SMOKE DAMPER

SMOKE DAMPER

BD

BACKDRAFT DAMPER

AIRFLOW MEASURING STATION

OPEN/CLOSED CONTROL DAMPER, PARALLEL

BLADE, MOTOR OPERATED

MODULATING CONTROL DAMPER, OPPOSED

BLADE, MOTOR OPERATED

MANUAL BALANCE DAMPER

AFMS

ATFP EMERGENCY SHUTDOWN SWITCHESS

MANUAL CALIBRATED BALANCING VALVE

MECHANICAL LEGEND

BALL VALVE

DIFFERENTIAL PRESSURE SENSOR

DP

STATIC PRESSURE SENSOR

SP

PIPING TO BE REMOVED

CHILLED WATER SUPPLY PIPING

CHILLED WATER RETURN PIPING

CONDENSATE DRAIN PIPING

HOT WATER SUPPLY PIPING

HOT WATER RETURN PIPING

CHWR

CHWS

D

HHWR

HHWS

MECHANICAL PIPING LEGEND

POINT OF CONNECTION

POINT OF DISCONNECTION

CONSTRUCTION INTERFACE

DEMO

WORK

EXISTING

TO REMAIN

WORK EXISTING

TO REMAIN

EXISTING TO REMAIN

DEMO WORK

WORK

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

DETAIL NUMBER

SCALE

SHEET

REFERENCED

FROM

SECTION TAG

SECTION NUMBER

SHEET WHERE DRAWN

GENERAL PROJECT SYMBOLS

KEYNOTE TAG

KEYNOTE NUMBER

? PHOTOGRAPH TAG

PHOTOGRAPH NUMBER

SHEET WHERE SHOWN

PLAN

NORTH

SCALE

SHEET

REFERENCED

FROM

AIR DISTRIBUTION DEVICE

IDENTIFICATION

EQUIPMENT

IDENTIFICATION

VAV - XX

EQUIPMENT

TYPE

EQUIPMENT

NUMBER

175 CFM

#Ø SA-# (?)

QTY

MARK

AIR FLOW

NECK SIZE

38.85 N

LONGITUDE:

ELEVATION:

LATITUDE:

SUMMER DESIGN WET BULB (1%):

SUMMER DESIGN DRY BULB (1%):

WINTER DESIGN DRY BULB (99%):

STANDARD OUTDOOR DESIGN CONDITIONS:

21°F

75°F 92°F

77.04 W

15 FT.

HVAC DESIGN CRITERIA

LOCATION: WASHINGTON, DC

STATION ID# ICAO_KDCA

SUMMER

DESIGN DRY

BULB:

WINTER

DESIGN DRY

BULB:

STANDARD INDOOR DESIGN CONDITIONS:

78°F 50% RH 68°F NC*

SUMMER

DESIGN

HUMIDITY:

TYPICAL SPACES: OFFICES,

CONFERENCE ROOMS, ETC.

ROOM TYPE:

LAB SPACES 75°F 50% RH 68°F NC*

*UC - UNCONTROLLED

*NC - HUMIDITY NOT DIRECTLY CONTROLLED

WINTER

DESIGN

HUMIDITY:

CLIMATE ZONE 4A

1% HR/MCWB WET BLUB

1% HR/MCWB DRY BLUB

77°F 83°F

CEILING SUPPLY AIR DEVICE

CEILING RETURN AIR DEVICE

CEILING EXHAUST AIR DEVICE

LINEAR SLOT SUPPLY

SURFACE MOUNTED SUPPLY GRILLE

SURFACE MOUNTED RETURN/EXHAUST GRILLE

MECHANICAL LEGEND (CONT.)

LINEAR SLOT RETURN

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

M-001

U S

U -7

P

E R

F O

R M

D E

S

IG

N O

F H

V A

C

LE

G

E N

D , A

B B

R E

V

IA

TI

O

N S

A N

D N

O

TE

S

FYA

13142650

KEL KEL

10/28/2021

1704503

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

SHEET KEYNOTES

8 97653 421

L

J

I

H x6

E A

22x10 EA 30x18 EA x1

E

A

12x8 EA x1

E

A

A2051

10x12 SA

22x16 SA x1

S

A

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA 10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

A2052 A2053 A2054

A2048

A2050

A2047

A2046

A2040

A2041

A2045

A2037

SA3

A2057

A2061

A2065

A2066

A2064

A2063

A2062

A2060

A2058

A2056

A2055A

A2055

14x12 SA

22x16 SA

16x12 SA

10x12 SA

10x12 SA

10x10 SA

20x10 SA

10x10 SA

8x

S A

20x10 SA

20x8 SA

10x10 SA10x10 SA

8x8 SA

10x10 SA

8x8 SA

10x10 SA

8x8 SA

20x16 SA

6x6 SA x1

S

A 8x8 SA

8x8 SA

8x8 SA

8x8 SA

8x8 SA

8x8 SA

8x8 SA

10x8 SA

14x12 SA

10x10 SA x2

S

A x3

S A

8x8 SA

6x8 SA

14x8 SA x2

S

A

10x10 SA

10x10 SA x1

S

A

10x8 SA

8x10 SA

8x8 SA

6x8 SA

6x8 SA

UP TO

EF-2

SUPPLY AIR

SHAFT FROM

AHU-2 & -3

SUPPLY AIR

SHAFT FROM

AHU-9 & -10

16x14 SA

12x12 SA

8x12 SA

CAV-206 (E)

VAV-204 (E)

CAV-203 (E)

CAV-202 (E)

VAV-207A (E)

VAV-207B (E)

CAV-211 (E)

CAV-2C01 (E)

CAV-2C06 (E)

VAV-213A (E)

VAV-213B (E)

VAV-217A (E)

VAV-217B (E)

CAV-2C02 (E)

VAV-218 (E)

VAV-219 (E)

VAV-220 (E)

VAV-221 (E)

VAV-222 (E)

VAV-223 (E)

VAV-224 (E)

VAV-225 (E)

VAV-226 (E)

VAV-212 (E)

10x6 EA

17X17

UP TO

LVL 3

ER HOOD (E)

750 CFM

CAV-208A (E)

8x8 SA

8x8 SA

24x20 SA x2

S

A x2

S A

48x36 SA

24x20 SA x2

S

A x2

S A

CAV-214A (E)

CAV-214B (E)

10x8 SA

12x8 EA

CAV-215A (E)

x1

E

A x1

E A x1

E

A

12x8 EA x2

E

A

CAV-215B (E)

CAV-216A (E)

CAV-216B (E)

12x8 EA

A2049 x1

E

A

34x18 EA 38x18 EA x1

E

A x1

E A

12x10 EA

12x10 EA x1

E

A x1

S

A

8x12 SA

8x10 SA

A2071

A2902

10x8 SA

CAV-208B (E)

TYP.

CAV-209A (E)

CAV-209B (E) TYP.

CAV-210B (E)

CAV-210A (E)

TYP.

TYP.

TYP.

TYP.

A2903

CAV-205 (D)

VAV-201 (D)

MATCHLINE SEE SHEET MD101B

19 12x10 EA

1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

MD101A

U S

U -7

P

E R

F O

R M

D E

S

IG

N O

F H

V A

C

S E

C O

N D

F

LO

O R

A R

E A

A

D E

M O

LI

TI

O N

D

U C

TW

O

R K

P

LA

N

FYA

13142651

KEL KEL

10/28/2021

1704503

1 REMOVE CAV BOX, DUCTWORK, ASSOCIATED SUPPORTS, CONTROLS WIRING,

INSULATION AND APPURTENANCES.

2 REMOVE VAV BOX, DUCTWORK, ASSOCIATED SUPPORTS, CONTROLS WIRING,

INSULATION AND APPURTENANCES.

5 DEMOLISH DUCT INCLUDING INSULATION, HANGERS, AND ASSOCIATED AIR

TERMINALS.

19 DEMOLISH DUCTWORK TO POINTS INDICATED.

23 EXISTING TERMINAL UNIT AND ASSOCIATED DUCTWORK, CONTROLS, AND

APPURTENANCES TO REMAIN. PROTECT DURING CONSTRUCTION.

4' 8' 16'0'

PLAN

NORTH

PLAN

NORTH

A

B

D

C

RM. NUMBER RM. NAME RM. SERVED BY

A2037 JANITOR AHU-2 & -3

A2040 LAB AHU-2 & -3

A2041 CLASSROOM AHU-2 & -3

A2045 CLASSROOM AHU-2 & -3

A2046 OPEN OFFICE AHU-2 & -3

A2047 OPEN OFFICE AHU-2 & -3

A2048 OPEN OFFICE AHU-2 & -3

A2049 CLASSROOM AHU-2 & -3

A2050 LAB AHU-2 & -3

A2051 OPEN OFFICE AHU-2 & -3

A2052 CONFERENCE ROOM AHU-2 & -3

A2053 CONFERENCE ROOM AHU-9 & -10

A2054 STORAGE AHU-9 & -10

A2055 OFFICE AHU-9 & -10

A2055A OFFICE AHU-9 & -10

A2056 OFFICE AHU-9 & -10

A2057 CLASSROOM AHU-9 & -10

A2058 OFFICE AHU-9 & -10

A2060 OFFICE AHU-9 & -10

A2061 CLASSROOM AHU-9 & -10

A2062 OFFICE AHU-9 & -10

A2063 OFFICE AHU-9 & -10

A2064 OPEN OFFICE AHU-9 & -10

A2065 CLASSROOM AHU-9 & -10

A2066 OPEN OFFICE AHU-9 & -10

A2071 UTILITY CHASE AHU-2, -3, -9, & -10

A2901 CORRIDOR AHU-9, -10, -12, & -13

A2902 CORRIDOR AHU-2, -3, -5, & -6

A2903 CORRIDOR AHU-2, -3, -9, & -10

1/8" = 1'-0" A1

SECOND FLOOR AREA A - DEMOLITION - DUCTWORK PLAN

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

E

H

G

F

16x8 EA

18x12 EA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

MATCHLINE SEE SHEET MD101A

SA2 44

A2031

A2032

A2033

A2034

A2035

A2007A

A2002

A2004

A2006

A2074

A2068

A2067

A2039

A2070

A2069

10x8 SA x1

S

A

8x10 SA

6x8 SA

6x8 SA

28x8 SA

30x12 RA x1

S

A

8x6 SA

14x12 SA x3

S

A

8x

S A

16x14 SA10x12 SA

14x12 SA

8x12 SA 6x

S

A

6x

S A

6x

S A

8x10 SA

8x10 SA

6x8 SA x2

S

A x2

S A x1

S

A

10x8 SA

8x10 SA

10x10 SA

20x14 SA x1

S

A

12x10 SA

12x10 SA 12x12 SA x1

S

A

8x8 SA6x8 SA

8x

S A

10x10 SA x1

S

A x2

S A x1

S

A x1

S A

18x10 SA 6x10 SA

8x

E A

12x10 SA

18x12 EA

6x

S A

16x10 SA

10x10 SA

8x8 EA

UP TO

EF-4

UP TO

EF-6

UP TO

EF-12

UP TO

EF-13

SUPPLY AIR

SHAFT FROM

AHU-5 & -6

10x12 SA

VAV-237 (E)

CAV-234 (E)

VAV-238 (E)

CAV-235 (E)

CAV-235A (E)

CAV-235B (E)

CAV-235C (E)

VAV-241 (E)

VAV-240 (E)

VAV-239 (E)

CAV-2C05A (E)

CAV-2C05B (E)

CAV-2C05D (E)

6x8 SA

VAV-227A (E)

VAV-227B (E)

VAV-236 (E)

CAV-231 (E)

CAV-2C04 (E)

VAV-229 (E)

CAV-228 (E)

CAV-2C05E (E)

CAV-2C03A (E)

A2904

A2071A

12ø EA

UP TO

EF-29

x8

E A

10ø UP

TO LVL

CAV-233B (E)

CAV-230B (E)

CAV-230A (E)

12x10 EATYP.

CAV-233A (E)

12x8 EA TYP.

CAV-232A (E)

CAV-232B (E)

12x8 EA TYP.

A2902

A2012

8x6 EA

8x

S A

MATCHLINE SEE SHEET MD101D

A2007B A2007C

A2007

A2071 x1

E

A x1

E

A

1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

MD101B

U S

U -7

P

E R

F O

R M

D E

S

IG

N O

F H

V A

C

S E

C O

N D

F

LO

O R

A R

E A

B

D E

M O

LI

TI

O N

D

U C

TW

O

R K

P

LA

N

FYA

13142652

KEL KEL

10/28/2021

1704503

19 DEMOLISH DUCTWORK TO POINTS INDICATED.

4' 8' 16'0'

PLAN

NORTH

PLAN

NORTH

A

B

D

C

RM. NUMBER RM. NAME RM. SERVED BY

A2002 OFFICE AHU-12 & -13

A2004 OFFICE AHU-12 & -13

A2006 OFFICE AHU-12 & -13

A2007 LAB AHU-12 & -13

A2007A OFFICE AHU-12 & -13

A2007B OFFICE AHU-12 & -13

A2007C OFFICE AHU-12 & -13

A2012 UTILITY CHASE AHU-5, -6, -12, -13

A2031 CLASSROOM AHU-5 & -6

A2032 ALCOVE AHU-5 & -6

A2033 LAB AHU-5 & -6

A2034 OPEN OFFICE AHU-2 & -3

A2035 LAB AHU-5 & -6

A2039 CLASSROOM AHU-2 & -3

A2067 OPEN OFFICE AHU-9 & -10

A2068 OFFICE AHU-12 & -13

A2069 CLASSROOM AHU-9 & -10

A2070 STORAGE AHU-12 & -13

A2071 UTILITY CHASE AHU-2, -3, -9, & -10

A2074 CONFERENCE ROOM AHU-12 & -13

A2901 CORRIDOR AHU-9, -10, -12, & -13

A2902 CORRIDOR AHU-2, -3, -5, & -6

A2904 CORRIDOR AHU-5 & -6

1/8" = 1'-0" A1

SECOND FLOOR AREA B - DEMOLITION - DUCTWORK PLAN

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

E

D

C

B

A x1

E

A

36x16 EA 10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

10x12 SA

MATCHLINE SEE SHEET MD101B

A2019

A2020A

A2020

A2020B

A2024

A2027

A2030

A2029

A2025

A2021 A2017

A2013

A2009

A2010

A2008

A2011

A2015

6x

S A

16x16 SA 16x14 SA 10x14 SA x3

S

A

8x8 SA x1

S

A x2

S A

8x8 SA

8x8 SA x2

S

A

8x

S A x2

S

A x3

S A

8x8 SA 8x8 SA

12x6 SA x8

E A

10x8 SA

12x6 SA

30x14 EA

8x8 SA

10x10 SA

8x

S A

8x10 SA

8x8 SA

8x8 SA x1

E

A

16x4 EA

16x6 EA x4

E A

38X18

EA UP

TO

EF-8

22X12 EA

FROM

GROUND

LEVEL

SUPPLY AIR

SHAFT FROM

AHU-12 & -13

FCU-001 (E)

VAV-259 (E)

VAV-260 (E)

VAV-261A (E)

VAV-261B (E)

VAV-262 (E)

CAV-255 (E)

8x8 SA

VAV-2C08 (E)

VAV-249 (E)

VAV-242A (E)

VAV-242B (E)

VAV-244 (E)

VAV-245 (E)

VAV-246 (E)

VAV-247 (E)

VAV-248 (E)

CAV-254 (E)

VAV-250 (E)

x1

E

A

CAV-2C03B (E)

A2905

CAV-258B (E)

CAV-258A (E)

CAV-257B (E)

CAV-257A (E)

CAV-256B (E)

CAV-256A (E)

6x

S

A

CAV-253B (E)

10x12 SACAV-253A (E)

CAV-253C (E)

A2021E

CAV-252B (E)

CAV-252A (E)

x1

E

A

CAV-251B (E)

CAV-251A (E)

x8

S A

12x8 EA TYP.

12x8 EA TYP.

12x8 EA TYP.

A2012

12x8 EA TYP.

8x

S A

TYP.

19 19

1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

MD101D

U S

U -7

P

E R

F O

R M

D E

S

IG

N O

F H

V A

C

S E

C O

N D

F

LO

O R

A R

E A

D

D E

M O

LI

TI

O N

D

U C

TW

O

R K

P

LA

N

FYA

13142653

KEL KEL

10/28/2021

1704503

19 DEMOLISH DUCTWORK TO POINTS INDICATED.

23 EXISTING TERMINAL UNIT AND ASSOCIATED DUCTWORK, CONTROLS, AND

APPURTENANCES TO REMAIN. PROTECT DURING CONSTRUCTION.

4' 8' 16'0'

PLAN

NORTH

PLAN

NORTH

A

B

D

C

RM. NUMBER RM. NAME RM. SERVED BY

A2008 CONFERENCE ROOM AHU-12 & -13

A2009 CLASSROOM AHU-12 & -13

A2010 OPEN OFFICE AHU-12 & -13

A2011 CONFERENCE ROOM AHU-12 & -13

A2012 UTILITY CHASE AHU-5, -6, -12, -13

A2013 CLASSROOM AHU-12 & -13

A2015 CONFERENCE ROOM AHU-12 & -13

A2017 CLASSROOM AHU-12 & -13

A2019 OFFICE AHU-5 & -6

A2020 OFFICE AHU-5 & -6

A2020A OFFICE AHU-5 & -6

A2020B OFFICE AHU-5 & -6

A2021 CLASSROOM AHU-5 & -6

A2021E STORAGE AHU-5 & -6

A2024 OFFICE AHU-5 & -6

A2025 CLASSROOM AHU-5 & -6

A2027 OFFICE AHU-5 & -6

A2028 OFFICE AHU-5 & -6

A2029 CLASSROOM AHU-5 & -6

A2030 OPEN OFFICE AHU-5 & -6

A2901 CORRIDOR AHU-9, -10, -12, & -13

A2902 CORRIDOR AHU-2, -3, -5, & -6

A2905 CORRIDOR AHU-5 & -6

1/8" = 1'-0" A1

SECOND FLOOR AREA D - DEMOLITION - DUCTWORK PLAN

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

/2

1/

L

J

I

H

A3045

A3046

A3047

A3050

A3053

A3043

A3049

A3079

A3076

A3072

A3062

A3066

A3068

A3069 A3063A3064A3058

A3056

A3059

A3S3 A3051

A3070

A3071

A3073

A3074

A3075

A3077

A3078

A3080 x1

S

A 8x

10x10

14x12 SA

6x6 SA 6x6 SA

8x8 SA

8x

S A

9x10 SA

6x8 SA

6x10 SA

8x8 SA

8x10 SA x1

S

A

8x10 SA

8x6 SA 8x6 SA

12x10 SA

8x10 SA

A3048

8x8 SA x1

S

A

8x8 SA x1

S

A x2

S A

8x8 SA

8x8 SA

8x8 SA

8x8 SA

8x10 SA

8x8 SA

10x12 SA8x10 SA

18x12 SA

10x12 SA x3

S

A x1

S A x3

S

A

12x14 SA8x12 SA

12x14 SA

12x12 SA

10x12 SA 14x14 SA

10x12 SA

14x14 SA

48x36 SA x3

S

A x3

S A x1

S

A x1

S

A x1

S

A

14x8 SA

48x32 SA x2

S

A x1

S A

10x14 SA

14x14 12x14 x1

14x14

10x12

20x10 SA

14x14 12x14 x1

14x14

16x14 SA x1

S

A x1

S

A x1

S

A10x12 SA

22x12 SA

14x14 SA 10x12 SA

10x12 SA

6x8 SA

10x10 SA

12x16 SA

6x10

8x

S A

8x

S A x2

S

A

8x6

8x8

8x

S A

8x

S A

8x10 SA

8x

S A

14x12 SA

8x8 SA

8x

S A

8x

S A x1

S

A x1

S A x1

E

A x1

E

A x1

E A x3

E

A x1

E

A x1

E A x1

E

A

SUPPLY AIR

SHAFT FROM

AHU-2 & -3

SUPPLY AIR

SHAFT FROM

AHU-9 & -10

18x14 EA

40X40

EA UP

TO EF-1

DOWN TO

LEVEL 2

40X18 EA

UP TO

EF-2

38x48 EA

UP TO EF-9

76X24 EA

DOWN TO

LEVEL 2

FCU-002

FCU-003

FCU-004

VAV-316B (E)

CAV-316A (E)

CAV-314 (E)

CAV-317B (E)

CAV-317A (E)

CAV-313A (E)

A3060

VAV-305 (E)

VAV-302 (E)

VAV-304A (E)

VAV-304B (E)

VAV-304C (E)

CAV-320 (E)

CAV-3C03A (E)

CAV-3C03B (E)

CAV-3C01 (E)

VAV-303 (E)

CAV-324B (E)

CAV-321 (E)

CAV-324A (E)

CAV-323B (E)

CAV-323A (E)

CAV-322B (E)

CAV-322A (E)

CAV-3C02 (E)

VAV-310 (E)

VAV-309 (E)

VAV-307 (E)

VAV-308 (E)

VAV-306 (E)

CAV-3C04B (E)

CAV-3C04A (E)

VAV-311 (E)

VAV-312 (E)

VAV-325 (E)

VAV-326 (E)

VAV-327 (E)

VAV-328 (E)

VAV-329 (E)

VAV-330 (E)

VAV-331 (E)

VAV-332 (E)

17X17

UP TO

EF-24

12ø UP

TO

EF-25

8x12 SA

A3057 x1

S

A

A3061A A3061B

8x6 SA

A3067 x1

S

A

A3903

A3086

CAV-318A (D)

CAV-318B (D)

CAV-315 (D)1

VAV-313B (D)

VAV-301 (D)

1 0x 12

CAV-319B (D) 1

CAV-319A (D)

MATCHLINE SEE SHEET MD102B

A3042D A3042C

A3042

1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

NOTES.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 31 JANUARY 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

A

T L A

N T

IC

W

A S

H

IN

G T

O N

N A

V Y

Y A

R D

W A

S H

IN

G

T O

N D

.C

B. JAEGER, P.E.

U N

IF

O

R M

E D

S E

R V

IC

E

U N

IV

E

R S

IT

Y

B E

T H

E S

D A

M

A R

Y L A

N D

AS NOTED

KEY PLAN

SHEET NOTES

MD102A

U S

U -7

P

E R

F O

R M

D E

S

IG

N O

F H

V A

C

TH

I…

This is the start of the file's text. The full file is on GovTribe.