This is a technical exhibit spreadsheet detailing sectional manual overhead doors across multiple Fort Hood facilities. The document inventories nine buildings at various locations throughout the installation, listing a total of 23 overhead sectional manual doors with curved slats. Door specifications include dimensions ranging from 8'x8' to 18'x14', with most doors classified as non-insulated (16 doors) and a smaller subset as insulated (7 doors). The buildings are identified by building numbers (ranging from 11019 to 90135) and their corresponding addresses, with specific door numbers assigned to each location for identification purposes. Notably, no manufacturer information is provided for any of the doors, and the document explicitly states it is a living document that will not be updated through contract modification as facilities are added or removed from the installation.

This technical exhibit serves as an attachment to solicitation W912DY26RA076, which is a non-personal services contract issued by the Department of the Army Corps of Engineers Engineering Support Center Huntsville for comprehensive facility maintenance services at Fort Hood, Texas. The broader solicitation encompasses preventative and corrective maintenance for approximately 136 automatic doors, 3,375 overhead doors, and commercial doors across the installation's Main Cantonment, West Fort Hood, and all areas under Fort Hood's control. The sectional manual doors listed in this exhibit represent a subset of the overhead door inventory requiring maintenance services under the contract.

View the file

Other files

File Type Posted
Solicitation Amendment W912DY26RA0760002 SF 30.pdf PDF
Fort Hood Site Visit Map.png PNG image
Marvin Leath Visitors Welcome Center-Fort Hood Information.docx DOCX document
Attachment 10 Hangar Gear Driven Doors.xlsx XLSX spreadsheet
FY26 Ft Hood Doors MnS Pricing Workbook_20260708.xlsx XLSX spreadsheet
PWS - FY26 B1 Ft Cavazos Doors MNS TE-2 Equipment List_20260423.xlsx XLSX spreadsheet
PWS - FY26 B1 Ft Hood Doors MnS TE-5 Engineer Form 3394 08012021.pdf PDF
Attachment 3 Rolling Steel Chain Gear Driven Doors.xlsx XLSX spreadsheet
Attachment 16 - Automatic Door Preventive Maintenance Checklist.xlsx XLSX spreadsheet
PWS - FY26 B1 Fort Hood Doors Appendix A Technical Exhibits.pdf PDF
PWS - FY26 B1 Ft Hood Doors MnS 20260707 - ALL.pdf PDF
Attachment 9 Hangar Chain Gear Driven Doors.xlsx XLSX spreadsheet
PWS - FY26 B1 Ft Hood Doors MnS Appendix B.2 APP Worksheet Eng_Form_6293_Aug 2024 - FINAL.pdf PDF
Attachment 19 - Overhead Door Preventive Maintenance checklist.xls XLS spreadsheet
Attachment 8 Sectional Gear Driven Doors.xlsx XLSX spreadsheet
Attachment 11 Hangar Sectional Gear Driven Doors.xlsx XLSX spreadsheet
WAGE DETERMINATIONS_FT HOOD_DBA.pdf PDF
PWS-FY26 B1 Fort Hood Doors MnS w App C to H 20260423.pdf PDF
Attachments to PWS FY26 Ft Hood Doors.pdf PDF
Attachment 1 Rolling Steel Chain Driven Doors.xlsx XLSX spreadsheet
Attachment 2 Rolling Steel Manual Doors.xlsx XLSX spreadsheet
Attachment 12 Canvas Facility Doors.xlsx XLSX spreadsheet
PWS - FY26 B1 Ft Hood Doors MnS Appendix B.1 SSHO_Designation_Eng_Form_6282_2023Aug28.pdf PDF
Attachment 5 Hangar Manual Doors.xlsx XLSX spreadsheet
SOLICITATION_W912DY-26-R-A076_ 21 July 2026.pdf PDF
Attachment 4 Sectional Chain Driven Doors.xlsx XLSX spreadsheet
PWS - FY26 B1 Fort Hood Doors TE-1 Installation Map 20240612.pdf PDF
Attachment 6 Sectional Chain Gear Driven Doors.xlsx XLSX spreadsheet
WAGE DETERMINATIONS_FT HOOD.pdf PDF
Attachment 13 Comprehensive Overhead Door List.xlsx XLSX spreadsheet
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

ATTACHEMENT 7
SECTIONAL MANUAL DOORS
This Tehnical Exhibit is a living document and will not be updated by contract modification as new facilities come on-line or are demolished.
Building NumberTechnical ExhibitAddressNumber of DoorsDoor NumbersSize of DoorsInsulated or Non InsulatedSlat TypeManufacturer
110197HOW & 27th31045-104712'x8'Non InsulatedCurved SlatsN/A
110387North Ave & 31st1109418'x14'Non InsulatedCurved SlatsN/A
130317HOW & 33rd4906, 907, 1798 310111'x8'Non InsulatedCurved SlatsN/A
150217HOW & 37th20832-083311'x8'Non InsulatedCurved SlatsN/A
380357HOW & 76TH12738'x8'InsulatedCurved SlatsN/A
440117North Ave & Clear Creek51908-19128x8InsulatedCurved SlatsN/A
500097Clear Creek & Santa Fe32110-211212'x10'Non InsulatedCurved SlatsN/A
562097West Range Rd (Hargrove MOUT Facility)22773-277412'x14Non InsulatedCurved SlatsN/A
901357Clarke Rd & Mowhawk Rd (WFH)22342-234316'x14Non InsulatedCurved SlatsN/A
23