ATTACHMENT C RE BASELINE ASBESTOS ASSESSMENT SURVEY BUILDING PLANS.docx
DOCX document 16 MB Posted
- Solicitation number
- 36C24824Q1221
About this file
This document appears to be an attachment titled "ATTACHMENT C RE BASELINE ASBESTOS ASSESSMENT SURVEY BUILDING PLANS" related to the federal contract opportunity "F107--FY24 Re-Baseline Asbestos Survey for Lake Baldwin".
The key details are:
- The opportunity is a solicitation issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 8.
- It requires a baseline asbestos assessment survey and building plans for the Lake Baldwin facility.
- The document does not provide specifics on the required products or services, response dates, award details, pricing terms, or set asides. It appears to be architectural plans or drawings rather than a statement of work or other procurement-focused documentation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02 36C24824Q1221 0004.docx | DOCX document | |
| 36C24824Q1221 0002.docx | DOCX document | |
| 36C24824Q1221 0003.docx | DOCX document | |
| 36C24824Q1221 0002.docx | DOCX document | |
| 36C24824Q1221 0002.docx | DOCX document | |
| 52.212-1 ADDENDUM to FAR 52.docx | DOCX document | |
| Revised STATEMENT OF WORK Asbestos .docx | DOCX document | |
| 2010 Lakemont Campus Asbestos Report .pdf | ||
| S06 GOVERNMENT RESPONSE TO CONTRACTORS QUESTIONS.docx | DOCX document | |
| 36C24824Q1221 0002.docx | DOCX document | |
| S02 36C24824Q1221 0001.docx | DOCX document | |
| 36C24824Q1221.docx | DOCX document | |
| ATTACHMENT B 2014 LAKE BALDWIN BLDG 502 ASBESTOS SURVEY.pdf | ||
| ATTACHMENT D VHA DIRECTIVE 7714 ASBESTOS MANAGEMENT PROGRAM.pdf | ||
| 36C24824Q1221.docx | DOCX document | |
| ATTACHMENT A 2014 LAKE BALDWIN BLDG 500 ASBESTOS SURVEY.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Orlando VA Healthcare System Re-Baseline Asbestos Assessment Survey Building Plans.
i. Table 1. Clin 1 Location:
| Building Number |
| Building Name / Description |
| Estimated Square Footage. |
| Attachments. |
| 500 |
| Lake Baldwin - Main Campus / Main Clinic. |
| 21,4190 |
| 501 |
| Lake Baldwin – Warehouse. |
| 15,201 |
| 502 |
| Lake Baldwin - Boiler/Generator Plant. |
| 8,509 |
| 504 |
| Lake Baldwin – Primary Clinics. |
| 19,404 |
ii. Table 2. Clin 2 Locations:
| Building Number |
| Building Name / Description |
| Estimated Square Footage. |
| Attachments. |
| 517 |
| Lake Baldwin – Maintenance Shop. |
| 1,385 |
| 518 |
| Lake Baldwin – Medical Gas storage. |
| 450 |
| 519 |
| Lake Baldwin – Domiciliary Bldg. 1 |
| 11,448 |
| 520 |
| Lake Baldwin – Domiciliary Bldg. 2 |
| 11,448 |
| 521 |
| Lake Baldwin – Domiciliary Bldg. 3 |
| 11,448 |
| See the attachments above in Bldgs. 519 - 520. |
| 522 |
| Lake Baldwin – Domiciliary Bldg. 4 |
| 11,448 |
| See the attachments above in Bldgs. 519 - 520. |
| 3125 |
| Lake Baldwin – Engineering Storage. |
| 534 |
| 3126 |
| Lake Baldwin – Volunteer / FLA / Biomed. |
| 2,627 |
| 3127 |
| Lake Baldwin – Grounds Keeping Building. |
| 540 |
| 3128 |
| Lake Baldwin – Domiciliary / IRMS. |
| 1,929 |
| 3129 |
| Lake Baldwin – Environmental Management Services (Housekeeping). |
| 2,175 |
| 3132 |
| Lake Baldwin – Engineering Administration. |
| 1,961 |
| 3133 |
| Lake Baldwin - Carpentry, Lock Smith, Offices. |
| 2,475 |
| 3134 |
| Lake Baldwin - ENG SHOPS- Plumbing & Electrical. |
| 2,839 |
| 2500 |
| Lakemont Campus. |
| 148,559 |
Lake Baldwin Bldg 502 Floor Plan.pdf image4.emf
Lake Baldwin Bldg 504 Floor Plan.pdf
VHAORLStallR
Sticky Note
Orange Team
Purple Team
Teal Team image5.emf
LB Bldg 517.pdf image6.emf
LB Bldg 518.pdf image7.emf
Dom 2 Floor.pdf image8.emf
Dom 3 Floor.pdf image9.emf
Dom 1 Floor.pdf image10.emf
LB Bldg 3125.pdf image11.emf
LB Bldg 3126 Construction Drawings.pdf
U C
F R
I D
G E
M I
O
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A103
ARCHITECTURAL FINISH PLANS
AND DETAILS
A i l e
P a t h
DESIGN DEVELOPMENT
NON SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BUILDING 3126
ORLANDO VA
675-19-105
Building 3126 Project Director
08/14/2019 KRL JLCRevisions: Date:
C.A.G. Caribeño
Architectural Group, Inc.
1250 W. EAU GALLIE BLVD, SUITE F.
MELBOURNE, FL 32935
PH (321) 622-6900
FAX (321) 622-6901
CONTACT: KENNETH R. LEBRON, AIA
KennethL@cag-architecs.com www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026 KENNETH R. LEBRON, AIA
Florida License #AR0017819
AD101
ARCHITECTURAL DEMO PLAN AND
NOTES
i l h
DESIGN DEVELOPMENT
Building 3126 Project Director
08/14/2019 KRL JLCRevisions: Date:
KENNETH R. LEBRON, AIA
Florida License #AR0017819
PH: 321.345.9026
FACP
FLORIDA CERTIFICATE #AR 0017819
13 E. MELBOURNE AVE. UNIT C
MELBOURNE, FL 32901
PHONE (321) 327-5960 FAX (321) 914-3991
VA FORM 08 - 6231
100% CONSTRUCTION
DOCUMENTS
:\U se rs
\c va nm et er .A
BO
VE
P\ oc um en ts
\0 ov at
Bu ild in g
EP
FP
_c
PN
X8
X.
rv
/2 7/
:4
0:
ED-101
ELECTRICAL - POWER BLDG 3126 -
DEMO BUILDING 3126
11/27/19 AG CVMRICHARD E. COBURN, P.E.
FL License #32820
CODED NOTES:
1. DISCONNECT AND REMOVE ALL ELECTRICAL, FIRE ALARM, ETC. DEVICES FROM AREA
INDICATED, UNLESS OTHERWISE NOTED. REMOVE CONDUIT AND CONDUCTORS BACK TO NEXT
DEVICE OR JUNCTION BOX ON CIRCUIT THAT IS NOT BEING REMOVED. CONTRACTOR SHALL
VERIFY THAT ALL REMAINING CIRCUITS ARE ELECTRICALLY CONTINUOUS. CONTRACTOR SHALL
PROVIDE CONDUCTORS, CONDUIT AND JUNCTION BOXES AS REQUIRED TO KEEP REMAINING
DEVICES OPERATIONAL DURING DEMOLITION. IF NO OTHER DEVICES REMAIN ON CIRCUIT,
REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE. SWITCH BREAKER TO OFF POSITION
AND MARK BREAKER AS "SPARE". REFER TO ARCHITECTURAL PLANS FOR EXTENTS OF
DEMOLITION.
2. EXISTING FIRE ALARM CONTROL PANEL AND ASSOCIATED BACKUP SYSTEM SHALL REMAIN AS
INSTALLED.
3. EXISTING PANEL TO REMAIN AS INSTALLED.
4. DISCONNECT AND REMOVE ELECTRICAL CONNECTION FROM MECHANICAL EQUIPMENT BACK TO
SOURCE. SWITCH BREAKER TO OFF POSITION AND MARK BREAKER AS "SPARE". REFER TO
MECHANICAL PLANS FOR EXTENTS OF DEMOLITION.
5. MECHANICAL EQUIPMENT AND ASSOCIATED ELECTRICAL DISCONNECT IS EXISTING TO REMAIN
AS INSTALLED.
6. EXISTING GROUND BAR TO REMAIN AS INSTALLED.
7. EXISTING DISCONNECT TO REMAIN AS INSTALLED.
8. DISCONNECT AND REMOVE EXISTING SURGE PROTECTION DEVICE.
9. DISCONNECT EXISTING TO REMAIN BRANCH CIRCUITS FROM PANEL AND MAKE READY FOR
CONNECTION TO NEW PANEL IN SAME LOCATION. DISCONNECT PANEL FEEDERS AND REMOVE
PANEL. TURN PANEL OVER TO COTR.
NOT FOR CONSTRUCTION
1/4" = 1'-0"1 ELECTRICAL BLDG 3126-DEMO
XX
N
0 2' 4' 8' 12'
1/4" = 1'-0"
Revisions: Date:
ED-102
ELECTRICAL - LIGHITNG BLDG
3126 - DEMO BUILDING 3126
1/4" = 1'-0"1 LIGHTING BLDG 3126- DEMO
1. DISCONNECT AND REMOVE ALL LIGHTS AND ASSOCIATED LIGHTING CONTROL DEVICES IN THIS
AREA. REMOVE CONDUIT AND CONDUCTORS BACK TO NEXT DEVICE OR JUNCTION BOX ON
CIRCUIT THAT IS NOT BEING REMOVED. CONTRACTOR SHALL VERIFY THAT ALL REMAINING
CIRCUITS ARE ELECTRICALLY CONTINUOUS. CONTRACTOR SHALL PROVIDE CONDUCTORS,
CONDUIT AND JUNCTION BOXES AS REQUIRED TO KEEP REMAINING DEVICES OPERATIONAL
DURING DEMOLITION. IF NO OTHER DEVICES REMAIN ON CIRCUIT, REMOVE CONDUIT AND
CONDUCTORS BACK TO SOURCE. SWITCH BREAKER TO OFF POSITION AND MARK BREAKER AS
"SPARE". REFER TO ARCHITECTURAL PLANS FOR EXTENTS OF DEMOLITION.
2. EXISTING PANEL TO REMAIN AS INSTALLED.
SHELVES
K-3427HIG HLINETO ILETSVITREO US CHINA
K-2861HUDSONC_LAVATORYCAST IRON
K-3427HIGHLINE TOILETS VITREOUS CHINA
IC
FR
IG
MO
MO MOMO
33a
3a 3
A2N
A1N
A2E A2
A2 A2
A2 A2E
A2E A2
A2 A2
A2 A1N A1N A1N A1N
A2E A2 A2
A2 A2 A2
A2 A2 A2E
J2E
A2N A2NE
A2NE
A1N
A2NE A2N
PL1-5
X X X X
X
PL1-5 PL1-5
PL1-5 PL1-5
PL2-14 PL2-14 PL2-14
PL2-14
PL2-14 PL2-14
PL1-5 PL2-14 PL2-14 PL2-14
PL2-14 PL2-14
PL1-5 PL1-5 PL2-14 PL2-14
b b a a
1 1 1
1 11
FE FE FE FE
PL1-3 PL1-3 PL1-3 PL1-3
FE
PL1-3
STORAGE 102
OFFICE
VOLUNTEER
VOLUNTER
WORK
MECH ROOM
BIOMED
I.T.
TOILET
FL STATE
UNION OFFICE
STORAGE
PL2
EL-101
ELECTRICAL - LIGHTING BLDG
3126 - NEW BUILDING 3126
1/4" = 1'-0"1 LIGHTING BLDG 3126- NEW
1. LIGHTING CONTROLS IN THIS ROOM SHALL BE CONFIGURED FOR MANUAL ON,
MANUAL/VACANCY OFF OPERATION. VACANCY SENSORS SHALL BE CONFIGURED FOR 20
MINUTE TIME OUT PERIOD.
2. LIGHTING CONTROLS IN THIS AREA SHALL BE CONFIGURED FOR AUTO ON, AUTO OFF
OPERATION. OCCUPANCY SENSORS SHALL BE CONFIGURED FOR 30 MINUTE TIME OUT PERIOD.
3. COORDINATE EXACT LOCATION OF FIXTURE WITH DUCT WORK PRIOR TO CONSTRUCTION.
N 0 2' 4' 8' 12'
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION MANUFACTURER MODEL VOLTAGE LAMP TYPE VA COMMENTS
A1N 2x2 FLAT PANEL LED LIGHT FIXTURE. 3400 LUMEN MINIMUM, 4000K COLOR TEMPERATURE, 80CRI MINIMUM.
WITH NLIGHT CAPABILITIES ON BOARD.
ACUITY BRANDS EPANL 2X2 3400LM 80CRI 40K MIN1
NLIGHT MVOLT
120 V LED 34 VA
A2 2x4 FLAT PANEL LED LIGHT FIXTURE. 3000 LUMEN MINIMUM, 4000K COLOR TEMPERATURE, 80CRI MINIMUM. ACUITY BRANDS EPANL 2X4 3000LM 80CRI 40K MIN1 ZT
MVOLT
120 V LED 30 VA
A2E 2x4 FLAT PANEL LED LIGHT FIXTURE. 3000 LUMEN MINIMUM, 4000K COLOR TEMPERATURE, 80CRI MINIMUM.
WITH INTEGRAL EMERGENCY BATTERY PACK.
ACUITY BRANDS EPANL 2X4 3000LM 80CRI 40K MIN1 ZT
MVOLT E10WCP
A2N 2x4 FLAT PANEL LED LIGHT FIXTURE. 3000 LUMEN MINIMUM, 4000K COLOR TEMPERATURE, 80CRI MINIMUM.
WITH NLIGHT CAPABILITIES ON BOARD.
ACUITY BRANDS EPANL 2X4 3000LM 80CRI 40K MIN1
NLIGHT MVOLT
A2NE 2x4 FLAT PANEL LED LIGHT FIXTURE. 3000 LUMEN MINIMUM, 4000K COLOR TEMPERATURE, 80CRI MINIMUM.
WITH INTEGRAL EMERGENCY BATTERY PACK AND NLIGHT CAPABILITIES ON BOARD.
ACUITY BRANDS EPANL 2X4 3000LM 80CRI 40K MIN1
NLIGHT MVOLT E10WCP
FE WALL MOUNTED, TRAPAZOIDAL EXTERIOR LIGHTING FIXTURE, LED, 4000 K, FORWARD THROW DISTRIBUTION, WITH INTGRAL LIGHT/MOTION SENSOR, UL WET LOCATION LISTED, INTEGRAL EMERGENCY
BATTERY PACK.
ACUITY BRANDS WST LED P2 40K VF 120 PIR1FC3V
E20WH DDBXD
120 V LED 36 VA MOUNT AT 9'-0" AFF TO BOTTOM OF FIXTURE
OR AS OTHERWISE NOTED ON PLAN SHEETS.
J2E 4', LED, SURFACE MOUNTED LINEAR FIXTURE. 4000K COLOR TEMPERATURE, 80CRI MINIMUM, 3000 LUMENS
MINIMUM. WITH INTEGRAL EMERGENCY BATTERY PACK.
ACUITY BRANDS ZL1D L48 3000LM FST MVOLT 40K 80CRI
E10WLCP WH
X RECESSED EDGE LIT LED EXIT SIGN, CEILING MOUNTED, RED LETTERS, CLEAR BACKGROUND AND SINGLE
OR DOUBLE FACE
ACUITY BRANDS EDGR 1 R EL SD 120 V LED 10 VA
K-3427HIGHLINE TOILETSVITREOUS CHINA
SD
SDSD
SD SD SD
SD SD
P P P P P
J
M M M
2TYPICAL
5 55 5
PL1-6
PL1-11
PL1-9
PL1-17
PL1-14
PL2-2
PL2-4
PL1-15
PL1-12
PL1-12
PL2-8
PL2-8
PL1-7
PL1-7
PL1-10
PL2-3
PL2-11
PL2-9
PL1-2 PL1-2 PL1-4 PL1-4
PL2-5
PL2-7
PL2-5
PL2-7
PL1-13
PL2-6 PL2-6 PL2-6
PL2-12
WPPL1-12
WP
FACP
PL2-1
3126-ODU 1
3126-(E)CU 2
3126-(E)CU 1
3126-(E)AHU 1
3126-(E)AHU 2
PL2-13,15
PL1-23,25
PL1-27,29
30AR
30AF
3R
PL1-13126-(E)EWH 1
3126-EF 2 3126-EF 3 3126-EF 4
PL2-16 PL2-16
PL2-16
101010
PL2-16
3126-EF 1
3126-CP 1 PL1
PL1-8
PL1-8
PL2-10
30AR
20AF
3R
PL1-16
EXISTING
FIRE ALARM
CONTROL
PANEL
"FACP"
ADDRESSABLE FIRE
ALARM PANEL WITH
BATTERY BACK UP
EXISTING DIALER,
PROVIDE DEDICATED
TELEPHONE
CONNECTION
GROUND FLOOR
R R
TYPICAL CONTROL RELAYS
INDICATING DEVICES
TYPICAL INITIATION DEVICES
ROOF
SDHD
EP-101
ELECTRICAL - POWER BLDG 3126 -
NEW BUILDING 3126
1/4" = 1'-0"1 ELECTRICAL BLDG 3126- NEW
1. LOCAL MAINTENANCE DISCONNECT, COORDINATE EXACT LOCATION WITH MECHANICAL
EQUIPMENT PRIOR TO CONSTRUCTION. IDU POWER FED FROM ASSOCIATED ODU. PROVIDE
CONDUIT AND CABLES AS REQUIRED BY MANUFACTURERS INSTALLATION INSTRUCTIONS FOR A
CODE COMPLIANT INSTALLATION.
2. PROVIDE NEW FIRE ALARM INITIATION AND NOTIFICATION DEVICES. CONNECT NEW FIRE ALARM
DEVICES TO EXISTING FIRE ALARM CONTROL PANEL. NEW DEVICES SHALL BE COMPATIBLE
WITH EXISTING FIRE ALARM SYSTEM. EXISTING FIRE ALARM SYSTEM IS SIMPLEX 4100U FIRE
CONTROL.
3. EXISTING MAIN ELECTRICAL GROUND BAR.
4. NEW TELECOMMUNICATIONS MAIN GROUND BUSBAR. REFER TO SHEET T-501 FOR MORE
INFORMATION.
5. TOP OUTLET(S) OF DUPLEX AND DOUBLE DUPLEX RECEPTACLES INDICATED SHALL BE
CONNECTED TO THE PLUG LOAD CONTROLLED POWER PACK VIA THE VACANCY SENSOR
LOCATED IN THE ROOM. CONTROLLED OUTLETS SHALL BE IDENTIFIED PER NEC 406.3(E).
OUTLETS SHALL BE DE-ENERGIZED WHEN SENSOR TIMES OUT AND SWITCHES LIGHTS OFF.
REFER TO PLUG LOAD CONTROL DIAGRAM ON SHEET E-502 FOR MORE INFORMATION.
6. EXISTING EQUIPMENT TO REMAIN AS INSTALLED.
7. EXISTING MECHANICAL EQUIPMENT. EXISTING CIRCUITS TO REMAIN AS INSTALLED.
8. (2)#10AWG CU, #10AWG CU GROUND IN 3/4" CONDUIT.
9. (2)#6AWG CU, #10AWG CU GROUND IN 3/4" CONDUIT.
10. LOCAL MAINTENANCE DISCONNECT. COORDINATE EXACT LOCATION WITH MECHANICAL
EQUIPMENT PRIOR TO CONSTRUCTION. EXHAUST FAN SHALL BE INTERLOCKED LOCAL LIGHTING
CONTROLS. REFER TO SHEET E-502 FOR MORE INFORMATION.
11. DUPLEX OUTLET FOR CONNECTION OF OVER COUNTER MICROWAVE. COORDINATE EXACT
LOCATION AND MOUNTING HEIGHT IN FIELD AND WITH ARCHITECTURAL DRAWINGS PRIOR TO
CONSTRUCTION.
N 0 2' 4' 8' 12'
N.T.S2 FIRE ALARM RISER DIAGRAM
1 EXIT SIGN MOUNTING - GYPBOARD CEILING
NTS
WIRE TIE THROUGH
MOUNTING CHANNEL
& CROSS BEAM, TYP.
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
DRYWALL CEILING
CROSS TEE, TYP.
GYPSUM
BOARD
CEILING MAIN
BEAM.
6.35mm (1/4") SCREW
LOCKING SQUARE
WASHER & NUT
JUNCTION BOX
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
HANGER WIRE AND MOUNTING
CHANNEL ATTACHED TO STRUCTURE
REFER TO SPECIFICATION SECTION
26 51 00 DRYWALL CEILING
CROSS TEE, TYP.
CEILING HANGER WIRE
2 EXIT SIGN MOUNTING - LAY-IN CEILING
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING
INSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
ARCHITECTURAL
CEILING GRID
ACOUSTICAL
CEILING
TILE (TYP)
WIRE TIE THROUGH
MOUNTING CHANNEL
& CROSS BEAM, TYP.
HANGER WIRE AND MOUNTING CHANNEL
ATTACHED TO STRUCTURE REFER TO
SPECIFICATION SECTION 26 51 00
FIXTURE WHIP FROM JUNCTION
BOX (1829mm (6') LONG MAX)
CEILING HANGER WIRE
WASHER & NUT
6.35mm (1/4") SCREW
3 FLOOR SLAB PENETRATION DETAIL
9.52mm
(SIZE AS REQUIRED)
CONDUIT FITTING
SPRING
NUT, TYP
FLOOR SLAB,
TYP.
FIRESTOP SEALANT
PER SECTION 07 84 00,
FIRESTOPPING
CONDUIT, TYP MINERAL WOOL
(FIRMLY PACKED)
INTEGRAL GALVANIZED
LIPPED STEEL MOUNTING
CHANNEL, TYP.
STEEL EXPANSION
ANCHOR, TYP
(3/ 8") M AX
4 CONDUIT TRAPEZE MOUNTING DETAIL
CONDUIT CLAMP.
SIZE AS REQUIRED
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
REFER TO PLANS FOR
QUANTITY & SIZE OF
CONDUITS
GENERAL NOTES:
1. INTEGRAL GALVANIZED LIPPED STEEL MOUNTING
CHANNEL LONGER THAN 915mm (36") SHALL BE
INSTALLED WITH A CENTER SUPPORT ROD.
2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED
METHOD PER SPECIFICATION 26 05 33, RACEWAY AND
BOXES FOR ELECTRICAL SYSTEMS. FIELD VERIFY EXACT
CONDITIONS.
3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER
TO SPECIFICATION SECTION 13 05 41, SEISMIC
RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL
COMPONENTS.
WASHER & LOCKNUT
9.52mm (3/8") MIN
GALVANIZED THREADED
ROD, TYP.
INTEGRAL
LIPPED STEEL
MOUNTING
CHANNEL
WASHER & LOCKNUT
LE NGTH AS REQU IRED
5 GROUNDING BAR DETAIL
(2 m
(4
( 1")
25mm (1")
(1")
(2")
51mm
(1 1/ 2") TYP
38mm
(1
(5
8")
6.35mm
(1/4") DIA.
MOUNTING
HOLES TYP. OF
(4)
BASE
CLAMP/
BRACKET
9.52mm (3/8")
DIA. HOLE TYP.
OF (6)
9.52mm (3/8") x 16mm (5/8")
HEX HEAD BOLT
9.52mm (3/8") LOCK WASHER
9.52mm (3/8") FLAT WASHER & 9.52mm (3/8") LOCK WASHER
6.35mm
(1/4") THICK
CU BAR
(2'- 0") MI N
610mm
6.35mm (1/4")
DIA. HOLE TYP
OF (8)
GENERAL NOTES:
1. ALL HARDWARE SHALL BE STAINLESS STEEL.
2. PROVIDE 1 MOUNTING POINT PER 305mm (12") OF BAR LENGTH.
3. HOLES MAY BE ADDED IF REQUIRED.
SECTION
STEEL
EXPANSION
ANCHOR
INSULATOR
9.52mm (3/8") FLAT WASHER
E-501
ELECTRICAL DETAILS BUILDING 3126
Section A-A
1A 1B
SPECIFIED TECHNOLOGIES INC- SPECSEAL LCI SEALANT
* INDICATES SUCH PRODUCTS SHALL BEAR THE UL
OR CUL CERTIFICATION MARK FOR JURISDICTIONS
EMPLOYINGTHE UL OR CUL CERTIFICATION (SUCH AS
CANADA), RESPECTIVELY.
SYSTEM NO. W-L-5122
1. WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE
CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES
WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING
CONSTRUCTION FEATURES:
A.
STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL
CHANNEL STUDS. WOOD STUDS
TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND
SPACED MAX 24 IN. OC.
B. GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL
WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 7-1/2 IN.
THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL
ASSEMBLY IN WHICH IT IS INSTALLED.
2. THROUGH PENETRANT - ONE METALLIC PIPE OR TUBE TO BE INSTALLED ECCENTRICALLY OR CONCENTRICALLY
WITHIN THE FIRESTOP SYSTEM. PIPE OR TUBE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL
ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES AND TUBES MAY BE USED:
A. STEEL PIPE - NOM 4 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE - NOM 4 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. COPPER PIPE - NOM 2 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
D. COPPER TUBE - NOM 2 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE.
3. TUBE INSULATION - PLASTICS# - NOM 3/4 IN. THICK ACRYLONITRILE BUTADIENE/POLYVINYL CHLORIDE (AB/PVC)
FLEXIBLE FOAM FURNISHED IN THE FORM OF TUBING. ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO
MAX 1-1/2 IN.
SEE PLASTICS (QMFZ2) CATEGORY IN THE PLASTICS RECOGNIZED COMPONENT DIRECTORY FOR NAMES OF
MANUFACTURERS. ANY RECOGNIZED COMPONENT TUBE INSULATION MEETING THE ABOVE SPECIFICATIONS
AND HAVING A UL 94 FLAMMABILITY CLASSIFICATION OF 94-5VA MAY BE USED.
4. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN
ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT POINT CONTACT LOCATION, MIN 1/4 IN. DIAM
BEAD OF FILL MATERIAL APPLIED AT INSULATED METALLIC PIPE/GYPSUM BOARD INTERFACE ON BOTH
SURFACES OF WALL.
1/16" THICK WHITE PLASTIC
WITH COLORED FACE PER
SPECIFICATIONS
1/2" HIGH LETTERING FOR
EQUIPMENT NAME
1/4" HIGH LETTERING FOR
REMAINING TEXT
ADHESIVE BACKING WHEN
INSTALLED IN CONDITIONED
SPACES
EQUIPMENT VOLTAGE
EQUIPMENT NAME
FASTEN WITH BRASS SCREWS
WHEN LOCATED IN NON-
CONDITIONED OR EXTERIOR
EQUIPMENT SOURCE
(PANEL & CIRCUIT)
120V, 1PH
FED FROM "MDP-4"
AHU-X
AHU-X
240V, 1PH
FED FROM "MDP-4"
120/240V, 1PH, 3W
FED FROM PANEL "XXXX"
VIA T-XXX
TYPICAL 120/240V PANELBOARD
PANEL "XXXX"
1/16" THICK WHITE PLASTIC
WITH COLORED FACE PER
SPECIFICATIONS
1/2" HIGH LETTERING FOR
PANELBOARD NAME
1/4" HIGH LETTERING FOR
REMAINING TEXT
ADHESIVE BACKING WHEN
INSTALLED IN CONDITIONED
80"
48"
90"
54"
18" AFF
6" AFC
36"
AFF
FIRE HORN (OR CHIME) &
LIGHT 80" AFF FROM
BOTTOM OF DEVICEEXIT
DUPLEX
RECEPTACLE
CENTERED BETWEEN
DOOR & CEILING
(COORDINATE WITH
ARCHITECT)
CENTERED OVER
DOOR (WHERE
APPLICABLE)
FA PULL STATION
SWITCH
TELE. OUTLET
CLOCK
OUTLET
VOLUME
CONTROL
SPECIAL POWER OUTLET
FINISHED FLOOR
DUPLEX RECEPTACLE
REMOTE TEST
VC
COMPUTER
OUTLET
RT
TELE. OUTLET
TELEVISION OUTLET42" A.F.F. W/ 36" COUNTER,
39" A.F.F. W/ 30" COUNTER,
48" A.F.F. WITHOUT COUNTER
78" MAX. TO
TOP DEVICE
OR AS NOTED ON PLANS
WALL MOUNTED LIGHT
FIXTURES AS NOTED ON
PLANS
PANELBOARD
L
CL
CL CL
STUD TO STUD TELESCOPING BOX SUPPORT, B-
LINE BB2 SERIES OR EQUAL.
CONDUITS
EQUIPMENT
GROUND
CONDUCTOR
GROUND SCREW
ON WIRING DEVICE.
GROUND SCREW
IN OUTLET BOX.
PLASTER RINGNEUTRAL CONDUCTOR
HOT CONDUCTOR
METAL STUD
DRYWALL
PLASTER RING
CONDUIT
4 SQUARE OUTLET BOX
OUTLET BOX SECURED TO BOX
SUPPORT
WIRE NUT (TYP.)
GROUND SCREW IN OUTLET
BOX.
PHASE A
PAHSE B
PHASE C
NEUTRAL
GROUND
BLACK
RED
BLUE
WHITE
GREEN
VOLTAGE
240V/120V
IDENTIFICATION OF GROUNDED CONUCTORS SHALL
BE PERFORMED BASED ON NEC ARTICLE 200.
TO
SOURCE
ID#
B B
G V
PLUG LOAD CONTROL POWER
PACK (1 PACK REQUIRED FOR
EACH RECEPTACLE CIRCUIT BEING
CONTROLLED)
SMALL OFFICES WITH
OCCUPANCY/VACANCY SENSORS AND DIMMING
CONTROL
B B
LIGHTING CONTROL NOTES:
1. RISERS DIAGRAMS ARE TO SHOW DESIGN INTENT FOR
STANDALONE AND NETWORK AREAS.
2. SENSORS AND POWER PACKS MUST OPERATE IN VACANCY
MODE OR OCCUPANCY MODE OF OPERATION.
3. REFER TO FLOOR PLANS FOR QUANTITIES OF CONTROL
DEVICES SUCH AS OCCUPANCY SENSORS, PHOTOCELLS, AND
DIMMER SWITCHES.
4. QUANTITIES OF DIMMING POWER PACKS AND UL924 DIMMING
POWER PACKS REQUIRED PER SWITCH LEGS AND ZONES.
5. ROOM LOCATIONS LISTED BELOW INDICATE GENERAL DESIGN
INTENT BUT ARE NOT LIMITED TO JUST THOSE SPECIFIC
ROOMS.
CAT 5 (LOW VOLTAGE)
CLASS 1 (LINE VOLTAGE)
CLASS 2 (LOW VOLTAGE)
WIRE LEGEND
EQUIPMENT LEGEND
OCCUPANCY/VACANCY SENSOR AND
PHOTOCELL COMBO
MODEL #: nCM PDT 10 ADCX
ON/OFF RAISE/LOWER
DIMMER OVERRIDE SWITCH
MODEL #: Npodm DX
DIMMER/VACANCY DIMMING PACK
MODEL #: NPP16 D SA
PLUG LOAD CONTROL POWER PACK
MODEL #: NPP20 PL
SENSORSWITCH nLight
RESTROOMS EXHAUST FAN INTERLOCKED WITH
OCCUPANCY SENSORS
LIGHTING CONTROL NOTES:
1. SENSORS AND POWER PACKS MUST OPERATE IN VACANCY
MODE OR OCCUPANCY MODE OF OPERATION.
2. REFER TO FLOOR PLANS FOR QUANTITIES OF CONTROL DEVICES
SUCH AS OCCUPANCY SENSORS, PHOTOCELLS, AND CONTROL
SWITCHES.
3. QUANTITIES OF POWER PACKS REQUIRED PER SWITCH LEGS
AND ZONES.
EXHAUST
FAN
H
RESTROOM
LIGHTS
SWITCHING AND 0-10V DIMMING
PACK MODEL #: nPP16 D
EQUIPMENT LEGEND
DIMMER/OCCUPANCY/VACANCY WALL
SWITCH COMBINATION UNIT
MODEL #: WSX PDT D
SENSORSWITCH nLight
CAT 5 (LOW VOLTAGE)
CLASS 1 (LINE
VOLTAGE)
WIRE LEGEND
E-502
ELECTRICAL DETAILS BUILDING 3126
N.T.S.
CONDUIT PENETRATION OF FIREWALL1 N.T.S.
EQUIPMENT NAMEPLATE2 N.T.S.
PANELBOARD NAMEPLATE3
TYPICAL MOUNTING HEIGHTS4 N.T.S.
TYPICAL RECEPTACLE MOUNTING DETAIL5
WIRE COLOR CHART6
PLUG LOAD/LIGHTING CONTROL DIAGRAM7 N.T.S.
LIGHTING CONTROL DIAGRAM8
SWITCH, MULTIPOSITION
SWITCH, NORMALLY CLOSED FLOAT
SWITCH, NORMALLY CLOSED FOOT OPERATED
SWITCH, NORMALLY CLOSED LIMIT
SWITCH, NORMALLY CLOSED TIME DELAY
SWITCH, NORMALLY CLOSED TEMPERATURE ACTIVATED
SWITCH, NORMALLY OPEN FLOAT
SWITCH, NORMALLY OPEN LIMIT
SWITCH, NORMALLY OPEN TEMPERATURE ACTIVATED
SWITCH, NORMALLY OPEN TIME DELAY
SWITCH, SINGLE BREAK
FUSE WITH RATING
NORMALLY CLOSED RELAY CONTACT
NORMALLY OPEN RELAY CONTACT
MOLDED CASE CIRCUIT BREAKER
LOW-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
HIGH-VOLTAGE OIL CIRCUIT BREAKER
HIGH-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
SWITCH AND FUSE UNIT
FUSED DRAWOUT POTENTIAL TRANSFORMER
ELECTRICAL SYMBOLS - DIAGRAM
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
DELTA CONNECTION
TRANSFORMER
WYE CONNECTION
EARTH GROUND
PULL BOX
PRESSURE SWITCH-CLOSE ON INCREASE
PRESSURE SWITCH-OPEN ON INCREASE
FUSIBLE LINK
TIME CLOCK
GENERATOR, POWER
BATTERY
CAPACITOR
LIGHTNING ARRESTOR
RECTIFIER, CATHODIC PROTECTION SANITARY
RELAY
50 = INSTANTANEOUS OVERCURRENT OR
RATE-OF-RISE
51 = AC-TIME OVERCURRENT
67 = AC-DIRECTIONAL OVERCURRENT
86 LOCKING OUT
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
POTHEAD
STRESS CONE
METER
AMMETER
VOLTMETER
WATTMETER
WATT-HOUR METER
PB
TC
V
W
WH
ABC
PANEL MAIN CIRCUIT BREAKER TYPE
### - INDICATES BREAKER RATING
ABC - INDICATES PANEL DESIGNATION
ABC
PANEL MAIN LUG TYPE
### - INDICATES BUS RATING
ABC - INDICATES PANEL DESIGNATION
###A ENCLOSED CIRCUIT BREAKER
### - INDICATES BREAKER RATING
GND GROUND BUS BAR
EMERGENCY PUSH BUTTON
NC NC - NORMALLY CLOSED
NO - NORMALLY OPEN
SHUNT TRIP CIRCUIT BREAKER
SURGE PROTECTION DEVICESPD
PL1
NEW PANEL
SPD
EXISTING PANEL
EXISTING PANEL FEEDER
REPLACE EXISTING SURGE
PROTECTION DEVICE (SPD) WITH
NEW SPD
NEW BREAKER
NEW (3) #300KCMIL AL, #300KCMIL
AL NEUTRAL CONDUCTORS SPLICED
INTO NEW ARIAL 3-PHASE UTILITY
CONDUCTORS IN NEW 2-1/2"
CONDUIT AND WEATHER HEAD.
NEW (3) #3/0AWG AL, #
3/0AWG AL NEUTRAL ARIAL
CONDUCTORS SPLICED INTO
EXISTING ARIAL 3-PHASE
UTILITY CONDUCTORS AT
EXISTING POWER POLE.
SPLICE AND DRIP LOOP
SPD
NEW SPD
E-901
ELECTRICAL DIAGRAMS BUILDING 3126
N.T.S1 PARTIAL NORMAL POWER ONE-LINE DIAGRAM
Notes:
Total Est. Demand Current: 49 A Receptacle 6.8 kVA 100.00% 6.8 kVA Total Conn. Current: 47 A Other 0.2 kVA 100.00% 0.2 kVA Total Est. Demand: 10.3 kVA Lighting 0.7 kVA 100.00% 0.7 kVA Total Conn. Load: 9.8 kVA HVAC 2.1 kVA 125.00% 2.6 kVA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 46 A 48 A Total Load: 4.8 kVA 5.0 kVA
19 0.0 kVA 0.0 kVA 1 20 A Spare 20
SPD 20 A 2
0.0 kVA 0.0 kVA 1 20 A Spare 18
15 1.0 kVA 0.2 kVA 1 20 A Rest Room Exhaust Fans 16
ODU/IDU-1 20 A 2
1.0 kVA 0.7 kVA 1 20 A Lighting - 106 Thru 113 14
11 Receptacle - Quad IT Rack 107 20 A 1 0.4 kVA 0.2 kVA 1 20 A Receptacle - GFCI Exterior 12 9 Receptacle - Quad IT Rack 107 20 A 1 0.4 kVA 0.4 kVA 1 20 A Receptacle - Qaud 109 10 7 Receptacle - Furniture 111 20 A 1 0.8 kVA 0.4 kVA 1 20 A Receptacle - 107 8 5 Receptacle - Furniture 111 20 A 1 0.8 kVA 0.6 kVA 1 20 A Receptacle - GFCI 108,110,112 6 3 Receptacle - Quad 109,111 20 A 1 1.2 kVA 0.8 kVA 1 20 A Receptacle - 109,111 4 1 EXISTING FACP 20 A 1 0.1 kVA 0.8 kVA 1 20 A Receptacle - 106,109 2
CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT
EXISTING PANEL
Enclosure: Type 1 Mounting: Surface Wires: 3 Mains Rating: 100 A
Supply From: PL1 Phases: 1 Mains Type: MCB Location: IT 107 Volts: 208V/120V A.I.C. Rating:
Branch Panel: PL2
1. Electric heat in AHU and Condensing unit are non concurent loads.
Receptacle 15.4 kVA 82.47% 12.7 kVA Other 0.6 kVA 100.00% 0.6 kVA Total Est. Demand Current: 112 A Lighting - Exterior 0.2 kVA 100.00% 0.2 kVA Total Conn. Current: 114 A Lighting 1.3 kVA 100.00% 1.3 kVA Total Est. Demand: 40.4 kVA HVAC 20.4 kVA 110.77% 22.6 kVA Total Conn. Load: 40.9 kVA Equipment 3.0 kVA 100.00% 3.0 kVA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 119 A 111 A 111 A Total Load: 14.3 kVA 13.3 kVA 13.3 kVA
41 Spare 20 A 1 0.0 0.0 42 39 Spare 20 A 1 0.0 0.0 40 37 Spare 20 A 1 0.0 0.0
3 30 A SPD
35 Spare 20 A 1 0.0 0.0 1 20 A Spare 36 33 5.0 0.0 1 20 A Spare 34
EXISTING PL2 90 A 2
4.8 0.0 1 20 A Spare 32
29 3.8 0.0 1 20 A Spare 30
RELOCATED AHU-2 70 A 2
3.8 0.0 -- -- Space 28
25 0.2 4.4 26
RELOCATED CU-2 30 A 2
0.2 4.4
2 70 A EXISTING - AHU-1
21 EXISTING Grounds Shed 20 A 1 1.5 0.2 22
19 EXISTING EWH1 20 A 1 1.5 0.2
2 60 A EXISTING CU-1
17 Receptacle - Refrig 100 20 A 1 0.2 1.5 1 20 A EXISTING EMS Shed 18 15 Receptacle - Microwave 105 20 A 1 0.2 0.2 1 20 A Receptacle - Microwave 100 16 13 Receptacle - GFCI 100,105,106 20 A 1 0.6 0.2 1 20 A Receptacle - Refrig 105 14 11 Receptacle - 103,105 20 A 1 1.0 0.6 1 20 A Receptacle - 104, Exterior 12 9 Receptacle - 101,100 20 A 1 1.0 0.4 1 20 A Receptacle - Qaud 106 10 7 Receptacle - Quad 103 20 A 1 0.8 0.8 1 20 A Receptacle - Qaud 102 8 5 Lighting - 100 Thru 105 20 A 1 0.6 1.0 1 20 A Receptacle - 100,102 6 3 Lighting - Exterior 20 A 1 0.2 0.8 1 20 A Receptacle - Furniture 100 4 1 CP-1 20 A 1 0.0 0.8 1 20 A Receptacle - Furniture 100 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Enclosure: Type 1 Mounting: Surface Wires: 4 Mains Rating: 225 A
Supply From: Phases: 3 Mains Type: MCB Location: Volts: 120/208 Wye A.I.C. Rating:
Branch Panel: PL1
DUCTWORK SYMBOLS
SYMBOL DESCRIPTION
HVAC ABBREVIATIONS
ABBR. DESCRIPTION ABBR. DESCRIPTION
A/E ARCHITECT / ENGINEER
ACU AIR CONDITIONING UNIT
ACD AUTOMATIC CONTROL DAMPER,MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER,TWO POSITION
AD ACCESS DOOR
AF AFTER FILTER
AFF ABOVE FINISHED FLOOR
AFMD AIR FLOW MEASURING DEVICE
AHU AIR-HANDLING UNIT
AMP AMPERGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CC COOLING COIL
CD-1 CONSTRUCTION DOCUMENTS (SUBMISSION1)
CD-2 CONSTRUCTION DOCUMENTS (SUBMISSION2)
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CH CHILLER
CHW CHILLER WATER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
DB DECIBELS
Db DRY-BULB TEMPERATURE
DD-1 DESIGN DEVELOPMENT (SUBMISSION1)
DD-2 DESIGN DEVELOPMENT (SUBMISSION2)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
ENT ENTERING
ERC ELECTRIC REHEAT COIL
ABBR. DESCRIPTION
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
F FAHRENHEIT
F/SDPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT EXCHANGER
FM FLOW METER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FT FEET
FV FACE VELOCITY
GA GAUGE
GAL GALLONS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HC HEATING COIL
HOA HAND/OFF/AUTOMATIC
HP HORSEPOWER
HSTAT HUMIDISTAT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IN INCHES
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
kW KILOWATT
LAT LEAVING AIR TEMPERATURE
LF LINEAR FOOT (FEET)
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MERV MINIMUM EFFICIENCY REPORTING VALUE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OR OPERATING ROOM
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
R/E RETURN OR EXHAUST
RA RETURN AIR
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RLA RUN LOAD AMPERE
SA SUPPLY AIR
SAD SOUND ATTENUATING DEVICE
SAT SUPPLY AIR TEMPERATURE
SD SMOKE DETECTOR
SD-1 SCHEMATIC DESIGN (SUBMISSION1)
SD-2 SCHEMATIC DESIGN (SUBMISSION2)
SDPR SMOKE DAMPER
SDR SMOKE DAMPER (RETURN)
SDS SMOKE DAMPER (SUPPLY)
SI SQUARE INCHES
SP STATIC PRESSURE
SPS STATIC PRESSURE SENSOR
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
W/ WITH
W/O WITHOUT
LIMIT OF DEMOLITION
DN
DN
UP
UP
SUPPLY DUCT (UP &DOWN)
EXHAUST DUCT (UP & DOWN)
ROUND AND SQUARE 4-WAY
CEILING DIFFUSERS
SUPPLY TOP REGISTER OR GRILLE
(WALL TYPE)
EXHAUST OR RETURN CEILING
REGISTER OR GRILLE
EXHAUST OR RETURN BOTTOM
REGISTER OR GRILLE (WALL TYPE)
EXHAUST OR RETURN REGISTER
OR TOP GRILLE (WALL TYPE)
VANED ELBOW & AIR SPLIT TYPE
DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING
DUCT
INCLINED RISE, IN DIRECTION OF
AIR FLOW
INCLINED DROP, IN DIRECTION OF
AIR FLOW
DNUP RETURN DUCT (UP & DOWN)
SQUARE 3-WAY CEILING
DIFFUSERS
SQUARE 2-WAY CEILING
LINEAR SLOT
DIFFUSER
SQUARE 1-WAY CEILING
BACK DRAFT
DAMPER
BDD
FC
10x8
FLEXIBLE CONNECTION,
EQUIPMENT, VIBRATION,
OR SEISMIC
VANED ELBOW (PROVIDE ALL
SQUARE OR RECTANGULAR
ELBOWS WITH VANES EVEN IF
SYMBOL IS
MISSING)
VANED ELBOW (SHORT RADIUS)
STANDARD RADIUS ELBOW
(LONG
RADIUS)
NEW DUCT (INSIDE DIMENSIONS:
WIDTH x DEPTH)
EXISTING DUCT TO
REMAIN
FIRE
VD
DUCT WITH SOUND
LINING
FLEXIBLE DUCTWORK
(INSULATED)
MANUAL
VOLUME
EXISTING DUCT TO BE
REMOVED
SUPPLY
RETURN45°
STANDARD BRANCH SUPPLY
OR RETURN, NO SPLITTER(45° TAP)
45°
2 1
1/24
STAINLESS STEEL
AUTOMATIC CONTROL DAMPER
MODULATING
AUTOMATIC CONTROL DAMPER TWO
POSITION
FAN POWERED VARIABLE
VOLUME TERMINAL UNIT WITH HEATING COIL
MB
DOUBLE DUCT MIXING
BOX
TERMINAL UNIT WITH REHEAT
COIL
POINT OF CHANGE IN DUCT
CONSTRUCTION BY STATIC PRESSURE
CLASS. THE NUMBER ASSIGNS
PRESSURE CLASS (IN. OF WATER)
WHICH WILL ACCOMMODATE
MAXIMUM OPERATING PRESSURE IN
THE DUCT SUBSECTION. THE
SYMBOL CONTINUES THE
ASSIGNMENT UNTIL THE DUCT
TERMINATES OR ANOTHER SYMBOL
APPEARS. A "N" SUPERSCRIPT
INDICATES NEGATIVE PRESSURE.
PIPING SYMBOLS
HOT WATER HEATING SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
HOT WATER HEATING RETURN
HWS
HWR
CHR
CHS
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRICREDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
FLOW ELEMENT
PIPE UP
PIPE DOWN
MODULATING CONTROL VALVE
FE
GENERAL PIPING SYMBOLS
VALVE SYMBOLS
DRAWING SYMBOLS
BASIC MATERIALS
EXISTING TO BE REMOVED (HEAVY, DASHED LINE)
EXISTING TO REMAIN (THIN, HALFTONED LINE)
NEW (HEAVY, SOLID LINE)
26-SF 3
DETAIL NUMBER DRAWING
DRAWING NUMBER WHERE SHOWN
SECTIONLETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
SUPPLY FAN NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (SUPPLY FAN). AN "(E)" SHOWN
IN FRONT OF EQUIPMENT TAGS NOTIFIES THAT EQUIPMENT IS
H4
H7
NUMBER WHERE DRAWN
AIR DISTRIBUTION DEVICE TAG
AIRFLOW (CFM)
45145
12x6 SA
12/6 SA
12Ø SA
RECTANGULAR DUCT TAG
DUCT CLASSIFICATION (REFER TO ABBREVIATIONS)
OVAL DUCT TAG
ROUND DUCT TAG
DUCT SIZE (INCHES)
DUCT SIZE (INCHES)
DUCT DIAMETER (INCHES)
AIR TERMINAL SYMBOLS
T ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT
CONTROLS SYMBOLS
PC PRESSURE CONTROLLER. SEE SEQUENCE
OF OPERATION
TEST PLUG (PRESSURE/TEMPERATURE)
MANUAL AIR VENT
MV
QUICK-COUPLE HOSE CONNECTOR
GATE VALVE WITH 3/4" HOSE ADAPTER
WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)
BALL VALVE
POINT OF CONNECTION BETWEEN NEW AND EXISTING WORK
DEMOLITION SHEET NOTE CALLOUT
NEW CONSTRUCTION SHEET NOTE CALLOUT
FD
\m kn ot t\D
\R ev it Lo ca l F ile s\
_m t@ ab eg ro up c.
co
.rv
1:
:3
AM
MH-001
MECHANICAL LEGENDS,
SYMBOLS, NOTES, & SCHEDULES BUILDING 3126
11/27/19 KJD JARKYLE J .DAVIS, P.E.
FL License #84275
NOTES:
1. AIR DISTRIBUTION DEVICES LOCATED WITHIN ACOUSTICAL TILE CEILINGS SHALL BE
PROVIDED WITH BORDER TYPE 3 FOR LAY-IN MOUNTING. AIR DISTRIBUTION DEVICES
LOCATED WITHIN GYPSUM BOARD CEILINGS OR WALLS SHALL BE PROVIDED WITH
BORDER TYPE 1 FOR SURFACE MOUNTING. REFER TO ARCHITECTURAL DOCUMENTS
FOR CEILING TYPES.
2. AIR DISTRIBUTION DEVICES LOCATED IN SMALL ROOMS WHERE FULL 24"x24" GRID
ARE NOT AVAILABLE SHALL BE PROVIDED WITH SURFACE MOUNTING BORDERS IN
LIEU OF LAY-IN. SECURE EACH DEVICE TO CEILING GRID WITH FIELD-FABRICATED
SUPPORTS.
AIR DISTRIBUTION SCHEDULE
MARK CFM NECK SIZE
FACE SIZE
LENGTH DESCRIPTION
A 0-100 101-220
6Ø 8Ø
24X24
SUPPLY DIFFUSER
BASIS OF DESIGN: PRICE - ASPD
COLOR: OFF-WHITE
MATERIAL: ALUMINUM
OPPOSED BLADE DAMPER: NO
B 0-2245 60X16 60X16 RETURN GRILLE
BASIS OF DESIGN: PRICE - 635
COLOR: MATCH WALL
OPPOSED BLADE DAMPER: YES
C 0-175 175-375 376-550
8Ø 10Ø 16Ø
TRANSFER GRILLE
BASIS OF DESIGN: PRICE - APDDR
COLOR: OFF-WHITE
OPPOSED BLADE DAMPER: NO
GENERAL NOTES
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A FURRED CHASE OR
ABOVE THE HARD SUSPENDED CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT SIZES
ARE NET INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND INSTALLED UNDER THE
ARCHITECTURAL SPECIFICATIONS.
4. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD EQUIPMENT
DETAILS.
5. LOW WALL RETURN GRILLES CALLED OUT ON DRAWINGS ARE TO BE INSTALLED WITH BOTTOM ELEVATION OF REGISTER AT 7" [175mm] ABOVE FINISHED FLOOR.
6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS, REGISTERS, AND GRILLES.
7. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS.
TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.
8. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION.
COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN
PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR
INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST.
9. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT
CONSTRUCTION STANDARD.
10. INSTALL ALL FIRE DAMPERS, SMOKE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS IN ACCORDANCE WITH MANUFACTURE'S INSTALLATION DIRECTIONS. PROVIDE ACCESS DOORS TO ALLOW COMPLETE
INSPECTION AND MAINTENANCE OF ALL DEVICES.
11. PROVIDE 1.5R ELBOWS IN DUCTWORK AS INDICATED. IF 1.5R ELBOWS DO NOT FIT, PROVIDE 1.0R ELBOWS. IF 1.0R ELBOWS DO NOT FIT, PROVIDE 90 DEGREE RECTANGULAR DUCT ELBOWS WITH TURNING
VANES.
12. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED.
13. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING
PLANS AND EQUIPMENT OF ALL TRADES.
14. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE
FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS.
15. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE
ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.
16. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE
PAINTED FLAT BLACK.
17. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.
18. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.
19. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO
FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.
20. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND
OTHER AIR DISTRIBUTION DEVICES.
21. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO FANS, AIR HANDLING UNITS, AND FAN COIL UNITS.
22. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE
CONNECTED.
23. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS.
24. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL
FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.
25. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.
AIR HANDLING UNIT REBALANCE SCHEDULE
MARK SUPPLY CFM OUTSIDE AIR CFM
3126-(E)AHU 1 1625 390
3126-(E)AHU 2 1125 165
1. AIR HANDLING UNITS SHALL BE REBALANCED TO VALUE INDICATED ABOVE.
MINI-SPLIT DUCTLESS HEAT PUMP SCHEDULE
INDOOR UNIT OUTDOOR UNIT
MODEL NO. SA CFM (MAX.)
TOTAL COOLING
CAPACITY (MBH)
TOTAL HEATING
CAPACITY (MBH) MARK MODEL NO. SEER NOM. TONS
AMBIENT TEMP.
(°F)
UNIT ELECTRICAL
RATED AMPS MCA MOCP V/PH/HZ
LSN180HSV5 706 18.0 21.6 ODU-1 LSU180HSV5 21.5 1.5 95 9.85 13 20 208/1/60
1. MODEL NUMBERS AND UNIT SELECTIONS ARE BASED ON LG.
2. INDOOR UNIT IS ELECRICALLY POWERED FROM THE OUTDOOR UNIT.
3. PROVIDE SINGLE POINT ELECTRICAL CONNECTION.
4. DISCONNECT PROVIDED BY ELECTRICAL. REFER TO ELECTRICAL DRAWINGS.
5. PROVIDE LOW AMBIENT KIT FOR OPERATION IN AMBIENT TEMPERATURES DOWN TO 0° F.
6. SIZE REFRIGERANT LINES PER MANUFACTURER RECOMMENDATIONS. PROVIDE OVERSIZE LINES AND/OR REFRIGERATION LINE EXTENSION KIT BASED ON
MANUFACTURERS RECOMMENDATIONS FOR EXTENDED REFRIGERATION LINE RUNS.
7. PROVIDE 5 YEAR COMPRESSOR WARRANTY.
8. PROVIDE ANTI-RECYCLE COMPRESSOR TIMER.
9. PROVIDE CONDENSER COIL GUARDS.
10. PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT. UNITS SHALL BE THERMOSTATICALLY CONTROLLED TO CYCLE WITH LOADS. NO ADDITIONAL CONTROLS ARE REQUIRED.
11. PROVIDE CONDENSATE PUMP WITH INLINE CHECK VALVE LOCATED IN DRAIN LINE.
SHEET LIST
Sheet Number Sheet Name
MH-001 MECHANICAL LEGENDS, SYMBOLS, NOTES, & SCHEDULES
MD-101 MECHANICAL FLOOR PLAN - DEMO
MH-101 MECHANICAL FLOOR PLAN - NEW
MH-201 MECHANICAL DETAILS
EXHAUST FAN SCHEDULE
MARK MANUFACTURER MODEL NO. TYPE CFM STATIC PRESS. FAN RPM
ELECTRICAL
DRIVE TYPE MAX SONESFLA V/PH/HZ
3126-EF-1 BROAN XB80 CEILING CABINET 70 0.25 - 0.3 120/1/60 DIRECT 0.3
3126-EF-2 BROAN XB80 CEILING CABINET 70 0.25 - 0.3 120/1/60 DIRECT 0.3
3126-EF-3 BROAN XB80 CEILING CABINET 70 0.25 - 0.3 120/1/60 DIRECT 0.3
3126-EF-4 BROAN XB80 CEILING CABINET 70 0.25 - 0.3 120/1/60 DIRECT 0.3
1. DISCONNECT SWITCH PROVIDED BY ELECTRICAL. REFER TO ELECTRICAL DRAWINGS.
2. PROVIDE SPEED CONTROLLER.
3. ALL EXHAUST FANS TO BE INTERLOCKED W/ LOCAL LIGHTING CONTROL. REFER TO ELECTRICAL DRAWINGS.
1 1
3126-(E)CU 13126-(E)AHU 1
3MD101 2
6 5
:2
MD-101
MECHANICAL FLOOR PLAN - DEMO BUILDING 3126
1/4" = 1'-0"MD-101
1 MECHANICAL FLOOR PLAN - BLDG 3126 - DEMO
1. DEMOLISH ALL EXISTING SUPPLY AND RETURN DUCTWORK AND
SUPPLY AND RETURN CEILING DEVICES WITHIN THIS AREA.
2. EXISTING AIR HANDLING UNIT TO BE RELOCATED. ALL REFRIGERANT
AND CONDENSATE PIPING SHALL BE DEMOLISHED. PATCH
PENETRATIONS TO MATCH EXISTING WALL TYPE.
3. EXISTING OUTDOOR UNIT TO BE RELOCATED.
4. DEMOLISH OUTSIDE AIR DUCT AND LOUVER. PATCH WALL OPENING
TO MATCH EXISTING WALL TYPE.
5. EXISTING SUPPLY AIR DUCT DEMOLISHED BACK TO AIR HANDLING
UNIT.
6. EXISTING RETURN AIR DUCT DEMOLISHED BACK TO AIR HANDLING
UNIT.
DEMO GENERAL NOTES:
1. CONTRACTOR SHALL PERFORM A PRE-DEMO TEST AND BALANCE OF
EXISTING UNITS PRIOR TO DEMOLITION AND A REPORT SHALL BE
SUBMITTED TO ENGINEER FOR REVIEW.
2. RELOCATE EXISTING THERMOSTATS TO LOCATIONS SHOWN ON NEW PLAN.
3. DEMOLISH EXISTING ROOF EXHAUST FAN AND PROVIDE CAP FOR CURB.
NTSMD-101
3 M - PHOTO 2 - DEMO
2 M - PHOTO 1 - DEMO
4 M - PHOTO 3 - DEMO
5 M - PHOTO 4 - DEMO
SHELVESK-2861HUDSONC_LAVATORYCAST IRON
K-2861HUDSONC_LAVATORYCAST IRON K-2861HUDSONC_LAVATORYCAST IRON
x1
SA
RA
x8 S
10x8 SA
8ø SA
8x8 SA
T
3126-ODU 1
3126-(E)AHU 1 3126-(E)CU 1
OFFICE 100
A 90
A 85 A 150
A 175
A 175 A 175
A 135
A 140
A 220
A 215
A 50
A 215
A 175
A 50 A 50
A 200 A 200
A 200
A 50
3126-EF 1
3126-EF 2
3126-EF 3 3126-EF 4
C 150 C 150
C 175
C 175 C 425 C 425
C 425 C 425
14x8 SA
C 375
C 375
C 550C 550 C 410
C 415 C 415
14x8 SA
8ø
6ø EA 6ø EA
6ø EA
B2245 15
62x18 RA
16 161616
MH-101
3126-IDU 1
12x16 SA
8x8 OA
15 1
B2245
FLOOR
3126-(E)AHU 1
14x20 SA x2
14x20 RA
10x10 OA
15 1
B2245
:3
MECHANICAL FLOOR PLAN - NEW BUILDING 3126
1. ROUTE NEW 3/4" CONDENSATE THRU NEW WALL PENETRATION AND
DISCHARGE ON SPASHBLOCK.
2. SPLASHBLOCK.
3. RELOCATED OUTDOOR UNIT.
4. RELOCATED AIR HANDLING UNIT.
5. PROVIDE MANUAL BALANCING DAMPER AND MOTORIZED DAMPER.
MOTORIZED DAMPER SHALL BE INTERLOCKED WITH OPERATION OF
AHU. BALANCE OA TO MEET OA INDICATED IN SCHEDULE.
6. DUCT SAME SIZE AS UNIT CONNECTION.
7. MANUFACTURER'S RECOMMENDED CLEARANCE.
8. EQUIPMENT MOUNTED ON 4" CONCRETE PAD. EXTEND CONCRETE PAD
6" BEYOND PERIMETER OF EQUIPMENT.
9. 3/4" CONDENSATE ROUTED ABOVE CEILING.
10. REFRIGERANT LINES ROUTED ABOVE CEILING.
11. ROUTE CONDENSATE AND REFRIGERANT LINES THROUGH WALL AND
SEAL PENETRATION WATERTIGHT. PROVIDE METAL SHROUD TO
CONCEAL PIPING FROM PENETRATION DOWN TO GRADE. PAINT METAL
SHROUD TO MATCH EXISTING BUILDING FINISH. CONDENSATE LINE
SHALL BE ROUTED DOWN TO DISCHARGE AT SPASHBLOCK.
REFRIGERANT LINES SHALL BE ROUTED TO OUTDOOR UNIT.
12. MOUNT EXISTING CONDENSING UNIT ON 4" CONCRETE PAD. EXTEND
CONCRETE PAD 6" BEYOND PERIMETER OF EQUIPMENT.
13. 12"X12" OUTSIDE AIR LOUVER. BASIS OF DESIGN - GREENHECK
EHH-601D.
14. 18"X18" OUTSIDE AIR LOUVER. BASIS OF DESIGN - GREENHECK
EHH-601D.
15. ROUTE NEW REFRIGERANT PIPE THRU NEW WALL PENETRATION AND
AND CONNECT TO EXISTING UNIT. SIZE REFRIGERANT PIPING PER
MANUFACTURER'S INSTRUCTION.
16. ROUTE 6" EA TO WALL CAP. BASIS OF DESIGN - BROAN 843BL.
17. 3126-(E)AHU 1 EXISTING THERMOSTAT NEW LOCATION.
18. 3126-(E)AHU 2 EXISTING THERMOSTAT NEW LOCATION.
19. ANGLE IRON SUPPORT (SEE DETAIL #13, SHEET M-201).
NEW GENERAL NOTES:
1. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE
SIZE OF THE DIFFUSER NECK.
1/4" = 1'-0"MH-101
1 MECHANICAL FLOOR PLAN - BLDG 3126 - NEW
1/2" = 1'-0"MH-101
3 MECHANICAL SECTION - 3126-(E)AHU 2
1/2" = 1'-0"MH-101
2 MECHANICAL SECTION - 3126-(E)AHU 1
0 1' 2' 4' 6'
1/2" = 1'-0"
W1/2W
2/3W
VANE
R SHALL
EQUAL
OR BE
GREATER
THAN W.
OR BE
GREATER
THAN
1/3W.
OR BE
GREATER
THAN
1/6W.
1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
2. ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT
RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES
SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED
BY SMACNA.
1. ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS
DETAILED BY SMACNA.
2. WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS
VANE TYPE REGARDLESS OF W DIMENSION.
3. ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm]
TRAILING EDGE.
4. WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES
SHALL BE DOUBLE VANE TYPE.
W1
SMACNA FIGURE 4-6
45° LEED IN RIGID
DUCT TO AIR
TERMINAL UNIT.
MAIN SUPPLY
PLAN VIEW
FLOW
LO
MAIN EXHAUST OR RETURN
PLAN VIEW
AIR
FLOW AIR
FLOW
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4"
[100mm] MIN.
BRANC
H DUCT
VD
FLEXIBLE DUCT
SIZE SAME AS
DIFFUSER INLET:
5'-0" MAX LENGTH
12"
SUPPORT SADDLE
FROM STRUCTURE
VOLUME DAMPER
W/ LOCKING QUAD
SADDLE
SHEET
METAL
CONICAL OUTLET
BRANCH DUCT
USE RIGID
ELBOWS FOR
CHANGE
OF DIRECTION
GREATER
THAN 45°
[300mm]
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT
(TYP.)
NOTE:
THE USE OF FLEXIBLE AIR DUCT CONNECTORS ARE NOT
PERMITTED FOR THE DEDICATED AHU SERVING THE
SURGICAL
SUITE.
TYPICAL
DIFFUSER OR
REGISTER IN
LAY-IN CLG.
THERMAL
INSULATION
SEE SPECIFICATIONS
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
FLANGED
ON
FAN SIDE
WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6" [150mm] NOMINAL WITH
MATERIAL
TAUT
FLEXIBLE
MATERIAL
AS
SPECIFIED
1"x1/8" [25x3mm] DRAW
BAND
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
5/16" [8mm] FLANGE
SHEET METAL
SCREWS
ON 12" [300mm]
CENTERSRIVET ON
4" [100mm]
CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
1" [25mm] FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2" [40mm]
POCKET SLIP
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
[15mm] [15mm] [40mm]
1 1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6" [150mm] NOMINAL WITH MATERIAL TAUT
FLANGED
ON FAN SIDE
WASHER
FLEXIBLE
MATERIAL AS
SPECIFIED
1/2" 1 1/2"1/2"
3. INSULATION: FOR COLD DUCTS INSULATE BRACES AND PROVIDE
VAPOR BARRIER.
4. SIMILAR FOR RECTANGULAR DUCT.
MAXIMUM DUCT WIDTH
IN. [mm]
UP TO 26 [650]
27 [675] TO 40 [1000]
41 [1000] TO 60 [1500]
61 [1500] TO 72 [1800]
MAXIMUM SIZE ANGLE
NONE
1-1/2x1-1/2x3/16 [40x40x7] 2x2x3/16 [50x50x7] 2x2x3/16 [50x50x7]
MAXIMUM SPACING
GALVANIZED ANGLE
IRON OR
EQUIVALENT
STRENGTH CHANNEL
ALL THREAD
ROD. MINIMUM
3/8" [10mm]∅
72 [1800] 48 [1200] 24 [600]
1. PROVIDE BRACING TO LIMIT THE AMPLITUDE OF WALL VIBRATION AND WALL
DEFLECTION TO SPECIFIED MAXIMUMS.
2. MINIMUM BRACING REQUIREMENTS:
BAND
OVER 50"
[1250mm]∅
HANGER RODS
BAND OF
SAME SIZE AS
HANGER STRAP
LOAD RATED
FASTENERS
50" [1250mm]∅ &
UNDER
TABULATED DATA FROM SMACNA ALLOWS
FOR DUCT REINFORCING AND
INSULATION, BUT NO EXTERNAL LOAD.
2500 [1133]
1320 [598]
420 [190]ONE 1 [25] x 18 GA STRAP36 [900]
TWO 1/2 [13]∅ RODS
TWO 3/8 [10]∅. RODS
ONE 1 [25] x 16 GA STRAP
84 [2100]
60 [1500] 50 [1250] 700 [317]
ONE 1 [25] x 22 GA STRAP
QUANTITY/SIZEMAX. DUCT ∅
26 [650]
HANGER STRAPS OR RODS
MAX. LOAD
LBS. [kg]
260 [119]
MAX.
144 [3600]
SPACING
IN. [mm] IN. [mm]
VOLUME DAMPER DETAIL
1. DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR
INSULATION.
2. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION
SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS & ROUND
DAMPERS.
INSULATION SEE
SPECIFICATION
BLADE
1/8" [6mm]
CLEARANCE
ALL AROUND
OUTSIDE END
BEARING
INSIDE END
BEARING
HANDLE WITH
LOCKING
QUADRANT
STAND-OFF
1/2" [15mm]
ROUND ROD PIN
STIFFEN
BLADE AS
REQUIRED
SIDE ELEVATION SECTION
18 GAUGE STAINLESS STEEL
STRAPS 1" WIDE MIN (DO
NOT BLOCK ACCESS
PANELS) 2-MIN PER 4'0".
WRAP CONTINUOUS OVER
CONDENSER AND SECURE
TO CONCRETE PAD WITH
1/4"X1-1/2" STAINLESS
STEEL CONCRETE SCREWS
OR ANCHORS. (EACH SIDE)
4" THK
FIBERMESH
REINFORCED
CONCRETE PAD
6" MIN
ALL
SIDES
CONDENSING UNIT
PROVIDE 6" CLEAR
GRAVEL AROUND
CONDENSER. SOD
THEREAFTER.
3/8" STEEL ROD
W/ THREADED ENDS
(TYP. 4 PLCS.)
REFRIGERANT PIPING
SUSPENDED RODS
FROM CONCRETE
FLOOR SLAB
EQUIVALENT TO
SIMPSON BLUE
BANGAR CAST IN
PLACE ROD HANGARS
SUPPORT
FROM
STRUCTURE
ABOVE AS
REQUIRED
VIBRATION
ISOLATORS
CONDENSATE
LINE
INDOOR UNIT
CASSETTE
LINTEL BY OTHERS
CLIP ANGLE
(ALL AROUND)
BIRDSCREEN FRAME
WITH MAXIMUM FREE
AREA
BIRDSCREEN
STORMPROOF LOUVER
CAULKING
15°
PITCH TO DRAIN
SECURE FRAME TO
WALL WITH EXPANSION
BOLTS 12" ON CENTER,
ALL 4 SIDES
SHEET METAL FASTENED TO ANGLE
6" ON CENTER. ANGLE FASTENED
TO LOUVER AT INTERMEDIATE
SUPPORTS AND FRAMES
FASTEN 6" ON CENTER
WALL BY OTHERS
RAIN SILL
CAULK
EXTERIOR
CAULK ALL
AROUND
NOTE: SUPPORT PLENUM FROM FLOOR
OR STRUCTURE ABOVE WITH GALVANIZED
STEEL ANGLES AND CHANNELS
SUPPLY
RETURN
OUTSIDE AIR
MOTORIZED DAMPER
INTERLOCKED WITH
FAN MOTOR
NEW VOLUME DAMPER
NEW R/A DUCT, DUCTED TO AHU
UNISTRUT P2481 PIPE BRACKET
ANCHOR UNISTRUT SUPPORT TO
NEW CONDENSATE
DRAIN (INSULATED)
REFRIGERANT
LINES
FLEX CONNECTION
NOTE: AN OVERFLOW DEVICE SHALL BE PROVIDED FOR
CONDENSATE CONTROL IN ACCORDANCE TO FBC - MECHANICAL
(2017) 307.2.3 IF SOME FORM OF AUXILLIARY/SECONDARY DRAIN
SYSTEM IS NOT CURRENTLY INSTALLED.
EXISTING AIR
HANDLING UNIT
NEW DUCT SUPPORT ANCHOR TO
SLAB
FLOOR SLAB
NEW VOLUME DAMPER
MOUNT UNIT ON ANGLE IRON
SUPPORT. HEIGHT OF SUPPORT
SHALL BE DETERMINED BASED
ON RA DUCT CONNECTION
MH-201
MECHANICAL DETAILS BUILDING 3126
DUCTWORK RADIUS ELBOWS2
DUCTWORK SQUARE VANE ELBOWS3
SUPPLY DUCT TAKEOFF - AIR TERMINAL UNITS4
EXHAUST OR RETURN BRANCH DUCTWORK5
FLEXIBLE AIR DUCT CONNECTOR6
FLEXIBLE DUCT CONNECTIONS7
FLAT OVAL/RECTANGULAR DUCT HANGERS/ REINFORCEMENT9
ROUND DUCT HANGERS8 N.T.S.
VOLUME DAMPER DETAIL1
CU MOUNTED ON GRADE10
SUSPENDED MINISPLIT CEILING CASSETTE11
WALL LOUVER/PLENUM12
VERTICAL AHU INSTALLATION13
GENERAL NOTES
1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS.
2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL CURRENT STATE AND LOCAL CODES.
3. COORDINATE UTILITIES AND SERVICES WITH CIVIL ENGINEER.
4. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TO INDICATE EXACT
ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS AND OTHER POTENTIAL
OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES.
5. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES.
6. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL ROOMS OR AS SPECIFICALLY
NOTED.
7. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS.
8. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS WITH U/L LISTED
ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE
ARCHITECTURAL DRAWINGS FOR FINAL FINISHES.
9. FLASH AND COUNTER-FLASH ROOF PENETRATIONS.
10. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH ALL TRADES, THE ARCHITECT AND
THE STRUCTURAL ENGINEER.
11. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE BETWEEN SLEEVE INSIDE SURFACE
AND PIPE EXTERIOR.
12. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
13. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN & FLOOR SINK TRAP SEALS.
14. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, DEVICES, APPLIANCES AND APPARATUS.
15. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED.
16. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL SATE AND LOCAL CODES. INSTALL CLEAN OUT WITH COVER FLUSH TO
FINISH SURFACE.
17. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO
NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS
SHALL BE RE-ROUTED AT NO ADDITIONAL COST.
18. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH-IN AND MAKE FINAL CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS CONTRACTOR OR FURNISHED BY OTHERS.
19. PROVIDE WATER HAMMER ARRESTOR ON H & CW PIPE.
20. CONTRACTOR TO PROVIDE ALL APPURTENANCES TO COMPLETE INSTALLATION AND CONNECTIONS IN ITS ENTIRETY TO
FIXTURES AND EQUIPMENT.
DIRECTION OF FLOW
SIDE CONNECTION
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
AND EXISTING WORK
POINT OF CONNECTION BETWEEN NEW
PIPE UP
PIPE DOWN
DOMESTIC HOT WATER, HOT WATER
DOMESTIC COLD WATER, COLD WATER
DOMESTIC HOW WATER RETURN, HOT WATER RETURN
VENT (SANITARY)
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
DRAWING NUMBER WHERE DRAWN
PL105
PL105
PIPING SYMBOLS
EXISTING DOMESTIC HOT WATER, HOT WATER (HALFTONED)
EXISTING DOMESTIC COLD WATER, COLD WATER (HALFTONED)
EXISTING DOMESTIC HOW WATER RETURN, HOT WATER RETURN (HALFTONED)
SOIL, WASTE, OR SANITARY SEWER
EXISTING VENT (SANITARY) (HALFTONED
SS S
EXISTING SOIL, WASTE, OR SANITARY SEWER (HALFTONED)SS S
ABOVE GRADE PIPING (EXCEPT FOR VENT)
BELOW GRADE PIPING
GENERAL SYMBOLS
VALVE SYMBOLS
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG
(PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENT
AV
TYPICAL UNIT NO.
BUILDING NO.