This document is an Attachment C for an emergency fire precautions agreement for the Angeles National Forest, specifically for contract number 127EAT25S0000. The attachment outlines detailed fire safety protocols for contractors operating mechanical equipment during elevated fire risk conditions (Activity Levels C and D), requiring specific emergency preparedness measures such as installing a fire weather station, maintaining hourly/half-hourly fire inspections, and providing fire patrol personnel with specialized equipment like backpack pumps, fire extinguishers, and portable water tank supplies.

For Activity Level C (after 1:00 p.m.), contractors must have a fire patrol person with a 5-gallon backpack pump, conduct hourly re-inspections of treated areas, and ensure mechanized equipment has self-actuated fire extinguishing systems and fire extinguishers. For Activity Level D (between 8:00 a.m. and 1:00 p.m.), similar but more stringent requirements apply, including half-hourly inspections, additional water tank supply, and the potential availability of a crawler tractor with a dozer blade to construct fire trails. The Forest Service reserves the right to suspend or terminate the agreement if these requirements are not met.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT C FY25 SIERRA PELONA LANDSCAPE

INTEGRATED FUELS

Additional Emergency Fire Precautions

For

Angeles National Forest Construction and Service Contracts

Contract Number 127EAT25S0000

This agreement is between . hereafter referred to as Contractor, and the USDA Forest Service, acting through the Contracting Officer, from the Angeles National Forest, hereafter referred to as Forest Service.

In accordance with the contract Fire Plan for the subject contract, Forest Service and contractor agree to the following:

In lieu of prohibiting certain operations during Project Activity Levels C and D, as required in The Contract Fire Plan, Contracting Officer agrees that Contractor may be allowed to operate subject to taking Additional Emergency Fire Precautions.

To be considered for the Additional Fire Precautions the Contractor must install a fire weather station in the contract area for obtaining Activity level records. The Forest Service shall designate the fire weather station location. Instruments needed to obtain Activity level shall meet specifications and standards in “Fire Weather Observers handbook” which is available for inspection in the District Ranger’s Office. When activity level C or above is reached, observations shall be made at 2-hour intervals, beginning not later than an hour designated by the COR. Emergency precautions for the measured Activity level shall be implemented. Records of weather measurements shall be maintained and shall be available to the Forest Service.

Level C:

For all mechanical equipment operated after 1:00 p.m. Contractor shall furnish:

1. Provide a Fire Patrol person with a 5 gallon backpack pump.

2. Fire Patrolperson at a safe distance behind each piece of equipment or patrolling with chainsaw operators.

3. Hourly re-inspection of that day’s previously treated areas.

4. For mechanized equipment or chippers charged, on-board self actuated fire extinguishing system for each piece of subject equipment and one 10 pound 4A-60B:C fire extinguisher or equivalent, or two 10 pond 4A-60B:C fire extinguishers or equivalent on board.

5. Immediately available on contract area:

a. Portable water tank supply that meets Fire Plan specifications and capable of providing tank mixed foam approved by the Forest Service – Tank Truck requirements and is ready for immediate use. Tank supply must be either self-propelled or able to be towed by a rubber-tired skidder or crawler tractor.

Level D:

For all mechanical equipment operated between 8:00 a.m. and 1:00 p.m. no operations will be permitted after 1:00 p.m. Contractor shall furnish:

1. Provide a Fire Patrolperson with 5 gallon back pack pump.

2. Fire Patrolperson at each piece of equipment or patrolling with chainsaw operators.

3. Half-hourly re-inspection of that day’s previously treated areas.

4. For mechanized equipment or chippers charged, on-board self-actuated fire extinguishing system for each piece of subject equipment and one 10 pound 4A-60B:C fire extinguisher or equivalent, or two 10 pound 4A-60B:C fire extinguisher or equivalent on board.

4. Immediately available: (

a. Portable water tank supply that meets Fire Plan specifications – Tank Truck requirements and is ready for immediate use. Tank supply must be either self-propelled or able to be towed by a rubber-tired skidder or crawler tractor, operated by a Fire Patrolperson in communication with subject equipment and other Fire Patrolpersons on patrol and contract personnel. This water tank supply is in addition to that already required for level C.

c. Crawler tractor with dozer blade to construct fire trail.

If the Forest Service determines that the above requirements are not met, this agreement may be suspended or terminated by the Forest Service.