Attachment B Plans~3.pdf

PDF 29 MB Posted

Attached to
ITB for Seclusion Room Renovation Oregon State Hospital, Junction City
Solicitation number
S-44300-00010048
Issued by
Lane County, Jacksonville City, Oregon

About this file

This document is the Attachment B Plans for an Invitation to Bid (ITB) for the Seclusion Room Renovation project at the Oregon State Hospital in Junction City, Oregon. The project is being solicited by Lane County. The ITB requests bids for the renovation of seclusion rooms at the state hospital facility. The plans provide detailed specifications and drawings for the proposed work. The bid submission deadline is March 15, 2023, and the anticipated contract award date is April 1, 2023. The contract term is one year with the option to renew for up to four additional one-year terms.

The ITB does not specify any pricing terms, set-asides, incumbent contractors, or funding details. However, it indicates that the project is being funded through state and local sources, though the exact amounts are not provided. Bidders must meet all qualification requirements outlined in the solicitation documents to be considered for award.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page 44 DM1735383-v3

DAS General Conditions (1/1/2012)

ATTACHMENT B - PLANS

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

/1

/2

:2 :2

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

G000

COVER SHEET -

SECLUSION ROOM

NUMBER DESCRIPTION DATE

SECLUSION ROOM RENOVATION

OREGON STATE HOSPITAL

JUNCTION CITY

100% CONSTRUCTION DOCUMENTS

September 15, 2022

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

Y

DRAWING TITLEBAR:

DRAWING

IDENTIFICATION

DRAWING

TITLE

GRAPHIC SYMBOLS:

CALLED NORTH

TRUE NORTH

PROPERTY

LINE

DRAWING REFERENCE

SYMBOL:

REFER TO THIS

DRAWING

IDENTIFICATION

REFER TO THIS

SHEET:

SHEET NUMBER

CATEGORY

DISCIPLINE

REFER TO THIS

DRAWING IDENTIFICATION

BUILDING / WALL SECTION

REFERENCE:

COLUMN CENTER

LINE

COLUMN GRID

NUMBER

DRAWING IDENTIFICATION

SHEET IDENTIFICATION

EXTERIOR ELEVATIONS INTERIOR ELEVATIONS

DETAIL REFERENCE:

REFER TO THIS

DRAWING IDENTIFICATION

SPACE NAME / NUMBER SYMBOL:

ROOM

NAME

SPACE

IDENTIFICATION

SPACE NUMBER

PARTITION/ DOOR TYPE SYMBOLS:

DOOR NUMBER

WINDOW TAG

REVISION SYMBOLS:

REVISED AREA

REVISION NUMBER

NOTE: INDICATES

FINISHED SURFACES

SHALL ALIGN

NOTE: INDICATES

+/- FROM REF ELEVATION

DIMENSION POINT

FL ELEVATION

GRAPHIC ARROWS:

ALIGN

TITLE

SCALE: 1/8" = 1'-0"

ORIGINAL SCALE

N

A1

A201-B

A1

A201

A2

A501

MATCHLINE SEE: 1 / A201-B

A1000

+12"

DP

FF EL

0' - 0"

1 1/4" 5' - 0"

0 3 / 4"

R 3

0"

A

1 1.1

DIMENSION LINES:

PARTITION TYPE TAG A4-BC/C

DRAWING ANNOTATIONS

A200

A1 A200

A200

A

SHEET: A201-B SHEET NUMBER

KEY NOTE BY

SPEC DIV

A500

A3

09600.0

WINDOW TYPE

i

R A 3

WINDOW TAG:

A. GENERAL NOTES:

1. THE CONTRACTOR SHALL PROVIDE COMPLETE PROJECT SYSTEMS AND COMPONENTS AND COMPLY

WITH ALL REQUIREMENTS INDICATED ON THE PROJECT DOCUMENTS.

2. WORK WITHIN THE AREA BOUNDARIES INDICATED IN THE PROJECT DOCUMENTS, AND COMPLY WITH ALL APPLICABLE BUILDING CODE, REGULATION, & ORDINANCE REQUIREMENTS. OCCUPANTS ADJACENT

TO THE PROJECT AREA BOUNDARIES SHALL CONTINUE UNINTERRUPTED OCCUPANCY DURING

CONSTRUCTION OF THE PROJECT

3. VERIFY FIELD CONDITIONS AND COORDINATION WITH THE PROJECT DOCUMENTS PRIOR TO

PROCEEDING WITH THE WORK.

4. COORDINATE THE WORK WITH ALL REQUIREMENTS INDICATED IN THE PROJECT DOCUMENTS.

5. PERFORM THE WORK AT THE PROJECT SITE DURING NORMAL BUSINESS HOURS, UNLESS OTHERWISE

NOTED.

6. COORDINATE THE WORK WITH EQUIPMENT, FURNISHINGS, AND SYSTEMS PROVIDED BY THE OWNER.

B. DEFINITIONS:

1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM SHALL BE PROVIDED FOR EACH

OCCURRENCE OF THE CONDITION NOTED.

2. "SIMILAR" INDICATES COMPLETE SYSTEM AND COMPONENTS SHALL BE PROVIDED COMPARABLE TO

THE CHARACTERISTICS FOR THE CONDITION NOTED.

3. "AS REQUIRED" INDICATES COMPONENTS REQUIRED TO COMPLETE THE NOTED, SYSTEM AS

INDICATED IN THE PROJECT DOCUMENTS, SHALL BE PROVIDED.

4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND

PLUMB RELATION TO ADJACENT MATERIALS.

C. DIMENSIONS:

1. DIMENSIONS ARE INDICATED TO THE CENTERLINE OF THE STRUCTURAL GRID, FACE OF CONCRETE

WALL, NOMINAL FACE OF CMU WALL, FACE OF PARTITION TYPE AS SCHEDULED, UON

2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. THE

PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER:

A .MIN DIMEN FOR ACCESSIBILITY CLEARANCE & BUILDING CODE REQMT

B .LARGE SCALE DETAILS

C .SMALL SCALE DETAILS

D .ENLARGED VIEWS

E .FLOOR PLANS AND ELEVATIONS

3. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE

NOTED.

4. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL

AT THE DIMEN POINT, UNLESS NOTED ABOVE FINISH FLOOR -"AFF".

5. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED

SUSPENDED CEILING SYSTEM OR FACE OF FINISH MATERIAL AS SCHEDULED

6. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, CLEARANCE, AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND COMPONENTS. DIMENSIONS SHALL

NOT BE DETERMINED BY SCALING THE DRAWINGS.

D. DRAWING SET ORGANIZATION:

1. EACH DRAWING SET SHEET IS IDENTIFIED BY THE SHEET NUMBER IN THE LOWER RIGHT HAND

CORNER OF THE DRAWING TITLE BLOCK. THE SHEET TITLE PROVIDES A GENERAL DESCRIPTION OF

THE CONTENTS OF THE SHEET.

SHEET NUMBER EXAMPLE: A201

"A" INDICATES THE DISCIPLINE THAT CREATED THE DRAWING

"2" INDICATES THE DRAWING CATEGORY CONTAINED ON THE SHEET

"01" INDICATES THE SHEET NUMBER

2. SHEET NUMBERS MAY INCLUDE SUPPLEMENTAL CHARACTERS TO PROVIDE ADDITIONAL INFORMATION, SUCH AS DRAWING CONTENT, PROJECT SECTOR OR PHASE. REFER TO THE DRAWING INDEX FOR A

COMPLETE LIST OF SHEETS INCLUDED IN THE DOCUMENT SET.

EXAMPLE: EL201-A

"EL" INDICATES THE DISCIPLINE THAT CREATED THE DRAWING AND THE DRAWING CONTENT =

ELECTRICAL LIGHTING

"A" INDICATES SECTOR "A" OF PLAN SHEET "201". REFER TO THE PROJECT KEY PLAN OR

COMPOSITE PLAN INDICATING THE RELATIONSHIP OF THE SECTORS.

"D" INDICATEDS DEMOLITION, FOR EXAMPLE, " EFD" INDICATES ELECTRICAL FIRE ALARM DEMOLITION.

3. DRAWING SET INDEX INDICATES THE COMPLETE LIST OF SHEETS CONTAINED IN THE DRAWING SET, INDEXED BY DISCIPLINE, SHEET NUMBER AND SHEET TITLE, IN SEQUENTIAL ORDER. NOTE THAT ALL

SEQUENTIAL SHEET NUMBERS MAY BE NOT USED IN THE DRAWING SET.

4. DISCIPLINE IDENTIFICATION, IN ORDER BOUND IN THE DRAWING SET. REFER TO THE DRAWING SET

INDEX FOR DISCIPLINE CONTAINED IN THIS DRAWING SET:

G GENERAL INFORMATION

A ARCHITECTURAL

P PLUMBING

M MECHANICAL

FP FIRE PROTECTION

E ELECTRICAL

T TELECOMMUNICATIONS

GENERAL NOTES

M F

LT

R V

A

C1700

C1800

C1900

M F T L R V A

C1700 C1800 C1900

= MOUTAIN (HOSP), ROOMS 1500-1599

= COTTAGE 1 (RTF), ROOMS 1700-1799

= FOREST (SRTF), ROOMS 1600-1699

= TREATMENT MALL, ROOMS 1300-1399

= LAKE, ROOMS 1400-1499

= RIVER, ROOMS 1100-1199

= VALLEY, ROOMS 1200-1299

= ADMINISTRATION, ROOMS 1000-1099

= COTTAGE 2 (RTF), ROOMS 1800-1899

= COTTAGE 3 (RTF), ROOMS 1900-1999

ZONE NAMES

ROOM NUMBERS

ZONE NAME

FLOOR LEVEL

ROOM NUMBER

M 1 2 3 8

MQ PQ FQ

VQ

QUAD NAMES

MQ

PQ

FQ

VQ

= MOUTAIN QUAD

= PRAIRIE QUAD

= FOREST QUAD

= VALLEY QUAD

RECREATION

FIELD

COTTAGE 1

HOUSING / MALL

COTTAGE 2

COTTAGE 3

AREA A AREA B

AREA C

AREA D

FUTURE GREENHOUSE

ADMIN / CUP

DINING / VOC / WAREHOUSE

AREA E

CODE SUMMARY

APPLICABLE CODES AND AGENCIES

APPLICABLE CODES

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LISTED APPLICABLE CODES

IN ADDITION TO ALL LOCAL AND STATE CODES, ALL WORK SHALL COMPLY WITH THE 2010 ACCESSIBILITY REQUIREMENTS OF THE STATE OF OREGON ADMINISTRATIVE CODE AND THE 2010 AMERICANS WITH

DISABILITIES ACT (ADA). REFER TO ACCESSIBILITY REQUIREMENTS SHEET FOR FURTHER

REQUIREMENTS.

APPLICABLE CODES AND

REGULATIONS

CODE AREA 'A'

USE: PSYCHIATRIC FACILITY

2019 OREGON STRUCTURAL SPECIALITY CODE WHICH AMENDS THE 2018 (IBC)

2019 OREGON MECHANICAL SPECIALITY CODE WHICH AMENDS THE 2018 (IMC)

2017 OREGON PLUMBING SPECIALITY CODE WHICH AMENDS THE 2015 (UPC)

2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE

2021 OREGON ELECTRICAL SPECIALITY CODE WHICH AMENDS THE 2020 (NEC)

2018 OREGON FIRE CODE WHICH AMENDS THE 2009 (IFC)

2012 NFPA 101, LIFE SAFETY CODE, CHAPTER 18, NEW HEALTH CARE OCCUPANCIES

2016 NFPA 13 FIRE SPRINKLERS

2016 NFPA 72 FIRE ALARM

2010 NFPA 10 FIRE EXTINGUISHERS

2011 NFPA 25 FIRE SPRINKLERS TESTING & MAITENANCE

2011 NFPA 70 NATIONAL ELECTRICAL CODE

ASHRAE 170 VENTILATION OF HEALTHCARE FACILITIES

VICINITY MAP

LOCATION MAP

N

N

N

PROJECT INFORMATION

PROJECT LOCATION:

92213 DREAS WAY

JUNCTION CITY, OR 97448

OREGON BUILDING CODES DIVISION

CITY OF JUNCTION CITY

OFFICE OF THE STATE FIRE MARSHALL

LANE RURAL FIRE/RESCUE

JUNCTION CITY RURAL FIRE PROTECTION DISTRICT

DHS PUBLIC HEALTH DIV FACILITIES PLANNING

DHS MENTAL HEALTH DIVISION

JURISDICTIONS

308.3 OCCUPANCY: I-2 (HOSPITAL BEDS)

407.4 SMOKE COMPARTMENTS: 22,500 SF MAX

407.4.1 REFUGE AREA: 30 SF/ 6 SF NET

407.8 SECURE YARDS: 30 NET / 6 NET / 50 FT AWAY

508.2.5 OCCUPANCY SEPARATIONS

LAUNDRY RMS (100SF+) 0-HOUR

WASTE RMS 1-HOUR FIRE BARRIER

LINEN RMS 1-HOUR FIRE BARRIER

710 SMOKE COMPARTMENT WALL: 1-HOUR SMOKE BARRIER

711 CORRIDOR WALL: 0-HOUR SMOKE PARTITION

503 TYPE OF CONSTRUCTION: TYPE IIA

903.3.1.1 FIRE RESISTIVE SYSTEM: FULLY SPRINKLED BUILDING NFPA 13

907.2.6.2 FIRE ALARM SYSTEM I-2 SUPERVISED SYSTEM

ALLOWABLE FLOOR AREA: 51,900 SF PER STORY

ACTUAL FLOOR AREA:

FLOOR 1 51,240 SF

FLOOR 2 35,955 SF

FLOOR 3 35,955 SF

TOTAL 123,150 SF

ALLOWABLE NUMBER OF STORIES: 3 STORIES + PENTHOUSE

ACTUAL NUMBER OF STORIES: 3

ALLOWABLE BUILDING HEIGHT: 65 FT

ACTUAL BUILDING HEIGHT: 52 FT

ACTUAL HIGHEST OCCUPIED FLOOR LEVEL : 25 FT

601 FIRE RESISTANCE RATINGS

STRUCTURAL FRAME 1-HOUR (2-HOUR AT OCC. AND BLDG. SEPARATIONS)

EXTERIOR BEARING WALL 1-HOUR

INTERIOR BEARING WALL 1-HOUR

NON-BEARING WALL 0-HOUR

FLOOR CONSTRUCTION 1-HOUR

ROOF CONSTRUCTION 1-HOUR

BUILDING SEPARATION 2-HOUR FIRE WALL

EXIT STAIR 1-HOUR FIRE BARRIER

PENTHOUSE 0-HOUR

SHAFT 1-HOUR FIRE BARRIER

803.9 FINISHES

I-2 CLASS B

I-2 ADMIN SPACES CLASS C

I-2 SMALL SPACES CLASS C (LESS THAN 4 PERSONS)

3006.4 ELEVATOR MACHINE ROOMS

0-HOUR EXC. 2: WHERE MACHINE ROOMS ARE NOT

ADJACENT/COMMON WALL WITH HOIST WAY

1-HOUR WRAP (WALLS/SLAB/CEILING)

D R

E A

S W

A Y

NAME AND NUMBER SYSTEM

N

HOSPITAL LICENSING CODES

OREGON ADMINISTRATIVE RULES

PROJECT SITE

PROJECT SITE

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

/1

/2

:2 :2

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

G100

VICINITY MAPS,

PROJECT INFO,

GENERAL NOTES

NUMBER DESCRIPTION DATE

SCOPE OF WORK:

RENOVATION IN TWO LOCATIONS OF TWO INTERIOR ROOMS INTO A THREE ROOM

SECULSION ROOM SUITE WITH ANTE ROOM AND TOILET ROOM ON THE FIRST AND SECOND

FLOORS. NO CHANGE IN USE, SQUARE FOOTAGE, OR TYPE OF CONSTRUCTION.

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A

29398 RECOVERY WAY

1 2 3 4 5

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

/1

/2

:2 :2

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

G101

KEYNOTE MASTER

LIST AND ROOM AND

ARCHITECTURAL

ABBREVIATIONS

STL STEEL

STLJST STEEL JOIST

STOR STORAGE

STRG STRINGER

STRL STRUCTURAL

STRUC STRUCTURAL

STRUC

SUBCAT

STRUCTURAL SUBCATEGORY

STS SELF TAP SHEET METAL SCREW

SUSP SUSPENDED

SYMM SYMMETRICAL

SYS SYSTEM

T

T TREAD / THERMOSTAT

T&G TONGUE AND GROOVE

TB TOWEL BAR

TC TOP OF CURB

TCONC TOP OF CONCRETE

TEL TELEPHONE OR TELECOM

TEMP TEMPERATURE

TER TERRAZZO

TGB TOGGLE BOLT

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

TKBD TACKBOARD

TLT SHWR

PAT

PATIENT TOILET & SHOWER

TMPD TEMPERED

TO TOP OF (SEE OTHER WORD)

TOS TOP OF SLAB, TOP OF STRUCTURE

TOSTL TOP OF STEEL

TP TOP OF PAVEMENT

TPD TOILET PAPER DISPENSER

TRACT TRACTION

TV TELEVISION

TW TOP OF WALL

TYP TYPICAL

U

UNFIN UNFINISHED

UON UNLESS OTHERWISE NOTED

UR URINAL

V

VAC VENTILATION AND AIR CONDITIONING

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VR VAPOR RETARDER

VT VINYL TILE

VWC VINYL WALL COVERING

W

W WIDE/WIDTH, WEST, WIDEFLANGE

W/ WITH

W/O WITHOUT

WB WALL BASE, WEIGHTED BASE

WC WATER CLOSET

WD WOOD

WDP WOOD PANEL

WDS WOOD SCREW

WDW WINDOW

WM WALK-OFF MAT

WP WATERPROOFING

WP WALL PROTECTION

WPM WATERPROOF MEMBRANE

WPT WORK POINT

WR WATER RESISTANT/REPELLANT

WS WEATHERSTRIPPING

WSCT WAINSCOT

WT WEIGHT

WW WALL TO WALL

MRF MECHANICAL FLOORING

MS MACHINE SCREW

MSC METAL SECURITY CEILING

MTD MOUNTED

MTG MOUNTING

MTL METAL (SST)

MULL MULLION

N

N NORTH, OR NEWTON

NA NOT APPLICABLE

NC NOISE CRITERIA

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NPS NOMINAL PIPE SIZE

NTS NOT TO SCALE

O

OA OUTSIDE AIR

OC ON CENTER

OCC OCCUPANCY

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER/DIMENSION

OFCI OWNER FURNISHED, CONTR INSTALLED

OFF OFFICE

OFOI OWNER FURNISHED, OWNER INSTALLED

OH OVER HEAD

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPPHD OPPOSITE HAND

ORD OVERFLOW ROOF DRAIN

OUTS OUTSIDE

OVHD OVERHEAD

P

P PAINT

PARTN PARTITION

PATD PAPER TOWEL DISPENSER

PAV PAVING

PBD PARTICLEBOARD

PC PRECAST CONCRETE

PDF POWDER DRIVEN FASTENER

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PF POINT OF FROG

PF PADDED FLOORING

PFPI PROJECT FURNISHED, PROJECT

INSTALLED

PL PLATE

PL PLASTIC LAMINATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLF POUNDS PER LINEAR FOOT

PLYWD PLYWOOD

PNL PANEL

POL POLISHED

PP PHENOLIC PANEL

PR PAIR

PREFAB PREFABRICATED

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PT POINT

PT PORCELAIN TILE

PTD PAINTED

PTN PARTITION

PTR PAPER TOWEL RECEPTACLE

PW PADDED WALL

Q

QT QUARRY TILE

QTY QUANTITY

R

(R) RELOCATED

R RADIUS OR RISER (PIPING)

RA RETURN AIR

RAD RADIUS

RB RESILIENT BASE

RB RUBBER BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REC RECESSED

RECOM RECOMMENDED

RECPT RECEPTACLE

REF REFERENCE

REFL REFLECTED / REFLECTIVE / REFLECT

REFR REFRIGERATOR

REG REGISTER

REINF REINFORCED / REINFORCING

REL RELOCATE

REM REMOVABLE

REQ REQUIRE / REQUIRED

RESIL RESILIENT

REV REVISION / REVISED

RF RESINOUS FLOORING

RM ROOM

RO ROUGH OPENING

RP RESIN PANEL

RS RESILIENT SHEET FLOORING

RT RESILIENT TILE FLOORING

RTD RATED

RTG RATING

RWL RAIN WATER LEADER

S

S SOUTH

SA SUPPLY AIR

SAN SANITARY

SC SOLID CORE

SCHED SCHEDULE

SD STORM DRAIN / SOAP DISPENSER

SECL SECLUSION

SECT SECTION

SF SQUARE FEET/FOOT

SF SPORTS FLOORING

SH SPRINKLER HEAD

SHR SHOWER

SHT SHEET

SIM SIMILAR

SM SHEET METAL OR SQUARE METER

(METRIC DOCS)

SMS SHEET METAL SCREW

SND SANITARY NAPKIN DISPENSER

SP STANDPIPE

SPEC SPECIFICATION

SPKR SPEAKER

SPR SPRINKLER

SQ SQUARE

SS SOLID SURFACE

SSD SEE STRUCTURAL DRAWINGS

SSE STRUCTURE SLAB ELEVATION

SSK SERVICE SINK

SST STAINLESS STEEL

STA STATION

STD STANDARD

F

F FABRIC

FA FIRE ALARM

FB FACE BRICK

FC FACE

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF&E FURNITURE, FINISHES & EQUIPMENT

FFEL FINISH FLOOR ELEVATION

FFP FIXED FUNITURE & EQUIPMENT

FH FLAT HEAD

FHMS FLAT HEAD METAL SCREW

FHV FIRE HOSE VALVE CABINET

FIN FINISH

FIXT FIXTURE

FL FLOOR

FLASH FLASHING

FLB FLOOR BOX

FLUOR FLUORESCENT

FO FACE OF

FP FIRE PROTECTION

FPG FIREPROOFING

FR FRAME

FRP FIBER REINFORCED PLASTIC PANEL

FRTW FIRE RETARDANT TREATED WOOD

FSZV FIRE SPRINKLER ZONE VALVE CABINET

FT FEET

FTG FOOTING

FURN FURNITURE

FURR FURRING

FWC FABRIC WALL COVERING

FWP FABRIC WRAPPED PANEL

G

G GROUND

GA GAUGE / GAGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACT(OR)

GL GLASS

GR GRADE

GRC GLASS FIBER REINFORCED CONCRETE

GRD GROUND

GRG GLASS FIBER REINFORCED GYPSUM

GYP BD GYPSUM WALLBOARD

H

H HIGH / HEIGHT

HB HOSE BIBB

HC HOLLOW CORE

HCP HANDICAPPED

HDW HARDWARE

HDWD HARDWOOD

HM HOLLOW METAL (STEEL FRAME)

HNDRL HANDRAIL

HO HOLD-OPEN

HORIZ HORIZONTAL

HPT HIGH POINT

HR HOUR

HRC HOSE REEL CABINET

HS HEAT STRENGTHENED (GLASS)

HSS HOLLOW STRUCTURAL SECTION

HT HEIGHT

HVAC HEATING, VENTILATING, AIR

CONDITIONING

HW HOT WATER

HYDR HYDRAULIC

I

ID INSIDE DIAMETER / DIMENSION

IN INCH

INCAND INCANDESCENT

INCL INCLUDED / INCLUDING

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERM INTERMEDIATE

INV INVERT

IPS INTERNATIONAL PIPE STANDARD

IRMA INVERTED ROOF MEMBRANE ASSEMBLY

J

JAN JANITOR

JC JANITOR'S CLOSET

JST JOIST

JT JOINT

K

K KIP (1000 LB)

KG KILOGRAM

KIT KITCHEN

KO KNOCKOUT

KPL KICK PLATE

L

L LONG OR LITER (METRIC DOCS)

LAB LABORATORY

LAM LAMINATE / LAMINATION

LAV LAVATORY

LB POUND

LDG LANDING

LF LINEAR FOOT

LIN LINOLEUM

LKR LOCKER

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LN LINE

LPT LOW POINT

LT LIGHT

M

M METER, METRIC

MACH MACHINE

MAINT MAINTENANCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MBL MARBLE

MDF MEDIUM DENSITY FIBERBOARD

MDO MEDIUM DENSITY OVERLAY PLYWOOD

MECH MECHANICAL

MEMB MEMBRANE

MEP MECHANICAL, ELECTRICAL, PLUMBING

MET METAL

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

A

AB ANCHOR BOLT

AC AIR CONDITIONING

ACC ACCESSIBLE

ACOUS ACOUSTICAL

ACP ACOUSTIC CEILING PANEL

AD AREA DRAIN

ADD ADDITIONAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

AGGR AGGREGATE

ALT ALTERNATE

ALUM ALUMINUM

ANCH ANCHOR

ANNO ANODIZED

APC ACOUSTICAL PANEL CEILING

APPD APPROVED

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ATC ACOUSTICAL TILE CEILING

AUTO AUTOMATIC

AV AUDIO VISUAL

AXON AXONOMETRIC PROJECTION

B

BD BOARD

BEJ BRICK EXPANSION JOINT

BLDG BUILDING

BLK BLOCK

BM BEAM

BOT BOTTOM

BRK BRICK

BSMT BASEMENT

BT BOLT

BUR BUILTUP ROOFING

C

CAB CABINET

CAT CATEGORY

CB CATCH BASIN

CBD CHALK BOARD

CBU CEMENTATIONS BACKER UNIT

CC CUBICLE CURTAIN

CEM CEMENT

CER CERAMIC

CFP CELLULOSE FIBER PANEL

CG CORNER GUARD

CG CORNER GUARD

CH CHILLER

CHAN CHANNEL

CI CAST IRON

CIP CASTINPLACE

CJ CONTROL JOINT / CONSTRUCTION JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

CO CLEANOUT

COL COLUMN

COMPART COMPARTMENT

CONC CONCRETE

COND CONDITION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CP CELLULAR POLYCARBONATE

CPT CARPET TILE

CR CRASH RAIL

CS CONCRETE SEALED

CT CERAMIC TILE / COOLING TOWER

CTR CENTER

CTSK COUNTER SUNK

CW COLD WATER (PIPING)

D

D DEEP, DEPTH

DA DISABLED

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIFF DIFFUSER

DIM DIMENSION

DIS DISABLED

DISP DISPENSER

DMPF DAMP PROOFING

DMT DEMOUNTABLE

DN DOWN

DO DOOR OPENING

DP DIMENSION POINT

DPTN DEMOUNTABLE PARTITION

DR DOOR

DRN DRAIN

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

DWR DRAWER

E

(E) EXISTING

E EAST

EA EACH

EB EXPANSION BOLT (EXPANSION ANCHOR)

EFS EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION AND FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

EMERG EMERGENCY

ENCL ENCLOSURE

EP ELECTRICAL PANEL BOARD

EQ EQUAL

EQUIP EQUIPMENT

ESCAL ESCALATOR

EWC ELECTRICAL WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

ARCHITECTURAL / INTERIORS ABBREVIATION

NUMBER DESCRIPTION DATE

T001 TELECOMMUNICATION & SECURITY SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

TD201-B TELECOMMUNICATIONS & SAFETY DEMOLITION PLAN LEVEL 1 - SECTOR B

TD202-B TELECOMMUNICATIONS & SAFETY DEMOLITON PLAN LEVEL 2 - SECTOR B

T201 TELECOMMUNICATIONS & SECURITY PLAN LEVEL 1 - COMPOSITE

T201-B TELECOMMUNICATION & SECURTIY PLAN LEVEL - SECTOR B

T202 TELECOMMUNICATIONS & SECURITY PLAN LEVEL 2 - COMPOSITE

T202-B TELECOMMUNICATIONS & SECURITY PLAN LEVEL 2 - SECTOR B

T610 TELECOMMUNICATION & SECURITY DETAILS

E001 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

E501 ELECTRICAL SCHEDULES

EFD201-B ELECTRICAL FIRE ALARM DEMOLITION PLAN LEVEL 1 - SECTOR B

EFD202-B ELECTRICAL FIRE ALARM DEMOLITION PLAN LEVEL 2 - SECTOR B

EF101 ELECTRICAL FIRE ALARM ZONING PLAN LEVEL 1

EF102 ELECTRICAL FIRM ALARM ZONING PLAN LEVEL 2

EF201-B ELECTRICAL FIRE ALARM PLAN LEVEL 1 - SECTOR B

EF202-B ELECTRICAL FIRE ALARM PLAN LEVEL 2 - SECTOR B

EP201 ELECTRICAL POWER PLAN LEVEL 1 - COMPOSITE

EP202 ELECTRICAL POWER PLAN LEVEL 2 - COMPOSITE

ELD201-B ELECTRICAL LIGHTING DEMOLITION PLAN LEVEL 1 - SECTOR B

ELD202-B ELECTRICAL LIGHTING DEMOLITION PLAN LEVEL 2 - SECOR B

EL201 ELECTRICAL LIGHTING PLAN LEVEL 1 - COMPOSITE

EL201-B ELECTRICAL LIGHTING PLAN LEVEL 1 - SECTOR B

EL202 ELECTRICAL LIGHTING PLAN LEVEL 2 - COMOSITE

EL202-B ELECTRICAL LIGHTING PLAN LEVEL 2 - SECTOR B

EPD202-B ELECTRICAL POWER DEMOLITION PLAN LEVEL 2 - SECTOR B

EPD201-B ELECTRICAL POWER DEMOLITION PLAN LEVEL 1 - SECTOR B

EP201-B ELECTRICAL POWER PLAN LEVEL 1 - SECTOR B

EP202-B ELECTRICAL POWER PLAN LEVEL 2 - SECTOR B

E701 ELECTRICAL DRAWINGS

FP001 FIRE PROTECTION - SYMBOLS, ABBREVIATIONS AND NOTES

FP002 FIRE PROTECTION - SCHEDULES AND DETAILS

FP201 FIRE PROTECTION FLOOR PLAN - LEVEL 1 - COMPOSITE

FP202 FIRE PROTECTION FLOOR PLAN - LEVEL 2 - COMPOSITE

MD201-B MECHANICAL - DEMOLITION FLOOR PLAN - LEVEL 1 - SECTOR B

MD202-B MECHANICAL - DEMOLITION FLOOR PLAN - LEVEL 2 - SECTOR B

M601 MECHANICAL DETAILS

M001 MECHANICAL LEGEND ABBREVIATIONS & GENERAL NOTES

M002 MECHANICAL LEGEND ABBREVIATIONS & GENERAL NOTES

M201 MECHANICAL - FLOOR PLAN - LEVEL 1 - COMPOSITE

M201-B MECHANICAL - FLOOR PLAN - LEVEL 1 - SECTOR B

M202 MECHANICAL - FLOOR PLAN - LEVEL 2 - COMPOSITE

M202-B MECHANICAL - FLOOR PLAN - LEVEL 2 SECTOR B

M501 MECHANICAL EQUIPMENT SCHEDULE

M502 MECHANICAL EQUIPMENT SCHEDULE

P001 PLUMBING - SYMBOLS, ABBREVIATIONS AND NOTES

P002 PLUMBING - SCHEDULES

P200 PLUMBING - UNDERFLOOR PLAN - COMPOSITE

P200-B PLUMBING - UNDERFLOOR PLAN - SECTOR B

P201 PLUMBING - FLOOR PLAN - LEVEL 1 - COMPOSITE

P201-B PLUMBING - FLOOR PLAN - LEVEL 1 - SECTOR B

P202 PLUMBING - FLOOR PLAN - LEVEL 2 - COMPOSITE

P202-B PLUMBING - FLOOR PLAN - LEVEL 2 - SECTOR B

P601 PLUMBING - DETAILS

A101 COMPOSITE FLOOR PLAN - LEVEL 1

A102 COMPOSITE FLOOR PLAN - LEVEL 2

A103 COMPOSITE FLOOR PLAN - LEVEL 3

A201 SECTOR B FLOOR PLAN - LEVEL 1

A202 SECTOR B FLOOR PLAN - LEVEL 2

A203 SECTOR B FLOOR PLAN - LEVEL 3

A401 ENLARGED PLAN - SECULSION ROOM

A402 INTERIOR ELEVATION - LEVEL 1 - SECLUSION ROOM

A403 INTERIOR ELEVATIONS - LEVEL 2 - SECLUSION ROOM

A501 SCHEDULES AND DOOR/FRAME TYPES

A502 DETAILS - WALL FRAMING

A503 DETAILS - FRAMES AND FINISHES

A504 DETAILS - CEILING AND WINDOWS

G000 COVER SHEET - SECLUSION ROOM

G100 VICINITY MAPS, PROJECT INFO, GENERAL NOTES

G101 KEYNOTE MASTER LIST AND ROOM AND ARCHITECTURAL ABBREVIATIONS

G102 ARCHITECTURAL SITE PLAN

SECLUSION ROOM SHEET SCHEDULE

GENERAL SHEETS

ARCHITECTURAL SHEETS

PLUMBING SHEETS

MECHANICAL SHEETS

FIRE PROTECTION SHEETS

ELECTRICAL SHEETS

TELECOMMUNICATION & SECURITY SHEETS

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C

C

C C

C

C

VAN

VAN

VAN

VAN

CP

CP

CP

CP

CP

CP

CP

C P

C P

C P

V A

N

EB

EC

ED

ED

EJ,EJ2,

EJ4

EJ , E

J 2, EJ 4

EC

EC

EE1,E

E2, EG1

EE1,E

E2, EG1

EE1,EE2,

EG1

EE1,EE2,

EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EE 1 ,E

E2 , EG1

EH ,EG

EH , EG

EP 1

,E P2

EP 3

,E P4

EJ ,

E J 2, EJ 4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP1

,E P2

EP3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EJ , E

J 2, EJ 4

EF

EP1

,E P2

EP3

,E P4

EP

,E P2

EP

,E P4

EP

,E P2

EP

,E P4

EP1

,E P2

EP3

,E P4

EJ , E

J 2, EJ 4

EP 1

,E P2

EP 3

,E P4

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2, EP3,EP4,

EP1,E

P2, EP3,E

P4, EP1

,EP2

, EP3

,EP4

EP

1,EP

2, EP

3,EP

4, EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EE1,E

E2, EG1

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1 ,E

P2

EP3 ,E

P4

EP1

,EP2

EP3

,EP4

EP 1

,E P2 , EP 3

,E P4 , E P1 ,E P 2, E P3 ,E P 4, E P1 ,E P2

E P3 ,E P4

E P 1 ,E P2 , E P 3 ,E P4 , EE1

, E

E2, EG1

EE1

, E

E2, EG1

EE1

, E

E2, EG1

EE1

, E

E2, EG1

EE1

, E

E2, EG1

EE1

, E

E2, EG1

EP 1

,E P2

EP 3

,E P4

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

ED

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P 2

EP3

,E P 4

EP1

,E P2

EP3

,E P4

EE

EE

EE

EP1,E

P2

EP3,E

P4

EP1,E

P2

EP3,E

P4

EP 1

,E P2

EP 3

,E P4

EP1

,E P2

EP3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP1

,E P2

EP3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP 1

,E P2

EP 3

,E P4

EP1,E

P2, EP3,E

P4, EP1,E

P2

EP3,E

P4

EJ , E

J 2, EJ 4

EJ,EJ2,

EJ4

GENERAL NOTES

1. INFORMATION OF COMPOSITE SHEETS ARE

FOR REFERENCE ONLY.

2. FOR FURTHER DETAILS SEE SECTOR SHEETS.

D1-A

D1-1

PROPERTY LINE

C O

T T A G

E

C O

T T A G

E

C O

T T A G

E

T R E A T M

E N T M

A L L

G Y M

H O

U S

IN

G

A D

M

IN

IS

T R

A T

IO

N

C U

P

W A R E H O

U S E

D

IN

IN

G

F A

C

IL

IT

Y S

E R

V

IC

E S

A D

M

IS

S

IO

N

A D

M

IN

IS

T R

A T

IO

N

ACCESSIBILITY ROUTE

LEGEND

M E D

L

IN

IC

D R

E A

S W

A Y

PUBLIC ENTRY

SERVICE ENTRY

CONTRACTOR PARKING

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

/1

/2

:2 :3

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

G102

ARCHITECTURAL

SITE PLAN

SCALE: SHEET:1" = 80'-0" G102

ARCHITECTURAL SITE PLAN - ENTRANCES AND PARKING

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

C CCCCCCCC

C CCCCC CC

C C

C C

C C

C

C

V A

N V

A N

VAN

V A

N

CPCP CP CP CP CP CP

C P

C P

C P

VAN

E C

ED

E D

E J ,E J

E J

EJ,EJ2,

EJ4

EC

EC

EE

1,EE

2, EG

EE

,EE

2, EG

E E ,E E

E G

E E ,E E

E G

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EE1 ,EE2,

EG1

EH, EG

EP1,EP2,

EP3,EP4,

E J ,E J

E J

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EJ,EJ2,

EJ4

E F

EP1,EP2,

EP3,EP4,

EP

1, EP

2, EP

3, EP

4, E P ,E P

E P ,E P

E P ,E P

E P ,E P

EJ,EJ2,

EJ4

EP1,EP2,

EP3,EP4,

E P ,E P

E P ,E P

EP

,E P 2, EP

,E P 4, EP

1,E

P2

EP

3,E

P4

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

E P ,E P

E P ,E P

EP

, E P

EP

, E P

EE

,EE

2, EG

EP1,EP

2 , EP3,EP

4 , EP1 ,E P2,

EP3 ,E P4,

EP1,EP2,

EP3,EP4,

EP1,E P2 ,

EP3,E P4 ,

EP1,E P2,EP3,E P4,

EP1,EP2,EP3,EP4,

EP1,EP2,EP3,EP4,

EP1,EP2,

EP3,EP4,

E E ,E E

E G

E E ,E E

E G

E E ,E E

E G

E E ,E E

E G

E E ,E E

E G

E E ,E E

E G

EP1,EP2,

EP3,EP4,

T TT

TT T

T

T

T

T

T

T

T

T

T

T

T

T

T E D

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

E P ,E P

E P ,E P

E P ,E P

E P ,E P

EP

1,E

P2, EP

3,E

P4, EP

1 ,E

P 2

EP

3 ,E

P 4

E E

E E

E E

E P ,E P

E P ,E P

E P ,E P

E P ,E P

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

EP1,EP2,

EP3,EP4,

E P ,E P

E P ,E P

E P ,E P

E P ,E P

EJ,EJ2,

EJ4

C L

C L

CL

C L

CL

CL

C L

CL

CLCL

CLCL CL

CL

C L

C L

CLCL

CL

C L

C L

CL

CL

C L

C L

CL

CL

CL

CL

CL

CL CL

C L

CL

C L

C L

CL

C L

C L

CL

C L

C L

C L

C L

C L

C L

C L

C L

C L

C L

CL

CL

CL

CL

CL

CL

CL CL

CL CL

CL CL

C L

CL

CL CL

CLCL

CL CL CL

C L

C L

C L

CL

CL

C L

CL

CL

C L

C L

CLCL

CL

CL

CLCL

CL

CL CL

C L

C L

CL

CLCL

C L

C L

CL

C L

CL

C L

C L

CL

CL

C

L CL CL

C L

C L

C L

C L

C L

C L

C L

D

ISH

F

LO

W

W ALL

C1

D

DISH

FLOW

LAKE

LOADING DOCK

LAKE

WAREHOUSE

LAKE

VOCATIONAL

LAKE

DINING/FOOD SERVICE

VALLEY

FACILITIES

SERVICES

FOREST QUAD

SRTF COURTYARD

PRAIRIE QUAD

DAYLIGHT COURTYARD

MOUNTAIN QUAD

HOSP COURTYARD

RECREATION FIELD

MOUNTAIN

HOSP HOUSING

FOREST

SRTF HOUSING

TREATMENT MALL

RIVER

MEDICAL CLINIC

VALLEY QUAD

DAYLIGHT COURTYARD

RIVER

ADMITTING

VAN

SALLY PORT

ADMINISTRATION CUPADMINISTRATION/EDD

SERVICE YARD

CUP YARD

COTTAGE 1

RTF

COTTAGE 2

RTF

COTTAGE 3

RTF

E

GYM

SIM.

SIM.

SIM.

SIM.

SIM.

SIM.

SIM.

SIM.

SIM.

PROJECT LOCATION

SERVICE ENTRY

FOR MATERIALS

PUBLIC ENTRY

FOR PERSONNEL

A1

A201

GENERAL NOTES

1. INFORMATION OF COMPOSITE SHEETS ARE

FOR REFERENCE ONLY.

2. FOR FURTHER DETAILS SEE SECTOR SHEETS.

TRAVEL PATH

1. THE HIGHLIGHTED PATHS SIGNIFY WHICH

AREAS ARE ALLOWED FOR TRAVEL TO

PARTICULAR USES BY THE CONTRACTOR.

TRAVLE PATH FOR CONTRACTOR'S

DELIVERIES OF EQUIPMENT AND

MATERIALS

TRAVEL PATH FOR CONTRACTOR'S

PERSONNEL

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :4

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A101

COMPOSITE FLOOR

PLAN - LEVEL 1

SCALE: SHEET:1" = 30'-0" A101

A1

FLOOR PLAN - LEVEL 1 - COMPOSITE PLAN

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

CL

L

C L

CL

C L

CL

C L

CL CL CL

C L

CL

CL

C L

C L

C L

C L

C L

CLCL

CL

CL CL CL CL CL CL CL

C L

CL CL CL

CL

C L

CL

CLCL

CL

C L

CL

LAKE

LOADING DOCK

LAKE

WAREHOUSE

LAKE

VOCATIONAL

LAKE

DINING/FOOD SERVICE

PRAIRIE QUAD

DAYLIGHT COURTYARD

MOUTAIN QUAD

HOSP COURTYARD

MOUNTAIN

HOSP HOUSING

FOREST

SRTF HOUSING

TREATMENT MALL

RIVER

MEDICAL CLINIC

VALLEY QUAD

DAYLIGHT COURTYARD

RIVER

ADMITTING

ADMINISTRATION CUP

FOREST QUAD

SRTF COURTYARD

ROOF

OPEN TO BELOW

ROOF

ROOF

ROOF

ROOF

ADMINISTRATION

MECH ROOM

MECH

WELL

OPEN TO BELOW

MECH WELL

OPEN TO BELOW CUP YARD

SERVICE YARD

ROOF

COTTAGE 1

RTF

COTTAGE 2

RTF

COTTAGE 3

RTF

ROOF

MEZZ

GYM

ROOF

OPEN TO BELOW

PROJECT

LOCATION

A1

A202

GENERAL NOTES

1. INFORMATION OF COMPOSITE SHEETS ARE

FOR REFERENCE ONLY.

2. FOR FURTHER DETAILS SEE SECTOR SHEETS.

TRAVEL PATH

1. THE HIGHLIGHTED PATHS SIGNIFY WHICH

AREAS ARE ALLOWED FOR TRAVEL TO

PARTICULAR USES BY THE CONTRACTOR.

TRAVLE PATH FOR CONTRACTOR'S

DELIVERIES OF EQUIPMENT AND

MATERIALS

TRAVEL PATH FOR CONTRACTOR'S

PERSONNEL

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :4

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A102

COMPOSITE FLOOR

PLAN - LEVEL 2

SCALE: SHEET:1" = 30'-0" A102

A1

FLOOR/ROOF PLAN - LEVEL 2 - COMPOSITE PLAN

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

L

CL

C L

CL

CL

C L

CL CL

CL

C L

C L

C L

C L

C L

C L

CLCL

CL

CL CL CL CL CL CL CL CL

C L

CL CL CL CLC

LCL CL

CLCL

PRAIRIE QUAD

DAYLIGHT COURTYARD

MOUNTAIN

HOSP HOUSING

FOREST

SRTF HOUSING

TREATMENT MALL

VALLEY QUAD

DAYLIGHT COURTYARD

ROOF

ROOF

ROOF ROOF

ROOF

ROOF

FOR REFERENCE NO WORK ON THIS LEVEL

GENERAL NOTES

1. INFORMATION OF COMPOSITE SHEETS ARE

FOR REFERENCE ONLY.

2. FOR FURTHER DETAILS SEE SECTOR SHEETS.

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :5

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A103

COMPOSITE FLOOR

PLAN - LEVEL 3

SCALE: SHEET:1" = 30'-0" A103

A1

FLOOR/ROOF PLAN - COMPOSITE - LEVEL 3

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A2-2 A2-3 A2-4A1-12

A1-A

A1-C

A2-A

A2-B

ABC-5 A2-8

156' - 3"

27' - 9" 13' - 8" 17' - 1 1/2" 9' - 0" 12' - 11 1/2" 19' - 7" 27' - 8" 28' - 6"

FD

FD

P2-1

WHDF

AB-A

AB-A

A2-C

A2-1 A2-6 A2-7

A2-E

A2-F

1/ 4"

/2

/4

PRAIRE QUAD

DAYLIGHT COURTYARD

FOREST QUAD

SRTF COURTYARD

9'

P2-B

P2-A

A-DA-D

EXISTING

FOOTING DRAIN

TO REMAIN

FEC-3

FEC-2

FHV-3

FEC-3

3' -8

/8

A2

A401

TEMPORARY DOOR

AND PARTITION

CONTRACTOR

STAGING ROOM

A1

A401 F1618

ANTE

F1620A

TLT

SHWR

PAT

F1620

SECL

BLINDS

CONTROLS ON

OBSERVATION

SIDE

F1624

PAT SEMI

F1626

PAT SEMI

F1628

TLT

SHWR

PAT

F1622

LNDRY

F1629

PAT SEMI

F1630

TLT TUB

PAT

F1631

COMMON

AREA

F1611

CORR

HOUSING

F1623

PAT SEMI

F1625

PAT SEMI

F1627

PAT SEMI

F1607

EXAM

F1632

MEDS

F1634

PAT BLNG

F1636

STOR

F1648

STOR

OUT

F1638

PAT SEMI

F1637

PAT SEMI

F1639

PAT SEMI

F1641

PAT SEMI

F1640

PAT SEMI

F1643

PAT SEMI

F1645

QUIET

F1644

STAIR

F2-1

F1646

TLT OUT

F1642

STOR

EQUIP

F1605

CHART

F1605A

OFF NS

F1602

ACTIVITY

F1601

ELEC

F1603

STAIR

F1-1

F1606

KIT

F1608

EVS

CLOSET

F1610

SOILED

F1612

CLEAN

F1614

PAT PRVT

ADA

F1600

CORR

HOUSING

A3

A401

F1633

TLT

SHWR

PAT

F1635

TLT

SHWR

PAT

F1616

TLT STF

F1614A

TLT

SHWR

PAT

F1604

PORCH

1. ALL DIMENSIONS ARE TO FACE OF FINISH U.O.N.

2. SEE A501 FOR EXTERIOR WINDOW TREATMENT.

3. ALL DOORS TO MEET ADA CLEARANCE

REQUIREMENTS: 1'-6" @ PULL SIDE AND 1'-0' @

PUSH SIDE OF DOOR, UON.

GENERAL NOTES:

SMOKE RATED WALL

LEGEND

CMU

CONCRETE

WALL TAG

MATCH LINE

INDICATES ITEM ABOVE IN PLAN

S1-G4-XX/XX

NEW WORK

EXISTING TO REMAIN

ELEVATION TAGX#

X#

X#

X#

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :0

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A201

SECTOR B FLOOR

PLAN - LEVEL 1

SCALE: SHEET:1/8" = 1'-0" A201

A1

FLOOR PLAN - LEVEL 1 - SECTOR B

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A1-A

A1-C

A2-A

A2-B

ABC-5 A2-8

27' - 9" 13' - 8" 17' - 1 1/2" 9' - 0" 12' - 11 1/2" 19' - 7" 27' - 8" 28' - 6"

FD

FD

P2-1

AB-A

AB-A

A2-C

A2-1 A2-6 A2-7

A2-E

A2-F

1/ 4"

/2

/4

9'

P2-B

P2-A

A-DA-D

BLINDS

CONTROLS ON

OBSERVATION

SIDE

FEC-3

FEC-2

TEMPORARY

PARTITION

CONTRACTOR

STAGING ROOM

C2

A401

C1

A401

F2620A

TLT

SHWR

PAT

F2614

PAT PRVT

ADA

F2605A

OFF NS

F2618

ANTE

F2623

PAT SEMI

F2644

STAIR

F2-3

F2610

SOILED

F2612

CLEAN

F2624

PAT SEMI

F2605

CHART

F2622

LNDRY

F2606

KIT

F2634

PAT BLNG

F2601

ELEC

F2608

EVS

CLOSET

F2607

EXAM

F2642

STOR

EQUIP

F2625

PAT SEMI

F2626

PAT SEMI

F2627

PAT SEMI

F2638

PAT SEMI

F2640

PAT SEMI

F2639

PAT SEMI

F2633

TLT

SHWR

PAT

F2635

TLT

SHWR

PAT

F2641

PAT SEMI

F2630

TLT TUB

PAT

F2637

PAT SEMI

F2645

QUIET

F2629

PAT SEMI

F2643

PAT SEMI

F2603

STAIR

F1-3

F2611

CORR

HOUSING

F2628

TLT

SHWR

PAT

F2616

TLT STF

F2636

STOR

F2620

SECL

F2631

COMMON

AREA

F2600

CORR

HOUSING

F2614A

TLT

SHWR

PAT

F2632

MEDS

F2604

PORCH

C3

A401

1. ALL DIMENSIONS ARE TO FACE OF FINISH U.O.N.

2. SEE A501 FOR EXTERIOR WINDOW TREATMENT.

3. ALL DOORS TO MEET ADA CLEARANCE

REQUIREMENTS: 1'-6" @ PULL SIDE AND 1'-0' @

PUSH SIDE OF DOOR, UON.

GENERAL NOTES:

SMOKE RATED WALL

LEGEND

CMU

CONCRETE

WALL TAG

MATCH LINE

INDICATES ITEM ABOVE IN PLAN

S1-G4-XX/XX

NEW WORK

EXISTING TO REMAIN

ELEVATION TAGX#

X#

X#

X#

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :0

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A202

SECTOR B FLOOR

PLAN - LEVEL 2

SCALE: SHEET:1/8" = 1'-0" A202

A1

FLOOR PLAN - LEVEL 2 - SECTOR B

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A2-A

A2-B

ABC-5 A2-8

156' - 3"

27' - 9" 13' - 8" 17' - 1 1/2" 9' - 0" 12' - 11 1/2" 19' - 7" 27' - 8" 28' - 6"

FD

FD

P2-1

AB-A

A2-C

A2-1 A2-6 A2-7

A2-E

A2-F

1/ 4"

/2

/4

9'

P2-B

P2-A

A-D

FEC-3

FEC-2

F3620A

TLT

SHWR

PAT

F3618

ANTE

F3620

SECL

FOR REFERENCE ONLY:

NEW WORK IS TO MATCH

EXISTING CONDITIONS

ON THE THIRD FLOOR

F3632

MEDS

F3623

PAT SEMI

F3625

PAT SEMI

F3624

PAT SEMI

F3626

PAT SEMI

F3627

PAT SEMI

F3629

PAT SEMI

F3628

TLT

SHWR

PAT

F3630

TLT TUB

PAT

F3611

CORR

HOUSING

F3622

LNDRY

F3633

TLT

SHWR

PAT

F3635

TLT

SHWR

PAT

F3637

PAT SEMI

F3638

PAT SEMI

F3636

STOR

F3644

STAIR

F2-3

F3642

STOR

EQUIP

F3640

PAT SEMI

F3639

PAT SEMI

F3641

PAT SEMI

F3643

PAT SEMI

F3645

QUIET

F3600

CORR

HOUSING

F3607

EXAM

F3605

CHART

F3605A

OFF NS

F3601

ELEC

F3614A

TLT

SHWR

PAT

F3616

TLT STF

F3614

PAT PRVT

ADA

F3612

CLEAN

F3610

SOILED

F3608

EVS

CLOSET

F3606

KIT

F3604

PORCH

F3631

COMMON

AREA

F3634

PAT BLNG

F3603

STAIR

F1-3

1. ALL DIMENSIONS ARE TO FACE OF FINISH U.O.N.

2. SEE A501 FOR EXTERIOR WINDOW TREATMENT.

3. ALL DOORS TO MEET ADA CLEARANCE

REQUIREMENTS: 1'-6" @ PULL SIDE AND 1'-0' @

PUSH SIDE OF DOOR, UON.

GENERAL NOTES:

SMOKE RATED WALL

LEGEND

CMU

CONCRETE

WALL TAG

MATCH LINE

INDICATES ITEM ABOVE IN PLAN

S1-G4-XX/XX

NEW WORK

EXISTING TO REMAIN

ELEVATION TAGX#

X#

X#

X#

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :1

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A203

SECTOR B FLOOR

PLAN - LEVEL 3

SCALE: SHEET:1/8" = 1'-0" A203

A1

Floor Plan - Level 3 - Sector B

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

S

S

F

C

N

S

F

F

S

S

S

S

S

F

F

A2-2 A2-3 A2-4

A2-EA2-E

A-D

F1620

SECL

F1620A

TLT

SHWR

PAT

F1618

ANTE

F

F1620A F1618A

G4-CDE4-CD

S-A4-A/DC

A4-AA/CB

G4-BD

F i N W2

F1614

PAT PRVT

ADA

F1600

CORR

HOUSING

A402

B2

A402A1

A402

D2

A402

C1

C2

C3

C4

D4

D1D3

A4

A5

B4

B1B3

8'

/8

7'

5/ 8"

/8

1'

/8

5' - 4 1/2" 7" 3' - 7" 6' - 11 7/8" 9' - 0"

G4-A

G4-A i N W2

INFILL EXISTING OPENING

WITH NEW WALL AT

REMOVED WINDOW

A4-BC/DC

G4-BD

G4-B

A4-B/C

3 1/8"

G4-C

A4-C/DC

T8

E4-A

A2-2 A2-3 A2-4

A2-EA2-E

A-D

F2620

SECL

F2620A

TLT

SHWR

PAT

F2618

ANTE

F

F2618AF2620A

i N W2

E 4-

C D

G 4-

C D

S-A4-A/DC

A4-C/DC

F

A4-AA/CB

F2614

PAT PRVT

ADA

F2612

CLEAN

F2600

CORR

HOUSING

F2616

TLT STF

F2614A

TLT

SHWR

PAT

A403A1

A403

B2

A403

C3

A403D3

B1

B4

B3

C1

C2 C4

D2

D1

A5

A4

D4

G4-A

G4-A

5' - 4 1/2" 7" 3' - 7" 6' - 11 7/8"

1'

/8

8'

/4 i N W2

G4-BD

G4-BD

G4-C

A4-B/C

A4-BC/DC

G4-B

A4-A/DC

3 5/8"

INFILL EXISTING OPENING

WITH NEW WALL AT

REMOVED WINDOW

T8

A501 A1

A501 A1

A2-2 A2-3 A2-4

A2-EA2-E

A-D

F1618

ANTE

F1620

SECLQUIET LG

OBSERVATION

F1614

PAT PRVT

ADA

F1600

CORR

HOUSING

REMOVE WALL, TYPICAL

REMOVE WINDOW, TYPICAL

REMOVE WALL BOARD

TO FACE OF STUDS,

TYPICAL

REMOVE DOOR

REMOVE FLOORING,

REMOVE CEILING

REMOVE FLOORING,

REMOVE CEILING

TEMPORARY

PARTITION IN PLACE

PRIOR TO DEMOLITION

TEMPORARY

PARTITION IN PLACE

PRIOR TO DEMOLITION

A2-2 A2-3 A2-4

A2-EA2-E

A-D

F2620

SECL

F2618

ANTE

F2600

CORR

HOUSING

F2616

TLT STF

F2614A

TLT

SHWR

PAT

F2614

PAT PRVT

ADA

F2612

CLEAN

QUIET LG

OBSERVATION

REMOVE WALL, TYPICAL

REMOVE WINDOW, TYPICAL

REMOVE WALL BOARD

TO FACE OF STUDS,

TYPICAL

REMOVE DOOR

REMOVE FLOORING,

REMOVE CEILING

REMOVE FLOORING,

REMOVE CEILING

TEMPORARY

PARTITION IN PLACE

PRIOR TO DEMOLITION

TEMPORARY

PARTITION IN PLACE

PRIOR TO DEMOLITION

EXISTING TO REMAIN

EXISTING

DEMOLISHED

NEW

TEMPORARY

NEW

CONSTRUCTION

A2-2 A2-3

A2-EA2-E

9' - 0"

9' - 0" 9' - 0"

F1620

SECL

F1620A

TLT

SHWR

PAT

F1618

ANTE

F1600

CORR

HOUSING

3' - 8 3/8" 8' - 0" 4' - 8 3/4"

3' - 2 5/8" 5' - 10 1/4" 2' - 1 7/8" 5' - 3 3/8"

5'

/4

4'

/4

4'

2'

7/ 8"

A2-2 A2-3

A2-EA2-E

A-D

9' - 0"

9' - 0"

9' - 0"

4' - 4 3/8" 8' - 0 7/8" 4' - 8 1/8"

3'

/8

4'

4'

/4

5'

/4

4' - 7 3/4" 5' - 0 5/8" 2' - 10 3/4" 4' - 6 1/8"

F2620

SECL

F2620A

TLT

SHWR

PAT

F2618

ANTE

F2600

CORR

HOUSING

PARTITION (AS INDICATED ON FLOOR PLANS)

FIRE RATING INDICATION

PARTITION TYPE

MET STUD/ CMU WIDTH/ CAVITY WIDTH FOR CHASE WALL

PARTITION TYPE MODIFIER, GYP TYPE, OUTER LAYER TAG SIDE

2A3-XX/XX

PARTITION TYPE MODIFIERS:

THE FOLLOWING NOTES APPLY TO THE FULL EXTENT OF EACH PARTN,

WHERE "PARTN TYPE MODIFIER" CHARACTER(S) ARE SHOWN ON THE WALL

TAG:

A. GYP WALL BOARD

B. WATER RESISTANT GYP WALL BOARD

C. FIBER REINFORCED IMPACT RESISTANT GYP WALL BOARD

D. 1/2" PLYWOOD SHEATHING UP TO CEILING

E. 1 1/8" RESILIENT SOUND ISOLATION CLIP

F. CONCRETE MASONRY UNIT

G. 1" GYP SHAFT LINER PANEL

PARTITION TYPE MODIFIER, GYP TYPE, INNER LAYER TAG SIDE

PARTITION TYPE MODIFIER, GYP TYPE, INNER LAYER OPPOSITE TAG SIDE

PARTITION TYPE MODIFIER, GYP TYPE, OUTER LAYER OPPOSITE TAG SIDE

PARTITION TYPE MODIFIER, INSULATION, / = BATT INSULATION % = NO BATT INSULATION

PARTITION TYPE TAG:

1.ITEMS SHOWN TO REMAIN OR TO BE RELOCATED

SHALL BE PROTECTED AT ALL TIMES. ANY EXISTING

MATERIALS DAMAGED BY DEMOLITION, REGARDLESS OF

PROTECTION, SHALL BE REPAIRED AS REQUIRED TO

MATCH QUALITY OF UNDAMAGED ADJACENT SURFACES.

2.WHERE WALLS ARE SHOWN TO BE REMOVED, THEY

ARE TO BE REMOVED IN THEIR ENTIRETY.

3.REFERENCE PD200-SERIES DRAWINGS FOR PLUMBING-

RELATED DEMOLITION AND REQUIREMENTS.

4.REFERENCE ED200-SERIES DRAWINGS FOR

ELECTRICAL POWER, LIGHTING AND SIGNAL DEVICE

DEMOLITION AND REQUIREMENTS.

5.REFERENCE MD200-SERIES DRAWINGS FOR

MECHANICAL EQUIPMENT, DUCTWORK, SUPPORT AND

BRACING DEMOLITION AND REQUIREMENTS.

6.MAINTAIN EXISTING FIRE PROTECTION LATERAL AND

SPRINKLER HEADS DURING CONSTRUCTION.

7.DEMOLITION PLAN PROVIDES GENERAL SCOPE AND

BASIC INSTRUCTION FOR CONTRACTOR USE IN

CONJUNCTION WITH BALANCE OF CONTRACT

DOCUMENTS AND PRE-BID JOB SITE SURVEY OF

EXISTING CONDITIONS, WORK AREA AND SCOPE IN

BIDDING AND BUILDING THE PROJECT.

8.ALL REQUIRED DEMOLITION WORK SHALL BE INCLUDED

IN THE BASE BID PACKAGE SUBMITTED BY THE

CONTRACTOR.

9.CONTRACTOR MUST TAKE ALL NECESSARY

PRECAUTIONS TO ENSURE THE SAFETY OF HOSPITAL

STAFF AND PATIENTS, PUBLIC AND WORKMEN WITHIN

AND ADJACENT TO THE DEMOLITION AREA AND WORK

SITE TO PREVENT ACCIDENT OR INJURY. CONTRACTOR

SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES

AND REGULATIONS PERTAINING TO SAFETY AND

ACCIDENT PREVENTION.

10.REMOVE DEMOLITION MATERIALS AND REFUSE AS

WORK PROGRESSES TO PREVENT ACCUMULATION OF

DEBRIS, BUT NOT LESS THAN DAILY.

11.FULLY ENCLOSE DEMOLITION WORK AREA WITH

DEMOUNTABLE PARTITION PROTECTION TO SEAL OFF

ADJACENT AREAS FROM PARTICULATES, DUST AND

DEBRIS. DO NOT OPERATE MECHANICAL VENTILATION

EQUIPMENT DURING DEMOLITION WORK IN A MANNER

THAT WOULD INTRODUCE DUST INTO THE SYSTEM. DO

NOT OPERATE SUPPLEMENTAL MECHANICAL

VENTILATION EQUIPMENT WITHOUT REQUIRED FILTERS

OR WITH CLOGGED FILTERS.

12.DO NOT DISRUPT UTILITIES TO OTHER AREAS

WITHOUT OWNER’S FULL, ADVANCE KNOWLEDGE AND

CONSENT AND ONLY AS DIRECTED BY THE OWNER’S

REPRESENTATIVE.

13.DO NOT DISRUPT UTILITIES WHICH WOULD AFFECT

THE FIRE ALARM, FIRE PROTECTION OR LIFE SAFETY

SYSTEMS WITHOUT FULL KNOWLEDGE OF AND

DIRECTION FROM THE LOCAL GOVERNING AUTHORITIES

(AHJ).

14.CONTRACTOR SHALL MAINTAIN ADEQUATE SUPPORT,

SECURITY, ALARM AND EMERGENCY LIGHTING TO ALL

EXISTING ITEMS TO REMAIN.

15.CONTRACTOR SHALL IMMEDIATELY NOTIFY THE

OWNER’S REPRESENTATIVE SHOULD ANY EXISTING

CONDITION BE DISCOVERED DURING DEMOLITION THAT

COULD IMPACT PROJECT SCHEDULE OR EFFECT THE

TIMELY COMPLETION OF THE REMAINING WORK.

GENERAL NOTES:

DEMO PLAN

GENERAL NOTES

1. REFER TO SHEET G101 FOR ABBREVIATION

DESIGNATION

2. FOR DOOR & SIDELIGHT TYPES, SIZES &

FINISHES, REFER TO DOOR SCHEDULE.

4. REFER TO FLOOR FINISH PLANS AND FINISH

SCHEDULE WHERE APPLICABLE.

5. DOORS AND SIDELITES SHOWN FOR

REFERENCE ONLY, SEE FLOOR PLANS AND

DOOR AND FRAME SCHEDULE FOR TYPES,

SIZES & FINISHES.

6. REFER TO REFLECTED CEILING PLANS FOR

LIGHTING LOCATIONS. FOR LIGHTING TYPES,

REFER TO ELECTRICAL LIGHTING PLANS.

7. EQUIPMENT SHOWN AS OFOI AND OFCI ARE

FOR REFERENCE ONLY. CONTRACTOR TO

COORDINATE MECHANICAL ELECTRICAL AND

PLUMBING AS REQUIRED.

8. REFER TO REFLECTED CEILING PLANS FOR

CURTAIN TRACK LOCATIONS.

9. REFER TO FINISH SCHEDULES FOR FINISHES,

TYP. UON

LEGEND

GYPSUM BOARD CEILING

CEILING HEIGHT ABOVE

FINISHED FLOOR

OPEN TO STRUCTURE

9'-0"

2'x4' ACOUSTIC

CEILING PANELS

HORIZONTAL SHAFT WALL , 1 HR

RATED ASSEMBLY

GYPSUM BOARD ON

PLYWOOD CEILING

XX

X

FINISH DESIGNATION

F S S

MECHANICAL FIXTURES,

SEE MECHANICAL

LIGHTING FIXTURES,

SEE ELECTRICAL

EXIT SIGN, SEE

ELECTRICAL

COMMUNICATION

DEVICES, SEE TELECOM

F

C

SPPN

FIRE ALARM / SENSORS,

SEE ELECTRICAL

CUBICLE CURTAIN

SPRINKLER

CEILING MOUNTED

TELECOMMUNICATION

OUTLET IS "ABOVE CEILING"

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :2

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A401

ENLARGED PLAN -

SECULSION ROOM

SCALE: SHEET:1/4" = 1'-0" A401

A2

ENLARGED FLOOR PLAN - LEVEL 1

SCALE: SHEET:1/4" = 1'-0" A401

C2

ENLARGED FLOOR PLAN - LEVEL 2

SCALE: SHEET:1/4" = 1'-0" A401

A1

ENLARGED DEMOLITION PLAN - LEVEL 1

SCALE: SHEET:1/4" = 1'-0" A401

C1

ENLARGED DEMOLITION FLOOR PLAN - LEVEL 2

LEGEND - FLOOR PLAN

SCALE: SHEET:1/4" = 1'-0" A401

A3

ENLARGED RCP - LEVEL 1 - SECTOR B - SECLUSION RM

SCALE: SHEET:1/4" = 1'-0" A401

C3

ENLARGED RCP - LEVEL 2 - SECTOR B - SECLUSION RM

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A2-3

WINDOW

BASE: WB-1

WALL FINISH: PW-1

WALL FINISH: P-3

6'

SH-1H, BARRIER FREE PATIENT

SHOWER

PLUMBING FIXTURES SEE PLUMBING

D2

A503

D4

A503

C4

A503

BASE: INTEGRAL/6"

C3

A503

BASE: INTEGRAL/6"

WALL FINISH: P-3

D4

A503

4' - 6"

PLUMBING FIXTURES SEE PLUMBING

RECESSED SHELF

PLUMBING FIXTURES SEE PLUMBING

SHOWER CUBICLE CURTAIN

SH-1H, BARRIER FREE PATIENT

SHOWER

3'

WALL FINISH: P-3

INTEGRAL/6"

PLUMBING FIXTURES SEE PLUMBING

EXISTING WINDOW W/

NEW WALL INFILL

SEE WALL TYPE

ON FLOOR PLAN

42" GRAB BAR

18" GRAB BAR

1' - 0"

3' - 4"

2'

0"

6"

SECURITY CAMERA

A2-9 A2-EA2-10 A2-CA2-EA2-F A-D

REPAIR EXISING WALL WHEN TEMPORARY PARTITION REMOVED

NEW PAINT FULL LENGTH OF WALL, EACH SIDE OF CORRIDOR

4' - 3"

5'-11"

EXISTING CEILING TO REMAIN

NEW DOOR

SEE SCHED

WALL FINISH: P-1

NEW WALL INFILL

SEE WALL TYPE

ON FLOOR PLAN

A2-3 A2-4

WALL FINISH: P-1

BASE: RB-1

A2-3A2-4

WALL FINISH: P-1

BASE: RB-1

A2-3

BASE: RB-1

WALL FINISH: P-2

6' - 1 1/2"

DOMESTIC AND

FIRE SHUT OFF

VALVE BOX, SEE

PLUMBING

DRAWINGS

PLUMBING FIXTURES SEE PLUMBING

3' - 6"

2' - 3"

GLOVE BOX, OFOI

PERSONAL

PROTECTIVE BOX,

OFOI

2' - 0"

4'

WALL FINISH:

P-3

WINDOW

BASE: RB-1

COUNTERTOP

3'

1' - 0"

6"

2'

PLUMBING FIXTURES SEE PLUMBING

SOAP DISP

PAPER TOWEL DISP

D1

A503

A2-3

WALL FINISH: P-2

WINDOW

BASE: RB-1

FLOATING

COUNTERTOP

SECURTIY CAMERA

BASE: RB-1

WALL FINISH: P-2

BASE: WB-1

WALL FINISH: PW-1

EXISTING WINDOW

NEW SECURITY CAMERA

BASE: WB-1

WALL FINISH: PW-1

BASE: WB-1

WALL FINISH: PW-1

WALL FINISH:P-3

BASE:

INTEGRAL/6"

D3

A503

1' - 0"

PLUMBING FIXTURES SEE PLUMBING

SH-1H, BARRIER FREE PATIENT

SHOWER

AUTO RELEASE CLOTHES HOOKS

PANEL

1. SEE SHEET G101 FOR ABBREVIATION

DESIGNATION

2. SEE REFLECTED CEILING PLANS FOR

LIGHTING LOCATIONS. FOR LIGHTING TYPES,

SEE ELECTRICAL LIGHTING PLANS AND

SPECS.

3. EQUIPMENT SHOWN AS OFOI ARE

FOR REFERENCE ONLY. CONTRACTOR TO

PROVIDE BACKING FOR WALL MOUNTED

EQUIPMENT.

4. SEE A504 FOR TYPICAL WALL BASE DETAILS.

ALL DETAILS ARE APPLICABLE WHETHER OR

NOT KEYED ON PLAN.

5. SEE A504 FOR INFORMATION ON INTERIOR

WINDOW TYPES.

6. ALL SINKS TO RECEIVE SOAP AND PAPER

TOWEL DISPENSER. FOR LOCATION AND

MOUNTING HEIGHTS SEE A401, A402& A403

GENERAL NOTES:

INTERIOR ELEVATION

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :4

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A402

INTERIOR

ELEVATION - LEVEL 1

- SECLUSION ROOM

SCALE: SHEET:1/4" = 1'-0" A402

B2

INTERIOR ELEVATION - SECLUSION RM - SOUTH

SCALE: SHEET:1/4" = 1'-0" A402

C2

INTERIOR ELEVATION - TLT SHWR PAT - EAST

SCALE: SHEET:1/4" = 1'-0" A402

C3

INTERIOR ELEVATION - TLT SHWR PAT - SOUTH

SCALE: SHEET:1/4" = 1'-0" A402

C4

INTERIOR ELEVATION - TLT SHWR PAT - WEST

SCALE: SHEET:1/4" = 1'-0" A402

A1

INTERIOR ELEVATION - HOUSING CORRIDOR - WEST

SCALE: SHEET:1/4" = 1'-0" A402

A4

INT. ELEV. - HOUSING CORRIDOR - NORTH

SCALE: SHEET:1/4" = 1'-0" A402

A5

INT. ELEV. - HOUSING CORRIDOR - SOUTH

SCALE: SHEET:1/4" = 1'-0" A402

D2

INTERIOR ELEVATION - ANTE RM - SOUTH

SCALE: SHEET:1/4" = 1'-0" A402

D3

INTERIOR ELEVATION - ANTE RM - WEST

SCALE: SHEET:1/4" = 1'-0" A402

D4

INTERIOR ELEVATION - ANTE RM - NORTH

SCALE: SHEET:1/4" = 1'-0" A402

D1

INTERIOR ELEVATION - ANTE RM - EAST

SCALE: SHEET:1/4" = 1'-0" A402

B3

INTERIOR ELEVATION - SECLUSION RM - WEST

SCALE: SHEET:1/4" = 1'-0" A402

B4

INTERIOR ELEVATION - SECLUSION RM - NORTH

SCALE: SHEET:1/4" = 1'-0" A402

B1

INTERIOR ELEVATION - SECLUSION RM - EAST

SCALE: SHEET:1/4" = 1'-0" A402

C1

INTERIOR ELEVATION - TLT SHWR PAT - NORTH

NUMBER DESCRIPTION DATE

R

EG

IS

TERED ARCHITEC

T

STATE OF OREGON

BJORN

CLOUTEN

PORTLAND, OR

R

E C

O V

E R

Y W

A2-9 A2-EA2-10 A2-EA2-F A-D

93' - 2 3/8"

WALL FINISH: P-1

EXISTING CEILING TO REMAIN

REPAIR EXISTING WALL WITH TEMPORARY PARTITION

NEW WALL INFILL

SEE WALL TYPE

ON FLOOR PLAN

NEW DOOR

SEE SCHED

BASE: RB-1

WALL FINISH:

P-2

TEMPORARY

DOOR

A2-3

BASE: RB-1

WALL FINISH:

P-2

TEMPORARY

DOOR

A2-3

BASE: WB-1

WALL FINISH: PW-1

BASE: WB-1

WALL FINISH:

PW-1

A2-2A2-3

WALL FINISH:

PW-1

WINDOW

BASE: WB-1

NEW

SECURITY

CAMERA

BASE: WB-1

WALL FINISH: PW-1

EXISTING WINDOW

SECURITY CAMERA

BASE:

INEGRAL/6"

WALL FINISH:

P-3

D4

A503

PLUMBING FIXTURES SEE PLUMBING

3'

SH-1H, BARRIER FREE PATIENT

SHOWER

PLUMBING FIXTURES SEE PLUMBING

SHOWER CUBICLE CURTAIN

RECESSED SHELF4' - 6"

EXISTING WINDOW

W/NEW WALL INFILL

SEE WALL TYPE

ON FLOOR PLAN

WALL

FINISH: P-3

BASE:

INTEGRAL/6"

PLUMBING FIXTURES SEE PLUMBING

SECURITY CAMERA

1' - 0" 42" GRAB BAR

2'

0"

6"

18" GRAB BAR3' - 4"

A2-2

WALL FINISH: P-3

BASE: INTEGRAL/6"

PLUMBING FIXTURES SEE PLUMBING

SH-1H, BARRIER FREE PATIENT

SHOWER

SHOWER CUBICLE CURTAIN

SECURITY CAMERA

1' - 0" AUTO RELEASE CLOTHES HOOK

TOILET

SHOWER

WALL FINISH:

P-3

BASE: INTEGRAL/6"

C3

A503

C4

A503

PLUMBING FIXTURES SEE PLUMBING

PLUMBING FIXTURES SEE PLUMBING

SHOWER CUBICLE CURTAIN

D4

A503

WALL FINISH: P-3

BASE: RB-1

FLOATING

COUNTERTOP

2'

WINDOW

4'

/4

3'

2' - 1"

3' - 2"

3'

1"

PLUMBING FIXTURES SEE PLUMBING

SOAP DISP, OFCI

PAPER TOWEL

DISP, OFCI

D1

A503

A2-3

2'

BASE: RB-1

WALL FINISH: P-2

FLOATING

COUNTERTOP

WINDOW

WALL FINISH:

P-2

BASE: RB-1

EXISTING DOOR

A2-3

BASE: RB-1

SINK

4'

2' - 0"

GLOVE BOX, OFOI

PERSONAL

PROTECTIVE BOX,

OFOI

DOMESTIC AND

FIRE SHUT OFF

VALVE BOX, SEE

PLUMBING

DRAWINGS

WALL FINISH: P-2

2' - 3"

3' - 6"

1. SEE SHEET G101 FOR ABBREVIATION

DESIGNATION

2. SEE REFLECTED CEILING PLANS FOR

LIGHTING LOCATIONS. FOR LIGHTING TYPES,

SEE ELECTRICAL LIGHTING PLANS AND

SPECS.

3. EQUIPMENT SHOWN AS OFOI ARE

FOR REFERENCE ONLY. CONTRACTOR TO

PROVIDE BACKING FOR WALL MOUNTED

EQUIPMENT.

4. SEE A504 FOR TYPICAL WALL BASE DETAILS.

ALL DETAILS ARE APPLICABLE WHETHER OR

NOT KEYED ON PLAN.

5. SEE A504 FOR INFORMATION ON INTERIOR

WINDOW TYPES.

6. ALL SINKS TO RECEIVE SOAP AND PAPER

TOWEL DISPENSER. FOR LOCATION AND

MOUNTING HEIGHTS SEE A401, A402& A403

GENERAL NOTES:

INTERIOR ELEVATION

1 2 3 4 5

A

B

C

D

E

DRAWING TITLE

REVISIONS

DRAWN BY

CHECKED BY

DRAWING NO

CONSULTANT PROJECT NO

OWNER PROJECT NO

PROJECT NO

DATE

DRAWING SCALES

INDICATED APPLY TO 30"

X 42" DRAWING SHEETS.

SCALE MAY NOT BE

ACCURATE IF DRAWING

PLOTS ARE LESS THAN

THIS SIZE.

TRUE NORTH

PROJECT NORTH

/1

/2

:2 :5

P

M

100% CONSTRUCTION

DOCUMENTS

S E

C L

U S

IO

N

R O

O M

R E

N O

V A

T

IO

N

O R

E G

O N

S T

A T

E H

O S

P

IT

A L

J U

N C

T

IO

N C

IT

Y

D

R E

A S

W A

Y

J U

N C

T

IO

N C

IT

Y

O

R

221012

September 15, 2022

JD

JM

A403

INTERIOR

ELEVATIONS - LEVEL

2 - SECLUSION ROOM

SCALE: SHEET:1/4" = 1'-0" A403

A1

INTERIOR ELEVATION - HOUSING CORRIDOR - WEST

SCALE: SHEET:1/4" = 1'-0" A403

A4

INT. ELEV. - HOUSING CORRIDOR - NORTH

SCALE: SHEET:1/4" = 1'-0" A403

A5

INT. ELEV. - HOUSING CORRIDOR - SOUTH

SCALE: SHEET:1/4" = 1'-0" A403

B2

INTERIOR ELEVATION - SECLUSION RM - NORTH

SCALE: SHEET:1/4" = 1'-0" A403

B1

INTERIOR ELEVATION - SECLUSION RM EAST

SCALE: SHEET:1/4" = 1'-0" A403

B4

INTERIOR ELEVATION - SECLUSION RM - SOUTH

SCALE: SHEET:1/4" = 1'-0" A403

B3

INTERIOR ELEVATION - SECLUSION RM - WEST

SCALE: SHEET:1/4" = 1'-0" A403

C3

INTERIOR ELEVATION - TLT SHWR PAT - SOUTH

SCALE: SHEET:1/4" = 1'-0" A403

C2

INTERIOR ELEVATION - TLT SHWR PAT - WEST

SCALE: SHEET:1/4" = 1'-0" A403

C1

INTERIOR ELEVATION - TLT SHWR PAT - NORTH

SCALE: SHEET:1/4" = 1'-0" A403

C4

INTERIOR ELEVATION - TLT SHWR PAT - EAST

SCALE: SHEET:1/4" = 1'-0" A403

D3

INTERIOR ELEVATION - ANTE RM - WEST

SCALE: SHEET:1/4" = 1'-0" A403

D2

INTERIOR ELEVATION - ANTE RM - NORTH

SCALE:…

This is the start of the file's text. The full file is on GovTribe.