This document provides details for a federal contract opportunity to repair metal roof panels at an Air Force facility. The solicitation number is FA489724R0003 and interested vendors must register for a site visit by March 5, 2024 at 3:00PM MST in order to attend the in-person site visit scheduled for March 7, 2024 at 1:00PM MST. Questions regarding the opportunity are due by March 12, 2024 at 1:00PM MST and proposals must be submitted by March 21, 2024 at 3:30PM MST to the Department of the Air Force Air Combat Command. The attached roof report PDF provides additional technical specifications for the metal roof panel repair work required at the Air Force facility.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Proposal
02370/02371-FITNESS CENTER
365 Aardvark Ave 385 Aardvark Ave
Mountain Home AFB, ID 83648
Inspection Date: Friday, June 8, 2012
02370/02371-FITNESS CENTER Proposal
Mountain Home AFB Page 2
Building & Job Summary
Building Name 02370/02371-FITNESS CENTER
Building Address 365 Aardvark Ave 385 Aardvark Ave Mountain Home AFB, ID 83648
Year Built 1958
Roof Area (total) 82,810 SF
Building Description
Inspection Date Friday, June 8, 2012
Inspector Inspector 2399 not found
Inspection Notes
Building Contact
Client Contact
Mountain Home AFB Page 3
Section Key Plan
Mountain Home AFB Page 4
Section Information Section ID: J - northeast
Area: 8,879 SF
Roof Type: Metal Layers:
● Metal surface:
○ Material: Steel
○ Type: Architectural panel
○ Profile: Standing seam
○ Color: Beige
○ Coating: Kynar
Roof Condition Score: 90 (Adequate)
Section ID: J - northeast (Photo #2)
Area: 8,879 SF
Section ID: J - northeast (Photo #3)
Section ID: J - northeast (Photo #4)
Mountain Home AFB Page 5
Section ID: J - northeast (Photo #5)
Section ID: J - northeast (Photo #6)
Section ID: J - northeast (Photo #7)
Section ID: J - northeast (Photo #8)
Section J
Mountain Home AFB Page 6
Mountain Home AFB Page 7
Section Summary – J
Section ID: J - northeast
Year Installed: 2002 (approximate)
Height: 20 FT
Floors: 0
Sensitivity: Low
Roof Condition Score: 90 (Adequate)
Roof Type: Metal
Layers:
● Metal surface:
○ Material: Steel
○ Type: Architectural panel
○ Profile: Standing seam
○ Color: Beige
○ Coating: Kynar
Notes: None
Mountain Home AFB Page 8
Inventory Detail – Section J Segment
Raised edge
Segment
Drip edge
Segment
Cladding
Segment
Drip edge
Segment
Wall counter flashing
Segment
Cladding
Pipe vent
● Size: 2"
● Material: PVC
● Flashing: Rubber boot
Mountain Home AFB Page 9
Pipe vent
● Size: 2"
Pipe vent
● Size: 2"
Pipe vent
● Size: 4"
Mountain Home AFB Page 10
Roof Condition Score – Section J # Question (Max Value) / Notes Score 1 Roof is less than 5 years old and in excellent condition - no observed deficiencies (0) 2 Are there roof leaks? (5) 3 Have the past roof leaks caused significant interior damage? (10) 4 Have roof leaks caused significant damage to building's structural integrity? (10) 5 Has the roof been leaking for over 1 year? (7) 6 Does the roof leak every time it rains in 3 or fewer places? (5) 7 Does the roof leak every time it rains in 4 or more places? (10) 8 Is the surface of the roofing deteriorated excessively? (4) 9 Is there excessive patching on the roof? (8)
10 Is roof-top equipment mounted improperly? (5) 11 Is roof installation workmanship of medium quality? (3) 12 Is roof installation workmanship of poor quality? (5) 13 Remaining roof life > 75% (5) 14 Remaining roof life 50% - 74% (10) 10 15 Remaining roof life 25% - 49% (20) 16 Remaining roof life <25% (30) 17 Does the flashing look deteriorated and appear to be letting the water enter the building in a few places? (6)
18 Does the flashing look deteriorated and appear to be letting the water enter the building in an excessive number of places? (10)
19 Is exposed sealant showing signs of moderate deterioration? (3) 20 Is exposed sealant showing signs of excessive deterioration? (5) 21 Is there a moderate number of metal coating defects? (3) 22 Is there an excessive number of metal coating defects? (5) 23 Is there a moderate number of loose or missing fasteners? (3) 24 Is there an excessive number of loose or missing fasteners? (5) 25 Is there a moderate number of end lap defects (eave termination/transverse joints)? (3) 26 Is there an excessive number of end lap defects (eave termination/transverse joints)? (5) 27 Are the joints in the metal open to let water enter? (2) 28 Is sheet metal loose and or missing? (3) 29 Is the roof slope less than 3 in 12? (2) 30 Miscellaneous and other conditions - Low (5) 31 Miscellaneous and other conditions - Medium (10) 32 Miscellaneous and other conditions - High (15) 33 Roof is at the end of its life - Immediate Action Required! (0)
Total 10 FINAL SCORE (100 – Total) 90 ROOF CONDITION SCORE: Adequate
Mountain Home AFB Page 11
Photo Album
Building Photo
Mountain Home AFB Page 12
Mountain Home AFB Page 13
Section J: northeast
Mountain Home AFB Page 14
Mountain Home AFB Page 15
Mountain Home AFB Page 16
| Proposal |
| Inspection Date: |
| Building & Job Summary |
| Section Key Plan |
| Section Information |
| Section J |
| Section Summary – J |
| Inventory Detail – Section J |
| Roof Condition Score – Section J |