Attachment F BLDG70-USU_Final-Design-Drawings.pdf
PDF 22 MB Posted
- Solicitation number
- N4008024R2396
About this file
This document appears to be Attachment F BLDG70-USU_Final-Design-Drawings, which is related to the Indefinite-Delivery, Indefinite-Quantity (IDIQ) Multiple Award Construction Contract (MACC) for Mechanical projects primarily in the NAVFAC Washington Area of Responsibility (AOR) or any other location by agreement of Contractor and Government, Solicitation Number N4008024R2396.
The attachment contains final design drawings for BLDG70-USU. The solicitation is for an IDIQ MACC contract for mechanical projects primarily in the NAVFAC Washington AOR. The contract will be awarded to multiple contractors. The work may be performed at any location by agreement between the contractor and the government. Relevant agencies include the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
G-001
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
B U
IL
D
IN
G
P E
R F
O R
M D
E S
IG
N
F O
R H
V A
C
C O
V E
R S
H E
E T
SM
13142640
WC MR
1704503
BUILDING 70
VICINITY MAP LOCATION MAP
USU - 70 PERFORM
DESIGN FOR HVAC
BETHESDA, MARYLAND
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND MID-ATLANTIC
UNIFORMED SERVICES UNIVERSITY OF THE HEALTH SERVICES
WASHINGTON, D.C.
04/21/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
/2 mwrider Image
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
G-002
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
B U
IL
D
IN
G
IN
D E
X O
F D
R A
W
IN
G S
SM
13142641
WC MR
1704503
INDEX OF DRAWING
SHEET OF NAVFAC_NO SHEET NUMBER SHEET TITLE
ELECTRICAL
71 13142710 E-001 LEGEND, ABBREVIATIONS AND GENERAL NOTES
72 13142711 ED101A ELECTRICAL DEMOLITION - SECOND FLOOR - AREA A
73 13142712 ED101B ELECTRICAL DEMOLITION - SECOND FLOOR - AREA B
74 13142713 ED101D ELECTRICAL DEMOLITION - SECOND FLOOR - AREA D
75 13142714 ED102A ELECTRICAL DEMOLITION - THIRD FLOOR - AREA A
76 13142715 ED102B ELECTRICAL DEMOLITION - THIRD FLOOR - AREA B
77 13142716 ED102D ELECTRICAL DEMOLITION - THIRD FLOOR - AREA D
78 13142717 E-101A ELECTRICAL - SECOND FLOOR - AREA A
79 13142718 E-101B ELECTRICAL - SECOND FLOOR - AREA B
80 13142719 E-101D ELECTRICAL - SECOND FLOOR - AREA D
81 13142720 E-102A ELECTRICAL - THIRD FLOOR - AREA A
82 13142721 E-102B ELECTRICAL - THIRD FLOOR - AREA B
83 13142722 E-102D ELECTRICAL - THIRD FLOOR - AREA D
84 13142723 E-103C ELECTRICAL - ROOF FLOOR - AREA C
85 13142724 E-601 PANELBOARD SCHEDULES
INDEX OF DRAWING
SHEET OF NAVFAC_NO SHEET NUMBER SHEET TITLE
GENERAL
1 13142640 G-001 BUILDING 70 PERFORM DESIGN FOR HVAC - COVER SHEET
2 13142641 G-002 BUILDING 70 - INDEX OF DRAWINGS
ARCHITECTURAL
3 13142642 A-001 ARCHITECTURAL SYMBOLS, LEGENDS, ABBREVIATIONS AND NOTES
4 13142643 A-101A SECOND FLOOR RCP - AREA A
5 13142644 A-101B SECOND FLOOR RCP - AREA B
6 13142645 A-101D SECOND FLOOR RCP - AREA D
7 13142646 A-102A THIRD FLOOR RCP - AREA A
8 13142647 A-102B THIRD FLOOR RCP - AREA B
9 13142648 A-102D THIRD FLOOR RCP - AREA D
10 13142649 A-901 PHOTOGRAPHS
MECHANICAL
11 13142650 M-001 LEGEND, ABBREVIATIONS AND NOTES
12 13142651 MD101A SECOND FLOOR AREA A - DEMOLITION - DUCTWORK PLAN
13 13142652 MD101B SECOND FLOOR AREA B - DEMOLITION - DUCTWORK PLAN
14 13142653 MD101D SECOND FLOOR AREA D - DEMOLITION - DUCTWORK PLAN
15 13142654 MD102A THIRD FLOOR AREA A - DEMOLITION - DUCTWORK PLAN
16 13142655 MD102B THIRD FLOOR AREA B - DEMOLITION - DUCTWORK PLAN
17 13142656 MD102D THIRD FLOOR AREA D - DEMOLITION - DUCTWORK PLAN
18 13142657 MD103A MEZZANINE FLOOR AREA A - DEMOLITION - PIPING PLAN
19 13142658 MD103B MEZZANINE FLOOR AREA B - DEMOLITION - PIPING PLAN
20 13142659 MD103D MEZZANINE FLOOR AREA D - DEMOLTION - PIPING PLAN
21 13142660 MD104A SECOND FLOOR AREA A - DEMOLITION - PIPING PLAN
22 13142661 MD104B SECOND FLOOR AREA B - DEMOLITION - PIPING PLAN
23 13142662 MD104D SECOND FLOOR AREA D - DEMOLITION - PIPING PLAN
24 13142663 MD105A THIRD FLOOR AREA A - DEMOLITION - PIPING PLAN
25 13142664 MD105B THIRD FLOOR AREA B - DEMOLITION - PIPING PLAN
26 13142665 MD105D THIRD FLOOR AREA D - DEMOLITION - PIPING PLAN
27 13142666 MH101A MEZZANINE FLOOR AREA A - DUCTWORK PLAN
28 13142667 MH101B MEZZANINE FLOOR AREA B - DUCTWORK PLAN
29 13142668 MH101D MEZZANINE FLOOR AREA D - DUCTWORK PLAN
30 13142669 MH102A SECOND FLOOR AREA A - DUCTWORK PLAN
31 13142670 MH102B SECOND FLOOR AREA B - DUCTWORK PLAN
32 13142671 MH102C SECOND FLOOR AREA C - DUCTWORK PLAN
33 13142672 MH102D SECOND FLOOR AREA D - DUCTWORK PLAN
34 13142673 MH103A THIRD FLOOR AREA A - DUCTWORK PLAN
35 13142674 MH103B THIRD FLOOR AREA B - DUCTWORK PLAN
36 13142675 MH103C THIRD FLOOR AREA C - DUCTWORK PLAN
37 13142676 MH103D THIRD FLOOR AREA D - DUCTWORK PLAN
38 13142677 MI101A SECOND FLOOR AREA A - INSTRUMENTATION PLAN
39 13142678 MI101B SECOND FLOOR AREA B - INSTRUMENTATION PLAN
40 13142679 MI101C SECOND FLOOD AREA C - INSTRUMENTATION PLAN
41 13142680 MI101D SECOND FLOOR AREA D - INSTRUMENTATION PLAN
42 13142681 MI102A THIRD FLOOR AREA A - INSTRUMENTATION PLAN
43 13142682 MI102B THIRD FLOOR AREA B - INSTRUMENTATION PLAN
44 13142683 MI102C THIRD FLOOR AREA C - INSTRUMENTATION PLAN
45 13142684 MI102D THIRD FLOOR AREA D - INSTRUMENTATION PLAN
46 13142685 MP101A MEZZANINE FLOOR AREA A - PIPING PLAN
47 13142686 MP101B MEZZANINE FLOOR AREA B - PIPING PLAN
48 13142687 MP101D MEZZANINE FLOOR AREA D - PIPING PLAN
49 13142688 MP102A SECOND FLOOR AREA A - PIPING PLAN
50 13142689 MP102B SECOND FLOOR AREA B - PIPING PLAN
51 13142690 MP102C SECOND FLOOR AREA C - PIPING PLAN
52 13142691 MP102D SECOND FLOOR AREA D - PIPING PLAN
53 13142692 MP103A THIRD FLOOR AREA A - PIPING PLAN
54 13142693 MP103B THIRD FLOOR AREA B - PIPING PLAN
55 13142694 MP103C THIRD FLOOR AREA C - PIPING PLAN
56 13142695 MP103D THIRD FLOOR AREA D - PIPING PLAN
57 13142696 M-501 MECHANICAL DETAILS
58 13142697 M-601 MECHANICAL SCHEDULES
59 13142698 M-602 MECHANICAL SCHEDULES
60 13142699 M-603 MECHANICAL SCHEDULES
61 13142700 M-604 MECHANICAL SCHEDULES
62 13142701 M-605 MECHANICAL SCHEDULES
63 13142702 MI700 TEMPERATURE CONTROLS LEGEND & ABBREVIATIONS
64 13142703 MI701 MECHANICAL SEQUENCES AND SCHEMATICS
65 13142704 MI702 MECHANICAL SEQUENCES AND SCHEMATICS
66 13142705 M-801 AIRFLOW DIAGRAM AHU 2&3
67 13142706 M-802 AIRFLOW DIAGRAM AHU 5&6
68 13142707 M-803 AIRFLOW DIAGRAM AHU 9&10
69 13142708 M-804 AIRFLOW DIAGRAM AHU 12&13
70 13142709 M-805 HOT WATER FLOW DIAGRAM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
ARCHITECTURAL SYMBOLS
SPECIALTY ITEM NUMBER
SPECIALTY ITEM TAG
MATCHLINE
MATCHLINE SEE SHEET A-###
1. WORK MUST COMPLY WITH APPLICABLE CODES AND STANDARDS AS
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
2. DIMENSIONS GOVERN. DETAILS GOVERN OVER PLANS AND
ELEVATIONS. LARGE SCALE DETAILS OR PLANS GOVERN OVER
SMALL SCALE DETAILS OR PLANS. DO NOT SCALE DRAWINGS.
3. ANY MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR
SPECIFIED ARE DONE SO TO ESTABLISH A MINIMUM LEVEL OF
QUALITY.
4. CONSTRUCTION MUST MEET OR EXCEED LOCAL INDUSTRY
STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM
QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION.
INCORPORATE SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS
NOTED OTHERWISE.
5. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,
SECTIONS OR ELEVATIONS.
6. BRACE SUSPENDED CEILINGS, SUSPENDED ITEMS, ETC. ONLY TO
STRUCTURAL ELEMENTS ABOVE. DO NOT ANCHOR TO ROOF DECK,
PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT
OR SIMILAR ELEMENTS.
7. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED
FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS
SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE
CONTRACTOR.
8. BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE
WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE
ACTUAL CONDITIONS MUST BE REPORTED TO THE CONTRACTING
OFFICER FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
9. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS
UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE
CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE
PROPER AND TIMELY EXECUTION OF THE INSTALLERS WORK. DO
NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
CORRECTED. INSTALLATION CONSTITUTES ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
10. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS MEANS THAT THE
CONDITIONS OR DIMENSION IS THE SAME OR REPRESENTATIVE FOR
SIMILAR CONDITIONS THROUGHOUT.
11. PRIOR TO BEGINNING ANY WORK, NOTIFY CONTRACTING OFFICER
OF ANY EXISTING MATERIALS OBSERVED TO POSSIBLY CONTAIN
ASBESTOS.
12. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO
ACCOMPLISH NEW WORK.
13. PROTECT EXISTING WORK TO REMAIN. PERFORM CUTTING TO
ACCOMPLISH REMOVALS NEATLY AND AS SPECIFIED FOR CUTTING
NEW WORK. REPAIR ADJACENT CONSTRUCTIO, WALLS AND FINISHES
DAMAGED DURING REMOVAL WORK. PATCH AS SPECIFIED FOR
PATCHING NEW WORK.
14. "EXISTING" INFORMATION ON THE CONTRACT DOCUMENTS HAS BEEN
OBTAINED FROM A PREVIOUS SET OF DRAWINGS, OR FROM FIELD
INVESTIGATION AND SUCH "EXISTING" INFORMATION MUST BE FIELD
VERIFIED.
15. COORDINATE WITH THE CONTRACTING OFFICER FOR DESIGNATED
CONSTRUCTION STAGING LOCATIONS, STORAGE AREAS, AND
CONSTRUCTION SEQUENCING.
16. THE PREMISES WILL BE OCCUPIED DURING THE CONSTRUCTION
SCHEDULE. COORDINATE WITH THE CONTRACTING OFFICER
REGARDING INTERRUPTIONS OF UTILITIES, TEMPORARY EXITS, DUST
PARTITIONS, DELIVERIES, AND OTHER JOB REQUIREMENTS.
17. CARE SHOULD BE MADE TO KEEP DUST AND NOISE FROM
DEMOLITION ACTIVITIES FROM THE OTHER PORTIONS AND FLOORS
OF THE BUILDING. ERECT AND MAINTAIN DUSTPROOF PARTITIONS.
COVER AND PROTECT FURNITURE, FURNISHINGS AND EQUIPMENT
THAT HAVE NOT BEEN REMOVED.
18. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION
REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO
ADJACENT BUILDING AREAS TO REMAIN.
ROOM NAME
A1 A-101
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
A101 INTERIOR ELEVATION
TAG
INTERIOR ELEVATION NUMBER
SHEET WHERE DRAWN
DETAIL NUMBER
SCALE
SHEET
REFERENCED FROM
EXTERIOR ELEVATION
TAG
ELEVATION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
A1 A-101
WALL / PARTIAL
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
A1 A-101
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
A1 A-101
BUILDING
KEYNOTE TAG
KEYNOTE NUMBER
A101 PHOTOGRAPH TAG
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
A1
SCALE
A-101 A1
OH
A1.
A1
A1.
A1.
A1
DETAIL TITLE
1/8" = 1'-0" (A-101) A1
DETAIL TITLE
1/8" = 1'-0" (A-101)
SHEET
REFERENCED FROM
PLAN
NORTH
MATERIALS LEGEND
2' x 2' ACOUSTICAL CEILING TILE
10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR
HVAC AIR SUPPLY GRILLE
HVAC EXHAUST OR RETURN GRILLE
HVAC LINEAR AIR SUPPLY GRILLE
EXPOSED CEILING
1' x 4' LED EMERGENCY FIXTURE -
SUSPENDED
EXIT SIGN
1' x 4' LED FIXTURE - SUSPENDED
2' x 4' LED EMERGENCY FIXTURE -
RECESSED
2' x 4' LED FIXTURE - RECESSED
2' x 2' LED FIXTURE - RECESSED
2' x 4' ACOUSTICAL CEILING TILE
GYPSUM CEILING
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
A-001
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
A R
C H
IT
E
C T
U R
A L
S Y
M B
O
LS
, L E
G E
N D
S , A
B B
R E
V
IA
T
IO
N S
A N
D N
O
TE
S
EV
13142642
WMC WMC
1704503
ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL GENERAL NOTES
PLYWD PLYWOOD
PROJ PROJECT
PVC POLYVINYL CHLORIDE
-R-
R RADIUS
RCP REFLECTIVE CEILING PLAN
RD ROOF DRAIN
RECP RECEPTACLE (ASK INT)
REFER REFERENCE
REINF REINFORCED
REQ'D REQUIRED
REV REVISION
RO ROUGH OPENING
-S-
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SID STRUCTURAL INTERIOR DESIGN (ASK
INT)
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE, AS IN "SQ FT"
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL
SUPP SUPPORT
SUSP SUSPENDED
SYS SYSTEM
-T-
TD TRENCH DRAIN
TECH TECHNICAL
THRU THROUGH
TLT TOILET
TO TOP OF, AS IN "TO STEEL"
TYP TYPICAL
-U-
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
-V-
VENT VENTILATE, VENTILATOR
VERT VERTICAL
VOL VOLUME
-W-
W WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WT WEIGHT
FP FIRE PROTECTION
FT FEET / FOOT
-G-
GA GAUGE
GALV GALVANIZED
GL GIRT LINE
GYP GYPSUM
GYP BD /
GWB
GYPSUM BOARD
-H-
H / HT HEIGHT
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HVAC HEATING, VENTILATION & AIR
CONDITIONING
-I-
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
-J-
JAN JANITOR'S CLOSET
-L-
L LEFT, LONG, LENGTH
LAB LABORATORY
LAV LAVATORY
LB or # POUND
LVR LOUVER
-M-
MACH MACHINE
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR /
MNFR
MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
-N-
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
-O-
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
-P-
PERIM PERIMETER
PKG PACKAGE
PL PLATE
PLMB PLUMBING
-A-
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
-B-
BD BOARD
BLDG BUILDING
BO BOTTOM OF, AS IN "BO STEEL"
-C-
CAB CABINET (ASK INT)
CID COMPREHENSIVE INTERIOR DESIGN
(ASK INT)
CJ CONTROL JOINT, CONSTRUCTION
JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CORR CORRUGATED OR CORRIDOR
-D-
DBL DOUBLE
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
-E-
EA EACH
EEW EMERGENCY EYEWASH
EEWS EMERGENCY EYEWASH & SHOWER
EF EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION, AS IN HEIGHT
ELEC /
ELECT
ELECTRIC / ELECTRICAL
ELEV ELEVATOR, OR ELEVATION AS IN
NORTH ELEV
EQ EQUAL
EQUIP EQUIPMENT
ETC AND SO FORTH (ETCETERA)
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
-F-
FD FLOOR DRAIN
FE FIRE EXTINGUISHER WITH WALL
BRACKET
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF&E FURNITURE, FIXTURES & EQUIPMENT
FHC FIRE HOSE CABINET (WITH
EXTINGUISHER & BRACKET)
FHR FIRE HOSE REEL (WITH EXTINGUISHER
& BRACKET)
FIN FINISHED, FINISH
FLR FLOOR
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
1 74
CLASSROOM
A2057
OPEN OFFICE
A2051
CONFERENCE ROOM
A2052
CONFERENCE ROOM
A2053
STORAGE
A2054
LAB
A2050
2 3 5 6 8 9
STAIR
SA3
JAN
A2037
LAB
A2040
OPEN OFFICE
A2046
OPEN OFFICE
A2047
OPEN OFFICE
A2048
OPEN OFFICE
A2066
OPEN OFFICE
A2064
OFFICE
A2063
OFFICE
A2055
OFFICE
A2055A
OFFICE
A2056
OFFICE
A2058
OPEN OFFICE
A2060
OFFICE
A2062
CLASSROOM
A2061
CLASSROOM
A2065
CLASSROOM
A2049
CLASSROOM
A2045
CLASSROOM
A2041
H
I
J
K
L
MATCHLINE SEE SHEET A-101B MATCHLINE SEE SHEET A-101B
CORRIDOR
A2902
UTILITY CHASE
A2071
CORRIDOR
A2903
CORRIDOR
A2901
1 2
A-901 C1
A-901 C1
A-901 C1
A-901C1
A-901C1
A-901C1
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-101A
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
S E
C O
N D
F
LO
O R
R C
P
A R
E A
A
EV
13142643
WMC WMC
1704503
PLAN
NORTH
A
B
D
C
4' 8' 16'0'
PLAN
NORTH
1/8" = 1'-0" A1
SECOND FLOOR CEILING - AREA A
SHEET KEYNOTES
1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER
WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING
TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED
CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING
TILES AND GRIDS WITHIN AREA OF WORK.
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE
NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY
DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%
OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.
SIM
SIM
SIM
SIM
SIM
SIM
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
1 742 3 5 6 8 9
CLASSROOM
A2039
CLASSROOM
A2069
LAB PREP
A2035
STORAGE
A2070
OPEN OFFICE
A2067
OFFICE
A2068
CONFERENCE ROOM
A2074
OPEN OFFICE
A2034
ELEV
ELEV
LAB
A2033
ALCOVE
A2032
ELEV
STAIR
SA2
CLASSROOM
A2031
OFFICE
A2007A
OFFICE
A2002
OFFICE
A2004
OFFICE
A2006
E
F
G
MATCHLINE SEE SHEET A-101A MATCHLINE SEE SHEET A-101A
MATCHLINE SEE SHEET A-101D MATCHLINE SEE SHEET A-101D
M A
T C
H
LI
N E
S E
E S
H E
E T
A -1
C
M A
T C
H
LI
N E
S E
E S
H E
E T
A -1
C
CORRIDOR
A2904
UTILITY CHASE
A2071A
UTILITY CHASE
A2071
UTILITY CHASE
A2012
LAB
A2007
OFFICE
A2007B
OFFICE
A2007C
CORRIDOR
A2901
CORRIDOR
A2901
CORRIDOR
A2902
CORRIDOR
A2901
M A
T C
H
LI
N E
A R
E A
N O
T
IN
S C
O P
E M
A T
C H
LI
N
E A
R E
A N
O T
IN
S
C O
P E
A-901 C1
A-901 C1
A-901C1
A-901 C1
SIM
SIM
SIM
SIM
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-101B
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
S E
C O
N D
F
LO
O R
R C
P
A R
E A
B
EV
13142644
WMC WMC
1704503
PLAN
NORTH
A
B
D
C
1/8" = 1'-0" A1
SECOND FLOOR CEILING - AREA B
4' 8' 16'0'
PLAN
NORTH
SHEET KEYNOTES
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE
NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY
DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%
OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
1 7
C
A
42 3 5 6 8 9
CONFERENCE ROOM
A2008
OPEN OFFICE
A2010
CONFERENCE ROOM
A2011
CONFERENCE ROOM
A2015
CLASSROOM
A2009
CLASSROOM
A2013
CLASSROOM
A2017
CLASSROOM
A2021
CLASSROOM
A2025
CLASSROOM
A2029
OPEN OFFICE
A2030
OFFICE
OFFICE
A2027
OFFICE
A2024
OFFICE
A2020
OFFICE
A2020A
OFFICE
A2020B
OFFICE
A2019
B
D
MATCHLINE SEE SHEET A-101B MATCHLINE SEE SHEET A-101B
CORRIDOR
A2901
CORRIDOR
A2902
UTILITY CHASE
A2012
STORAGE
A2021E
CORRIDOR
A2905
A-901 C1
A-901 C1
A-901C1
A-901C1
A-901C1
SIM
SIM
SIM
SIM
SIM
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-101D
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
S E
C O
N D
F
LO
O R
R C
P
A R
E A
D
EV
13142645
WMC WMC
1704503
1/8" = 1'-0" A1
SECOND FLOOR CEILING - AREA D
PLAN
NORTH
A
B
D
C
4' 8' 16'0'
PLAN
NORTH
SHEET KEYNOTES
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE
NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY
DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%
OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
STAIR
A3S3
JAN
A3051
LAB
A3053
OFFICE
A3059
OPEN OFFICE
A3056
OFFICE
A3058
OFFICE
A3064
OFFICE
A3063
OFFICE
A3062
OFFICE
A3066
CORR
A3065
OPEN OFFICE
A3068
OFFICE
A3069
LAB
A3045
LAB
A3047
LAB
A3049
LAB
A3072
LAB
A3076
LAB
A3079
GLASS-WASHING ROOM
A3043
LAB
A3046
LAB
A3048
LAB
A3050
OFFICE
A3070
OFFICE
A3071
OFFICE
A3073
OFFICE
A3074
OFFICE
A3075
OFFICE
A3077
OPEN OFFICE
A3078
OFFICE
A3080
H
I
J
K
L
MATCHLINE SEE SHEET A-102B MATCHLINE SEE SHEET A-102B
OPEN OFFICE
A3060
UTILITY CHASE
A3086
CORRIDOR
A3901
LAB
A3047C
LAB
A3047B
LAB
A3047A
1 2 1 2 1 2
LAB
A3045A
OFFICE
A3057
OFFICE
A3061A
OFFICE
A3061B
CONFERENCE ROOM
A3067
ELEC
A3087
MECH
A3088
8' - 0" A.F.F.
OFFICE
A3042C OFFICE
A3042D
CORRIDOR
A3042
CORRIDOR
A3902
CORRIDOR
A3902
CORRIDOR
A3903
A-901 A2
A-901
A4
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-102A
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
TH
IR
D F
LO
O
R R
C P
A
R E
A A
EV
13142646
WMC WMC
1704503
PLAN
NORTH
A
B
D
C
4' 8' 16'0'
PLAN
NORTH
1/8" = 1'-0" A1
THIRD FLOOR CEILING - AREA A
SHEET KEYNOTES
1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER
WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING
TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED
CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING
TILES AND GRIDS WITHIN AREA OF WORK.
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
3 DEMOLISH GYPSUM CEILING COMPLETE.
4 INSTALL NEW ACT CEILING.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
MEDIA PREP
A3084
LAB
A3082
COLD STORAGE
A3093
COLD STORAGE
A3095
LAB
A3041
LAB PREP
A3038
CONFERENCE
A3035
OPEN OFFICE
A3036
CONFERENCE
A3037
LAB
A3039
LAB
A3040
OFFICE
A3042B
OFFICE
A3083
OFFICE
A3085
ELEV
ELEV
OFFICE
A3034
ALCOVE
A3032
ELEV
STAIR
A3S2
OFFICE
A3006
OPEN OFFICE
A3007
LAB
A3005
LAB
A3033
OFFICE
A3031
OFFICE
A3008
OFFICE
A3009C
OFFICE
A3009A E
F
G
MATCHLINE SEE SHEET A-102A MATCHLINE SEE SHEET A-102A
MATCHLINE SEE SHEET A-102D MATCHLINE SEE SHEET A-102D
M A
T C
H
LI
N E
S E
E S
H E
E T
A -1
C
M A
T C
H
LI
N E
S E
E S
H E
E T
A -1
C
CORRIDOR
A3901
CORRIDOR
A3901
CORRIDOR
A3904
LAB
A3094
UTILITY CHASE
A3086
LAB
A3033A
OFFICE
A3009B
STORAGE
A3030B
STORAGE
A3030C
OFFICE
A3081
OFFICE
A3042A
STORAGE
A3030D
CORRIDOR
A3902
M A
T C
H
LI
N E
A R
E A
N O
T
IN
S C
O P
E M
A T
C H
LI
N
E A
R E
A N
O T
IN
S
C O
P E
A-901C4
1 2
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-102B
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
TH
IR
D F
LO
O
R R
C P
A
R E
A B
EV
13142647
WMC WMC
1704503
PLAN
NORTH
A
B
D
C
4' 8' 16'0'
PLAN
NORTH
1/8" = 1'-0" A1
THIRD FLOOR CEILING - AREA B
SHEET KEYNOTES
1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER
WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING
TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED
CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING
TILES AND GRIDS WITHIN AREA OF WORK.
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
1 7
C
A
42 3 5 6 8 9
OPEN OFFICE
A3020
OFFICE
A3026
OPEN OFFICE
A3027
OPEN OFFICE
A3028
OPEN OFFICE
A3031A
OFFICE
A3031
OFFICE
A3008
OFFICE
A3010
OFFICE
A3011
OFFICE
A3012
OPEN OFFICE
A3016
OFFICE
A3017
LAB
A3030
LAB
A3025
OPEN OFFICE
A3009
OFFICE
A3009D
OFFICE
A3009E
OFFICE
A3009F
LAB
A3013A
LAB
A3013
LAB
A3018
LAB
A3023
OFFICE
A3009C
OFFICE
A3009A
CONFERENCE
A3014
B
D
MATCHLINE SEE SHEET A-102B MATCHLINE SEE SHEET A-102B
CORRIDOR
A3901
CORRIDOR
A3902
OFFICE
A3020B
OFFICE
A3020A
OFFICE
A3020C
OFFICE
A3022
OFFICE
A3020D
OFFICE
A3009B
STORAGE
A3030B
STORAGE
A3030C
LAB
A3030A
LAB
A3013BLAB
A3013C
CORRIDOR
A3905
STORAGE
A3030D
LAB
A3025A
ELEC
A3091A ELEC
A3091
TEL
A3090
LAB
A3013D
1 2 A-901
C2
1. FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET A-001.
2. TEMPORARILY RELOCATE OR PROTECT IN PLACE FURNITURE AND
EQUIPMENT AS REQUIRED FOR DEMOLITION AND NEW WORK ACTIVITIES.
3. CEILING MOUNTED EQUIPMENT INCLUDING, LIGHTING, SPEAKERS, ETC.
MUST REMAIN SUSPENDED AND PROTECTED IN PLACE IN AREAS OF
WORK SHOWN ON THE REFLECTED CEILING PLAN.
4. PROTECT IN PLACE EXISTING TO REMAIN SPRINKLERS. CUT AWAY
ACOUSTICAL CEILING TILE AROUND SPRINKLERS. PROVIDE NEW TY3231
QUICK RESPONSE RECESSED PENDENT SPRINKLERS TO MATCH EXISTING
SPRINKLERS IN AREAS WHERE THE REMOVAL OF SPRINKLERS IS
NECESSARY TO FACILITATE MECHANICAL EQUIPMENT REPLACEMENT.
REMOVED PIPING MAY BE REUSED IF IN GOOD WORKING CONDITION.
REMOVED SPRINKLERS MUST NOT BE REUSED. COORDINATE WORK
BETWEEN DISCIPLINES.
5. FIRE ALARM DETECTION AND NOTIFICATION DEVICES TO REMAIN.
REINSTALL DEVICES WITHIN THE SAME LOCATION WHERE CEILING TILES
ARE REPLACED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
A-102D
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
TH
IR
D F
LO
O
R R
C P
A
R E
A D
EV
13142648
WMC WMC
1704503
PLAN
NORTH
A
B
D
C
4' 8' 16'0'
PLAN
NORTH
1/8" = 1'-0" A1
THIRD FLOOR CEILING - AREA D
SHEET KEYNOTES
1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER
WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING
TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED
CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING
TILES AND GRIDS WITHIN AREA OF WORK.
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
A-901
U S
U -7
P
E R
F O
R M
D E
S
IG
N F
O R
H V
A C
P H
O T
O G
R A
P H
S
EV
13142649
WMC WMC
1704503
NOT TO SCALE
C1
SECOND FLOOR TYPICAL CLASSROOM
NOT TO SCALE
C2 A3020
NOT TO SCALE
A4
A3053
NOT TO SCALE
C4
A3040
NOT TO SCALE
A2
A3047
SHEET KEYNOTES
1 REMOVE AND STORE EXISITING ACT CEILING TILES, GRIDS AND HANGER
WIRES AS NEEDED TO COMPLETE NEW WORK. REINSTALL EXISTING CEILING
TILES, GRIDS AND HANGER WIRES. REPAIR AND REPLACE ANY DAMAGED
CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 80% OF CEILING
TILES AND GRIDS WITHIN AREA OF WORK.
2 PROTECT CEILING MOUNTED EQUIPMENT TO REMAIN DURING
CONSTRUCTION. REFER TO GENERAL NOTES AND MEP DRAWINGS FOR
EXTENT OF WORK.
5 MOVE EXISTING ACT CEILING TILES AS NEEDED TO ACCESS AND COMPLETE
NEW WORK. REINSTALL EXISTING CEILING TILES. REPAIR AND REPLACE ANY
DAMAGED CEILING TILES AND GRIDS. ACCOUNT FOR REPLACEMENT OF 20%
OF CEILING TILES AND GRIDS WITHIN AREA OF WORK.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS IN THIS SET.
SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL
SHEET NOTES.
2. PATCH HOLES VACATED FROM REMOVAL OF PIPING, DUCTWORK.
3. REFER TO ARCHITECTURAL FOR WORK TO RESTORE CEILINGS DAMAGED BY
DEMOLITION OF MECHANICAL.
4. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR
REQUIRED TO PROVIDE COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS
INDICATED AND REQUIRED BY CODE.
5. PROVIDE ALL MECHANICAL EQUIPMENT AN APPURTENANCES IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS, AS INDICATED, AND AS
REQUIRED BY CODE. WHERE THE ABOVE REQUIREMENTS ARE IN CONFLICT,
PROVIDE THE MOST STRINGENT.
6. PROVIDE VIBRATION ISOLATORS FOR ALL MECHANICAL EQUIPMENT TO
PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE.
7. EXISTING DUCT AND PIPING SIZES INDICATED ARE APPROXIMATE. FIELD VERIFY
ALL DIMENSIONS.
8. LOCATE NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED CEILINGS
UNLESS OTHERWISE INDICATED.
9. 90 DEGREE MITERED DUCT ELBOWS IN THE SUPPLY AND RETURN DUCT SHALL
HAVE TURNING VANES.
10. AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED PIPE
LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE FOLLOWING PIPING, AT
10 FOOT ON CENTER ON THE PIPING MAINS AND 5 FOOT ON CENTER ON THE
BRANCH RUNOUTS FROM THE MAINS.
11. PIPE RUNOUTS MUST BE SIZED AS INDICATED ON EQUIPMENT SCHEDULES.
12. DUCT RUNOUT SIZE TO DIFFUSER, REGISTER, OR GRILLE MUST BE THE SAME
AS NECK SIZE.
13. MOUNT THERMOSTATS, HUMIDISTATS, AND EMERGENCY SHUTOFF SWITCHES
48 INCHES ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. REFER TO
ELECTRICAL DRAWINGS FOR LOCATION OF LIGHT SWITCHES AND COORDINATE.
14. SLOPE CONDENSATE PIPING 1/8 INCH PER FOOT DOWNWARD IN THE DIRECTION
OF FLOW. PROVIDE CLEANOUTS AT EACH CHANGE IN DIRECTION GREATER
THAN 45 DEGREES OR ONCE EVERY 45 FEET OF LINEAR PIPE LENGTH. UTILIZE
COMBINATION WYE AND 1/8 BENDS SHALL BE USED IN LIEU OF TEES.
15. MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND MAY NOT SHOW
EVERY OFFSET, FITTING, AND CONNECTION NECESSARY FOR A COMPLETE
INSTALLATION. PROVIDE ADDITIONAL OFFSETS, FITTINGS, AND CONNECTIONS
REQUIRED FOR COMPLETE AND OPERABLE SYSTEM.
16. VERIFY AND COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH
OTHER TRADES PRIOR TO BEGINNING WORK. WORK MUST PROVIDE ACCESS
FOR MAINTENANCE WITHOUT REQUIRING REMOVAL OR DISASSEMBLY OF
ADJACENT SYSTEMS.
GENERAL MECHANICAL NOTES
° DEGREES
Ø DIAMETER
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AP ACCESS PANEL
APD AIR PRESSURE DROP
AS AIR SEPARATOR
ATFP ANTITERRORISM FORCE PROTECTION
BD BALANCING DAMPER
BHP BRAKE HORSEPOWER
BOD BOTTOM OF DUCT
BR BASEBOARD RADIATOR
BTUH BRITISH THERMAL UNITS PER HOUR
C COMMON
Cv LOSS COEFFICIENT
CAV CONTSTANT AIR VOLUME
CFM CUBIC FEET PER MINUTE
CLG CEILING
CND CONDENSER
COP COEFFICIENT OF PERFORMANCE
CRAHU COMPUTER ROOM AIR HANDLING UNIT
CU CONDENSING UNIT
CHW CHILLED WATER
CW CONDENSER WATER
D CONDENSATE DRAIN
DB DRY BULB
DDC DIRECT DIGITAL CONTROL
DEG DEGREE
DP DIFFERNTIAL PRESSURE
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EFF EFFECTIVENESS
EQPT EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXF EXFILTRATION
F FAHRENHEIT
FCU FAN COIL UNIT
FD FIRE DAMPER
FT FEET
FT WG FEET WATER GAUGE
G NATURAL GAS
GPM GALLONS PER MINUTE
HGT HEIGHT
HP HEAT PUMP, HORSEPOWER
HR HOUR, HUMIDITY RATIO
HW HOT WATER
IAW IN ACCORDANCE WITH
IWG INCHES WATER GAUGE
kW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LV LOUVER
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MCWB MEAN COINCIDENT WET BLUB
MIN MINIMUM
N NORTH
NC NORMALLY CLOSED, NOISE CRITERIA
NO NUMBER, NORMALLY OPEN
OA OUTSIDE AIR
OAU OUTSIDE AIR UNIT
PH PHASE
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
RA RETURN AIR
RH RELATIVE HUMIDITY
SA SUPPLY AIR
SIM SIMILAR
SP STATIC PRESSURE
SQ SQUARE
TA TRANSFER AIR
TYP TYPICAL
UH UNIT HEATER
UOI UNLESS OTHERWISE INDICATED
V VOLTS
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
W WIDTH, WEST
WB WET BULB
WPD WATER PRESSURE DROP
MECHANICAL ABBREVIATIONS
T
HUMIDITY SENSORH
THERMOSTAT
ROUND DUCT DIMENSION
RECTANGULAR DUCT DIMENSIONS (INCHES)
FLEXIBLE ROUND DUCT (5'-0" MAX LENGTH)
12x10
12"Ø
SUPPLY DUCT DOWN/UP
DOWNWARD DIRECTION OF SLOPED PIPING
RETURN DUCT DOWN/UP
GLOBE VALVE
GATE VALVE
BUTTERFLY VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
DRAIN VALVE WITH HOSE CONNECTION
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
BACKFLOW PREVENTER
RELIEF VALVE
MANUAL AIR VENT
AUTOMATIC AIR VENT
WYE STRAINER
STRAINER WITH BLOWDOWN VALVE
CLEAN OUT
PIPE REDUCER
ECCENTRIC REDUCER
UNION
PRESSURE GAUGE WITH SHUTOFF COCK
THERMOMETER
PIPE CAP
FLANGE
FLEXIBLE PIPE CONNECTOR
C.O.
EXHAUST DUCT DOWN/UP
M
M
MV
AV
R/D RISE (R) DROP (D) IN DIRECTION OF FLOW
ACCESS DOOR (AD), ACCESS PANEL (AP)
FIRE DAMPER
AD
FIRE /SMOKE DAMPER
SMOKE DAMPER
BD
BACKDRAFT DAMPER
AIRFLOW MEASURING STATION
OPEN/CLOSED CONTROL DAMPER, PARALLEL
BLADE, MOTOR OPERATED
MODULATING CONTROL DAMPER, OPPOSED
BLADE, MOTOR OPERATED
MANUAL BALANCE DAMPER
AFMS
ATFP EMERGENCY SHUTDOWN SWITCHESS
MANUAL CALIBRATED BALANCING VALVE
MECHANICAL LEGEND
BALL VALVE
DIFFERENTIAL PRESSURE SENSOR
DP
STATIC PRESSURE SENSOR
SP
PIPING TO BE REMOVED
CHILLED WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
CONDENSATE DRAIN PIPING
HOT WATER SUPPLY PIPING
HOT WATER RETURN PIPING
CHWR
CHWS
D
HHWR
HHWS
MECHANICAL PIPING LEGEND
POINT OF CONNECTION
POINT OF DISCONNECTION
CONSTRUCTION INTERFACE
DEMO
WORK
EXISTING
TO REMAIN
WORK EXISTING
TO REMAIN
EXISTING TO REMAIN
DEMO WORK
WORK
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
DETAIL NUMBER
SCALE
SHEET
REFERENCED
FROM
SECTION TAG
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
KEYNOTE TAG
KEYNOTE NUMBER
? PHOTOGRAPH TAG
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
PLAN
NORTH
SCALE
SHEET
REFERENCED
FROM
AIR DISTRIBUTION DEVICE
IDENTIFICATION
EQUIPMENT
IDENTIFICATION
VAV - XX
EQUIPMENT
TYPE
EQUIPMENT
NUMBER
175 CFM
#Ø SA-# (?)
QTY
MARK
AIR FLOW
NECK SIZE
38.85 N
LONGITUDE:
ELEVATION:
LATITUDE:
SUMMER DESIGN WET BULB (1%):
SUMMER DESIGN DRY BULB (1%):
WINTER DESIGN DRY BULB (99%):
STANDARD OUTDOOR DESIGN CONDITIONS:
21°F
75°F 92°F
77.04 W
15 FT.
HVAC DESIGN CRITERIA
LOCATION: WASHINGTON, DC
STATION ID# ICAO_KDCA
SUMMER
DESIGN DRY
BULB:
WINTER
DESIGN DRY
BULB:
STANDARD INDOOR DESIGN CONDITIONS:
78°F 50% RH 68°F NC*
SUMMER
DESIGN
HUMIDITY:
TYPICAL SPACES: OFFICES,
CONFERENCE ROOMS, ETC.
ROOM TYPE:
LAB SPACES 75°F 50% RH 68°F NC*
*UC - UNCONTROLLED
*NC - HUMIDITY NOT DIRECTLY CONTROLLED
WINTER
DESIGN
HUMIDITY:
CLIMATE ZONE 4A
1% HR/MCWB WET BLUB
1% HR/MCWB DRY BLUB
77°F 83°F
CEILING SUPPLY AIR DEVICE
CEILING RETURN AIR DEVICE
CEILING EXHAUST AIR DEVICE
LINEAR SLOT SUPPLY
SURFACE MOUNTED SUPPLY GRILLE
SURFACE MOUNTED RETURN/EXHAUST GRILLE
MECHANICAL LEGEND (CONT.)
LINEAR SLOT RETURN
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
M-001
U S
U -7
P
E R
F O
R M
D E
S
IG
N O
F H
V A
C
LE
G
E N
D , A
B B
R E
V
IA
TI
O
N S
A N
D N
O
TE
S
FYA
13142650
KEL KEL
10/28/2021
1704503
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
SHEET KEYNOTES
8 97653 421
L
J
I
H x6
E A
22x10 EA 30x18 EA x1
E
A
12x8 EA x1
E
A
A2051
10x12 SA
22x16 SA x1
S
A
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA 10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
A2052 A2053 A2054
A2048
A2050
A2047
A2046
A2040
A2041
A2045
A2037
SA3
A2057
A2061
A2065
A2066
A2064
A2063
A2062
A2060
A2058
A2056
A2055A
A2055
14x12 SA
22x16 SA
16x12 SA
10x12 SA
10x12 SA
10x10 SA
20x10 SA
10x10 SA
8x
S A
20x10 SA
20x8 SA
10x10 SA10x10 SA
8x8 SA
10x10 SA
8x8 SA
10x10 SA
8x8 SA
20x16 SA
6x6 SA x1
S
A 8x8 SA
8x8 SA
8x8 SA
8x8 SA
8x8 SA
8x8 SA
8x8 SA
10x8 SA
14x12 SA
10x10 SA x2
S
A x3
S A
8x8 SA
6x8 SA
14x8 SA x2
S
A
10x10 SA
10x10 SA x1
S
A
10x8 SA
8x10 SA
8x8 SA
6x8 SA
6x8 SA
UP TO
EF-2
SUPPLY AIR
SHAFT FROM
AHU-2 & -3
SUPPLY AIR
SHAFT FROM
AHU-9 & -10
16x14 SA
12x12 SA
8x12 SA
CAV-206 (E)
VAV-204 (E)
CAV-203 (E)
CAV-202 (E)
VAV-207A (E)
VAV-207B (E)
CAV-211 (E)
CAV-2C01 (E)
CAV-2C06 (E)
VAV-213A (E)
VAV-213B (E)
VAV-217A (E)
VAV-217B (E)
CAV-2C02 (E)
VAV-218 (E)
VAV-219 (E)
VAV-220 (E)
VAV-221 (E)
VAV-222 (E)
VAV-223 (E)
VAV-224 (E)
VAV-225 (E)
VAV-226 (E)
VAV-212 (E)
10x6 EA
17X17
UP TO
LVL 3
ER HOOD (E)
750 CFM
CAV-208A (E)
8x8 SA
8x8 SA
24x20 SA x2
S
A x2
S A
48x36 SA
24x20 SA x2
S
A x2
S A
CAV-214A (E)
CAV-214B (E)
10x8 SA
12x8 EA
CAV-215A (E)
x1
E
A x1
E A x1
E
A
12x8 EA x2
E
A
CAV-215B (E)
CAV-216A (E)
CAV-216B (E)
12x8 EA
A2049 x1
E
A
34x18 EA 38x18 EA x1
E
A x1
E A
12x10 EA
12x10 EA x1
E
A x1
S
A
8x12 SA
8x10 SA
A2071
A2902
10x8 SA
CAV-208B (E)
TYP.
CAV-209A (E)
CAV-209B (E) TYP.
CAV-210B (E)
CAV-210A (E)
TYP.
TYP.
TYP.
TYP.
A2903
CAV-205 (D)
VAV-201 (D)
MATCHLINE SEE SHEET MD101B
19 12x10 EA
1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
MD101A
U S
U -7
P
E R
F O
R M
D E
S
IG
N O
F H
V A
C
S E
C O
N D
F
LO
O R
A R
E A
A
D E
M O
LI
TI
O N
D
U C
TW
O
R K
P
LA
N
FYA
13142651
KEL KEL
10/28/2021
1704503
1 REMOVE CAV BOX, DUCTWORK, ASSOCIATED SUPPORTS, CONTROLS WIRING,
INSULATION AND APPURTENANCES.
2 REMOVE VAV BOX, DUCTWORK, ASSOCIATED SUPPORTS, CONTROLS WIRING,
INSULATION AND APPURTENANCES.
5 DEMOLISH DUCT INCLUDING INSULATION, HANGERS, AND ASSOCIATED AIR
TERMINALS.
19 DEMOLISH DUCTWORK TO POINTS INDICATED.
23 EXISTING TERMINAL UNIT AND ASSOCIATED DUCTWORK, CONTROLS, AND
APPURTENANCES TO REMAIN. PROTECT DURING CONSTRUCTION.
4' 8' 16'0'
PLAN
NORTH
PLAN
NORTH
A
B
D
C
RM. NUMBER RM. NAME RM. SERVED BY
A2037 JANITOR AHU-2 & -3
A2040 LAB AHU-2 & -3
A2041 CLASSROOM AHU-2 & -3
A2045 CLASSROOM AHU-2 & -3
A2046 OPEN OFFICE AHU-2 & -3
A2047 OPEN OFFICE AHU-2 & -3
A2048 OPEN OFFICE AHU-2 & -3
A2049 CLASSROOM AHU-2 & -3
A2050 LAB AHU-2 & -3
A2051 OPEN OFFICE AHU-2 & -3
A2052 CONFERENCE ROOM AHU-2 & -3
A2053 CONFERENCE ROOM AHU-9 & -10
A2054 STORAGE AHU-9 & -10
A2055 OFFICE AHU-9 & -10
A2055A OFFICE AHU-9 & -10
A2056 OFFICE AHU-9 & -10
A2057 CLASSROOM AHU-9 & -10
A2058 OFFICE AHU-9 & -10
A2060 OFFICE AHU-9 & -10
A2061 CLASSROOM AHU-9 & -10
A2062 OFFICE AHU-9 & -10
A2063 OFFICE AHU-9 & -10
A2064 OPEN OFFICE AHU-9 & -10
A2065 CLASSROOM AHU-9 & -10
A2066 OPEN OFFICE AHU-9 & -10
A2071 UTILITY CHASE AHU-2, -3, -9, & -10
A2901 CORRIDOR AHU-9, -10, -12, & -13
A2902 CORRIDOR AHU-2, -3, -5, & -6
A2903 CORRIDOR AHU-2, -3, -9, & -10
1/8" = 1'-0" A1
SECOND FLOOR AREA A - DEMOLITION - DUCTWORK PLAN
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
E
H
G
F
16x8 EA
18x12 EA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
MATCHLINE SEE SHEET MD101A
SA2 44
A2031
A2032
A2033
A2034
A2035
A2007A
A2002
A2004
A2006
A2074
A2068
A2067
A2039
A2070
A2069
10x8 SA x1
S
A
8x10 SA
6x8 SA
6x8 SA
28x8 SA
30x12 RA x1
S
A
8x6 SA
14x12 SA x3
S
A
8x
S A
16x14 SA10x12 SA
14x12 SA
8x12 SA 6x
S
A
6x
S A
6x
S A
8x10 SA
8x10 SA
6x8 SA x2
S
A x2
S A x1
S
A
10x8 SA
8x10 SA
10x10 SA
20x14 SA x1
S
A
12x10 SA
12x10 SA 12x12 SA x1
S
A
8x8 SA6x8 SA
8x
S A
10x10 SA x1
S
A x2
S A x1
S
A x1
S A
18x10 SA 6x10 SA
8x
E A
12x10 SA
18x12 EA
6x
S A
16x10 SA
10x10 SA
8x8 EA
UP TO
EF-4
UP TO
EF-6
UP TO
EF-12
UP TO
EF-13
SUPPLY AIR
SHAFT FROM
AHU-5 & -6
10x12 SA
VAV-237 (E)
CAV-234 (E)
VAV-238 (E)
CAV-235 (E)
CAV-235A (E)
CAV-235B (E)
CAV-235C (E)
VAV-241 (E)
VAV-240 (E)
VAV-239 (E)
CAV-2C05A (E)
CAV-2C05B (E)
CAV-2C05D (E)
6x8 SA
VAV-227A (E)
VAV-227B (E)
VAV-236 (E)
CAV-231 (E)
CAV-2C04 (E)
VAV-229 (E)
CAV-228 (E)
CAV-2C05E (E)
CAV-2C03A (E)
A2904
A2071A
12ø EA
UP TO
EF-29
x8
E A
10ø UP
TO LVL
CAV-233B (E)
CAV-230B (E)
CAV-230A (E)
12x10 EATYP.
CAV-233A (E)
12x8 EA TYP.
CAV-232A (E)
CAV-232B (E)
12x8 EA TYP.
A2902
A2012
8x6 EA
8x
S A
MATCHLINE SEE SHEET MD101D
A2007B A2007C
A2007
A2071 x1
E
A x1
E
A
1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
MD101B
U S
U -7
P
E R
F O
R M
D E
S
IG
N O
F H
V A
C
S E
C O
N D
F
LO
O R
A R
E A
B
D E
M O
LI
TI
O N
D
U C
TW
O
R K
P
LA
N
FYA
13142652
KEL KEL
10/28/2021
1704503
19 DEMOLISH DUCTWORK TO POINTS INDICATED.
4' 8' 16'0'
PLAN
NORTH
PLAN
NORTH
A
B
D
C
RM. NUMBER RM. NAME RM. SERVED BY
A2002 OFFICE AHU-12 & -13
A2004 OFFICE AHU-12 & -13
A2006 OFFICE AHU-12 & -13
A2007 LAB AHU-12 & -13
A2007A OFFICE AHU-12 & -13
A2007B OFFICE AHU-12 & -13
A2007C OFFICE AHU-12 & -13
A2012 UTILITY CHASE AHU-5, -6, -12, -13
A2031 CLASSROOM AHU-5 & -6
A2032 ALCOVE AHU-5 & -6
A2033 LAB AHU-5 & -6
A2034 OPEN OFFICE AHU-2 & -3
A2035 LAB AHU-5 & -6
A2039 CLASSROOM AHU-2 & -3
A2067 OPEN OFFICE AHU-9 & -10
A2068 OFFICE AHU-12 & -13
A2069 CLASSROOM AHU-9 & -10
A2070 STORAGE AHU-12 & -13
A2071 UTILITY CHASE AHU-2, -3, -9, & -10
A2074 CONFERENCE ROOM AHU-12 & -13
A2901 CORRIDOR AHU-9, -10, -12, & -13
A2902 CORRIDOR AHU-2, -3, -5, & -6
A2904 CORRIDOR AHU-5 & -6
1/8" = 1'-0" A1
SECOND FLOOR AREA B - DEMOLITION - DUCTWORK PLAN
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
E
D
C
B
A x1
E
A
36x16 EA 10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
10x12 SA
MATCHLINE SEE SHEET MD101B
A2019
A2020A
A2020
A2020B
A2024
A2027
A2030
A2029
A2025
A2021 A2017
A2013
A2009
A2010
A2008
A2011
A2015
6x
S A
16x16 SA 16x14 SA 10x14 SA x3
S
A
8x8 SA x1
S
A x2
S A
8x8 SA
8x8 SA x2
S
A
8x
S A x2
S
A x3
S A
8x8 SA 8x8 SA
12x6 SA x8
E A
10x8 SA
12x6 SA
30x14 EA
8x8 SA
10x10 SA
8x
S A
8x10 SA
8x8 SA
8x8 SA x1
E
A
16x4 EA
16x6 EA x4
E A
38X18
EA UP
TO
EF-8
22X12 EA
FROM
GROUND
LEVEL
SUPPLY AIR
SHAFT FROM
AHU-12 & -13
FCU-001 (E)
VAV-259 (E)
VAV-260 (E)
VAV-261A (E)
VAV-261B (E)
VAV-262 (E)
CAV-255 (E)
8x8 SA
VAV-2C08 (E)
VAV-249 (E)
VAV-242A (E)
VAV-242B (E)
VAV-244 (E)
VAV-245 (E)
VAV-246 (E)
VAV-247 (E)
VAV-248 (E)
CAV-254 (E)
VAV-250 (E)
x1
E
A
CAV-2C03B (E)
A2905
CAV-258B (E)
CAV-258A (E)
CAV-257B (E)
CAV-257A (E)
CAV-256B (E)
CAV-256A (E)
6x
S
A
CAV-253B (E)
10x12 SACAV-253A (E)
CAV-253C (E)
A2021E
CAV-252B (E)
CAV-252A (E)
x1
E
A
CAV-251B (E)
CAV-251A (E)
x8
S A
12x8 EA TYP.
12x8 EA TYP.
12x8 EA TYP.
A2012
12x8 EA TYP.
8x
S A
TYP.
19 19
1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
MD101D
U S
U -7
P
E R
F O
R M
D E
S
IG
N O
F H
V A
C
S E
C O
N D
F
LO
O R
A R
E A
D
D E
M O
LI
TI
O N
D
U C
TW
O
R K
P
LA
N
FYA
13142653
KEL KEL
10/28/2021
1704503
19 DEMOLISH DUCTWORK TO POINTS INDICATED.
23 EXISTING TERMINAL UNIT AND ASSOCIATED DUCTWORK, CONTROLS, AND
APPURTENANCES TO REMAIN. PROTECT DURING CONSTRUCTION.
4' 8' 16'0'
PLAN
NORTH
PLAN
NORTH
A
B
D
C
RM. NUMBER RM. NAME RM. SERVED BY
A2008 CONFERENCE ROOM AHU-12 & -13
A2009 CLASSROOM AHU-12 & -13
A2010 OPEN OFFICE AHU-12 & -13
A2011 CONFERENCE ROOM AHU-12 & -13
A2012 UTILITY CHASE AHU-5, -6, -12, -13
A2013 CLASSROOM AHU-12 & -13
A2015 CONFERENCE ROOM AHU-12 & -13
A2017 CLASSROOM AHU-12 & -13
A2019 OFFICE AHU-5 & -6
A2020 OFFICE AHU-5 & -6
A2020A OFFICE AHU-5 & -6
A2020B OFFICE AHU-5 & -6
A2021 CLASSROOM AHU-5 & -6
A2021E STORAGE AHU-5 & -6
A2024 OFFICE AHU-5 & -6
A2025 CLASSROOM AHU-5 & -6
A2027 OFFICE AHU-5 & -6
A2028 OFFICE AHU-5 & -6
A2029 CLASSROOM AHU-5 & -6
A2030 OPEN OFFICE AHU-5 & -6
A2901 CORRIDOR AHU-9, -10, -12, & -13
A2902 CORRIDOR AHU-2, -3, -5, & -6
A2905 CORRIDOR AHU-5 & -6
1/8" = 1'-0" A1
SECOND FLOOR AREA D - DEMOLITION - DUCTWORK PLAN
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
F
IN
A
L D
E S
IG
N
S U
B M
IT
T
A L
/2
1/
L
J
I
H
A3045
A3046
A3047
A3050
A3053
A3043
A3049
A3079
A3076
A3072
A3062
A3066
A3068
A3069 A3063A3064A3058
A3056
A3059
A3S3 A3051
A3070
A3071
A3073
A3074
A3075
A3077
A3078
A3080 x1
S
A 8x
10x10
14x12 SA
6x6 SA 6x6 SA
8x8 SA
8x
S A
9x10 SA
6x8 SA
6x10 SA
8x8 SA
8x10 SA x1
S
A
8x10 SA
8x6 SA 8x6 SA
12x10 SA
8x10 SA
A3048
8x8 SA x1
S
A
8x8 SA x1
S
A x2
S A
8x8 SA
8x8 SA
8x8 SA
8x8 SA
8x10 SA
8x8 SA
10x12 SA8x10 SA
18x12 SA
10x12 SA x3
S
A x1
S A x3
S
A
12x14 SA8x12 SA
12x14 SA
12x12 SA
10x12 SA 14x14 SA
10x12 SA
14x14 SA
48x36 SA x3
S
A x3
S A x1
S
A x1
S
A x1
S
A
14x8 SA
48x32 SA x2
S
A x1
S A
10x14 SA
14x14 12x14 x1
14x14
10x12
20x10 SA
14x14 12x14 x1
14x14
16x14 SA x1
S
A x1
S
A x1
S
A10x12 SA
22x12 SA
14x14 SA 10x12 SA
10x12 SA
6x8 SA
10x10 SA
12x16 SA
6x10
8x
S A
8x
S A x2
S
A
8x6
8x8
8x
S A
8x
S A
8x10 SA
8x
S A
14x12 SA
8x8 SA
8x
S A
8x
S A x1
S
A x1
S A x1
E
A x1
E
A x1
E A x3
E
A x1
E
A x1
E A x1
E
A
SUPPLY AIR
SHAFT FROM
AHU-2 & -3
SUPPLY AIR
SHAFT FROM
AHU-9 & -10
18x14 EA
40X40
EA UP
TO EF-1
DOWN TO
LEVEL 2
40X18 EA
UP TO
EF-2
38x48 EA
UP TO EF-9
76X24 EA
DOWN TO
LEVEL 2
FCU-002
FCU-003
FCU-004
VAV-316B (E)
CAV-316A (E)
CAV-314 (E)
CAV-317B (E)
CAV-317A (E)
CAV-313A (E)
A3060
VAV-305 (E)
VAV-302 (E)
VAV-304A (E)
VAV-304B (E)
VAV-304C (E)
CAV-320 (E)
CAV-3C03A (E)
CAV-3C03B (E)
CAV-3C01 (E)
VAV-303 (E)
CAV-324B (E)
CAV-321 (E)
CAV-324A (E)
CAV-323B (E)
CAV-323A (E)
CAV-322B (E)
CAV-322A (E)
CAV-3C02 (E)
VAV-310 (E)
VAV-309 (E)
VAV-307 (E)
VAV-308 (E)
VAV-306 (E)
CAV-3C04B (E)
CAV-3C04A (E)
VAV-311 (E)
VAV-312 (E)
VAV-325 (E)
VAV-326 (E)
VAV-327 (E)
VAV-328 (E)
VAV-329 (E)
VAV-330 (E)
VAV-331 (E)
VAV-332 (E)
17X17
UP TO
EF-24
12ø UP
TO
EF-25
8x12 SA
A3057 x1
S
A
A3061A A3061B
8x6 SA
A3067 x1
S
A
A3903
A3086
CAV-318A (D)
CAV-318B (D)
CAV-315 (D)1
VAV-313B (D)
VAV-301 (D)
1 0x 12
CAV-319B (D) 1
CAV-319A (D)
MATCHLINE SEE SHEET MD102B
A3042D A3042C
A3042
1. REFER TO DRAWING M-001 FOR MECHANICAL LEGEND, ABBREVIATIONS AND
NOTES.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 31 JANUARY 2017
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
W
A S
H
IN
G T
O N
N A
V Y
Y A
R D
W A
S H
IN
G
T O
N D
.C
B. JAEGER, P.E.
U N
IF
O
R M
E D
S E
R V
IC
E
U N
IV
E
R S
IT
Y
B E
T H
E S
D A
M
A R
Y L A
N D
AS NOTED
KEY PLAN
SHEET NOTES
MD102A
U S
U -7
P
E R
F O
R M
D E
S
IG
N O
F H
V A
C
TH
I…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .