Attachment E AS124 Dwgs_Part2of2.pdf
PDF 5 MB Posted
- Attached to
- IDIQ SB MACC, General Construction, MCI East AOR
- Solicitation number
- N4008521R1215
About this file
This is a request for proposal (RFP) for an indefinite-delivery/indefinite-quantity (IDIQ) multiple award construction contract (MACC) for general construction services within the Marine Corps Installations East area of responsibility (AOR). The RFP seeks to award multiple IDIQ contracts to provide construction services for minor and major projects up to $5 million per task order. The period of performance is one base year with four option years. Offerors must be small businesses and responses are due by July 6, 2021, with awards anticipated by September 2021. Pricing will be evaluated on a firm-fixed-price basis for individual task orders issued on a performance work statement. The RFP establishes a 20% small business set-aside. The Naval Facilities Engineering Command is the contracting agency. Incumbents may recompete for follow-on awards.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t t
GUH07
GUH06
GUH05
GUH01
GUH02
GUH03
GUH04
GUH08
GUH09
GUH10
PV02
L1
L2
L3
L4
L5
PV03
PV01
DHP01
DAH01
PV04
R R
R R
C C
T
T
T
T T
T
T
T
T
T
6"
ØC
E109
WOOD SHOP
E111
TOOL STOR.
E110
STORAGE
E107
STORAGE
E106
STORAGE
E104
TOILET
E105
STORAGE
E101
STOR.
E102
STORAGEE103
STORAGE
E116
WAREHOUSE
E115
STOR.
E114
STORAGE
E112
OFFICE
E113
STOR.
E108
ENTRY
E117
COMPRESSOR
(X)LPC (X)LPC
(X)LPS (X)LPS
(X)LPC
(X )L
P S
(X )L
P S
(X)LPS
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X)LPS
(X)LPC
(X)LPS
(X )L
P S
(X)LPS
(X)LPC
(X)LPS
(X)LPC
(X )L
P C
(X )L
P C
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P S
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X )L
P C
(X)LPC(X)LPS
(X)LPS
(X)LPC
T H BURTON, PE
INTERIOR/EXTERIOR
REPAIRS BLDG. AS124
CAMP LEJEUNE, NORTH CAROLINA
05-17-0075 N40085-17-D-0859
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com c Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
NC# P-0506
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-1
JULY 27, 2018
CONSTRUCTION KEYED NOTES
1 MOUNT UNIT HEATER AS HIGH AS STRUCTURE ALLOWS FOLLOWING MANUFACTURERS
RECOMMENDATIONS. ALIGN AS SHOWN. ROUTE UNIT INTAKE / EXHAUST THROUGH
ADJACENT WALL. SEE DETAIL: 1/M-3.
MOUNT UNIT HEATER BELOW BUILDING TRUSSES. ALIGN AS SHOWN. ROUTE UNIT INTAKE /
EXHAUST THROUGH ADJACENT WALL ABOVE LOWER ROOF. SEE DETAIL: 1/M-3.
MOUNT UNIT HEATER BELOW BUILDING TRUSSES. ALIGN AS SHOWN. ROUTE UNIT INTAKE /
EXHAUST THROUGH ADJACENT WALL. SEE DETAIL: 1/M-3.
MOUNT EXHAUST FAN AS HIGH AS AS STRUCTURE ALLOWS FOLLOWING MANUFACTURES
RECOMMENDATIONS. SEE DETAIL: 2/M-3.
MOUNT EXHAUST FAN OPENING SHOWN ON ARCHITECTURAL PLANS AND ELEVATIONS.
SEE DETAIL: 2/M-3.
MOUNT AS HIGH AS POSSIBLE. MODIFY STRUCTURE AS REQUIRED TO MAKE WEATHER
TIGHT.
GRAVITY DRAIN CONDENSATE PIPING EXPOSED ALONG WALL AND DISCHARGE TO PLASH
BLOCK
ROUTE REFRIGERANT PIPING CONCEALED FROM INDOOR UNIT TO OUTDOOR UNIT (IN
WALLS AND ABOVE CEILINGS.
1/8" = 1'-0" 0 8' 16'4'2 FLOOR PLAN
PLAN
NORTH
M-2HVAC PLANS
RWC
RWC
DMH
60024430
MECHANICAL
1/8" = 1'-0" 0 8' 16'4'1 DEMOLITION FLOOR PLAN
PLAN
NORTH
DEMOLITION KEYED NOTES
1 DEMOLISH EXISTING STEAM PIT CONCRETE PIT, PIPING AND EQUIPMENT. FILL AND MATCH
SURROUNDING CONDITIONS.
DEMOLISH EXISTING CONDENSATE RECEIVER AND EXISTING STEAM AND CONDENSATE
PIPING.
DEMOLISH EXISTING EXHAUST FAN AND LOUVER.
DEMOLISH EXISTING STEAM AND CONDENSATE PIPING.
DEMOLISH EXISTING STEAM UNIT HEATER, PIPING AND SUPPORTS.
DEMOLISH EXISTING ELECTRIC UNIT HEATER AND SUPPORTS.
DEMOLISH EXISTING RADIATOR HEATER, PIPING AND SUPPORTS.
EXISTING DUST COLLECTION DUCTWORK. SYSTEM TO BE REMOVED DURING
CONSTRUCTION. REFER TO ARCHITECTURAL PLANS.
3 3
3/4" CONDENSATE
GRAVITY DRAIN
EG1
L6
AutoCAD SHX Text R116
AutoCAD SHX Text
WAREHOUSE
AutoCAD SHX Text R109
AutoCAD SHX Text
WOOD SHOP
AutoCAD SHX Text R111
AutoCAD SHX Text
TOOL STOR.
AutoCAD SHX Text R110
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text R108
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text R106
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
TOILET
AutoCAD SHX Text R107
AutoCAD SHX Text
DATA/COMM
AutoCAD SHX Text R101
AutoCAD SHX Text
STOR.
AutoCAD SHX Text R102
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text R104
AutoCAD SHX Text R117
AutoCAD SHX Text
COMPRESSOR
AutoCAD SHX Text
TALLEY & SMITH ARCHITECTURE INC.
AutoCAD SHX Text
P.O. BOX 518 SHELBY, NC 28151-0518
AutoCAD SHX Text
409 EAST MARION ST. SHELBY, NC 28150
AutoCAD SHX Text
DES.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SATISFACTORY TO:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
CODE IDENT. NO.
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text 80091
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text 23551
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text H
AutoCAD SHX Text M.
AutoCAD SHX Text D
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text I
T H BURTON, PE
INTERIOR/EXTERIOR
REPAIRS BLDG. AS124
CAMP LEJEUNE, NORTH CAROLINA
05-17-0075 N40085-17-D-0859
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com c Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
NC# P-0506
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-1
JULY 27, 2018
M-3DETAILS
RWC
RWC
DMH
60024431
MECHANICAL
UNIT
HEATER
LISTED TERMINAL
LISTED TERMINAL
6" M
IN
12"
SLOPE 1/4" PER FOOT DOWNWARD
TOWARD FROM UNIT
SUPPORT BRACKET
TEE WITH DRIP LEG AND CLEANOUT CAP
AT LOW POINT OF SYSTEM4"MIN
HORIZONTAL
DISCHARGE
EXTERIOR WALL
NOTE: UNIT HEATER VENT DETAIL SHOWS GENERAL
GUIDANCE FOR HEATERS SCHEDULED, REFER TO
MANUFACTURERS INSTALLATION MANUAL FOR COMPLETE
REQUIREMENTS.
EXHAUST
COMBUSTION AIR
LISTED THIMBLE
LENGTH AS REQ'D
SINGLE PIPE RUN
MULTIPLE PIPE RUNS
SA
AIRFLOW
AIRFLOW
INSULATED RS, RL
REFRIGERANT LINES.
SIZE PER MFR
CONNECTION CABLE
TO THERMOSTAT
3/4"Ø INSULATED CONDENSATE
GRAVITY DRAIN LINE TO GRADE,
SPLASH BLOCK
SUPPORT FROM EXISTING
STRUCTURE UNLESS
OTHERWISE INDICATED
INSULATION SADDLE
STEEL PIPE STRAP
BOLT & CLAMPING NUT (TYP)
1 5/8"x1 5/8"x12 GA.
STEEL CHANNEL
SUPPORT FROM
ROOF JOISTS.
INSULATION
SADDLE
CLEVIS HANGER
(SIZE AS REQ'D)
3/8"Ø THREADED ROD
GALVANIZED STEEL
HOUSING ASSEMBLY
1/2" MESH SCREEN
FASTENED TO WALL WITH 3/8"
EXPANSION BOLTS (TYP)
SEA COAST CONSTRUCTION
BACKDRAFT DAMPER
WALL, VERIFY CONSTRUCTION
WEATHERPROOF
LOUVER
4" THICK CONCRETE PAD (MIN. 4"
EXTENSION ALL SIDES)
OUTDOOR UNIT (DHP) SECURE
TO CONCRETE PAD
POWER & HIGH VOLTAGE
CONTROL TO INDOOR UNIT
THERMISTOR
CABLE
WALL SLEEVE WITH CAPS
FURNISHED BY FCU MFGR.
INDOOR UNIT (DAH)
WALL MOUNTING BRACKET
FURNISHED BY FCU MFGR.
NOT TO SCALE1 GAS FIRED UNIT HEATER VENT DETAIL
NOT TO SCALE2 EXHAUST FAN/LOUVER DETAIL
NOT TO SCALE3 DUCTLESS HEAT PUMP UNIT DETAIL
NOT TO SCALE4 PIPE SUPPORT DETAIL
GALVANIZED STEEL
HOUSING ASSEMBLY
1/2" MESH SCREEN
FASTENED TO WALL WITH 3/8"
EXPANSION BOLTS (TYP)
AUTO BACKDRAFT DAMPER
WALL, VERIFY CONSTRUCTION
WEATHERPROOF
LOUVER
NOT TO SCALE5 TYPICAL LOUVER DETAIL
NOTE: WALL EITHER BLOCK
OR METAL WALL
MAINTAIN MANUFACTURERS
CLEARANCE RECOMMENDATIONS
System No. C-AJ-5090
SECTION A-A
CA
J 5
A
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
January 14, 2015
A
2 1 5B
5A
5B
Hilti Firestop Systems
C
CL
ASS I F IED
R
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
Page: 2 of 2Hilti Firestop Systems
CA
J 5
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
January 14, 2015 Page: 1 of 2
1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 18 in. (457 mm).
See Concrete Blocks (CAZT) Category in the Fire Resistance Directory for names of manufacturers.
2. Metallic Sleeve — (Optional) — Nom 18 in. (457 mm) diam (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall.
3. Through Penetrants — One metallic pipe or tubing to be centered within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe.
B. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper tubing.
C. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.
4. Tube Insulation — Plastics+ — Min 1/2 in. (13 mm) to max 3/4 in. (19 mm) thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. Nom 1 in. (25 mm) thick AB/PVC flexible foam insulation may be used for max 2 hr F and FH Ratings when max 3 in. (76 mm) diam pipe or tubing is used. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When max annular space exceeds 1-1/2 in. (38 mm) the F and FH Ratings are 2 hr.
See Plastics+ (QMFZ2) Category in the Recognized Component Directory for names of manufacturers. Any Recognized Component tube insulation material meeting the above specifications and having a UL 94 Flammability Classification of 94-5VA may be used.
5. Firestop System — The firestop system shall consist of the following:
A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.
B. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. When max annular space exceeds 1-1/2 in. (38 mm) the min thickness of fill material is 1/2 in. (13 mm).
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Ratings — 2 and 3 Hr (See Item 4) F Ratings — 2 and 3 Hr (See Item 4)
T Rating — 0 Hr FT Rating — 0 Hr
L Rating At Ambient — 4 CFM/sq ft FH Ratings — 2 and 3 Hr (See Item 4)
L Rating At 400 F — Less Than 1 CFM/sq ft FTH Rating — 0 Hr
L Rating At Ambient — 4 CFM/sq ft
L Rating At 400 F — Less Than 1 CFM/sq ft
AutoCAD SHX Text
TALLEY & SMITH ARCHITECTURE INC.
AutoCAD SHX Text
P.O. BOX 518 SHELBY, NC 28151-0518
AutoCAD SHX Text
409 EAST MARION ST. SHELBY, NC 28150
AutoCAD SHX Text
DES.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SATISFACTORY TO:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
CODE IDENT. NO.
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text 80091
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text 23551
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text H
AutoCAD SHX Text M.
AutoCAD SHX Text D
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text L
I
REPAIRS BLDG. AS124
CAMP LEJEUNE, NORTH CAROLINA
05-17-0075 N40085-17-D-0859
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com c Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
NC# P-0506
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-1
JULY 27, 2018
E-1LEGEND, SUMMARIES, DETAIL
JLG
JLG
WAC
60024432
ELECTRICAL
DESCRIPTIONSYMBOL
4FT OR 8FT LIGHT FIXTURE, RECESSED OR SURFACE MOUNTED
LETTER INDICATES FIXTURE TYPE (SEE FIXTURE SCHEDULE)
ELECTRICAL LEGEND
4FT OR 8FT CHANNEL LIGHT FIXTURE, SUSPENDED OR SURFACE MOUNTED
LETTER INDICATES FIXTURE TYPE (SEE FIXTURE SCHEDULE)
WALL MOUNTED LIGHT FIXTURE
LETTER INDICATES FIXTURE TYPE (SEE FIXTURE SCHEDULE)
EXIT SIGN, SINGLE FACE, CEILING, ARROW INDICATES DIRECTION.
LETTER INDICATES FIXTURE TYPE (SEE FIXTURE SCHEDULE)
EMERGENCY LIGHTING UNIT, 2-HEAD WITH BATTERY BACK-UP, WALL MOUNTED, "NOT
SWITCHED"
INDICATES FIXTURE TYPE (SEE FIXTURE SCHEDULE)
PHOTOCELL, REMOTE MOUNTED, 120V, 10 SECOND TIME DELAY, UL WET LOCATION,
RATED FOR 1500 W @ 120 VAC (FOR USE WITH LAMP SOURCE(S) SHOWN
PE
3-WAY SWITCH, SINGLE POLE 120/277 VAC, 20A, MOUNTED AT 46" AFF UNLESS OTHERWISE
NOTED
SWITCH, SINGLE POLE, 120/277VAC, 20A, MOUNTED AT 46" AFF UNLESS OTHERWISE
NOTED (SEE ELECTRICAL MOUNTING HEIGHT DETAIL). LOWER CASE LETTER
INDICATES FIXTURE SWITCHING (WHEN INDICATED)
DESCRIPTIONSYMBOL
ELECTRICAL LEGEND
MANUAL MOTOR STARTER, ELECTRICAL CONTRACTOR SHALL COORDINATE POLES
AND SIZE WITH EQUIPMENT
## = AMPERAGE RATING WHEN INDICATED ON DRAWING
RECESSED SINGLE/DOUBLE GANG BOX WITH BLANK COVER PLATE, MOUNTED 16" AFF,
UNLESS OTHERWISE NOTED
RECEPTACLE, DUPLEX, 120VAC, 20A, MOUNTED 16" AFF, UNLESS OTHERWISE NOTED. (SEE
ELECTRICAL MOUNTING HEIGHT DETAIL)
WP - LISTED WEATHER-RESISTANT TYPE DEVICE WITH WEATHERPROOF, EXTRA DUTY,
WHILE IN USE COVER
GFI - GROUND FAULT CIRCUIT INTERRUPTER TYPE, 120VAC, 20A, MOUNTED 24" AFF
RECEPTACLE, DUPLEX, 120VAC, 20A, MOUNTED 6" ABOVE COUNTER TOP OR BACK SPLASH.
+##" - INDICATES MOUNTING HEIGHT OF DEVICE IN INCHES AFF (IF GIVEN) (SEE
ELECTRICAL MOUNTING HEIGHT DETAIL)
RECEPTACLE, QUADPLEX, 120VAC, 20A MOUNTED 16"AFF UNLESS OTHERWISE NOTED (SEE
ELECTRICAL MOUNTING HEIGHT DETAIL)
WP - LISTED WEATHER-RESISTANT TYPE DEVICE WITH WEATHERPROOF, EXTRA DUTY,
WHILE IN USE COVER
GFI - GROUND FAULT CIRCUIT INTERRUPTER TYPE, 120VAC, 20A, MOUNTED 24" AFF
RECEPTACLE-TWIST LOCK, 20A, WALL MOUNTED 16" AFF, SIZE AND CONFIGURATION AS
INDICATED ON DRAWING
CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR, 360° COVERAGE
WALL MOUNTED OCCUPANCY SENSOR, SINGLE BUTTON ON/OFF CONTROL, 180°
COVERAGE, MOUNTED AT 46" AFF UNLESS OTHERWISE NOTED.
OS
DISCONNECT SWITCH, FUSED, HEAVY (GENERAL) DUTY, SIZE AS INDICATED ON DRAWINGS
##A = DISCONNECT SIZE / # = NUMBER OF POLES / # = NEMA RATING,
/##AF = FUSE SIZE
30A/3/4X
W/ 30AF
COMBINATION STARTER WITH CIRCUIT BREAKER DISCONNECT, FULL VOLTAGE, SIZE AS
INDICATED ON DRAWINGS
"Equip"
#AMP
HMCP
(#HP)
NEMA #
PANELBOARD, SURFACE OR RECESSED MOUNTED AS SHOWN. SIZE, RATINGS, AND
MOUNTING AS INDICATED ON PANEL SCHEDULE. CONTRACTOR IS RESPONSIBLE FOR
REQUIRED CLEARANCE IN FRONT OF ELECTRICAL PANEL. SEE NEC TABLE 110.26
WORKING SPACES FOR ADDITIONAL CLEARANCE CONDITIONS.
208/120V
CONDUIT, HOME RUN TO PANEL BOARD
uuu 3 HOUR RATED FIRE WALL
HATCHING INDICATES ITEMS TO BE DEMOLISHED. REMOVE DEVICE, EQUIPMENT,
FIXTURE INDICATED, CIRCUIT, AND CONDUIT BACK TO SOURCE UNLESS OTHERWISE
NOTED.
3 BUTTON - ON/OFF/STOP PUSHBUTTON CONTROLLER
POWER & SWITCH LEG
UNSWITCHED LEG
SO
S3
SM ##
S
A, AMP
AFF
AFG
AHU
AIC
ATS
AWG
BOF
BRKR
C, CND
CAB
CAT
CL
CB
CCTV
CKT
CLG
CP
CR
CS
CV
CT
CU
EF
EMER
EMT
ENCL
EQUIP
EWC
EWH
EPRF
FA
FAAP
FACP
FBO
FLA
FLUOR
FLR
FWE
GEN
G, GND
GFI
HH
HID
HOA
HP
HPF
HPS
HTR
HV
Hz
IMC
INCAND
JB
K
KCMIL
KVA
KW
KWH
LP
LTG
MCB
MCC
MCP
MDP
MFR
MH
MLO
MTD
MTG
MTS
MV
N, NEUT
NA
NC
NEC
NIC
NL
NO
NTS
P
PA
PB
PF
PH,ɸ
PLC
PNL
PP
PT
PWR
RECPT, RCP
REQ'D
RGS
RM
RTU
SCR
SH
SPEC
SS
SST
SW
SWBD
SWGR
TEL
TPS
TVSS
TYP
UGND
UH
UON
UTIL
V
VFD
W
WH
WP
XFMR
AMPERE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BOTTOM OF FIXTURE
BREAKER
CONDUIT
CABINET
CATALOG
CHLORINE
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
CIRCUIT
CEILING
CONTROL PANEL
CONTROL RELAY, CORROSION RESISTANT
CONTROL SWITCH
CONTROL VALVE
CURRENT TRANSFORMER
COPPER
EXHAUST FAN
EMERGENCY
ELECTRICAL METALLIC TUBING
ENCLOSURE
EQUIPMENT
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXPLOSION PROOF
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FURNISHED BY OTHERS
FULL LOAD AMPS
FLUORESCENT
FLOOR
FURNISHED WITH EQUIPMENT
GENERATOR
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
HANDHOLE
HIGH INTENSITY DISCHARGE
HAND-OFF-AUTO
HORSE POWER
HIGH POWER FACTOR
HIGH PRESSURE SODIUM
HEATER
HIGH VOLTAGE
HERTZ
INTERMEDIATE METALLIC CONDUIT
INCANDESCENT
JUNCTION BOX
THOUSAND
THOUSAND CIRCULAR MILLS
KILOVOLT AMPERE
KILOWATTS
KILOWATT-HOURS
LIGHTING PANEL, LIGHT POLE
LIGHTING
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MAIN DISTRIBUTION PANEL
MANUFACTURER
MANHOLE
MAIN LUGS ONLY
MOUNTED
MOUNTING
MANUAL TRANSFER SWITCH
MEDIUM VOLTAGE
NEUTRAL
NOT APPLICABLE
NORMALLY CLOSED
NATIONAL ELECTRIC CODE
NOT IN CONTRACT
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
POLE
PUBLIC ADDRESS
PULL BOX, PUSH-BUTTON
POWER FACTOR
PHASE
PROGRAMMABLE LOGIC CONTROLLER
PANEL
POWER PANEL, POWER POLE
POTENTIAL TRANSFORMER
POWER
RECEPTACLE
REQUIRED
RIGID GALVANIZED STEEL CONDUIT
ROOM
REMOTE TELEMETRY UNIT
DC MOTOR DRIVE
SHEET
SPECIFICATION
SELECTOR SWITCH
STAINLESS STEEL
SWITCH
SWITCHBOARD
SWITCH GEAR
TELEPHONE
TWISTED PAIR SHIELDED
TRANSIENT VOLTAGE SURGE SUPPRESSER
TYPICAL
UNDERGROUND
UNIT HEATER
UNLESS OTHERWISE NOTED
UTILITY
VOLTS
VARIABLE FREQUENCY DRIVE
WIRE, WATT
WATT-HOUR
WEATHERPROOF
TRANSFORMER
ABBREVIATIONS:
FINISHED CEILING
FLOOR
DOOR
EXIT
ABOVE COUNTER
RECEPTACLE/DATA
3"
TV
NOTE:
DETAIL SHOWN FOR REFERENCE ONLY, NOT ALL DEVICES ARE INDICATED ON PLANS.
BACK SPLASH
SS
SM
STRIKE
SIDE
HINGE
SIDE
COUNTER TOP
S3 SDS
LIGHT SWITCH
DIMMER
CABLE, VOICE/DATA,
DUPLEX & QUADRAPLEX
RECEPTACLES
GANG
SWITCHING
CABLE &
TV
OUTLET
MECHANICAL
CASETTE
CABLE & TV OUTLET RECEPTACLE FOR
TV OUTLET
CLOCK HANGER
RECEPTACLE
WALL MOUNTED EXIT SIGN
ABOVE DOOR (MAX. MT. HT.
OF 80" ABOVE TOP OF DOOR)
NOT TO SCALE1 ELECTRICAL DEVICES - MOUNTING HEIGHT DETAIL
6"6"
E Q
.E Q
EQ.EQ.EQ.
LOAD SUMMARY
VOLTAGE PHASE
208 3
LARGEST MOTOR APPROX. AMPS 24 AMPS
LARGEST MOTOR APPROX. AMPS x .25 6 AMPS
HVAC
GUHs(10) 3,996 VA
EXHAUST FANS(4) 2,188 VA
DHP01/DAHO1 1,997 VA
SUB-TOTAL HVAC DEMAND 8,181 VA
SUB-TOTAL HVAC DEMAND 23 AMPS
EQUIPMENT
EWH01 2,500 VA
DUST COLLECTOR 8,719 VA
COMPRESSOR 6,017 VA
10" TABLE SAW 2,400 VA
TABLE SAW 7,206 VA
RADIAL ARM SAW 7,926 VA
JOINTER 5,404 VA
DRILL PRESS 1,800 VA
BAND SAW 1,152 VA
MITER SAW 1,152 VA
WET SAW 1,800 VA
SANDER 1,080 VA
BENCH GRINDER 600 VA
SUB-TOTAL EQUIPMENT DEMAND 45,255 VA
SUB-TOTAL EQUIPMENT DEMAND 126 AMPS
ADD FOR LARGEST MOTOR 6 AMPS
TOTAL EQUIPMENT DEMAND 132 AMPS
LIGHTING
LIGHTS (INTERIOR, BASED ON NEC 220.12) 5,912 VA
LIGHTS (EXTERIOR) 364 VA
SIGN 1,200 VA
TOTAL LIGHTING LOAD 7,476 VA
LIGHTING LOAD x 1.25 9,345 VA
TOTAL DEMAND FOR LIGHTING 26 AMPS
RECEPTACLES
RECEPTACLES 11,340 VA
FIRST 10000VA 10,000 VA
REMAINDER @ 50% 670 VA
TOTAL DEMAND FOR RECEPTACLE/POWER PANELS 10,670 VA
TOTAL DEMAND FOR RECEPTACLE/POWER PANELS 30 AMPS
TOTAL DEMAND BUILDING AMPS 210 AMPS
TOTAL DEMAND BUILDING AMPS 75,613 VA
TOTAL BUILDING CONNECTED LOAD 72,252 VA
GROUND BAR - 'TMGB' INDICATES TELECOMMUNICATIONS GROUND BAR - 'EGB' INDICATES
ELECTRICAL GROUND BAR
3/4"x4'x8' FIRE RATED PLYWOOD
COMBINATION DATA/TELEPHONE OUTLET, PROVIDE 1 1/4" CONDUIT FROM ROOM R107 TO
SURFACE MOUNTED 5 SQUARE BOX. PROVIDE (QTY) 4 - CAT 6A CABLES, COMPLETE FROM
EACH DROP TO ROOM R107 DATA RACK.
WIRELESS ACCESS POINT, PROVIDE 1" CONDUIT FROM ROOM R107 TO SURFACE
MOUNTED 5 SQUARE BOX. PROVIDE (QTY)1 - CAT 6A CABLE, COMPLETE FROM DATA RACK
IN ROOM R107 TO DEVICE LOCATION. GOVERNMENT MUST PROVIDE SURGE PROTECTOR
AND WAP DEVICE, THE ELECTRICAL CONTRACTOR MUST INSTALL.
swing
WALL MOUNTED DATA RACK
WAP
AutoCAD SHX Text
TALLEY & SMITH ARCHITECTURE INC.
AutoCAD SHX Text
P.O. BOX 518 SHELBY, NC 28151-0518
AutoCAD SHX Text
409 EAST MARION ST. SHELBY, NC 28150
AutoCAD SHX Text
DES.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SATISFACTORY TO:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
CODE IDENT. NO.
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text 80091
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text 023311
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text W.
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text
SEAL
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text H
AutoCAD SHX Text E file:///L:/Elect/LightFixtureCutShts/Lithonia/LithUN4'Strip.pdf file:///L:/Elect/LightFixtureCutShts/Lithonia/LithUN4'Strip.pdf
REPAIRS BLDG. AS124
CAMP LEJEUNE, NORTH CAROLINA
05-17-0075 N40085-17-D-0859
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com c Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
NC# P-0506
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-1
JULY 27, 2018
E-2GENERAL & DEMOLITION NOTES
JLG
JLG
WAC
60024433
ELECTRICAL
GENERAL NOTES
1. ALL ELECTRICAL WORK SHALL BE IN FULL COMPLIANCE WITH NFPA 70 THE NORTH CAROLINA STATE BUILDING CODE, ALL LOCAL CODES AND ORDINANCES AND
IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION.
2. ALL EQUIPMENT PROVIDED BY THE CONTRACTOR SHALL BE LISTED AND LABELED BY A NATIONALLY-RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, FOR THE CONDITIONS OF INSTALLATION. ALL MATERIAL, EQUIPMENT AND DEVICES SHALL BE NEW CURRENT PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH PRODUCTS. EQUIPMENT SHALL BE SUITABLE FOR ITS APPLICATION (E.G. WHEN
INSTALLED OUTDOORS, IT SHALL BE WEATHERPROOF, ETC.)
3. THE CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR WORK REQUIREMENTS, THE AMOUNT OF SPACE AVAILABLE FOR ELECTRICAL
EQUIPMENT, AND LAYOUT HIS WORK IN A COMPATIBLE AND COMPLEMENTARY MANNER.
4. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THOROUGHLY FAMILIARIZING HIMSELF WITH ANY CONTRACTUAL REQUIREMENTS AS MAY BE SET FORTH
IN THE OTHER DIVISIONS OF THE PROJECT SPECIFICATIONS.
5. UNLESS SPECIFICALLY NOTED OTHERWISE, SYSTEMS PROVIDED OR INSTALLED BY THE CONTRACTOR SHALL BE COMPLETE AND FULLY-FUNCTIONING AFTER INSTALLATION. INCIDENTAL COMPONENTS MAY NOT BE SHOWN, AND ALL WORK WHICH MAY BE REASONABLY IMPLIED AS BEING INCIDENTAL TO THIS WORK, BUT REQUIRED FOR THE PROPER OPERATION OF THE EQUIPMENT OR SYSTEM, SHALL BE PROVIDED BY THE CONTRACTOR AND INCLUDED IN THE BID.
ADDITIONAL CIRCUITS SHALL BE INSTALLED WHEREVER NEEDED TO CONFORM TO THE SPECIFIC REQUIREMENTS OF EQUIPMENT.
6. TEMPORARY POWER CONNECTIONS AS REQUIRED SHALL BE PROVIDED BY THE CONTRACTOR AND INCLUDED IN THE BID. ALL TEMPORARY EQUIPMENT WIRING SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. THE CONTRACTOR SHALL PROVIDE DETAILS, METHODS, MATERIALS, ETC. FOR REVIEW PRIOR TO MAKING TEMPORARY CONNECTIONS. FURNISH AND INSTALL ALL EQUIPMENT AND MATERIALS INCLUDING CONTROL EQUIPMENT, MOTOR STARTERS, BRANCH AND FEEDER CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, ETC. FOR TEMPORARY POWER. COORDINATE WITH THE ELECTRICAL UTILITY
COMPANY AS REQUIRED.
7. THE WORK SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING AT THE COMPLETION OF WORK AND ANY MINOR CORRECTIONS, CHANGES OR
ADJUSTMENTS NECESSARY FOR THE PROPER FUNCTIONING OF THE SYSTEM AND EQUIPMENT.
8. ALL EQUIPMENT SHOWN DOTTED OR DASHED IS BY OTHERS OR IS EXISTING, AS NOTED.
9. ALL ELECTRICAL EQUIPMENT SHALL, AT ALL TIMES DURING CONSTRUCTION, BE ADEQUATELY PROTECTED AGAINST MECHANICAL INJURY, OR DAMAGE BY WATER AND/OR THE ELEMENTS. ELECTRICAL EQUIPMENT SHALL NOT BE STORED OUT OF DOORS, BUT SHALL BE STORED IN DRY PERMANENT SHELTERS. IF AN APPARATUS HAS BEEN DAMAGED, OR HAS BEEN SUBJECT TO POSSIBLE INJURY BY WATER OR THE ELEMENTS, SUCH DAMAGE SHALL BE REPLACED AT NO
ADDITIONAL COST.
10. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS.
11. CIRCUIT LAYOUTS ARE NOT INTENDED TO SHOW THE NUMBER OF FITTINGS, OR OTHER INSTALLATION DETAILS. UNLESS NOTED OTHERWISE, THE EXACT ROUTING OF FEEDER AND BRANCH CIRCUIT RACEWAYS AND CABLES IS THE RESPONSIBILITY OF THE CONTRACTOR. RISER AND GENERAL CIRCUIT ARRANGEMENTS ARE SHOWN SCHEMATICALLY/DIAGRAMMATICALLY ONLY. THE CONTRACTOR SHALL ROUTE CONDUITS AS REQUIRED BY THE CONDITIONS OF
THE INSTALLATION.
12. UNLESS DIMENSIONED, DEVICE LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE. ADJUST EXACT LOCATIONS AS REQUIRED TO SERVE THE INTENDED PURPOSE AND TO AVOID CONFLICTS AND INTERFERENCES WITH OTHER TRADES. EXACT DEVICE LOCATIONS SHALL BE AS INDICATED ON THE ARCHITECTURAL DRAWINGS OR AS DIMENSIONED. IF NOT SHOWN ON THE ARCHITECTURAL DRAWINGS OR DIMENSIONED ON THE ELECTRICAL DRAWINGS, VERIFY EXACT LOCATION WITH THE CONTRACTING OFFICER PRIOR TO ROUGH-IN.
13. CONDUIT TERMINATING IN PRESSED STEEL BOXES SHALL HAVE DOUBLE LOCKNUTS AND INSULATED BUSHINGS. CONDUITS TERMINATING IN GASKETED
ENCLOSURES SHALL BE TERMINATED WITH GROUNDING TYPE CONDUIT HUBS.
14. BRANCH CIRCUIT HOMERUNS SHOWN ON DRAWINGS INDICATE PHASE CONDUCTORS, NEUTRAL, EQUIPMENT GROUND CONDUCTORS AS REQUIRED.
ADDITIONAL CONDUCTORS REQUIRED FOR CONTROL SHALL BE INCLUDED EVEN IF NOT EXPLICITLY SHOWN.
15. SEAL ALL CONDUIT OPENINGS THROUGH EXTERIOR BUILDING WALLS WATERTIGHT.
16. IN WET LOCATIONS AND EXTERIOR, ALL WIRING DEVICES SHALL BE WEATHER-RESISTANT LISTED WITH WEATHERPROOF WHILE IN USE COVER. LIGHTING FIXTURES SHALL BE APPROPRIATELY RATED AND LISTED FOR THE ENVIRONMENT ITO BE INSTALLED IN.
17. RACEWAYS PENETRATING FLOORS, CEILINGS OR WALLS SHALL BE PROPERLY SEALED SMOKETIGHT.
18. ALL RACEWAYS SHALL BE CONCEALED WHERE POSSIBLE IF APPLICABLE, MATCH EXISTING RACEWAY INSTALLATION METHODS AND ROUTINGS AT OR NEAR
EXISTING FACILITIES.
19. INSTALL EXPOSED RACEWAYS PARALLEL TO OR AT RIGHT ANGLES TO NEARBY SURFACES OR STRUCTURAL MEMBERS, AND FOLLOW THE SURFACE CONTOURS AS MUCH AS POSSIBLE. NO DIAGONAL RUNS WILL BE ALLOWED. ALL CONDUITS SHALL BE RUN STRAIGHT AND TRUE. RUN PARALLEL OR BANKED RACEWAYS TOGETHER ON COMMON SUPPORTS WHERE PRACTICAL. MAKE BENDS IN PARALLEL OR BANKED RUNS FROM SAME CENTERLINE TO MAKE BENDS
PARALLEL.
20. PATCHING OF WATERPROOFED SURFACES SHALL RENDER THE AREA OF THE PATCHING COMPLETELY WATERPROOF.
21. ALL MOTORS , DRY TYPE TRANSFORMERS AND OTHER VIBRATING EQUIPMENT SHALL BE CONNECTED TO THE CONDUIT SYSTEM BY MEANS OF A SHORT SECTION (18 INCH MINIMUM) OF FLEXIBLE CONDUIT UNLESS OTHERWISE INDICATED. AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED INSIDE THE FLEXIBLE CONDUIT AND TERMINATE AT THE LOAD END WITH AN APPROVED GROUNDING CLAMP OR LUG.
22. SURFACE MOUNTED PANELBOARDS, JUNCTION, OUTLET AND PULL BOXES, RACEWAYS, ETC., INSTALLED ON EXTERIOR SURFACES OR INSIDE ON EXTERIOR WALLS SHALL BE SUPPORTED BY SPACERS TO PROVIDE A 1/4" MINIMUM CLEARANCE BETWEEN THE WALL AND EQUIPMENT.
23. CEILING MOUNTED DEVICES INSTALLED IN ACOUSTICAL TILE CEILING AREAS SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE WITH RODS OF SUFFICIENT SIZE TO PREVENT VERTICAL MOVEMENT OF THE OUTLET BOX. BRIDGES ALONE ARE NOT ADEQUATE UNLESS SPECIFICALLY APPROVED. CEILING MOUNTED EXIT LIGHT FIXTURES SHALL BE INSTALLED LEVEL. DO NOT SUPPORT DEVICES FROM ACOUSTICAL CEILING TILE.
24. PROVIDE ADHESIVE BACKED RECEPTACLE DEVICE PLATE LABELS IDENTIFYING THE CIRCUIT FEEDING THE DEVICE. LABELS SHALL INDICATE PANEL AND CIRCUIT NUMBER. ALSO PROVIDE IDENTIFICATION FOR MULTI-WIRE BRANCH CIRCUIT PHASE CONDUCTORS IN PANELBOARD.
25. FINAL TYPED PANELBOARD DIRECTORIES INSTALLED IN THE PANELBOARD DOOR POCKET SHALL INCLUDE FINAL ACTUAL ROOM NAMES AND NUMBERS IN ADDITION TO THE GENERAL DESCRIPTION SHOWN ON THE PANEL SCHEDULES ON THE DRAWINGS.
26. CONDUCTOR SIZING IS BASED ON 75 DEGREE C. COPPER NEC RATINGS, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL VERIFY, PRIOR TO INSTALLATION OF CONDUCTORS OR CONDUIT FEEDING ANY EQUIPMENT, THE ELECTRICAL EQUIPMENT IS RATED FOR USE WITH 75 DEGREE C. WIRING. IF ANY EQUIPMENT IS RATED FOR USE WITH LESS THAN 75 DEGREE C. CONDUCTORS, THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IMMEDIATELY
FOR EVALUATION/CORRECTION.
27. DO NOT PULL CONDUCTORS UNTIL THE CONDUIT SYSTEM IS COMPLETE IN EVERY DETAIL. IN THE CASE OF CONCEALED WORK, "COMPLETE" MEANS UNTIL ALL
ROUGH PLASTERING OR MASONRY HAS BEEN COMPLETED.
28. WHERE SIZE IS NOT SHOWN ON THE DRAWINGS, BRANCH CIRCUITS SHALL CONSIST OF #12 OR #10 AWG MINIMUM PHASE, NEUTRAL AND EQUIPMENT GROUND
CONDUCTORS IN 3/4” MINIMUM RACEWAY.
29. USE #10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS WITH A TOTAL INSTALLED LENGTH GREATER THAN 75 FEET AND/OR BRANCH CIRCUIT HOMERUNS LONGER THAN 50 FEET, I.E.; #12 AWG INCREASED TO #10 AWG FOR RECEPTACLE BRANCH CIRCUITS OVER 75 FEET TOTAL LENGTH
(INCLUDING THE AWG HOMERUN SEGMENT) AND HOMERUNS OVER 50 FEET.
30. COMMON NEUTRAL CONDUCTORS OF MULTIWIRE RECEPTACLE BRANCH CIRCUIT HOMERUNS SHALL BE #10 AWG MINIMUM.
31. KEEP CONDUCTOR SPLICES TO A MINIMUM. INSTALL SPLICES AND TAPES THAT POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN CONDUCTORS BEING SPLICED. USE SPLICE AND TAP CONNECTORS COMPATIBLE WITH CONDUCTOR MATERIAL. INSTALL CONDUCTORS AT EACH OUTLET WITH AT LEAST 6 INCHES OF SLACK. CONNECT OUTLETS AND COMPONENTS TO WIRING AND TO GROUND AS INDICATED AND INSTRUCTED BY
THE MANUFACTURER.
32. DO NOT SPLICE BRANCH CIRCUIT HOMERUNS WITHOUT THE PERMISSION OF THE CONTRACTING OFFICER. HOMERUNS SHALL BE CONTINUOUS FROM THE
LAST OUTLET BOX TO THE SERVING PANELBOARD.
33. DO NOT COMBINE BRANCH CIRCUIT HOMERUNS UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
34. DO NOT CHANGE CIRCUITING SHOWN WITHOUT PERMISSION OF THE CONTRACTING OFFICER.
35. TROUGH TAPS SHALL BE AT SWITCH AMPACITY, UNLESS NOTED OTHERWISE.
36. INSTALL WIRING DEVICES AT HEIGHTS AS SHOWN ON THE DRAWINGS. ALSO COORDINATE MOUNTING HEIGHTS WITH THE ARCHITECTURAL DRAWINGS AND CASEWORK DETAILS. IF CONFLICTING, ARCHITECTURAL DRAWINGS AND DETAILS SHALL GOVERN.
37. PROVIDE GROUND FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL IN ACCORDANCE WITH THE NEC INCLUDING ALL ELECTRIC WATER COOLERS, EXTERIOR RECEPTACLES AND RECEPTACLES IN AREAS SUBJECT TO POSSIBLE WET CONDITIONS. ALL RECEPTACLES INSTALLED WITHIN 6 FEET OF A SINK SHALL BE GFI PROTECTED. ALL RECEPTACLES IN NON-RESIDENTIAL KITCHENS SHALL BE GFI PROTECTED.
38. IN AREAS IN WHICH DUAL LEVEL SWITCHING IS INDICATED (TYPICALLY BY 2 OR MORE ADJACENT, GANGED SWITCHES), PROVIDE THE APPROPRIATE NUMBER
OF CONDUCTORS TO FACILITATE THIS FUNCTION (AS TYPICALLY SHOWN).
39. CONNECT BATTERY PACK TYPE EMERGENCY AND EXIT LIGHTING FIXTURES TO UN-SWITCHED LIGHTING CIRCUIT SERVING THE SPACE LIGHTED BY THE EMERGENCY AND EXIT FIXTURES. THESE CONNECTIONS ARE INTENTIONALLY NOT SHOWN TO MAINTAIN DRAWING FOR CLARITY.
40. COORDINATE LIGHTING FIXTURE LOCATIONS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. IF CONFLICTS ARE NOTED, REQUEST CLARIFICATION
FROM THE CONTRACTING OFFICER BEFORE PROCEEDING.
41. ADJACENT SWITCHES SHALL BE GANGED. INSTALL BARRIERS BETWEEN UNLIKE VOLTAGE SECTIONS.
42. SEPARATE NEUTRALS ARE REQUIRED FOR ALL DIMMED LIGHTING CIRCUITS.
43. WHERE THE DRAWINGS INDICATE A LIGHTING FIXTURE IS TO BE PROVIDED WITH SPECIAL FEATURES/SWITCHING (DIMMING, EMERGENCY BATTERY BALLAST, MULTI-LEVEL, ETC), THE CONTRACTOR SHALL PROVIDE THESE FIXTURES WITH THE APPROPRIATE BALLASTING TO ACCOMMODATE THE SPECIAL FEATURE.
THE CONTRACTOR SHALL PROVIDE THE FIXTURES AS INDICATED IN THE LIGHTING FIXTURE SCHEDULE WITH MODIFICATIONS AS REQUIRED BY DRAWING
NOTES.
44. COORDINATE LOCATIONS OF PLUMBING, MECHANICAL, DATA AND TELEPHONE AND AUDIO/VISUAL EQUIPMENT. GOVERNMENT-PROVIDED TELECOMMUNICATIONS AND DATA CABLES WILL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. LEAVE PULL WIRES OR ROPES OF ADEQUATE TENSILE
STRENGTH IN ALL EMPTY CONDUITS.
45. PROVIDE TELEPHONE, FIBER AND DATA SERVICE ENTRANCE CONDUIT IN SIZES AND LOCATIONS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY THE GOVERNMENT AND THE SERVICE UTILITIES. UTILITY SERVICE ENTRANCE CABLES WILL BE PROVIDED AND INSTALLED BY THE GOVERNMENT'S SERVICE UTILITIES. LEAVE PULL WIRES OR ROPES OF ADEQUATE TENSILE STRENGTH IN ALL EMPTY CONDUITS.
46. INSTALLATION INFORMATION PACKED WITH LIGHTING FIXTURES, DEVICES AND EQUIPMENT SHALL BE RETAINED FOR INCLUSION IN THE OPERATIONS AND
MAINTENANCE MANUALS.
47. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING NECESSARY TO INSTALL ALL EQUIPMENT AS REQUIRED AND SHALL REESTABLISH ALL FINISHES TO THEIR ORIGINAL CONDITION WHERE CUTTING AND PATCHING OCCUR. ALL CUTTING AND PATCHING SHALL BE DONE IN A THOROUGHLY WORKMANSHIP MANNER. SAW CUT CONCRETE AND MASONRY PRIOR TO BREAKING OUT SECTIONS. ALL PATCHING MATERIALS AND WORKMANSHIP SHALL BE PERFORMED BY TRADESMEN EXPERIENCED IN THAT WORK. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE RESPECTIVE SUPPLIERS AND VENDORS AND THE GOVERNMENT BEFORE ROUGH-IN. ADJUST LIGHTING FIXTURES, RECEPTACLES AND ELECTRICAL EQUIPMENT TO ACCOMMODATE THIS EQUIPMENT.
ADVISE THE GOVERNMENT OF CONFLICTS BEFORE ROUGH-IN.
48. BEFORE COMMENCING WORK OR ORDERING MATERIALS, THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND VERIFY THE NAMEPLATE RATINGS OF ALL EQUIPMENT (MOTORS, HEATERS, COMPRESSORS, ETC.) AND ADJUST THE RATINGS OF THE ELECTRICAL EQUIPMENT (SWITCHES, FUSES, CIRCUIT
BREAKERS, FEEDERS, ETC.) AS APPROPRIATE TO SERVE THIS EQUIPMENT.
49. ENERGIZE EQUIPMENT ONLY AFTER OBTAINING PERMISSION FROM THE CONTRACTOR PROVIDING THE EQUIPMENT.
50. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO ALL UTILIZATION EQUIPMENT SHOWN ON THE DRAWINGS.
VERIFY THE TYPE OF FINAL CONNECTION AND PROVIDE APPROPRIATE WIRING METHOD. THE CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND PLUMBING EQUIPMENT, PRIOR TO ORDERING OR INSTALLATION OF ANY EQUIPMENT, TO VERIFY MECHANICAL AND PLUMBING EQUIPMENT REQUIREMENTS ARE PROVIDED IN THE ELECTRICAL DESIGN. THE CONTRACTOR WILL NOT BE COMPENSATED FOR COSTS ASSOCIATED WITH CHANGING THE ELECTRICAL SYSTEMS TO MATCH UTILIZATION EQUIPMENT, EVEN IF THE ELECTRICAL WORK IS INSTALLED PER THE ELECTRICAL DRAWINGS.
51. THE CONTRACTOR SHALL FURNISH ALL STARTERS AND CONTROLS FOR THEIR EQUIPMENT. THE CONTRACTOR SHALL PROVIDE ALL SAFETY SWITCHES, SHALL MOUNT STARTERS AND PROVIDE WIRING AND CONNECTIONS TO LINE SIDE OF STARTERS. THE CONTRACTOR SHALL PROVIDE LOAD SIDE WIRING AND CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT. FOR RESISTANCE TYPE LOADS WHERE STARTERS OR CONTACTORS ARE NOT REQUIRED, THE CONTRACTOR SHALL PROVIDE ALL POWER WIRING AND CONNECTIONS COMPLETE TO EQUIPMENT. THE MECHANICAL AND PLUMBING CONTRACTORS SHALL
PROVIDE ALL CONTROL WIRING AND CONNECTIONS AND DEVICES FOR THEIR EQUIPMENT.
52. TELECOMMUNICATIONS AND DATA CABLES WILL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. LEAVE PULL WIRES OR ROPES OF ADEQUATE TENSILE
STRENGTH IN ALL EMPTY CONDUITS.
54. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING NECESSARY TO INSTALL ALL EQUIPMENT AS REQUIRED AND SHALL REESTABLISH ALL FINISHES TO THEIR ORIGINAL CONDITION WHERE CUTTING AND PATCHING OCCUR. ALL CUTTING AND PATCHING SHALL BE DONE IN A THOROUGHLY WORKMANSHIP MANNER. SAW CUT CONCRETE AND MASONRY PRIOR TO BREAKING OUT SECTIONS. ALL PATCHING MATERIALS AND WORKMANSHIP SHALL BE PERFORMED BY TRADESMEN EXPERIENCED IN THAT WORK. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE CONTRACTING OFFICER.
55. CORE DRILL HOLES IN EXISTING CONCRETE WALLS AS REQUIRED.
56. INSTALL WORK AT SUCH TIME AS TO REQUIRE THE MINIMUM AMOUNT TO CUTTING AND PATCHING.
57. CUT OPENINGS ONLY LARGE ENOUGH TO ALLOW EASY INSTALLATION OF THE CONDUIT.
58. ABANDONED POWER WIRING, RACEWAYS AND CONDUCTORS, SHALL BE REMOVED BACK TO THEIR SOURCE. THE ACCESSIBLE PORTIONS OF ABANDONED
CABLES (VOICE, DATA, VIDEO, ALARM, ETC.) SHALL BE REMOVED.
59. THE EXISTING ELECTRICAL SYSTEMS DEPICTED ON THESE DRAWINGS HAVE BEEN COMPILED BY THE ENGINEER FROM THE GOVERNMENT'S RECORD DRAWINGS AND LIMITED FIELD VERIFICATION OF THE EXISTING CONDITIONS FOR THE PURPOSE OF INDICATING THE WORK REQUIRED AND ARE BELIEVED TO BE CORRECT. NOTWITHSTANDING, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, POINTS OF ACCESS AND FIELD CONDITIONS AFFECTING HIS WORK.
60. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING ELECTRICAL SYSTEMS AND THE EXISTING BUILDING. THE SUBMISSION OF THE PROPOSAL BY THE CONTRACTOR SHALL BE CONSIDERED EVIDENCE THAT HE OR HIS REPRESENTATIVE HAS VISITED THE SITE AND BUILDINGS AND NOTED THE LOCATION AND CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED AND THAT HE TAKES FULL RESPONSIBILITY OF ALL FACTORS GOVERNING HIS WORK. NO EXTRAS WILL BE CONSIDERED BECAUSE OF ADDITIONAL WORK NECESSITATED BY EXISTING JOB CONDITIONS THAT ARE NOT INDICATED ON THE
DRAWINGS.
61. ALL UNUSED OUTLET BOXES SHALL BE REMOVED OR, WITH SPECIFIC APPROVAL OF THE CONTRACTING OFFICER, SHALL BE BLANKED WITH STAINLESS STEEL PLATES. ALL OPENINGS IN EXISTING WALLS AND CEILINGS MADE BY THIS CONTRACTOR SHALL BE REPAIRED TO AN EQUAL FINISH AS ADJACENT SURFACES.
62. PROVIDE ALL ELECTRICAL RELOCATION WORK ASSOCIATED WITH THE RELOCATING OF EQUIPMENT FOR THE EXISTING FACILITIES, INCLUDING DISCONNECTING ALL EXISTING WIRING AND CONDUITS AND PROVIDING NEW WIRING AND CONDUITS TO THE RELOCATED EQUIPMENT.
63. SEE "KEYED DEMOLITION NOTES" FOR ADDITIONAL REQUIREMENTS.
64. SAFETY
A. COMPLY WITH OSHA AND NEC ARC FLASH PROTECTION REQUIREMENTS.
B. FOR EQUIPMENT BEING REMOVED AND REPLACED, THE CONTRACTOR SHALL DE-ENERGIZE THE EQUIPMENT AND MAKE IT SAFE PRIOR TO REMOVAL AND COMPLY WITH OSHA REQUIREMENTS FOR LOCKING-OUT AND TAGGING EQUIPMENT TO PREVENT INADVERTENT RE-ENERGIZING.
C. WHERE EQUIPMENT IS BEING REMOVED, BUT NOT REPLACED, REMOVE THE CONDUCTORS FEEDING THE EQUIPMENT BACK TO THE POINT WHERE THEY RECEIVE POWER. REMOVE ACCESSIBLE CONDUITS. ABANDON IN PLACE INACCESSIBLE CONDUITS. AFTER REMOVAL OF EQUIPMENT, REPAIR ANY OPENING LEFT TO MATCH SURROUNDING WALLS, CEILINGS, OR FLOORS TO THE CONTRACTING OFFICER SATISFACTION.
D. COORDINATE WITH THE OTHER TRADES, PRIOR TO BID, AND INCLUDE IN THE BASE BID THE ELECTRICAL DISCONNECTION OF ANY EQUIPMENT BEING DEMOLISHED, EVEN IF NOT EXPLICITLY SHOWN. UNLESS NOTED OTHERWISE, REMOVE ALL DEMOLISHED EQUIPMENT FROM THE PROPERTY.
1. DEMOLITION SHALL BE AS DESCRIBED HEREIN AND AS SHOWN ON THE CONTRACT DRAWINGS. IDENTIFY ACTIVE UTILITIES, AND AT THE APPROPRIATE TIME, DISCONNECT AND CAP OFF SUCH UTILITIES AND PROVIDE EXPERIENCED PERSONNEL ON SITE DURING GENERAL CONTRACTOR DEMOLITION OPERATIONS TO PERFORM SUCH OPERATIONS AND RESOLVE ISSUES. REMOVE MATERIALS NOTED FOR SALVAGE AND REUSE. IDENTIFY AND MARK WIRING AND DEVICES TO REMAIN FOR THE GENERAL CONTRACTOR.
2. THE CONTRACTOR SHALL REVIEW THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR DEMOLITION REQUIREMENTS AND CARRY OUT HIS WORK IN A COMPATIBLE AND COMPLEMENTARY MANNER. REMOVE ALL WIRING DEVICES, BOXES, FIXTURES, EXPOSED ABANDONED RACEWAYS, HANGARS, ETC., AND THOSE MADE OBSOLETE BY THESE ALTERATIONS AND AS SHOWN ON THE ELECTRICAL DRAWINGS. ALL ITEMS TO BE REMOVED OR MODIFIED MAY NOT BE SHOWN, HOWEVER, THIS CONTRACTOR SHALL REMOVE ANY ELECTRICAL WORK AS REQUIRED BY THE CONSTRUCTION OR AS DIRECTED BY THE GOVERNMENT OR CONTRACTING OFFICER. SURVEY THE AFFECTED AREAS BEFORE SUBMITTING A BID AS ALL EXISTING CONDITIONS CANNOT BE
COMPLETELY DEPICTED ON THE DRAWINGS AND SOME UNUSUAL CONDITIONS MAY EXIST.
3. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION.
4. VERIFY FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS ARE AS SHOWN ON DRAWINGS.
5. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES.
6. DISCONNECT AND/OR DE-ENERGIZE ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL.
7. PROVIDE TEMPORARY AND/OR PERMANENT WIRING AND CONNECTIONS AS SHOWN AND/OR AS REQUIRED BY CONDITIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS, AND WHEN SUCH WORK IS SPECIFICALLY APPROVED BY THE GOVERNMENT AND PERMITTED BY REGULATORY AUTHORITIES, USE
PERSONNEL EXPERIENCED IN SUCH OPERATIONS.
8. EXISTING ELECTRICAL SERVICE: COORDINATE POWER OUTAGES WITH THE GOVERNMENT AND UTILITY COMPANY. MAINTAIN EXISTING SYSTEMS IN SERVICE. DISABLE SYSTEMS ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. OBTAIN PERMISSION FROM THE GOVERNMENT AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE
TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA.
9. CONTINUOUS SERVICE IS REQUIRED ON ALL CIRCUITS AND OUTLETS AFFECTED BY THESE CHANGES, EXCEPT WHERE THE GOVERNMENT WILL PERMIT AN OUTAGE FOR A SPECIFIC TIME. OBTAIN GOVERNMENT CONSENT BEFORE REMOVING ANY CIRCUIT FROM CONTINUOUS
SERVICE.
10. ENDS OF ALL CONDUITS TO REMAIN SHALL BE TIGHTLY PLUGGED TO EXCLUDE DUST AND MOISTURE WHILE THE BUILDING IS UNDER
RENOVATION.
11. SECURE ALL CIRCUITS, RACEWAYS, CABLE AND CONDUCTORS THAT, AS A RESULT FROM THIS CONSTRUCTION, ARE ABANDONED OR UNUSED. REMOVE UNUSED EXPOSED CONDUIT AND WIRING BACK TO POINT OF CONCEALMENT INCLUDING ABANDONED CONDUIT ABOVE ACCESSIBLE CEILINGS. REMOVE UNUSED WIRING IN CONCEALED CONDUITS BACK TO SOURCE OR NEAREST POINT OF USAGE. BLANK ABANDONED KNOCKOUTS IN REMAINING BOXES. INSTALL BLANK PLATES FOR ALL UNUSED OUTLETS THAT WILL REMAIN AS A RESULT OF THIS CONSTRUCTION. ALL SUCH WORK SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES.
12. TRACE OUT EXISTING WIRING THAT IS TO BE RELOCATED OR REMOVED AND PERFORM THE RELOCATION OR REMOVAL WORK AS
REQUIRED FOR A COMPLETE OPERATING AND SAFE SYSTEM.
13. RECONNECT EXISTING CIRCUITS SEPARATED AS A RESULT OF THIS CONSTRUCTION.
14. DELIVER ALL REMOVED AND SALVAGED LIGHTING FIXTURES, WIRING DEVICES, FIRE ALARM DEVICES, SPEAKERS, ETC., TO THE GOVERNMENT, OR AT THE GOVERNMENT'S OPTION, DISPOSE OF PROPERLY OFF SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL REGULATIONS. FEES ASSOCIATED WITH DISPOSAL SHALL BE INCLUDED IN THE CONTRACTOR'S BASE BID.
15. COORDINATE WITH THE OTHER TRADES, PRIOR TO BID, AND INCLUDE IN THE BASE BID THE ELECTRICAL DISCONNECTION OF ANY EQUIPMENT BEING DEMOLISHED, EVEN IF NOT EXPLICITLY SHOWN. UNLESS NOTED OTHERWISE, REMOVE ALL DEMOLISHED EQUIPMENT
FROM THE PROPERTY AND IDENTIFIED IN THE ELECTRICAL DRAWINGS.
16. THESE DRAWINGS ARE COMPILED BY THE ARCHITECT/ENGINEER FROM THE GOVERNMENT'S RECORD DRAWINGS AND LIMITED FIELD VERIFICATION OF EXISTING CONDITIONS FOR THE PURPOSE OF INDICATING THE WORK REQUIRED AND ARE BELIEVED TO BE CORRECT.
NOTWITHSTANDING, THE CONTRACTOR SHALL VERIFY ALL CIRCUITS, WIRING, CONDUIT, DIMENSIONS, POINTS OF ACCESS AND ALL FIELD CONDITIONS AFFECTING HIS WORK. BEGINNING OF DEMOLITION MEANS THE CONTRACTOR ACCEPTS EXISTING CONDITIONS.
17. THE CONTRACTOR IS RESPONSIBLE FOR DISPOSAL OF ALL LAMPS CONTAINING MERCURY IN A LINED LANDFILL IN ACCORDANCE WITH NC
GEN STATUTE 309.10M.
18. SEE GENERAL NOTES FOR ADDITIONAL REQUIREMENTS.
GENERAL DEMOLITION NOTES
AutoCAD SHX Text
TALLEY & SMITH ARCHITECTURE INC.
AutoCAD SHX Text
P.O. BOX 518 SHELBY, NC 28151-0518
AutoCAD SHX Text
409 EAST MARION ST. SHELBY, NC 28150
AutoCAD SHX Text
DES.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SATISFACTORY TO:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
CODE IDENT. NO.
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text 80091
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text 023311
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text W.
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text
SEAL
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text P
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text H
E
INTERIOR/EXTERIOR
REPAIRS BLDG. AS124
CAMP LEJEUNE, NORTH CAROLINA
05-17-0075 N40085-17-D-0859
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com c Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
NC# P-0506
SEE DISCLOSURE OF INFORMATION STATEMENT ON SHEET G-1
JULY 27, 2018
E-3RISER DIAGRAMS
JLG
JLG
WAC
60024434
ELECTRICAL
PANEL 'MDP'
208/120V 3Ø, 4W
'NAME'
'WARNING'
'NAME'
'WARNING'
NOT TO SCALE1 DEMOLITION RISER
PANEL 'A'
208/120V 3Ø, 4W
GRADE
WAREHOUSE E116STORAGE E103 EXTERIOR
4#3/0 & 1#6GND-
2"CND
NOTE:
1. SHORT CIRCUIT CALCULATION COMPLETED ON 07/14/2018. BASED ON 3 - 25KVA POLE MOUNTED
TRANSFORMERS 1.5% IMPEDANCE, AND 1.26 X/R. WITH 55 FEET OF SERVICE ENTRANCE CONDUCTOR.
VERIFY ACTUAL PARAMETERS WITH UTILITY COMPANY PRIOR TO INSTALLATION
2. SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED WITH MAX. AVAILABLE FAULT CURRENT, INCLUDING
THE DATE THE FAULT CURRENT CALCULATIONS WERE PERFORMED, PER NEC 110.24
AVAILABLE
FAULT
CURRENT
10,550 AMPS
NOT TO SCALE2 RISER
'NAME'
'WARNING'
'NAME'
'WARNING'
PANEL MDP
208/120V 3Ø, 4W, 400A
PANEL 'SHOP'
208/120V 3Ø, 4W, 200A
GRADE
WAREHOUSE R116WOOD SHOP R109 EXTERIOR
4#500mcm
4"CND
E-4
E-4
E-4
SEE DRAWING E-5
FOR POLE DETAILS
EGB
E-4
DEMOLITION KEYED NOTES
PANELBOARD: DISCONNECT AND REMOVE FEED CONDUIT AND CONDUCTORS. REMOVE PANEL, BRANCH
CIRCUIT CONDUIT AND CONDUCTORS IN THEIR ENTIRETY.
OVERHEAD SECONDARY: DISCONNECT AND REMOVE CONDUIT, CONDUCTORS AND SUPPORTS IN THEIR
ENTIRETY.
PRIMARY CONDUCTORS: CONTRACTOR SHALL PROTECT DURING DEMOLITION AND CONSTRUCTION FOR
RELOCATION AND RE-USE.
UTILITY POLE & ELECTRICAL EQUIPMENT: CONTRACTOR SHALL REMOVE POLE, POLE MOUNTED
TRANSFORMERS, DISCONNECT, LIGHT FIXTURE, WEATHERHEADS, CONDUITS AND CONDUCTORS IN THEIR
ENTIRETY.
SECONDARY SITE LIGHTING FEED CONDUCTORS: CONTRACTOR SHALL PROTECT DURING DEMOLITION AND
CONSTRUCTION FOR RELOCATION TO NEW POLE AND RE-USE.
OVERHEAD UTILITY TELCOM AND CATV CABLING: CONTRACTOR SHALL PROTECT DURING DEMOLITION AND
CONSTRUCTION FOR RELOCATION TO NEW POLE AND RE-USE.
(X)METER PAN, (X)kWH METER AND (X)CURRENT TRANSFORMERS: CONTRACTOR SHALL REMOVE, STORE
AND PROTECT DURING DEMOLITION AND CONSTRUCTION FOR RE-USE.
KEYED NOTES
(X)METER PAN, (X)kWH METER, (X)CURRENT TRANSFORMERS: CONTRACTOR SHALL INSTALL WIRING ALONG WITH (X)KWH METER, (X)METER BASE AND (X)CURRENT TRANSFORMERS REMOVED AND PROTECTED
DURING DEMOLITION.
PRIMARY CONDUCTORS: CONTRACTOR SHALL RELOCATE EXISTING CONDUCTORS PROTECTED DURING
DEMOLITION TO POLE AND RE-USE.
SECONDARY SITE LIGHTING FEED CONDUCTORS: CONTRACTOR SHALL RECONNECT EXISTING CABLING
PROTECTED DURING DEMOLITION TO POLE AND FEED (X)DOWNSTREAM LIGHT FIXTURES FROM
SECONDARY OF TRANSFORMERS.
OVERHEAD UTILITY TELCOM AND CATV CABLING: CONTRACTOR SHALL RELOCATE EXISTING CABLING
PROTECTED DURING DEMOLITION TO POLE.
44" WEATHERHEAD
SPD
NOTE:
1. SURGE PROTECTION DEVICE (SPD) SHALL
BE MOUNTED TO KEEP LEADS AS SHORT AS
POSSIBLE.
2. SPD SHOWN WITH A 30A, 3 POLE BREAKER IN
PANELBOARD BEING PROTECTED, MAKE
CONNECTION WITH 5#10AWG CONDUCTORS,
IF SPD MANUFACTURER RECOMMENDS
LARGER BREAKER OR LEADS, PROVIDE AT
NO ADDITIONAL COST TO OWNER.
5#10
1"CND
3#500MCM 600V TRIPLEX OH SERVICE
DROP CABLE-NEUTRAL SUPPORTED
25kVA
TRANSFORMER(TYP)
AutoCAD SHX Text
TALLEY & SMITH ARCHITECTURE INC.
AutoCAD SHX Text
P.O. BOX 518 SHELBY, NC 28151-0518
AutoCAD SHX Text
409 EAST MARION ST. SHELBY, NC 28150
AutoCAD SHX Text
DES.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
SATISFACTORY TO:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
CODE IDENT. NO.
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text 80091
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text 023311
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text W.
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX…