This is a Hazardous Materials Report prepared by Water, Civil, and Environmental Inc. for the U.S. Forest Service (Boise National Forest) regarding the Gloria Ford Property in Boise County, Idaho under Contract Number 1240LR21P0058.
The report documents a comprehensive hazardous materials survey conducted on July 19, 2021, and August 18, 2021. The property, located in Township 8N, Range 5E, consists of a main house, two sheds (Shed 3 and Shed 4), and associated structures. WCE Inc. personnel inspected the property for universal wastes, hazardous materials/wastes, and toxic substances, identifying numerous items requiring removal and disposal before demolition. Key findings include an above-ground 300-gallon heating oil tank (partially full), multiple containers of flammable paints and finishes (alkyd enamel, flat enamel, waterproof cement, wood finish, and patio furniture stain), a 1-pint container of corrosive drain cleaner, propane-related materials, multiple unlabeled containers of unknown liquids, environmentally hazardous cleaners (409 spray cleaner, Pine-Sol, deep gloss floor finish), pesticides (snail, slug, and insect killer bait), K-57 septic tank cleaner, Chevron Duraplex grease with aquatic toxicity concerns, and three 55-gallon steel drums in Shed 3 (partially buried by previous 1996 landslide flow). The report identifies significant limiting factors due to landslide debris that partially buried structures and likely concealed additional hazardous materials. WCE Inc. recommends proper removal and disposal of all identified hazardous materials before demolition, with particular attention to unearthing the buried drums and characterizing unlabeled containers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 260508 Questions and Answers.docx | DOCX document | |
| SF 30 Amendment 0001.pdf | ||
| Attachment 2 - Schedule of Items.xlsx | XLSX spreadsheet | |
| Attachment 3 - SOW REVISED.pdf | ||
| Attachment 8 - Wage Determination 20155503 Boise County.pdf | ||
| Attachment 4 - Site Map.pdf | ||
| Attachment 1 - Solicitation 1240LR260013 BSNF.pdf | ||
| Attachment 2 - Schedule of Items.xlsx | XLSX spreadsheet | |
| Attachment 3 - SOW.docx | DOCX document | |
| Attachment 5 - Environmental Site Assessment.pdf | ||
| Attachment 6 - Asbestos Survey.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous Materials Report 1 Water, Civil, and Environmental Inc.
Gloria Ford Property August 23, 2021
514 NORTH 16TH STREET
BOISE, IDAHO 83702
(208) 319-9744
EMAIL: LELDRIDGE@WCE-INC.COM
August 23, 2021
R. Brett Barry, P.E.
Supervisory Civil Engineer Forest Service Boise National Forest 1249 S. Vinnell Way, Suite 200 Boise, ID 83709
Re: Gloria Ford Property Hazardous Materials Report, Contract Number 1240LR21P0058
Dear Mr. Barry:
Water, Civil, and Environmental Inc. (WCE Inc.) has conducted a hazardous materials survey to identify potentially hazardous materials associated with the Gloria Ford Property, located in Township 8N, Range 5E Section 2, Lots 9, 12, and 13 and Section 11, Lots 3 and 6 (herein referred to as the “Property”). The Property is accessible from State Highway 17 (Banks-Lowman Road). During the site inspections, which were conducted on July 19, 2021, and August 18, 2021, WCE Inc. personnel examined the Property for universal wastes, hazardous materials/wastes, and toxic wastes, including the following:
Mercury (Hg) thermostats.
Hg fluorescent lights.
PCB ballasts or transformers.
Refrigeration or A/C units containing CFCs.
Smoke detectors.
Propane containers.
Containers of liquids or hazardous waste.
Vehicle batteries.
A list of the quantity and location of each material/waste that will require removal/disposal or recycling before demolition is included in Table 1. Photographs of the materials are found in Appendix 1.
LIMITING FACTORS
This report is based upon the condition of the Property, accessibility of the structures present on the Property, and materials observed at the time of the site inspections. No samples were collected as part of the investigation. In 1996, landslide flow intruded the Property, covering much of the area around the structures and partially filling the main house with sand and rocks. Notably, the debris partially buried two 55-gallon drums in Shed 3, preventing WCE Inc. personnel from determining whether they contained hazardous materials. It should be noted that the landslide flow also may have completely buried additional debris and containers of hazardous materials so that they could not be observed from the surface. In addition to the limitations due to the landslide, several containers observed in the main house contained liquids but were unlabeled. A summary of the hazardous materials and unlabeled containers is included in Table 1.
Appendix D.
Hazardous Materials Report 2 Water, Civil, and Environmental Inc.
Table 1. Location and Amount of Hazardous Materials Observed on the Property.
Building Location Accessibility Hazardous Material DOT Hazard Class Estimated Quantity
Main House
South side, exterior
Accessible Fuel in above-ground storage tank
3, flammable 1, 300-gallon tank, partially full
Storage room on southeastern side
Largely covered by landslide flow
All-purpose alkyd enamel
3, flammable 3, 1-quart containers, full
Flat enamel paint 3, flammable 1, 1-gallon container, ⅓ full
Waterproof cement 3, flammable 1, 1-quart container, ⅓ full
Semi-transparent oil stain
3, flammable 1, 1-gallon container, ⅓ full
Interior enamel paint No DOT hazard class, but environmentally hazardous
1, 1-quart container, ½ full
Caulking compound 3, flammable 1, 11-ounce container, full
Wood finish 3, flammable 1, 1-quart container, less than ¼ full
Drain cleaner 8, corrosive material 1, 1-pint container, ¼ full
Patio furniture stain 3, flammable 1, 1-quart container, ¾ full
Latex semi-gloss enamel paint
No DOT hazard class, but environmentally hazardous
1, 1-quart container, ¼ full
Snail, slug, and insect killer bait
No DOT hazard class, but toxic to wildlife
1, 14-ounce box, less than ¼ full
Unknown Unknown 4, 15-fl oz rusted cans, full 1, 1-gallon unlabeled plastic bleach bottle, full
Kitchen/dining area
Landslide flow intrusion in dining room area
Unknown Unknown 1, 5-gallon clear plastic container, ¼ full 1, 1-pint white plastic juice jug, full
Deep gloss floor finish
No DOT hazard class, but environmentally hazardous
1, 1-gallon, less than ¼ full
Hazardous Materials Report 3 Water, Civil, and Environmental Inc.
Table 1. Location and Amount of Hazardous Materials Observed on the Property, continued.
Building Location Accessibility Hazardous Material DOT Hazard Class Estimated Quantity
Main House
Living room/ bathroom area
Landslide flow intrusion
409 spray cleaner No DOT hazard class, but environmentally hazardous
1, 12-ounce spray can, ⅕ full
Pine-Sol spray cleaner and disinfectant
Not hazardous 1, 12-ounce spray bottle, ½ full
Exterior, north side
Accessible K-57 septic tank & cesspool cleaner
Not hazardous 1, 1-pint bottle, ¾ full
Shed 3 Interior
Building is collapsed, partially buried by landslide flow
Unknown Unknown 3, 55-gallon steel drums: one partially full, two appearing to be partially full
Shed 4
Interior Accessible Unknown Unknown 1, 1-gallon plastic container, ⅓ full
Exterior, south side
Accessible Chevron Duraplex Grease
No DOT hazard class, but level 3 acute toxicity for aquatic environments
1, 5-gallon bucket, partially full
Hazardous Materials Report 4 Water, Civil, and Environmental Inc.
CONCLUSION
WCE Inc. has performed a hazardous materials inspection of the Gloria Ford Property, located along Highway 17 in Boise County, Idaho. WCE Inc. recommends that the hazardous materials observed be removed and disposed of properly before demolition of the structures on the Property. Additionally, the partially buried 55-gallon drums should be unearthed and any unidentified substances in them and in the other unlabeled containers observed should be characterized and properly disposed of.
APPENDIX 1
Hazardous Materials Photographs
Figure 1: Exterior of main house, facing northwest, above-ground heating oil tank in foreground.
Figure 2: Pint of K-57 septic tank and cesspool cleaner outside of main house, full.
Figure 3: Kitchen in main house, deep gloss floor cleaner, less than ¼ full.
Figure 4: Pint plastic juice jug in kitchen of main house, full.
Figure 5: 12-oz. can of 409 spray cleaner in bathroom of main house, ⅕ full.
Figure 6: Drain cleaner, ¼ full.
Figure 7: Quart containers of all-purpose alkyd enamel, full.
Figure 8: 11-oz. container caulking compound, full.
Figure 9: One-gallon container of interior enamel paint, ½ full.
Figure 10: 14-oz box snail, slug, and insect killer, less than ¼ full.
Figure 11: Quart of patio furniture stain, ¾ full. Figure 12: Semi-transparent oil stain, ⅓ full.
Figure 13: Quart of waterproof cement, ⅓ full. Figure 14: Quart of wood finish, less than ¼ full. Figure 15: 55-gallon steel drums inside Shed 3.
Figure 16: 5-gallon container of grease in front of Shed 4, partially full.
Figure 17: Soil staining and spillage of grease. Figure 18: Unlabeled one-gallon plastic container inside Shed 4, ⅓ full