ATTACHMENT B - Q58DCSRestoration_DWGs_Final.pdf
PDF 725 KB Posted
- Attached to
- NSN, Q-58 DCS Restoration
- Solicitation number
- N4008526R0105
About this file
This document is a structural design drawing set for the Q-58 Data Concentrator Shed Restoration project located at Naval Station Norfolk, Virginia, prepared by Naval Facilities Engineering Systems Command Mid-Atlantic. The project is dated 01/30/2026 and includes comprehensive architectural and engineering plans for restoration work on an existing offshore data concentrator structure.
The scope of work encompasses cleaning and recoating four 18-inch diameter battered steel pipe piles, two 15-foot W-section pile cap beams, and eight W-section upper and lower steel beams with their connections. Additional work includes cleaning and recoating four 30-inch diameter steel conduits, demolishing and replacing the existing steel ladder with a code-compliant ladder featuring a fall arrest system and swing gate access, and removing and providing new 4-inch diameter steel bollards on the docking platform. For the docking platform and fender frame system, the contractor must demolish existing foam-filled fenders, clean and verify existing C12 steel channel supports, and provide new beams, channels, angles, grating, and four foam rubrail wing-type fenders. The design adheres to ASCE 7-22, International Building Code 2024, UFC 1-200-01, UFC 3-301-01, and SDI SD-2022 standards, with specific design loads including 150 PSF for metal deck, 36 PSF ground snow load, and basic wind speeds of 118 MPH ultimate and 92 MPH nominal. All structural steel must conform to AISC specifications, with materials including ASTM A992 Grade 50 for W-shapes and A53 Grade B for pipes, stainless steel Grade 316 components for maritime environment durability, and AWS D1.1 welding standards using E70XX electrodes.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WILLOUGHBY BAY
NAVAL SUPPORT
ACTIVITY
U.S. NAVAL STATION NORFOLK
NORFOLK
U.S. NAVAL
AIR STATION
CHESAPEAKE BAY
LITTLE CREEK
U.S. NAVAL
AMPHIBIOUS BASE
VA BEACH
OCEANA
NAVAL AIR
STATION
CHESAPEAKE
SOUTHERN BRANCH
EASTERN BRANCH
ST. JULIEN'S CREEK
U.S. NAVAL ANNEX
ELIZABETH RIVER
58 460
PORTSMOUTH
U.S. ARMY CRANEY
ISLAND DISPOSAL AREA
NANSEMOND RIVER
WESTERN BRANCH
CRANEY
ISLAND NAVY
DEPOT
PROJECT SITE
NORTH PIER 14
PIER 12
PIER 11
Q-72
Q-50
Q-33
X-218 X-275 A-80
A-81
Q-88
LF-18
MASSEY HUGES DR
DE
CA
TU
R
AV
E MASSEY HUGES DR
MA
RY
LA
ND
A
VE
LAG MARINA
WILLOUGHBY SPIT
HRBT SOUTH ISLAND
INTERSTATE 64
WILLOUGHBY BAY
WILLOUGHBY BAY
Q-58
PROJECT SITE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C N
AV
AL
S
TA
TI
O
N
N O
R
FO
LK
, V
A
AS NOTED
G-001
Q -5
D
A
TA
C O
N C
E N
TR
A
TO
R
S H
E D
R E
S
TO
R A
TI
O
N
CO
VE
R
SH
EE
T
DSG
12,937,903
ADB ADB
01/28/2026
COMMANDER, NAVY INSTILLATIONS COMMAND
DEAN S. GREGORY, P.E.
1673784
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
JOHN C. MILLER, P.E.
JAMES M. SMITH, R.A.
N/A
M
ID
LA
N
T R
O
IC
C N
O R
FO
LK
NAVAL STATION - NORFOLK, VIRGINIA
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
MID-ATLANTIC
ROICC NORFOLK
FACILITIES ENGINEERING AND ACQUISITION DIVISION
NORFOLK, VIRGINIA
01/30/2026
Q-58 DATA CONCENTRATOR SHED
RESTORATION
NOT TO SCALE
VICINITY MAP
NOT TO SCALE
LOCATION MAP
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
W12X26
W12X26
TO X' - X"
FRAMING SIZE
EXISTING FRAMING SIZE
X
TOP OF
COLUMN GRID MARK
KEY NOTE
TOS X' - X" TOP OF STEEL
X" TOP OF SLAB
SPOT ELEVATION
WORKING POINT
SHEET INDEX
SHEET NO.
NAVFAC DWG. NO. SHEET TITLENO. SHEET
1 G-001 12,937,903 COVER SHEET
2 S-001 12,937,904 STRUCTURAL SYMBOLS, LEGENDS,ABBREVIATIONS, AND NOTES
3 S-101 12,937,905 DOCKING PLATFORM
4 S-102 12,937,906 CANNISTER IMPROVEMENTS
5 S-301 12,937,907 SOUTH ELEVATION
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C N
AV
AL
S
TA
TI
O
N
N O
R
FO
LK
, V
A
AS NOTED
S-001
Q -5
D
A
TA
C O
N C
E N
TR
A
TO
R
S H
E D
R E
S
TO
R A
TI
O
N
ST
RU
CT
UR
AL
S
YM
BO
LS
, L
EG
EN
DS
,A
BB
RE
VI
AT
IO
NS
, A
ND
N O
TE
S
DSG
12,937,904
ADB ADB
01/28/2026
COMMANDER, NAVY INSTILLATIONS COMMAND
DEAN S. GREGORY, P.E.
1673784
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
JOHN C. MILLER, P.E.
JAMES M. SMITH, R.A.
N/A
M
ID
LA
N
T R
O
IC
C N
O R
FO
LK
GENERAL STRUCTURAL NOTES
1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
EXECUTABLE SCOPE OF WORK ASSOCIATED WITH THIS PROJECT. THE
CONTRACTOR MUST VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO
SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND ADDITIONAL
ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK.
2. STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE. THE
CONTRACTOR MUST PROVIDE THE TEMPORARY SHORING, BRACING, GUYING,
AND SUPPORTS REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER
ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL BRACING ARE IN
PLACE. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY, AND INSPECTION OF
ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
3. THE CONTRACTOR MUST FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND
OTHER REQUIREMENTS NECESSARY FOR THE PROPER CONSTRUCTION AND
ALIGNMENT OF THE NEW PORTIONS OF THE STRUCTURE TO THE EXISTING.
THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR
FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER
PRIOR TO ORDERING MATERIALS OR BEGINNING WORK (CONSTRUCTION OR
DEMOLITION).
4. LOCATE AND PROTECT ALL EXISTING UTILITIES NEAR WHERE WORK WILL TAKE
PLACE ON THE STRUCTURE.
5. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH SAFETY
PRECAUTIONS AND REGULATIONS DURING THE WORK. THE STRUCTURAL
ENGINEER WILL NOT ADVISE ON, NOR ISSUE DIRECTION AS TO SAFETY
PRECAUTIONS AND PROGRAMS.
6. ALL ITEMS NOTED TO BE DEMOLISHED OR REMOVED WILL BECOME THE
CONTRACTOR'S PROPERTY, UNLESS NOTED OTHERWISE. DISPOSITION OF
THE ITEMS AND MATERIALS IS THE RESPONSIBILITY OF THE CONTRACTOR
AND MUST ADHERE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL
REGULATIONS.
7. THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR THE MEANS, METHODS,
TECHNIQUES, OR SEQUENCES OF PROCEDURES TO PERFORM THE WORK.
SUPERVISION OF WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, USE SIMILAR DETAILS OF
CONSTRUCTION, SUBJECT TO APPROVAL BY THE CONTRACTING OFFICER.
9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO
BE FIELD ERECTED MUST BE SUPERVISED BY THE SUPPLIER DURING
MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN
ACCORDANCE WITH THE SUPPLIER'S INSTRUCTIONS AND REQUIREMENTS.
10. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF THESE
STANDARDS, UNLESS OTHERWISE NOTED.
11. SHOP DRAWINGS AND OTHER ITEMS MUST BE SUBMITTED FOR REVIEW BY THE
GENERAL CONTRACTOR PRIOR TO FABRICATION. ALL SHOP DRAWINGS MUST
BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL. THE
REVIEW IS TO BE FOR CONFORMANCE WITH THE DESIGN CONCEPT AND
GENERAL COMPLIANCE WITH THE RELEVANT CONTRACT DOCUMENTS. THE
REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY
TO REVIEW, CHECK, AND COORDINATE THE SHOP DRAWINGS PRIOR TO
SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS
AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS
THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC. ANY PROPOSED
CHANGES MUST BE SUBMITTED IN AN RFI TO THE CONTRACTING OFFICER FOR
APPROVAL.
12. IN NO CASE MAY THE REPRODUCTION OF THE CONTRACT DRAWINGS BE USED
AS SHOP DRAWINGS. SUBCONTRACTOR/FABRICATOR MUST PROVIDE
INDEPENDENTLY CREATED DRAWINGS BASED ON THE PLANS AND DETAILS.
13. IN ACCORDANCE WITH THE IBC, SPECIAL INSPECTIONS WILL BE REQUIRED FOR
THIS PROJECT. SPECIAL INSPECTIONS MUST BE PERFORMED IN ACCORDANCE
WITH THE "SCHEDULE OF SPECIAL INSPECTIONS." THE CONTRACTOR MUST
NOTIFY THE SPECIAL INSPECTOR AT LEAST 48 HOURS IN ADVANCE FOR WORK
THAT WILL REQUIRE INSPECTION OR TESTING.
14. TAKE CARE NOT TO DAMAGE THE EXISTING STRUCTURE. WHERE EXISTING
CONSTRUCTION IS DAMAGED BY THE CONSTRUCTION REQUIRED BY THESE
DOCUMENTS, REPAIR THE DAMAGED ITEM(S) WITH MATERIALS TO MATCH THE
ADJACENT MATERIAL, TEXTURE, AND COLOR.
15. DO NOT HANG ITEMS FROM THE EXISTING STRUCTURE, UNLESS OTHERWISE
NOTED.
GENERAL STRUCTURAL SCOPE OF WORK
1. GENERAL SCOPE OF WORK INCLUDES, BUT IS NOT LIMITED TO:
Q-58 DATA CONCENTRATOR SHED
- CLEAN AND REMOVE DEBRIS FROM (4) 18" DIAMETER BATTERED STEEL PIPE
PILES COMPLETE AND RECOAT WITH COMMERCIAL GRADE PAINT.
- CLEAN AND REMOVE DEBRIS FROM (2) 15' LONG W-SECTION PILE CAP BEAMS
ALONG WITH SUBSEQUENT CONNECTIONS COMPLETE AND RECOAT WITH
COMMERCIAL GRADE PAINT.
- CLEAN AND REMOVE DEBRIS FROM (8) W-SECTION UPPER AND LOWER STEEL
BEAMS ALONG WITH SUBSEQUENT CONNECTIONS COMPLETE AND RECOAT
WITH COMMERCIAL GRADE PAINT.
- CLEAN AND REMOVE DEBRIS FROM (4) 30" DIAMETER STEEL CONDUITS
COMPLETE AND RECOAT WITH COMMERCIAL GRADE PAINT.
- DEMOLISH EXISTING STEEL LADDER AND ASSOCIATED HARDWARE COMPLETE
AND PROVIDE CODE COMPLIANT LADDER WITH FALL ARREST SYSTEM AND
SWING GATE ACCESS.
- DEMOLISH AND REMOVE (2) EXISTING 4" DIAMETER BOLLARDS COMPLETE.
- PROVIDE (2) 4" DIAMETER STEEL BOLLARDS ON DOCKING PLATFORM AS
OUTLINED IN THIS DRAWING SET.
DOCKING PLATFORM AND FENDER FRAME SYSTEM:
- DEMOLISH EXISTING FOAM FILLED FENDERS AND ATTACHMENT
HARDWARE.
- CLEAN EXISTING C12 STEEL CHANNELS PREVIOUSLY USED AS FENDER
SUPPORTS.
- VERIFY EXISTING C12 STEEL CHANNELS CONTAIN ENOUGH SECTION
MODULUS TO ATTACH EXTENDED FENDER-LANDING SYSTEM.
- RECOAT EXISTING C12 STEEL CHANNELS WITH COMMERCIAL GRADE
PAINT PREVIOUSLY USED AS FENDER SUPPORTS.
- PROVIDE BEAMS, CHANNELS, ANGLES AND GRATING FOR EXTENDED
FENDER-LANDING SYSTEM AS OUTLINED IN THIS DRAWING SET.
- PROVIDE (4) FOAM RUBRAIL WING-TYPE FENDERS PER MANUFACTURERS
RECOMMENDATIONS.
NOTE:
THE GENERAL STRUCTURAL SCOPE OF WORK DESCRIBED HEREIN IS NOT ALL
INCLUSIVE OF EVERY SINGLE ITEM OF WORK REQUIRED FOR THIS PROJECT.
REFER TO THE EXECUTABLE SCOPE OF WORK, DESIGN DRAWING SET, AND THE
BID PACKAGE DOCUMENTS FOR A COMPLETE OUTLINE OF WORK REQUIRED.
DESIGN CRITERIA NOTES
1. THE STRUCTURAL WORK TO BE PERFORMED UNDER THIS CONTRACT HAS
BEEN DESIGNED TO THE APPLICABLE DESIGN STANDARD AND / OR CRITERIA OF
THE FOLLOWING, UNLESS NOTED OTHERWISE:
A. ASCE 7-22, "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES"
B. INTERNATIONAL BUILDING CODE 2024
C. INTERNATIONAL EXISTING BUILDING CODE 2024
D. UFC 1-200-01 (01 SEPTEMBER 2022, CH 4 17 DECEMBER 2024), "DOD BUILDING
CODE"
E. UFC 3-301-01 (11 APRIL 2023, CH 4 3 JUNE 2025), "STRUCTURAL ENGINEERING"
F. SDI SD-2022, " STEEL DECK INSTITUTE STANDARD FOR STEEL DECK"
G. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF
THESE STANDARDS AT THE CONTRACT AWARD.
2. LIVE LOADS USED IN THE DESIGN OF THESE STRUCTURES ARE AS FOLLOWS:
- HANDRAIL SYSTEM(*)
- CONCENTRATED LOAD = 200 LBS
- DISTRIBUTED LOAD = 50 PLF
(*) DESIGNED FOR LOAD APPLIED IN ANY DIRECTION ALONG THE TOP
RAIL (PER IBC, LOADS ANALYZED INDEPENDENTLY)
- METAL DECK = 150 PSF
3. DESIGN LOAD CRITERIA, DETERMINED IN ACCORDANCE WITH UFC 3-301-01, IS
AS FOLLOWS:
A. BUILDING CRITERIA: RISK CATEGORY = II (ASSUMED)
B. SNOW LOADS:
- GROUND SNOW LOAD = 36 PSF
C. WIND LOADS
- BASIC WIND SPEED, V (ULTIMATE) = 118 MPH
- BASIC WIND SPEED, V (NOMINAL) = 92 MPH
- EXPOSURE CATEGORY = D
STRUCTURAL STEEL NOTES
1. ALL STRUCTURAL STEEL MUST CONFORM TO THE SIXTEENTH EDITION OF THE
ALLOWABLE STRESS DESIGN "STEEL CONSTRUCTION MANUAL" OF THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC).
2. UNLESS OTHERWISE NOTED, ALL MATERIALS MUST BE IN ACCORDANCE WITH
THE FOLLOWING ASTM SPECIFICATIONS:
MEMBER, ALL GALVANIZED ASTM MIN. STRENGTH
W-SHAPES A992 (GRADE 50) / A572 Fy = 50 KSI OTHER ROLLED/PLATE SHAPES A36 Fy = 36 KSI PIPES A53 (GRADE B) Fy = 46 KSI
STAINLESS STEEL (SS) MEMBER ASTM MIN. STRENGTH
SS BOLTS F593 (TYPE 316) Fu = 60 KSI
SS NUTS F594 (TYPE 316)
SS WASHER ANSI B18.22.1 (TYPE A PLAIN)
3. WELDS MUST BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING
CODE - STEEL" AND USE E70XX ELECTRODES. UNLESS OTHERWISE NOTED,
PROVIDE FILLET WELDS WITH MINIMUM SIZE REQUIRED BY TABLE J2.4 OF THE
"MANUAL OF STEEL CONSTRUCTION, LOAD RESISTANCE FACTOR DESIGN."
ENSURE BASE MATERIAL IS SUFFICIENTLY CLEAN TO PERMIT WELDS TO BE
MADE THAT MEET QUALITY REQUIREMENTS OF AWS D1.1. ALL FILLER MATERIAL
MUST HAVE A MINIMUM YIELD STRENGTH OF 58 KSI.
4. PRIOR TO WELDING, THE CONTRACTOR MUST SUBMIT CERTIFICATION FOR
EACH WELDER STATING THE TYPE OF WELDING AND POSITIONS QUALIFIED
FOR, THE CODE AND PROCEDURE QUALIFIED UNDER, DATE QUALIFIED, AND
THE FIRM AND INDIVIDUAL CERTIFYING THE QUALIFICATION TESTS.
5. HOLES IN STEEL MUST BE DRILLED OR PUNCHED. BURNING OF HOLES IS
PROHIBITED.
6. SPLICING OF STEEL MEMBERS IS PROHIBITED.
STEEL DECK NOTES
1. STEEL DECK MUST CONFORM TO THE LATEST EDITION OF AMERICAN IRON AND
STEEL INSTITUTE (AISI), “SPECIFICATION FOR THE DESIGN OF COLD-FORMED
STEEL STRUCTURAL MEMBERS” AND STEEL DECK INSTITUTE (SDI), “DESIGN
MANUAL FOR COMPOSITE DECK, FORM DECKS, AND ROOF DECKS”.
2. STEEL DECK GRATING MUST COMPLY WITH THE FOLLOWING:
A. 1 1/4" MIN. TO 2 1/2" MAX. THICK DECKING, ABLE TO WITHSTAND 150 PSF
B. STAINLESS STEEL TYPE 316 ALLOY
3. MAINTAIN 1” MINIMUM EDGE DISTANCE AT ALL CONNECTIONS.
FIXED METAL LADDER NOTES
1. PROVIDE A LADDER IN ACCORDANCE WITH THE REQUIREMENTS IN THE
EXECUTABLE SCOPE OF WORK DOCUMENT IN THE BID PACKAGE, THE
REQUIREMENTS OF ASCE 7 AND OSHA 29 CFR 1910.23 & 1926.1053, AND NAVY
FALL PROTECTION GUIDE FOR FIXED LADDERS. THESE REQUIREMENTS MUST
NOT BE MODIFIED BY ANSI-ASC A14.3-2008.
2. LADDER COMPONENTS MUST BE STAINLESS STEEL GRADE 316.
3. SUBMIT LADDER OSHA DOCUMENTATION OR DESIGN CALCULATIONS FOR
APPROVAL PRIOR TO FABRICATION. CALCULATIONS MUST BE STAMPED BY A
REGISTERED PROFESSIONAL ENGINEER.
STRUCTURAL ABBREVIATIONS NOTES
B.P. BASE PLATE
BLDG BUILDING
BOD BOTTOM OF DECK
BOT BOTTOM
BRCG BRACING
C CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
DEMO DEMOLISH
DOR DESIGNER OF RECORD
DIA (OR) Ø DIAMETER
DIM(S) DIMENSION(S)
DWGS DRAWINGS
E, EXIST EXISTING
E.W. EACH WAY
EA EACH
EF EACH FACE
EL, ELEV ELEVATION
EQ, EQUIV EQUAL, EQUIVALENT
FDN FOUNDATION
FF EL FINISHED FLOOR ELEVATION
FY ALLOWABLE YIELD STRESS
GA GAUGE
HDG, GALV HOT DIPPED GALVANIZED
HORIZ HORIZONTAL
HSS HOLLOW STRUCTURAL SHAPES
IAW IN ACCORDANCE WITH
INFO INFORMATION
INT INTERIOR
KSI KILOPOUNDS (KIPS) PER SQUARE INCH
L ANGLE
LB, LBS POUNDS
LF LINEAR FEET
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
MATL MATERIAL
MAX MAXIMUM
MD METAL DECK
MFR MANUFACTURER
MIN MINIMUM
MPH MILES PER HOUR
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OPH OPPOSITE HAND
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RE, REF REFERENCE
REINF REINFORCE, -MENT
REQD REQUIRED
SF SQUARE FEET
SIM SIMILAR
SPA SPACING
SPEC CONTRACT SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
THK THICKNESS
TO TOP OF
TOS TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/, W/O WITH, WITHOUT
~ , APPROX APPROXIMATELY
PLAN LEGEND
SY
M
DE
SC
RI
PT
IO
N
DA
TE
B3 S-101
15'
- 8
5/8
A1S-301
4' -
4' -
4' -
2' - 7 3/8"
10 1/2" 3' - 6"
TYP
6"
MLW
0' - 0"
1 2
1/4 TYP
1/4
TYP T&B FULL
LEN
3' - 1 3/8"
1/4 FULL LENGTH
1/2" THRU BOLTS, TYP.
NOTE: FENDERS NOT SHOWN
IN THIS VIEW.
7 12
S-301 B3
6"
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C N
AV
AL
S
TA
TI
O
N
N O
R
FO
LK
, V
A
AS NOTED
S-101
Q -5
D
A
TA
C O
N C
E N
TR
A
TO
R
S H
E D
R E
S
TO
R A
TI
O
N
DO
CK
IN
G
P
LA
TF
O
RM
DSG
12,937,905
ADB ADB
01/28/2026
COMMANDER, NAVY INSTILLATIONS COMMAND
DEAN S. GREGORY, P.E.
1673784
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
JOHN C. MILLER, P.E.
JAMES M. SMITH, R.A.
N/A
M
ID
LA
N
T R
O
IC
C N
O R
FO
LK
1/2" = 1'-0"B1 LOWER FRAMING PLAN
1" = 1'-0"B3 SECTION - SMALL VESSEL DOCK
1 PROVIDE W6X20 STEEL BEAM, TYP. FILLET WELD ALL AROUND TO EXISTING
VERTICAL CHANNEL.
2 PROVIDE C6X10.5 BEAM, TYP. ATTACH TO ENDS OF W6X20 BEAMS USING CLIP
ANGLES AND BOLTS AS SPECIFIED.
3 PROVIDE C15X40 STEEL VERTICAL SUPPORTS FOR FENDER ATTACHMENT,
TYP.
4 PROVIDE STEEL GRATING CAPABLE OF SUPPORTING 150 PSF OVER A 5-FT
SPAN. ATTACH TO TOP FLANGE OF NEW CHANNEL BEAMS PER
MANUFACTURER'S RECOMMENDATIONS.
5 EXISTING STEEL W8X26 BEAM. W8X26 ATTACHED TO EXISTING STEEL TUBE
PILE WITH MOMENT CONNECTION.
6 EXISTING 30" DIAMETER STEEL PIPE ELECTRICAL CONDUITS.
7 EXISTING 18" DIAM., 1/2" THICK STEEL PIPE PILE.
KEYNOTESGENERAL SHEET NOTES
1 VERIFY EXISTING STEEL SURFACES ARE ACCEPTABLE FOR RECEIVING WELDS
USING ULTRASONIC TESTING AFTER REMOVING LOOSE CORRODED
MATERIAL. IF SECTION LOSS FOR ANY MEMBER EXCEEDS 10%, INFORM THE
CONTRACTING OFFICER FOR REVALUATION OF PROJECT SCOPE.
2 VERIFY EXISTING STEEL WELDS ARE ACCEPTABLE FOR ADDITIONAL LOADING
USING ULTRASONIC TESTING AFTER REMOVING LOOSE CORRODED
MATERIAL. IF WELD THICKNESS IS REDUCED IN SIZE BY MORE THAN 10%,
INFORM THE CONTRACTING OFFICER FOR REVALUATION OF PROJECT SCOPE.
8 EXISTING STEEL W8X26 BEAM SUPPORT FOR FENDER SYSTEM TO REMAIN.
9 EXISTING C12X30 VERTICAL SUPPORT FOR FENDER SYSTEM TO REMAIN.
REMOVE EXISTING FOAM FENDER AND ATTACHMENT HARDWARE. TORCH CUT
TOP OF CHANNEL TO BE FLUSH WITH TOP FLANGE OF ADJACENT WIDE
FLANGE BEAM FOR GRATING TO SIT FLUSH. INSIDE FACE TO BE USED TO
SUPPORT NEW PLATFORM BEAMS.
10 PROVIDE 2L3X3X3/8 BRACE AT EACH PLATFORM SUPPORT, TYP.
11 PROVIDE NEW STEEL ACCESS LADDER WITH FALL ARREST SYSTEM PER
LADDER MANUFACTURER. RE: S-301 FOR DETAILS.
12 PROVIDE 1/2" GUSSET PLATES. WELD TO FLANGE OF STEEL CHANNEL, AND
THROUGH BOLT TO DOUBLE ANGLE BRACES. PROVIDE (2) BOLT HOLES FOR
1/2" BOLTED CONNECTION.
13 PROVIDE FOAM WING TYPE FENDER WITH MINIMUM OUTSIDE DIAMETER OF 8",
TYP. ATTACH TO C15X40 CHANNEL SUPPORTS PER MANUFACTURER'S
INSTRUCTIONS. FOR BIDDING PURPOSES ASSUME 1/2" THICK PLATE STRIP,
1-1/2" WIDE, THROUGH BOLTED INTO C15X40 EVERY 16" O.C.
14 PROVIDE 4" DIA X 1'-6" X-STRONG PIPE. REFER TO DETAIL B3/S-301 FOR MORE
INFORMATION.
SY
M
DE
SC
RI
PT
IO
N
DA
TE
2 3
13' - 0"±
3' - 0" ±
13'- 0" ±
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C N
AV
AL
S
TA
TI
O
N
N O
R
FO
LK
, V
A
AS NOTED
S-102
Q -5
D
A
TA
C O
N C
E N
TR
A
TO
R
S H
E D
R E
S
TO
R A
TI
O
N
CA
NN
IS
TE
R
IM
PR
O
VE
M
EN
TS
DSG
12,937,906
ADB ADB
01/28/2026
COMMANDER, NAVY INSTILLATIONS COMMAND
DEAN S. GREGORY, P.E.
1673784
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
JOHN C. MILLER, P.E.
JAMES M. SMITH, R.A.
N/A
M
ID
LA
N
T R
O
IC
C N
O R
FO
LK
1/2" = 1'-0"C1 PLATFORM LEVEL PLAN
1/2" = 1'-0"C2 ROOF LEVEL PLAN
KEYNOTESGENERAL SHEET NOTES
1 EXISTING 3/8" STEEL PLATE SHELL TO REMAIN.
2 EXISTING STEEL GRATED AND STEEL FRAMED ACCESS PLATFORM TO
REMAIN.
3 EXISTING STEEL BULKHEAD DOOR TO REMAIN.
4 EXISTING STEEL PIPE GUARDRAIL, TYP, TO REMAIN.
5 PROVIDE CLIMBING LADDER IN ACCORDANCE WITH THE 2024 EDITION
OF THE DEPARTMENT OF THE NAVY FALL PROTECTION GUIDE. FALL
ARREST SYSTEM MUST BE PROVIDED PER LADDER MANUFACTURER.
6 PROVIDE FALL ARREST SYSTEM IN ACCORDANCE WITH THE 2024
EDITION OF THE DEPARTMENT OF THE NAVY FALL PROTECTION GUIDE.
CONSIDER THE HIGHLY CORROSIVE ENVIRONMENT WHEN SELECTING
FALL ARREST SYSTEM HARDWARE.
1 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION, CONSTRUCTION, OR
ORDERING OF COMPONENTS.
2 PRE-MANUFACTURED COMPONENTS MUST MEET DEPARTMENT OF NAVY
FALL PROTECTION CODES AND CRITERIA.
7 PROVIDE METAL SELF-CLOSING SWING GATE IN ACCORDACE WITH THE
2024 EDITION OF THE DON FALL PROTECTION GUIDE. MOUNT TO
EXISTING GUARDRAIL POST.
8 DEEP CLEAN ROOFTOP SURFACE OF DCS SHELL TO REMOVE BIRD
GUANO, BIRD CARCASSES, AND OTHER WASTE MATERIAL. WASTE MUST
BE CONSIDERED HAZARDOUS AS BIRD GUANO AND WASTE COULD
CARRY DISEASE. COLLECT HAZARDOUS WASTE AND DISPOSE OF IN
ACCORDANCE WITH FEDERAL AND LOCAL GUIDANCE. WASTE MUST NOT
BE ALLOWED TO ENTER WATERWAY.
SY
M
DE
SC
RI
PT
IO
N
DA
TE
MLW
0' - 0"
BOC
14' - 0"
ROOF
32' - 0 3/4"
TOP OF PLATFORM
21' - 0 3/4"
6'
- 5
15'-10" ±
14 15
A3 S-301
6'
- 8
1" DIA BAR
4" DIA X 1' - 6"
LONG X-STRONG
PIPE
5/16" THICK PLATE
1'
- 0
1/ 4"
6"
6 1/2" DIA
TYP
6"
5/16 TYP
5/16TYP
5/16 TYP
TOP FLANGE OF
W6X20 BEAM.
STEEL BAR GRATING,
CUT TO PROVIDE
OPENING FOR
BOLLARD AS NEEDED.
C15X40 VERTICAL
CHANNEL OR FENDER
ATTACHMENT.
4"
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S C
O M
M
AN
D
M
ID
-A
TL
AN
TI
C N
AV
AL
S
TA
TI
O
N
N O
R
FO
LK
, V
A
AS NOTED
S-301
Q -5
D
A
TA
C O
N C
E N
TR
A
TO
R
S H
E D
R E
S
TO
R A
TI
O
N
SO
UT
H
EL
EV
AT
IO
N
DSG
12,937,907
ADB ADB
01/28/2026
COMMANDER, NAVY INSTILLATIONS COMMAND
DEAN S. GREGORY, P.E.
1673784
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
JOHN C. MILLER, P.E.
JAMES M. SMITH, R.A.
N/A
M
ID
LA
N
T R
O
IC
C N
O R
FO
LK
1/2" = 1'-0"A1 SOUTH ELEVATION
1 EXISTING STEEL PIPE GUARDRAIL, TYP, TO REMAIN.
2 PROVIDE METAL SELF-CLOSING SWING GATE IN ACCORDACE WITH THE
2024 EDITION OF THE DEPARTMENT OF THE NAVY FALL PROTECTION
GUIDE. MOUNT TO EXISTING GUARDRAIL POST.
3 DEEP CLEAN ROOFTOP SURFACE OF DCS SHELL TO REMOVE BIRD
GUANO, BIRD CARCASSES, AND OTHER WASTE MATERIAL. WASTE
MUST BE CONSIDERED HAZARDOUS AS BIRD GUANO AND WASTE
COULD CARRY DISEASE. COLLECT HAZARDOUS WASTE AND DISPOSE
OF IN ACCORDANCE WITH FEDERAL AND LOCAL GUIDANCE. WASTE
MUST NOT BE ALLOWED TO ENTER WATERWAY.
4 EXISTING STEEL BULKHEAD DOOR TO REMAIN.
5 PROVIDE STEEL CLIMBING LADDER IN ACCORDANCE WITH THE 2024
EDITION OF THE DEPARTMENT OF THE NAVY FALL PROTECTION GUIDE.
FALL ARREST SYSTEM MUST BE PROVIDED PER LADDER
MANUFACTURER.
6 EXISTING 3/8" STEEL PLATE SHELL TO REMAIN.
7 EXISTING STEEL GRATED AND STEEL FRAMED ACCESS PLATFORM TO
REMAIN.
8 EXISTING STEEL ANGLE PLATFORM SUPPORT STRUTS, TYP, TO
REMAIN.
9 PROVIDE FALL ARREST SYSTEM IN ACCORDANCE WITH THE 2024
EDITION OF THE DEPARTMENT OF THE NAVY FALL PROTECTION GUIDE.
CONSIDER THE HIGHLY CORROSIVE ENVIRONMENT WHEN SELECTING
FALL ARREST SYSTEM HARDWARE.
10 ANCHORAGE PER LADDER MANUFACTURER, TYP. FOR BID PURPOSES
ASSUME L8X2X3/8" WELDED TO LADDER RAIL AND 3/8" DCS SHELL
PLATE, TYP.
11 EXISTING STEEL FRAMED PILE CAP. TYP, TO REMAIN.
12 EXISTING 18" DIAM., 1/2" THICK STEEL PIPE PILE TO REMAIN.
13 PROVIDE STEEL GRATING CAPABLE OF SUPPORTING 150 PSF OVER A
5-FT SPAN. ATTACH TO TOP FLANGE OF NEW CHANNEL BEAMS PER
MANUFACTURER'S RECOMMENDATIONS.
14 PROVIDE C6X10.5 BEAM, TYP. ATTACH TO ENDS OF W6X20 BEAMS
USING CLIP ANGLES AND BOLTS AS SPECIFIED. ENSURE TOS IS FLUSH.
15 PROVIDE C15X40 STEEL VERTICAL SUPPORTS FOR FENDER
ATTACHMENT, TYP.
16 PROVIDE FOAM WING TYPE FENDER WITH MINIMUM OUTSIDE
DIAMETER OF 8", TYP.. ATTACHMENT TO C15X40 CHANNEL SUPPORTS
PER MANUFACTURER'S INSTRUCTIONS. FOR BIDDING PURPOSES
ASSUME 1/2" THICK PLATE STRIP, 1 1/2" WIDE, THROUGH BOLTED INTO
C15X40 EVERY 16" O.C.
17 PROVIDE PRE-MANUFACTURED STEEL SECURITY CAGE. ATTACH TO
NEW LADDER SIDE RAILS.
18 PROVIDE PRE-MANUFACTURED STEEL SECURITY HATCH. ATTACH TO
STEEL SECURITY CAGE PER MANUFACTURER'S INSTRUCTIONS. HATCH
MUST NOT INTERFERE WITH FALL ARREST SYSTEM TRACK OR CABLE.
19 SECURITY HATCH HINGE PER MANUFACTURER.
20 PROVIDE 4" DIA X 1'-6" X-STRONG PIPE. REFER TO DETAIL B3/S-301 FOR
MORE INFORMATION.NOT TO SCALE (S-301)A3 STEEL SECURITY CAGE AND HATCH
STRUCTURAL KEYNOTES
GENERAL SHEET NOTES
1 THE DATUM ELEVATION FOR THIS DRAWING IS REFERENING FROM MLW
= 0' - 0". THE VERTICAL DISTANCE ABOVE DATUM IS NOTED THUS: X'- X".
NOT TO SCALE (S-101)B3 DETAIL - BOLLARD CONNECTION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
| Sheets |
| G-001 - COVER SHEET |
| S-001 - STRUCTURAL SYMBOLS, LEGENDS,ABBREVIATIONS, AND NOTES |
| S-101 - DOCKING PLATFORM |
| S-102 - CANNISTER IMPROVEMENTS |
| S-301 - SOUTH ELEVATION |
2026-02-03T10:58:49-0500
2026-02-03T10:58:49-0500
2026-02-03T10:58:50-0500
2026-02-03T10:58:50-0500
2026-02-03T10:58:50-0500
2026-02-03T10:59:30-0500
2026-02-03T10:59:30-0500
2026-02-03T10:59:31-0500
2026-02-03T10:59:31-0500
2026-02-03T10:59:31-0500
File details come from the government source that posted it. Updated .