Attachment 7 MIL-STD-3004TABLE XXVI.pdf

Military Standard PDF 387 KB Posted

Attached to
Solicitation Notice for JP8/JPTS Fuel Transportation Services
Solicitation number
SPE60220R0718
Issued by

About this file

This document contains a conversion chart for truck tanks, tank wagons, tank and trailer cars, and intermodal containers. The chart provides cleaning and conversion instructions for various cargo types being transported in the conveyances. It specifies requirements such as making sure equipment is dry, free of rust and dirt before loading. It also provides guidance on cleaning procedures when switching between compatible and incompatible cargo types to prevent contamination, including requirements to carry intermediate cargo loads to flush out residue. The document includes notes clarifying agency-specific guidance and listing additional policies on steam cleaning and dye removal.

View the file

Other versions and copies of MIL-STD-3004

Who attaches MIL-STD-3004

Other files

File Type Posted
Amend 0005 SPE60220R0718 SF30.pdf PDF
Amend 0005 SPE60220R0718 Conformed Solicitation.pdf PDF
Amend 0004 SPE60220R0718 Conformed Solicitation.pdf PDF
Amend 0004 SPE60220R0718 SF30.pdf PDF
Amend 0003 SPE60220R0718 SF30.pdf PDF
Amend 0003 SPE60220R0718 Conformed Solicitation.pdf PDF
Amend 0002 SPE60220R0718 SF30.pdf PDF
Amend 0001 Attachment 9 Q and A Responses.pdf PDF
Amend 0001 SPE60220R0718 SF30.pdf PDF
Amendment 0001 Conformed SPE60220R0718 Solicitation.pdf PDF
Attachment 3 SPE602-20-R-0718_OSP_FINAL.pdf PDF
Attachment 2 SPE602-20-R-0718- QASP_FINAL.pdf PDF
Attachment 5 Past Performance Questionnaire.pdf PDF
Attachment 4 Past Performance Experience Form.pdf PDF
Attachment 6 DLA Form 2019 Small Business Subcontracting Plan.pdf PDF
Exhibit 3 - ENERGY QAP E21.01 (JUN 2015).pdf PDF
Exhibit 4 - ENERGY QAP E22 (Apr 2016).pdf PDF
Exhibit 1 - ENERGY QAP E1 (SEP 2013).pdf PDF
Attachment 1 Pricing Schedule.xlsx XLSX spreadsheet
Exhibit 6 - ENERGY QAP E40.01 (JUL 2014).pdf PDF
Attachment 8 Shipping_Conveyance_Suitability_Load_Cleaning_Rqts_Dec_19.pdf PDF
Exhibit 5 - ENERGY QAP E35 (DEC 2011).pdf PDF
20201026_SPE60220R0718 Solicitation_FINAL.pdf PDF
Exhibit 2 - ENERGY QAP E12 POINT OF ACCEPTANCE (JUL 2015).pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Downloaded from http://www.everyspec.com

A ttachm ent 7

M

IL-STD

-3004D

T

B L

E X

X V

I C onversion C hart for T ruck T ank (T

T ) C ars, T ruck T ank w agons (T

W ), T ank & T railer (T R

R ), and Interm odal C ontainers (IM

C )) 1, 2

N O

T E

S:

1. G eneral Instructions for Tank C ars and Trucks :

a. C onveyances (all) shall be dry and free from loose rust, scale, and dirt

b. Saran lined equipm ent should not be steam cleaned; w ater w ash should suffice.

c. Petroleum productsshall not be loaded into the conveyances w hose previous cargo w as caustic, acid, or chlorinated solvents.

d. Trucks in liquid fertilizer service shall not load aviation turbine fuels directly, but shall carry out at least tw o loads of com m ercial gasoline prior to the aviation turbine fuel load.

e. C onversion of G overnm ent-ow ned tank cars from liquid fertilizer service to aviation turbine fuel service shall only be done w hen no other alternative exists. Tank cars being converted from liquid fertilizer service to a petroleum product shall be adequately cleaned to rem ove all traces of liquid fertilizer. A t a m inim um the equipm ent m ust be steam cleaned; dried and w ill be free from loose rust, scale, and dirt. A fter cleaning, equipm ent w ith unlined com partm ents should have its com partm ents lined w ith an approved coating at this tim

e. C onveyances carrying their initial load of aviation turbine fuel follow ing conversion shall not be released from the loading until they have been sam pled a m inim um of 24 hours after loading point. The sam ple shall undergo Type B -2 tests plus Therm al Stability Test (if required by the product specification). A fter Type B

-2 tests indicate com pliance w ith specification requirem ents, the conveyance can be rele ased pending results of the Therm al Stability tests. The conveyance shall not be unloaded until the loading point notifies the destination that the Therm al Stability test (w hen required) has passed. W hen the above condition applies, the D

D

250 or equivalent form shall be so noted.

2. Each M ilitary Service shall provide specific guidance for conversion of refueling equipm ent w hich exclusively handles Service petroleum products, e.g.:

ir Force guidance is contained in

T.O . 42B

- 1-1, Table 3-1.

3. To be loaded only in alum inum or stainless steel conveyance, or other conveyance lined w ith an approved epoxy coating. If equipm ent is coated, clean w ith hot fresh w ater not exceeding 58

°C (136 °F) and dry thoroughly.

4. For previous cargoes not listed, contact D

LA

Energy FEQ A for acceptability/cleaning procedures.

5. For an additional policy on steam cleaning for JP-8 see 5.3.1.2.

6. If previous cargo contained dye m arker, all traces of color m ust be rem oved.

7. If product to be loaded does not contain dye, then the vehicle shall not contain any traces of dye prior to loading.

8. A pplicable only w hen loading com patible oils; otherw ise, steam and dry.

9. Prior to Loading the A viation Fuels listed, the conveyance m ust carry a non-fam e cargo and then be steam cleaned and dried.

10. D rain and Em pty if loading B iodiesel B lends