This is a Hazardous Materials Report prepared by Water, Civil, and Environmental Inc. for the U.S. Forest Service (Boise National Forest) regarding the Gloria Ford Property in Boise County, Idaho under Contract Number 1240LR21P0058.

The report documents a comprehensive hazardous materials survey conducted on July 19, 2021, and August 18, 2021. The property, located in Township 8N, Range 5E, consists of a main house, two sheds (Shed 3 and Shed 4), and associated structures. WCE Inc. personnel inspected the property for universal wastes, hazardous materials/wastes, and toxic substances, identifying numerous items requiring removal and disposal before demolition. Key findings include an above-ground 300-gallon heating oil tank (partially full), multiple containers of flammable paints and finishes (alkyd enamel, flat enamel, waterproof cement, wood finish, and patio furniture stain), a 1-pint container of corrosive drain cleaner, propane-related materials, multiple unlabeled containers of unknown liquids, environmentally hazardous cleaners (409 spray cleaner, Pine-Sol, deep gloss floor finish), pesticides (snail, slug, and insect killer bait), K-57 septic tank cleaner, Chevron Duraplex grease with aquatic toxicity concerns, and three 55-gallon steel drums in Shed 3 (partially buried by previous 1996 landslide flow). The report identifies significant limiting factors due to landslide debris that partially buried structures and likely concealed additional hazardous materials. WCE Inc. recommends proper removal and disposal of all identified hazardous materials before demolition, with particular attention to unearthing the buried drums and characterizing unlabeled containers.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Hazardous Materials Report 1 Water, Civil, and Environmental Inc.

Gloria Ford Property August 23, 2021

514 NORTH 16TH STREET

BOISE, IDAHO 83702

(208) 319-9744

EMAIL: LELDRIDGE@WCE-INC.COM

August 23, 2021

R. Brett Barry, P.E.

Supervisory Civil Engineer Forest Service Boise National Forest 1249 S. Vinnell Way, Suite 200 Boise, ID 83709

Re: Gloria Ford Property Hazardous Materials Report, Contract Number 1240LR21P0058

Dear Mr. Barry:

Water, Civil, and Environmental Inc. (WCE Inc.) has conducted a hazardous materials survey to identify potentially hazardous materials associated with the Gloria Ford Property, located in Township 8N, Range 5E Section 2, Lots 9, 12, and 13 and Section 11, Lots 3 and 6 (herein referred to as the “Property”). The Property is accessible from State Highway 17 (Banks-Lowman Road). During the site inspections, which were conducted on July 19, 2021, and August 18, 2021, WCE Inc. personnel examined the Property for universal wastes, hazardous materials/wastes, and toxic wastes, including the following:

Mercury (Hg) thermostats.

Hg fluorescent lights.

PCB ballasts or transformers.

Refrigeration or A/C units containing CFCs.

Smoke detectors.

Propane containers.

Containers of liquids or hazardous waste.

Vehicle batteries.

A list of the quantity and location of each material/waste that will require removal/disposal or recycling before demolition is included in Table 1. Photographs of the materials are found in Appendix 1.

LIMITING FACTORS

This report is based upon the condition of the Property, accessibility of the structures present on the Property, and materials observed at the time of the site inspections. No samples were collected as part of the investigation. In 1996, landslide flow intruded the Property, covering much of the area around the structures and partially filling the main house with sand and rocks. Notably, the debris partially buried two 55-gallon drums in Shed 3, preventing WCE Inc. personnel from determining whether they contained hazardous materials. It should be noted that the landslide flow also may have completely buried additional debris and containers of hazardous materials so that they could not be observed from the surface. In addition to the limitations due to the landslide, several containers observed in the main house contained liquids but were unlabeled. A summary of the hazardous materials and unlabeled containers is included in Table 1.

Appendix D.

Hazardous Materials Report 2 Water, Civil, and Environmental Inc.

Table 1. Location and Amount of Hazardous Materials Observed on the Property.

Building Location Accessibility Hazardous Material DOT Hazard Class Estimated Quantity

Main House

South side, exterior

Accessible Fuel in above-ground storage tank

3, flammable 1, 300-gallon tank, partially full

Storage room on southeastern side

Largely covered by landslide flow

All-purpose alkyd enamel

3, flammable 3, 1-quart containers, full

Flat enamel paint 3, flammable 1, 1-gallon container, ⅓ full

Waterproof cement 3, flammable 1, 1-quart container, ⅓ full

Semi-transparent oil stain

3, flammable 1, 1-gallon container, ⅓ full

Interior enamel paint No DOT hazard class, but environmentally hazardous

1, 1-quart container, ½ full

Caulking compound 3, flammable 1, 11-ounce container, full

Wood finish 3, flammable 1, 1-quart container, less than ¼ full

Drain cleaner 8, corrosive material 1, 1-pint container, ¼ full

Patio furniture stain 3, flammable 1, 1-quart container, ¾ full

Latex semi-gloss enamel paint

No DOT hazard class, but environmentally hazardous

1, 1-quart container, ¼ full

Snail, slug, and insect killer bait

No DOT hazard class, but toxic to wildlife

1, 14-ounce box, less than ¼ full

Unknown Unknown 4, 15-fl oz rusted cans, full 1, 1-gallon unlabeled plastic bleach bottle, full

Kitchen/dining area

Landslide flow intrusion in dining room area

Unknown Unknown 1, 5-gallon clear plastic container, ¼ full 1, 1-pint white plastic juice jug, full

Deep gloss floor finish

No DOT hazard class, but environmentally hazardous

1, 1-gallon, less than ¼ full

Hazardous Materials Report 3 Water, Civil, and Environmental Inc.

Table 1. Location and Amount of Hazardous Materials Observed on the Property, continued.

Building Location Accessibility Hazardous Material DOT Hazard Class Estimated Quantity

Main House

Living room/ bathroom area

Landslide flow intrusion

409 spray cleaner No DOT hazard class, but environmentally hazardous

1, 12-ounce spray can, ⅕ full

Pine-Sol spray cleaner and disinfectant

Not hazardous 1, 12-ounce spray bottle, ½ full

Exterior, north side

Accessible K-57 septic tank & cesspool cleaner

Not hazardous 1, 1-pint bottle, ¾ full

Shed 3 Interior

Building is collapsed, partially buried by landslide flow

Unknown Unknown 3, 55-gallon steel drums: one partially full, two appearing to be partially full

Shed 4

Interior Accessible Unknown Unknown 1, 1-gallon plastic container, ⅓ full

Exterior, south side

Accessible Chevron Duraplex Grease

No DOT hazard class, but level 3 acute toxicity for aquatic environments

1, 5-gallon bucket, partially full

Hazardous Materials Report 4 Water, Civil, and Environmental Inc.

CONCLUSION

WCE Inc. has performed a hazardous materials inspection of the Gloria Ford Property, located along Highway 17 in Boise County, Idaho. WCE Inc. recommends that the hazardous materials observed be removed and disposed of properly before demolition of the structures on the Property. Additionally, the partially buried 55-gallon drums should be unearthed and any unidentified substances in them and in the other unlabeled containers observed should be characterized and properly disposed of.

APPENDIX 1

Hazardous Materials Photographs

Figure 1: Exterior of main house, facing northwest, above-ground heating oil tank in foreground.

Figure 2: Pint of K-57 septic tank and cesspool cleaner outside of main house, full.

Figure 3: Kitchen in main house, deep gloss floor cleaner, less than ¼ full.

Figure 4: Pint plastic juice jug in kitchen of main house, full.

Figure 5: 12-oz. can of 409 spray cleaner in bathroom of main house, ⅕ full.

Figure 6: Drain cleaner, ¼ full.

Figure 7: Quart containers of all-purpose alkyd enamel, full.

Figure 8: 11-oz. container caulking compound, full.

Figure 9: One-gallon container of interior enamel paint, ½ full.

Figure 10: 14-oz box snail, slug, and insect killer, less than ¼ full.

Figure 11: Quart of patio furniture stain, ¾ full. Figure 12: Semi-transparent oil stain, ⅓ full.

Figure 13: Quart of waterproof cement, ⅓ full. Figure 14: Quart of wood finish, less than ¼ full. Figure 15: 55-gallon steel drums inside Shed 3.

Figure 16: 5-gallon container of grease in front of Shed 4, partially full.

Figure 17: Soil staining and spillage of grease. Figure 18: Unlabeled one-gallon plastic container inside Shed 4, ⅓ full