This is an architectural floor plan document (Sheet A-101) depicting the layout of a building or facility with multiple functional spaces. The plan shows a comprehensive facility design spanning columns A through H with six floors or levels, displaying various classrooms, offices, and support spaces distributed throughout the structure.
The facility includes multiple QTP (Qualified Training Program) classrooms, OTP (On-the-Job Training Program) classrooms, CUT classrooms, and AFETs (Advanced Facilities Engineering Training System) instructional spaces ranging from 181 to 711 square feet. Support spaces include administrative areas such as an Office, Chief's Office, Break Room, Men's and Women's Latrines, Boiler Room, Conference Room, and Development Area. The electrical plan legend indicates three fixture types: T12U 40W troffers (standard fluorescent fixtures), surface mount incandescent lighting in the boiler room, and T12U 40W troffer emergency lights distributed throughout the facility. The document appears to be a detailed design specification for a training or educational facility with integrated electrical and architectural planning, suitable for federal contracting documentation related to facility construction, renovation, or maintenance requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| QnA - Lighting Installation for B704 - FA449726Q0020.pdf | ||
| Combined Synopsis_Solicitation Updated.pdf | ||
| Combined Synopsis_Solicitation.pdf | ||
| Combined Synopsis - Solicitation.pdf | ||
| Attachment 1_SOW.pdf | ||
| Attachment 2 _ Quote Schedule.xlsx | XLSX spreadsheet | |
| Attachment 3_Provisions and Clauses.pdf | ||
| Attachment 5_52.212-2, Evaluation Addendum.pdf | ||
| Attachment 6 _Wage Determination.pdf | ||
| Attachment 4_52.212-1, Instructions to Offerors Addendum.pdf | ||
| Attachment 8_B704 Lighting Requirements.pdf | ||
| Attachment 9_B704 Photometric Study.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B C D E F G H
QTP OTP Classroom Classroom st[lJ □ □ □ □ □ □ □ IIIII �Classroom □ □ □ □ QTP□room □ □ OTP Classroom QTP Classroom
Women ChiefAGT
Office Shift Chief CUT Classroom Mens Latrine Office Break RM
□ □ □ □ Latrine
□ 263 Sq Ft IIIID □ □ □ □ IIIID 189 Sq Ft 261 Sq Ft
□ □ □ mm mm □ □ □ □ 290 Sq Ft 290 Sq Ft
341 Sq Ft 327 Sq Ft 188 Sq Ft M mm □ □ □ □ □ □ □ □ □ □ □ mm □ □ □ □ □ □
□ □ □ mm □ □ mm □ □ mm mm □ OTP Classroom
□ Instructor
□ mm □ □ mmAFETs Classroom AFETs Office OTP Classroom CUT Classroom Conference RM
Development
OTP Classroom OTP Classroom
3 □ □ □ □ □ □ □ □ □ Area
□ □ □ □ □ 375 Sq Ft 437 Sq Ft □ 349 Sq Ft 711 Sq Ft 263 Sq Ft
382SqFt
181 Sq Ft
449 Sq Ft 382 Sq Ft
382 Sq Ft
□ -T12U 40W TROFFER
0 -SURFACE MOUNT INCANDESCENT IN BOILER RM
■ -T12U 40W TROFFER EMERGENCY LIGHTS
'-----------�----------�---------�--------------r-------------------------r-------------.-----------,------� A B C D E F G H
"""'1X<C\ra9"
"'E z �
�2
- Q
> E 0 w CJ
I
'"7;-
C. • .; II
l Jl� £5
� S! m i!i I!! a: " " i!i a:
s::t c:::
oO 1'--Q (9 ....J
0LL
....J al� -
[SHEET NO.
A-101
[�r
EN
File details come from the government source that posted it. Updated .