Attachment B.1 - PRIMARY CARE BLDG Drawings.pdf
PDF 36 MB Posted
- Attached to
- Y1DA--Construct Primary Care at VANCHCS, Mather Campus Federal contract opportunity
- Solicitation number
- 36C26119B0014
About this file
This document provides details for a federal contract solicitation to construct a primary care building. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 is seeking a single contractor to complete a new 14,857 square foot primary care facility at the VA Northern California Healthcare System campus in Mather, California for between $5-10 million. Interested parties must be a general construction company with an NAICS code of 236220 and able to provide 100% performance and payment bonds. The project has a 425 day period of performance from notice to proceed. This opportunity is reserved as a 100% set-aside for service-disabled veteran-owned small businesses who must be verified and listed in the Vendor Information Pages. The solicitation will be issued through beta.sam.gov and all questions and amendments will be posted there. The pre-solicitation notice was released on May 27, 2020.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1713192531374349
2814202632384450
3915212733394551
41016222834404652
51117232935414753
61218243036424854
273951
1622284052
18424854
DETAILS ARE NUMBERED ACCORDING TO
THEIR LOCATION ON EACH SHEET AND
ARE NOT NUMBERED CONSECUTIVELY.
EACH MODULE MAINTAINS THE NUMBER
ASSOCIATED WITH IT
THIS SYSTEM CAN BE APPLIED TO ANY
DRAWING THAT CONTAINS MULTIPLE
IMAGES. THE IMAGES ARE NUMBERED
ACCORDING TO THE MODULE SYSTEM
SHOWN ILLUSTRATED TO THE LEFT
EACH DETAIL MAY OCCUPY ONE OR MORE
WHOLE MODULES. THE DETAIL MODULE IS
USED TO ESTABLISH THE IDENTIFYING
LABEL FOR EACH DETAIL, NOT TO LIMIT
THE SIZE OF THE DETAIL
DETAIL MODULE LAYOUT
THE NUMBER OF THE MODULE WHICH
OCCURS IN THE LOWER LEFT CORNER
OF A SINGLE MODULE OR SEVERAL
MODULES GROUPED TOGETHER WILL
DEFINE THE FINAL DETAIL NUMBER AS
SHOWN IN THE ILLUSTRATION TO THE
LEFT. ALTHOUGH THE MODULE
NUMBERS OCCUR IN CONSECUTIVE
ORDER, NOT ALL NUMBERS ARE
NECESSARILY USED ON EACH SHEET
DETAIL NUMBERING EXAMPLE
CONSULTANT
ADVANCE DESIGN CONSULTANTS, INC.
RATCLIFF
BKF
SMITH & SMITH
BIGGS CARDOSA ASSOCIATES INC.
ADVANCE DESIGN CONSULTANTS, INC.
BJL ENTERPRISES LLC
MECHANICAL, ELECTRICAL AND PLUMBING
ARCHITECTURAL
CIVIL
LANDSCAPE ARCHITECTS
STRUCTURAL ENGINEERS
FIRE PROTECTION
TELECOMMUNICATIONS
998 PARK AVE.
SAN JOSE, CA 95126
5856 DOYLE STREET
EMERYVILLE, CA 94608
980 9TH STREET
SACRAMENTO, CA 95814
1501 NORTH POINT STREET
SAN FRANCISCO, CA 94123
805 THE ALAMEDA
SAN JOSE, CA 95126
998 PARK AVE.
SAN JOSE, CA 95126
39 CALIFORNIA AVE., #202
PLEASANTON, CA 94566
DISCIPLINE ADDRESS
CONSULTANT INFORMATIONDESIGN APPROVAL
138 CHIEF ENGINEER
BUILDING SERVICE REPRESENTATIVE
001/ SVD ASSOCIATE DIRECTOR
001/EBD ASSOCIATE DIRECTOR
118 ASSOCIATE DIRECTOR/ NURSING
11 CHIEF OF STAFF
00 DIRECTOR
DATE
DATE
DATE
DATE
DATE
DATE
DATE
on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot
6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot
6"
6"
6"
1 2 3 4 5 6
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
7 8 9
VA FORM 08-6231, OCT 1978
Date
Approved: Project Director
Drawing Title: Project Title:
Location
Project Number:
Building Number:
Drawing Number:
Checked Drawn
ARCHITECT/ENGINEERS
STAMP
Office of Facilities
Management
Dwg. of
ONLY WET SIGNED DOCUMENTS CONSTITUTE ADVANCE DESIGN CONSULTANTS, INC.
PROFESSIONAL WORK AND BECAUSE OTHER REPRODUCIBLE DOCUMENTS MAY BE
EASILY ALTERED WITHOUT THE CONSENT OF ADVANCE DESIGN CONSULTANTS, INC.,
THE WET SIGNED DOCUMENTS MUST BE REFERRED TO FOR THE ORIGINAL AND
CORRECT INFORMATION. IF THERE ARE ANY DIFFERENCES BETWEEN THE WET
SIGNED DOCUMENTS AND ANY OTHER DOCUMENTS, THE WET SIGNED DOCUMENTS
SHALL GOVERN.
ADVANCE DESIGN CONSULTANTS, INC. IS NOT RESPONSIBLE FOR ANY
MODIFICATIONS MADE TO OUR DOCUMENTS BY ANYONE OTHER THAN AUTHORIZED
REPRESENTATIVES OF ADVANCE DESIGN CONSULTANTS, INC.
PO# 13-308-39
ATTENTION:
KEY PLANCONSULTANTS:
95% CONSTRUCTION DOCUMENTS (14-272) 11/7/17
5/4/18
1 9 A
G
FINAL ISSUE FOR BID
FINAL BID DOCUMENTS (14-273) 3/9/18
FINAL ISSUE FOR BID (14-276) 5/4/18
D:
\R ev itL oc als
\A
9_
Pr im ar yC ar e_
CO
NT
AI
NE
R1 7_ do lse n@ ra tcl iffa rch .co m.
rvt
5/4/2018 11:55:48 AM
GI0.00
COVER SHEET & PROJECT TEAM CONSTRUCT PRIMARY CARE SERVICES
BLDG.
612-400
10535 HOSPITAL WAY MATHER, CA.
VICINITY MAP
VETERANS AFFAIRS NORTHERN
CALIFORINA HEALTHCARE SYSTEM
VA PROJECT NO. 612-400
APPROVALS CAMPUS MAP
PROJECT AREA
PARKING STRUCTURE
700649
CONSTRUCT PRIMARY CARE
SERVICES MINOR
GENERAL NOTES
A. THE FOLLOWING GENERAL NOTES APPLY TO ALL A-SERIES DRAWINGS.
B. FOR GENERAL NOTES APPLICABLE TO ALL DRAWINGS REFER TO THE "PROJECT GENERAL NOTES" ON SHEET GI0.02 C. FOR GENERAL NOTES, ABBREVIATION, AND SYMBOLS APPLICABLE ONLY TO DRAWINGS OF A DISCIPLINE OTHER THAN ARCHITECTURE, REFER TO THE SPECIFIC DRAWINGS
OF THAT DISCIPLINE - SEE THE "INDEX OF DRAWINGS" ON SHEET GI0.01.
E. THE SPECIFICATIONS ARE INTENDED TO COMMUNICATE THE DETAILED PROPERTIES AND QUALITY OF THE INDIVIDUAL MATERIALS, ASSEMBLIES, AND SYSTEMS THAT COMPRISE THE WORK; THE FUNCTIONAL AND PERFORMANCE REQUIREMENTS FOR THE INDIVIDUAL PARTS OF THE WORK; AND THE FABRICATION AND INSTALLATION REQUIREMENTS FOR INDIVIDUAL PARTS OF THE WORK - THE SPECIFICATIONS TAKE PRECEDENCE OVER THE DRAWINGS WITH RESPECT TO INFORMATION OF THIS NATURE.
D. THE DRAWINGS ARE INTENDED TO GRAPHICALLY ILLUSTRATE THE OVERALL NATURE OF THE WORK; THE CONFIGURATION, ARRANGEMENT, AND LOCATION OF THE WORK AND ITS PARTS; AND THE PHYSICAL DIMENSIONS OF THE WORK - THE DRAWINGS TAKE PRECEDENCE OVER THE SPECIFICATIONS WITH RESPECT TO INFORMATION OF THIS
NATURE.
F. AS PART OF THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES, AND SUPPLIERS, THE CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND NOTIFY THE VA REPRESENTATIVE OF ANY CONFLICTS AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK, ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE
APPROVED IN ADVANCE BY THE VA REPRESENTATIVE.
G. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS, THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO THE DRAWINGS OF ANOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY.
DETAIL NUMBERING
H. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES, INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES, LOCATIONS SHOWN ON OTHER DRAWINGS ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS. THE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT
LOCATION OF ALL PARTS OF THE WORK,
EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHER DISCIPLINES SHALL GOVERN ONLY WHERE:
1. SPECIFICALLY AND INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR NOTATION ON THE ARCHITECTURAL DRAWINGS.
2. OCCURRING WITHIN A ROOM OR OTHER IDENTIFIED SPACE FOR WHICH ARCH SHEET OR SCHEDULE NOTES INDICATE THAT DIMENSIONS PROVIDED ELSEWHERE
SHALL GOVERN.
I. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND ELEVATIONS ILLUSTRATE THE EXACT LOCATION OF MANY, BUT NOT ALL, EXPOSED PARTS OF THE WORK, APPLY THE RULES INDICATED BY THE DRAWING "TYPICAL MOUNTING HEIGHTS AND CONFIGURATION DIAGRAMS" TO DETERMINE THE EXACT LOCATION OF
EACH EXPOSED PART OF THE WORK.
J. REFER TO THE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR THE DETAILED DESIGN OF STRUCTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING SYSTEMS, OF WHICH PORTIONS MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS.
K. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE FLOOR SLAB, UON. WHERE THE CONCRETE IS DEPRESSED TO ACCOMMODATE MORTAR BEDS, SETTING BEDS, RAISED ACCESS FLOORS, AND OTHER SIMILAR FLOOR ASSEMBLIES, FINISHED FLOOR ELEVATIONS ARE TO TOP OF FINISH FLOOR ASSEMBLY INDICATED.
L. CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES, UNLESS OTHERWISE NOTED.
M. FOR TYP DIMENSIONING CONVENTIONS, INCLUDING RULES FOR LOCATING DOORS WHICH HAVE NOT BEEN DIMENSIONED, REFER TO THE "ARCHITECTURALDIMENSIONING
CONVENTIONS" NOTES ON THIS SHEET.
N. FOR ILLUSTRATION AND DEFINITION OF TYPICAL SYMBOLS USED ON THE ARCHITECTURAL DRAWINGS, REFER TO THE "ARCHITECTURAL SYMBOLS" ON SHEET GI0.01
O. ADDITIONAL SYMBOLS, NOT SHOWN OR DEFINED ON THE DRAWING "ARCHITECTURAL SYMBOLS", MAY OCCUR AND ARE DEFINED ON OTHER ARCHITECTURAL DRAWINGS.
P. BASIC FIRE PROTECTION AND EXITING CONCEPTS ARE ILLUSTRATED BY GI0.04-SERIES "LIFE SAFETY " PLANS.
RATCLIFF PROJECT NO. 34019
NO REVISIONS DATE
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
KEY PLAN STAMP
ATTENTION:
ONLY WET SIGNED DOCUMENTS CONSTITUTE ADVANCE DESIGN CONSULTANTS, INC.
PROFESSIONAL WORK AND BECAUSE OTHER REPRODUCIBLE DOCUMENTS MAY BE EASILY
ALTERED WITHOUT THE CONSENT OF ADVANCE DESIGN CONSULTANTS, INC., THE WET
SIGNED DOCUMENTS MUST BE REFERRED TO FOR THE ORIGINAL AND CORRECT
INFORMATION. IF THERE ANY DIFFERENCES BETWEEN THE WET SIGNED DOCUMENTS AND
ANY O T H E R D O C U M E N T S , T H E W E T S I G N E D D O C U M E N T S S H A L L G O V E R N .
ADVANCE DESIGN CONSULTANTS, INC. IS NOT RESPONSIBLE FOR ANY MODIFICATIONS MADE
TO OUR DOCUMENTS BY ANYONE OTHER THAN AUTHORIZED REPRESENTATIVES OF
A D V A N C E D E S I G N C O N S U L T A N T S , I N C .
PRJ# 14-308-38
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
L. RIOS
AutoCAD SHX Text
J. ROTHWEIN
AutoCAD SHX Text
GI0.001
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
GI0.00
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
GI0.001
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
GI0.01
AutoCAD SHX Text
ABBREVIATIONS, MATERIALS AND SYMBOLS
AutoCAD SHX Text
GI0.02
AutoCAD SHX Text
PROJECT INFORMATION, APPLICABLE CODES AND GENERAL NOTES
AutoCAD SHX Text
GI0.03
AutoCAD SHX Text
PROGRAM AREA PHASE MATRIX
AutoCAD SHX Text
GI0.04
AutoCAD SHX Text
FIRST AND SECOND FLOOR FIRE SAFETY, EXIT PLANS AND FIRE RATING SCHEDULE
AutoCAD SHX Text
GI0.05
AutoCAD SHX Text
FIRST AND SECOND ACCESSIBILITY PLAN
AutoCAD SHX Text
GI0.06
AutoCAD SHX Text
REFERENCE - ACCESSIBILITY GENERAL REQUIREMENTS
AutoCAD SHX Text
GI0.07
AutoCAD SHX Text
ACCESSIBILITY REQUIREMENTS
AutoCAD SHX Text
GI0.08
AutoCAD SHX Text
CONTRACTOR STAGING LOCATION PLANS
AutoCAD SHX Text
AG1.1
AutoCAD SHX Text
SIGNAGE PLAN
AutoCAD SHX Text
AG1.2
AutoCAD SHX Text
SIGNAGE SCHEDULE
AutoCAD SHX Text
AG1.3
AutoCAD SHX Text
SIGNAGE PLANS AND SCHEDULES
AutoCAD SHX Text
AG1.4
AutoCAD SHX Text
CODE SIGNS
AutoCAD SHX Text
AG1.5
AutoCAD SHX Text
SIGNAGE PLANS AND SCHEDULES
AutoCAD SHX Text
CIVIL
AutoCAD SHX Text C001
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text C002
AutoCAD SHX Text
EXISTING CONDITIONS
AutoCAD SHX Text C003
AutoCAD SHX Text
EXISTING UNDERGROUND CONDITIONS
AutoCAD SHX Text
CD101
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
CP101
AutoCAD SHX Text
LAYOUT PLAN
AutoCAD SHX Text
CP102
AutoCAD SHX Text
GRADING PLAN
AutoCAD SHX Text
CP103
AutoCAD SHX Text
EROSION AND SEDIMENT CONTROL PLAN
AutoCAD SHX Text
CP501
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
CP502
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
CU101
AutoCAD SHX Text
UTILITY PLAN
AutoCAD SHX Text
LANDSCAPE
AutoCAD SHX Text
LP-1
AutoCAD SHX Text
PLANTING PLAN, NOTES, LEGEND AND DETAILS
AutoCAD SHX Text
LI-1
AutoCAD SHX Text
IRRIGATION PLAN
AutoCAD SHX Text
LI-2
AutoCAD SHX Text
IRRIGATION DETAILS
AutoCAD SHX Text
LI-3
AutoCAD SHX Text
IRRIGATION DETAILS
AutoCAD SHX Text
LI-4
AutoCAD SHX Text
IRRIGATION WATER USE CALCULATIONS AND WATERING SCHEDULE
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text S000
AutoCAD SHX Text
GENERAL INFORMATION
AutoCAD SHX Text S001
AutoCAD SHX Text
MATERIAL SPECIFICATIONS
AutoCAD SHX Text
SB101
AutoCAD SHX Text
FOUNDATION PLAN
AutoCAD SHX Text
SD101
AutoCAD SHX Text
SECOND FLOOR FRAMING PLAN
AutoCAD SHX Text
SF101
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text S501
AutoCAD SHX Text
TYPICAL CONCRETE SECTIONS AND DETAILS
AutoCAD SHX Text S502
AutoCAD SHX Text
TYPICAL STEEL SECTION AND DETAILS
AutoCAD SHX Text S503
AutoCAD SHX Text
FOUNDATION SECTION AND DETAILS
AutoCAD SHX Text S504
AutoCAD SHX Text
FLOOR FRAMING SECTIONS AND DETAILS
AutoCAD SHX Text S505
AutoCAD SHX Text
ROOF FRAMING SECTIONS AND DETAILS
AutoCAD SHX Text S506
AutoCAD SHX Text
FRAME ELEVATIONS SECTIONS AND DETAILS
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
AS1.0
AutoCAD SHX Text
ARCHITECTURAL SITE PLAN
AutoCAD SHX Text
AS1.1
AutoCAD SHX Text
FIRST FLOOR PLAN
AutoCAD SHX Text
AS1.1A9
AutoCAD SHX Text
FIRST FLOOR ADD #9
AutoCAD SHX Text
AS1.1A
AutoCAD SHX Text
FIRST FLOOR PLAN - EAST
AutoCAD SHX Text
AS1.1B
AutoCAD SHX Text
FIRST FLOOR PLAN - WEST
AutoCAD SHX Text
AS1.1S
AutoCAD SHX Text
FIRST FLOOR - SLAB PLAN
AutoCAD SHX Text
AS1.2
AutoCAD SHX Text
SECOND FLOOR PLAN
AutoCAD SHX Text
AS1.2.A1
AutoCAD SHX Text
SECOND FLOOR - ADD #1 SOUTH ROOMS
AutoCAD SHX Text
AS1.2.A2
AutoCAD SHX Text
SECOND FLOOR - ADD #2 NORTH ROOMS
AutoCAD SHX Text
AS1.2A
AutoCAD SHX Text
SECOND FLOOR PLAN - EAST
AutoCAD SHX Text
AS1.2B
AutoCAD SHX Text
SECOND FLOOR PLAN - WEST
AutoCAD SHX Text
AS1.2S
AutoCAD SHX Text
SECOND FLOOR - SLAB PLAN
AutoCAD SHX Text
AS1.5A
AutoCAD SHX Text
ROOF PLAN - EAST
AutoCAD SHX Text
AS1.5B
AutoCAD SHX Text
ROOF PLAN - WEST
AutoCAD SHX Text
AS1.5S
AutoCAD SHX Text
ROOF - SLAB PLAN
AutoCAD SHX Text
AS2.1A
AutoCAD SHX Text
FIRST FLOOR EQUIPMENT AND FURNITURE LAYOUT PLAN - EAST
AutoCAD SHX Text
AS2.1B
AutoCAD SHX Text
FIRST FLOOR EQUIPMENT AND FURNITURE LAYOUT PLAN - WEST
AutoCAD SHX Text
AS2.2A
AutoCAD SHX Text
SECOND FLOOR EQUIPMENT AND FURNITURE LAYOUT PLAN - EAST
AutoCAD SHX Text
AS2.2B
AutoCAD SHX Text
SECOND FLOOR EQUIPMENT AND FURNITURE LAYOUT PLAN - WEST
AutoCAD SHX Text
AS3.0.A
AutoCAD SHX Text
ARCHITECTURAL RENDERING - EAST ELEVATION
AutoCAD SHX Text
AS3.0.B
AutoCAD SHX Text
ARCHITECTURAL RENDERING - SOUTHEAST ELEVATION
AutoCAD SHX Text
AS3.1
AutoCAD SHX Text
EXTERIOR ELEVATIONS
AutoCAD SHX Text
AS3.2
AutoCAD SHX Text
BUILDING SECTIONS
AutoCAD SHX Text
AS3.3
AutoCAD SHX Text
EXTERIOR WALL SECTION
AutoCAD SHX Text
AS4.1
AutoCAD SHX Text
INTERIOR ELEVATIONS AND TYPICAL MOUNTING DETAILS
AutoCAD SHX Text
AS4.2
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.3
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.4
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.5
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.6
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.7
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.8
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
AS4.10A
AutoCAD SHX Text
TOILET ROOM INTERIOR ELEVATIONS AND ENLARGED PLANS
AutoCAD SHX Text
AS4.11A
AutoCAD SHX Text
TOILET ROOM INTERIOR ELEVATIONS AND ENLARGED PLANS
AutoCAD SHX Text
AS5.1A
AutoCAD SHX Text
FIRST FLOOR REFLECTED CEILING PLAN - EAST
AutoCAD SHX Text
AS5.1A.A5
AutoCAD SHX Text
FIRST FLOOR REFLECTED CEILING PLAN - ADD #5 WOOD CEILING
AutoCAD SHX Text
AS5.1B
AutoCAD SHX Text
FIRST FLOOR REFLECTED CEILING PLAN - WEST
AutoCAD SHX Text
AS5.2
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN BASE BID
AutoCAD SHX Text
AS5.2A.A1
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN - ADD #1 SOUTH ROOMS
AutoCAD SHX Text
AS5.2A.A2
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN - ADD #2 NORTH ROOMS
AutoCAD SHX Text
AS5.2A.A6
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN - ADD #6 SOFFITS
AutoCAD SHX Text
AS5.2A.A12
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN - ADD #12 EAST
AutoCAD SHX Text
AS5.2B.A12
AutoCAD SHX Text
SECOND FLOOR REFLECTED CEILING PLAN - ADD #12 WEST
AutoCAD SHX Text
AS6.1
AutoCAD SHX Text
STAIR NO. 1 - PLANS AND SECTIONS
AutoCAD SHX Text
AS6.2
AutoCAD SHX Text
STAIR NO. 2 - PLANS AND SECTIONS
AutoCAD SHX Text
AS6.3
AutoCAD SHX Text
STAIR, GUARDRAIL, HANDRAIL DETAILS
AutoCAD SHX Text
AS6.4
AutoCAD SHX Text
ELEVATOR PLAN AND SECTIONS
AutoCAD SHX Text
AS6.5
AutoCAD SHX Text
ELEVATOR DETAILS
AutoCAD SHX Text
AS7.0
AutoCAD SHX Text
WATERPROOFING DETAILS
AutoCAD SHX Text
AS7.1
AutoCAD SHX Text
EXTERIOR CURTAIN WALL / STOREFRONT ENLARGED DETAILS
AutoCAD SHX Text
AS7.2
AutoCAD SHX Text
EXTERIOR DETAILS
AutoCAD SHX Text
AS7.3
AutoCAD SHX Text
EXTERIOR DETAILS
AutoCAD SHX Text
AS7.4
AutoCAD SHX Text
TYPICAL ROOF DETAILS
AutoCAD SHX Text
AS7.5
AutoCAD SHX Text
EXTERIOR DETAILS
AutoCAD SHX Text
AS7.6
AutoCAD SHX Text
METAL PANEL DETAILS
AutoCAD SHX Text
AS7.8
AutoCAD SHX Text
EXTERIOR GATE & FENCE DETAILS
AutoCAD SHX Text
AS8.1A
AutoCAD SHX Text
PARTITION SCHEDULE, FRAMING AND BACKING SCHEDULE
AutoCAD SHX Text
AS8.1B
AutoCAD SHX Text
TYPICAL PARTITION DETAILS
AutoCAD SHX Text
AS8.1C
AutoCAD SHX Text
TYPICAL PARTITION DETAILS
AutoCAD SHX Text
AS8.2
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
AS8.3
AutoCAD SHX Text
DOOR DETAILS
AutoCAD SHX Text
AS8.4
AutoCAD SHX Text
FIRE RATED WINDOW AND DOOR DETAILS
AutoCAD SHX Text
AS8.5
AutoCAD SHX Text
TYPICAL CEILING DETAILS
AutoCAD SHX Text
AS8.6
AutoCAD SHX Text
INTERIOR DETAILS - CEILING
AutoCAD SHX Text
AS8.7
AutoCAD SHX Text
CASEWORK SCHEDULE AND DETAILS
AutoCAD SHX Text
AS9.1
AutoCAD SHX Text
FINISH SCHEDULE
AutoCAD SHX Text
AS9.2
AutoCAD SHX Text
INTERIOR DETAILS
AutoCAD SHX Text
AS9.3
AutoCAD SHX Text
FIRST FLOOR FINISH PLAN - EAST
AutoCAD SHX Text
AS9.4
AutoCAD SHX Text
FIRST FLOOR FINISH PLAN - WEST
AutoCAD SHX Text
AS9.5A
AutoCAD SHX Text
SECOND FLOOR FINISH PLAN - EAST
AutoCAD SHX Text
AS9.5B
AutoCAD SHX Text
SECOND FLOOR FINISH PLAN - WEST
AutoCAD SHX Text
AS9.6.A1
AutoCAD SHX Text
SECOND FLOOR FINISHED PLAN - ADD #1 SOUTH ROOMS
AutoCAD SHX Text
AS9.6.A2
AutoCAD SHX Text
SECOND FLOOR FINISHED PLAN - ADD #2 NORTH ROOMS
AutoCAD SHX Text
AS9.6A.A15
AutoCAD SHX Text
SECOND FLOOR FINISH PLAN - EAST - ADD #15
AutoCAD SHX Text
AS9.6B.A15
AutoCAD SHX Text
SECOND FLOOR FINISH PLAN - WEST - ADD #15
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text M-001
AutoCAD SHX Text
GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
AutoCAD SHX Text M-100
AutoCAD SHX Text
SITE PIPING PLAN AND SECTION
AutoCAD SHX Text M-101
AutoCAD SHX Text
FIRST FLOOR HVAC PLAN
AutoCAD SHX Text M-101.1
AutoCAD SHX Text
FIRST FLOOR HVAC EQUIPMENT PLAN
AutoCAD SHX Text M-102
AutoCAD SHX Text
FIRST FLOOR PIPING PLAN AND SECTION
AutoCAD SHX Text M-103
AutoCAD SHX Text
SECOND FLOOR HVAC PLAN AND SECTIONS
AutoCAD SHX Text M-103.1
AutoCAD SHX Text
SECOND FLOOR HVAC EQUIPMENT PLAN
AutoCAD SHX Text M-103A
AutoCAD SHX Text
MECHANICAL SECOND FLOOR HVAC PLAN - ADD #14
AutoCAD SHX Text M-104
AutoCAD SHX Text
MECHANICAL SECOND FLOOR PIPING PLAN - BASE
AutoCAD SHX Text M-104.A
AutoCAD SHX Text
MECHANICAL SECOND FLOOR PIPING PLAN - ADD #14
AutoCAD SHX Text M-105
AutoCAD SHX Text
ROOF HVAC PLAN AND SECTIONS
AutoCAD SHX Text M-105.A
AutoCAD SHX Text
MECHANICAL ROOF HVAC PLAN - ADD #14
AutoCAD SHX Text M-106
AutoCAD SHX Text
ROOF PIPING PLAN AND SECTIONS
AutoCAD SHX Text M-106.A
AutoCAD SHX Text
MECHANICAL ROOF PIPING PLAN - ADD #14
AutoCAD SHX Text M-107
AutoCAD SHX Text
(E) B702 ENERGY CENTER PIPING PLAN AND 3D VIEWS - NEW WORK
AutoCAD SHX Text M-108
AutoCAD SHX Text
FIRST FLOOR ZONING PLAN
AutoCAD SHX Text M-109
AutoCAD SHX Text
SECOND FLOOR ZONING PLAN
AutoCAD SHX Text M-501
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text M-502
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text M-503
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text M-504
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text M-505
AutoCAD SHX Text
MECHANICAL DETAILS
AutoCAD SHX Text
MC-601
AutoCAD SHX Text
MECHANICAL CONTROLS
AutoCAD SHX Text
MC-602
AutoCAD SHX Text
MECHANICAL CONTROLS
AutoCAD SHX Text
MC-603
AutoCAD SHX Text
MECHANICAL CONTROLS
AutoCAD SHX Text M-601
AutoCAD SHX Text
AIR FLOW DIAGRAM
AutoCAD SHX Text M-602
AutoCAD SHX Text
HW SYSTEM FLOW DIAGRAM
AutoCAD SHX Text M-603
AutoCAD SHX Text
CHW SYSTEM FLOW DIAGRAM
AutoCAD SHX Text M-604
AutoCAD SHX Text
CHW & HW PIPING DIAGRAMS
AutoCAD SHX Text M-605
AutoCAD SHX Text
HW PIPING RISER DIAGRAM AND 3D VIEWS
AutoCAD SHX Text M-701
AutoCAD SHX Text
EQUIPMENT SCHEDULES
AutoCAD SHX Text M-702
AutoCAD SHX Text
EQUIPMENT SCHEDULE
AutoCAD SHX Text M-901
AutoCAD SHX Text
ROOF EQUIPMENT 3D VIEWS
AutoCAD SHX Text M-902
AutoCAD SHX Text
ROOF PIPING 3D VIEW
AutoCAD SHX Text
PIPING
AutoCAD SHX Text P-001
AutoCAD SHX Text
GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
AutoCAD SHX Text P-101
AutoCAD SHX Text
FIRST FLOOR SANITARY SEWER & STORM DRAIN PLAN
AutoCAD SHX Text P-102
AutoCAD SHX Text
FIRST FLOOR DOMESTIC WATER PLAN
AutoCAD SHX Text P-103
AutoCAD SHX Text
SECOND FLOOR SANITARY SEWER & STORM DRAIN PLAN
AutoCAD SHX Text P-104
AutoCAD SHX Text
SECOND FLOOR DOMESTIC WATER PLAN
AutoCAD SHX Text P-105
AutoCAD SHX Text
PLUMBING ROOF PLAN AND 3D VIEW
AutoCAD SHX Text P-501
AutoCAD SHX Text
PIPING DETAILS
AutoCAD SHX Text P-502
AutoCAD SHX Text
PIPING DETAILS
AutoCAD SHX Text
PC-601
AutoCAD SHX Text
DOMESTIC WATER CONTROLS DIAGRAM
AutoCAD SHX Text P-601
AutoCAD SHX Text
PIPING SCHEDULES
AutoCAD SHX Text P-602
AutoCAD SHX Text
WASTE/VENT AND STORM WATER RISER DIAGRAMS
AutoCAD SHX Text P-603
AutoCAD SHX Text
DOMESTIC WATER RISER DIAGRAM
AutoCAD SHX Text P-901
AutoCAD SHX Text
SANITARY SEWER, VENT AND STORM DRAIN ISOMETRICS
AutoCAD SHX Text P-902
AutoCAD SHX Text
SANITARY SEWER & VENT ISOMETRICS
AutoCAD SHX Text P-903
AutoCAD SHX Text
DOMESTIC WATER ISOMETRICS
AutoCAD SHX Text P-904
AutoCAD SHX Text
DOMESTIC WATER ISOMETRICS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text E-001
AutoCAD SHX Text
GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
AutoCAD SHX Text
ED-101
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text E-101
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text E-101.1
AutoCAD SHX Text
ENLARGED ELECTRICAL ROOMS LOCATION
AutoCAD SHX Text E-101.2
AutoCAD SHX Text
NEW WORK AREA PLAN
AutoCAD SHX Text
EP-101
AutoCAD SHX Text
FIRST FLOOR POWER PLAN
AutoCAD SHX Text
EP-101A
AutoCAD SHX Text
FIRST FLOOR POWER PLAN BID ADD ALTS
AutoCAD SHX Text
EP-101.1
AutoCAD SHX Text
FIRST FLOOR EQUIPMENT POWER PLAN
AutoCAD SHX Text
EP-101.2
AutoCAD SHX Text
ENLARGED PLANS
AutoCAD SHX Text
EP-102
AutoCAD SHX Text
SECOND FLOOR POWER PLAN
AutoCAD SHX Text
EP-102A
AutoCAD SHX Text
SECOND FLOOR POWER PLAN BID ADD ALTS
AutoCAD SHX Text
EP-102.1
AutoCAD SHX Text
SECOND FLOOR EQUIPMENT POWER PLAN
AutoCAD SHX Text
EP-103
AutoCAD SHX Text
EQUIPMENT POWER PLAN
AutoCAD SHX Text
EP-104
AutoCAD SHX Text
GROUNDING PLAN
AutoCAD SHX Text
EL-101
AutoCAD SHX Text
FIRST FLOOR LIGHTING PLAN
AutoCAD SHX Text
EL-101A
AutoCAD SHX Text
FIRST FLOOR LIGHTING PLAN BID ADD ALTS
AutoCAD SHX Text
EL-102
AutoCAD SHX Text
SECOND FLOOR LIGHTING PLAN
AutoCAD SHX Text
EL-102A
AutoCAD SHX Text
SECOND FLOOR LIGHTING PLAN BID ADD ALTS
AutoCAD SHX Text
EL-103
AutoCAD SHX Text
ROOF LIGHTING PLAN
AutoCAD SHX Text E-601
AutoCAD SHX Text
SINGLE LINE DIAGRAM, EQUIPMENT SYSTEM AND LIFE SAFETY
AutoCAD SHX Text E-602
AutoCAD SHX Text
NORMAL/CRITICAL POWER NW SINGLE LINE DIAGRAM
AutoCAD SHX Text E-603
AutoCAD SHX Text
LIGHTING CONTROL DIAGRAMS
AutoCAD SHX Text E-701
AutoCAD SHX Text
PANEL SCHEDULE
AutoCAD SHX Text E-702
AutoCAD SHX Text
LIGHT FIXTURE SCHEDULE
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
QV101
AutoCAD SHX Text
FIRST FLOOR VIDEO AND DOOR SECURITY PLAN
AutoCAD SHX Text
QV102
AutoCAD SHX Text
SECOND FLOOR VIDEO AND DOOR SECURITY PLAN
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text
FA-001
AutoCAD SHX Text
FIRE ALARM AND DETECTION ABBREVIATIONS, SYMBOLS EQUIP. SCHEDULE
AutoCAD SHX Text
FA-101
AutoCAD SHX Text
FIRST FLOOR FIRE ALARM PLAN
AutoCAD SHX Text
FA-102
AutoCAD SHX Text
SECOND FLOOR FIRE ALARM PLAN
AutoCAD SHX Text
FA-601
AutoCAD SHX Text
RISER DIAGRAM
AutoCAD SHX Text
PA-101
AutoCAD SHX Text
PUBLIC ADDRESS SYSTEM FLOOR PLAN
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
FP-0
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
FP-1
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
FP-2
AutoCAD SHX Text
1ST FLOOR CEILING PLAN
AutoCAD SHX Text
FP-2.1
AutoCAD SHX Text
1ST FLOOR PIPING PLAN
AutoCAD SHX Text
FP-3
AutoCAD SHX Text
2ND FLOOR CEILING PLAN
AutoCAD SHX Text
FP-3.1
AutoCAD SHX Text
2ND FLOOR PIPING PLAN
AutoCAD SHX Text
FP-4
AutoCAD SHX Text
SECTIONS AND DETAILS
AutoCAD SHX Text
FP-5
AutoCAD SHX Text
BRACE DETAILS
AutoCAD SHX Text
FP-5.1
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
FP-6
AutoCAD SHX Text
FIRE PUMP
AutoCAD SHX Text
TELECOMMUNICATIONS
AutoCAD SHX Text T-0001
AutoCAD SHX Text
DRAWING INDEX, LEGEND, GENERAL NOTES AND ABBREVIATIONS
AutoCAD SHX Text T-1000
AutoCAD SHX Text
TECHNOLOGY OVERALL SITE PLAN
AutoCAD SHX Text T-1001
AutoCAD SHX Text
TECHNOLOGY WORK AREA OUTLET PLAN - 1ST FLOOR
AutoCAD SHX Text T-1002
AutoCAD SHX Text
TECHNOLOGY WORK AREA OUTLET PLAN - 2ND FLOOR
AutoCAD SHX Text T-1003
AutoCAD SHX Text
TECHNOLOGY PATHWAY PLAN 1ST FLOOR
AutoCAD SHX Text T-1004
AutoCAD SHX Text
TECHNOLOGY PATHWAY PLAN 2ND FLOOR
AutoCAD SHX Text T-1005
AutoCAD SHX Text
TECHNOLOGY PATHWAY PLAN 1ST FLOOR
AutoCAD SHX Text T-1006
AutoCAD SHX Text
TECHNOLOGY PATHWAY PLAN - ADD #1 SOUTH ROOMS 2ND FLOOR
AutoCAD SHX Text T-1007
AutoCAD SHX Text
TECHNOLOGY PATHWAY PLAN - ADD #2 NORTH ROOMS 2ND FLOOR
AutoCAD SHX Text T-4001
AutoCAD SHX Text
TECHNOLOGY ENLARGED IDF ROOM - 1ST FLOOR
AutoCAD SHX Text T-4002
AutoCAD SHX Text
TECHNOLOGY RACK ELEVATION IDF ROOM - 1ST FLOOR
AutoCAD SHX Text T-4003
AutoCAD SHX Text
TECHNOLOGY ENLARGED IDF ROOM - 2ND FLOOR
AutoCAD SHX Text T-4004
AutoCAD SHX Text
TECHNOLOGY RACK ELEVATION IDF ROOM - 2ND FLOOR
AutoCAD SHX Text T-5001
AutoCAD SHX Text
TECHNOLOGY SINGLE LINE DIAGRAM
AutoCAD SHX Text T-6001
AutoCAD SHX Text
TELECOM DETAILS
AutoCAD SHX Text T-6002
AutoCAD SHX Text
TELECOM DETAILS
AutoCAD SHX Text T-6003
AutoCAD SHX Text
TELECOM DETAILS
AutoCAD SHX Text T-6004
AutoCAD SHX Text
TELECOM DETAILS
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231, OCT 1978
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS (14-272)
AutoCAD SHX Text 11/7/17
AutoCAD SHX Text 612-400
AutoCAD SHX Text
AutoCAD SHX Text
CONSTRUCT PRIMARY CARE SERVICES BLDG.
AutoCAD SHX Text
10535 HOSPITAL WAY, MATHER, CA.
AutoCAD SHX Text
FINAL ISSUE FOR BID
AutoCAD SHX Text
FINAL BID DOCUMENTS (14-273)
AutoCAD SHX Text 3/9/18
AutoCAD SHX Text 5/4/18
AutoCAD SHX Text
FINAL ISSUE FOR BID (14-276)
AutoCAD SHX Text 5/4/18
AutoCAD SHX Text O
AutoCAD SHX Text
EXP. 06/30/2017
AutoCAD SHX Text
NO. M 21000
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text Z
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text BUY AMERICAN ACT CONTRACTOR SHALL COMPLY WITH BUY AMERICAN ACT AS PRESCRIBED IN FAR PART 25.1 - SUPPLIES AND PART 25.2 - CONSTRUCTION MATERIALS.
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEV BEVEL
BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BOT BOTTOM
BR BEDROOM
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS OR CHANNEL
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN OR CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY OR CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
cm² SQUARE CENTIMETER cm³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF OCCUPANCY,
CLEANOUT, OR COMPANY
CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER CONTOUR
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE or FINISH FLOOR
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR FIBERGLASS
REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HQ HEADQUARTERS
HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE or LATENT HEAT RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM
MED MEDIUM or MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE or MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MOTOR OPERATED
MOD MODEL, MODIFY/MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE DIMENSION
OD OUTSIDE DIMENSION OUTSIDE DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION
OUT OUTLET
OZ OUNCE
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND CEMENT
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PROPERTY LINE or PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PO POST OFFICE or PURCHASE ORDER
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY OR REFRIGERATION
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR, OR SOAP DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE OR WEST
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL INSTITUTE
FWC FABRIC WALLCOVERING
GA GAGE /GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE
YD YARD
YR YEAR
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
OPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
SECOND LEVEL
+10'-0"
BUILDING SECTION
BUILDING SECTION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
WALL SECTION
WALL SECTION NUMBER
NORTH ARROW REFERENCE
PROJECT NORTH
NEW GRIDLINE
IDENTIFICATION
LAYOUT GRID LINES
BASIC DRAWING TITLE
SHEET WHERE DRAWN
DIRECTION OF VIEW
LEVEL LINE
REVISION NUMBER AND EXTENT
ROOM NAME AND NUMBER
PLAN DETAIL REFERENCE
SECTION DETAIL REFERENCE
DETAIL REFERENCE
EXTERIOR ELEVATION
AX.XX 2
INTERIOR ELEVATION REFERENCE
SEE PARTITION SYMBOL
DESCRIPTION ON SHEET
A9.X.X
PARTITION TYPE IDENTIFICATION MARK
ELEVATION NUMBER
SHEET WHERE DRAWN
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION OF VIEW
SHEET WHERE DRAWN,
HYPHEN INDICATES DETAIL
ON SAME SHEET.
DETAIL NUMBER
DETAIL NUMBER
SHEET WHERE DRAWN,
DASH TEXT INDICATES
DETAIL ON SAME SHEET
SHEET WHERE DRAWN
SECTION DETAIL NUMBER
AX.XX X
WINDOW AND LOUVER TYPE MARK
SEE CORRESPONDING
NUMBER ON WINDOW
SCHEDULE
NAME OF LEVEL
INDICATES HEIGHT ABOVE
PROJECT DATUM
REVISION NUMBER - SEE
REVISION HISTORY ON
THE TITLE BLOCK OF EACH
SHEET
EXTENT OF CURRENT
REVISION
KEYED NOTE MARK
MATCH LINE REFERENCE
DRAWING TITLE SYMBOLS
SEE CORRESPONDING
KEY NOTE LEGEND ON
SHEET WHERE
REFERENCE OCCURS
DRAWING SIDE
DRAWING WHERE
CONTINUATION IS FOUND
A
SCALE:
AX.XX
AX.XX
SIM
AX.XX
AX.XX
SIM
AX.XX
SIM
MATCHLINE, SEE X/AX.XX
ROOM NAME
WX
0A3X
1 View Name 1/8" = 1'-0"
ELEVATION NUMBER
90°
AX.XX
BASE CABINETS
BASE AND WALL CABINETS
WALL CABINETS
TOILET PARTITION AND DOOR
TOILET - WALL HUNG
URINAL - FLOOR/WALL HUNG
LAVATORY - COUNTERTOP
LAVATORY - PEDESTAL/WALL HUNG
GENERAL SYMBOLS
PLUMBING SYMBOLS
10' - 0"
HANDRAIL
BUMPER GUARD
CG CG
CORNER GUARD
EDGE GUARD
OVERHEAD ITEMS
UNDER-COUNTER ITEMS NIC NOT-IN-CONTRACT ITEMS
10' - 0"
10' - 0"
JANITOR'S RECEPTOR
DRINKING FOUNTAIN / EWC
EG
DIMENSION SYMBOLS
UTILITY SINK
BATHTUB
SHOWER
FLOOR DRAIN IN SLOPING FLOOR
FEC
FEC
FEXT
FEC
FIRE EXTINGUISHER
BRACKET MOUNTED
FIRE EXTINGUISHER
SURFACE MOUNTED
FIRE EXTINGUISHER CABINET
SEMI-RECESSED
FIRE EXTINGUISHER CABINET
RECESSED
DIMENSION SHOWN TO:
- STRUCTURAL GRID
- LAYOUT GRID
GRID LINE TYPICAL
DIMENSION SHOWN TO:
- CENTERLINE OF ASSEMBLY
- CENTER OF OPENING
- CENTER OF EQUIP/ FURN
CENTER LINE TYPICAL
DIMENSION SHOWN TO:
- FACE OF GYP BD
- EDGE OF DOOR OPENING
- OTHER BUILDING ELEMENT
- WPT INDICATED ON DETAIL
CRASH RAIL
OVERHEAD ROLLING DOOR
PAIR DOORS - UNEQUAL SIZES
DOUBLE ACTING DOOR
SINGLE OPENING DOOR
2 PANEL BI-FOLD DOOR
PAIR - BI FOLD DOOR
DOOR OPENING MARK
PAIR DOORS - EQUAL SIZES
PAIR DOORS - DOUBLE EGRESS
DOOR WITH SIDE LIGHT
SLIDING DOOR - BETWEEN JAMBS
SLIDING POCKET DOOR
INTERIOR GLAZED WINDOW
ARCHITECTURAL
MECHANICAL
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
ELECTRICAL
MISCELLANEOUS
2'X4' FLUORESCENT FIXTURE
2'X2' FLUORESCENT FIXTURE
LINEAR FLUORESCENT FIXTURE
FLUORESCENT STRIP FIXTURE
RECESSED DOWN LIGHT
WALL MOUNTED SCONCE
WALL MOUNTED LINEAR
EXIT SIGN, SINGLE-SIDED
EXIT SIGN, DOUBLE-SIDED
FIRE ALARM
SPEAKER
SMOKE DETECTOR
WIRELESS INTERNETW
P
S
FHEIGHT OF CEILING FINISH
ABOVE FINISH FLOOR
+12'-8"
FLUORESCENT COVE LIGHTING
(SEE REFLECTED CEILING PLAN SHEETS FOR MATERIAL
LEGEND)
EARTH
AGGREGATE BASE COURSE
CONCRETE
CONCRETE MASONRY UNIT
BRICK MASONRY
LIMESTONE, SANDSTONE, GRANITE
MARBLE
STEEL, STAINLESS STEEL
(LARGE SCALE)
ALUMINUM (LARGE SCALE)
OTHER METALS (LARGE
SCALE)
WOOD FRAMING -
CONTINUOUS (LARGE SCALE)
WOOD FRAMING - DISCONTINUOUS
(LARGE SCALE)
PLYWOOD
(LARGE SCALE)
FINISH WOOD (LARGE SCALE)
SEMI-RIGID INSULATION
(LARGE SCALE)
BATT INSULATION
(LARGE SCALE)
MORTAR, SAND, FIREPROOFING,
STUCCO, GYPSUM BOARD
TERRAZZO (LARGE SCALE)
COMPOSITE BOARD
(LARGE SCALE)
ACOUSTIC TILE (LARGE SCALE)
PROTECTION BOARD
(LARGE SCALE)
CERAMIC TILE (LARGE SCALE)
GLASS (LARGE SCALE)
SCREEN WALL METAL PANEL VISION GLASS
ELEVATION
PLAN AND SECTION
METAL PANEL
THERMA -FIBER
on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot
6" on e in ch o ne fo ot on e an d on e-ha lf in ch o ne fo ot th re e in ch es o ne fo ot
6"
6"
6"
1 2 3 4 5 6
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
7 8 9
VA FORM 08-6231, OCT 1978
Date
Approved: Project Director
Drawing Title: Project Title:
Location
Project Number:
Building Number:
Drawing Number:
Checked Drawn
ARCHITECT/ENGINEERS
STAMP
Office of Facilities
Management
Dwg. of
ONLY WET SIGNED DOCUMENTS CONSTITUTE ADVANCE DESIGN CONSULTANTS, INC.
PROFESSIONAL WORK AND BECAUSE OTHER REPRODUCIBLE DOCUMENTS MAY BE
EASILY ALTERED WITHOUT THE CONSENT OF ADVANCE DESIGN CONSULTANTS, INC.,
THE WET SIGNED DOCUMENTS MUST BE REFERRED TO FOR THE ORIGINAL AND
CORRECT INFORMATION. IF THERE ARE ANY DIFFERENCES BETWEEN THE WET
SIGNED DOCUMENTS AND ANY OTHER DOCUMENTS, THE WET SIGNED DOCUMENTS
SHALL GOVERN.
ADVANCE DESIGN CONSULTANTS, INC. IS NOT RESPONSIBLE FOR ANY
MODIFICATIONS MADE TO OUR DOCUMENTS BY ANYONE OTHER THAN AUTHORIZED
REPRESENTATIVES OF ADVANCE DESIGN CONSULTANTS, INC.
PO# 13-308-39
ATTENTION:
KEY PLANCONSULTANTS:
95% CONSTRUCTION DOCUMENTS (14-272) 11/7/17
5/4/18
1 9 A
G
FINAL ISSUE FOR BID
FINAL BID DOCUMENTS (14-273) 3/9/18
FINAL ISSUE FOR BID (14-276) 5/4/18
D:
\R ev itL oc als
\A
9_
Pr im ar yC ar e_
CO
NT
AI
NE
R1 7_ do lse n@ ra tcl iffa rch .co m.
rvt
5/4/2018 11:55:51 AM
GI0.01
ABBREVIATIONS, MATERIALS AND SYMBOLS CONSTRUCT PRIMARY CARE SERVICES
BLDG.
612-400
10535 HOSPITAL WAY MATHER, CA.
Checker Author
ARCHITECTURAL MATERIAL INDICATIONS
ARCHITECTURAL REFERENCE SYMBOLS
DOOR & INTERIOR OPENING SYMBOLS
ARCHITECTURAL REFLECTED CEILING
MATERIALS
ARCHITECTURAL FLOOR PLAN SYMBOLS
RESTROOM ACCESSORIES
SEE SHEET AE7.1.4 FOR LOCATION OF RESTROOM ACCESSORIES.
SEE SPECIFICATION SECTION 10 28 00 FOR MORE INFORMATION.
VV VA PROVIDED AND INSTALLED
VC VA PROVIDED, CONTRACTOR INSTALLED
CC CONTRACTOR PROVIDED AND INSTALLED
DISPENSER, SOAP, DISPOSABLE VV
DISPENSER, PAPER TOWEL, SURFACE MOUNTED VV
DISPOSAL, SANITARY NAPKIN, SURFACE MOUNTED VC
GRAB BAR, 1-1/4" DIA, SST, 2 WALL CC
HOOK, GARMENT, DOUBLE, SST, SURFACE MOUNTED CC
DISPENSER, TOILET TISSUE, SST, 2-ROLL, SURFACE MOUNTED VV
BASKET, WASTEPAPER, ROUND, METAL VV
DISPENSER, SURFACE MOUNTED, SEAT COVER VC
GRAB BAR, 1-1/4" DIA, SST CC
DISPENSER, SURFACE MOUNTED, SANITARY NAPKIN VC
o n e e i g h t h i c e f o o t o n e q u a r t e r i n e f o o t t h r e e e i g h t i e f o o t o n e h a l f i n e f o o t t h r e e q u a r t e r s i n e f o o t o n e i n e f o o t o n e a n d o n e h a l f i n e f o o t t h r e e i n c h e s e f o o t
1 2 3 4 5 6
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
7 8 9
VA FORM 08-6231, OCT 1978
Date
Approved: Project Director
Drawing Title: Project Title:
Location
Project Number:
Building Number:
Drawing Number:
Checked Drawn
ARCHITECT/ENGINEERS
STAMP
Office of Facilities
Management
Dwg. of
ONLY WET SIGNED DOCUMENTS CONSTITUTE ADVANCE DESIGN CONSULTANTS, INC.
PROFESSIONAL WORK AND BECAUSE OTHER REPRODUCIBLE DOCUMENTS MAY BE
E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .