This is a Statement of Work (SOW) for the 60th Medical Group at Travis AFB, California, detailing an audiovisual (AV) system upgrade and installation for their Simulation Center, dated 29 July 2025. The project requires a comprehensive replacement of existing AV equipment across multiple training rooms, including ceiling and wall-mounted cameras, microphones, speakers, monitors, and control room workstations.
Key technical requirements include installing HD 4-megapixel PTZ cameras with 10x optical zoom, high-quality ceiling microphones, 48-inch 4K monitors, and a new operating system for recording and managing training sessions. The system must be compatible with specific medical training manikins from Laerdal, Elevate, and Gaumard. The contractor will be responsible for removing existing equipment, providing installation, customer training, a user guide, and a one-year workmanship warranty. The installation must be completed within 60 days of contract award, with work performed by a certified electrical technician, and conducted between 8:00 a.m. and 4:30 p.m. Monday through Friday at the 60th Medical Group Simulation Center.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
60th Medical Group, Travis AFB CA
Simulation Center Audiovisual System
Upgrade and Installation Services
29 July 2025
1. REQUIREMENT:
1.1. The contractor shall upgrade, install, remove, and provide training on a complete Audio-Visual (AV) system. Replacing the current AV equipment (including but not limited to displays, microphones, speakers, cameras, controllers, switches, Video Graphics Array (VGA) & High-Definition Multimedia Interface (HDMI) drops, overhead speakers/microphones, monitors, recording, playback & storage operating system workstation) in the 60 Medical Group (MDG) Simulation Center.
2. SCOPE OF WORK:
2.1. Contractor shall provide all management, tools, supplies, equipment, transportation, and qualified personnel necessary to complete the AV system upgrade.
2.2. Contractor shall provide customer training for operation of fully functional AV system. This will include a typed user guide with step-by-step instructions, graphics, and photos to aid in understanding system operations and use.
2.3. The Contractor shall provide an operating system (software) that will control the live view and save continuous recording of clips and audios from cameras and microphones to be installed in the training rooms.
2.4. The Contractor shall remove existing AV equipment listed below. Removed items shall be returned to owner for disposal.
2.4.1. Overhead speaker/microphone system
2.4.1.1. Ceiling mount speaker in training rooms connected to control room workstations
2.4.1.2. Ceiling mount microphone in training rooms connected to control room workstations
2.4.1.3. Overhead speaker/microphone system from control rooms
2.4.1.4. Microphones from training rooms connected to control rooms operating systems, ceiling mounted
2.4.2. Cameras from training rooms connected to control rooms operating systems, wall & ceiling mounted
2.4.3. Wall mounted monitors from control rooms
3. WORK DESCRIPTION
3.1. The Contractor shall deliver and install an AV system. All equipment and installation shall meet 60 MDG specifications.
3.2. The Contractor shall provide the following materials as part of the AV System:
3.2.1. Ceiling and Wall Mounted Cameras (Replacing: Axis P5534 60Hz and Axis
P5512 60Hzl).
a. Salient Characteristics/Specifications
i. High Definition (HD) 4 Mega Pixels (MP) with Pan-Tilt-Zoom
(PTZ) capability that shall be controlled through the operating system.
ii.10x Optical Zoom
iii. Continuous 360 pan
iv. Two-way audio
b. Ceiling and wall mounted cameras specific to training rooms
i. Training Rm 3G 1A619
1. Two (2) ceiling mounted cameras to include ceiling mounts as necessary.
2. One (1) wall mounted camera to include wall mount as necessary.
3. The camera viewing and recordings must be connected and stored to Workstation-1 Control Rm-1 1A618 monitor.
ii. Training Rm ALS 1A616
1. One (1) ceiling mounted camera to include ceiling mount as necessary.
2. One (1) wall mounted camera to include wall mount as necessary.
3. The camera viewing and recordings must be connected and stored to Workstation-2 Control Rm-1 1A618 monitor.
3.2.2. Ceiling Mounted Microphones (Replacing: MXL FR-401M and Audio-technica Cardioid PRO-44)
a. Salient Characteristics/Specifications
i. High-quality and clear audio
ii. Frequency: 70-16,000 Hz
iii. Open Circuit Sensitivity: -25 dB (56.2 mV) re 1V at 1 Pa
iv. Maximum Input Sound Level: 114 dB SPL, 1 kHz at 1%
T.H.D.
v. Dynamic Range (typical): 86 dB, 1 kHz at Max SPL
vi. Phantom Power Requirements: 9-52V, 2 mA typical
b. Microphones specific to training rooms
i. Training Rm 3G 1A619
1. One (1) ceiling mounted microphone above patient bed connected to Workstation-1 Control Rm-1 1A618
ii. Training Rm ALS 1A616
1. One (1) ceiling mounted microphone in the center of room connected to Workstation-2 Control Rm-1 1A618
3.2.3. Control Rooms Workstations Operating System (Replacing: CAE
Healthcare Learning Space)
a. Salient Characteristics/Specifications
i. Must have a remote recording capability
ii. Must be capable to start and stop recordings from the Control Rooms Workstations
iii. Needs to have the ability of recording the simulators vital signs monitor/image that is being displayed either with a video cable or HDMI connection
iv. Needs to accept a display input from the simulators vital signs monitor/tablet when recording the training session from the new cameras, microphone & speaker.
v. Must be capable to pan, tilt and zoom each camera to capture different angles and hone on specific details
vi. Must be able capture content from different sources, such as vital sign monitors and automatically pair it with video camera footage
vii. Must be able to mark specific moments within recordings to review and discuss with staff or students using bookmark and note-taking capabilities.
viii. Must have a centralized storage system for video recovery and or playback
ix. Must have the ability to retrieve recordings from external laptop via Wi-Fi or direct connect between Classroom-1 1A622 and Classroom-2 1A651
xx. Must be compatible with the following Manikins:
- Laerdal: 3G, SimMan ALS, and SimMom
- Elevate (CAE): Apollo Pre-Hospital
- Gaumard: Obstetric Victoria
b. The system shall not be connected to military or facility network
c. Centralized storage system shall be housed in Control Room-1 1A618
d. Classroom-1 1A622 & Classroom-21A651 monitors must be able to access recordings or playback from laptop or tablet utilizing HDMI connection to classroom podiums for projector display
i. Connection to Centralized Storage system needs to be either through internal Wi-Fi or CAT-6 or similar for a direct connection
ii. Connection or access to Centralized Storage system shall not be connected to the military or facility networks
iii. Must be able to support internal router for Wi-Fi between Control Rooms & Classrooms near the podiums
3.2.4. Two (2) Control Room Monitors
a. Salient Characteristics/Specifications
i. Size: 48” (No greater)
ii. Resolution: 4K (2160p)
iii. Must include all accessories and cabling to connect to cameras, microphones, and operation system for viewing.
b. Monitor Locations
i. One (1) at Workstation-1 in Control Rm-1 1A618
ii. One (1) at Workstation-2 in Control Rm-1 1A618
c. Must be mounted to Wall Mounts specified in Section 3.2.5.
3.2.5. Two (2) Full Motion TV Wall Mounts
a. Specifications
i. Must support 48” monitor
b. Must be mounted at Workstations specified in Section 3.2.4.b.
3.2.6. Overhead Speakers (Replacing: Brand Name JBL)
a. Salient Characteristics/Specifications
i. Frequency Range (-10 dB): 80 Hz - 20 kHz
ii. Power Capacity: 80 Watts Continuous Program Power ; 40
Watts Continuous Pink Noise
ii. Must be able to provide clear live audio output from microphones
ii. Volume controls must be connected and operated for adjustment through the Operating System
b. Overhead Speakers specific to training rooms
i. Training Rm 3G 1A619
1. One (1) ceiling mounted speaker above patient bed connected to Workstation-1 Control Rm-1 1A618
ii. Training Rm ALS 1A616
1. One (1) ceiling mounted speaker in the center of room connected to Workstation-2 Control Rm-1 1A618
3.2.7. HDMI/VGA Video Links – Two (2) cables
a. Specifications:
i. Must support 4K resolution
ii. Fully implements High-bandwidth Digital Content Protection
(HDCP) standard
iii. Must be able to connect the HDMI/VGA from Control Rooms workstations to Training Rooms
b. Change VGA drop plates from single to double for added HDMI Access
4. INSTALLATION AND DELIVERY
4.1. The contractor must coordinate with 60 MDG Point of Contact (POC) prior to delivery and start of installation. Installation must be completed within 60 days ARO.
4.2. Place of Delivery and Installation: 60th Medical Group Simulation Center, 101 Bodin Circle, Travis AFB, CA
4.3. All work shall be completed between 8:00 a.m. And 4:30 p.m. Monday – Friday.
4.4. The contractor shall coordinate all deliveries, installations, and parking arrangements with the POC.
4.5. The contractor shall be responsible for any damage to the building that occurs due to contractor error or neglect.
5. ELECTRICAL INFORMATION:
5.1. Contractor is able to utilize existing conduits or raceways.
5.2. Contractor is able to utilize existing drops and pathways from Control Rooms to Training Rooms.
6. WARRANTY:
6.1. Contractor shall guarantee workmanship for a period of one (1) year after acceptance of work.
6.2. Contractor shall disclose and furnish any manufacturer’s warranty(s) and specification required warranty(s) greater than one year.
7. ADDITIONAL DELIVERABLES
7.1. Operation and Maintenance Manuals
1. Binders - Quantity (1) for each equipment item.
2. Digital Copies- Quantity (1) for each equipment item.
8. OPERATOR TRAINING:
7.1. Contractor shall provide on-site training of the equipment to three (3) Staff members. Scheduling of operator training shall be coordinated with the Simulation Center POC after installation is complete. Training shall include basic operation and trouble shooting.
9. CERTIFICATION/LICENSING: All work shall be performed by a certified electrical technician, specifically qualified and trained to provide audio video and programming to meet the government requirement.
10. SIMULATION CENTER FLOORPLAN
Trng Rm
CCATT
1A623
Storage
Coordinator Office 1A614
Control Rm-2
1A621
Outside Patio for Training & EMEDS Tent
Control Rm-1
1A618
GENESIS
Simulator Storage
Trng Rm Trauma 1A624
Classroom-
1A622
Classroom-2 1A651
Trng Rm 3G
1A619 Trng Rm
ALS
1A616
Storage Storage Supply Room
Moulage
Operators Office 1A627
VR Trainers 1A609
VA
Out-Patient
Office
11. Point of Contact: Mr. Daniel Dettwiler- Travis AFB 707-423-3751