2226 - ASI 1- Technical Clarifications - 08-31-23 - Part 2.pdf

PDF 21 MB Posted

Attached to
Y1DA--Specialty Treatment Expansion (Minor) Construction - Tampa
Solicitation number
36C77623B0016
Issued by

About this file

This document is a technical clarification file related to solicitation number 36C77623B0016 from the Department of Veterans Affairs Technology Acquisition Center Austin for specialty treatment expansion construction services in Tampa. The 21MB file provides additional details on the required construction work, which includes minor renovations and additions to existing specialty treatment spaces. Interested offerors must address specific questions and clarifications in the file when preparing proposals. Proposals are due by September 30, 2023, with award anticipated by the end of October 2023. The set-aside is for verified service-disabled veteran-owned small businesses. The period of performance is 270 days following award.

View the file

Other files

File Type Posted
Technical Questions - FINAL - Tampa 9-22-23.pdf PDF
2226 - ASI 1- Technical Clarifications - 08-31-23 - Part 1.pdf PDF
0941.2300130.0000- AA-1 - 100% SUBMITTAL JAMES HALEY VETERANS HOSPITAL AA-1.pdf PDF
GEO_James_Haley_Veterans_Hospital_Heliport_-_AES.PDF PDF
Building 1- Life Safety Plans- 4-11-13 FOR REFERENCE ONLY - Part 1.pdf PDF
Building 1- Life Safety Plans- 4-11-13 FOR REFERENCE ONLY - Part 2.pdf PDF
36C77623B0016 0004.pdf PDF
James Haley Veterans Hospital - Record Drawings 2.pdf PDF
James Haley Veterans Hospital - Record Drawings 1.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 9-15-23.pdf PDF
36C77623B0016 0003.pdf PDF
36C77623B0016 0002.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 8-25-23.pdf PDF
Site Visit Sign-in Sheet - Tampa 8-15-23.pdf PDF
36C77623B0016 0001.pdf PDF
ATTACHMENT 14 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 15 - Site Visit Instructions.pdf PDF
ATTACHMENT 13 - Wage Rates - Hillsborough 1-13-23.pdf PDF
ATTACHMENT 10 - Drawings - Part 7.pdf PDF
ATTACHMENT 1 - Specifications - Volume 1.pdf PDF
ATTACHMENT 5 - Drawings - Part 2.pdf PDF
36C77623B0016 - 8-7-23.pdf PDF
ATTACHMENT 8 - Drawings - Part 5.pdf PDF
ATTACHMENT 12 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 6 - Drawings - Part 3.pdf PDF
ATTACHMENT 11 - Drawings - Part 8.pdf PDF
ATTACHMENT 7 - Drawings - Part 4.pdf PDF
ATTACHMENT 4 - Drawings - Part 1.pdf PDF
ATTACHMENT 9 - Drawings - Part 6.pdf PDF
ATTACHMENT 3 - Specifications - Volume 3 - Reference Only.pdf PDF
ATTACHMENT 2 - Specifications - Volume 2.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GROUND FLOOR HVAC DEMOLITION PLAN

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-31-23 ASI 1: TECHNICAL CLARIFICATIONS

GROUND FLOOR PLAN - HVAC DEMOLITION

NOTES:

AutoCAD SHX Text

UP

AutoCAD SHX Text

LOUVER

AutoCAD SHX Text

EL. 38.63

AutoCAD SHX Text

UP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

SCI

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

MACHINERY

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

BELOW

AutoCAD SHX Text

METAL

AutoCAD SHX Text

DOCK

AutoCAD SHX Text

HYDRAULIC

AutoCAD SHX Text

LIFT

AutoCAD SHX Text

EL. 43.22

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

AutoCAD SHX Text U

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 7.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 5.8

AutoCAD SHX Text 4.9

AutoCAD SHX Text Q

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text NOTE: AC-83 AMERICAN STANDARD MODEL 4A7C3060A3000AA AC-83 AMERICAN STANDARD MODEL 4A7C3060A3000AA AMERICAN STANDARD MODEL 4A7C3060A3000AA (5 TON UNIT USING R401 REFRIGERANT). AC-105 YORK MODEL HIRD060546B AC-105 YORK MODEL HIRD060546B YORK MODEL HIRD060546B (5 TON UNIT USING R22 REFRIGERANT).

AutoCAD SHX Text

AC-83

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-83

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

* - MINIMUM CLEARANCE REQUIRED

AutoCAD SHX Text

APPROXIMATE EXISTING LOCATION OF AHU'S

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

MINIMUM 36" BETWEEN UNITS

AutoCAD SHX Text

MINIMUM 12" ALL SIDES

AutoCAD SHX Text PAD WITH 6 x 6, # 8

AutoCAD SHX Text

6" THICK CONCRETE

AutoCAD SHX Text

REINFORCEMENT

AutoCAD SHX Text

GAUGE WIRE MESH

AutoCAD SHX Text

DISCONNECT SWITCH.

AutoCAD SHX Text

SUBCONTRACTOR.

AutoCAD SHX Text

BOLT TO WALL.

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

INSTALL BY

AutoCAD SHX Text

HEAT PUMP UNIT DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

MD101

AutoCAD SHX Text

(4) EQUALLY SPACED 14 GAUGE, TIE-DOWN STRAPS BY MIAMI TECH INC., PART #CUTD-1(OR EQUAL) WITH 1-1/2" PIN WITH WASHER TO COMPRESSOR UNIT. (TYPICAL)

AutoCAD SHX Text

3/16" DIA X 1-1/2" TAPCON ANCHOR (TYPICAL)

AutoCAD SHX Text

UNISTRUT SUPPORTS

AutoCAD SHX Text

PROVIDE EVERY 24"

AutoCAD SHX Text

REFRIGERANT PIPING. REUSE EXISTING OR PROVIDE PVC CHASE.

AutoCAD SHX Text

CONDENSING UNIT. BOLT TO CONCRETE PAD

AutoCAD SHX Text

MD101

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

ASI#1: TECHNICAL CLARIFICATIONS

AutoCAD SHX Text 08/31/23

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

RELOCATE EXISTING CONDENSING UNITS. PROVIDE NEW PIPING AS REQUIRED.

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CONDENSING UNITS TO BE RELOCATED UNDER SEPARATE CONTRACT.

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CONDENSING UNITS AND ASSOCIATED AIR HANDLING UNITS TO BE

AutoCAD SHX Text

AutoCAD SHX Text

REMOVED. RECOVER REFRIGERANT, REMOVE PAD, CONTROL WIRING TO AIR

AutoCAD SHX Text

HANDLING UNITS, REFRIGERANT PIPING AND HANGERS AND ATTACHMENTS.

AutoCAD SHX Text

COORDINATE WITH PHASING.

AutoCAD SHX Text ASI 1: Technical Clarifications

AutoCAD SHX Text 08/31/2023

AutoCAD SHX Text EXISTING CONDITIONS BASED ON SITE VISIT S IN 2017. CONTRACTOR TO VERIFY EQUIPMENT TO BE RELOCATED AND/OR REMOVED.

RESTROOM

HALL

OFFICE 1

LOCKER

DIRTYPXYIS CLEAN

EXAM 2

TEL/DATA

HALL

STAIR

WAITING

REC

RESTROOM

NURSES

EXAM 1

WOUND

TREATMENT 1

OFFICE 2OFFICE 3

RESTROOM

HALL

CONFERENCE

EXAM 4

EXAM 3

MECH/ELEC

HAC

HALL

OFFICE 5

MED

PREP

RTU CORRIDOR

EQUIP

STORAGE

MINOR

PROCEDURE 2

OFFICE 4

MINOR

PROCEDURE 1

CHANGING

WOUND

TREATMENT 2

MECH/ELEC

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-31-23 ASI 1: TECHNICAL CLARIFICATIONS

GROUND FLOOR MECHANICAL PLAN - HYDRONIC

HEAT EXCHANGER LAYOUT

SECTION VIEW "B"

AutoCAD SHX Text N.8

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text N.9

AutoCAD SHX Text S.8

AutoCAD SHX Text R.4

AutoCAD SHX Text

AutoCAD SHX Text U

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text N.8

AutoCAD SHX Text N.9

AutoCAD SHX Text S.8

AutoCAD SHX Text R.4

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text

MED GAS

AutoCAD SHX Text

UP

AutoCAD SHX Text

CAV-G-1

AutoCAD SHX Text

CAV-G-3

AutoCAD SHX Text

CAV-G-2

AutoCAD SHX Text

CAV-G-4

AutoCAD SHX Text

CAV-G-8

AutoCAD SHX Text

CAV-G-6

AutoCAD SHX Text

CAV-G-5

AutoCAD SHX Text

CAV-G-7

AutoCAD SHX Text

CAV-G-9

AutoCAD SHX Text

CAV-G-10

AutoCAD SHX Text

GB-060

AutoCAD SHX Text C0-22-1

AutoCAD SHX Text

GB-057

AutoCAD SHX Text

GB-069

AutoCAD SHX Text

GB-047

AutoCAD SHX Text

GB-048

AutoCAD SHX Text

GB-046

AutoCAD SHX Text

GB-061

AutoCAD SHX Text

GB-043

AutoCAD SHX Text C0-23-1

AutoCAD SHX Text S0-23-1

AutoCAD SHX Text

GB-040

AutoCAD SHX Text

GB-042

AutoCAD SHX Text

GB-059

AutoCAD SHX Text

GB-072

AutoCAD SHX Text

GB-058

AutoCAD SHX Text

GB-071

AutoCAD SHX Text

GB-056

AutoCAD SHX Text

GB-055

AutoCAD SHX Text

GB-067

AutoCAD SHX Text C0-25-1

AutoCAD SHX Text

GB-051

AutoCAD SHX Text

GB-063

AutoCAD SHX Text

GB-062

AutoCAD SHX Text

GB-044

AutoCAD SHX Text

GB-066

AutoCAD SHX Text C0-24-1

AutoCAD SHX Text

GB-049

AutoCAD SHX Text

GB-068

AutoCAD SHX Text

RTU-01

AutoCAD SHX Text

GB-045

AutoCAD SHX Text

GB-053

AutoCAD SHX Text

GB-050

AutoCAD SHX Text

GB-054

AutoCAD SHX Text

GB-070

AutoCAD SHX Text

GB-065

AutoCAD SHX Text

4" CHWS

AutoCAD SHX Text

4" CHWS FROM ROOF

AutoCAD SHX Text

4" CHWR FROM ROOF

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text

4" CHWR UP TO ROOF

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text

2 1/2" HWS & HWR UP TO FIRST FLOOR

AutoCAD SHX Text

2" HWS & HWR

AutoCAD SHX Text

1" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

1 1/4" HWS & HWR

AutoCAD SHX Text

1 1/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

1" HWS & HWR

AutoCAD SHX Text

1" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

1" HWS & HWR

AutoCAD SHX Text

3/4" HWS & HWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

AHU-G-1

AutoCAD SHX Text

2 1/2" CHWR

AutoCAD SHX Text

%%UAS-1-CW

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text

4" CHWS

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text P-2

AutoCAD SHX Text P-1

AutoCAD SHX Text P-4

AutoCAD SHX Text P-3

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text

3" HWR TO HX-1 & HX-2. FOR CONTINUATION SEE HEAT EXCHANGER LAYOUT

AutoCAD SHX Text

1"COND FROM HX-1 & HX-2. FOR CONTINUATION SEE HEAT EXCHANGER LAYOUT

AutoCAD SHX Text

2"MPS AND 1"PC BELOW FLOOR. FOR CONTINUATION, SEE SHEET MG101

AutoCAD SHX Text

%%UAS-1-HW

AutoCAD SHX Text

CONDENSATE PUMP

AutoCAD SHX Text

1 1/2" HWS & HWR

AutoCAD SHX Text B

AutoCAD SHX Text

MH301

AutoCAD SHX Text

2 1/2" CHWS

AutoCAD SHX Text

4" CHWR & CHWS TO BASEMENT. FOR CONTINUATION, SEE SHEET MG101

AutoCAD SHX Text

SHOT FEEDER

AutoCAD SHX Text

SHOT FEEDER

AutoCAD SHX Text

EMCS PANEL

AutoCAD SHX Text N.8

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text P

AutoCAD SHX Text

3" HWS

AutoCAD SHX Text

CONDENSATE PUMP ON FLOOR

AutoCAD SHX Text

1" CONDENSATE TO CONDENSATE RECEIVER

AutoCAD SHX Text

HX-1

AutoCAD SHX Text

HX-2

AutoCAD SHX Text

3" HWR

AutoCAD SHX Text

2" MPS

AutoCAD SHX Text

GB-044

AutoCAD SHX Text

%%UAS-1-HW

AutoCAD SHX Text P-4

AutoCAD SHX Text P-3

AutoCAD SHX Text P-2

AutoCAD SHX Text P-1

AutoCAD SHX Text

AHU-G-1

AutoCAD SHX Text

%%UAS-1-CW

AutoCAD SHX Text

%%UAS-1-HW

AutoCAD SHX Text

CONDENSATE PUMP

AutoCAD SHX Text

HX-1

AutoCAD SHX Text

1" CONDENSATE

AutoCAD SHX Text

4" CHWS

AutoCAD SHX Text

1 1/2" HWS & HWR

AutoCAD SHX Text

2 1/2" CHWS & CHWR

AutoCAD SHX Text

3" HWS & HWR

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text

4" CHWS

AutoCAD SHX Text

4" CHWR

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text N

AutoCAD SHX Text 0'

AutoCAD SHX Text

GRAPHIC SCALE 1/4" = 1'-0"

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

GROUND FLOOR MECHANICAL PLAN - HYDRONIC

AutoCAD SHX Text

MH301

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text 0'

AutoCAD SHX Text

GRAPHIC SCALE 1/4" = 1'-0"

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text 0'

AutoCAD SHX Text

GRAPHIC SCALE 1/4" = 1'-0"

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

4'

CONSTANT VOLUME AHU FLOW LAYOUT

Constant Volume AHU Sequence

SUPPLY FAN CONTROL: THE SUPPLY FAN WILL BE STARTED BASED ON OCCUPANCY SCHEDULE. WHEN THE SUPPLY FAN STATUS INDICATES THE FAN STARTED, THE CONTROL SEQUENCE WILL BE ENABLED.

THE SUPPLY FAN WILL MODULATE TO MAINTAIN THE CONSTANT AIRFLOW BASED ON DISCHARGE STATIC PRESSURE. UPON A LOSS OF AIRFLOW, THE SYSTEM WILL AUTOMATICALLY RESTART. UNIT AIRFLOW

WILL BE MONITORED VIA A FAN MOUNTED PIZO.

MINIMUM OA CONTROL: THE MINIMUM OA INJECTION FAN WILL OPERATE WHEN THE UNIT IS IN

OCCUPIED MODE, THE MINIMUM OA DAMPER WILL OPEN PRIOR TO STARTING THE FAN.

TEMPERATURE CONTROL: THE DISCHARGE AIR TEMPERATURE SETPOINT WILL BE RESET AS THE ZONE

TEMPERATURE CHANGES.

OCCUPIED MODE: THE OCCUPANCY MODE WILL BE CONTROLLED VIA A NETWORK INPUT. THE

OCCUPANCY MODE CAN ALSO BE OVERRIDDEN BY A NETWORK INPUT OR A TEMPORARY OCCUPANCY

SWITCH ON THE ZONE TEMPERATURE SENSOR

UNOCCUPIED MODE: THE UNIT WILL REMAIN OFF DURING UNOCCUPIED PERIODS.

COOLING COIL: THE COOLING COIL WILL MODULATE TO MAINTAIN THE TEMPERATURE SETPOINT.

WHEN THE UNIT IS SHUTDOWN, THE COOLING COIL WILL BE COMMANDED TO A PRESET POSITION

SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE

SETPOINT. UPON A LOSS OF AIRFLOW, THE COOLING COIL WILL BE OFF.

ADDITIONAL POINTS MONITORED BY THE FMS:

· MINIMUM OUTDOOR AIR FAN STATUS (MOAF-S)

· MINIMUM OUTDOOR AIR DAMPER STATUS (MOAD-S)

· DISCHARGE AIR VELOCITY PRESSURE (DA-VP)

· RETURN AIR TEMPERATURE (RA-T)

· RETURN AIR HUMIDITY (RA-H)

· ZONE HUMIDITY (ZN-H)

· PREFILTER DIFF PRESSURE (PFILT-DP)

· FINAL FILTER DIFFERENTIAL PRESSURE (FFILT-DP)

· LOW TEMPERATURE ALARM (LT-A)

DA-TDA-VP

DPR-O

HWS

HWR

H C

B

C A

HTG-O

ZN-T

WC-ADJ

ZN-TOCC

SA DA

CONSTANT VOLUME FLOW LAYOUT

Constant Volume Terminal Box Sequence

OCCUPIED MODE: WHEN THE ZONE TEMPERATURE IS BETWEEN THE OCCUPIED HEATING AND COOLING SETPOINTS (INSIDE OF THE BIAS). ON A DROP IN ZONE TEMPERATURE BELOW THE HEATING SETPOINT, THE REHEAT COIL WILL BE USED TO MAINTAIN THE ZONE TEMPERATURE.

DISCHARGE AIR TEMP SENSOR: A DISCHARGE AIR TEMP SENSOR IS PROVIDED ON EACH BOX FOR

MONITORING PURPOSES.

OCCUPANCY CONTROL: A TEMPORARY OCCUPANCY BUTTON ON THE ZONE SENSOR WILL PLACE THE

BOX IN OCCUPIED MODE FOR AN ADJUSTABLE LENGTH OF TIME.

UNIT ENABLE: A NETWORK UNIT ENABLE SIGNAL WILL CONTROL THE MODE OF THE BOX.

NETWORK WARMUP-COOLDOWN: WARMUP-COOLDOWN MODES WILL BE ACTIVATED BY A NETWORK

COMMAND.

ADDITIONAL POINTS MONITORED BY THE FMS:

· ZONE HUMIDITY (ZN-H)

BACnet Input from Lighting Control

System

LIGHTING CONTROL

INTEGRATION

DDC Control System shall integrate Lighting Control via

BACnet.

Lighting System Control and display will reside on the DDC front end

LIGHTING CONTROL INTEGRATION

AHU-G-1 FLOW DIAGRAM (RTU-1-1 SIMILAR)

MOAF-C

MOAF-S SDR-4

MOAF STARTER

MIN

OA

SUPPLY

RETURN

CLG-O

C C

FFILT-DP

PFILT-DP

OA

EA

DA

RA

SF-C

SF-S

SDR-1

DA-T

SF VFD

LT-A

RA-T

RA-H

DA-VP

DAPHI-A

L H

DA1-P

LH

LOCATED 2/3 DOWN THE

LONGEST DUCT RUN

N C

MOAD-C

SF-O

MOAD-S

ZN-T

ZN-H

WC-ADJ

ZN-TOCC

H N24 VAC

SDR-1LT-A

FOR WIRING OF SAFETY

SHUTDOWN RELAY (SDR-N)

CONTACTS, SEE

DESIGNATION ON STARTER/

VFD DETAIL.

Safety Shutdown Relay Coil Wiring Detail

FIRE ALARM

SHUTDOWNDAPHI-A

(If used)

SDR-4

SUZANNE LEVISEUR P.E.

LICENSE NO. 36120

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290

JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-31-23 ASI 1: TECHNICAL CLARIFICATIONS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SL

AutoCAD SHX Text

JB

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revisions to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text

MH404

AutoCAD SHX Text

AutoCAD SHX Text

ASI 1: TECHNICAL CLARIFICATIONS

08/31/2023

Electrical Legend, Schedules, Details, and Demolition Site Plan

NOTES:

ELECTRICAL LEGEND

NAMIR A. HADDAD P.E.

LICENSE NO. 31967

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290 JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-31-23 ASI #1 TECHNICAL CLARIFICATIONS

GENERAL NOTES:

NURSE CALL SYSTEM

FIRE ALARM

GROUND FLOOR DEMOLITION PLAN - ELECTRICAL

DEMOLITION NOTES:

SECURITY LEGEND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING BUILDING 19

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING BUILDING 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING SHACK

AutoCAD SHX Text

TO BE REMOVED.

AutoCAD SHX Text

EXISTING CANOPY

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-83

AutoCAD SHX Text

APPROXIMATE EXISTING LOCATION OF AHU'S

AutoCAD SHX Text

AC-105

AutoCAD SHX Text

AC-83

AutoCAD SHX Text

UP

AutoCAD SHX Text

LOUVER

AutoCAD SHX Text

EL. 38.63

AutoCAD SHX Text

UP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

WHEEL CHAIR RAMP

AutoCAD SHX Text

SCI

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

MACHINERY

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

BELOW

AutoCAD SHX Text

METAL

AutoCAD SHX Text

DOCK

AutoCAD SHX Text

RAILING

AutoCAD SHX Text

STOR.

AutoCAD SHX Text

EL. 43.22

AutoCAD SHX Text

PASS-THRU

AutoCAD SHX Text

WINDOW

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

CONCRETE

AutoCAD SHX Text

RAMP

AutoCAD SHX Text

HANDRAILS

AutoCAD SHX Text

EI100

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text EXISTING A/C UNITS TO BE RELOCATED. PROVIDE ALL CONDUITS, CABLES, AND ALL OTHER REQUIRED MATERIALS FOR A COMPLETE RELOCATION OF ELECTRICAL. EXISTING CONDENSING UNITS TO BE RELOCATED UNDER SEPARATE CONTRACT. EXISTING A/C UNITS TO BE REMOVED. REMOVE CABLES AND SURFACE MOUNTED CIRCUITS. EXISTING BUILDING ELECTRICAL SERVICE TO BE REMOVED. PULL ELECTRICAL SERVICE BACK TO SOURCE AT SWITCHGEAR. EXISTING ELEVATOR AND ASSOCIATED ELECTRICAL TO BE REMOVED. PULL ELECTRICAL SERVICE BACK TO SOURCE AT SWITCHGEAR AND REMOVE EXPOSED CONDUITS. EXISTING SHACK. REMOVE ALL ASSOCIATED ELECTRICAL. PULL ELECTRICAL SERVICE BACK TO SOURCE AND REMOVE EXPOSED CONDUITS. EXISTING CANOPY AND ASSOCIATED ELECTRICAL TO BE REMOVED. PULL ELECTRICAL BACK TO SOURCE AND REMOVE EXPOSED CONDUITS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (LIFE SAFETY BRANCH).

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

JAMES A. HALEY VETERANS' HOSPITAL

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text

SPECIALTY TREATMENT EXPANSION

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

PROJECT- BUILDING #1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NAH

AutoCAD SHX Text

WH

AutoCAD SHX Text 100%%% Submittal

AutoCAD SHX Text 04/06/18

AutoCAD SHX Text Construction Set Submittal

AutoCAD SHX Text 05/25/18

AutoCAD SHX Text Bid Submittal per VA Comments

AutoCAD SHX Text 01/27/20

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text Revision to Meet Current Requirements

AutoCAD SHX Text 01/18/21

AutoCAD SHX Text 08/19/22

AutoCAD SHX Text Physical and Electrical Security Update

AutoCAD SHX Text

1. ALL CONDUITS SHALL BE CONCEALED IN WALL, CEILING, OR UNDERGROUND. SURFACE CONDUITS WILL ALL CONDUITS SHALL BE CONCEALED IN WALL, CEILING, OR UNDERGROUND. SURFACE CONDUITS WILL BE PERMITTED IN ELECTRICAL AND MECHANICAL ROOMS ONLY. CONTRACTOR SHALL CUT EXISTING WALLS TO CONCEAL CONDUITS. REPAIR ALL WALLS TO ITS ORIGINAL CONDITION AFTER INSTALLING CONDUIT OR OUTLET BOXES. 2. DUPLEX RECEPTACLES ARE PROVIDED IN MECHANICAL ROOMS TO POWER ENERGY MANAGEMENT DUPLEX RECEPTACLES ARE PROVIDED IN MECHANICAL ROOMS TO POWER ENERGY MANAGEMENT CONTROL BOXES. COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATION OF BOXES. PROVIDE 3 #12 WIRES IN 3/4" CONDUIT FROM BOX TO ASSOCIATED DUPLEX RECEPTACLES. 3. SEE ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. SEE ARCHITECTURAL CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. 4. CONNECT MOTORIZED DAMPERS TO CLOSEST 120V RECEPTACLE CIRCUIT. COORDINATE WITH CONNECT MOTORIZED DAMPERS TO CLOSEST 120V RECEPTACLE CIRCUIT. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATION. 5. INTERLOCK EXHAUST FAN WITH RESPECTIVE AHU. PROVIDE REQUIRED #12 WIRE IN CONDUIT. SEE INTERLOCK EXHAUST FAN WITH RESPECTIVE AHU. PROVIDE REQUIRED #12 WIRE IN CONDUIT. SEE MECHANICAL DRAWINGS, FAN SCHEDULE, FOR INTERLOCK. PROVIDE TRANSFORMER AT LOCATION OF FAN TERMINAL BOX. COORDINATE WITH HVAC CONTRACTOR. 6. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ADEQUATE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ADEQUATE WORKING SPACE FOR ALL PANEL BOARDS, MOTOR STARTERS AND FUSED DISCONNECT SWITCH. WORKING SPACE SHALL BE CLEAR OF PIPES AND DUCTS. ANY CODE VIOLATION AS A RESULT OF LACK OF COORDINATION SHALL BE RECTIFIED AT NO COST TO OWNER. 7. PROVIDE NEW CEILING TILES SAME TYPE AS EXISTING TO REPLACE DAMAGED TILES AS A RESULT OF PROVIDE NEW CEILING TILES SAME TYPE AS EXISTING TO REPLACE DAMAGED TILES AS A RESULT OF CONTRACTOR OPERATION. 8. FIREPROOF ALL WALL AND FLOOR PENETRATIONS. AT COMPLETION OF PROJECT PROVIDE A LETTER FIREPROOF ALL WALL AND FLOOR PENETRATIONS. AT COMPLETION OF PROJECT PROVIDE A LETTER CERTIFYING THAT ALL WALL OPENINGS HAVE BEEN RESTORED AND VOIDS FILLED WITH FIRE RATED COMPOUND BY CONTRACTOR. 9. RESTORE DISTURBED WALLS TO ITS ORIGINAL CONDITION. FINISH AND PAINT DAMAGED AREAS, PAINT RESTORE DISTURBED WALLS TO ITS ORIGINAL CONDITION. FINISH AND PAINT DAMAGED AREAS, PAINT SHALL MATCH EXISTING. 10. PVC CONDUITS WILL BE PERMITTED IN UNDERGROUND APPLICATIONS EXCEPT FEEDERS OR BRANCH PVC CONDUITS WILL BE PERMITTED IN UNDERGROUND APPLICATIONS EXCEPT FEEDERS OR BRANCH CIRCUITS TO PATIENT CARE AREAS. 11. ALL EXTERIOR WALL MOUNTED JUNCTION BOXES SHALL BE NEMA-3R. ALL EXTERIOR WALL MOUNTED JUNCTION BOXES SHALL BE NEMA-3R. 12. PROVIDE UPDATED, TYPED PANEL BOARD SCHEDULES FOR ALL THE ELECTRICAL PANELS LOCATED IN PROVIDE UPDATED, TYPED PANEL BOARD SCHEDULES FOR ALL THE ELECTRICAL PANELS LOCATED IN THE ELECTRICAL ROOMS. PANEL SCHEDULES SHALL REFLECT THE CORRECT ROOM NAMES AND NUMBERS AND ANY CIRCUIT CHANGES MADE IN THE FIELD. 13. ROOF PENETRATIONS TO ROOF MOUNTED EQUIPMENT MUST BE WITHIN EQUIPMENT CURBS. STUB-UP ROOF PENETRATIONS TO ROOF MOUNTED EQUIPMENT MUST BE WITHIN EQUIPMENT CURBS. STUB-UP TO ABOVE ROOF THRU SIDE OF CURB FOR EXTERNAL EQUIPMENT CONNECTIONS (TYPICAL). DO NOT RUN CONDUIT IN AIR SUPPLY OR RETURN AIR OPENINGS. 14. PROVIDE CONDUITS FOR ALL H.V.A.C. SYSTEM CONTROL WIRING. PROVIDE 3/4" CONDUIT FROM EACH PROVIDE CONDUITS FOR ALL H.V.A.C. SYSTEM CONTROL WIRING. PROVIDE 3/4" CONDUIT FROM EACH A.H.U. UNIT TO ASSOCIATED THERMOSTAT. PROVIDE 3/4" CONDUIT WIRE AND CONDUITS FOR EXHAUST FANS CONTROL. SEE MECHANICAL DRAWINGS FOR LOCATION OF THERMOSTATS AND MECHANICAL EQUIPMENT. 15. ALL CONDUITS PENETRATING A SMOKE WALL SHALL BE RIGID STEEL AND HAVE 3" CLEARANCE ALL ALL CONDUITS PENETRATING A SMOKE WALL SHALL BE RIGID STEEL AND HAVE 3" CLEARANCE ALL AROUND THE CONDUIT TO ANY OBSTRUCTION TO ALLOW FOR PROPER SEALING OF PENETRATIONS. ALL NURSE CALL STATIONS MOUNTED ON SMOKE WALLS SHALL HAVE SEPARATE DRYWALL ENCLOSURES ON ALL SIDES AND BACK. CONDUITS SHALL SMOKE WALLS SHALL HAVE SEPARATE DRYWALL ENCLOSURES ON ALL SIDES AND BE SUPPORTED WITHIN 12" FROM BOTH SIDES OF SMOKE WALL (TYPICAL). 16. ALL PANEL BOARDS, DISCONNECT SWITCHES AND COMBINATION MOTOR STARTERS SHALL HAVE A ALL PANEL BOARDS, DISCONNECT SWITCHES AND COMBINATION MOTOR STARTERS SHALL HAVE A MINIMUM OF 3'-0" WORKING CLEARANCE FOR 120/208V, AND 4'-0" WORKING CLEARANCE FOR 277/480V. 17. FOR 120V CIRCUITS, PROVIDE # 12 AWG FOR ANY CIRCUIT OVER 60'-0" IN LENGTH AND #10 AWG FOR 120V CIRCUITS, PROVIDE # 12 AWG FOR ANY CIRCUIT OVER 60'-0" IN LENGTH AND #10 AWG FOR ANY CIRCUIT OVER 160'-0" ON A 20A CIRCUIT BREAKER. 18. ALL RECEPTACLES AND SWITCHING FOR DEVICES CONNECTED TO THE EMERGENCY SYSTEM SHALL BE ALL RECEPTACLES AND SWITCHING FOR DEVICES CONNECTED TO THE EMERGENCY SYSTEM SHALL BE RED IN COLOR, TYPICAL THROUGHOUT. COVER PLATES SHALL BE STAINLESS STEEL AND ENGRAVED IN RED COLOR "PANEL & CIRCUIT No." 19. ALL BRANCH CIRCUITS SERVING PATIENT CARE AREAS SHALL BE IN METAL RACEWAY. PVC CONDUIT ALL BRANCH CIRCUITS SERVING PATIENT CARE AREAS SHALL BE IN METAL RACEWAY. PVC CONDUIT OR MC CABLE WILL NOT BE ALLOWED IN PATIENTS CARE AREAS. 20. INSTALL A GREEN EQUIPMENT GROUND WIRE IN ALL CONDUITS DEVICES AND EQUIPMENT BONDING INSTALL A GREEN EQUIPMENT GROUND WIRE IN ALL CONDUITS DEVICES AND EQUIPMENT BONDING SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. GROUNDING WIRES SHALL BE SIZED IN ACCORDANCE TO N.E.C. 21. ALL FIRE ALARM AND EMERGENCY POWER JUNCTION BOXES, COVERS AND CONDUITS IN CEILING ALL FIRE ALARM AND EMERGENCY POWER JUNCTION BOXES, COVERS AND CONDUITS IN CEILING SPACE AND ELECTRICAL ROOMS SHALL BE PAINTED AS FOLLOWS: CRITICAL BRANCH - ORANGE LIFE SAFETY BRANCH - YELLOW EQUIPMENT BRANCH - GREEN FIRE ALARM - RED 22. FLEXIBLE STEEL CONDUIT MAY BE USED FOR CONNECTIONS TO RECESSED LIGHTING FIXTURES FLEXIBLE STEEL CONDUIT MAY BE USED FOR CONNECTIONS TO RECESSED LIGHTING FIXTURES (MAXIMUM LENGTH 6-FEET) AND TO MOTORS (MAXIMUM LENGTH 18 INCHES). ALL FLEXIBLE CONDUIT CONNECTIONS SHALL BE PROVIDED WITH A GREEN INSULATED GROUND WIRE. A TOTAL OF SIX FEET MAXIMUM BETWEEN THE BRANCH PANEL BOARD AND THE LAST OUTLET ON ANY CIRCUIT IS ACCEPTABLE. THE USE OF FLEXIBLE CONDUIT SHALL BE LIMITED TO JUNCTION BOX TO LIGHTING FIXTURES, JUNCTION BOX TO VIBRATING EQUIPMENT (MOTOR, FAN, ETC.) AND SHALL BE MINIMIZED AND ONLY USED WHERE ABSOLUTELY REQUIRED. 23. PROVIDE GREEN INSULATION GROUND FOR ALL GROUNDING TYPE RECEPTACLES AND EQUIPMENT OF PROVIDE GREEN INSULATION GROUND FOR ALL GROUNDING TYPE RECEPTACLES AND EQUIPMENT OF ALL VOLTAGES. IN ADDITION TO GROUNDING STRAP CONNECTION TO METALLIC OUTLET BOXES, A SUPPLEMENTAL GROUNDING WIRE AND SCREW EQUAL TO RACO NO. 983 SHALL BE PROVIDED TO CONNECT RECEPTACLE GROUND TERMINAL TO THE BOX. 24. PERFORM GROUND INTEGRITY TEST AND EQUIPOTENTIAL IN ACCORDANCE WITH NEC 517-11,13,14, PERFORM GROUND INTEGRITY TEST AND EQUIPOTENTIAL IN ACCORDANCE WITH NEC 517-11,13,14, AND 16 AND NFPA-99, CHAPTER 3.5. SUBMIT (3) THREE SIGNED COPIES OF REPORT. EQUIPOTENTIAL GROUNDING TEST DOCUMENTATION AND DEMONSTRATION OF THE EQUIPOTENTIAL TEST SHALL BE PROVIDED AT THE FINAL AHCA SURVEY. USE A HAMPDEN #MOV TESTER OR EQUAL. TECHNICIAN AND CALIBRATED TESTER SHALL BE PRESENT AT AHCA FINAL INSPECTION. 25. THE SIZE OF WIRING, CONDUIT, DISCONNECT AND FUSES FOR HVAC EQUIPMENT IS BASED ON THE THE SIZE OF WIRING, CONDUIT, DISCONNECT AND FUSES FOR HVAC EQUIPMENT IS BASED ON THE MECHANICAL BASIS OF DESIGN. COORDINATE WITH MECHANICAL CONTRACTOR VERIFY ELECTRICAL REQUIREMENTS FOR EQUIPMENT SUPPLIED. IF THE BASIS OF DESIGN IS NOT USED. THE CONTRACTOR SHALL RESIZE THESE ITEMS PER THE NATIONAL ELECTRICAL CODE AND MANUFACTURER'S RECOMMENDATIONS AND SHALL SHALL SUBMIT THIS DATA WITH THE HVAC SUBMITTAL FOR APPROVAL. 26. PROVIDE ALL THE REQUIRED WIRING AND CONDUIT TO CONNECT MOTORIZED DAMPERS AND INTERLOCK PROVIDE ALL THE REQUIRED WIRING AND CONDUIT TO CONNECT MOTORIZED DAMPERS AND INTERLOCK HVAC EQUIPMENT. SEE MECHANICAL FOR EXACT PAIRING. 27. VERIFY WITH OWNER FOR EQUIPMENT'S ELECTRICAL CHARACTERISTICS PRIOR TO ROUGH IN. VERIFY WITH OWNER FOR EQUIPMENT'S ELECTRICAL CHARACTERISTICS PRIOR TO ROUGH IN. 28. PROVIDE NURSE CALL DOCUMENTATION AND CERTIFICATIONS. NURSE CALL TECHNICIAN SHALL BE PROVIDE NURSE CALL DOCUMENTATION AND CERTIFICATIONS. NURSE CALL TECHNICIAN SHALL BE PRESENT AT FINAL INSPECTION. 29. PROVIDE DUCT SMOKE DETECTOR SENSITIVITY TEST REPORTS AND FIRE ALARM CERTIFICATION PROVIDE DUCT SMOKE DETECTOR SENSITIVITY TEST REPORTS AND FIRE ALARM CERTIFICATION DOCUMENTS. TEST REPORT SHALL BE AVAILABLE FOR INSPECTIONS REVIEW AT FINAL SURVEY. FIRE ALARM TECHNICIAN SHALL BE PRESENT AT FINAL INSPECTION. 30. CONTRACTOR SHALL INCLUDE AS PART OF BASE BID COST FOR ADDITIONAL ELECTRICAL WORK AS CONTRACTOR SHALL INCLUDE AS PART OF BASE BID COST FOR ADDITIONAL ELECTRICAL WORK AS MAY BE NEEDED ON THIS PROJECT TO INCLUDE (3) FIRE ALARM SPEAKER STROBES, (3) FIRE ALARM DUCT DETECTORS, (3) TYPE 'E' LIGHTING FIXTURES, (4) DATA OUTLETS (5 CAT6 JACKS EACH), AND (8) DUPLEX RECEPTACLES. INCLUDE UP TO 150 FEET CONDUIT AND ASSOCIATED CABLES PER OUTLET/DEVICE. IN ADDITION TO ABOVE WORK PROVIDE 600 FEET OF 3/4"CONDUIT AND 2000 FEET OF THHN #8 CABLE. ALLOWANCES FOR ADDITIONAL WORK SHALL INCLUDE REQUIRED BOXES, FITTINGS, SUPPORT, DRILLING OF WALLS/BEAMS, PAINTING, REPAIRING OF EXISTING SURFACES, FIRE STOPPING AND ALL HARDWARE AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. ALLOWANCES SHALL ALSO INCLUDE ALL REQUIRED PROGRAMMING AND TESTING. LOCATION OF DEVICES TO BE DETERMINED DURING CONSTRUCTION. UNUSED DEVICES SHALL BE DELIVERED TO THE VA HOSPITAL AS SPARE PARTS. 31. LIGHTING CONTROL COMMISSIONING: PROVIDE FUNCTIONAL TESTING FOR EACH SPACE. PROVIDE TEST LIGHTING CONTROL COMMISSIONING: PROVIDE FUNCTIONAL TESTING FOR EACH SPACE. PROVIDE TEST REPORT FOR REVIEW NO FEWER THAN 5 DAYS PRIOR TO THE FINAL INSPECTION. 32. ALL NORMAL POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWDER COATED ALL NORMAL POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWDER COATED IVORY AND ENGRAVED WITH CIRCUIT NUMBER. ALL EMERGENCY POWER RECEPTACLES AND SWITCHES SHALL BE STAINLESS STEEL POWDER COATED RED AND ENGRAVED WITH CIRCUIT NUMBER. 33. PROVIDE EZ PATH FIRE PROOFING FOR CABLE TRAYS PENETRATING FIRE RATED WALL. SIZE BLOCKS PROVIDE EZ PATH FIRE PROOFING FOR CABLE TRAYS PENETRATING FIRE RATED WALL. SIZE BLOCKS FOR QUANTITY OF CAT6 CABLES PLUS 20% CAPACITY. 34. PROVIDE 120V, POWER TO ALL ELECTRICALLY OPERATED FLUSH VALVES OR WATER VALVE. PROVIDE 120V, POWER TO ALL ELECTRICALLY OPERATED FLUSH VALVES OR WATER VALVE. COORDINATE WITH PLUMBING CONTRACTOR.

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text LED LIGHTING FIXTURE - RECESSED WITH JUNCTION BOX AND FLEXIBLE METALLIC CONDUIT CONNECTION.

AutoCAD SHX Text

FIXTURE WITH BATTERY BACK-UP, CONNECTED TO CRITICAL BRANCH.

AutoCAD SHX Text

LED LIGHTING FIXTURE - SURFACE MOUNTED.

AutoCAD SHX Text LEDLIGHTING FIXTURE - SURFACE MOUNTED. CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text

LED LIGHTING FIXTURE - SURFACE MOUNTED. CONNECTED ON EMERGENCY POWER

AutoCAD SHX Text

(LIFE SAFETY BRANCH).

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED.

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED. CONNECTED ON EMERGENCY POWER (CRITICAL BRANCH).

AutoCAD SHX Text

LED DOWNLIGHT - RECESSED. CONNECTED ON EMERGENCY POWER (LIFE SAFETY BRANCH).

AutoCAD SHX Text EXIT LIGHT - PROVIDE ARROWS AS INDICATED, SHADING DENOTES FACE OPERATION. DO NOT SWITCH.

AutoCAD SHX Text

STAINLESS STEEL COVERPLATE - 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL1221I WITH

AutoCAD SHX Text

LOW VOLTAGE DIMMER SWITCH, IVORY, 46" MOUNTING HEIGHT, U.N.O. WATTSTOPPER MODEL

AutoCAD SHX Text

AS INDICATED ON PLANS WITH STEEL COVER PLATE.

AutoCAD SHX Text

LOW VOLTAGE DIMMER SWITCH, RED, 46" MOUNTING HEIGHT, U.N.O. WATTSTOPPER MODEL

AutoCAD SHX Text

AS INDICATED ON PLANS WITH IVORY STAINLESS STEEL COVER PLATE - CRITICAL POWER.

AutoCAD SHX Text

CEILING MOUNTED LOW VOLTAGE OCCUPANCY SENSOR-WATTSTOPPER #LMDC-100-U.

AutoCAD SHX Text

WATTSTOPPER ELCU-200 EMERGENCY BYPASS. SEE LIGHTING CONTROL DIAGRAMS.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT, HUBBELL NO. HBL1221R

AutoCAD SHX Text

WITH STAINLESS STEEL COVERPLATE - CRITICAL POWER - 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

EMERGENCY POWER OFF PUSH BUTTON (EPO).

AutoCAD SHX Text S

AutoCAD SHX Text

CEILING MOUNTED PAGING SPEAKER WITH BACK BOX. PROVIDE WIRES IN CONDUIT.

AutoCAD SHX Text

BEDSIDE NURSE CALL STATION WITH PULL CORD, 42 INCH MOUNTING HEIGHT.

AutoCAD SHX Text N

AutoCAD SHX Text

NURSE CALL DUTY STATION. MOUNTED 54 INCHES ABOVE FLOOR.

AutoCAD SHX Text

BEDSIDE STATION. AUDIO/VIDEO

AutoCAD SHX Text N/C

AutoCAD SHX Text

NURSE CALL MASTER STATION.

AutoCAD SHX Text

NM

AutoCAD SHX Text

CODE BLUE STATION. COORDINATE WITH OWNER FOR MOUNTING HEIGHT.

AutoCAD SHX Text B

AutoCAD SHX Text

EMERGENCY/LAVATORY NURSE CALL STATION WITH PULL CORD

AutoCAD SHX Text E

AutoCAD SHX Text

REACHING TO FLOOR. 42 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

NURSE CALL DOME LIGHT.

AutoCAD SHX Text D

AutoCAD SHX Text

NURSE CALL ZONE LIGHT.

AutoCAD SHX Text Z

AutoCAD SHX Text

EMERGENCY CALL STAFF STATION. 42" MOUNTING HEIGHT.

AutoCAD SHX Text E

AutoCAD SHX Text

NURSE CALL STAFF STATION. 54" MOUNTING HEIGHT.

AutoCAD SHX Text S

AutoCAD SHX Text

WALL MOUNTED PAGING SPEAKER - 9'-0" MOUNTING HEIGHT.

AutoCAD SHX Text

DC

AutoCAD SHX Text

TV

AutoCAD SHX Text

DOOR CONTROL IN CEILING SPACE.

AutoCAD SHX Text CABLE RUNNER MOUNTED AT 24" ABOVE ITR RACKS. PROVIDE CABLE FALL ADAPTER EXTENDED TO ITR.

AutoCAD SHX Text

TOUCHLESS DOOR ENTRY SENSOR.

AutoCAD SHX Text D

AutoCAD SHX Text

CABLE TRAY IN CEILING SPACE.

AutoCAD SHX Text CABLE TV OUTLET - (1) COAXIAL CABLE CONNECTOR, (1) RJ-45 CONNECTOR AND IVORY COVERPLATE.

AutoCAD SHX Text

PROVIDE 3/4" C. TO CEILING SPACE.

AutoCAD SHX Text

MOTOR STARTER WITH DISCONNECT.

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text

LR

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text

LR

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

FLUSH MOUNTED MANUAL FIRE ALARM PULL STATION, 46 INCH MOUNTING HEIGHT.

AutoCAD SHX Text SEMI-FLUSH MOUNTED FIRE ALARM SPEAKER/VISUAL WARNING DEVICE, 86-96 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

DENOTES FIRE ALARM CONTROL PANEL.

AutoCAD SHX Text 110 INDICATES 110 CANDELA STROBE. UTILIZE 75 CANDELA IN SMALL ROOMS AND CORRIDORS.

AutoCAD SHX Text

USE 110 CANDELA IN ROOMS LARGER THAN 30' IN WIDTH OR LENGTH.

AutoCAD SHX Text F.A.C.P.

AutoCAD SHX Text

DENOTES FIRE ALARM ANNUNCIATOR PANEL.

AutoCAD SHX Text F.A.A.P.

AutoCAD SHX Text

(FROM FLOOR TO BOTTOM OF DEVICE)

AutoCAD SHX Text

CEILING MOUNTED SMOKE DETECTOR.

AutoCAD SHX Text

AIR CONDITIONING/HEAT PUMP SHUT DOWN RELAY.

AutoCAD SHX Text

FIRE ALARM SPRINKLER FLOW SWITCH.

AutoCAD SHX Text

FIRE ALARM SPRINKLER VALVE TAMPER SWITCH.

AutoCAD SHX Text SEMI-FLUSH FIRE ALARM VISUAL WARNING DEVICE, WALL MOUNTED. 80-96 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

TS

AutoCAD SHX Text

FS

AutoCAD SHX Text

RL

AutoCAD SHX Text R

AutoCAD SHX Text D

AutoCAD SHX Text

FLUSH WALL MOUNTED DOOR HOLDING DEVICE - 70 INCH MOUNTING HEIGHT.

AutoCAD SHX Text

DH

AutoCAD SHX Text

DRAWING FOR MOUNTING LOCATION AND QUANTITY.

AutoCAD SHX Text

DUCT MOUNTED SMOKE DETECTOR, MOUNTED IN A/C DUCT. SEE MECHANICAL

AutoCAD SHX Text

CEILING. LABEL COVERPLATE TO INDICATE RESPECTIVE A/C UNIT.

AutoCAD SHX Text DUCT MOUNTED SMOKE DETECTOR REMOTE INDICATOR WITH RESET/TEST CAPABILITY, FLUSH MOUNTED IN

AutoCAD SHX Text N

AutoCAD SHX Text

1. THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR THERE SHALL NOT BE ANY INTERRUPTION TO SERVICES TO THE EXISTING BUILDINGS WITHOUT PRIOR SCHEDULING OF SUCH OUTAGES WITH THE OWNER'S REPRESENTATIVE. 2. THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN THE CONTRACTOR SHALL NOT TAKE POSSESSION OF OR DISPOSE OF ANY SALVAGEABLE ITEMS IN ASSOCIATION WITH THE WORK. ALL SALVAGEABLE ITEMS SHALL BE THE OWNER'S PROPERTY AT HIS OPTION. ALL UNSALVAGEABLE EQUIPMENT AND MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 3. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING THE ELECTRICAL CONTRACTOR SHALL MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS TO EXISTING SYSTEMS AND SHALL UPON COMPLETION, DELIVER "AS-BUILT" DRAWINGS TO THE OWNER, INDICATING ANY SUCH CHANGES. 4. WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS WHERE FEEDERS ARE ABANDONED, WIRE SHALL BE PULLED OUT AND ALL EXPOSED SECTIONS OF CONDUITS REMOVED. ALL SWITCHES, PANELS, ETC. SHALL BE REMOVED. ALL CONCEALED CONDUITS SHALL BE CAPPED AT POINT OF CONCEALMENT. 5. ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE ALL EXISTING DEVICES AND FIXTURES IN THE PATH OF RENOVATION OR BUILDING ADDITIONS SHALL BE REMOVED BY THE CONTRACTOR. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN EXISTING CIRCUITRY TO ALL REMAINING DEVICES AND FIXTURES. FOR EACH DEVICE OR FIXTURE REMOVED AT THE END OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM LAST REMAINING DEVICE, FOR EACH DEVICE OR FIXTURE REMOVED IN THE MIDDLE OF A CIRCUIT, CONTRACTOR SHALL REMOVE WIRING FROM FIRST DEVICE OR FIXTURE BEFORE AND AFTER REMOVED DEVICE AND FIXTURE. NEW WIRING, SIZED THE SAME AS EXISTING, SHALL BE PULLED BETWEEN THE TWO REMAINING DEVICES OR FIXTURES. 6. CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS CONTRACTOR MAY REUSE EXISTING CONDUIT SYSTEM WHERE APPLICABLE, PROVIDING THE REUSED SYSTEMS MEET CURRENT CODES. REMOVE ALL UNUSED SURFACE MOUNTED CONDUIT. UNUSED CONDUITS STUBBING UP FROM FLOOR SHALL BE CUT FLUSH WITH FLOOR. 7. EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE EXISTING EQUIPMENT NOT SHOWN ON THESE PLANS AND NOT REMOVED BY OTHER TRADES SHALL BE RECONNECTED TO PANELS. EXISTING ELECTRICAL OR MECHANICAL EQUIPMENT TO REMAIN THAT HAS TO BE DISCONNECTED FOR CONSTRUCTION SHALL BE REINSTALLED. 8. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. ELECTRICAL DRAWINGS DO NOT INDICATE ALL THE EXISTING INSTALLATIONS. 9. ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT ALL EXISTING SWITCHES, RECEPTACLES, LIGHTING FIXTURES, TELEPHONE OUTLETS, ETC. THAT DO NOT INTERFERE WITH RENOVATIONS SHALL REMAIN. 10. DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH REMOVED BUILDING. MAINTAIN DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH REMOVED BUILDING. MAINTAIN EXISTING EQUIPMENT TO REMAIN. SEE DRAWING AD101 AND AD102. 11. CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING CONTRACTOR SHALL VISIT THE SITE PRIOR TO PREPARING HIS BID AND DETERMINE THE EXTENT OF EXISTING EQUIPMENT AND WIRING TO ACCOMMODATE CHANGES AND ADDITIONS. ALL THE NECESSARY REROUTING, RELOCATING AND/OR REMOVAL OF EXISTING EQUIPMENT, WIRING ETC. SHALL BE INCLUDED IN THE SCOPE OF THIS WORK. ANY VARIATION FROM EXISTING CONDITIONS SHALL BE INCLUDED UNDER THIS CONTRACT.

AutoCAD SHX Text

GRAPHIC SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 0'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 6'

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text

WALL MOUNTED CAMERA ROUGH IN

AutoCAD SHX Text

ROUGH IN FOR KEYBOARD DURESS ALARM.

AutoCAD SHX Text

ROUGH IN FOR CARD READER

AutoCAD SHX Text

DB

AutoCAD SHX Text

LMRC-102 DIGITAL DUAL RELAY ROOM CONTROLLER.

AutoCAD SHX Text

LMRC-211 RELAY ON/OFF/0-10V DIMMING ROOM CONTROLLER.

AutoCAD SHX Text TOGGLE SWITCH - SINGLE POLE, 20 AMP, 120/277V, MOTOR RATED, GROUNDING TYPE, MOUNT AT

AutoCAD SHX Text

EQUIPMENT HOUSING.

AutoCAD SHX Text VACANCY SENSOR - SWITCH, 120/277 VOLT, ADJUSTABLE DELAY OFF. WATTSTOPPER #DW-100-IVORY, AutoCAD SHX Text

IVORY STAINLESS STEEL COVERPLATE, 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DUPLEX RECEPTACLE HOSPITAL GRADE- NORMAL POWER - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL

AutoCAD SHX Text

NO. HBL8300I WITH IVORY NO. SS8 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 42" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

HUBBELL NO. HBL8300I WITH IVORY NO. SS82 COVERPLATE, 18" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text DOUBLE DUPLEX RECEPTACLES HOSPITAL GRADE - (2) TWO 20 AMP, 120 VOLT, 3 WIRE GROUNDING, AutoCAD SHX Text SPECIAL PURPOSE RECEPTACLE COMPLETE WITH COVERPLATE. RECEPTACLE TO MATCH EQUIPMENT PLUG.

AutoCAD SHX Text DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER HOSPITAL GRADE, 20 AMP, 120 VOLT, 3 WIRE

AutoCAD SHX Text GROUNDING. HUBBELL NO. GFR8300ITR WITH IVORY STAINLESS STEEL COVERPLATE, 46" MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

"EMERGENCY POWER & CIRCUIT NO." IN RED LETTERS, 18 INCH MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

3 WIRE GROUNDING. HUBBELL NO. GF8300ITR WITH RED STAINLESS STEEL ENGRAVED

AutoCAD SHX Text

HOSPITAL GRADE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A., 120 VOLT,

AutoCAD SHX Text

"EMERGENCY POWER & CIRCUIT NO." IN RED LETTERS, 18 INCH MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

3 WIRE GROUNDING. HUBBELL NO. GF8300ITR WITH RED STAINLESS STEEL PLATE ENGRAVED

AutoCAD SHX Text HOSPITAL GRADE DOUBLE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A., 120 VOLT, AutoCAD SHX Text DUPLEX RECEPTACLE HOSPITAL GRADE - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL HBL8300R WITH RED

AutoCAD SHX Text NO. SS8 COVERPLATE, ENGRAVED "EMERGENCY POWER & CIRCUIT NUMBER" ON CRITICAL BRANCH POWER, 18"

AutoCAD SHX Text

MOUNTING HEIGHT, U.N.O.

AutoCAD SHX Text

RC

AutoCAD SHX Text

DM

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text TELEPHONE/DATA OUTLET - 4" SQUARE 2 1/8" DEEP JUNCTION BOX WITH 1-GANG EXTENSION RING

AutoCAD SHX Text AND CAT 6 RJ-45 CONNECTORS. NUMBER INDICATE QUANTITY OF RJ-45 JACKS. 18" MOUNTING HEIGHT, AutoCAD SHX Text U.N.O. PROVIDE (QUANTITY EQUAL TO NUMBER OF JACKS) CAT 6 CABLES TO MTR. PROVIDE 1-1/4"

AutoCAD SHX Text

CONDUIT FROM BOX TO CEILING SPACE.

AutoCAD SHX Text

AutoCAD SHX Text

JUNCTION BOX SIZE PER NEC.

AutoCAD SHX Text J

AutoCAD SHX Text

MOTOR, FAN, PUMP OR AIR CONDITIONING UNIT CONNECTION PER NEC.

AutoCAD SHX Text

LIGHTING AND/OR POWER PANELBOARD.

AutoCAD SHX Text 3 NO. 12, U.N.O. DO NOT COMBINE HOMERUNS EXCEPT AS SPECIFICALLY INDICATED ON THE PLAN.

AutoCAD SHX Text INDICATE QUANTITY OF NO. 12 CONDUCTORS. RUNS VOID OF CROSSMARKS ARE 1/2 INCH CONDUIT, AutoCAD SHX Text HOMERUN TO PANELBOARD - NUMBER OF ARROWS DENOTES QUANTITY OF CIRCUITS. CROSSMARKS

AutoCAD SHX Text

WIRING IN CONDUIT, RUN CONCEALED UNDER FLOOR OR UNDERGROUND.

AutoCAD SHX Text

WIRING IN CONDUIT, RUN CONCEALED ABOVE CEILING OR IN WALLS.

AutoCAD SHX Text

WIRING IN CONDUIT, RUN CONCEALED ABOVE CEILING OR IN WALLS - EMERGENCY POWER.

AutoCAD SHX Text A.F.F.

AutoCAD SHX Text

WP

AutoCAD SHX Text

AutoCAD SHX Text U.N.O.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UNLESS NOTED OTHERWISE.

AutoCAD SHX Text

COVERPLATE, HUBBELL #ML-500G

AutoCAD SHX Text

DENOTES WEATHERPROOF - MOUNT RECEPTACLES HORIZONTALLY AND PROVIDE

AutoCAD SHX Text

ABOVE FINISHED FLOOR.

AutoCAD SHX Text

NIGHT LIGHT. DO NOT SWITCH.

AutoCAD SHX Text

NL

AutoCAD SHX Text

ABOVE COUNTER (8" ABOVE COUNTER)

AutoCAD SHX Text

AC

AutoCAD SHX Text

DISCONNECT SWITCH, "3 60/40" DENOTES 3 POLE, 60 AMP, 40 AMP FUSES.

AutoCAD SHX Text ASI 1: Technical Clarifications

08/31/23

UP

P Y

X

IS

P Y

X

IS

0.0000001SCSSTC46216179

0.0000001SCSSTC46216179

0.0000001SCSSTC46216179

0.000000

1SCSSTC

46216179 0.000000

1SCSSTC

46216179

0.0000001SCSSTC46216179

0.0000001SCSSTC46216179

0.0000001SCSSTC46216179

0.0000001SCSSTC46216179

0.000000 1SCS STC 46216179

TV

TV

EXAM 2

LOCKER

WOUND

TREATMENT 2

C H

A N

G

IN

G

MINOR

PROCEDURE 1

MINOR

PROCEDURE 2

MED

PREP

HAC

OFFICE 5

OFFICE 4

RTU CORRIDOR

STAIR

HALL

HALL

MECH/ELEC

EXAM 3

CONFERENCE

CLEAN

DIRTY

PXYIS

HALL

RESTROOM

OFFICE 3

RESTROOMOFFICE 2 OFFICE 1

WOUND

TREATMENT 1

EXAM 1

NURSES

HALL

RESTROOM

REC

WAITING

TEL/DATA

EQUIP

STORAGE

EXAM 4

GROUND FLOOR ELECTRICAL PLAN - POWER

NOTES:

NAMIR A. HADDAD P.E.

LICENSE NO. 31967

ttv architects, inc.

115 EAST FORSYTH ST

JACKSONVILLE, FLORIDA 32202

T 904.798.8333 F 904.798.8335 www.ttvarch.com

FL Lic#AA0002609

HADDAD ENGINEERING INC.

3030 HARTLEY ROAD SUITE #290 JACKSONVILLE, FL 32257

T 904.262.5066 F 904.262.7139 www.haddadeng.com

CERTIFICATE OF AUTHORIZATION NO. 4000

08-31-23 ASI #1 TECHNICAL CLARIFICATIONS

ABCC.2DEG FH

J H G F

T M

D B

D

C O O

LI

N G

T O W E R

A H U

V S W

IT

C H G E A R

M C C

T

A C

DN

E

LE

V A T O R

U

PD

N

MIRROR

D N

T E L E C

L O

S E T

A C

-1

A C

-1

A C

-2

A C

-1

E M

E R

G E N

C Y

G E N

E R

A T O

R

E M

E R

G E N

C Y

G E N

E R

A T O

R

E M

E R

G E N

C Y

G E N

E R

A T O

R

S T A

R T O

F B

L D

G

M O

D U

L A

R B

L D

G T

KEY PLAN

NOT TO SCALE

AutoCAD SHX Text 52"

AutoCAD SHX Text 52"

AutoCAD SHX Text 52"

AutoCAD SHX Text

GB-XEQ-P1-7

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

GB-XEQ-P1-19

AutoCAD SHX Text

GB-XEQ-P1-5

AutoCAD SHX Text

GB-N-P1-17

AutoCAD SHX Text

GB-N-P1-6

AutoCAD SHX Text

GB-N-P1-2

AutoCAD SHX Text

GB-N-P1-14

AutoCAD SHX Text

GB-N-P1-20

AutoCAD SHX Text

GB-N-P1-18

AutoCAD SHX Text

GBNP1-3

AutoCAD SHX Text

GB-N-P1-7

AutoCAD SHX Text

GB-N-P1-9

AutoCAD SHX Text

GB-N-P1-5

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

GB-XEQ-P1-3

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

GB-XEQ-P1-11

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

GB-XEQ-P1-15

AutoCAD SHX Text D

AutoCAD SHX Text

TOUCHLESS SENSOR

AutoCAD SHX Text

DOOR OPERATOR.

AutoCAD SHX Text J

AutoCAD SHX Text D

AutoCAD SHX Text

(TYPICAL.)

Auto…

This is the start of the file's text. The full file is on GovTribe.