This document includes building plans and specifications for an Army dining facility at Fort Sill, Oklahoma, as well as details for a related full food services solicitation. The plans provide dimensions and notes for the proposed DFAC 3720, outlining space allocations and requirements for a 1,281 square foot kitchen, 489 square foot dishwashing area, and over 49,000 square feet of combined building space and canopies to accommodate between 1,300 to 2,600 personnel. The solicitation seeks full food services support at Fort Sill under solicitation number W5168W23R0007, issued by the Department of the Army. Responses are due based on the standard solicitation timeline. The contractor will be expected to provide all staff, equipment, and supplies necessary to serve meals in the new dining facility once constructed.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DFAC 2755
NOTE #1
THE KITCHEN EQUIPMENT CONTRACTOR WILL NOT
BE RESPONSIBLE TO FURNISH LINE OR DISCONNECT
SWITCHES, SAFEIY CUT-OUTS, CONTROL PANELS,
FUSE BOXES, FITTINGS, CONNECTIONS OR WIRING,
EXCEPT WHEN SPECIFIED TO DO SO UNDER
GENERAL KITCHEN EQUIPMENT SPECIFICATIONS.
NOTE #2
WE RESERVE THE RIGHT TO INSPECT &
CORRECT ANY ALLEGED DEFICIENCIES. NO BACK-
CHARGES WILL BE HONORED UNLESS AUTHORIZED
BY GREAT LAKES HOTEL SUPPLY COMPANY.
NOTE #3
ALL CONNECTIONS ARE SHOWN AT THE ACTUAL
LOCATION WHERE THE STUB-UP SHOULD TERMINATE
THRU THE WALL OR FLOOR, SO rr CAN BE BRANCHED
TO THE CONNECTION PDINT ON THE FIXTURE AT TIME
OF FINAL HOOK-UP. ALL FINAL HOOK-UPS ARE BY
MECHANICAL, ELECTRICAL OR VENTllATING CONTRACTORS.
NOTE #4
MECHANICAL, ELECTRICAL & VENTILATING CONTRACTORS
SHOULD ROUGH-IN ALL FOOD SERVICE EQUIPMENT
FROM THESE DIMENSIONED DRAWINGS. ANY DEVIATION
FROM THESE PLANS ARE NOT OUR RESPONSIBILITY.
NOTE #5
GREAT IAKES HOTEL SUPPLY COMPANY TO BE RESPONSIBLE
ONLY FOR CONNECTIONS REQUIRED FOR EQUIPMENT BEING
FURNISHED BY GREAT LAKES HOTEL SUPPLY CO. ALL
OTHER REQUIREMENTS TO BE VERIFIED BY ARCHlrECT, OWNER OR VENDOR/SUPPLIER. ANY ADDITIONAL WIRING, ELECTRICAL OUTLETS, PIPING, FLOOR DRAINS, ETC., TO BE
LOCATED BY ARCHlrECT, OWNER OR VENDOR/SUPPLIER.
NOTE #6
SPEcw_ NOlE TO GENERAL CONTRACTOR AND/OR SUBCONTRACTOR
FOR QUARRY TILE OR CONCREIE WEARING FLOORS: THE SHEET
METAL PANEL FACINGS MAY BE SUSCEPTIBLE TO STAINING DUE TO
EXCESSM: MOISTURE CR£AlED BY HYOOATION OF CONCREIE lYPE �TERIAI.S. lHEREFORE IT IS ABSOLl/lEI.Y NECES51RY THAT £ACH m BE PROPERLY IDllllAlED. N.SO TAKE NOTE THAT SPEcw_ PRECMITIONS
MUST BE TAKEN WHEN USING MUR�TIC ACID DUE TO EFFECTS
IMlROCHLORIC ACID FUMES fJ.l.'IE ON ALUMINLlt & STAINLESS STEEL f ' ' I I I
I I I I I I
__ I ______ I ______________ I ___________ _ I
I I
I I
I I
I I f I
I I it
I I
I I I I
-·�·-----������o��o�-�o�o�o��rn���Ft.�������ift���F=5I����� I r I
I I
I I
I I
I
I
- - _J +-- --•---
I
I I
I I
I I
I I
I I
I I
I I
I
I I
I
I I
I I I
I I I I I I
EQUIPMENT lAYOUT
GYB JOB NO. SCALE
1------,1----------+-�;....;..;.._+--=-"--'-'-...;...._-------,f'.-'ESW ---I 0B.B-1 1/B'=l'-0'
ESW
12-22-08 MISC, REVISIONS
12-12-08 BOOSTER ADDED
12-11-08 RE-SCALE DRAWINGS
DRAWN BY
12-02-08 NEW BACKGROUND E-.S.W.
11-18-08 DIMENSIONS ADDED
J-10-09 SERVERY REVISIONS 11-06-08 PROPOSED SERI/ERV REVISION
DATE
DATE REVISION BY DATE REI/ISION ()q-03-(}6
Cf>
I
I I
I
I I
GREAT lAKES HOTEL SUPPLY CO.
FOOD SERVICE EQUIPMENT and SUPPLIES
1961 GRAND RIVER AVE. DEmOIT, MICHIGAN 48226
313.962.9176
FAX 313.962.1317
ISO 9000 REGISTERED
Cf I
I I
I
I I
I I
I I
I ----iVr----.
lAI I
I
I
I I I
I
Q) �
PROJECT SE�ES
ENLISTED PERSONNEL'"::
0r 9
DINING FACILITY
K-2FORT SILL, OK
DFAC 3720
PLATOON
PLATOONPLATOON
PLATOON
PLATOONPLATOON
PLATOON PLATOON
OVERALL FLOOR PLAN
SCALE:
60’30’20’5’
1/16" = 1’-0" 0 10’
D
IN
IN
G
F A
C
IL
IT
Y
O V
E R
A L
L F
L O
O R
P L
A N
CANOPY NOTES
30 GALLON TRASH CONTAINERS.
1/2 WALL W/ STAINLESS STEEL COVER.
NOT USED.
DINING AREA "B", 20 TABLES = 272 SEATS.
DINING AREA "A", 20 TABLES = 272 SEATS.
DOCK LEVELER.
MENU BOARD.
HANDWASH.
NOTES
AT 50%%% SCOPE
VESTIBULE (10)
GROSS AREA COMPUTATIONS
LOADING DOCK
BUILDING
CANOPIES @ 100%%%
SPACE
BREAD STORAGE
DRY STORAGE
PAPER STORAGE
CORRIDORS
OFFICES
NET AREA COMPUTATIONS
JANITOR
RECEIVING VESTIBULE
DISHWASHING
SPACE
KITCHEN
DINING
OPTIONAL STAND-UP DINING COUNTER.9
1300-2600 PERSON
FT
4,813
17,610
6,381
2,264
1,188
1,186
2,179
1,109
1,281
FT
49,050
12,780
55,988
1300-2600 PERSON
4" CURB.10
TOTAL WITH CANOPIES
TOTAL 62,378
1. THE FOOTPRINT OF THE DINING FACILITY ENTRANCE CANOPIES AND
CANOPIES FOR THE EXTERNAL ENTRANCES TO THE PUBLIC TOILET
ROOMS CAN BE MODIFIED WITHIN THE FOLLOWING GUIDELINES.
2. MINIMUM COVER MUST BE PROVIDED TO ACCOMMODATE ONE FULL
COMPANY (FOUR PLATOONS- 240 TRAINEES) AT EACH MAIN
ENTRANCE TO THE FACILITY WITH PROPER CIRCULATION FOR DRILL
INSTRUCTORS, ETC. TOTAL CANOPY AREA CANNOT EXCEED THE
TOTAL COMBINED AREA PERMITTED BY THE STANDARD (386).
MEN/WOMEN
MEN/WOMEN/
REFRIG./FREEZER
FIELD FEEDING
LOCKER ROOM
98STORAGE
QUEUING
CAN WASH
MECHANICAL ROOM
ELECTRICAL ROOM
COMM. ROOM
2,216
REMOTE SODA (2)
1,796
SERVERY/SELF SERVICE AREA
A
B
C
D
1 2 3 4 5
Norfolk District
US Army Corps of Engineers
OFSHEET
C O
R P
S O
F E
N G
IN
E
E R
S
N O
R F
O L
K
V
IR
G
IN
IA
N O
R F
O L
K D
IS
R
T
IC
T
P lo t s c a le
J U
L Y
N O
R F
O L
K D
IS
T
R
IC
T F
IL
E
N O
S P
E C
IF
IC
A T
IO
N
N O
D R
A W
N
L a s t w o r k e d o n
F il e n a m e
P R
O J E
C T
N O
D R
A W
IN
G
N O
D E
S
IG
N E
D
C H
E C
K E
D
S U
B M
IT
T
E D
A S
S H
O W
N
D A
T E
S C
A L
E
:1
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y A
P P
1 2 3 4 5
A
B
C
D
SHEET
REFERENCE
NUMBER
C E
N T
E R
O F
S T
A N
D A
R D
IZ
A
T
IO
N
N A
O
P R
O T
O T
Y P
E D
E S
IG
N
S O
L D
IE
R
D
IN
IN
G
F A
C
IL
IT
Y
S
IN
G L
E S
T O
R Y
DFAC 5965 & 5966
DFAC 3443
| DFAC 2755 |
| Created with MetaPrint |
| 025-A101 |
| DFAC 3720 |
| DFAC 5965 5966 |
| DFAC 3343 |