ATTACHMENT 9 - Drawings - Part 6.pdf

PDF 13 MB Posted

Attached to
Y1DA--Specialty Treatment Expansion (Minor) Construction - Tampa
Solicitation number
36C77623B0016
Issued by

About this file

This file is an attachment to a federal contract solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking proposals to expand specialty treatment facilities at the Tampa VA Medical Center. Offerors must submit proposals by the date specified in solicitation number 36C77623B0016 to be considered for award of a contract to perform minor construction work expanding specialty care capabilities. The attachment provides technical drawings of the project scope. Interested parties should review all solicitation documents for detailed requirements and instructions for proposal submission.

View the file

Other files

File Type Posted
Technical Questions - FINAL - Tampa 9-22-23.pdf PDF
2226 - ASI 1- Technical Clarifications - 08-31-23 - Part 1.pdf PDF
2226 - ASI 1- Technical Clarifications - 08-31-23 - Part 2.pdf PDF
0941.2300130.0000- AA-1 - 100% SUBMITTAL JAMES HALEY VETERANS HOSPITAL AA-1.pdf PDF
GEO_James_Haley_Veterans_Hospital_Heliport_-_AES.PDF PDF
Building 1- Life Safety Plans- 4-11-13 FOR REFERENCE ONLY - Part 1.pdf PDF
Building 1- Life Safety Plans- 4-11-13 FOR REFERENCE ONLY - Part 2.pdf PDF
36C77623B0016 0004.pdf PDF
James Haley Veterans Hospital - Record Drawings 2.pdf PDF
James Haley Veterans Hospital - Record Drawings 1.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 9-15-23.pdf PDF
36C77623B0016 0003.pdf PDF
36C77623B0016 0002.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 8-25-23.pdf PDF
Site Visit Sign-in Sheet - Tampa 8-15-23.pdf PDF
36C77623B0016 0001.pdf PDF
ATTACHMENT 14 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 15 - Site Visit Instructions.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 1-13-23.pdf PDF
ATTACHMENT 10 - Drawings - Part 7.pdf PDF
ATTACHMENT 1 - Specifications - Volume 1.pdf PDF
ATTACHMENT 5 - Drawings - Part 2.pdf PDF
36C77623B0016 - 8-7-23.pdf PDF
ATTACHMENT 8 - Drawings - Part 5.pdf PDF
ATTACHMENT 12 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 6 - Drawings - Part 3.pdf PDF
ATTACHMENT 11 - Drawings - Part 8.pdf PDF
ATTACHMENT 7 - Drawings - Part 4.pdf PDF
ATTACHMENT 4 - Drawings - Part 1.pdf PDF
ATTACHMENT 3 - Specifications - Volume 3 - Reference Only.pdf PDF
ATTACHMENT 2 - Specifications - Volume 2.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HALL

BI-PLANE

IR PROCEDURE ROOM

EQUIP.

ROOM

IRMS

EQUIP

CONTROL

ROOM

SCRUB

AREA

SINGLE

PLANE IR PROCEDURE ROOM

EQUIP.

ROOM

HOLDING

ROOM

HOLDING

ROOM

HOLDING

ROOM

HOLDING

ROOM HALL

STAFF

RESTROOM

NURSE

RESTROOM

REST

ROOM

CONSULT

HALL

EQUIP.

STOR.

OFFICE

TEAM

ROOM

CLEAN

STERILE

HALL

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

FIRST FLOOR MECHANICAL PLAN - HYDRONIC

AutoCAD SHX Text N.8

AutoCAD SHX Text U

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

CAV-1-6

AutoCAD SHX Text

CAV-1-5

AutoCAD SHX Text

CAV-1-4

AutoCAD SHX Text

CAV-1-11

AutoCAD SHX Text

CAV-1-9

AutoCAD SHX Text

CAV-1-10

AutoCAD SHX Text

CAV-1-8

AutoCAD SHX Text C1-60-1

AutoCAD SHX Text 1B-02

AutoCAD SHX Text 1B-02A

AutoCAD SHX Text 1B-03

AutoCAD SHX Text 1B-06

AutoCAD SHX Text 1B-05

AutoCAD SHX Text 1B-04

AutoCAD SHX Text 1B-08

AutoCAD SHX Text 1B-07

AutoCAD SHX Text 1B-09

AutoCAD SHX Text 1B-010

AutoCAD SHX Text 1B-011

AutoCAD SHX Text 1B-013

AutoCAD SHX Text C1-61-1

AutoCAD SHX Text 1B-016

AutoCAD SHX Text 1B-023

AutoCAD SHX Text 1B-014

AutoCAD SHX Text 1B-015

AutoCAD SHX Text 1B-017

AutoCAD SHX Text C1-62-1

AutoCAD SHX Text 1B-019

AutoCAD SHX Text 1B-018

AutoCAD SHX Text 1B-020

AutoCAD SHX Text 1B-021

AutoCAD SHX Text 1B-022

AutoCAD SHX Text C1-63-1

AutoCAD SHX Text

CAV-1-7

AutoCAD SHX Text

4" CHWS TO AHU-G-1

AutoCAD SHX Text

4" CHWR TO P-1 & P-2 & P-2P-2

AutoCAD SHX Text

2" HWS UP TO RTU-1-1RTU-1-1

AutoCAD SHX Text

4" CHWR & CHWS UP TO/FROM ROOF

AutoCAD SHX Text

2 1/2" HWS & HWR TO/FROM GROUND FLOOR

AutoCAD SHX Text

2" HWS & HWR

AutoCAD SHX Text

3" CHWS & CHWR

AutoCAD SHX Text

3" CHWS & CHWR TO/FROM RTU-1-1RTU-1-1

AutoCAD SHX Text

2" HWR FROM TO RTU-1-1RTU-1-1

AutoCAD SHX Text

4" CHWR FROM BELOW

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

1 1/4" HWS & HWR

AutoCAD SHX Text

1 1/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

1 1/2" HWS & HWR

AutoCAD SHX Text

1" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

2" HWS & HWR

AutoCAD SHX Text

2" HWS & HWR

AutoCAD SHX Text

OFFSET IN VERTICAL AS REQUIRED

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text N

AutoCAD SHX Text 0'

AutoCAD SHX Text

GRAPHIC SCALE 1/4" = 1'-0"

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

FIRST FLOOR MECHANICAL PLAN - HYDRONIC

AutoCAD SHX Text

MH302

AutoCAD SHX Text

NAE and ADS NETWORK RISER

NAE-1

LOCATION: ?????

IP ADDRESS: ?????

MS/TP FC-BUS A

(SEE INSTALLATION DETAIL FOR

RECOMMENDED WIRE TYPE)

ETHERNET

REPEATER

Server Monitor

ADS Server

METASYS NETWORK LAYOUT

THIS DRAWING SHOWS THE OVERALL NETWORK LAYOUT. SEE THE INDIVIDUAL NAE/

NCE RISER DRAWING(S) FOR MORE SPECIFIC DEVICE DETAILS. IT IS ASSUMED THAT

THE ETHERNET SHOWN IS THE CUSTOMERS ETHERNET BACKBONE. NO ADDITIONAL

SWITCHES, ROUTERS, FIREWALLS, ETC ARE PROVIDED.

AREA A

CONSTANT VOLUME BOX POINTS LISTVARIABLE VOLUME BOX POINTS LIST

HOT WATER HEAT EXCHANGER

VARIABLE & CONSTANT VOLUME AHU

CHILLED WATER POINTS LIST

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text

MH401

CHILLED WATER FLOW DIAGRAM

CHWS CHILLER LAYOUT

Chilled Water Sequence

SYSTEM ENABLE: THE COOLING SYSTEM WILL AUTOMATICALLY START THE SPACE TEMP CALLS FOR

COOLING TO BE ENABLED

CHILLER CONTROL: THIS SYSTEM CONSISTS OF ONE CHILLER.

CHILLED WATER PUMP CONTROL: WHEN ENABLED, THE PUMP FOR THE CHILLER WILL BE STARTED. IF

THE PUMP STATUS DOES NOT MATCH THE COMMAND, AN ALARM WILL BE GENERATED AND THE CHILLER

WILL BE STOPPED. UPON LOSS OF STATUS, THE PUMP WILL RESTART AFTER THE SYSTEM RESET IS

ACTIVATED. AFTER THE CHILLER IS COMMANDED OFF, THE PUMP WILL CONTINUE TO RUN FOR A SHORT

TIME TO ALLOW THE EQUIPMENT TO COAST DOWN.

PRIMARY CHILL WATER LOOP PRESSURE CONTROL: WHEN A PUMP STATUS IS VERIFIED, THE PUMP

WILL BE MODULATED TO MAINTAIN THE SYSTEM DIFFERENTIAL PRESSURE OF THE SYSTEM. IF THE

PRIMARY FLOW FALLS BELOW THE MINIMUM FLOW SETPOINT THE SYSTEM BYPASS VALVE WILL

MODULATE OPEN TO PROVIDE MORE FLOW THRU THE CHILLER.

ADDITIONAL POINTS MONITORED BY THE FMS:

· CHILLER n FLOW (CHn-F)

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

2 POS. NC

AutoCAD SHX Text

2 POS. NC

AutoCAD SHX Text

2 POS. NC

AutoCAD SHX Text

2 POS. NC

AutoCAD SHX Text

2 POS. NO

AutoCAD SHX Text

2 POS. NO

AutoCAD SHX Text

MOD

AutoCAD SHX Text

MOD

AutoCAD SHX Text

MOD

AutoCAD SHX Text

CH-1 132 GPM

AutoCAD SHX Text

AHU-G-1 47.4 GPM

AutoCAD SHX Text

TO CHILLER PLANT

AutoCAD SHX Text

RTU-1-1 84.5 GPM

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 3"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NOTE: SEE COIL, PUMP & CHILLER DETAIL FOR ADDITIONAL VALVES

AutoCAD SHX Text

PCHWP1-C

AutoCAD SHX Text

PCHWP1-S

AutoCAD SHX Text

PCHWP2-C

AutoCAD SHX Text

PCHWP2-S

AutoCAD SHX Text

CH1-EN

AutoCAD SHX Text

CHWS

AutoCAD SHX Text

CHWR

AutoCAD SHX Text

CHILLER 1 CONTROL

AutoCAD SHX Text

CABINET

AutoCAD SHX Text H

AutoCAD SHX Text L

AutoCAD SHX Text

CHW-DP

AutoCAD SHX Text

PCHWP1

AutoCAD SHX Text

PCHWP2

AutoCAD SHX Text

PCHW-F

AutoCAD SHX Text

COMP

AutoCAD SHX Text

EVAP

AutoCAD SHX Text

CHILLER 1

AutoCAD SHX Text

CH1CHW-F

AutoCAD SHX Text

CH1-%%%FLA

AutoCAD SHX Text

PCHWP1

AutoCAD SHX Text

VFD

AutoCAD SHX Text

PCHWP2

AutoCAD SHX Text

VFD

AutoCAD SHX Text

CHWBYPV-O

AutoCAD SHX Text

PCHWP2-O

AutoCAD SHX Text

PCHWP1-O

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text

MH402

HW HEAT EXCHANGE HEAT EXCHANGER LAYOUT

Hot Water System (Heat Exchanger) Sequence

SYSTEM ENABLE: THE HEATING SYSTEM WILL AUTOMATICALLY START WHEN THE SYSTEM ENABLE IS

"ON". WHEN THE SYSTEM ENABLE IS "OFF", THE HEATING SYSTEM WILL BE DISABLED.

HEAT EXCHANGER CONTROL: THIS SYSTEM CONSISTS OF TWO STEAM HEAT EXCHANGERS. TWO

SEQUENCED STEAM INLET VALVES WILL MODULATE IN SEQUENCE TO MAINTAIN THE DESIRED HOT

WATER SUPPLY TEMPERATURE TO SETPOINT AS RESET BY THE OUTDOOR AIR TEMPERATURE.

HOT WATER PUMP CONTROL: WHEN ENABLED, A PUMP FOR EACH OPERATING HEAT EXCHANGER WILL

BE STARTED. WHEN AN ADDITIONAL PUMP IS REQUIRED, THE PUMP WITH THE LOWEST RUNTIME TOTAL

SHALL BE ENABLED TO RUN. IF THE PUMP STATUS DOES NOT MATCH THE COMMAND, AN ALARM WILL

BE GENERATED AND THE PUMP WILL BE STOPPED. UPON LOSS OF STATUS, THE PUMP WILL RESTART

AFTER THE SYSTEM RESET IS ACTIVATED.

PHWP1-C

PHWP1-S

PHWP2-C

PHWP2-S

NC

HX1V2-O

2/3

STEAM

NC

HX2V2-O

2/3

HWS

HWR

PHWS-T

PHWP2

HX-1

NC

HX1V1-O

1/3

COND

HX-2

STEAM

NC

HX2V1-O

1/3

COND

PHWP1

PHWP2 STARTER

PHWP1 STARTER

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text

MH403

CONSTANT VOLUME AHU FLOW LAYOUT

Constant Volume AHU Sequence

SUPPLY FAN CONTROL: THE SUPPLY FAN WILL BE STARTED BASED ON OCCUPANCY SCHEDULE. WHEN

THE SUPPLY FAN STATUS INDICATES THE FAN STARTED, THE CONTROL SEQUENCE WILL BE ENABLED.

THE SUPPLY FAN WILL MODULATE TO MAINTAIN THE CONSTANT AIRFLOW BASED ON DISCHARGE STATIC

PRESSURE. UPON A LOSS OF AIRFLOW, THE SYSTEM WILL AUTOMATICALLY RESTART. UNIT AIRFLOW

WILL BE MONITORED VIA A FAN MOUNTED PIZO.

MINIMUM OA CONTROL: THE MINIMUM OA INJECTION FAN WILL OPERATE WHEN THE UNIT IS IN

OCCUPIED MODE, THE MINIMUM OA DAMPER WILL OPEN PRIOR TO STARTING THE FAN.

TEMPERATURE CONTROL: THE DISCHARGE AIR TEMPERATURE SETPOINT WILL BE RESET AS THE ZONE

TEMPERATURE CHANGES.

OCCUPIED MODE: THE OCCUPANCY MODE WILL BE CONTROLLED VIA A NETWORK INPUT. THE

OCCUPANCY MODE CAN ALSO BE OVERRIDDEN BY A NETWORK INPUT OR A TEMPORARY OCCUPANCY

SWITCH ON THE ZONE TEMPERATURE SENSOR

UNOCCUPIED MODE: THE UNIT WILL REMAIN OFF DURING UNOCCUPIED PERIODS.

COOLING COIL: THE COOLING COIL WILL MODULATE TO MAINTAIN THE TEMPERATURE SETPOINT.

WHEN THE UNIT IS SHUTDOWN, THE COOLING COIL WILL BE COMMANDED TO A PRESET POSITION

SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE

SETPOINT. UPON A LOSS OF AIRFLOW, THE COOLING COIL WILL BE OFF.

ADDITIONAL POINTS MONITORED BY THE FMS:

· MINIMUM OUTDOOR AIR FAN STATUS (MOAF-S)

· MINIMUM OUTDOOR AIR DAMPER STATUS (MOAD-S)

· DISCHARGE AIR VELOCITY PRESSURE (DA-VP)

· RETURN AIR TEMPERATURE (RA-T)

· RETURN AIR HUMIDITY (RA-H)

· ZONE HUMIDITY (ZN-H)

· PREFILTER DIFF PRESSURE (PFILT-DP)

· FINAL FILTER DIFFERENTIAL PRESSURE (FFILT-DP)

· LOW TEMPERATURE ALARM (LT-A)

MOAF-C

MOAF-S

SDR-4

MOAF STARTER

MIN

OA

SUPPLY

RETURN

CLG-O

C

C

FFILT-DP

PFILT-DP

OA

EA

DA

RA

SF-C

SF-S

SDR-1

DA-T

SF VFD

LT-A

RA-T

RA-H

DA-VP

DAPHI-A

L H

DA1-P

LH

LOCATED 2/3 DOWN THE

LONGEST DUCT RUN

N C

MOAD-C

SF-O

MOAD-S

ZN-T

ZN-H

WC-ADJ

ZN-TOCC

H N24 VAC

SDR-1LT-A

FOR WIRING OF SAFETY

SHUTDOWN RELAY (SDR-N)

CONTACTS, SEE

DESIGNATION ON STARTER/

VFD DETAIL.

Safety Shutdown Relay Coil Wiring Detail

FIRE ALARM

SHUTDOWN

DAPHI-A

(If used)

SDR-4

DA-TDA-VP

DPR-O

HWS

HWR

H

C

B

C A

HTG-O

ZN-T

WC-ADJ

ZN-TOCC

SA DA

CONSTANT VOLUME FLOW LAYOUT

Constant Volume Terminal Box Sequence

OCCUPIED MODE: WHEN THE ZONE TEMPERATURE IS BETWEEN THE OCCUPIED HEATING AND COOLING

SETPOINTS (INSIDE OF THE BIAS). ON A DROP IN ZONE TEMPERATURE BELOW THE HEATING SETPOINT, THE REHEAT COIL WILL BE USED TO MAINTAIN THE ZONE TEMPERATURE.

DISCHARGE AIR TEMP SENSOR: A DISCHARGE AIR TEMP SENSOR IS PROVIDED ON EACH BOX FOR

MONITORING PURPOSES.

OCCUPANCY CONTROL: A TEMPORARY OCCUPANCY BUTTON ON THE ZONE SENSOR WILL PLACE THE

BOX IN OCCUPIED MODE FOR AN ADJUSTABLE LENGTH OF TIME.

UNIT ENABLE: A NETWORK UNIT ENABLE SIGNAL WILL CONTROL THE MODE OF THE BOX.

NETWORK WARMUP-COOLDOWN: WARMUP-COOLDOWN MODES WILL BE ACTIVATED BY A NETWORK

COMMAND.

ADDITIONAL POINTS MONITORED BY THE FMS:

· ZONE HUMIDITY (ZN-H)

BACnet Input from

Lighting Control

System

LIGHTING CONTROL

INTEGRATION

DDC Control System shall integrate Lighting Control via

BACnet.

Lighting System Control and display will reside on the DDC front end

LIGHTING CONTROL INTEGRATION

AHU-G-1 FLOW DIAGRAM (RTU-1-1 SIMILAR)

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text

MH404

Electrical Legend, Schedules, Details, and Demolition Site Plan

NOTES:

ELECTRICAL LEGEND

NAMIR A. HADDAD P.E.

LICENSE NO. 31967

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290 JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-19-22 PHYSICAL AND ELECTRICAL SECURITY UPDATE

GENERAL NOTES:

NURSE CALL SYSTEM

FIRE ALARM

GROUND FLOOR DEMOLITION PLAN - ELECTRICAL

DEMOLITION NOTES:

SECURITY LEGEND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING BUILDING 19

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING BUILDING 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING SHACK

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING CANOPY

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-83

AutoCAD SHX Text

APPROXIMATE EXISTING LOCATION OF AHU'S

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-83

AutoCAD SHX Text

UP

AutoCAD SHX Text

LOUVER

AutoCAD SHX Text

EL. 38.63

AutoCAD SHX Text

UP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

SCI

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

MACHINERY

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

BELOW

AutoCAD SHX Text

METAL

AutoCAD SHX Text

DOCK

AutoCAD SHX Text

RAILING

AutoCAD SHX Text

STOR.

AutoCAD SHX Text

EL. 43.22

AutoCAD SHX Text

PASS-THRU

AutoCAD SHX Text

WINDOW

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

HANDRAILS

AutoCAD SHX Text

EI100

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text EXISTING A/C UNITS TO BE RELOCATED. PROVIDE ALL CONDUITS, CABLES, AND ALL OTHER REQUIRED MATERIALS FOR A COMPLETE RELOCATION OF ELECTRICAL. EXISTING CONDENSING UNITS TO BE RELOCATED UNDER SEPARATE CONTRACT. EXISTING A/C UNITS TO BE REMOVED. REMOVE CABLES AND SURFACE MOUNTED CIRCUITS. EXISTING BUILDING ELECTRICAL SERVICE TO BE REMOVED. PULL ELECTRICAL SERVICE BACK TO SOURCE AT SWITCHGEAR. EXISTING ELEVATOR AND ASSOCIATED ELECTRICAL TO BE REMOVED. PULL ELECTRICAL SERVICE BACK TO SOURCE AT SWITCHGEAR AND REMOVE EXPOSED CONDUITS. EXISTING SHACK. REMOVE ALL ASSOCIATED ELECTRICAL. PULL ELECTRICAL SERVICE BACK TO SOURCE AND REMOVE EXPOSED CONDUITS. EXISTING CANOPY AND ASSOCIATED ELECTRICAL TO BE REMOVED. PULL ELECTRICAL BACK TO SOURCE AND REMOVE EXPOSED CONDUITS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (LIFE SAFETY BRANCH).

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NAH

AutoCAD SHX Text

WH

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revision to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text

1. ALL CONDUITS SHALL BE CONCEALED IN WALL, CEILING, OR UNDERGROUND. SURFACE CONDUITS ALL CONDUITS SHALL BE CONCEALED IN WALL, CEILING, OR UNDERGROUND. SURFACE CONDUITS WILL BE PERMITTED IN ELECTRICAL AND MECHANICAL ROOMS ONLY. CONTRACTOR SHALL CUT EXISTING WALLS TO CONCEAL CONDUITS. REPAIR ALL WALLS TO ITS ORIGINAL CONDITION AFTER INSTALLING CONDUIT OR OUTLET BOXES. 2. DUPLEX RECEPTACLES ARE PROVIDED IN MECHANICAL ROOMS TO POWER ENERGY MANAGEMENT DUPLEX RECEPTACLES ARE PROVIDED IN MECHANICAL ROOMS TO POWER ENERGY MANAGEMENT CONTROL BOXES. COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATION OF BOXES. PROVIDE 3 #12 WIRES IN 3/4" CONDUIT FROM BOX TO ASSOCIATED DUPLEX RECEPTACLES. 3. SEE ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. SEE ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. 4. CONNECT MOTORIZED DAMPERS TO CLOSEST 120V RECEPTACLE CIRCUIT. COORDINATE WITH CONNECT MOTORIZED DAMPERS TO CLOSEST 120V RECEPTACLE CIRCUIT. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATION. 5. INTERLOCK EXHAUST FAN WITH RESPECTIVE AHU. PROVIDE REQUIRED #12 WIRE IN CONDUIT. INTERLOCK EXHAUST FAN WITH RESPECTIVE AHU. PROVIDE REQUIRED #12 WIRE IN CONDUIT. SEE MECHANICAL DRAWINGS, FAN SCHEDULE, FOR INTERLOCK. PROVIDE TRANSFORMER AT LOCATION OF FAN TERMINAL BOX. COORDINATE WITH HVAC CONTRACTOR. 6. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ADEQUATE WORKING SPACE FOR ALL PANELBOARDS, MOTOR STARTERS AND FUSED DISCONNECT SWITCH. WORKING SPACE SHALL BE CLEAR OF PIPES AND DUCTS. ANY CODE VIOLATION AS A RESULT OF LACK OF COORDINATION SHALL BE RECTIFIED AT NO COST TO OWNER. 7. PROVIDE NEW CEILING TILES SAME TYPE AS EXISTING TO REPLACE DAMAGED TILES AS A RESULT PROVIDE NEW CEILING TILES SAME TYPE AS EXISTING TO REPLACE DAMAGED TILES AS A RESULT OF CONTRACTOR OPERATION. 8. FIREPROOF ALL WALL AND FLOOR PENETRATIONS. AT COMPLETION OF PROJECT PROVIDE A FIREPROOF ALL WALL AND FLOOR PENETRATIONS. AT COMPLETION OF PROJECT PROVIDE A LETTER CERTIFYING THAT ALL WALL OPENINGS HAVE BEEN RESTORED AND VOIDS FILLED WITH FIRE RATED COMPOUND BY CONTRACTOR. 9. RESTORE DISTURBED WALLS TO ITS ORIGINAL CONDITION. FINISH AND PAINT DAMAGED AREAS, RESTORE DISTURBED WALLS TO ITS ORIGINAL CONDITION. FINISH AND PAINT DAMAGED AREAS, PAINT SHALL MATCH EXISTING. 10. PVC CONDUITS WILL BE PERMITTED IN UNDERGROUND APPLICATIONS EXCEPT FEEDERS OR PVC CONDUITS WILL BE PERMITTED IN UNDERGROUND APPLICATIONS EXCEPT FEEDERS OR BRANCH CIRCUITS TO PATIENT CARE AREAS. 11. ALL EXTERIOR WALL MOUNTED JUNCTION BOXES SHALL BE NEMA-3R. ALL EXTERIOR WALL MOUNTED JUNCTION BOXES SHALL BE NEMA-3R. 12. PROVIDE UPDATED, TYPED PANELBOARD SCHEDULES FOR ALL THE ELECTRICAL PANELS LOCATED PROVIDE UPDATED, TYPED PANELBOARD SCHEDULES FOR ALL THE ELECTRICAL PANELS LOCATED IN THE ELECTRICAL ROOMS. PANEL SCHEDULES SHALL REFLECT THE CORRECT ROOM NAMES AND NUMBERS AND ANY CIRCUIT CHANGES MADE IN THE FIELD. 13. ROOF PENETRATIONS TO ROOF MOUNTED EQUIPMENT MUST BE WITHIN EQUIPMENT CURBS. ROOF PENETRATIONS TO ROOF MOUNTED EQUIPMENT MUST BE WITHIN EQUIPMENT CURBS. STUB-UP TO ABOVE ROOF THRU SIDE OF CURB FOR EXTERNAL EQUIPMENT CONNECTIONS (TYPICAL). DO NOT RUN CONDUIT IN AIR SUPPLY OR RETURN AIR OPENINGS. 14. PROVIDE CONDUITS FOR ALL H.V.A.C. SYSTEM CONTROL WIRING. PROVIDE 3/4" CONDUIT FROM PROVIDE CONDUITS FOR ALL H.V.A.C. SYSTEM CONTROL WIRING. PROVIDE 3/4" CONDUIT FROM EACH A.H.U. UNIT TO ASSOCIATED THERMOSTAT. PROVIDE 3/4" CONDUIT WIRE AND CONDUITS FOR EXHAUST FANS CONTROL. SEE MECHANICAL DRAWINGS FOR LOCATION OF THERMOSTATS AND MECHANICAL EQUIPMENT. 15. ALL CONDUITS PENETRATING A SMOKE WALL SHALL BE RIGID STEEL AND HAVE 3" CLEARANCE ALL CONDUITS PENETRATING A SMOKE WALL SHALL BE RIGID STEEL AND HAVE 3" CLEARANCE ALL AROUND THE CONDUIT TO ANY OBSTRUCTION TO ALLOW FOR PROPER SEALING OF PENETRATIONS. ALL NURSE CALL STATIONS MOUNTED ON SMOKE WALLS SHALL HAVE SEPARATE DRYWALL ENCLOSURES ON ALL SIDES AND BACK. CONDUITS SHALL SMOKE WALLS SHALL HAVE SEPARATE DRYWALL ENCLOSURES ON ALL SIDES AND BE SUPPORTED WITHIN 12" FROM BOTH SIDES OF SMOKE WALL (TYPICAL). 16. ALL PANELBOARDS, DISCONNECT SWITCHES AND COMBINATION MOTOR STARTERS SHALL HAVE A ALL PANELBOARDS, DISCONNECT SWITCHES AND COMBINATION MOTOR STARTERS SHALL HAVE A MINIMUM OF 3'-0" WORKING CLEARANCE FOR 120/208V, AND 4'-0" WORKING CLEARANCE FOR 277/480V. 17. FOR 120V CIRCUITS, PROVIDE # 12 AWG FOR ANY CIRCUIT OVER 60'-0" IN LENGTH AND #10 FOR 120V CIRCUITS, PROVIDE # 12 AWG FOR ANY CIRCUIT OVER 60'-0" IN LENGTH AND #10 AWG FOR ANY CIRCUIT OVER 160'-0" ON A 20A CIRCUIT BREAKER. 18. ALL RECEPTACLES AND SWITCHING FOR DEVICES CONNECTED TO THE EMERGENCY SYSTEM SHALL ALL RECEPTACLES AND SWITCHING FOR DEVICES CONNECTED TO THE EMERGENCY SYSTEM SHALL BE RED IN COLOR, TYPICAL THROUGHOUT. COVERPLATES SHALL BE STAINLESS STEEL AND ENGRAVED IN RED COLOR "PANEL & CIRCUIT No." 19. ALL BRANCH CIRCUITS SERVING PATIENT CARE AREAS SHALL BE IN METAL RACEWAY. PVC ALL BRANCH CIRCUITS SERVING PATIENT CARE AREAS SHALL BE IN METAL RACEWAY. PVC CONDUIT OR MC CABLE WILL NOT BE ALLOWED IN PATIENTS CARE AREAS. 20. INSTALL A GREEN EQUIPMENT GROUND WIRE IN ALL CONDUITS DEVICES AND EQUIPMENT INSTALL A GREEN EQUIPMENT GROUND WIRE IN ALL CONDUITS DEVICES AND EQUIPMENT BONDING SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. GROUNDING WIRES SHALL BE SIZED IN ACCORDANCE TO N.E.C. 21. ALL FIRE ALARM AND EMERGENCY POWER JUNCTION BOXES, COVERS AND CONDUITS IN CEILING ALL FIRE ALARM AND EMERGENCY POWER JUNCTION BOXES, COVERS AND CONDUITS IN CEILING SPACE AND ELECTRICAL ROOMS SHALL BE PAINTED AS FOLLOWS: CRITICAL BRANCH - ORANGE LIFE SAFETY BRANCH - YELLOW EQUIPMENT BRANCH - GREEN FIRE ALARM - RED 22. FLEXIBLE STEEL CONDUIT MAY BE USED FOR CONNECTIONS TO RECESSED LIGHTING FIXTURES FLEXIBLE STEEL CONDUIT MAY BE USED FOR CONNECTIONS TO RECESSED LIGHTING FIXTURES (MAXIMUM LENGTH 6-FEET) AND TO MOTORS (MAXIMUM LENGTH 18 INCHES). ALL FLEXIBLE CONDUIT CONNECTIONS SHALL BE PROVIDED WITH A GREEN INSULATED GROUND WIRE. A TOTAL OF SIX FEET MAXIMUM BETWEEN THE BRANCH PANELBOARD AND THE LAST OUTLET ON ANY CIRCUIT IS ACCEPTABLE. THE USE OF FLEXIBLE CONDUIT SHALL BE LIMITED TO JUNCTION BOX TO LIGHTING FIXTURES, JUNCTION BOX TO VIBRATING EQUIPMENT (MOTOR, FAN, ETC.) AND SHALL BE MINIMIZED AND ONLY USED WHERE ABSOLUTELY REQUIRED. 23. PROVIDE GREEN INSULATION GROUND FOR ALL GROUNDING TYPE RECEPTACLES AND EQUIPMENT PROVIDE GREEN INSULATION GROUND FOR ALL GROUNDING TYPE RECEPTACLES AND EQUIPMENT OF ALL VOLTAGES. IN ADDITION TO GROUNDING STRAP CONNECTION TO METALLIC OUTLET BOXES, A SUPPLEMENTAL GROUNDING WIRE AND SCREW EQUAL TO RACO NO. 983 SHALL BE PROVIDED TO CONNECT RECEPTACLE GROUND TERMINAL TO THE BOX. 24. PERFORM GROUND INTEGRITY TEST AND EQUIPONTETIAL IN ACCORDANCE WITH NEC PERFORM GROUND INTEGRITY TEST AND EQUIPONTETIAL IN ACCORDANCE WITH NEC 517-11,13,14, AND 16 AND NFPA-99, CHAPTER 3.5. SUBMIT (3) THREE SIGNED COPIES OF REPORT. EQUIPOTENTIAL GROUNDING TEST DOCUMENTATION AND DEMONSTRATION OF THE EQUIPOTENTIAL TEST SHALL BE PROVIDED AT THE FINAL AHCA SURVEY. USE A HAMPDEN #MOV TESTER OR EQUAL. TECHNICIAN AND CALIBRATED TESTER SHALL BE PRESENT AT AHCA FINAL INSPECTION. 25. THE SIZE OF WIRING, CONDUIT, DISCONNECT AND FUSES FOR HVAC EQUIPMENT IS BASED ON THE SIZE OF WIRING, CONDUIT, DISCONNECT AND FUSES FOR HVAC EQUIPMENT IS BASED ON THE MECHANICAL BASIS OF DESIGN. COORDINATE WITH MECHANICAL CONTRACTOR VERIFY ELECTRICAL REQUIREMENTS FOR EQUIPMENT SUPPLIED. IF THE BASIS OF DESIGN IS NOT USED. THE CONTRACTOR SHALL RESIZE THESE ITEMS PER THE NATIONAL ELECTRICAL CODE AND MANUFACTURER'S RECOMMENDATIONS AND SHALL SHALL SUBMIT THIS DATA WITH THE HVAC SUBMITTAL FOR APPROVAL. 26. PROVIDE ALL THE REQUIRED WIRING AND CONDUIT TO CONNECT MOTORIZED DAMPERS AND PROVIDE ALL THE REQUIRED WIRING AND CONDUIT TO CONNECT MOTORIZED DAMPERS AND INTERLOCK HVAC EQUIPMENT. SEE MECHANICAL FOR EXACT PAIRING. 27. VERIFY WITH OWNER FOR EQUIPMENT'S ELECTRICAL CHARACTERISTICS PRIOR TO ROUGH IN. VERIFY WITH OWNER FOR EQUIPMENT'S ELECTRICAL CHARACTERISTICS PRIOR TO ROUGH IN. 28. PROVIDE NURSE CALL DOCUMENTATION AND CERTIFICATIONS. NURSE CALL TECHNICIAN SHALL BE PROVIDE NURSE CALL DOCUMENTATION AND CERTIFICATIONS. NURSE CALL TECHNICIAN SHALL BE PRESENT AT FINAL INSPECTION. 29. PROVIDE DUCT SMOKE DETECTOR SENSITIVITY TEST REPORTS AND FIRE ALARM CERTIFICATION PROVIDE DUCT SMOKE DETECTOR SENSITIVITY TEST REPORTS AND FIRE ALARM CERTIFICATION DOCUMENTS. TEST REPORT SHALL BE AVAILABLE FOR INSPECTIONS REVIEW AT FINAL SURVEY. FIRE ALARM TECHNICIAN SHALL BE PRESENT AT FINAL INSPECTION. 30. VERIFY THE OPERATION AND FUNCTION OF EXISTING GENERATOR. ALL FUNCTIONS SHALL MEET VERIFY THE OPERATION AND FUNCTION OF EXISTING GENERATOR. ALL FUNCTIONS SHALL MEET NFPA. A GENERATOR TECHNICIAN SHALL BE PRESENT AT FINAL INSPECTION TO DEMONSTRATE THE AVAILABILITY OF EMERGENCY POWER. 31. CONTRACTOR SHALL INCLUDE AS PART OF BASE BID COST FOR ADDITIONAL ELECTRICAL WORK CONTRACTOR SHALL INCLUDE AS PART OF BASE BID COST FOR ADDITIONAL ELECTRICAL WORK AS MAY BE NEEDED ON THIS PROJECT TO INCLUDE (3) FIRE ALARM SPEAKER STROBES, (3) FIRE ALARM DUCT DETECTORS, (3) TYPE 'E' LIGHTING FIXTURES, (4) DATA OUTLETS (5 CAT6 JACKS EACH), AND (8) DUPLEX RECEPTACLES. INCLUDE UP TO 150 FEET CONDUIT AND ASSOCIATED CABLES PER OUTLET/DEVICE. IN ADDITION TO ABOVE WORK PROVIDE 600 FEET OF 3/4"CONDUIT AND 2000 FEET OF THHN #8 CABLE. ALLOWANCES FOR ADDITIONAL WORK SHALL INCLUDE REQUIRED BOXES, FITTINGS, SUPPORT, DRILLING OF WALLS/BEAMS, PAINTING, REPAIRING OF EXISTING SURFACES, FIRE STOPPING AND ALL HARDWARE AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. ALLOWANCES SHALL ALSO INCLUDE ALL REQUIRED PROGRAMMING AND TESTING. LOCATION OF DEVICES TO BE DETERMINED DURING CONSTRUCTION. UNUSED DEVICES SHALL BE DELIVERED TO THE VA HOSPITAL AS SPARE PARTS. 32. LIGHTING CONTROL COMMISSIONING: PROVIDE FUNCTIONAL TESTING FOR EACH SPACE. PROVIDE LIGHTING CONTROL COMMISSIONING: PROVIDE FUNCTIONAL TESTING FOR EACH SPACE. PROVIDE TEST REPORT FOR REVIEW NO FEWER THAN 5 DAYS PRIOR TO THE FINAL INSPECTION. 33. ALL NORMAL POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWEDER ALL NORMAL POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWEDER COATED IVORY AND ENGRAVED WITH CIRCUIT NUMBER. ALL EMERGENCY POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWEDER COATED RED AND ENGRAVED WITH CIRCUIT NUMBER. 34. PROVIDE EZ PATH FIRE PROOFING FOR CABLE TRAYS PENETRATING FIRE RATED WALL. SIZE PROVIDE EZ PATH FIRE PROOFING FOR CABLE TRAYS PENETRATING FIRE RATED WALL. SIZE BLOCKS FOR QUANTITY OF CAT6 CABLES PLUS 20% CAPACITY. 35. PROVIDE 120V, POWER TO ALL ELECTRICALLY OPERATED FLUSH VALVES OR WATER VALVE. PROVIDE 120V, POWER TO ALL ELECTRICALLY OPERATED FLUSH VALVES OR WATER VALVE. COORDINATE WITH PLUMBING CONTRACTOR.

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE WITH BATTERY BACK-UP, CONNECTED TO CRITICAL BRANCH.

AutoCAD SHX Text

LED LIGHTING FIXTURE - SURFACE MOUNTED.

AutoCAD SHX Text LEDLIGHTING FIXTURE - SURFACE MOUNTED. CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text

LED LIGHTING FIXTURE - SURFACE MOUNTED. CONNECTED ON EMERGENCY POWER

AutoCAD SHX Text

(LIFE SAFETY BRANCH).

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED.

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED. CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED. CONNECTED ON EMERGENCY POWER (LIFE SAFETY BRANCH).

AutoCAD SHX Text EXIT LIGHT - PROVIDE ARROWS AS INDICATED, SHADING DENOTES FACE OPERATION. DO NOT SWITCH.

AutoCAD SHX Text

STAINLESS STEEL COVERPLATE - 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL1221I WITH

AutoCAD SHX Text

LOW VOLTAGE DIMMER SWITCH, IVORY, 46" MOUNTING HEIGHT, U.N.O. WATTSTOPPER MODEL

AutoCAD SHX Text

AS INDICATED ON PLANS WITH STEEL COVER PLATE.

AutoCAD SHX Text

LOW VOLTAGE DIMMER SWITCH, RED, 46" MOUNTING HEIGHT, U.N.O. WATTSTOPPER MODEL

AutoCAD SHX Text

AS INDICATED ON PLANS WITH IVORY STAINLESS STEEL COVER PLATE - CRITICAL POWER.

AutoCAD SHX Text

CEILING MOUNTED LOW VOLTAGE OCCUPANCY SENSOR-WATTSTOPPER #LMDC-100-U.

AutoCAD SHX Text

WATTSTOPPER ELCU-200 EMERGENCY BYPASS. SEE LIGHTING CONTROL DIAGRAMS.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL1221R

AutoCAD SHX Text

WITH STAINLESS STEEL COVERPLATE - CRITICAL POWER - 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

EMERGENCY POWER OFF PUSH BUTTON (EPO).

AutoCAD SHX Text S

AutoCAD SHX Text

CEILING MOUNTED PAGING SPEAKER WITH BACK BOX. PROVIDE WIRES IN CONDUIT.

AutoCAD SHX Text

BEDSIDE NURSE CALL STATION WITH PULL CORD, 42 INCH MOUNTING HEIGHT.

AutoCAD SHX Text N

AutoCAD SHX Text

NURSE CALL DUTY STATION. MOUNTED 54 INCHES ABOVE FLOOR.

AutoCAD SHX Text

BEDSIDE STATION. AUDIO/VIDEO

AutoCAD SHX Text N/C

AutoCAD SHX Text

NURSE CALL MASTER STATION.

AutoCAD SHX Text

NM

AutoCAD SHX Text

CODE BLUE STATION. COORDINATE WITH OWNER FOR MOUNTING HEIGHT.

AutoCAD SHX Text B

AutoCAD SHX Text

EMERGENCY/LAVATORY NURSE CALL STATION WITH PULL CORD

AutoCAD SHX Text E

AutoCAD SHX Text

REACHING TO FLOOR. 42 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

NURSE CALL DOME LIGHT.

AutoCAD SHX Text D

AutoCAD SHX Text

NURSE CALL ZONE LIGHT.

AutoCAD SHX Text Z

AutoCAD SHX Text

EMERGENCY CALL STAFF STATION. 42" MOUNTING HEIGHT.

AutoCAD SHX Text E

AutoCAD SHX Text

NURSE CALL STAFF STATION. 54" MOUNTING HEIGHT.

AutoCAD SHX Text S

AutoCAD SHX Text

WALL MOUNTED PAGING SPEAKER - 9'-0" MOUNTING HEIGHT.

AutoCAD SHX Text

DC

AutoCAD SHX Text

TV

AutoCAD SHX Text

DOOR CONTROL IN CEILING SPACE.

AutoCAD SHX Text CABLE RUNNER MOUNTED AT 24" ABOVE ITR RACKS. PROVIDE CABLE FALL ADAPTER EXTENDED TO ITR.

AutoCAD SHX Text

TOUCHLESS DOOR ENTRY SENSOR.

AutoCAD SHX Text D

AutoCAD SHX Text

CABLE TRAY IN CEILING SPACE.

AutoCAD SHX Text CABLE TV OUTLET - (1) COAXIAL CABLE CONNECTOR, (1) RJ-45 CONNECTOR AND IVORY COVERPLATE.

AutoCAD SHX Text

PROVIDE 3/4" C. TO CEILING SPACE.

AutoCAD SHX Text

MOTOR STARTER WITH DISCONNECT.

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text

LR

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text

LR

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

FLUSH MOUNTED MANUAL FIRE ALARM PULL STATION, 46 INCH MOUNTING HEIGHT.

AutoCAD SHX Text SEMI-FLUSH MOUNTED FIRE ALARM SPEAKER/VISUAL WARNING DEVICE, 86-96 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

DENOTES FIRE ALARM CONTROL PANEL.

AutoCAD SHX Text 110 INDICATES 110 CANDELA STROBE. UTILIZE 75 CANDELA IN SMALL ROOMS AND CORRIDORS.

AutoCAD SHX Text

USE 110 CANDELA IN ROOMS LARGER THAN 30' IN WIDTH OR LENGTH.

AutoCAD SHX Text F.A.C.P.

AutoCAD SHX Text

DENOTES FIRE ALARM ANNUNCIATOR PANEL.

AutoCAD SHX Text F.A.A.P.

AutoCAD SHX Text

(FROM FLOOR TO BOTTOM OF DEVICE)

AutoCAD SHX Text

CEILING MOUNTED SMOKE DETECTOR.

AutoCAD SHX Text

AIR CONDITIONING/HEAT PUMP SHUT DOWN RELAY.

AutoCAD SHX Text

FIRE ALARM SPRINKLER FLOW SWITCH.

AutoCAD SHX Text

FIRE ALARM SPRINKLER VALVE TAMPER SWITCH.

AutoCAD SHX Text SEMI-FLUSH FIRE ALARM VISUAL WARNING DEVICE, WALL MOUNTED. 80-96 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

TS

AutoCAD SHX Text

FS

AutoCAD SHX Text

RL

AutoCAD SHX Text R

AutoCAD SHX Text D

AutoCAD SHX Text

FLUSH WALL MOUNTED DOOR HOLDING DEVICE - 70 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

DH

AutoCAD SHX Text

DRAWING FOR MOUNTING LOCATION AND QUANTITY.

AutoCAD SHX Text

DUCT MOUNTED SMOKE DETECTOR, MOUNTED IN A/C DUCT. SEE MECHANICAL

AutoCAD SHX Text

CEILING. LABEL COVERPLATE TO INDICATE RESPECTIVE A/C UNIT.

AutoCAD SHX Text DUCT MOUNTED SMOKE DETECTOR REMOTE INDICATOR WITH RESET/TEST CAPABILITY, FLUSH MOUNTED IN

AutoCAD SHX Text N

AutoCAD SHX Text

1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. 2. THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN ASSOCIATION WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS-BUILT" DRAWINGS TO THE OWNER, INDICATING ANY SUCH CHANGES. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES OR FIXTURES. 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS MEET CURRENT CODES. REMOVE ALL UNUSED SURFACE MOUNTED CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH REMOVED BUILDING. MAINTAIN DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH REMOVED BUILDING. MAINTAIN EXISTING EQUIPMENT TO REMAIN. SEE DRAWING AD101 AND AD102. 11. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT.

AutoCAD SHX Text

GRAPHIC SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 0'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 6'

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text

WALL MOUNTED CAMERA ROUGH IN

AutoCAD SHX Text

ROUGH IN FOR KEYBOARD DURESS ALARM.

AutoCAD SHX Text

ROUGH IN FOR CARD READER

AutoCAD SHX Text

DB

AutoCAD SHX Text

LMRC-102 DIGITAL DUAL RELAY ROOM CONTROLLER.

AutoCAD SHX Text

LMRC-211 RELAY ON/OFF/0-10V DIMMING ROOM CONTROLLER.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE, 20 AMP, 120/277V, MOTOR RATED, GROUNDING TYPE, MOUNT AT

AutoCAD SHX Text

EQUIPMENT HOUSING.

AutoCAD SHX Text VACANCY SENSOR - SWITCH, 120/277 VOLT, ADJUSTABLE DELAY OFF. WATTSTOPPER #DW-100-IVORY, AutoCAD SHX Text

IVORY STAINLESS STEEL COVERPLATE, 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DUPLEX RECEPTACLE HOSPITAL GRADE- NORMAL POWER - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL

AutoCAD SHX Text

NO. HBL8300I WITH IVORY NO. SS8 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 42" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

HUBBELL NO. HBL8300I WITH IVORY NO. SS82 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DOUBLE DUPLEX RECEPTACLES HOSPITAL GRADE - (2) TWO 20 AMP, 120 VOLT, 3 WIRE GROUNDING, AutoCAD SHX Text SPECIAL PURPOSE RECEPTACLE COMPLETE WITH COVERPLATE. RECEPTACLE TO MATCH EQUIPMENT PLUG.

AutoCAD SHX Text DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER HOSPITAL GRADE, 20 AMP, 120 VOLT, 3 WIRE

AutoCAD SHX Text GROUNDING. HUBBELL NO. GFR8300ITR WITH IVORY STAINLESS STEEL COVERPLATE, 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

"EMERGENCY POWER & CIRCUIT NO." IN RED LETTERS, 18 INCH MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

3 WIRE GROUNDING. HUBBELL NO. GF8300ITR WITH RED STAINLESS STEEL ENGRAVED

AutoCAD SHX Text

HOSPITAL GRADE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A., 120 VOLT,

AutoCAD SHX Text

"EMERGENCY POWER & CIRCUIT NO." IN RED LETTERS, 18 INCH MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

3 WIRE GROUNDING. HUBBELL NO. GF8300ITR WITH RED STAINLESS STEEL PLATE ENGRAVED

AutoCAD SHX Text HOSPITAL GRADE DOUBLE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A., 120 VOLT, AutoCAD SHX Text DUPLEX RECEPTACLE HOSPITAL GRADE - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL HBL8300R WITH RED

AutoCAD SHX Text NO. SS8 COVERPLATE, ENGRAVED "EMERGENCY POWER & CIRCUIT NUMBER" ON CRITICAL BRANCH POWER, 18"

AutoCAD SHX Text

MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

RC

AutoCAD SHX Text

DM

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text TELEPHONE/DATA OUTLET - 4" SQUARE 2 1/8" DEEP JUNCTION BOX WITH 1-GANG EXTENSION RING

AutoCAD SHX Text AND CAT 6 RJ-45 CONNECTORS. NUMBER INDICATE QUANTITY OF RJ-45 JACKS. 18" MOUNTING HEIGHT, AutoCAD SHX Text U.N.O. PROVIDE (QUANTITY EQUAL TO NUMBER OF JACKS) CAT 6 CABLES TO MTR.

This is the start of the file's text. The full file is on GovTribe.