Attachment K - M-100 Piping.pdf

PDF 1004 KB Posted

Attached to
Y1DA--Construct Primary Care at VANCHCS, Mather Campus Federal contract opportunity
Solicitation number
36C26119B0014
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21

About this file

This document summarizes a federal contract solicitation for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 is seeking a single fixed-price contract to construct a new 14,857 square foot Primary Care building, designated as building 642, on the campus of the Department of Veterans Affairs Northern California Healthcare System in Mather, California. The scope of work includes site preparation, demolition, and construction of the new two-story building. The total construction cost is estimated between $5 million and $10 million. The completion period is 425 calendar days from notice to proceed. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses only and will be awarded in accordance with Federal Acquisition Regulation procedures for sealed bidding. The solicitation number is 36C26119B0014 and was issued on May 27, 2020.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--Construct Primary Care at VANCHCS, Mather Campus, newest first.
File Type Posted
Bid Opening Roll Call for Project 612-400--Construct Primary Care Services at Mather VAMC--8.31.2020.pdf PDF
Abstract of Offers for Project 612-400--Construct Primary Care Services--8.31.2020.pdf PDF
Amendment 0004 (SF30) to 36C26119B0014.docx DOCX document
Attachment U - Railings.pdf PDF
36C26119B0014_Amendment_0003--Construct_Primary_Care_Services--8.20.2020.docx DOCX document
Amendment 0003 (SF30) to 36C26119B0014.docx DOCX document
Attachment S - Signage.pdf PDF
Attachment T - Construction Area Border Line.pdf PDF
Attachment I -RFIs to be Incorporated into 36C26119B0014--8.20.2020.pdf PDF
Attachment Q - 08 36 16.3 Barn (Sliding) Door.pdf PDF
Amendment 0002 (SF30) to 36C26119B0014.docx DOCX document
Attachment I -RFIs to be Incorporated into 36C26119B0014--8.18.2020.pdf PDF
Attachment P - Domestic Water.pdf PDF
Attachment R - AS8.8 from Primary Care BID 2016.pdf PDF
Amendment 0001 (SF30) to 36C26119B0014.docx DOCX document
Attachment O - JOFOC Johnson Controls - Approved_Redacted.pdf PDF
Attachment J - 2472 VA Mather Primary Care Facility Geotechnical Report Combined.pdf PDF
Attachment I -RFIs to be Incorporated into 36C26119B0014--8.14.2020.pdf PDF
36C26119B0014_Amendment_0001--Construct_Primary_Care_Services--8.14.2020.docx DOCX document
Attachment N - 2nd FLR Wall Types.pdf PDF
Amendment 0001--Submission of Bids (electronic bids).pdf PDF
Attachment M - 23 21 13 Hydronic Piping Spec.pdf PDF
Attachment L - Fire Alarm Panel in BLDG 650 - Secutron.pdf PDF
Pre-Bid Conference Agenda for Mather VAMC Construct Primary Care.pdf PDF
Site Visit Sign-in Sheet for Mather VAMC Construct Primary Care.pdf PDF
IFB 36C26119B0014--Construct Primary Care--Site Visit Info Updated 7.22.2020.docx DOCX document
Attachment G - CONTRACTOR CERTIFICATION REGARDING SAFETY AND ENVIRONMENTAL.docx DOCX document
Attachment A - Specifications (combined).pdf PDF
Attachment C - Add Alternate Explanation.pdf PDF
Attachment D - Wage Determination CA202000007.pdf PDF
Attachment B.1 - PRIMARY CARE BLDG Drawings.pdf PDF
Attachment E - DIVISION CONSTRUCTION COSTS.docx DOCX document
Attachment F - REQUEST FOR INFORMATION (RFI) FORM.docx DOCX document
IFB 36C26119B0014--Construct Primary Care.docx DOCX document
Attachment H - VHA Directive 7715--Safety and Health During Construction.pdf PDF
Attachment B.2 - PRIMARY CARE BLDG Drawings-2.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6 7 8 8.4 9

A

A

B

C D

MA

MB

M1

3 4

E

6 87

F

2.5 5

B M-102

(N) B642FOR CONTINUATION

SEE SHEET M-102

(N) 2 1/2"ø HWS

(N) 2 1/2"ø HWR

(N) 3"ø CHS

(N) 3"ø CHR

ROOF OF (E) B650

(N) B644

ROOF OF (E) B650

(N) 3"ø HWS

(N) 3"ø HWR

(N) 4"ø CHR

(N) 4"ø CHS

(N) 3"ø CHS

(N) 3"ø CHR

(N) 2 1/2"ø HWR

(N) 2 1/2"ø HWS

UNDERGROUND PIPES TO (N)

B644. SEE CIVIL DRAWINGS FOR

CONTINUATION

(E) HWS/R

(E) CHS/R

(E) HWS/R

(E) CHS/R

(N) CH & HW PIPES ON

TOP OF (E) PIPES

(N) 3"ø HWS

(N) 3"ø HWR

(N) 4"ø CHR

(N) 4"ø CHS

(N) SEISMIC EXPANSION JOINT (TYP)

(E) CHS/R

(E) EF

(E) EF

(E) EF

(E) EF

(E) EF

(E) CHS/R

ROOF OF (E) B650

(E) B702 (ENERGY

CENTER)

(N) 3"ø HWR

(N) 3"ø HWS (N) 4"ø CHR

(N) 4"ø CHS

(N) SEISMIC EXPANSION JOINT (TYP)

(E) CHS/R & HWS/R

(E) CHS/R

(E) CHS/R

(N) NESTED THERMAL

EXPANSION LOOP (TYP)

(E) EF

(E) CROSSOVER

(E) CROSSOVER

(E) CROSSOVER

(E) AHU

(E) EF

(E) AHU

(E) AHU

(E) AHU(E) AHU

(E) AHU

(E) AHU

(E) AHU

(E) AHU

(N) 2 1/2"ø HWS

(N) 2 1/2"ø HWR

(N) 3"ø CHS

(N) 3"ø CHR

DN BELOW GRADE

SHEET NOTES:

PROVIDE SEISMIC EXPANSION JOINT AT LOCATIONS

INDICATED ON PLAN. METRAFLEX METRALOOP VLF80300

(3") & VLF80400 (4"), ±4" MOVEMENT.

PROVIDE THERMAL EXPANSION JOINT AT LOCATION

INDICATED ON PLAN. METRAFLEX METRALOOP MLF80250

(2-1/2") & MLF80300 (3"), ±4" MOVEMENT.

PROVIDE (N) CROSSOVER LADDER AT THE POINTS

INDICATED ON PLAN. FIELD COORDINATE EXACT

LOCATION TO CLEAR ALL OBSTACLES. SEE STRUCTURAL

DWGS FOR ANCHORING.

PROVIDE SEISMIC EXPANSION JOINT AT LOCATIONS

INDICATED ON PLAN. METRAFLEX METRALOOP VLF80250

(2-1/2") & VLF80300 (3"), ±4" MOVEMENT.

SEE SHEET M-107 FOR PIPES CONTINUATION AND POINT

OF CONNECTIONS.

FOR CONTINUATION

SEE SHEET M-107

FOR CONTINUATION

SEE SHEET M-107

(N) SEISMIC EXPANSION JOINT (TYP)4

(N) CROSSOVER

(N) CROSSOVER

(N) CROSSOVER

SEE M-102 ON BLDG 644 PROJECT # 612-401 FOR CONTINUATION

CHW & HW ISOLATION VALVES VAULT. SEE DETAILS ON M-505

(N) PIPE ANCHORS (TYP)

(N) PIPE ALIGNMENT GUIDE (TYP)

(N) PIPE ANCHORS (TYP)

A M-100

(E) BLDG 650

(E) BLDG 650 TOWER

(N) 3"ø HWS

(N) 3"ø HWR

(N) 4"ø CHR

(N) 4"ø CHS

FROM/TO (E) BLDG 702

(ENERGY CENTER)

TO/FROM (N)

BLDG 642 & (N)

B644

(N) PIPE ANCHOR (TYP)

STRUC SUPPORT NOT SHOWN

(E) BLDG 650 SEISMIC JOINT

(E) CHS/R & HWS/R V-LOOP SEISMIC JOINT

(N) CHS/R & HWS/R SEISMIC JOINT 1

(E) BLDG 650 ROOF

(E) CH & HW PIPES

MENTAL HEALTH BUILDING CONTRACTOR SHALL

CONNECT TO SITE CHW & HW UTILITY PIPING

ISOLATION VALVE (TYP-4) NOT IN SCOPE OF THIS PROJECT

PART OF VA UTILITY WORK

ISOLATION VALVE (TYP-4)

BY MENTAL HEALTH BUILDING CONTRACTOR

ISOLATION VALVE (TYP-4)

BY MENTAL HEALTH BUILDING CONTRACTOR

POINT OF CONNECTION FOR PRIMARY CARE

BUILDING CONTRACTOR SCOPE OF WORK

CHW & HW PIPES NOT IN SCOPE OF WORK OF THIS PROJECT

PART OF VA UTILITY WORK

O

EXP. 06/30/2017

NO. M 21000

F A

C

ET

AT

S

NHC A CI

OF AC IL

EM

NZ

D

ET

RE

G

SI

LO

ER

RE O

R

FRO

A P

ESSI

OI S

RNO

AL I

STA

NGE

NO

LL

I

R

NEE

E

NAL

Date

Approved: Project Director

Drawing Title: Project Title:

Location

Project Number:

Building Number:

Drawing Number:

Checked Drawn

ARCHITECT/ENGINEERS

STAMPKEY PLANCONSULTANTS:

Office of Facilities

Management

Dwg. of

ONLY WET SIGNED DOCUMENTS CONSTITUTE ADVANCE DESIGN CONSULTANTS, INC.

PROFESSIONAL WORK AND BECAUSE OTHER REPRODUCIBLE DOCUMENTS MAY BE

EASILY ALTERED WITHOUT THE CONSENT OF ADVANCE DESIGN CONSULTANTS, INC.,

THE WET SIGNED DOCUMENTS MUST BE REFERRED TO FOR THE ORIGINAL AND

CORRECT INFORMATION. IF THERE ARE ANY DIFFERENCES BETWEEN THE WET

SIGNED DOCUMENTS AND ANY OTHER DOCUMENTS, THE WET SIGNED DOCUMENTS

SHALL GOVERN.

ADVANCE DESIGN CONSULTANTS, INC. IS NOT RESPONSIBLE FOR ANY

MODIFICATIONS MADE TO OUR DOCUMENTS BY ANYONE OTHER THAN AUTHORIZED

REPRESENTATIVES OF ADVANCE DESIGN CONSULTANTS, INC.

PO# 13-308-38

ATTENTION:

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

FINAL BID DOCUMENTS

3/9/18 M-100

MECHANICAL SITE PIPING PLAN &

SECTION

CONSTRUCT PRIMARY CARE

SERVICES BLDG.

612-400

10535 HOSPITAL WAY MATHER,CA.

G. YOUSSEFI R. SOTELO

N SCALE: 1/16" = 1'-0"

MECHANICAL SITE PIPING PLAN

SCALE: 1/4" = 1'-0"A MECHANICAL PIPING SECTION VIEW

NOT IN SCOPE OF WORK OF THIS PROJECT

PART OF VA UTILITY WORK

NOT IN SCOPE OF WORK OF THIS PROJECT

PART OF MENTAL HEALTH BUILDING PROJECT

MECHANICAL SITE PIPING SCOPE OF WORK SPLIT 3D VIEW

SEE 3D VIEW ON THIS SHEET

Revisions: Date

95% CONSTRUCTION DOCUMENTS (14-272) 11/7/17

FINAL BID DOCUMENTS (14-273) 3/9/18

VHAMACGuptaS1 Rectangle

VHAMACGuptaS1 Polygon

VHAMACGuptaS1 Line

VHAMACGuptaS1 Text Box Planned taps that would go to the new bump out BLDG 642 from BLDG 650 by BLDG 646