Attachment 3(b) HazMaterial Survey Birmingham EHRM 09-01-2022_Part_2_of_2.pdf
PDF 5 MB Posted
- Attached to
- EHRM Birmingham Infrastructure Upgrades
- Solicitation number
- 36C77623B0026
About this file
This document outlines a federal contract opportunity for infrastructure upgrades at the Veterans Affairs Medical Center in Birmingham, Alabama. The contractor shall provide all labor, materials, project management and quality control services to complete Electronic Health Records Modernization upgrades. This is a firm-fixed-price contract issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The solicitation number is 36C77623B0026 and the contractor must upgrade infrastructure to support the implementation of a new EHRM system at the Birmingham VAMC facility.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIXTH FLOOR ROOF
FOURTH FLOOR ROOF
FOURTH FLOOR ROOF
129 SF / 12 m²
153 SF / 14.2 m²
PRIMARY CARE
RESTROOM
130 SF / 12.1 m²
MEDICINE SERVICE
INTERNAL MEDICINE
ATTENDING
114 SF / 10.6 m²
PRIMARY CARE
STOR
152 SF / 14.2 m²
MEDICINE SERVICE
CHIEF MEDICAL
RESIDENT
153 SF / 14.2 m²
MEDICINE SERVICE
SPECIALTY CARE MANAGER
137 SF / 12.7 m²
MEDICINE SERVICE
ADMINISTRATIVE
OFFICE
136 SF / 12.6 m²
MEDICINE
SERVICE
RHEUMATOLOGY
HEMATOLOGY/ONCOLOGY
138 SF / 12.8 m²
SURGICAL
OFF
124 SF / 11.5 m²
SURGICAL
OFF
119 SF / 11 m²
TUMOR REGISTRAR
141 SF / 13.1 m²
SURGICAL
OFF
260 SF / 24.2 m²
CHIEF
SURGICAL
SERVICE
136 SF / 12.7 m²
ADMINISTRATIVE
OFFICES
108 SF / 10 m²
SECRETARY CHIEF
SURGICAL SVC
225 SF / 20.9 m²
RENAL TRANSPLANT
143 SF / 13.3 m²
HEALTHCARE ADMIN SVC
OFF
159 SF / 14.8 m²
MEDICINE SERVICE MEDICAL
SUPPORT ASSISTANTS
297 SF / 27.6 m²
PRIMARY CARE
CONF RM
191 SF / 17.7 m²
PRIMARY CARE
EXAM RM
205 SF / 19.1 m²
PRIMARY CARE
ACOS PRIMARY AND COMMUNITY
BASED MED
251 SF / 23.4 m²
PRIMARY CARE
DIR-PRIMARY CARE
186 SF / 17.3 m²
MEDICINE SERVICE
PROVIDERS
208 SF / 19.4 m²
CENTRL STAFF FAC
MENS PUBLIC/STAFF TLT
149 SF / 13.8 m²
CENTRL STAFF FAC
WOMENS PUBLIC/STAFF TLT
64 SF / 5.9 m²
PRIMARY CARE
PCMM
COORDINATOR/PROGRAM
SPECIALIST
55 SF / 5.1 m²
PRIMARY CARE
TLT
7234A
180 SF / 16.7 m²
PRIMARY CARE
ADMINISTRATIVE
OFFICES/PHARMASIST
90 SF / 8.4 m²
COMMON
COPY
258 SF / 24 m²
VERTICAL SPACE
STAIR-3
RCC703R 111 SF / 10.3 m²
COMMON
ELECTRO MECH
38 SF / 3.5 m²
TELECOM
63 SF / 5.9 m²
SURGICAL
FILES
36 SF / 3.4 m²
JANITOR
232 SF / 21.5 m²
POLICE
ADMINISTRATION
VEHICLE
REGISTRATION
144 SF / 13.4 m²
INFECTION
PREVENTION AND
CONTROL OFF
147 SF / 13.6 m²
INFECTION PREVENTION
AND CONTROL OFF
153 SF / 14.2 m²
MILLION VETERAN
PROGRAM
OFF
128 SF / 11.9 m²
STUDY
NURSE
COORDINATOR
138 SF / 12.8 m²
NEUROLOGY HEADACHE
SERVICES
119 SF / 11.1 m²
VA POLICE
TRAINING OFFICER
127 SF / 11.8 m²
SPEC CARE
EMG EXAM
185 SF / 17.2 m²
SPEC CARE
EEG EXAM RM
225 SF / 20.9 m²
SPEC CARE
NEUROLOGY RESS
142 SF / 13.2 m²
SPEC CARE
ADMINSTRATIVE OFF
95 SF / 8.8 m²
SPEC CARE
CPAP EDUCATORS
151 SF / 14 m²
SPECIAL CARE
SLEEP
SUITE 3
74 SF / 6.9 m²
SPEC CARE
BATH
7121A
159 SF / 14.7 m²
SPECIAL CARE
SLEEP
SUITE 2
157 SF / 14.6 m²
SPEC CARE
SLEEP
SUITE 1
93 SF / 8.7 m²
STORAGE
92 SF / 8.6 m²
SPEC CARE
ANTE TLT
76 SF / 7.1 m²
SPEC CARE
BATH
7125A
179 SF / 16.6 m²
SPEC CARE
SLEEP
SUITE 6
163 SF / 15.1 m²
SPEC CARE
SLEEP
SUITE 5
127 SF / 11.8 m²
SPEC CARE
EXAM RM 1
248 SF / 23 m²
SPEC CARE
CONTROL RM
164 SF / 15.2 m²
SPEC CARE
TMS EXAM RM
169 SF / 15.7 m²
CLINICAL
EXAM RM 2
174 SF / 16.2 m²
SPEC CARE
NEUROLOGY PHYS
175 SF / 16.2 m²
SPEC CARE
MEN
188 SF / 17.5 m²
SPEC CARE
WOMEN
808 SF / 75 m²
COMMON
CORR
RCC737R
303 SF / 28.1 m²
CCTV ROOM
149 SF / 13.9 m²
BRC
ASSISTANT
CHIEF
OFF
135 SF / 12.5 m²
PSYCHOLOGY
OFF
129 SF / 12 m²
SBRC
ADMINISSION
COORDINATOR
OFF
154 SF / 14.3 m²
BRC CHIEF
OFFICE
430 SF / 39.9 m²
HEALTH
INFORMATION
MANAGEMENT SERV.
(HIMS)
BEDS BLIND REHAB
OFF
7612D
BEDS BLIND REHAB
OFF
7612E
HEALTH
INFORMATION
MANAGEMENT
SERVICES (HIMS)
COMMON
ELECTRO MECH
143 SF / 13.3 m²
BRC OPTOMETRIST
OFF
93 SF / 8.7 m²
BEDS BLIND REHAB
MENS TLT
128 SF / 11.9 m²
BEDS BLIND REHAB
WOMENS TLT
115 SF / 10.6 m²
PSYCHOLOGIST
OFF
118 SF / 11 m²
BEDS BLIND REHAB
OFF
156 SF / 14.5 m²
CHAPLAIN
164 SF / 15.2 m²
BEDS BLIND REHAB
OFF
135 SF / 12.6 m²
VIST COORDINATOR
OFF
225 SF / 20.9 m²
OPTOMETRY LOW
VISION EXAM
157 SF / 14.6 m²
NEAR VISION CLINIC
129 SF / 11.9 m²
OPTOMETRY LOW
VISION EXAM RM
58 SF / 5.4 m²
MAIL ROOM
75 SF / 7 m²
LIVING SKILLS
83 SF / 7.7 m²
LIVING SKILLS
127 SF / 11.8 m²
BRC SUPERVISOR
112 SF / 10.4 m²
LIVING SKILLS
74 SF / 6.9 m²
LIVING SKILLS
75 SF / 7 m²
BRC COMPUTER
TRAINING RM 3
74 SF / 6.9 m²
BRC COMPUTER
TRAINING RM 2
75 SF / 7 m²
BRC COMPUTER
TRAINING RM 1
BEDS BLIND REHAB
STOR
104 SF / 9.7 m²
VERTICAL SPACE
ELEV 9
RCC715R
102 SF / 9.5 m²
VERTICAL SPACE
ELEV 8
RCC716R
45 SF / 4.2 m²
VERTICAL SPACE
CHASE
RCC701C
191 SF / 17.8 m²
VERTICAL SPACE
STAIR-10
RCC709R
47 SF / 4.4 m²
COMMON
HAC
674 SF / 62.6 m²
COMMON
ELECTRO MECH
237 SF / 22 m²
VERTICAL SPACE
ELEV MACH AREA
RCC714R
265 SF / 24.7 m²
VERTICAL SPACE
ELEV PENTHOUSE
RCC713R
97 SF / 9 m²
VERTICAL SPACE
ELEV 10
RCC725R
183 SF / 17 m²
VERTICAL SPACE
STAIR-12
RCC705R
55 SF / 5.1 m²
COMMON
IT
195 SF / 18.2 m²
POLICE/SEC
OFF
137 SF / 12.8 m²
POLICE/SEC
OFF
126 SF / 11.7 m²
POLICE/SEC
OFF
23 SF / 2.1 m²
POLICE/SEC
CLO
203 SF / 18.9 m²
VOLUNTARY
SERVICE
STORAGE
125 SF / 11.6 m²
VSO/VET/UNION
UNION-OFF
7320A 137 SF / 12.7 m²
VSO/VET/UNION
UNION-OFF
7320B
14 SF / 1.3 m²
VSO/VET/UNION
UNION-OFF
7320A-A
307 SF / 28.6 m²
INFECTION PREVENTION AND
CONTROL OFF
27 SF / 2.5 m²
COMMON
ELECTRO MECH
83 SF / 7.7 m²
VERTICAL SPACE
ELEV 1
RCC726R
99 SF / 9.2 m²
VERTICAL SPACE
ELEV 2
RCC720R
52 SF / 4.8 m²
COMMON
WOMEN
61 SF / 5.7 m²
COMMON
MEN
60 SF / 5.5 m²
COMMON
HAC
206 SF / 19.1 m²
SPEC CARE
INFECTION CONTROL OFF
7324A
189 SF / 17.6 m²
VSO/VET/UNION
UNION-OFF
7320C
91 SF / 8.5 m²
VERTICAL SPACE
ELEV 17
RCC722R
154 SF / 14.3 m²
SPEC CARE
CRNP NEUROLOGY
STROKE COORD
146 SF / 13.6 m²
SPEC CARE
CPAP
EDUCATORS
162 SF / 15 m²
SPEC CARE
STROKE CENTER OFF
154 SF / 14.3 m²
SPEC CARE
SLEEP CLEAN SUPP
227 SF / 21.1 m²
VERTICAL SPACE
STAIR-2
RCC704R
37 SF / 3.4 m²
COMMON
HAC
40 SF / 3.7 m²
COMMON
IT
114 SF / 10.6 m²
COMMON
ELECTRO MECH
395 SF / 36.7 m²
COMMON
CORR
RCC736R
1,249 SF / 116 m²
COMMON
CORR
RCC735R
37 SF / 3.4 m²
STOR
168 SF / 15.6 m²
SPECIAL CARE
SLEEP
SUITE 4
89 SF / 8.3 m²
SPEC CARE
BATH
7123A
90 SF / 8.3 m²
SPEC CARE
BATH
7124A
26 SF / 2.4 m²
VERTICAL SPACE
CHASE
RCC702C
73 SF / 6.8 m²
SPEC CARE
BATH
7120A
21 SF / 1.9 m²
VERTICAL SPACE
CHASE
RCC703C
75 SF / 7 m²
SPEC CARE
BATH
7119A
11 SF / 1 m²
VERTICAL SPACE
CHASE
RCC704C
11 SF / 1 m²
VERTICAL SPACE
CHASE
RCC705C
194 SF / 18 m²
SPEC CARE
EMG EXAM RM
40 SF / 3.7 m²
SPEC CARE
LINEN
CLOSET
119 SF / 11 m²
SPEC CARE
SLEEP PHY
628 SF / 58.3 m²
SPEC CARE
NEUROLOGY CONF RM
107 SF / 9.9 m²
SPEC CARE
NEUROLOGY RECEPTION
259 SF / 24 m²
SPEC CARE
NEUROLOGY WAIT
96 SF / 8.9 m²
COMMON
ELECTRO MECH
32 SF / 3 m²
COMMON
IT
92 SF / 8.6 m²
VERTICAL SPACE
ELEV 4
RCC718R
81 SF / 7.5 m²
VERTICAL SPACE
ELEV 3
RCC719R
215 SF / 20 m²
VERTICAL SPACE
STAIR-1
RCC710R
489 SF / 45.4 m²
COMMON
CORR
RCC734R
46 SF / 4.3 m²
COMMON
ELECTRO MECH
7305 109 SF / 10.1 m²
VERTICAL SPACE
ELEV 5
RCC717R
1,009 SF / 93.8 m²
COMMON
CORR
RCC733R
2,081 SF / 193.4 m²
COMMON
CORR
RCC732R
153 SF / 14.3 m²
MEDICINE SERVICE INFECTIOUS
DISEASE ATTENDING
191 SF / 17.8 m²
VERTICAL SPACE
STAIR-11
RCC706R
268 SF / 24.9 m²
VERTICAL SPACE
STAIR-4
RCC702R
91 SF / 8.4 m²
VERTICAL SPACE
ELEV 18
RCC721R
81 SF / 7.5 m²
VERTICAL SPACE
ELEV 15
RCC724R
81 SF / 7.5 m²
VERTICAL SPACE
ELEV 16
RCC723R
201 SF / 18.7 m²
SPEC CARE
CHIEF OF
NEUROLOGY
1,573 SF / 146.1 m²
COMMON
RCC707R
159 SF / 14.8 m²
POLICE/SEC
CORR
RCC708R
187 SF / 17.4 m²
VERTICAL SPACE
ELEV-15
RCC712R
21 SF / 1.9 m²
VERTICAL SPACE
CHASE
RCC706C
14 SF / 1.3 m²
VERTICAL SPACE
CHASE
RCC707C
84 SF / 7.8 m²
COMMON
UTILITY STOR
10 SF / 0.9 m²
VERTICAL SPACE
CHASE
RCC708C
2 SF / 0.2 m²
COMMON
CHASE
RCC709C
10 SF / 1 m²
COMMON
CHASE
RCC710C
9 SF / 0.8 m²
COMMON
CHASE
RCC711C
9 SF / 0.8 m²
COMMON
CHASE
RCC712C
4 SF / 0.4 m²
VERTICAL SPACE
CHASE
RCC713C
19 SF / 1.8 m²
VERTICAL SPACE
CHASE
RCC714C
24 SF / 2.2 m²
VERTICAL SPACE
CHASE
RCC715C
55 SF / 5.1 m²
VERTICAL SPACE
CHASE
RCC716C
41 SF / 3.8 m²
COMMON
CHASE
RCC717C
141 SF / 13.1 m²
VSO/VET/UNION
UNION-OFF
7320D
221 SF / 20.6 m²
AFGE LOCAL 2207
UNION OFFICE
30 SF / 2.8 m²
VERTICAL SPACE
CHASE
RCC718C
13 SF / 1.2 m²
COMMON
CHASE
RCC719C
1,294 SF / 120.2 m²
COMMON
CORR
RCC731R
17 SF / 1.6 m²
COMMON
CHASE
RCC720C
148 SF / 13.8 m²
MEDICINE SERVICE ASSOCIATE SHIEF
OF STAFF
18 SF / 1.7 m²
VERTICAL SPACE
CHASE
RCC721C
15 SF / 1.4 m²
VERTICAL SPACE
CHASE
RCC722C
13 SF / 1.2 m²
VERTICAL SPACE
CHASE
RCC723C
22 SF / 2 m²
VERTICAL SPACE
CHASE
RCC724C
6 SF / 0.6 m²
COMMON
FAC
RCC711R
8 SF / 0.8 m²
VERTICAL SPACE
CHASE
RCC725C
11 SF / 1 m²
VERTICAL SPACE
CHASE
RCC726C
7 SF / 0.6 m²
VERTICAL SPACE
CHASE
RCC727C
12 SF / 1.1 m²
VERTICAL SPACE
CHASE
RCC728C
31 SF / 2.9 m²
VERTICAL SPACE
CHASE
RCC729C
36 SF / 3.3 m²
VERTICAL SPACE
CHASE
RCC730C
22 SF / 2 m²
VERTICAL SPACE
CHASE
RCC731C
16 SF / 1.4 m²
VERTICAL SPACE
CHASE
RCC732C
19 SF / 1.8 m²
COMMON
CHASE
RCC733C
48 SF / 4.5 m²
VERTICAL SPACE
CHASE
RCC734C
47 SF / 4.4 m²
VERTICAL SPACE
CHASE
RCC735C
17 SF / 1.6 m²
VERTICAL SPACE
CHASE
RCC736C
44 SF / 4.1 m²
VERTICAL SPACE
CHASE
RCC737C
62 SF / 5.8 m²
VERTICAL SPACE
CHASE
RCC738C
73 SF / 6.8 m²
COMMON
CORR
RCC730R
24 SF / 2.2 m²
NURSING SVC
ADMIN
CLO
7316A
53 SF / 4.9 m²
VERTICAL SPACE
ELEV
RCC728R
56 SF / 5.2 m²
VERTICAL SPACE
ELEV
RCC727R
93 SF / 8.6 m²
COMMON
ELECTROMECH
34 SF / 3.1 m²
VERTICAL SPACE
CHASE
RCC738R
1,788 SF / 166.1 m²
COMMON
CORR
RCC729R
151 SF / 14.1 m²
VSO/VET/UNION
CONF RM
RCC474R
MEDICINE SERVICE
INTERNAL MEDICINE
ATTENDING
BEDS BLIND REHAB
OFF
7612F
BEDS BLIND REHAB
OFF
7612A
BEDS BLIND REHAB
OFF
7612B
STORAGE
BLIND REHAB
OUTPATIENT
SPECIALIST OFF.
BLIND REHAB
OUTPATIENT CENTER
(BRC) SECRETARY
OFF.
BEDS BLIND REHAB
OFF
7612C
BEDS BLIND REHAB
OFF
TR1
160 SF
TR2
143 SF
RCP
RCP
99,100,101,1027614
109,110
SCALE: 1/16" = 1'-0"F1 7TH FLOOR PLAN LEVEL
VA Medical Center 7010 19th St. S.
Birmingham, Alabama AET Project No. P-0013087Date: 7/11/2022
Floor 07 Asbestos and Lead Sample Locations
Figure
File: X:\AMERICAN\ALABAMA\Birmingham_AL\VA_MedicalCenter\Drawings\AE107_Level_7.dwg PO 17938-1640
Legend Asbestos or Lead Sample
Positive Material
TELECOM ROOM LEGEND
EXISTING TR UPGRADED
PROPOSED NEW CABINET/TR/MCR LOCATION
ROOM CONVERTED TO FACILITY'S USE
PROPOSED EXPANSION TO TR
ccampbell EHesse AL Stamp_sign
SEVENTH FLOOR ROOF
SIXTH FLOOR ROOF
SEVENTH FLOOR ROOF
120 SF / 11.1 m²
GERIATRICS
OFF
137 SF / 12.7 m²
GERIATRICS
OFF
144 SF / 13.3 m²
ASSOCIATE
DIRECTOR
CLINICAL
PROGRAMS
OFF
8219156 SF / 14.5 m²
DIRECTOR,
MOBILITY
ASSESSMENT
OFF
121 SF / 11.3 m²
GERIATRICS
OFF
135 SF / 12.5 m²
GERIATRICS
OFF
119 SF / 11.1 m²
DIRECTOR
GERIATRIC
FELLOWSHIP
OFF
143 SF / 13.3 m²
GRECC
ADMINISTRATIVE
OFFICER
OFF
8226B 288 SF / 26.7 m²
GRECC
ADMINISTRATIVE
SUITE
OFF
8226202 SF / 18.8 m²
GRECC
DIRECTOR
OFF
8226A190 SF / 17.7 m²
GRECC EXAM
ROOM B
211 SF / 19.6 m²
GRECC EXAM
ROOM A
140 SF / 13 m²
PROJECT
COORDINATOR
OFF
135 SF / 12.5 m²
DATA
MANAGEMENT
OFF
123 SF / 11.4 m²
GERIATRICS
OFF
133 SF / 12.3 m²
GERIATRICS
OFF
144 SF / 13.4 m²
ASSOCIATE
DIRECTOR
RESEARCH
OFF
139 SF / 12.9 m²
PHYSICIAN
OFF
149 SF / 13.9 m²
PROJECT
COORDINATOR
OFF
160 SF / 14.8 m²
CHIEF
GERIATRIC
SERVICES
OFF
228 SF / 21.2 m²
GERIATRICS
OFF
135 SF / 12.5 m²
GERIATRICS
OFF
188 SF / 17.4 m²
VERTICAL SPACE
STAIR-11
RCC826R
148 SF / 13.8 m²
GERIATRICS
CONF RM
82 SF / 7.6 m²
COMMON
ELECTROMECH
51 SF / 4.8 m²
COMMON
IT
82 SF / 7.6 m²
COMMON
FILE RM
239 SF / 22.2 m²
VERTICAL SPACE
STAIR NO 3
RCC824R
169 SF / 15.7 m²
GRECC EXAM ROOM C
8202A
452 SF / 42 m²
GERIATRICS
GERIATRIC FELLOWS OFF
317 SF / 29.5 m²
GRECC CONFERENCE
ROOM
270 SF / 25.1 m²
GERIATRICS
OFFICE
36 SF / 3.4 m²
GERIATRICS
LOLOTOSHO
8231A
152 SF / 14.1 m²
WOMEN
GERIATRICS
LOLOTOSHO
187 SF / 17.4 m²
MENS
GERIATRICS
LOLOTOSHO
1,990 SF / 184.9 m²
GERIATRICS
CORR
RCC804R
81 SF / 7.5 m²
REHAB MED
LOLOTOSHO
8305C
108 SF / 10 m²
COMMON
ELECTRO MECH
8305B
233 SF / 21.7 m²
REHAB MED
GYM/TREATMENT RM
8305A
63 SF / 5.9 m²
VERTICAL SPACE
ELEV
RCC810R
63 SF / 5.9 m²
VERTICAL SPACE
ELEV
RCC811R
244 SF / 22.7 m²
COMMON
ELECTRO MECH
45 SF / 4.2 m²
COMMON
ELECTRO MECH
109 SF / 10.1 m²
VERTICAL SPACE
ELEV 5
RCC820R
20 SF / 1.8 m²
COMMON
ELECTROMECH CLO
8307A
768 SF / 71.4 m²
PM & RS
COMMON
WAIT
432 SF / 40.1 m²
BED
MANAGEMENT
& TRANSFER
OFFICE
214 SF / 19.8 m²
AUDIOLOGY
EXAM RM
213 SF / 19.7 m²
AUDIOLOGY
OFF
73 SF / 6.8 m²
AUDIOLOGY
OFF
206 SF / 19.1 m²
AUDIOLOGY
OFF
304 SF / 28.2 m²
PATIENT
FLOW/BMS
UTILIZATION
MANAGEMENT
163 SF / 15.1 m²
SURGICAL
PODIATRY-EXAM
RM
124 SF / 11.5 m²
SURGICAL
PODIATRY-CLEAN
STOR
131 SF / 12.2 m²
SPEC CARE
PODIATRY-EXAM RM / TREAT
238 SF / 22.1 m²
BEHAV HEALTH
PODIATRY OFF
159 SF / 14.8 m²
SPEC CARE
PODIATRY EXAM RM
171 SF / 15.8 m²
SPEC CARE
PODIATRY EXAM RM
125 SF / 11.6 m²
MED SVC ADMIN
OFF
8309 372 SF / 34.5 m²
SWING SPACE
OFF
8311A
165 SF / 15.3 m²
SWING SPACE
OFF
110 SF / 10.2 m²
COMMON
ELECTRO MECH
48 SF / 4.4 m²
COMMON
IT
88 SF / 8.1 m²
VERTICAL SPACE
ELEV 3
RCC818R
213 SF / 19.8 m²
VERTICAL SPACE
STAIR-1
RCC825R
1,099 SF / 102.1 m²
COMMON
CORR
RCC805R
334 SF / 31 m²
COMMON
CORR
RCC806R
80 SF / 7.4 m²
BEHAV HEALTH
COPY CENTER
1,468 SF / 136.4 m²
COMMON
CORR
RCC807R
113 SF / 10.5 m²
VOL SVC
OFF
123 SF / 11.4 m²
OUTPATIENT
SOCIAL WORK
SUPERVISOR
OFF
128 SF / 11.9 m²
INPATIENT
SOCIAL WORK
SUPERVISOR OFF
8114145 SF / 13.5 m²
COORD. & ADMIN.
OFF
57 SF / 5.3 m²
BEHAV HEALTH
STOR
138 SF / 12.8 m²
CASE
MANAGEMENT
PROGRAM
OFF
131 SF / 12.2 m²
ASSISTANT
CHIEF SOCIAL
WORK SERVICE
OFF
145 SF / 13.5 m²
ADMIN. OFFICER
OFF
119 SF / 11.1 m²
TCM PROGRAM
MANAGER
OFF
88 SF / 8.2 m²
SURGICAL
DIRTY UTIL
37 SF / 3.4 m²
COMMON
ELECTRO MECH
34 SF / 3.2 m²
SURGICAL
TLT
8137A
145 SF / 13.4 m²
SURGICAL
EXAM RM
134 SF / 12.5 m²
SURGICAL
ELECTROMECH
215 SF / 19.9 m²
PREP
ROOM
46 SF / 4.2 m²
SURGICAL
LOLOTOSHO
219 SF / 20.4 m²
SURGICAL
OFF
75 SF / 7 m²
SPS
STORAGE
125 SF / 11.6 m²
BREAK
ROOM
OFF
131 SF / 12.2 m²
SURGICAL
OFFICE
151 SF / 14 m²
SURGICAL
EXAM RM
140 SF / 13 m²
SURGICAL
EXAM RM
229 SF / 21.3 m²
VERTICAL SPACE
STAIR-2
RCC828R
244 SF / 22.7 m²
VERTICAL SPACE
STAIR-4
RCC829R
380 SF / 35.3 m²
VERTICAL SPACE
STAIR-12
RCC827R
91 SF / 8.4 m²
VERTICAL SPACE
ELEV 18
RCC816R
91 SF / 8.5 m²
VERTICAL SPACE
ELEV 17
RCC815R
77 SF / 7.1 m²
VERTICAL SPACE
ELEV 16
RCC814R
77 SF / 7.1 m²
VERTICAL SPACE
ELEV 15
RCC813R
83 SF / 7.7 m²
VERTICAL SPACE
ELEV 1
RCC812R
104 SF / 9.7 m²
VERTICAL SPACE
ELEV 2
RCC817R
31 SF / 2.9 m²
COMMON
ELECTROMECH
34 SF / 3.1 m²
VERTICAL SPACE
CHASE
RCC801C
1,099 SF / 102.1 m²
COMMON
CORR
RCC808R
152 SF / 14.1 m²
SWING SPACE
OFF
257 SF / 23.9 m²
VOL SVC
OFF
123 SF / 11.5 m²
VOL SVC
OFF
127 SF / 11.8 m²
SURGICAL
EXAM RM
122 SF / 11.4 m²
SURGICAL
OFF
142 SF / 13.2 m²
CHIEF SOCIAL
WORK SERVICES
OFF
54 SF / 5 m²
COMMON
HAC
1,069 SF / 99.3 m²
REHAB MED
STOR RM
193 SF / 17.9 m²
NEUROLOGY
ATTENDING
PHYSICIANS
RCC801R
8305D
30 SF / 2.8 m²
SURGICAL
TLT
8129A
10 SF / 0.9 m²
VERTICAL SPACE
CHASE
RCC802C
13 SF / 1.2 m²
VERTICAL SPACE
CHASE
RCC803C
5 SF / 0.5 m²
COMMON
CHASE
RCC805C
7 SF / 0.6 m²
COMMON
CHASE
RCC806C
55 SF / 5.1 m²
SURGICAL
ICE MACH
RCC823R
14 SF / 1.3 m²
COMMON
CHASE
RCC807C
26 SF / 2.4 m²
VERTICAL SPACE
CHASE
RCC808C
25 SF / 2.4 m²
VERTICAL SPACE
CHASE
RCC809C
21 SF / 1.9 m²
VERTICAL SPACE
CHASE
RCC810C19 SF / 1.8 m²
VERTICAL SPACE
CHASE
RCC811C
14 SF / 1.3 m²
COMMON
CHASE
RCC812C
54 SF / 5.1 m²
VERTICAL SPACE
CHASE
RCC813C
41 SF / 3.8 m²
VERTICAL SPACE
CHASE
RCC814C
17 SF / 1.6 m²
VERTICAL SPACE
CHASE
RCC815C
47 SF / 4.4 m²
GERIATRICS
STOR
19 SF / 1.8 m²
COMMON
HAC
16 SF / 1.5 m²
VERTICAL SPACE
CHASE
RCC818C
43 SF / 4 m²
VERTICAL SPACE
CHASE
RCC819C
59 SF / 5.5 m²
VERTICAL SPACE
CHASE
RCC820C
69 SF / 6.4 m²
COMMON
RCC803R
44 SF / 4.1 m²
VERTICAL SPACE
DUMBWAITER
RCC809R
88 SF / 8.2 m²
VERTICAL SPACE
ELEV 4
RCC819R
38 SF / 3.5 m²
VOL SVC
OFF
27 SF / 2.5 m²
COMMON
CHASE
RCC821C
228 SF / 21.2 m²
COMMON
CORR
RCC830R
547 SF / 50.9 m²
PROSTHETICS
RCC831R
SWING SPACE
OFF
TR1
77 SF
TR2
69 SF
315-4LBL-A
8302 8217
315-4GR-A
L1
106,107
SCALE: 1/16" = 1'-0"F1 8TH FLOOR PLAN LEVEL VA Medical Center 7010 19th St. S.
Birmingham, Alabama AET Project No. P-0013087Date: 7/20/2022
Floor 08 Asbestos and Lead Sample Locations
Figure
File: X:\AMERICAN\ALABAMA\Birmingham_AL\VA_MedicalCenter\Drawings\AE108_Level_8.dwg PO 17938-1640
Legend Asbestos or Lead Sample
Positive Material
TELECOM ROOM LEGEND
EXISTING TR UPGRADED
PROPOSED NEW CABINET/TR/MCR LOCATION
ROOM CONVERTED TO FACILITY'S USE
PROPOSED EXPANSION TO TR
L1 Lead containing glazing on 4"x4" tan painted green ceramic wall tiles. If renovation activities will impact the lead containing tiles the activities must be conducted by a licensed lead abatement company utilizing certified workers using negative pressure glovebag methods.
Otherwise, do not disturb, protect as necessary.
Use non-invasive surface mount system with adhesive or similar. Use existing sleeves through the tile block where present. (80 SF)
ROOF
101 SF / 9.3 m²
CONFERENCE ROOM
103 SF / 9.6 m²
NURSING SVC ADMIN
PCS STAFF OFF
81 SF / 7.5 m²
NURSING SVC ADMIN
WAIT
202 SF / 18.8 m²
NURSING SVC ADMIN
ASSOCIATE DIRECTOR,
PCS OFF
9304G 165 SF / 15.3 m²
NURSING SVC ADMIN
SECRETARY OFF
9304F
153 SF / 14.2 m²
NURSING SVC ADMIN
CHIEF NURSE CRITICAL
CARE OFF
9304H
158 SF / 14.7 m²
NURSING SVC ADMIN
CHIEF NURSE /
MEDICINE OFF
9304I
132 SF / 12.2 m²
NURSING SVC ADMIN
CHIEF NURSE/OUT
PATIENTS & STAFF
DEVELOPMENT OFF
9304J
144 SF / 13.3 m²
NURSING SVC
ADMIN
COPIER
9304C
196 SF / 18.2 m²
NURSING SVC ADMIN
CHIEF PATIENT CARE
SERVICES OFF
9304B
127 SF / 11.8 m²
ADMINISTRATIVE
OFFICER, PCS
OFF
9305B
204 SF / 19 m²
PCS TIME KEEPING
NURSE COORDINATORS
OFF
136 SF / 12.6 m²
NURSING SVC ADMIN
OFF
164 SF / 15.2 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT OFF
158 SF / 14.7 m²
DIRS SUITE/QLT MGMT
STRATEGIC PLANNER OFF
153 SF / 14.2 m²
DIRS SUITE/QLT MGMT
DEPUTY CHIEF OF STAFF OFF
144 SF / 13.4 m²
DIRS SUITE/QLT MGMT
HEALTH SYSTEM SPECIALIST
OFF
145 SF / 13.5 m²
DIRS SUITE/QLT MGMT
CHIEF PUBLIC &
CONSUMER AFFAIRS OFF
9130 199 SF / 18.5 m²
DIRS SUITE/QLT MGMT
PATIENT ADVOCATE OFF
166 SF / 15.4 m²
HEALTH SYSTEMS
SPECIALIST OFF
149 SF / 13.8 m²
HEALTH SYSTEMS
SPECIALIST OFF
144 SF / 13.4 m²
SUPERVISOR, MEDICAL
STAFF OFF
159 SF / 14.8 m²
EEO PROGRAM
MANAGER OFF
170 SF / 15.8 m²
HEALTH SYSTEMS
SPECIALIST OFF
159 SF / 14.8 m²
HEALTH SYSTEMS
SPECIALIST OFF
167 SF / 15.5 m²
HEALTH SYSTEMS
SPECIALIST OFF
121 SF / 11.3 m²
DIRS SUITE/QLT MGMT
OFF
86 SF / 8 m²
DIRS SUITE/QLT
MGMT
STOR
9112A
76 SF / 7 m²
UNISEX RR
LOLOTOSHO
674 SF / 62.6 m²
DIRS SUITE/QLT MGMT
CONF RM
165 SF / 15.3 m²
ADMINISTRATIVE OFFICE
148 SF / 13.7 m²
COPY/MAIL ROOM
156 SF / 14.5 m²
DIRS SUITE/QLT MGMT
OFF
9120D
175 SF / 16.2 m²
KITCHEN
17 SF / 1.6 m²
DIRS SUITE/QLT MGMT
CLO
9123A
145 SF / 13.5 m²
WAITING ROOM
55 SF / 5.1 m²
COMMON
ELECTRO MECH
234 SF / 21.7 m²
DIRS SUITE/QLT MGMT
OFF
9120A
257 SF / 23.9 m²
DIRS SUITE/QLT MGMT
CHIEF OF STAFF
9120C 472 SF / 43.9 m²
DIRS SUITE/QLT MGMT
DIR
9120B
351 SF / 32.6 m²
DIRS SUITE/QLT
MGMT
SUITE
312 SF / 29 m²
DIRS SUITE/QLT MGMT
ADMINISTRATIVE
OFFICER HIGH
RELIABILITY OFFICER
POLICY COORDINATOR
SAFE PATIENT HANDLING
COORDINATOR OFF
318 SF / 29.6 m²
DIRS SUITE/QLT MGMT
MEDICAL STAFF OFF
158 SF / 14.7 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT
ASSISTANT CHIEF OFF
191 SF / 17.8 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT
DIRECTOR OFF
9219122 SF / 11.3 m²
DIRS SUITE/QLT
MGMT
QUALITY
MANAGEMENT
OFF
92 SF / 8.6 m²
DIRS SUITE/QLT
MGMT
QUALITY
MANAGEMENT OFF
32 SF / 3 m²
DIRS SUITE/QLT MGMT
CLO
108 SF / 10 m²
WOMENS RESTROOM
157 SF / 14.6 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT
PERFORMANCE IMPROVEMENT
OFF
209 SF / 19.4 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT PATIENT
SAFETY/RISK MANAGEMENT OFF
164 SF / 15.2 m²
DIRS SUITE/QLT MGMT
QUALITY MANAGEMENT PATIENT
SAFETY MANAGER OFF
205 SF / 19.1 m²
EDUCATION
EQUIP
9213A
556 SF / 51.7 m²
EDUCATION
CLASS RM
195 SF / 18.1 m²
EDUCATION
STOR
2,143 SF / 199.1 m²
EDUCATION
AUDTRM
35 SF / 3.3 m²
EDUCATION
CLO
9211A
333 SF / 31 m²
COMMON
ELECTRO MECH
64 SF / 6 m²
COMMON
TLT
9213A 58 SF / 5.4 m²
COMMON
TLT
9213B
60 SF / 5.6 m²
COMMON
VEST
29 SF / 2.7 m²
COMMON
ELECTRO MECH
43 SF / 4 m²
COMMON
HAC
359 SF / 33.4 m²
MINI
CONFERENCE
ROOM
464 SF / 43.1 m²
COMMON
ELECTRO MECH
169 SF / 15.7 m²
MENS RESTROOM
LOLOTOSHO
1,265 SF / 117.5 m²
DIRS SUITE/QLT MGMT
CORR
RCC919R
29 SF / 2.7 m²
COMMON
ELECTROMECH
93 SF / 8.6 m²
COMMON
ELECTRO MECH
113 SF / 10.5 m²
COMMON
ELECTRO MECH
9304E
34 SF / 3.2 m²
NURSING SVC
ADMIN
MAIL RM
9304A8 SF / 0.8 m²
COMMON
ELECTROMECH
9305A
45 SF / 4.2 m²
COMMON
VEST
9304D
964 SF / 89.5 m²
COMMON
CORR
RCC920R
31 SF / 2.9 m²
COMMON
ELECTROMECH
99 SF / 9.2 m²
VERTICAL SPACE
ELEV 2
RCC911R
140 SF / 13 m²
VERTICAL SPACE
ELEV 3
RCC910R
235 SF / 21.8 m²
VERTICAL SPACE
STAIR-1
RCC902R
11 SF / 1 m²
VERTICAL SPACE
CHASE
RCC901C
148 SF / 13.8 m²
WOMENS RESTROOM
LOLOTOSHO
246 SF / 22.8 m²
VERTICAL SPACE
STAIR
RCC905R
122 SF / 11.3 m²
VERTICAL SPACE
ELEV 5
RCC908R
8 SF / 0.7 m²
VERTICAL SPACE
CHASE
RCC902C
13 SF / 1.2 m²
VERTICAL SPACE
CHASE
RCC903C
307 SF / 28.5 m²
NURSING SVC
ADMIN
CORR
RCC921R
300 SF / 27.8 m²
COMMON
CORR
RCC922R
21 SF / 2 m²
COMMON
ELECTRO MECH
204 SF / 19 m²
PUBLIC AFFAIRS OFF
177 SF / 16.5 m²
VERTICAL SPACE
STAIR-11
RCC901R
91 SF / 8.4 m²
VERTICAL SPACE
ELEV 18
RCC912R
91 SF / 8.5 m²
VERTICAL SPACE
ELEV 17
RCC913R
91 SF / 8.4 m²
VERTICAL SPACE
ELEV 16
RCC914R
91 SF / 8.4 m²
VERTICAL SPACE
ELEV 15
RCC915R
86 SF / 8 m²
VERTICAL SPACE
ELEV 1
RCC916R
1,372 SF / 127.5 m²
COMMON
CORR
RCC923R
817 SF / 75.9 m²
COMMON
CORR
RCC924R
103 SF / 9.6 m²
VERTICAL SPACE
STAIR
RCC904R
314 SF / 29.1 m²
VERTICAL SPACE
STAIR NO 03
RCC903R
131 SF / 12.2 m²
COMMON
CORR
RCC925R
51 SF / 4.7 m²
VERTICAL SPACE
CHASE
RCC904C
51 SF / 4.7 m²
VERTICAL SPACE
CHASE
RCC905C
384 SF / 35.6 m²
COMMON
CHASE
RCC906C
17 SF / 1.6 m²
VERTICAL SPACE
CHASE
RCC907C
15 SF / 1.4 m²
VERTICAL SPACE
CHASE
RCC908C
27 SF / 2.6 m²
VERTICAL SPACE
CHASE
RCC909C
25 SF / 2.3 m²
VERTICAL SPACE
CHASE
RCC910C
22 SF / 2.1 m²
VERTICAL SPACE
CHASE
RCC911C
13 SF / 1.2 m²
COMMON
CHASE
RCC912C
26 SF / 2.4 m²
VERTICAL SPACE
CHASE
RCC913C
23 SF / 2.1 m²
VERTICAL SPACE
CHASE
RCC914C
8 SF / 0.8 m²
VERTICAL SPACE
CHASE
RCC915C
46 SF / 4.3 m²
VERTICAL SPACE
DUMBWAITER
RCC917R
71 SF / 6.6 m²
COMMON
CORR
RCC918R
44 SF / 4 m²
VERTICAL SPACE
CHASE
RCC916C
61 SF / 5.7 m²
VERTICAL SPACE
CHASE
RCC917C
16 SF / 1.5 m²
VERTICAL SPACE
CHASE
RCC918C
95 SF / 8.8 m²
VERTICAL SPACE
ELEV 4
RCC909R
22 SF / 2.1 m²
STORAGE
CLO
20 SF / 1.8 m²
COMMON
CLO
9124A
260 SF / 24.2 m²
DIRS SUITE/QLT MGMT
SEC Y
RCC906R
257 SF / 23.9 m²
DIRS SUITE/QLT MGMT
OPEN OFF
RCC907R
TR1
152 SF
308-4BG-A
310-TSM-A
107-SMT-F
A1
315-2G-A
SCALE: 1/16" = 1'-0"F1 9TH FLOOR PLAN LEVEL
VA Medical Center 7010 19th St. S.
Birmingham, Alabama AET Project No. P-0013087Date: 7/11/2022
Floor 09 Asbestos and Lead Sample Locations
Figure
File: X:\AMERICAN\ALABAMA\Birmingham_AL\VA_MedicalCenter\Drawings\AE109_Level_9.dwg PO 17938-1640
Legend Asbestos or Lead Sample
Positive Material
TELECOM ROOM LEGEND
EXISTING TR UPGRADED
PROPOSED NEW CABINET/TR/MCR LOCATION
ROOM CONVERTED TO FACILITY'S USE
PROPOSED EXPANSION TO TR
A1 Asbestos containing black floor tile mastic located beneath the 2" gray ceramic floor tiles.
If renovation activities will result in impacting the asbestos black mastic, remove the 2" gray ceramic floor tile and associated asbestos black mastic using manual means within a negative pressure enclosure, 24 SF. Otherwise, protect as necessary.
AET Project No. P-0013087
Appendix A Explanation of Tables
Appendix A - TABLE FORMAT EXPLANATION
The field data and the laboratory results are presented in the following tabular format:
Appendix B: Material Identification Inventory
- A room by room inventory of material types, quantity, conditions and potential for future disturbance.
Appendix C: Material Sample Analysis
- Indicates the location of bulk sample collection, material description and approximate percentage and type of fibers present.
AET Project No. P-0013087 Page 1 of 6
MATERIAL IDENTIFICATION INVENTORY KEY
Floor, Location, Room – The floor, location, and room refers to where the material was located.
Material Code (Mat'l Code) - Asbestos-containing materials are categorized into three main types:
1) Surfacing Material (S): Material in a building that is sprayed-on, troweled-on, or otherwise applied to surfaces.
2) Thermal System Insulation (T): Material applied to pipes, fittings, tanks, ducts, etc., to prevent heat loss or gain or serve as condensation control.
3) Miscellaneous Material (M): Material on interior structural components, structural members or fixtures, but not including surfacing materials and thermal insulators (e.g., floor and ceiling tiles).
Material Identification - Description of the material found in the location. (NOTE: Pipe diameters are approximate, outside diameters of the insulating materials).
Asbestos Content - This column specifies whether or not the bulk sample, or referenced bulk sample, for the described material tested contains >1% asbestos. ND means "No Asbestos Detected", NS means “Material Is Not Suspect”, PRE means “Presumed Asbestos-Containing Material”; NT means “Not Tested”. TR means “Trace” (trace = <1%).
Reference Sample Number - The sample number refers to the number assigned to the set of samples collected for the homogeneous material described (refer to Appendix C).
Quantity - The amount of material present. The parameters of each quantity expressed as follows:
1) Square Feet (SF)
2) Linear Feet (LF)
3) Each (EA)
Physical Assessment - This column is divided into two sections describing the condition of the material at the time of the survey.
The first column expressed the friability of the material as follows:
1) Friable (F) - The material can be pulverized and reduced to a powder by manual pressure when dry; this could include damaged non-friable materials.
2) Non-Friable (N) - The material can not be crumbled using hand pressure.
AET Project No. P-0013087 Page 2 of 6
The second column expressed the conditions of the material at the time of the survey as follows:
N - Not Damaged D - Damaged, the material has deteriorated or sustained physical injury such that it is not intact, less than 25% localized damage or less than 10% overall damage.
S - Significantly Damaged, the damage is extensive and severe, the asbestos-containing material has sustained greater than 25% localized damage or greater than 10% overall damage.
Damage Potential - This is a group of four columns that address the potential for the material to be disturbed/damaged in the future as follows:
L - Low potential for damage M - Moderate potential for damage H - High potential for damage or significant damage
1) Air Erosion (Air): The potential for air erosion to a material is determined by the movement of air in the area of the material and the relationship between the friability of the material and its location in respect to air plenums and air streams.
2) Vibrational Damage (Vib): This type of damage potential is determined by the presence of sounds, motors, mechanical equipment or other vibrational disturbances.
3) Accessibility (Acc): This column indicates the general use patterns of the area and the potential for contact with the material abbreviated as follows:
L - accessed less than once per month M - routine access by Operations and Maintenance Workers, between once per week to once per month H - generally accessible, routine contact by any building occupant, access more than once per week
AET Project No. P-0013087 Page 3 of 6
MATERIAL SAMPLE ANALYSIS KEY
CHAIN OF CUSTODY
Sample Numbers: The sample number refers to the number assigned to the set of samples taken from a single homogeneous material. The letter following the number identifies samples individually within a homogeneous sample series (e.g. "A", "B", and "C" for three samples of one floor tile type).
Description: This column is a written description of the material that was sampled.
Notes – The floor, location, and room refers to where the material was located.
Sample Type : Bulk samples are identified by the letter B.
LAB RESULTS: ASBESTOS PLM REPORT: METHOD 600/R-93-116
Location: Represents the sample number and material description from the Chain of Custody.
Percent and Type Asbestos: This is a detailed breakdown of approximate percentage and mineral species of asbestos found during bulk sample analysis.
Percent and Type Non-Asbestos and Percent Non-Fibrous Constituents: Listing of approximate percentage of the remaining.
AET Project No. P-0013087 Page 4 of 6
ASBESTOS BUILDING SURVEY METHODS
The asbestos survey was conducted in accordance with 29CFR1926.1101, 40 CFR Part 61 and state or local requirements. All surveys are conducted by accredited inspectors.
The asbestos survey included identifying friable and non-friable, asbestos-containing building materials (ACBM), on an area-by-area basis, assessment of friability, current condition and potential for future disturbance of the material, an estimate of the amount of ACBM, and an overall condition rating of the material.
AET identified and categorized suspect materials into three groups: 1) thermal system insulation (T) including pipe, HVAC insulation and fitting insulation; 2) sprayed-on or troweled-on surfacing material (S) including acoustical plaster, soundproofing, fireproofing, and decorative materials; and 3) miscellaneous materials (M) including ceiling tile and floor tile.
The inspector performed a visual estimation of the quantity of asbestos-containing materials and the current condition of these materials in all accessible areas. Factors included in the condition assessment are adhesion of the material to the underlying substrate, deterioration of the outer covering, delamination, contact damage, and materials disintegration.
Friability and potential for future damage of asbestos materials was also assessed by the inspector. Damage potential was evaluated by observation of conditions most likely to result in disturbance of asbestos-containing materials. These conditions are:
Air Erosion -- A direct air stream moving across the material erodes the material, thereby creating airborne fibers. The potential for air erosion is determined by the relationship between the friability of the material and its location in respect to air plenums and air streams.
Vibrational Damage - determined by the presence of noise, physical movement and mechanical vibrations, which can create ambient fiber release.
Accessibility - If the material can be reached, it is accessible and subject to accidental or intentional contact damage.
Bulk samples of suspect materials were collected in a random and unbiased manner.
Representative bulk samples of suspect materials were collected to determine the extent of ACBM present throughout the building. Sampling was completed in accordance with
40CFR763 (AHERA).
Sampling procedures utilized by the accredited inspector minimized fiber dispersal and conformed with applicable regulations. Suspect asbestos-containing materials were be analyzed by a NVLAP accredited laboratory using the Environmental Protection Agency (EPA) recommended polarized light microscopy (PLM) with dispersion staining analytical technique.
AET Project No. P-0013087 Page 5 of 6
The Environmental Protection Agency (EPA) requires that any sample with an asbestos content estimated to be less than 10 percent by a method other than point counting, such as visual estimation, shall be repeated using the point counting technique with PLM. However, if the laboratory detects asbestos in the samples and estimates the amount by visual estimation to be less than 10 percent, the owner or operator of the building may elect to treat the material as asbestos-containing. A sample in which no asbestos is detected does not require repeat analysis using point counting techniques with PLM. Samples analyzed for this survey with values less than 10 percent have not been point counted and have been assumed to contain asbestos greater than 1 percent.
AET Project No. P-0013087 Page 6 of 6
Appendix B Material Identification and Inventory
Appendix B - Material Identification Inventory Report
Area Location Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Basement
B103C
201 0-4 Fiberglass Pipe Insulation
MC Multiple Colors
T NS 7 7
Notes: Located throughout the building.
Friable
Basement
B103C
202 4-8 Fiberglass Pipe Insulation
MC Multiple Colors
T NS 0 NA
Notes: Located throughout the building.
Non-Friable
Basement
B103C
203 8-12 Fiberglass Pipe Insulation
MC Multiple Colors
T NS 7 7
Notes: Located throughout the building.
Friable
Basement
B103C
246 0-4 Fittings on Fiberglass Line
MC Multiple Colors
T NS 0 NA
Notes: Located throughout the building. Fibeglass fittings.
Non-Friable
Basement
B103C
247 4-8 Fittings on Fiberglass Line
MC Multiple Colors
T NS 0 NA
Notes: Located throughout the building. Fibeglass fittings.
Non-Friable
Page 1 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North St. Paul, MN 55114
AET Project No. P-0013087 Page B 1 of 15
Location Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Basement
B103C
248 8-12 Fittings on Fiberglass Line
MC Multiple Colors
T NS 0 NA
Notes: Located throughout the building. Fibeglass fittings.
Non-Friable
Basement
B103C
312 Mastic - Floor Tile
TB Tan/Black
M ND
Notes: Located in various areas throuhout the building.
Non-Friable
Basement
B103C
316 Concrete
FWC Floors/Walls/Ceilings
M NS 0 NA
Notes: Located throughoutthe building.
Non-Friable
Basement
B103J
308 Base Cove & Mastic
4M 4" Maroon
M ND
Notes: Located in select areas of the building.
Non-Friable
Basement
B103J
363 Epoxy Flooring
BL Blue
M ND
Notes: Located in select areas of the basement.
Non-Friable
Floor 01
107 Decorative Wall Texture
SMT Smooth
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Page 2 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 2 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 01
251 Blown-in Insulation
W White
T ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 01
234 Duct Insulation
WFG White Fiberglass
T ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 01
104 Spray Applied Fireproofing
G Gray
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 01
321 Caulk
C Clear
M ND
Notes: Located throughout the building.
Non-Friable
Floor 01
321 Caulk
PF Pink Fire
M ND
Notes: Located throughout the building.
Non-Friable
Floor 01
107 Decorative Wall Texture
SMT Smooth
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Page 3 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 3 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 01
321 Caulk
YF Yellow Fire
M ND
Notes: Located throughout the building.
Non-Friable
Floor 01
315 Ceramic Tile
12T 12" Tan
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 01
201 0-4 Fiberglass Pipe Insulation
BR Brown
T ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 01
242 0-4 Foam Pipe Insulation
MC Multiple Colors
T NS 0 NA
Notes: Located throughout the building.
Non-Friable
Floor 01
310 12x12 Floor Tile & Mastic
CBRS Cream w/ Brown Streaks
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 02
321 Caulk
DBRFC Dark Brown Fire Caulk
M ND
Notes: Located throughout the building.
Non-Friable
Page 4 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 4 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 02
355 Terra Cotta Blocks
VOT Variations of Tan
M NS 80 SF 0 NA
Notes: Located thoughout the building. The terra cotta blocks in this room ONLY, were found to contain lead above the regulated limit of 1.0 milligram per square centimeter (mg/cm2).
Non-Friable
Floor 02
2510/2127
302 2x2 Ceiling Tile
PHBW Pinhole Birdwing
M ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 02
2510/2127
309 Mastic - Carpet
GR Green
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 02
2510/2127
321 Caulk
WD White Duct
M ND
Notes: Located throughout the building.
Non-Friable
Floor 02
310 12x12 Floor Tile & Mastic
T Tan
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 02
530 Odd Sized Vinyl Floor Tile
BRB Brown Board
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Page 5 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 5 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 02
2714A
234 Duct Insulation
FG Fiberglass
T NS 0 NA
Notes: Located thoughout the building.
Non-Friable
Floor 02
2714A
310 12x12 Floor Tile & Mastic
TBRS Tan w/ Brown Streaks
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 02
310 12x12 Floor Tile & Mastic
WGRS White w/ Green Streaks
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 03
321 Caulk
BRFC Brown Fire Caulk
M ND
Notes: Located throughout the building.
Non-Friable
Floor 03
430 Tar
BAC Black Above Ceiling
M YES 12 SF
Notes: Located in various areas thoughout the building. Located specifically in Ground Floor Room G516 (48 SF), Floor 03 Room 3314 (12 SF), Room 3435 (30 SF), and Room 3436 (30 SF) for an approximate total of 120 SF.
Non-Friable
Floor 03
104 Spray Applied Fireproofing
G Gray
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Page 6 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 6 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 03
308 Base Cove & Mastic
6B 6" Black
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 03
509 Adhesive
BRF Black Raised Floor
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 03
104 Spray Applied Fireproofing
G Gray
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 03
302 2x2 Ceiling Tile
PHSS Pinhole Small Hole
M ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 03
308 Base Cove & Mastic
4AG 4" Army Green
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Floor 03
321 Caulk
RF Red Fire
M ND
Notes: Located throughout the building.
Non-Friable
Page 7 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 7 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 03
430 Tar
BAC Black Above Ceiling
M YES 30 SF
Notes: Located in various areas thoughout the building. Located specifically in Ground Floor Room G516 (48 SF), Floor 03 Room 3314 (12 SF), Room 3435 (30 SF), and Room 3436 (30 SF) for an approximate total of 120 SF.
Non-Friable
Floor 03
302 2x2 Ceiling Tile
MHLF Medium Hole Linear Fissure
M ND 7 7
Notes: Located in select areas throughout the building.
Friable
Floor 03
305 Sheetrock & Taping Compound
WC Walls and Ceilings
M ND 7 7
Notes: Located thoughout the building.
Friable
Floor 03
308 Base Cove & Mastic
4B 4" Black
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
308 Base Cove & Mastic
4T 4" Tan
M ND
Notes: Located in select areas throughout the building.
Non-Friable
Page 8 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 8 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 03
308 Base Cove & Mastic
6T 6" Tan
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
310 12x12 Floor Tile & Mastic
TM Tan Mottled
M ND 0 NA
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
310 12x12 Floor Tile & Mastic
WCF White Confetti
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
321 Caulk
W White
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
430 Tar
BAC Black Above Ceiling
M YES 30 SF
Notes: Located in various areas thoughout the building. Located specifically in Ground Floor Room G516 (48 SF), Floor 03 Room 3314 (12 SF), Room 3435 (30 SF), and Room 3436 (30 SF) for an approximate total of 120 SF.
Non-Friable
Floor 03
502 Sink Undercoating
B Black
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Page 9 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 9 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 03
308 Base Cove & Mastic
4G 4" Gray
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
3711A
310 12x12 Floor Tile & Mastic
WBGS White w/ Beige Streaks
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
302 2x2 Ceiling Tile
PHF Pinhole Fissure
M ND 7 7
Notes: Located in various areas thoughout the building.
Friable
Floor 03
310 12x12 Floor Tile & Mastic
WBRS White w/ Blue & Red Streaks
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 03
321 Caulk
GD Gray Duct
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
308 Base Cove & Mastic
6G 6" Gray
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Page 10 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 10 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 04
308 Base Cove & Mastic
4BRD 4" Brown Decorative
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
321 Caulk
TD Tan Duct
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
530 Odd Sized Vinyl Floor Tile
4BRB 4" Brown Board
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
308 Base Cove & Mastic
4BR 4" Brown
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
310 12x12 Floor Tile & Mastic
WBS White w/ Black Specks
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
313 Sheet Floor & Mastic
Y Yellow
M ND 7 7
Notes: Located in various areas thoughout the building.
Friable
Page 11 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 11 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 04
315 Ceramic Tile
2T 2" Tan
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
308 Base Cove & Mastic
4THB 4" Thick Black
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
530 Odd Sized Vinyl Floor Tile
16T 16" Tan
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 04
303 2x4 Ceiling Tile
PHF Pinhole Fissure
M ND 7 7
Notes: Located in various areas thoughout the building.
Friable
Floor 04
310 12x12 Floor Tile & Mastic
CRGS Cream w/ Gray Streaks
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 06
308 Base Cove & Mastic
6GR 6" Green
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Page 12 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 12 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 06
525 Laboratory Counters
B Black
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 06
6332A
321 Caulk
B Black
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 06
322 Steel
CLG Ceiling
M NS 0 NA
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 08
315 Ceramic Tile
4LBL 4" Light Blue
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 08
315 Ceramic Tile
4GR 4" Green
M ND 120 SF
Notes: Located in various areas thoughout the building. The glazing on the tile was found to contain lead above the regulated limit of 1.0 milligram per square centimeter (mg/cm2).
Non-Friable
Floor 09
107 Decorative Wall Texture
SMT Smooth
S ND 7 7
Notes: Located in select areas throughout the building.
Friable
Page 13 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 13 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Floor 09
308 Base Cove & Mastic
4BG 4" Beige
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Floor 09
315 Ceramic Tile
2G 2" Gray
M YES 24 SF
Notes: Located in various areas thoughout the building. There is black floor tile mastic beneath the ceramic tile that was found to contain asbestos.
Non-Friable
Floor 09
310 12x12 Floor Tile & Mastic
TSM Tan Small Mottled
M ND 0 NA
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G111G
308 Base Cove & Mastic
6BR 6" Brown
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G111G
309 Mastic - Carpet
C Clear
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G114B
302 2x2 Ceiling Tile
MHWF Medium Hole Wide Fissure
M ND 7 7
Notes: Located in various areas thoughout the building.
Friable
Page 14 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 14 of 15
Room Number
Material
ID
Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name: GDM Project Number: P-0013087 Project Manager: Bruce A. Boehm Carlson
Building Number: 7010 Building Name VA Medical Center Building Address 1: 7010 19th St. S.
Sample Set Name: 1 Building Address 2:
City, State Zip: Birmingham, AL 35233
Lead Paint
Ground Floor
G114B
308 Base Cove & Mastic
4LGR 4" Light Green
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G114B
310 12x12 Floor Tile & Mastic
WLC White Large Confetti
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G516
302 2x2 Ceiling Tile
SSR Smooth Sheetrock
M ND 7 7
Notes: Located in various areas thoughout the building.
Friable
Ground Floor
G516
315 Ceramic Tile
MBRB Multi-Brown Brick
M ND
Notes: Located in various areas thoughout the building.
Non-Friable
Ground Floor
G516
430 Tar
BAC Black Above Ceiling
M YES 48 SF
Notes: Located in various areas thoughout the building. Located specifically in Ground Floor Room G516 (48 SF), Floor 03 Room 3314 (12 SF), Room 3435 (30 SF), and Room 3436 (30 SF) for an approximate total of 120 SF.
Non-Friable
Page 15 of 15Wednesday, July 20, 2022
2:57:28 PM
American Engineering Testing, Inc.
550 Cleveland Avenue North
AET Project No. P-0013087 Page B 15 of 15
Appendix C Asbestos Laboratory Analytical Results
Approved by:
A…